Loading...
HomeMy WebLinkAbout2232 RUTHERFORD RD; ; AS050256; Permit5/22/25, 9:59 AM AS050256 Permit Data City of Carlsbad Sprinkler Permit 2232 RUTHERFORD Job Address: RD Permit Type: SPRINK Parcel No: 2120612600 Lot #: 0 Permit No: AS050256 Status: ISSUED Applied 12/21/2005 Approved: 12/22/2005 Reference No.: Issued: 12/22/2005 PC #: Inspector: Project Title: SYNERGEYES FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 Owner: RUTHERFORD ROAD LLC C/O STONERIDGE CAPITAL PARTNERS 4350 VON KARMAN AVE #400 NEWPORT BEACH CA Fees ($) Balance ($) 120 0 120 0 about:blank 1/1 many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to VV (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- cure rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. X ctaulicr V27, K5.6 Models V2703, V2704, V2707 and V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response PRODUCT DESCRIPTION These Model V27 standard spray sprinklers are designed to produce a 4, hemispherical spray pat- tern for standard commer- cial applications. They are v2701 V2708 available with either stan- Recessed dard or quick response Pendent bulbs. The design incorpo- () UL () rates state-of-the-art, heat S <FM responsive, frangible glass - see Victaulic bulb design (standard or publication • ' quick response) for prompt, V707details. V2708 precise operation. The die cast frame is more streamlined and attractive than traditional sand cast Pendent frames. It is cast with a V2733 hex-shaped wrench boss to V2734 I allow easy tightening from Upright TECHNICAL SPECIFICATIONS Models: V2703. V2704, V2707 V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 (13 mm) K-Factor: 5.6 Imp. (8,1 SI.") Nominal Thread Size: 1/2 NPT (15 nun) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Upright Deflector: Bronze per UNS C22000 Pendent Deflector: Bronze per UNS CS 1000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5.0 mm U Quick Response: 3.0 mm Load Screw: Bronze per UNS C65 100 Pip Cap: Bronze per UNS C65 IOU Spring: Beryllium nickel Seal: Teflon* tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: U Open End: V27 U Recessed: V38. V38-3 U Socket: V27 Finishes: U Plain brass U Chrome -plated U White painted** U Custom painted* U Lead** 155, 200, 2865R Only: U Wax 13 Wax over lead* For cabinets and other accesso- ries refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. For K-Factor Men pressure is mea- sured in Bar, multiply SA. units by 10.0. Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance in all configurations. VICTAULIC5 IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800.PICK.VIC (1-800-742.5842) Phone: 905.884-7444 Phone: 32-9.381.1500 Phone: 610.559.3300 Phone: 65.6235-3035 Fax: 610.250.8817 Fax: 905-884.9774 Fax: 32.9.380-4438 Fax: 610.559.3608 Fax: 65.6235.0535 e-mail:pickvic@viclxulic.com e-mail: viCCanada@victaulic.com e-mail: viceuro@victaulic.be e-mail: vical@viclaulic.com e-mail: vicapofvictaulic.com 2544 Rev.O 8/03 40 Registered Trademark of ViCladiC • 0 Copyright 2003 Victaulic Printed in U.S.A. APPROVALSILISTINGS Nominal Approved Temperature Ratings °F/°C Orifice Size K-Factor Inches Imperial Deflector Model millimeters S.L.Response Type UL FM ULC NYC/MEAt CSFM § 1h 5.6 135.360 135-360 135-360 135-360 135-360 V2703 13 8.1 Standard upright 57-182 57-182 57- 182 57-182 57- 182 ½ 5.6 135-360 135-360 135-360 135-360 135-360 V2707 13 8,1 Standard Pendent 57-182 57-182 57-182 57-182 57-182 1h 5.6 Recessed Pendent 135-360 135-200 135-360 135-360 135-360 V2707 13 8,1 Standard UptowAdjustment 57-182 57-93 1 57-182 57-182 57-182 1h 5.6 135-286 135-286 135-286 135-286 135-286 V2704 13 8,1 Quick Upright 57-141 57-141 57-141 57-141 57-141 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2708 13 8,1 Quick Pendant 57-141 57- 141 57-141 57-141 57 -141 1h 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 135-200 V2708 13 8,1 Quick ½ Up to ' Adjustment 57-93 57-93 57-93 57-93 57-93 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 V2708 13 8.1 Quick Up to %' Adjustment 5793 No 5793 1 5793 Listings and approval as of printing. 0 All are approved open, except for areas designated 'No'. For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. 1 MEA#62-99-E. §CSFM #7690-0531:112 RATINGS All glass bulbs are rated for temperatures from 67°F (-55°C) up to those shown in adjacent table. Temperature - FIC Sprinkler Victaulic Nominal Maximum Glass Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary ' C 155 100 68 38 Red Intermediate E 175 150 79 65 Yellow Intermediate F 200 93 150 65 Green High J 286 141 225 107 Blue Extra High I K 360 182 300 149 Purple - I M Open : No Bulb 4 Standard response only. All are approved open, except for areas designated 'No". 150/65 if wax coated. - ORDERING INFORMATION Please specify the following when ordering: U Sprinkler Model Number U K-Factor U Sprinkler Finish U Style U Thread Size U Escutcheon Finish U Temperature Rating U Quantity U Wrench Model Number Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. . 0 • Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. It you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.10-2 DIMENSIONS (6( 1W 2W (41 mm) (60 mm) I 17Aa (37 mm) (25 mm) Standard Pendant - V2707. V2708 Standard Upright - V2703, V2704 - VLIUI, fll VU (Drawing not to scale) 2W (60 mm) Max. Hole Min. Hole (24 m m) :±: I MAXIMUM RECESS 2%r (75 mm) MAXIMUM EXTENSION 44" Adjustment Recessed - V2707, V2708 (Drawing not to scale) AVAILABLE WRENCHES V27 Socket V38 or V38-3 Recessed V27 Open End V2707, V2708 Pendent / / of V2707, V2708 Recessed Pendent 01, - V2703. V2704 Upright - / / 40.10-3 - - m m - -s--- m N , N _--_ - Ni IT) \ S -- -'- 10' 3,0 m 8 2,4 6 1,8 4 1,2 2 0,6 C 7psi 48 kPa 15 psi 103 kPa 30 psi ------ 207 We DISTRIBUTION PATTERNS MODELS V2707, V2708 K5.6 STANDARD PENDENT AND RECESSED PENDENT DISTRIBUTION PATTERNS - TRAJECTORY 4 10' 3,0 m 8' 2,4 m 6' 1,8 m 4' 1,2 m 2' 0,6 m 7psi 46 kPa 15 psi 103 kPa 30 psi ------- 207 kPa 0 2' 4' 6' 8' 10' 12' 14' 0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m MODELS V2703, V2704 1(5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY 0,6 m 1,2 m 1,8 m 2,4 m 3,0m 3,7 m 4,3 m 4,9 m NOTES: Data shown is approximate and can vary clue to differences in installation. These graphs illustrate approximate trajectories. floor-weulitig. and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer io the appropriate NFPA National Fire Code and the authority having jurisdiction for specific information regarding obstructions. spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings. Approvals and War- rant ies. All patterns are symmetrical to the centerline of tile waterway. I 1 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. Au products to be installed in accordance with current Victaulic installation/assembly instructions, Viclaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. DEoI 13-84 INSTALLATION OF SPRINKLER SYSTEMS Tab1ë .7-2.32.2 Discharge Criteria for Miscellaneous Storage and Storage 12 ft (3.7 m) or Less in Height,' Commodity Classes I through IV Commodity Classification Palletized and Bin Box Rack I OH-1 OH-1 II up to 8 ft (2.4 m) OH-1 OH-1 II over 8 ft (2.4 m) up to 12 ft (3.6 m) OH-2 OH-2 III OH-2 OH-2 [V up to lOft (3m) OH-2 OH-2 I N over 10 ft (3 m) to 12 ft (3.6 m) OH-2, . EH-i Group A Plastics Stored on Racks Cartoned Exposed Storage Maximum Height Building Height Solid Expanded Solid Expanded Up to 5 ft No limit OH-2 OH-2 OH-2 OH-2 Over 5 ft to 10 ft 15 ft EH-1 EH-1 . EH-2 EH-2 Over 5 ft to 10 ft 20 ft EH-2 EH-2 EH-2 OH-2 +1 level in-rack5 Over 10 ft o 12 ft 17 ft H-2' EH-22 EH-22 EH-22 Over 10 ft to 12 ft No limit OH-2 OH-2 OH-2 OH-2 +1 level in-rack5 +1 level in-rack5 +1 level in-rack5 +1 level in-rack5 Group A Plastics Solid Piled, Palletized, Bin-Box, or Shelf Storage Cartoned Exposed Storage Maximum Height Building Height Solid Expanded Solid Expanded Up to 5 ft No limit OH-2 ' OH.2 OH-2 OH-2 S.y Over 5 ft to io ft 15 ft EH-1 'EH-1 EH-2 EH-2 Over 5 ft to 10 ft 20 ft EH-2 EH-2 EH-2 — Over 5 ft to 8 ft No limit -. . — EH-2 Over 10 ft to 12 ft 17 ft EH-2. EH-2 EH-2 EH-2 Over 10 ft to 12 ft 27 ft EH-2 . ' EH-2; — — Miscellaneous Tire Storages . Piling Methods Height of Storage Occupancy Group On floor, on side 5 ft to 12 ft EH-1 On floor, on tread or on side To 5 ft OH-2 Single, double, or multirow racks on To 5 ft OH-2 tread or on side .( ' Single row rack, portable, on tread or on 5ft to 12 ft: EH-1 side . . a.fl Single row rack, fixed, on tread or on 5 ft to 12 ft EH-1 or OH-2 plus one level of in-rack side .. ' . sprinklers 1999 Edition 13-132 INSTALLATION OF SPRINKLER SYSTEMS 7.9.8.2 Columns within Rubber Tire Storage. Where fireproof- ing is not provided, steel columns shall be protected as follows: Storage exceeding 15 ft through 20 ft (4.6 m through 6 m) in height - one sidewall sprinkler directed to one side of the column at 15-ft (4.6-rn) level Storage exceeding 20 ft (6.1 rn) in height - two sidewall sprinklers, one at the top of the column and the other at a 15-ft (4.6-rn) level, both directed to the side of the column Exception. The protection specified in 7-9.8.1(1) and (2) shall not be required where storage in fixed racks is protected by in-rack sprinklers. Table 7-9.8.1 Ceiling Sprinkler Densities for Protection of Steel Building Columns Aisle Width 4ft(1.2m) 8ft(2.4m) Commodity Class gpm/ft2 mm/mm 0.37 15.1 Il 0.44 17.9 Ill 0.49 1 20.0 IV and plastics 0.68 27.7 Note: For aisle widths of 4 ft to 8 ft (1.2 m to 2.4 m), a direct linear in- lerpolation between densities can be made. 7-10 Sprinkler System Discharge Criteria for Special Occupancy Hazards. 7-10.1 Flammable and Combustible Liquids. See NFPA 30, Flammable and Combustible Liquids Code, for sprinkler system dis- charge criteria pertaining to the protection of flammable and combustible liquids. 7-10.2 Aerosol Products. See NFPA 30B, Code for the Manufac- ture and Storage of Aerosol Products, for sprinkler system discharge criteria pertaining to the protection of aerosol products. 7-10.3 Spray Application Using Flammable or Combustible Materials. 7-10.3.1 See NFPA 33, Standard far Spray Application Using Flammable or Combustible Materials, for applicable terms not defined in Chapter 1. 7.10,3.2* Spray Areas and Mixing Rooms. The automatic sprin- kler system in spray areas and mixing rooms shall be designed for Extra Hazard (Group 2) occupancies. (33: 7-2.1) 7-10.3.3 Water supply for sprinklers shall be sufficient to supply all sprinklers likely to open in any one fire incident without depleting the available water for use in hose streams. Where sprinkler's are installed to protect spray areas and mixing rooms only, water shall be permitted to be furnished from the domestic supply, subject to the approval of the authority having jurisdic- tion and provided the domestic supply can meet the design cri- teria for extra hazard, Group 2 occupancies. (33: 7-2.3) 7-10.3.4 For spray application areas using styrene cross-linked thermoset resins (commonly known as glass fiber reinforced plastics), automatic sprinkler systems shall be designed and 1999 Edition installed for at least ordinary hazard, Group 2 occupancies. (33: 15-3) 7-10.4 Solvent Extraction Plants. 7-10.41 See NFPA 36, Standardfor Solvent Extraction Plants, for- applicable terms not defined in Chapter 1. 7.10.4.2* Sprinkler Systems. (36: 2-9) 7-10.5 Nitrate Film. 7-10.5.1 See NFPA 40, Standard for the Storage and Handling of Cellulose Nitrate Motion Picture Film, for applicable terms not defined in Chapter 1. 7-10.5.2 Where rooms containing nitrate film are required to be sprinklered per NFPA 40, the sprinkler system shall be installed in accordance with the requirements for extra hazard occupancies. (40: 3-1.2) 7-10.5.3 Sprinkler System Water Supply. Water supplies for automatic sprinklers shall be based on 20 gpm (1.26 L/sec) per sprinkler for 20 minutes for the total number of sprinklers in one vault, plus 25 percent of the sprinklers in the commu- nicating fire area. (40: 3-2.2) 7-10.6 Storage of Pyroxylin Plastic. 7-10.6.1 See NFPA 42, Codefor the Storage of Pyroxylin Plastic, for applicable terms not defined in Chapter 1. 7-10.6.2 Sprinkler System Water Supply. 7-10.6.2.1 The water supply for automatic sprinklers shall be based on the number of sprinklers liable to be affected in any fire section between fire walls or fire-resistive partitions. It shall be assumed that any one of the following numbers of sprinklers can be affected and the condition giving maximum flow used as a basis: All sprinklers in a vault All sprinklers in a tote box storeroom Three-fourths of the sprinklers in a finished-stock store- room All sprinklers in a section of an isolated storage building (42: 2-4.3.1) 7-10.6.2.2 The water supply for an automatic sprinkler system shall be based on a flow of 20 gpm (76 Lpm) per sprinkler for 20 minutes, with a minimum rate of flow of 500 gpm (1900 Lpm). Such flow shall be with an effective pressure at the top line of sprinklers of not less than 40 psi (2.8 bar). (42: 2-4,3.2) 7-10.7 Laboratories Using Chemicals./ 7-10.7.1 See NFPA 45, Standardfor Fire Protection for Laboratories Using Chemicals, for applicable terms not defined in Chapter 1. 7-10.7.2 An automatic sprinkler system, where required by Table 3-1 (a) of NFPA 45, depending on the construction of the building, the hazard class of the laboratory unit, the con- struction of the laboratory unit enclosure, and the area of the laboratory unit shall be in accordance with the following: (1) Automatic sprinkler system protection for Class A and Class B laboratories shall be in accordance with ordinary hazard, Group 2 occupancies. (2)' Automatic sprinkler system protection for Class C and Class D laboratories shall be in accordance with ordinary hazard, Group I occupancies. (45: 4-2.1.1)