many angles, reducing
assembly effort. This sprin-
kler is available in various
temperature ratings (see
chart on page 2) and fin-
ishes to meet many design
requirements.
The recessed pendent
should be utilized with a
Model V27 recessed
escutcheon which pro-
vides up to VV (19 mm) of
adjustments.
Sprinkler Operation
The operating mechanism
is a frangible glass bulb
which contains a heat
responsive liquid. During a
fire, the ambient tempera-
cure rises causing the liquid
in the bulb to expand.
When the ambient temper-
ature reaches the rated
temperature of the sprin-
kler, the bulb shatters. As a
result, the waterway is
cleared of all sealing parts
and water is discharged
towards the deflector. The
deflector is designed to dis-
tribute the water in a pat-
tern that is most effective
in controlling the fire.
Coverage
For coverage area and
sprinkler placement, refer
to NFPA 13 standards.
X ctaulicr V27, K5.6
Models V2703, V2704, V2707 and V2708
Standard Spray
Upright, Pendent and Recessed Pendent
Standard and Quick Response
PRODUCT DESCRIPTION
These Model V27 standard
spray sprinklers are
designed to produce a 4, hemispherical spray pat-
tern for standard commer-
cial applications. They are v2701
V2708 available with either stan-
Recessed dard or quick response
Pendent bulbs. The design incorpo-
() UL () rates state-of-the-art, heat
S <FM responsive, frangible glass
- see Victaulic bulb design (standard or
publication • ' quick response) for prompt, V707details.
V2708 precise operation.
The die cast frame is more
streamlined and attractive
than traditional sand cast
Pendent frames. It is cast with a
V2733 hex-shaped wrench boss to
V2734 I allow easy tightening from
Upright
TECHNICAL SPECIFICATIONS
Models: V2703. V2704, V2707
V2708
Style: Pendent, Upright or
Recessed Pendent
Nominal Orifice Size:
1/2 (13 mm)
K-Factor: 5.6 Imp. (8,1 SI.")
Nominal Thread Size:
1/2 NPT (15 nun)
Max. Working Pressure:
175 psi (1200 kPa)
Factory Hydrostatic Test:
100% @ 500 psi (3450 kPa)
Mm. Operating Pressure:
7 psi (48 kPa)
Temperature Rating: See
chart on page 2.
MATERIAL
SPECIFICATIONS
Upright Deflector:
Bronze per UNS C22000
Pendent Deflector:
Bronze per UNS CS 1000
Bulb: Glass with glycerin solu-
tion.
Bulb Nominal Diameter:
U Standard: 5.0 mm
U Quick Response: 3.0 mm
Load Screw: Bronze per UNS
C65 100
Pip Cap: Bronze per UNS
C65 IOU
Spring: Beryllium nickel
Seal: Teflon* tape
Frame: Die cast brass 65-30
Lodgement Spring:
Stainless steel per UNS S30200
ACCESSORIES
Installation Wrench:
U Open End: V27
U Recessed: V38. V38-3
U Socket: V27
Finishes:
U Plain brass
U Chrome -plated
U White painted**
U Custom painted*
U Lead**
155, 200, 2865R Only:
U Wax
13 Wax over lead*
For cabinets and other accesso-
ries refer to separate sheet.
NOTE: Weather resistant recessed
escutcheons available upon request.
For K-Factor Men pressure is mea-
sured in Bar, multiply SA. units by
10.0.
Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance in all configurations.
VICTAULIC5 IS AN ISO 9001 CERTIFIED COMPANY
Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific
Phone: 1-800.PICK.VIC (1-800-742.5842) Phone: 905.884-7444 Phone: 32-9.381.1500 Phone: 610.559.3300 Phone: 65.6235-3035
Fax: 610.250.8817 Fax: 905-884.9774 Fax: 32.9.380-4438 Fax: 610.559.3608 Fax: 65.6235.0535
e-mail:pickvic@viclxulic.com e-mail: viCCanada@victaulic.com e-mail: viceuro@victaulic.be e-mail: vical@viclaulic.com e-mail: vicapofvictaulic.com
2544 Rev.O 8/03 40 Registered Trademark of ViCladiC • 0 Copyright 2003 Victaulic Printed in U.S.A.
APPROVALSILISTINGS
Nominal Approved Temperature Ratings °F/°C
Orifice Size K-Factor
Inches Imperial Deflector
Model millimeters S.L.Response Type UL FM ULC NYC/MEAt CSFM §
1h 5.6 135.360 135-360 135-360 135-360 135-360
V2703 13 8.1 Standard upright 57-182 57-182 57- 182 57-182 57- 182
½ 5.6 135-360 135-360 135-360 135-360 135-360 V2707 13 8,1 Standard Pendent 57-182 57-182 57-182 57-182 57-182
1h 5.6 Recessed Pendent 135-360 135-200 135-360 135-360 135-360 V2707 13 8,1 Standard UptowAdjustment 57-182 57-93 1 57-182 57-182 57-182
1h 5.6 135-286 135-286 135-286 135-286 135-286 V2704 13 8,1 Quick Upright 57-141 57-141 57-141 57-141 57-141
½ 5.6 135-286 135-286 135-286 135-286 135-286 V2708 13 8,1 Quick Pendant 57-141 57- 141 57-141 57-141 57 -141
1h 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 135-200 V2708 13 8,1 Quick ½ Up to ' Adjustment 57-93 57-93 57-93 57-93 57-93
½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 V2708 13 8.1 Quick Up to %' Adjustment 5793 No 5793 1 5793
Listings and approval as of printing. 0 All are approved open, except for areas designated 'No'.
For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.
1 MEA#62-99-E. §CSFM #7690-0531:112
RATINGS
All glass bulbs are rated for
temperatures from 67°F
(-55°C) up to those shown
in adjacent table.
Temperature - FIC
Sprinkler Victaulic Nominal Maximum Glass
Temperature Part Temperature Ambient Temp. Bulb
Classification Identification Rating Allowed Color
Ordinary A 135
57
100
38 Orange
Ordinary ' C 155 100
68 38 Red
Intermediate E 175 150
79 65 Yellow
Intermediate F 200
93
150
65 Green
High J 286
141
225
107 Blue
Extra High I K 360
182
300
149 Purple
- I M Open : No Bulb
4 Standard response only.
All are approved open, except for areas designated 'No".
150/65 if wax coated. -
ORDERING INFORMATION
Please specify the following
when ordering: U Sprinkler Model Number U K-Factor U Sprinkler Finish
U Style U Thread Size U Escutcheon Finish
U Temperature Rating U Quantity U Wrench Model Number
Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation
of any sprinklers.
Always wear safety glasses and foot protection.
Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. . 0 • Installation rules, especially those governing obstruction, must be strictly followed.
Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed.
Failure to follow these instructions could result in serious personal injury and/or property damage.
The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the
current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional
maintenance, testing, and inspection requirements that must be followed.
It you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton,
Pennsylvania 18044-0031, 610-559-3300.
40.10-2
DIMENSIONS
(6( 1W
2W (41 mm)
(60 mm) I
17Aa
(37 mm)
(25 mm)
Standard Pendant - V2707. V2708 Standard Upright - V2703, V2704
- VLIUI, fll VU
(Drawing not to scale)
2W (60 mm)
Max. Hole
Min. Hole
(24 m
m) :±: I MAXIMUM RECESS
2%r
(75 mm)
MAXIMUM EXTENSION
44" Adjustment
Recessed - V2707, V2708
(Drawing not to scale)
AVAILABLE WRENCHES
V27
Socket
V38 or V38-3
Recessed
V27
Open End
V2707, V2708 Pendent / / of
V2707, V2708 Recessed Pendent 01, -
V2703. V2704 Upright - / /
40.10-3
- -
m
m -
-s---
m N , N
_--_ -
Ni
IT) \ S
-- -'-
10'
3,0 m
8
2,4
6
1,8
4
1,2
2
0,6
C
7psi
48 kPa
15 psi
103 kPa
30 psi ------
207 We
DISTRIBUTION PATTERNS
MODELS V2707, V2708
K5.6 STANDARD PENDENT AND RECESSED PENDENT
DISTRIBUTION PATTERNS - TRAJECTORY
4
10'
3,0 m
8'
2,4 m
6'
1,8 m
4'
1,2 m
2'
0,6 m
7psi
46 kPa
15 psi
103 kPa
30 psi -------
207 kPa
0 2' 4' 6' 8' 10' 12' 14'
0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m
MODELS V2703, V2704
1(5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY
0,6 m 1,2 m 1,8 m 2,4 m 3,0m 3,7 m 4,3 m 4,9 m
NOTES:
Data shown is approximate and can vary clue to differences in installation.
These graphs illustrate approximate trajectories. floor-weulitig. and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are
provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer io
the appropriate NFPA National Fire Code and the authority having jurisdiction for specific information regarding obstructions. spacing limitations and area of
coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings. Approvals and War-
rant ies.
All patterns are symmetrical to the centerline of tile waterway.
I 1
WARRANTY Refer to the Warranty section
of the current Price List or
contact Victaulic for details.
This product shall be manufactured by Victaulic Company. Au products to be installed in accordance with current Victaulic installation/assembly instructions,
Viclaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
DEoI
13-84 INSTALLATION OF SPRINKLER SYSTEMS
Tab1ë .7-2.32.2 Discharge Criteria for Miscellaneous Storage and Storage 12 ft (3.7 m) or Less in Height,' Commodity Classes I
through IV
Commodity Classification Palletized and Bin Box Rack
I OH-1 OH-1
II up to 8 ft (2.4 m) OH-1 OH-1
II over 8 ft (2.4 m) up to 12 ft (3.6 m) OH-2 OH-2
III OH-2 OH-2
[V up to lOft (3m) OH-2 OH-2
I N over 10 ft (3 m) to 12 ft (3.6 m) OH-2, . EH-i
Group A Plastics Stored on Racks
Cartoned Exposed Storage Maximum
Height Building Height Solid Expanded Solid Expanded
Up to 5 ft No limit OH-2 OH-2 OH-2 OH-2
Over 5 ft to 10 ft 15 ft EH-1 EH-1 . EH-2 EH-2
Over 5 ft to 10 ft 20 ft EH-2 EH-2 EH-2 OH-2
+1 level in-rack5
Over 10 ft o 12 ft 17 ft H-2' EH-22 EH-22 EH-22
Over 10 ft to 12 ft No limit OH-2 OH-2 OH-2 OH-2
+1 level in-rack5 +1 level in-rack5 +1 level in-rack5 +1 level in-rack5
Group A Plastics Solid Piled, Palletized, Bin-Box, or Shelf Storage
Cartoned Exposed Storage Maximum
Height Building Height Solid Expanded Solid Expanded
Up to 5 ft No limit OH-2 ' OH.2 OH-2 OH-2 S.y
Over 5 ft to io ft 15 ft EH-1 'EH-1 EH-2 EH-2
Over 5 ft to 10 ft 20 ft EH-2 EH-2 EH-2 —
Over 5 ft to 8 ft No limit -. . — EH-2
Over 10 ft to 12 ft 17 ft EH-2. EH-2 EH-2 EH-2
Over 10 ft to 12 ft 27 ft EH-2 . ' EH-2; — —
Miscellaneous Tire Storages .
Piling Methods Height of Storage Occupancy Group
On floor, on side 5 ft to 12 ft EH-1
On floor, on tread or on side To 5 ft OH-2
Single, double, or multirow racks on To 5 ft OH-2
tread or on side .( '
Single row rack, portable, on tread or on 5ft to 12 ft: EH-1 side . . a.fl
Single row rack, fixed, on tread or on 5 ft to 12 ft EH-1 or OH-2 plus one level of in-rack side .. ' .
sprinklers
1999 Edition
13-132 INSTALLATION OF SPRINKLER SYSTEMS
7.9.8.2 Columns within Rubber Tire Storage. Where fireproof-
ing is not provided, steel columns shall be protected as follows:
Storage exceeding 15 ft through 20 ft (4.6 m through 6 m)
in height - one sidewall sprinkler directed to one side of
the column at 15-ft (4.6-rn) level
Storage exceeding 20 ft (6.1 rn) in height - two sidewall
sprinklers, one at the top of the column and the other at a
15-ft (4.6-rn) level, both directed to the side of the column
Exception. The protection specified in 7-9.8.1(1) and (2) shall not be
required where storage in fixed racks is protected by in-rack sprinklers.
Table 7-9.8.1 Ceiling Sprinkler Densities for Protection of
Steel Building Columns
Aisle Width
4ft(1.2m) 8ft(2.4m)
Commodity Class gpm/ft2 mm/mm
0.37 15.1
Il 0.44 17.9
Ill 0.49 1 20.0
IV and plastics 0.68 27.7
Note: For aisle widths of 4 ft to 8 ft (1.2 m to 2.4 m), a direct linear in-
lerpolation between densities can be made.
7-10 Sprinkler System Discharge Criteria for Special
Occupancy Hazards.
7-10.1 Flammable and Combustible Liquids. See NFPA 30,
Flammable and Combustible Liquids Code, for sprinkler system dis-
charge criteria pertaining to the protection of flammable and
combustible liquids.
7-10.2 Aerosol Products. See NFPA 30B, Code for the Manufac-
ture and Storage of Aerosol Products, for sprinkler system discharge
criteria pertaining to the protection of aerosol products.
7-10.3 Spray Application Using Flammable or Combustible
Materials.
7-10.3.1 See NFPA 33, Standard far Spray Application Using
Flammable or Combustible Materials, for applicable terms not
defined in Chapter 1.
7.10,3.2* Spray Areas and Mixing Rooms. The automatic sprin-
kler system in spray areas and mixing rooms shall be designed
for Extra Hazard (Group 2) occupancies. (33: 7-2.1)
7-10.3.3 Water supply for sprinklers shall be sufficient to supply
all sprinklers likely to open in any one fire incident without
depleting the available water for use in hose streams. Where
sprinkler's are installed to protect spray areas and mixing rooms
only, water shall be permitted to be furnished from the domestic
supply, subject to the approval of the authority having jurisdic-
tion and provided the domestic supply can meet the design cri-
teria for extra hazard, Group 2 occupancies. (33: 7-2.3)
7-10.3.4 For spray application areas using styrene cross-linked
thermoset resins (commonly known as glass fiber reinforced
plastics), automatic sprinkler systems shall be designed and
1999 Edition
installed for at least ordinary hazard, Group 2 occupancies.
(33: 15-3)
7-10.4 Solvent Extraction Plants.
7-10.41 See NFPA 36, Standardfor Solvent Extraction Plants, for-
applicable terms not defined in Chapter 1.
7.10.4.2* Sprinkler Systems. (36: 2-9)
7-10.5 Nitrate Film.
7-10.5.1 See NFPA 40, Standard for the Storage and Handling of
Cellulose Nitrate Motion Picture Film, for applicable terms not
defined in Chapter 1.
7-10.5.2 Where rooms containing nitrate film are required to
be sprinklered per NFPA 40, the sprinkler system shall be
installed in accordance with the requirements for extra hazard
occupancies. (40: 3-1.2)
7-10.5.3 Sprinkler System Water Supply. Water supplies for
automatic sprinklers shall be based on 20 gpm (1.26 L/sec)
per sprinkler for 20 minutes for the total number of sprinklers
in one vault, plus 25 percent of the sprinklers in the commu-
nicating fire area. (40: 3-2.2)
7-10.6 Storage of Pyroxylin Plastic.
7-10.6.1 See NFPA 42, Codefor the Storage of Pyroxylin Plastic, for
applicable terms not defined in Chapter 1.
7-10.6.2 Sprinkler System Water Supply.
7-10.6.2.1 The water supply for automatic sprinklers shall be
based on the number of sprinklers liable to be affected in any
fire section between fire walls or fire-resistive partitions. It
shall be assumed that any one of the following numbers of
sprinklers can be affected and the condition giving maximum
flow used as a basis:
All sprinklers in a vault
All sprinklers in a tote box storeroom
Three-fourths of the sprinklers in a finished-stock store-
room
All sprinklers in a section of an isolated storage building
(42: 2-4.3.1)
7-10.6.2.2 The water supply for an automatic sprinkler system
shall be based on a flow of 20 gpm (76 Lpm) per sprinkler for
20 minutes, with a minimum rate of flow of 500 gpm (1900
Lpm). Such flow shall be with an effective pressure at the top
line of sprinklers of not less than 40 psi (2.8 bar). (42: 2-4,3.2)
7-10.7 Laboratories Using Chemicals./
7-10.7.1 See NFPA 45, Standardfor Fire Protection for Laboratories
Using Chemicals, for applicable terms not defined in Chapter 1.
7-10.7.2 An automatic sprinkler system, where required by
Table 3-1 (a) of NFPA 45, depending on the construction of
the building, the hazard class of the laboratory unit, the con-
struction of the laboratory unit enclosure, and the area of the
laboratory unit shall be in accordance with the following:
(1) Automatic sprinkler system protection for Class A and
Class B laboratories shall be in accordance with ordinary
hazard, Group 2 occupancies.
(2)' Automatic sprinkler system protection for Class C and
Class D laboratories shall be in accordance with ordinary
hazard, Group I occupancies. (45: 4-2.1.1)