Loading...
HomeMy WebLinkAbout2180 RUTHERFORD RD; ; FA150069; Permit5/22/25, 11:02AM FA150069 Permit Data City of Carlsbad Fire Alarm Permit 2180 RUTHERFORD Job Address: RD Permit Type: FALARM Parcel No: 2120702500 Lot #: 0 Reference No.: Permit No: FA150069 Status: ISSUED Applied 10/22/2015 Approved: 10/26/2015 Issued: 10/26/2015 PC #: Inspector: Project Title: CALLAWAY HQ BLDG TI REMOVE AND RELOCATE EXISTING STROBES AND HORN/STROBES AS SHOWN. IN EXISTING SPRINKLERED BLDG. REWORK EXISTING NAC CIRCUITS ON EXISTING POWER SUPPLIES. EXISTING DEVICES TO REMAIN AS IS. SYSTEM IS MONITORED BY CENTRAL STATION. Applicant: NOVA SECURITY SUITE 103 8779 COTTONWOOD AV SANTEE, CA 619-448-3007 Owner: CALLAWAY GOLF CO 2180 RUTHERFORD RD CARLSBAD CA L Fees $ Add Fees ($J Total ($) Balance($) 290 H 0 290 0 about:blank 1/1 CALLAWAY GOLF WAREHOUSE T.I. 2180 RUTHERFORD RD. CARLSBAD, CA 92008 Fire Alarm Submittal 10-16-2015 fw Submitted By; N4VA SECURITY 10744 COTTONWOOD AV SUITE 103 Santee, CA. 92071 619-448-3007 Cont. Lic. C-10 # 802053 APPR AS SUBMITTED p - 1iU:L1u1iJJ1 ,:: CALLAWAY GOLF WAREHOUSE T.I. Fire Alarm Submittal Equipment List Qty Description Model Manufacture CSFM# 1 Fire Alarm Panel (EXIST.) 5820XL SILENT KNIGHT 7170-0559:135 1 Fire Alarm input module SD500-AIM SILENT KNIGHT 7300-0559:132 1 Connection to existing Duct Detector EX Horn/Strobe Cig Mnt multi-cd HSC WHEELOCK EX Strobe Cig Mnt multi-cd STC WHEELOCK --EX = EXISTING DEVICES TO BE RELOCATED Lot Wire 18/2Cond. (Initiation) Lot Wire 12/2 Cond. (Notification) Lot Wire I 8/4Cond. (Annunciator) Lot Wire 2 #14 THWN (Underground) 7125-0785:186 7125-0785:186 INTELLIKNIGHT ACCESSORY D SILENT KNIGHT by Honeywell SD500AIM & SD500-MIM Addressable Input Modules IntelIiKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM'and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The SD500-AIM and S0500-MIM are addressable input modules for use with the lntelliknight fire alarm control panels (FACP5). The SD500-AIM addressable input module mounts to a 4-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor SD500-AIM supports Class A (Style D) or Class B (Style B) contact monitor wiring SD500-MIM support for Class B (Style B) contact monitor wiring Attractive ivory cover plate with the SD500-AIM Small and lightweight size allows for flexible mounting options with the SD500-MIM DIP switch programmable for fast installation Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 502 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9" W x 4.9" H x 1" 0 (12.4Wx 12.4 H x 2.5 D cm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5" W x 2.5" H x 0.7" 0 (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing SDSOO.AIM SD500-MIM Approvals NFPA7I & NFPA72 UL 864 CSFM 7300-0559: 132 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL L HkJ [a c)a- cjo SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight D5jM pr SD500-MIM The modules shall be UL listed and compatible with Silent Knight's lntelliKnight CPs. FA The SD500-MlM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The 5D500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate 4I Tontact being monitored ZBAB @~ UL Wed £01 <111 AM Wring is Supervised Power United To contact I being monitored U ed7628 - 1 £01. -- - Compatible FACPs 5820XL 5820XL-EVS 5808 5700 Ordering InformationInformation S0500-AIM Input Module Addressable input module with ivory cover plate. S0500-MIM Input Module Addressable mini input module. 131k SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev. F subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446-6444. www.siientknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7300-0559:0132 Page 1 of 1 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com Model SD500-ARM Relay Module andE 0Aii', SDSOO-MlM Addressable Input Modules*. Models SD500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SDSOO-AIM and -MIM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Save up to 48% in current draw* - Up to 9 models now in I appliance - Save up to 14% cost of installation** Sleek Modern Aesthetics Finger Slide Switches Voltage Test PointS Multiple Voltages Audible Settings J 3 90, 95, 99 dfl J 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 J Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types it. az; ,Lrrt4J to /"/,s COOPER Notification Finally, Design and Safety Meet... Description: - The Wheeloce ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheeloce ExcederTm Senes incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can beset without the use of a tool and are located behind the appliance to prevent tampring. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pie-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. U Environmentally Friendly Low current Draw Compatibility and Requirements - Synchronize using the Wheelock®.Sync Modules or panels with built-in Wheelock® Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range * Compared to competitive models Patented ** Compared to previous models Horn Ratings per UL 464 - - - Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 1 8.0-17.5 10.04710.026 0.017 HNC 1 8.0-17.5 0.047 0.026 0.017 rur i, T ILl NOTE All CAUTIONS aid WARNINGS are identified by the symbol All wamlnqs are printed in bold capdal letters A WARNING: PLEAE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION IN CAREFULLY BEFORE USING, SPECIFYING . OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY-WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, - INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. - GeneràlNotés[;: •- General Notes: Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range". ....-. All candela ratings represent minimum effective strobe intensity based on UL Standard 1971 Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor, use with a temperature range of 32 *F to 120 *F (O *C to 49'C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). -: - Strobe Ratings Ratings per UL Standard 1971 : UL Max 24 VDC / 24 FWR 12 VDC Model Regulated Voltage IT 15/75 ( 60 110 115 135 150 177 185 15 15/75 Range VDC - ;8.033.O , 0057: 0.070 0.085 0,135 0:163 Q.182 0205: 0.253 0110 0.140 ST 8.0-33.0 5 0.103 0.182 • 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 & UL 464 at 24 VDC -s- UL Max Current* at 99 dBA _____ 24 VDC -• 12 VDC Model Regulated Voltage U 15/75 . 60--_0• :110 115 135 150 177 185 15 15/75 Range VDC HS . 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 - - 0.282 0.125 0.159 8.0-33.0 82 s 2 0.141 ORc 0.197 0.242 0.282 0.125 UL Max Current* at 95 dBA 24 VDC .12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 :. 0.272 0.122 0.153 HSC 80-33 0 0073 0087 0128 0139 0163 0186 0.230 0272 0.122 .• . •.Max 24VDC 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 :. 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 - - -. * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24' V66 units) For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units) For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For nfiltèd-atirigs see installatioh.intruction Specification & Ordering Information Strobe Sync w/SM, Mounting Model Candela DSM or 12/24 VDC* Options PS-6 & PS-8 H 1511575130175195111011351185 X X UMB HSW 15/1575/30175/95/11O/135/185 X X UMB S SRC 15/30/60175/95/1151150/177 X UMB S HSWC 15/30/60175/95/1151150/177 X X UMB • SIR 15/15751301751951110/1351185 X X UMB STW • 151157513017519511101135/185 X X UMB STRC 1513016017519511151150/177 X X UMB STWC 15130160/75195/1151150/177 X X UMB X X UMB ,J 7HN E91 I X X UMB' J X X UMB X X UMB *12 VDC models feature 15 & 15/75 settings UMB = Universal Mounting Base NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Nil WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder 'Spec Sheet 10110 Cooper Notification is Wheelock' (MCJ SAFEPATH WAV~TS Notification Architects and Engineers Specifications The notification appliances shall be Wheelock® ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling) All Series shall meet the requirements of FCC Part 15 Class .B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by afire Alarm Control Panel (FACP) with the ability to Operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall inc&porate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, .185 candela for wall mount and .15, 30, 60, 75, 95j, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. . The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series H.SAudible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow a mounting to single-gang double-gang 4-inch square 3.5-inch octal 4 inch octal or 1 00m European type back boxes Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. TheSeries HS and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required the appliance shall be compatible with Wheelock® S SM DSM Sync Modules Wheelock® Power Supplies or other manufacturers panels with built-in Wheelock® Patented Sync Protocol The strobes shall not drift out of synchronization àtany tune duringoperation. If the sync protocol fails to oprate, the strobe shall revert to a non-synchonized fläh-ráte and still' maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464,'California State Fire Marshal (CSFM), ULC, FM CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 712s-o7850168 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: LCqopqr Wheelock ' Inc. 7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conovercooperindustries.com DESIGN xcederSenModelsfsibe HShorn strobeand HN horn Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W(white). Additionally, a 'C' may be ded for ceWng mod&s and/or a '-NR' maybe added for non-resettable models. For non ,ad -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDCIFWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I - ,-- Listing Expires June 30, 2016