Loading...
HomeMy WebLinkAbout3215 MAEZEL LN; ; AS140337; Permit5/30/25, 11:53 AM AS140337 Permit Data City of Carlsbad Sprinkler Permit Job Address: 3215 MAEZEL LN Permit Type: SPRINK Parcel No: 2050800400 Lot #: 0 Permit No: AS140337 Status: ISSUED Applied 12/31/2014 Approved: 1/20/2015 Reference No.: Issued: 1/20/2015 PC #: Inspector: Project Title: PARKER RESIDENCE & GUEST HOUSE INSTALL ANEW FIRE SPRINKLER SYSTEM PER NFPA 13D FOR A NEW SINGLE FAMILY DWELLING AND GUEST HOUSE Applicant: INNOVATIVE FIRE PROTECTION INC STE 101 8779 COTTONWOOD AV SANTEE CA (619) 593-8200 (619)593-9133 Owner: PARKER FAMILY TRUST 08-29-95 3215 MAEZEL LN CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 210 0 210 0 about:blank 1/1 INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE #101 SANTEEI CA 92071 HYDRAULIC CALCULATIONS FOR PARKER RESIDENCE IGUEST HOUSE 3215 MAEZEL LANE CARLSBAD, CA. 92008 "FILE NUMBER: C5533 DATE: DEC 23, 2014 -DESIGN DATA- These plans hate been ret icwed for apparent Compliancewith he ctnrrIll ippiteable codes and sc.idirils it 1) 'C C in lie u li risdtcofi he owner or contr n actor eir uriii,e ill], ret Ink It support ol all t -ptcailon lot hniIliii lit tb the espresa uiidiisiaitdtii that lllis revieta lit liii aiu oltetes the oat tier iii contricior or their P10le-io"al enCiileel or architect Pir stile espitlisjhililv liar fUll colitpLalice with said codes tutU siandirtla. tic Itiditin the hiiildiitg code or for any responaihiltv or lehejeitcies errol a. olitlastoits or rial,t eaenee 1 lice pins whether or not floled ill lila resinas' /(T<evieaver jai Rf-C(flslMEND ttt.PPIlfl\,Al 11 RFCO MNIFIND API'RO\\,, AS NOrPr OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@ 3): SPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: .05 gpm/sq. ft. 240 sq. ft. 256 sq. ft. 1 sprinklers 21.0 gpm 26.0 gpm 21.0 gpm @ 29.4 psi 1/2 inch INNOVATIVE FIRE PROTECTION, INC BEN LEDESMA CARLSBAD FIRE AUTHORITY C.16.711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. AS140337 I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE 1HD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ!D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 58.5 54.0 500.0 58.5 26.0 52.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 52.4 26.0 2 0.0 - - - - 45.7 - - - 2A 0.0 - - - - 41.7 - - - D 0.0 - - - 40.4 - - - C 0.0 - - - - 34.4 - - - U 0.0 - - - - 33.6 - - - 3A 0.0 - - - - 33.5 - - - 3B 1.5 HOSE STREAM 31.8 5.0 3 3.5 - - - - 29.4 - - - 4 6.5 - - - - 26.9 - - - 5 10.0 - - - - 24.5 - - - 6 19.0 - - - - 19.4 - - - 7 19.0 - - - - 18.9 - - - 7A 18.0 K= 4.90 18.4 21.0 8 19.0 - - - - 19.4 - - - 8.1 19.0 - - - - 19.5 - - - 8A 18.0 - - - - 19.9 - - - 9 19.0 - - - - 19.4 - - - 9A 18.0 - - - - 19.9 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE 1HD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 26.0 0.995 PL 30.00 PF 6.7 1 0.0 SRCE 52.4 (N/A) 10.7 150 FTG TG PE 0.0 2 0.0 0.0 45.7 0.0 0.181 TL 37.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 45.7 0.0 4.0 psi, 26.0 gpm 2A 0.0 0.0 41.7 0.0 Pipe: 3 26.0 0.995 PL 3.00 PF 1.3 2A 0.0 0.0 41.7 0.0 10.7 150 FTG 2E PE 0.0 D 0.0 0.0 40.4 0.0 0.181 TL 7.00 PV Pipe: 4 FIXED PRESSURE LOSS DEVICE D 0.0 0.0 40.4 0.0 6.0 psi, 26.0 gpm C 0.0 0.0 34.4 0.0 Pipe: 5 26.0 2.067 PL 150.00 PF 0.9 C 0.0 0.0 34.4 0.0 2.5 150 FTG 2E2L PE 0.0 U 0.0 0.0 33.6 0.0 0.005 TL 172.00 PV Pipe: 6 26.0 2.067 PL 6.00 PF 0.1 U 0.0 0.0 33.6 0.0 2.5 150 FTG E PE 0.0 3A 0.0 0.0 33.5 0.0 0.005 TL 13.00 PV Pipe: 7 26.0 1.265 PL 10.00 PF 1.1 3A 0.0 0.0 33.5 0.0 6.6 150 FTG ET PE -0.6 3B 1.5 H.S. 31.8 5.0 0.056 TL 19.00 PV Pipe: 8 21.0 1.055 PL 10.00 PF 1.5 3B 1.5 H.S. 31.8 5.0 7.7 150 FTG 2E PE -0.9 3 3.5 0.0 29.4 0.0 0.092 TL 16.00 PV Pipe: 9 21.0 1.049 PL 3.50 PF 1.2 3 3.5 0.0 29.4 0.0 7.8 120 FTG C PE -1.3 4 6.5 1 0.0 26.9 0.0 0.142 TL 8.50 PV Pipe: 10 21.0 1.101 PL 5.00 PF 0.9 4 6.5 0.0 26.9 0.0 7.1 150 FTG E PE -1.5 5 10.0 0.0 24.5 0.0 0.074 TL 12.00 PV Pipe: 11 11.3 1.101 PL 40.00 PF 1.3 5 10.0 0.0 24.5 0.0 3.8 150 FTG EBR PE -3.9 6 19.0 0.0 19.4 0.0 0.024 TL 53.00 PV Pipe: 12 13.5 1.101 PL 8.00 PF 0.5 6 19.0 0.0 19.4 0.0 4.6 150 FTG BR PE 0.0 7 19.0 0.0 18.9 0.0 0.033 TL 14.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE lHD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUN. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 21.0 1.101 PL 2.00 PF 1.0 7 19.0 0.0 18.9 0.0 7.1 150 FTG 2BR PE 0.4 7A 18.0 4.9 18.4 21.0 0.074 TL 13.00 PV Pipe: 14 -7.5 1.101 PL 20.00 PF 0.5 7 19.0 0.0 18.9 0.0 2.5 150 FTG 4E PE 0.0 8 19.0 0.0 19.4 0.0 0.011 TL 48.00 PV Pipe: 15 0.0 1.101 PL 1.00 PF 0.0 8 19.0 0.0 19.4 0.0 0.0 150 FTG BR PE 0.4 8A 18.0 0.0 19.9 0.0 0.000 TL 7.00 PV Pipe: 15A -7.5 1.101 PL 2.00 PF 0.0 8 19.0 0.0 19.4 0.0 2.5 150 FTG ---- PE 0.0 8.1 19.0 0.0 19.5 0.0 0.011 TL 2.00 PV Pipe: 16 2.2 1.101 PL 3.00 PF 0.0 8.1 19.0 0.0 19.5 0.0 0.7 150 FTG B PE 0.0 9 19.0 0.0 19.4 0.0 0.001 TL 8.00 PV Pipe: 17 0.0 1.101 PL 1.00 PF 0.0 9 19.0 0.0 19.4 0.0 0.0 150 FTG BR PE 0.4 9A 18.0 0.0 19.9 0.0 0.000 TL 7.00 PV Pipe: 18 2.2 1.101 PL 32.00 PF 0.1 9 19.0 0.0 19.4 0.0 0.7 150 FTG 4E6R PE 0.0 6 19.0 0.0 19.4 0.0 0.001 TL 66.00 PV Pipe: 19 -9.7 1.101 PL 38.00 PF 1.2 8.1 19.0 0.0 19.5 0.0 3.3 150 FTG 3EB2R PE 3.9 5 10.0 0.0 24.5 0.0 0.018 TL 66.00 PV NOTES (HASS): Calculations were performed by the HASS 8.4 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.079 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Available pressure at source node 1 under full flow conditions is 58.48 psi compared to the minimum required pressure of 20.00 psi. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE 1HD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE (5) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: A MATERIAL: $40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEil ChkVlv BfyVlv GatVlv AlmChk DPViv NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Eli Tee LngEll ChkVlv BfyVlv GatVlv NPTee 2.067 7.00 10.00 4.00 17.00 8.00 3.00 10.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E B R C S G 45 El BrT RunT Cplg SwCk Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Eli Tee 45-Eli TeeRun Coupig SwgChk GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Eli Tee 45-Eli TeeRun Couplg SwgChk GatVlv NPTee 1.265 3.00 6.00 1.00 2.00 0.50 7.00 0.00 6.00 PAGE: M MATERIAL: CT-M HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Eli Tee 45-Eli TeeRun Coupig SwgChk GatVlv NPTee 1.055 3.00 8.00 2.00 3.00 0.00 8.00 0.00 8.00 :ISWI 70.0 G A 60.01 U G E 2 50.0 P R E S 40.0 S U R E 30.0 WATER SUPPLY ANALYSIS Static: 58.50 psi Resid: 54.00 psi Flow: 500.0 gpm LEGEND i Available pressure 58.48 psi @ 26.0 gpm 2 Required pressure 52.42 psi @ 26.0 gpm Source Supply Curve System Demand Curve 20.0 1 10.0 mm -14.71 I I I I I I 200 300 400 500 600 700 800 900 1000 FLOW (GPM) (Note: Dashed Lines indicate extrapolated values from Test Results) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE 1HD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE WATER SUPPLY CURVE 60+ 55+ \\\\ I * <-54.0 psi @ 500 gpm X Flow Test Point 50+ 45+ P 40+ RI El SI 5 35+ UI RI El 30+ P I SI I 25+ 20+ 15+ 10+ LEGEND 1 11 I X = Required Water Supply I 52.42 psi @ 26.0 gpm 5+ I 0 = Available Water Supply I 58.48 psi @ 26.0 gpm I ft 0++-+---+----+-----+ ------+ --------+ --------+ ---------+ -----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE #101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR PARKER RESIDENCE GUEST HOUSE 3215 MAEZEL LANE CARLSBAD, CA. 92008 "FILE NUMBER: C5533 DATE: DEC 23, 2014 -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@ 3): SPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: .05 gpm/sq. ft. 240 sq. ft. 256 sq. ft. 2 sprinklers 26.0 gpm 31.1 gpm 26.0 gpm @ 18.8 psi 1/2 inch INNOVATIVE FIRE PROTECTION, INC BEN LEDESMA CARLSBAD FIRE AUTHORITY C. 16 . 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE 2HD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 58.5 54.0 500.0 58.5 31.1 46.4 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 46.4 31.1 2 0.0 - - - - 37.1 - - - 2A 0.0 - - - - 33.1 - - - D 0.0 - - - - 31.3 - - - C 0.0 - - - - 25.3 - - - U 0.0 - - - - 24.1 - - - 3A 0.0 - - - - 24.0 - - - 3B 1.5 HOSE STREAM 21.9 5.0 3 3.5 - - - - 18.8 - - - 4 6.5 - -. - - 15.7 - - - 5 10.0 - - - - 12.9 - - - 6 19.0 - - - - 7.4 - - - 7 19.0 - - - - 7.3 - - - 7A 18.0 - - - - 7.7 - - - 8 19.0 - - - - 6.9 - - - 8.1 19.0 - - - - 6.9 - - - 8A 18.0 K= 4.90 7.1 13.0 9 19.0 - - - - 6.8 - - - 9A 18.0 K= 4.90 7.0 13.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE 2HD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.1 0.995 PL 30.00 PF 9.3 1 0.0 SRCE 46.4 (N/A) 12.8 150 FTG TG PE 0.0 2 0.0 0.0 37.1 0.0 0.252 TL 37.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 37.1 0.0 4.0 psi, 31.0 gpm 2A 0.0 0.0 33.1 0.0 Pipe: 3 31.0 0.995 PL 3.00 PF 1.8 2A 0.0 0.0 33.1 0.0 12.8 150 FTG 2E PE 0.0 D 0.0 0.0 31.3 0.0 0.251 TL 7.00 PV Pipe: 4 FIXED PRESSURE LOSS DEVICE D 0.0 0.0 31.3 0.0 6.0 psi, 31.0 gpm C 0.0 0.0 25.3 0.0 Pipe: 5 31.0 2.067 PL 150.00 PF 1.2 C 0.0 0.0 25.3 0.0 3.0 150 FTG 2E2L PE 0.0 U 0.0 0.0 24.1 0.0 0.007 TL 172.00 PV Pipe: 6 31.0 2.067 PL 6.00 PF 0.1 U 0.0 0.0 24.1 0.0 3.0 150 FTG E PE 0.0 3A 0.0 0.0 24.0 0.0 0.007 TL 13.00 PV Pipe: 7 31.0 1.265 PL 10.00 PF 1.5 3A 0.0 0.0 24.0 0.0 7.9 150 FTG ET PE -0.6 3B 1.5 H.S. 21.9 5.0 0.078 TL 19.00 PV Pipe: 8 26.0 1.055 PL 10.00 PF 2.2 3B 1.5 H.S. 21.9 5.0 9.6 150 FTG 2E PE -0.9 3 3.5 0.0 18.8 0.0 0.137 TL 16.00 PV Pipe: 9 26.0 1.049 PL 3.50 PF 1.8 3 3.5 0.0 18.8 0.0 9.7 120 FTG C PE -1.3 4 6.5 0.0 15.7 0.0 0.212 TL 8.50 PV Pipe: 10 26.0 1.101 PL 5.00 PF 1.3 4 6.5 0.0 15.7 0.0 8.8 150 FTG E PE -1.5 5 10.0 0.0 12.9 0.0 0.111 TL 12.00 PV Pipe: 11 12.8 1.101 PL 40.00 PF 1.6 5 10.0 0.0 12.9 0.0 4.3 150 FTG EBR PE -3.9 6 19.0 0.0 7.4 0.0 0.030 TL 53.00 PV Pipe: 12 6.4 1.101 PL 8.00 PF 0.1 6 19.0 0.0 7.4 0.0 2.1 150 FTG BR PE 0.0 7 19.0 0.0 7.3 0.0 0.008 TL 14.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE 2HD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 0.0 1.101 PL 2.00 PF 0.0 7 19.0 0.0 7.3 0.0 0.0 150 FTG 2BR PE 0.4 7A 18.0 0.0 7.7 0.0 0.000 TL 13.00 PV Pipe: 14 6.4 1.101 PL 20.00 PF 0.4 7 19.0 0.0 7.3 0.0 2.1 150 FTG 4E PE 0.0 8 19.0 0.0 6.9 0.0 0.008 TL 48.00 PV Pipe: 15 13.0 1.101 PL 1.00 PF 0.2 8 19.0 0.0 6.9 0.0 4.4 150 FTG BR PE 0.4 8A 18.0 4.9 7.1 13.0 0.031 TL 7.00 PV Pipe: 15A -6.7 1.101 PL 2.00 PF 0.0 8 19.0 0.0 6.9 0.0 2.2 150 FTG ---- PE 0.0 8.1 19.0 0.0 6.9 0.0 0.009 TL 2.00 PV Pipe: 16 6.5 1.101 PL 3.00 PF 0.1 8.1 19.0 0.0 6.9 0.0 2.2 150 FTG B PE 0.0 9 19.0 0.0 6.8 0.0 0.009 TL 8.00 PV Pipe: 17 13.0 1.101 PL 1.00 PF 0.2 9 19.0 0.0 6.8 0.0 4.4 150 FTG BR PE 0.4 9A 18.0 4.9 7.0 13.0 0.031 TL 7.00 PV Pipe: 18 -6.5 1.101 PL 32.00 PF 0.6 9 19.0 0.0 6.8 0.0 2.2 150 FTG 4E6R PE 0.0 6 19.0 0.0 7.4 0.0 0.008 TL 66.00 PV Pipe: 19 -13.2 1.101 PL 38.00 PF 2.1 8.1 19.0 0.0 6.9 0.0 4.4 150 FTG 3EB2R PE 3.9 5 10.0 0.0 12.9 0.0 0.032 TL 66.00 PV NOTES (HASS) Calculations were performed by the HASS 8.4 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.083gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.8 ft/sec at pipe 1. Available pressure at source node 1 under full flow conditions is 58.46 psi compared to the minimum required pressure of 20.00 psi. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE 2HD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE (5) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T IL C B G N Ell Tee LngEil ChkViv BfyVlv GatVlv NPTee 2.067 7.00 10.00 4.00 17.00 8.00 3.00 10.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) L E B R C S G 45 El BrT RunT Cplg SwCk Gate 1.101 1.00 7.00 5.00 1.00 1.00 8.00 2.00 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Eli Tee 45-Ell TeeRun Couplg SwgChk GatVlv NPTee 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 PAGE: L MATERIAL: CT-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Ell Tee 45-Ell TeeRun Couplg SwgChk GatVlv NPTee 1.265 3.00 6.00 1.00 2.00 0.50 7.00 0.00 6.00 PAGE: N MATERIAL: CT-N HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Eli Tee 45-Ell TeeRun Couplg SwgChk GatVlv NPTee 1.055 3.00 8.00 2.00 3.00 0.00 8.00 0.00 8.00 [:ISWI 70.0 G A 60.01 U G E 50.0 P 2 R E S 40.0 S U R E 30.0 WATER SUPPLY ANALYSIS Static: 58.50 psi Resid: 54.00 psi Flow: 500.0 gpm LEGEND 1 Available pressure 58.47 psi 5 31.1 gpm 2 Required pressure 46.39 psi 8 31.1 gpm Source Supply Curve System Demand Curve 20.0 i 10.0 -14.71 I I I I I 200 300 400 500 600 700 800 900 1000 FLOW (GPM) (Note: Dashed Lines indicate extrapolated values from Test Results) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 12/23/2014 C:\HASS 84\C5533 PARKER RESIDENCE 2HD GUEST HOUSE.SDF JOB TITLE: C5533 PARKER RESIDENCE WATER SUPPLY CURVE 60+ 0\\\\ I \\\\ \\\\\ 55+ \\\\ I * <-54.0 psi @ 500 gpm I Flow Test Point 50+ x 45+ P 40+ RI El SI 5 35+ UI RI El 30+ 20+ 15+ 10+ LEGEND I X = Required Water Supply I 46.39 psi @ 31.1 gpm 5+ I 0 = Available Water Supply 58.47 psi @ 31.1 gpm 0++-+---+----+-----+ ------+ --------+ --------+ ---------+ -----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) SPECI FI CATION SUBMITTAL SHEET FEATURES Sizes: U3/4" U 1" U 1-1/4' U 1-1/2' U 2' Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI - End connections Threaded ANSI B1.20.1 OPTIONS - (Suffixes can be combined) APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE (AU sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 (vertical 3/4", 1 1/4", 1 1/2' & 2") IAPMO® Listed (vertical 1 1/4"-2") CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (vertical 3/4") City of Los Angeles Approved (vertical 1-1/4-2") e NYC MEA 426-89-M VOL 3 U - with full port QT ball valves (standard) MATERIALS UL U U - less ball valves - with union ball valves Main valve body Cast Bronze ASTM B 584 U S - with bronze "y" type strainer Access covers Cast Bronze ASTM B 584 U TCU - with test cocks "vertical" up Internals Stainless Steel, 300 Series U V - with union swivel elbows (3/4" & 1") Elastomers Silicone (FDA approved) U OSY - with OS & Yate valves Buna Nitrile (FDA approved) U FDC - with fire hydrant connection.(2" only) Polymers Noryl, NSF Listed U FT - with integral male 45° flare SAE testfltting Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) 14 U QT-SET Quick Test Fitting Set U Test Cock Lock (Model TCL24) B_________ A G DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSIONS (a )proximate) WEIGHT MODEL AUNION B LESS BALL LESS WITH SIZE A BALL VALVES C D E F G BALL BALL VALVES VALVES VALVES mm in. mm in. mm in. I mm in. I mm in. mm in. I mm in. I mm in. mm lbs kq Ib 3/4 20 111/4 286 7 178 1 1/2 38 3 76 31/2 89 3 76 15 381 5 2.3 7 3.2 1 25 121/4 311 137/8 7 178 1 1/2 38 3 76 31/2 89 3 76 173/4 451 8 3.6 12 5.4 11/4 32 151/2419 121/2E 486 181/2 109/16 268 2 51 31/2 89 41/2 114 41/2 114 211/2 546.16 7.3 22 10 11/2 40 171/8435 19 1/8 109/16 268 2 51 31/2 89 41/2 114 41/2 114 22 3/4 578 16 7.3 22 10 2 50 181/4 460 20 109/16 268 2 51 31/2 89 41/2 114 41/2 114 25 1/8 638 16 7.3 28 1 12.7 'DOCUMENT#: REVISION: -- 4, 950XL • Page 1 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11_2 Phone: 905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zurn.com AS140337 FLOW CHARACTERISTICS MODEL 950XL 3/4", 1", 1 1/4", 1 1/2" & 2" (STANDARD & METRIC) FLOW RATES (us) 0 U) a- U) Cr) 0 - Ui U) U, Ui __________ ____ ___________ •1 - I I II I II FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8' 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 1 7 9 14 3/4' 8 12 17 25 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 1 63 95 52 1 78 1 105 167 DIRECTION OF FLOW OUTDOOR INSTALLATION INDOOR INSTALLATION SPECIFICATIONS The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be acces- sible for maintenance without removing the device from the line. The Double Check Valve Backflow Preventer shall be a WILKINS Model 950XL. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA; ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222.5356) Website: http://www.zurn.com Page 2 of 2 7 ot d SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler. Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including- Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Mode! RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities ha ving furls diction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may Impair the Integrity of these devices. It Is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and In turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U036786 Date . May/31/2013 Page :2 of 8 OPERATION 2—he" (52mm) Marking NPT1 /2 /1- Manufacturer Country Origin UL Mork Markin g 1— Lot Na. Year of Manufacture E —Temperature Rating —NSF Mark 1D Body (Copper Allay) Deflector (Phosphorus Bronze) O Casket (PTFE) ® Fusible Metal (Solder) tl Heat Collector (Copper) ® Cover Plate Assembly - ( 68mm) or 3—j14" (83mm) or 2— Ye"square (068mm) FIGURE 1. Model RC-RES K=4.9 Color Code Mrkin Control No. 6P37 RCS SPKR factor: K4.9 SIN SS8461 lo COVER PLATE SPRINKLER (Top view) (Bottom view) FIGURE 1-1. Marking (Color Code) TECHNICAL DATA Approvals: 0UL0 Listed, NSF-61 -G Sprinkler Identification Number (SIN): SS8461 Maximum Working Pressure: 175p5i (12.1 bar) Discharge Coefficient (Nominal K-Factor): K=4.9 GPM/psi112 (70.6 LPM/bar112) Temperature Rating: 1621 (72°C) Sprinkler with 1401 (60°C) Cover Plate 1751 (79°C) Sprinkler with 1621 (72°C) Cover Plate Color Code (Sprinkler) 1621 (72°C): Uncolored 1751 (799C): White Color Code (Cover Plate) 1401 (609C): No Mark 1621 (72°C): White-Color Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: White Painted, Ivory Painted, Nickel Plated or Any Color (Choose a color of acceptable colors) Physical Characteristics: Ref. Figure 1 In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) Normal Condition Cover Plate Operation mmll, Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) Document No. U036786 Date May/31/2013 Page 3 of 8 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by Individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, if Is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. The spray from the sprinkler Is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured In place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASIM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge O.IGPM/sq.ft. [4.07(Umin)I sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. Document No. U036786 Date May/31/2013 Page 4 of 8 TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8461 Maximum Ordinary Intermediate Coverage Maximum Temperature Rating Temperature Rating Deflector Minimum Area Spacing 162T (72°C) 175'F (791c) to Installation Spacing Flow I Pressure I Flow Pressure(D) Ceiling Ft. x Ft. Ft. Type Ft. (m xm) (m) GPM I PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) Smooth 12x12 12 13 7.0 13 7.0 Ceilings (3.7x3.7) (3.7) (49.2) (0.48) (49.2) (0.48) 318 to 7/8 Inches. 14x14 14 13 7.0 14 8.2 Beamed (4.3x4.3) (4.3) (49.2) (0.48) (53.0) (0.57) Ceilings per NFPA 16x16 16 13 7.0 14 8.2 13D,13R Concealed 9 (4.9x4.9) (4.9) (49.2) (0.48) (53.0) (0.57) or 13 (2.7) Installed in beam - 18x18 18 18 13.5 3/8 to (5.5x5.5) (5.5) (68.1) (0.93) - - 7/8 inches 20x20 20 21 I 18.4 below (6.1x6.1) (6.1) (79.5) (1.27) - - bottom of beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 9 feet (2.7m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation Is completed. The Protective Cap must be removed to place the sprinkler in service. Document No.U036786 Date May/31/2013 Page 5 of 8 Use a torque of 7 to 14 ft.lbs (9.5 to 19.ONm) to achieve a 1/2 inch NPT sprinkler joint. A maximum of 21 ft.Ibs. (28.5 Nm) of torque is to be used to install sprinklers. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Installinc, Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Make a Space Here Do NOT (6.4mm) over—Tighten e Sprinkler Mm. .)f (3.2mm) rrxi J E JI El Tolerance Limit El of Ceiling Level _______ Ave.Y Capcq Cailing LGroove Mounting Surfocej .v.. Surface e Socket unting Wrench2-3r(460mm) Ceiling Hole Diameter I CORRECTJ INCORRECTj ___________ FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No. U036786 Date . May/31/2013 Page 6 of L er Head ivecaS Step W j Cap Remover RC Step 2Lj Hook by turning fj Step 3 4 Pull down FIGURE 5. PROTECTIVE CAP REMOVAL Document No. U036786 Date May/31/2013 Page 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F/4 "C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler In case of fire. Install the cover plate assembly properly, as shown In Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. - - Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, Insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds lOOT /38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria'). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No. U036786 Date : May/31/2013 Page 8 of 8 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-RES (SIN: SS8461, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162'F (72°C) or 175'F (79°C)) Cover Plate Assembly: 2-5/8 inch (q5 68mm) or 3-1/4 inch (0 83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Finish Painted I Any Color Model I Ivory Painted Nickel Plated Painted 1 140°F (60°C) Cover Plate for RC-RES 162°F or 0 0 0 0J 162°F (72°C) Cover Plate for RC-RES 175°F *1: Choose one color of our acceptable color list. Regarding the color list information, please contact a local distributor. Tools for Installation of Model: RC-RES Socket for Model RC-RES Wrench & Socket for Model RC-RES Cap Remover RC Document No.U036786 Date May/31/2013 Fl Res 30, 49, 58 & 76 COP Pendent Bulletin 135 Rev. M ® Model Fl Rellgible Residential Sprinklers for Design Density of .05 gpm4t2 Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpinhlt2 (5 c) 01 (t SR Types: Fl Res 30 Pendent Fl Res 30 Recessed PendentJ172 Fl Res 30 Recessed PendentJFP Fl Res 49 Pendent Fl Res 49 Recessed PendentJFl Fl Res 49 Recessed PendentJFP Fl Res 58 Pendent Fl Res 58 Recessed Pendent/Fl Fl Res 58 Recessed Pendent/FP Fl Res 76Pëhdènt Fl Res 76 Recessed Pendent/Fl Fl Res 76 Recessed PendentJFP 13, Fl Res 30 COP Pendent Fl Res 49 COP Pendent Fl Res 58 COP Pendent Fl Res 76 COP Pendent 17, Fl Res 44HSW Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW 20, Fl Res 58 HSWX 21. KRes58 HSWX 22, Fl Res 58 HSW Recessed HSW/F2 23. Fl Res 44SWO Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer-to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VK KW Patents US Patent No. 6.516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers US Patent No. 7.353,882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model Fl Res 44 SWC Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res J Fl Res 44&58 Fl Res 44SWC Recessed HSW/F2 Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass-bulb Sprinkler Frame : Brass Casting Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: 1/2" NPT (R1/2) K-Factor: 3.0 (43.2) (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (83.5) (Actual) - Fl Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - Fl Res 76 Pendent Sprinkler 4.4(63) (Actual) - Fl Res 44 HSW Sprinkler Density: Minimum 0.05 gpmlft2 '4*J Fl Res 30, 49, 58 & 76 Fl Res 30, 49, 58 & 76 Recessed Pendent I Fl Recessed Pendent I FP Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model Fl Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R, or 132013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*. Fl or F2. Data: the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pen- dent sprinklers use only the Model 0 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, COP & SWO sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and 'Top" mark- ing must face ceiling. TYPe - Face of fitting to Ceiling Deflector Distance below bottom of beam Inch (mm) Inch (mm) Inch (mm) El 3/ (190) Mm. Recessed = 1/e (41.3) 3/8 (9.5) 1/4 (44.4) Max. Recessed = 1/8 (222) 1 1(25.4) F2 1/2.(12.7) Mm. Recessed = 1/8 (41.3) 3/,(9.5) 1I4 (44.4) Max. Recessed =1Vs 6) s(22.2j * Note: Escutcheons Fl or F2 may he used with Model Fl Res 49, 58 & 76 Recessed Pendent Sprinkler Model Fl Res 30 Recessed Pendent I F2 Model Fl Res 58 & 76 Pendent • Modi 4, s & tb iiecessea ten ent/F1 Fl escutcheon, 3/4" (19mm) adjustment l.35TGo3 2 1/4' HOLE 074. [57.2,,v,] - 7 75/15 OlA. itT — - . 1. X 1/2 REDUCER TURN COLLAR UNTIL T -- TIGHT AGAINST SPRINKLER FACE OF FITTING To WRENCH BOSS.t fl CEILING D1MENSIOFL I I/a" (F? ESCUTCHEON) J 3/8-7/a" (F2 ESCUTCHEON) ADJUST Fig. 1 Fig. 2 Technical Data: Fl Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Size Nominal Orifice iiiax. Pressure JSprinkler Inch ( psi (bar) Temp. Rating Max. Ambient Temp. Actual KSprinkler oC fctor Length1 Inch (mm) OF 0F //NPT 1/2) 2754" (8.2) 175 (12) 155 175 *CJ 68 79 2.25(57) 100 38 3.0 (43.2) 1 t Max. Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Spacing (155°F168°C) (175°F/79°C) Top of Deflector to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) (;PM(Limin' 1 PSI1ha !1 4LL'I) fJJPL 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0 (0,48) 8(30,3) 7.0 (0,48) Smooth ceilings 1¼ to 4(31.7 to 102) using E2 escutcheon. Beamed Ceilings per NFPA 13D, 13R 8(2,4) 0113 installed in beams 11Ato 13/4 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11(0,76) 10(37,8) 11(0,76) 16 X 16 (4,9 X 4,9) 16(4,9) 13(49) 18.8(1,3) 13(49) 18.8(1,3) (31.7 to 44.4) using E2 escutcheon For Ceiling types refer to NFPA 13, 13R OT 130 2. Technical Data: Fl Res 49 Pendent and Recessed Pendent (SIN R3516) Max. Sprinkler Max. Actual Sprinkler Thread Nominal Orifice Pressure Temp. Rating Ambient Temp. K Length S uze Inch C mm, psi (bar) OF °C Factor Inch (mm) OF °C W'NPT /6"(i1) 175(12)155 68 00 38 4.9(70.6) 2.25(57) (R 112) 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°Fit8°C) (175°F/790C) to Ceiling Spacing Ft x Ft (mx m) Ft (m) I Flow Pressure Flow Pressure Inch (mm) Ft (m) GPM (1/mm) PSI (bar) GPM (1/mm) PSI (bar) 12 x 12(3,6x3) 12 (3,E3) 13(49) 7.0(048) 13(49) 7.o(OAS) -1102) Smooth Ceilings 11/4 t04(31.7t0 using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 13 (49) 7.0(0,48) 13 (49) 7.0 (0,48) 11 to 4(25.4 to 102) using Fl 13(49) 7.0 (0,48) escutcheon. Beamed Ceilings per NFPA 8(2,4) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) 17(64,3) 1 12(0,83) 13D, 13R or 13 installed in beams 11/4 to 1/4 (31.7 to 18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12(0,83) --- 44.4) using F2 escutcheon, 1 20x 20(6,1 x 6,1) 20 (6,1) ' 20(75,7) 16.7 (1,14) 20(75,7) 16,7 (1,14) to 13/4 (25.4t044.4)using Fl For Ceiling types refer to NFPA 13, 13R or 13D Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°FI°L±.. __A1 75'F/79* to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) - - Inch (mm) Ft (m) PSIjb .PM.AL/min) GPM (1/mm) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 15 (57) 9.4 (0,65) 15 (57) 9.4 (0,65) Smooth Ceilings 4 to 8(100 to 203) using F2 escutcheon. 4t0 8(100 to 203) using Fl escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6 (0,73) 16 (60,5) 10.6(0,73) 16 x 16(4,9 x 4,9) 16(4,9) 17 (64,3) 12.0 (0,83) 17(64,3) 12.0 (0,83) 18 X 18(5,5 X 5,5) 18(5,5) 19(72) 15.0 (1,0) 19(72) 15.0 (1,0) 4¼t08(108 to 203) using F2 escutcheon, 4 to 8(100 to 203) 20 x 20 (6,1 x 6,1) 20(6,1) 22 (83,2) 20.2 (1,4) 22 (83,2) 20.2(1 0.2 (1,4) using Fl escutcheon Technical Data: Fl Res 58 Pendent and Recessed Pendent (SIN R3513) Thread Nominal Orifice Max. Sprinkler Max. Sprinkler Actual Size Inch (mm) Pressure Temp. Rating Ambient Temp. Length K Factor °F °C °F °C psi (bar) i. Inch (mm) 1/2"NPT 1/2" (13) 175 (12)175 155 68 100 79 150 38 66 5.8 (83.5) 2.25 (b f) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°Fi8°C) (l75F/79°C) to Ceiling Spacing flow Pressure Ft x Ft (mx m) Ft (m) Flow 1 Pressure Inch (mm) Ft (m) GPM (Lhiin) PSI (bar) GPM (lJmin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) 16(61) 7.6 (0,53) Smooth Ceilings 11/4 t0 4(31.7t0 102) using F2 escutcheon. 14 x 14(4,3 X 4,3) 14(4,3) 16(61) 7.6 (0,53) 16(61) 7.6 (0,53) 1 t 4(25.4t0 102) using El escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 16(61) i 7.6 (0,53) - 16(61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) 18 x 18 (5,5 X 5,5) 18 (5,5) 19 (72) 10.8 (0,75) 19 (72) 10.8 (0,75) iV4 to 1/4 (31.7 to 44.4) using F2 escutcheon, 1 t 13/4 (25.4 to 20 x 20(6.1 X 6,1) 20(6,1) 22(83,3) 14.4 (1,0) 22(83,3) 14.4(1.0) 44.4)using Fl escutcheon For Ceiling types refer to NFPA 13, 13Ff or 13D 3. TArrhniI flt Fl Res 76 Pendent and Recessed Pendent (SIN R7618) Max. Sprinkler Max. T K Sprinkler Thread i Nominal Orifice I Pressure . Temp. Rating . Ambient Temp. Factor Length Size Inch (mm) psi (bar) 'F 'C 'F 'C Inch (mm) 3/4'NPT "/32" (13.5) 175 (12) 155 68 7 175 9 100 150 38 7.6(109) 2.25 (57)66 Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Max. Spacing (l55°Fi8) (175°F/79°C) Top of Deflector to Ceiling Spacing Flow Pressure Flow GPM Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) (L/min) PSI (bar) 12x 12(3,6x3,6) 12(36) 21(795) 7.6(0,53) 21(79,5) 7.6(E53) Smooth Ceilings 4¼ to 8(108 to 203) using F2 escutcheon. 14 x 14(4.3 x 4,3) 14(4,3) 21(79,5) 1 7.6 (0,53) 21 (79,5) 7.6 (0,53) 4 to 8(100 to 203) using Fl escutcheon. 16x 16(4,9x4,9) 16(4,9) 21(79.5) 7,6(0,53) 21(79,5) 7.6(0,53) BeamedCeilingsperNFPA 13D, 13R or 13 installed in 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 21(79,5) 7.6 (0,53) 21(79,5) 7.6 (0,53) beams 41A to 8(108 to 203) us- --- - ....---..---.... ng F2 escutcheon, 4t08(100 20 x 20(6,1 X 61) 20(6,1) ---.---- .................... 23(87,1) 9.2 (0,63) 23(87,1) 9.2 (0,63) to 203) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 30, 49. 58 & 76 CCP Pendent* Model Fl Res 30, 49, 58 & 76 Recessed Pendent/ FP Not listed for corrosion resistance. 2 5/8" (66.7mm] 0/A. 2 5/16' 0/A. HOLE IN CEILING [58.7mm] - CUP 1"x1/2" REDUCER CUP CE/UN: 1/4" X. FACE IT FACE OF CEILING OIMENSION COVER AOJUSTMENT HT 1J5FGO4E Fl RES 30, 49, 58 & 76 COP FEND. Fig. 3 Note: The Fl Res 76 will use a 1" x Y4" reducer. FP push-on/thread-off escutcheon 2 5/8" 0/A. (66.7mm] —HOLE IN CEILING - 2 5/16" 0/A. - [58.7mm] CUP I -------I X 1/2 REDUCER LOW CEILING— 1 1/2" '[38. 1mm] MAX. lllltI1 FACE OF FITTING CE OF CEILING flflTo FA D/MENMENSION FP ADJUSTMENT Fl RES 49 PENDENT/EP Fig. 4 CCP Cover Plate Data: FP Escutcheon Data: "A" "B" Cover Adjustment CCP Height "C" Deflector Distance below bottom Inch (mm) inch (mm) of beam Inch (mm) 1/2(12.7) '/16 (24) 1/2 (13) - 1(25.4) /ie (7.9) /(19) ½ (13) - 1(25.4) "B" "A" Deflector Distance below bottom FP Position Inch (mm) of beam Inch (mm) Max. Recessed 1/16 (11) '/2(12.7) Mm. Recessed 16/6 (24) 1 (25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. 4. Technical Data: F1 Res 30 CCP Pendent and Recessed PendentlFP (SIN R3511) Nominal Max. CCP Assembly Max. K Sprinkler Thread Size Orifice Pressure Temp. Rating Ambient Temp. Factor Length Inch (mm) psi (bar) °F 0 °F 0 Inch (mm) ¼" NPT 21/6 -'(8.2) 175 (12) 135 57 100 38 3.0 (43.2) 2.25 (57) (R1/2) Ordinary Temp. Rating - Minimum Max. Coverage area Max. Spacing (155°F/88°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM(L/min) 1 PSI (bar) Smooth Ceilings 1/2 to 1(13 to 25.4) using CCP. 12 X 12 (3,6 X 3,6) 12(3,6) 8(30,3) 7.0(0,48) '/2t0 1 (13t025.4) using FP escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) - --- 14 x 14(4,3 x 4,3) 14(4,3) '11 (37,8) 13.4 (0,92) beams ½ to 1(13 to 25.4) using OCR ½ to 1(13 to 25.4) using FP escutcheon. For Ceiling types refer to NFPA 13, 13R or 130, Technical Data: Fl Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) T CCP Nominal Max. Thread Orifice Max. Assembly Ambient K Sprinkler Pressure Temp. Length Size Inch i. Temp. . Factor psi (bar) Rating 1 . Inch (mm): m, /16 (11) 175(12) 135 57 100 38 4.9 (70.6) 225(57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing 1550 80C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (mL GPM (1/mm) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0 (0,48) Smooth Ceilings ½ to 1(13 to 25.4) using 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0 (0,48) CCP. ½ to 1(13 to 25.4) using FP escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 14(53) 8.2 (0,56) Beamed Ceilings per NFPA 130, 138 or 13 8(2,4) installed in beams V2 to 1(13 to 25.4) using 18 x 18(5,5 x 5,5) 18(5,5) 18(68,1) 13.5 (0,93) CCP. ½ to 1(13 to 25.4) using FP escutcheon. 20x20(6,1x6,1) 20(6,1) 20(75,7) 16.7(1,14) For Ceiling types refer to NFPA 13, 138 or 130 Technical Data: Fl Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Nominal Max. CCP Assembly Max. i. Sprinkler Thread Orifice Pressure Temp. Rating Ambient Temp. Factor Length , °C Size °F Inch (mm) psi (bar) OF °C Inch (mm) 1/2"NPT (13) 175 (12) 135 57 100 38 5.8 (83.5) 2.25 (57) Max. Coverage Max. Spacing Ordinary Temp. Rating JF/6!J Top of Deflector to Ceiling Minimum area ' Ft x Ft (m x m) Ft (m) Inch (mm) Spacing Ft (m) Flow Pressure GPM (1/mm) PSI (b)_ 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) Smooth Ceilings ½ P. t0 1(13 to 25.4) using CC ½ to 1(13 to 25.4) using FP escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 130, 138 or 13 installed in beams ½ to 1 (13 to 25.4) using COP. 8(2,4) 18 x 18 (5.5 x 5,5) 18(5,5) 19 (72) 10.8 (0,75) 1/2 to 1(13 to 25.4) using FP escutcheon. 14.4(1,0) 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) For Ceiling types refer to NFPA 13, 13R or 13D 5. Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Nominal Max. CCP Assembly Max. K Sprinkler Thread Orifice Pressure Temp. Rating Ambient Temp, Factor Length OF °C Size Inch (mm) psi (bar) °F Inch (mm) /I'NPT '/32" (13.5) 175 (12) 135 57 J 7.6(109) 2.25 (57) Max. Coverage Max. Spacing Ordinary Temp. Rating (155- 0c) Top of Deflector to Ceiling Minimum Spacing Flow Pressure area Ft (m) Ft x Ft (m x m) Inch (mm) Ft (m) GPM (LJmp) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 21 (79,5) 7.6 (0,53) Smooth Ceilings ½ to 1(13 to 25.4) using OCR ½ to 1(13 to 25.4) using FR escutcheon. 14 x 14 (4,3 x 4,3) 14 (4.3) 21(79,5) 7.6 (0,53) 16 x 16 (4.9 x 4,9) 16(4,9) 21(79,5) 7.6 (0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams 1/2 101 (13 to 25.4) using COP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 22(83,3) 8.4 (0,58) ½ to 1(13 to 25.4) using FR escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 25(94,6) 10.8 (0,74) For Ceiling types refer to NFPA 13, 13R or 130 Model Fl Res 44 & 58 HSW FACE OF F/IT/NC TO - WALL DIMENSION -2 1/4" HOLE 0/A. f57,2mj - I" X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. 1J5F006-O 1 1/4" MIN. [3l.&,] 118 CEILING TO [3.2mm] I DEFLECTOR DIMENSION II 2 ,. 1/2 [13mm] ADJUSTMENT Model Fl Res 44 & 58 Recessed HSW/F2 Fl RES 58 & 44 HSW/F2 Fig. 5 Technical Data: F1 Res 44 HSW & HSW/F2 (SIN R3531) Thread Nominal Max. Sprinkler Ant K Sprinkler Orifice Size Pressure Temp. Rating Temp. Length Factor Inch (mm) psi (bar) Inch (mm) °F 0F ½'NPT 3//' (10) 175 (12) 55 68 79 100 38 150 66 4.4 (63) 2.45 (62)175 F2 escutcheon, 1/2" (13mm) adjustment Escutcheon. F2, Data: Face of Fitting Type Adjustment to wall Inch (mm) Inch (mm) F2 1/2 (13) /ie - 11/16 (4.7- 17.4) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) intermediate Temp. Rating (175°F179°C) Top of Deflector to Ceiling Inch (mm) GPM (11mm) PSI (bar) Minimum Spacing Ft (m) Flow Pressure GPM (Llmin) PSI (bar) Flow Pressure 12x12(3,6 x 3,6) 12(3,6) 12(45,4) 7.5 (0,52) 12 (45,4) 7.5 (0,52) 4 to 6(100 to 152); 1/2 (13) recessed using F2 escutcheon 8(2,4) 14x 14(4.3x4,3) 14(4,3) 14(53,0) 10.2(0,71) 14 (53,0) 10.2(0,71) 16 x 16 (4.9 x 4,9) 16(4,9) 16(60,6) 13.3 (0,92) 16(60,6) 13.3 (0,92) 16 x 18(4,9 x 5,5) 16(4,9) 18(68,1) 16.8 (0,53) 18(68,1) 16.8 (0,53) 18 x 18(5,5 x 5,5) 18(5,5) 19(72,0) 18.7 (1,29) 19(72,0) 18.7(1,29) 16 x 20(4,9 x 6,1) 16(4,9) 23 (87,1) 27.4(l.89) 23 (87,1) 27.4(l.89) 12 x 12(3,6 x 3,6) 12(3,6) 14(53,0) 10.2 (0,71) 14(53,0) 10.2 (0,71) 6t0 12 (152t0 305); ½ (13) recessed using F2 escutcheon 14 x 14(4,3 x 4,3) 14(4,3) 16(60,6) 13.3 (0,92) 16(60,6) 13.3 (0,92) 16 x 16(4.9 x 4,9) 16(4,9) 17(64,4) 15.0(1,04) 17(64,4) 15.0(1,04) 16 x 18(4,9 x 5,5) 16(4,9) 20(75,7) 20.7 (1,43) 20(75,7) 20.7(l.43) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4 (1,89) 23(87,1) 27.4 (1,89) For Ceiling types refer to NFPA 13, 1*3R or 13D Tech nical Data: F1 Res 58 HSW & HSW/F2 (SIN R3533) Escutcheon, F2, Data: Nominal Max. Sprinkler I Face of Fitting Max. Sprinkler Ambient K Length Ty Adjustment to wall Thread Orifice Pressure Temp. Rating Inch (mm) i Size Inch _________ Temp. Factor Inch _________ ________ Inch (mm) psi (bar) (mm) °F °C °F (mm) I I - I /8 - 1/18 155 68 100 ½" NPT 38 F2 1/2 (13) 1/9" (13) 175 (12) 5.6 (83.5) 2.45 (62) (4.7-17.4) (8½) 175 I 9 150 ' 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing J _155°FI68°C) (1F/79°C) Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) GPM (Lfmin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16 (60,6) 7.6 (0,53) 16(60,6) 7.6 (0,53) 4 to 6(100 to 152); 14 x 14 (4,3 x 4,3) 14(4,3) 18(68,2) 9.7 (0,69) 18(68,2) 9.7 (0,69) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 13.2 (0,91) 21(79,5) 13.2(0,91) ½ (13) recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 25(94,7) 18.6 (1,28) 25(94,7) 18.6(1,28) 8(2,4) 16 x 20(4,9 x 6,1) 16(4,9) 29 (109,8) 25.0 (1,73) 29 (109,8) 25.0 (1,73) 12 x 12(3,6 x 3,6) 12(3,6) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 6 to 12 (152 to 305); ½ (13) recessed 14 x 14(4,3 x 4,3) 14(4,3) 22(83,3) 14.4 (1,0) 22(83,3) 14.4(1.0) 16 x 16(4,9x 4,9) 16(4,9) 26(98,4) 20.1 (1,39) 26 (98,4) 20.1 (1,39) using F2 escutcheon 16x 18(4,9x5,5) 16(4,9) 31(117,4) 28.6(l, 97) 31(117,4) 28.6(1,97) For Ceiling types refer to NFPA 13, 13R or 13D I 1/4" (31.7Srom] I4ao,'oluor V'ooe Of Kill,,9 Ta Wail Dor,ens,00 I" 5 1/2" Redaaar' Raca1o094 Wail Hole t 2 5/I6 2 5/8" [58 74-] - [6b 68-1 0,0. TURN COLLAR UNTIL - TIGHT AGAINST SPRINKLER WRENCH ROSS. IV 12' [I0I.60oe,-,-, r0 .$04.80"o,',] PUSH ON COVER. THEN / TURN ID ADJUST UNTIL rOD , TIGHT AGAINST WALL. 3 51,16- 184 1 -1 C- 21/32' [420/oar] IrOODLO 1 //'H?7Q Ft RES 44 SWC Fig. 6 Model Fl Res 44 SWC Not listed for corrosion resistance. Tkn,.i flfR1 10c AA AU' (ItiI Nominal Max. Cover Max. Sprinkler Thread Orifice Pressure Temp. Ambient K Length Size Inch (mm) PSI (bar) Rating Temp. Factor Inch (mm) °F 0 °F 3/8" (10) 175 (12) 135 57 100 38 4.4(63) 2.45 (62) Ordinary Temp. Rating Top o Deflector to Minimum Max. Coverage area Max. Spacing t55°F/6) CeilinFt g p g x Ft (m x m) Ft (m) Flow Pressure Inch (mm) Ft (m) GPM (1/mm) PSI (bar) 12 x 12 (3,6 x 3.6) 12(3,6) 13(49,2) 8.7 (0,60) 10.2 (0,71) 14 x 14 (4,3 x 4.3) 14(4,3) 14 (53,0) _ - ....- - - ....- ........................4t06(l0o10 152); 16 x 16(4,9 x 4.9) 16(4,9) 17(64,3) 15.0 (1,1) --'-'-'----' ½ (13) recessed using F2 escutcheon ______ .......-.--.------.- -.-,-.------- 16 x 18(4,9 x 5,5) 16(4,9) 19 (71,8) 18.7 (1,13) 27.4 (1,89) 8(2,4) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 12 x 12(3,6 x 3,6) 12(3,6) 14(52,9) 10.2 (0,71) 11.7(081) 6 to 12 (152 to 305); ½ (13) recessed 14 x 14(4,3 x 4.3) 14(4,3) 15(56,7) 16 x 16(4,9 x 4,9) 16(4,9) 18(68,1) 16.8 (1,16) 20.7 (1,43) using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 20(75,6) For Ceiling types refer to NFPA 13, 13R or 13D Model KRes58 HSWX (Link) Technical Data: Fl Res 58 HSWX (SIN RA3533) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length Identification Inch (mm) psi (bar) ° 1 ° F Inch (mm) Number (SIN) . °C Bulb ½' NFl 1/2" (13) 175 (12) 155 68 100 150 38 5.8 (83.5) 66 2.45 (62) RA3533 (R½) 175 j 79 I Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175- 9;C) Top of Deflector to Ceiling Flow Pressure Inch (mm) GPM (Llmin) PSI (bar) I Minimum Spacing Ft (m) Flow Pressure GPM (L/min) PSI (bar) 18 x 20 (5,5 x 6, 1) 18(5,5) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 26.8(1,85) 4 to 6(100 to 152); 32.4 (2,23) ½ (13) recessed using F2 escutcheon 42.9 (2,96) 52.4 (3,75) 8(2,4) 20 x 20(6.1 x 6,1) 20(6,1) 30 (114) 26.8 (1,85) 30 (114) 16 x 22(4,9 x 7,3) 16(4,9) 33 (125) 32.4 (2,23) 33(125) 16 x 24(4,9 x 73) 16(4,9) 38(144) 42.9 (2,96) 38(144) 14 x 26 (4,3 x 7,9) 14(4,3) 42 (160) 1 52.4 (3,75) 42 (160) 18 x 20 (5,5 x 6,1) 18(5.5) 35 (133) 36.4 (2,5) 35(133) 36.4 (2,5) 42.9 (2;96) 6 to 12 (152 to 305); ½ (13) recessed 52.4(3,6) using F2 escutcheon 62.9 (4.34) 16 x 22(4,9 x 6,7) 16(4,9) 38 (144) 42.9 (2,96) 38(144) 16 x 24(4,9 x 7,3) 16(4,9) 42(160) 52,4 (3,6) 42(160) 14 x 26(4.3 x 7,9) 14(4,3) 46(174) 62.9 (4,34) 46(174) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 58 HSWX (Bulb) F~2 - I 11116- MIN. I [31.8mm] - j—t/a" CEILING TO [3.2mm] DEFLECTOR DIMENSION 27/32 DIA. [72.2mm] r~~4 - 1/2" [13mm] ADJUSTMENT FACE OF FITTING TO WALL DIMENSION 2 1/4" HOLE 0/A. f57.2mm] 1" X 1/2" REDUCER 1 15/16" DIA.,\jj)t [49,2mm 1 [ " -- T__________ TURN COLLAR UNTIL - TIGHT AGAINST SPRINKLER WRENCH BOSS. 135FG08 Fl RES 58 HSWX Fig.7 Technical Data: KRes58 HSWX (RA3593) Thread Nominal Max. Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Factor Length Identification Inch (mm) psi (bar) Inch (mm) Number (SIN) Link VY' NPT V2"(13) 175 (12) 100 38 5.8 (83.5) 2,45 (62) RA3593 Ordinary Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (165°F4°c) Ceiling Spacing Ft x Ft (m x m) Ft (m) Flow Pressure Inch (mm) Ft (m) GPM(tiniinj (bao 18 x 20(5,5 x 6,1) 18(5,5) 29 (109) 25(1,72) 26.8(1,85) 4 to 6(100 to 152), 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 16 x 22(4,9 x 7,3) 16(4,9) 33 (125) 32.4 (2,23) ½ (13) recessed using F2 escutcheon 16 x 24 (4,9 x 7,3) 16(4,9) 38 (144) 42.9 (2,96) 52.4 (3,75) 8(2,4) 14 x 26 (4,3 x 7.9) 14(4,3) 42(160) 18 x 20(5,5 x 6,1) 18(5,5) 1 35(133) 36.4 (2,5) 42.9 (2,96) 6 to 12 (152 to 305); ½ (13) Recessed 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 16 x 24 (4,9 x 7,3) 16(4,9) 1 42 (160) 52.4 (3,6) using F2 escutcheon 62.9 (4,34) 14 x 26(4,3 x 7,9) 14(4,3) i 46(174) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76 and Fl Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-F)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Wa- *DuPont Registered Trademark ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model Fl Res 30,49 & 58, SIN R351 1, R3516 & R3513 (Bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/Fl, Model Fl Res 30, 49 & 58 Recessed Pendent/ F2, Model Fl Res 30,49 & 58 Recessed Pendent/ FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector-to-ceiling distance listing shall be 1" to 8" maximum, only for Fl Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a ½' NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model F2)] [with 34" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model Fl Res 30, 49 & 58 Recessed Pendent!F1] [Mode! Fl Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30, 49 & 58 Recessed Pendent/FP] SIN R351 1, R3516 & R3513 (Bulletin 135). Model Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gprn/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. J. Concealed pendent sprinklers shall be Reliable Model Fl Res 30,49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon* coated Be!- "DuPont Registered Trademark 11. leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (740C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The Fl Res 58 HSW is also available with low lead frame. Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, Fl Res 58, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). Model Fl Res 76 Recessed Pendent/Fl, Model Fl Res 76 Recessed Pendent/F2, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1/2" adjust- ment (Model F2)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/ Fl] [Model Fl Res 76 Recessed Pendent/172] [Model Fl Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NFl thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½' cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 CCP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes Sprinkler F1 F2 FP EscutcheonsCover Plates Bronze Brass White Painted Chrome Plated Bright chrome Plated chrome White and Black White Painted Polyester(') coated Special Application Finishes Sprinkler Fl, F2, FP Escutcheons Electroless Nickel PTFE(Teflon)(n) Electroless Nickel PTFE (Teflon5) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull chrome Dull 0 Other finishes and colors are available on special order. Consult factory for details. (2) cULus listed Corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish *DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. IS) Recycled li bl ® (800) 431-1588 Sales Offices Paper Hea C (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address ES. Printed in U.S.A. 07/14 P/N 9999970235 Bulletin 014 Rev. K R - e I a e Quick Response I Standard Spray Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals 1.Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH 5 *NSF Certified to NSF/ANSi Standard 61 Annex G UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models Fl FR56, Fl FR56LL, Fl FR42, Fl FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models Fl FR56, Fl FR56LL, Fl FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR56, Fl FR56LL, Fl FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Series sprinklers C, - - 'U U ht Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/Fl/F2 I .,• . ;.. I Recessed Concealed Recessed Horizontal Sidewall Pendent PendentjFP XLH Upright XLH Pendent Pendent F1/F2 to apply water to a fire much faster than standard sprinklers of the same tem- perature rating. { The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass XLH Recessed bulb is specially constructed to provide Pendent FP fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. */p tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup O14FGO6A Model F1FR42, F1FRXLH Upright Technical data: Models Discharge Coefficient Response Thread Max. Working Mm. Working Temperature Finish Size Pressure Pressure Rating F1FR56 **F1 FR56LL1 K 5.6 Quick 1/2" NPT See See F1FR42 **F1FR42LL(l) K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" F1FRXLH Ratings" Table. F1FR28 K2.8 Low Lead Sprinklers available only with Temperature Rating 200°F/930c Material Data: Frame Deflector Load Screw *pmntle Cup Washer I Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 I CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or I or coated with PTFE Adhesive I Glass **Low Lead Brass or CDA Alloy 544 CDA Alloy 544 CDAAlloyslo CDA Alloy 693 Tape 2. Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread _________________________________________ I Nominal K Factor I Sprinkler I Approval Sprinkler Identification Number (SIN) Size I US Metric J Height Organization I Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm) " I 1/2" NPT (P1/2) I 5.6 80 2.25" (57mm) 1,2,3,4 I RA1414"2)(3))4( 7/16"(10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA1423"4 RA1413 4) 3/8(10mm) 1/2" NPT (R-1/2) 2.8 40 2.25" (57mm) 1 RA142114t RA1411 4> Conventional-Install in Upright or Pendent Position 15mm (1) 1/2" NPT (191/2) 5.6 1 80 1 57mm 1 3,4 1 RA14753 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval S rinkler Identification Number p (SIN) Size US J Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2(15mm))" F 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) [ 1,5 ( RA1415 7/16" (11 mm) 1 1/2" NPT (R1/2) { 4.2 60 2.25" (57mm) { 1,5 { RA1410 (1) cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark 3' Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent SprinkIer 1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor I Sprinkler Height Sprinkler Identification Number (SIN) US Metric (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA 1414 L 7/16" (10mm) 1/2 NPT (R-1/2) 4.2 60 2.25 57mm RA1413 L 3/8" (10mm) t 1/2" NPT (R1/2) f 2.8 1 40 2.25" (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2 (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1410 Refer to escutcheon data table for approvals & dimensions Model F1 FR56, F1FR56LL, F1FR42, 171FR42LL, F1FRXLH & F1FR28 Fl or F2 I X 112- REDUCER CUP COUIC 'ACE OF -10 W FACE OF CVL JA F ~IMUM RECEW 1- 112 T36-1 Ar MINIMUM RECM 7,25-M] AT MAXIMUM RECESS - 9/16714.3mm] Z12 12-1 .J AT MINIMUM RECESS = T254-] ADJUSTM ENT T 31/408. [82.6mm] Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler I j US Metric Orifice I Thread Size Height Organizations Identification Numbers (SIN) 1/2" (15mm) ½" NPT (R-1/2) 5.6 80 2.25" (57mm) 1, 2,3 RA148523 15mm I ½" NPT (R1/2) I 5.6 80 2.25" (57mm) 3(1) (I) LPC Approval is for pendent position only. (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. Electroless Nickel PTFE (Teflon®)" Plated - cULus listed corrosion Resistant Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4' (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Vertical Sidewall "DuPont Registered Trademark 4. Horizontal Sidewall I X 1/2 REDUCER J 1 75/16 D/A.\jJ(. (49.2mm] 11&2 27/32W 0/A. 7 (7) .4-12 [I0 I.6mm-304.8mm] CEILING TO DEFLECTOR Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Sprinkler _________________ Height and Type of Approval Nominal Orifice Thread Size Identification US I I Metric Light Hazard Ordinary Numbers (SIN) Hazard ½' (15mm) 1/2" NPT(R1/2) 1 5.6 80 2.63" (67mm) 1,2 1 RA1435(1))2)(3) 'cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 7725.4mm] AT MINIMUM RECESS 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4779mm] AT MINIMUM RECESS = 3/879.5mm] r2 114 -HOLE 074. I [5Z2mm] F? ESCUTCHEON AT MAXIMUM RECESS = 1-3/8734.9mm] 7 AT MINIMUM RECESS = 2-1/76752.4mm] V - F2 ESCUTCHEON AT MAXIMUM RECESS 7-5/8741.3mm1 AT MINIMUM RECESS = 2- 1/16752.4mm] [12mm] i--i TURN COLLAR UNTIL liGHT AGAINST SPRINKLER WRENCH BOSS I F? ESCUTCHEON J. 3/4779mm] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT RECESSED HSW W/F1 OR F2 ESCUTCHEON (7) FM APPROVED FOR 4 - 6 (101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with Fl, F2 or FP escutcheons for "Light Hazard" only. While FM limits use for the same hazard with the F2 escutcheon only. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) US Metric Sprinkler Cover 1/2" (15mm) 5.6 80 ½" NPT F1 FR 1350F1571C 1351F/571C 1001F/380C Orange 1 RA1414 ½" (15mm) 5.6 80 1/2" NPT F1 FR 1550F/68°C 1350F/57°C 100°F/38°C Red 1,4(1) RA1414 ½" (15mm) 5.6 80 ½" NPT F1 FR 1750F/791C 1650F/74°C 1000F/380C Yellow 1 RA1414 ½" (15mm) 5.6 80 1/2" NPT F1 FR 200°F/93°C 165°F/741C 150°F/65°C Green 1 RA1414 For VdS only = 155°F/68°C Norbulb and 1/2" [12,7mm] adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: I Nominal I Orifice "K" Factor Thread Size I L. Model I I Temp. Rating Max. Ambient I Bulb Color I i Approvals I Sprinkler I Identification US Metric I Sprinkler I I Cover Temp Number(SIN) 1/2" (15mm) 5.6 80 ½" NPT F1FR56LL 200°F/93°C 165°F/740C 150°F/65°C Green 1,5 RA1414 *DuPont Registered Trademark 5. Ix 1/2 REDUCING TEE OR ELBOW 1" x I/2" REDUCING TEE OR ELBOW 2 5/16" 0/A CUP -, CEILING-' - 1/2" MAX. COVER ADJUSTMENT COVER PLATE - ASSEMBLY 3 5/16" 0/A SPRINKLER -2 5/8" 0/A. HOLE IN CEILING I 1/2" MAX. FACE OF FITTING ...TO FACE OF CEILING DIMENSION 15/16" 2 5/16" 0/A - CUP ; :; CEILING-' 5/16' MAX, COVER ADJUSTMENT COVER PLATE - / ASSEMBLY 3 5/16" 0/A. SPRINKLER - 2 5/8" 0/A. HOLE IN CEILING 1 1/2' MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION ¶ 3/4" CONCEALED, 1/2" ADJUSTMENT Figure 1 Installation Aid A protective cap is included for use during installation, Important: The F1FR56 Sprinkler with Model COP cover plate is not an FM Approved combination, Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed, The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Sprinklers, use the Model O Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models Fl FR56/CCP & Fl FR56LLICCP Concealed Sprinkler use the 1/2" orifice, ½' NPT (R112), Model F1FR56 & Fl FR56LL Pendent Sprinkler with a threaded Model COP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (930C). The Model F1FR56LL Pendent is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model COP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the FlFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark 6. CONCEALED, 5/16" ADJUSTMENT Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2/8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RO1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model Fl FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color °C OF Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F(38°C) Red Intermediate 79' 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High (1) i 141 286 225°F (107°C) Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 - cULus permits use with Fl F2 or FP escutcheons for light hazard' only, while FM limits use for same hazard with F2 escutcheon only Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate1 Bronze Brass Chrome White Chrome Plated J_Chrome Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate11 Electroless Nickel PTFE(Teflon®)°(7) Electroless Nickel PTFE (Teflon®)* Bright Brass Bright Brass(') Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint1216 Black Paint Off White Off White(2)16 Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order, consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies onito RA1425, RA1414 and RA1475. cULus listed Corrosion Resistant Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. *DuPont Registered Trademark 7.