HomeMy WebLinkAbout2922 MANAGUA PL; ; AS080022; Permit5/30/25, 3:20 PM AS080022 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2922 MANAGUA PL Permit Type: SPRINK Parcel No: 2154941700 Lot #: 0 Reference No.: Permit No: AS080022 Status: ISSUED Applied 2/15/2008 Approved: 2/19/2008 Issued: 2/19/2008 PC #: Inspector: Project Title: ADMANI RESIDENCE 3 FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: Owner: PREMIER FIRE PROTECTION ADMANI FAMILY 2002 TRUST 04-09-02 P0 BOX 2027 439 JULIA DR LAKESIDE, CA BRAWLEY CA 619-871-9795 Fees ($) Add'I Fees ($) Total ($) Balance ($) 195 0 195 0 about:blank 1/1 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. LICENSE : 772285 DESIGNER ; STEVE PETRI DATE : 01-06-2008 FILE : ADMANI JOB NAME : ADMANI RES. TWO HEAD CALC 16 X 16 LOCATION : TWO HEAD CALC 16 X 16 DESIGN DATA. DESIGN CRITERION: MIN SPR FLOW AREA PER SPRINKLER TOTAL CALCULATED AREA TOTAL SPRINKLERS CALCULATED TWO HEAD CALC 16 X 16 13 Gpm 256 Sq Ft 512 Sq Ft 2 FLOW DATA. TOTAL SPRINKLER FLOW DOMESTIC DEMAND TOTAL WATER REQUIRED BASE OF RISER NODE: B FLOW: 26.2 Gpm 5.0 Gpm 31.2 Gpm 31.2 Gpm PRESSURE: 31.4 Psi AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE PHONE HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 1 ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. Date: 01-06-2008 File: C:\WINDOWS\ADMANI.RES JOB : ADMANI RES. TWO HEAD CALC 16 X 16 SOURCE I STATIC 100.0 Psi RESIDUAL : 99.0 Psi FLOW : 26 Gpm DESIGN I SPRINKLER MANUF : TYCO MODEL : LF11 4.9 I SPRINKLER Q : 13.0 Gpm VALVE : .0 Psi I SPRINKLER P : 7.0 Psi METER : 6.0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet ----------------------------------------------------------- FACTOR Psi Gpm 1 19.0 4.9 7.0 13.0 2 19.0 4.9 7.3 13.2 4 19.0 7.5 5 19.0 13.5 6 10.0 21.4 T 10.0 24.8 B .0 31.4 5.0 DOME A .0 33.8 M 16.0 31.7 S 16.0 SOURCE 40.1 31.2 SPRINKLERS FLOWING : 2 AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 512 Sq Ft MIN SPRINKLER FLOW : 13 Gpm REQUIRED DENSITY : .051 Gpm/Sq Ft COMPUTED DENSITY : .051 Gpm/Sq Ft TOTAL SPRINKLER FLOW 26.2 Gpm TOTAL DOMESTIC FLOW : 5 Gpm TOTAL WATER REQUIRED : 31.2 Gpm TOTAL SPRINKLER PRESS : 34.1 Psi WATER METER LOSS : 6.0 Psi VALVE FIXED LOSS : .0 Psi Copyright (2003) SUPPLY PRESS AVAILABLE : 98.6 Psi by DEMAND PRESS REQUIRED : 40.1 Psi Hydronics Engineering PRESSURE CUSHION : 58.4 Psi 34119 Fremont El, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY : 12.1 F/S (510) 487-9160 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : PREMIER FIRE PROTECTION. (619)-659--9795. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. Date: 01-06-2008 File: C:\WINDOWS\ADMANI.RES JOB : ADMANI RES. TWO HEAD CALC 16 X 16 PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 1 q= 13.0 K= 4.9 ------------------------------------------------------------------------------- L= 10.0 Pt 7.0 Pt 7.0 1 Q= 13.0 F=B F= 5.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.101 TL= 15.0 .0307 Pt .5 Pn 6.9 4 Pt 7.5 2 q= 13.2 K= 4.9 -------------------------------------------------------------------------- L= 1.0 Pt 7.3 Pt 7.3 2 Q= 13.2 F= B F= 5.0 C= 150 Pe .0 Pv -.1 Vel= 4.5 D= 1.101 TL= 6.0 .0318 Pf .2 Pn 7.2 4 Pt 7.5 4 q= .0 K= .0 -------------------------------------------------------------------------- L= 39.0 Pt 7.5 Pt 7.5 3 Q= 26.2 F= B9R F= 14.0 C= 150 Pe .0 Pv -.5 Vel= 8.8 D= 1.101 TL= 53.0 .1125 Pt 6.0 Pn 7.0 5 Pt 13.5 5 q= .0 K= .0 -------------------------------------------------------------------------- L= 17.0 Pt 13.5 Pt 13.5 4 Q= 26.2 F= LBBR F= 18.0 C= 150 Pe 3.9 Pv -.5 Vel= 8.8 D= 1.101 TL= 35.0 .1125 Pf 3.9 Pn 13.0 6 Pt 21.4 6 q= .0 K= .0 -------------------------------------------------------------------------- L= 16.0 Pt 21.4 Pt 21.4 5 Q= 26.2 F= LBRR F= 14.0 C= 150 Pe .0 Pv -.5 Vel= 8.8 D= 1.101 TL= 30.0 .1125 Pt 3.4 Pn 20.8 T Pt 24.8 T q= .0 K .0 -------------------------------------------------------------------------- L= 10.0 Pt 24.8 Pt 24.8 6 Q= 26.2 F= SCRR F= 10.0 C= 150 Pe 4.3 Pv -.5 Vel= 8.8 D= 1.101 TL= 20.0 .1125 Pf 2.3 Pn 24.2 B Pt 31.4 B q= 5.0 DOME -------------------------------------------------------------------------- L= 5.0 Pt 31.4 Pt 31.4 7 Q= 31.2 F= LLLB F= 26.0 C= 150 Pe .0 Pv -.4 Vel= 8.0 D= 1.265 TL= 31.0 .079 Pf 2.4 Pn 30.9 A Pt 33.8 A q= .0 K= .0 -------------------------------------------------------------------------- L= 150.0 Pt 33.8 Pt 33.8 8 Q= 31.2 F= 4L4ECCRF= 35.0 C= 150 Pe -6.9 Pv -.2 Vel= 5.0 D= 1.59 TL= 185.0 .0259 Pt 4.8 Pn 33.6 M Pt 31.7 N q= .0 K= .0 -------------------------------------------------------------------------- L= 10.0 Pt 31.7 Pt 31.7 9 Q= 31.2 F= G F= 1.0 C= 150 Pe .0 Pv -1.0 Vel= 12.1 D= 1.025 TL= 11.0 .2201 Pt 2.4 Pn 30.7 S Pt 34.1 -------------------------------------------------------------------------- Meter = 6.0 S Q= 31.2 <<< -------------------------------------------------------------------------- SOURCE >>> Pt 40.1 E=>45-E1b L=>90-E1b B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. DATE : 01-06-2008 FILE ; C:\WINDOWS\ADMANI.RES JOB : ADMANI RES. TWO HEAD CALC 16 X 16 PSI FIRE SPRINKLER HYDRAULIC GRAPH 100 , 90 80 ---- 70 6 5 U 40 30 - 20 - i n' 10 15 20 25 0 Supply Curve Static : 100.0 Resid : 99.0 Flow : 26.0 30 35 40 45 50 FLOW - Gpm Demand Curve Avl Pr : 98.6 @ 31 Req Pr : 40.1 @ 31 Pr Cush: 58.4 Copyright: Hydronics Engineering, 2003. 34119 Fremont Bl, Suite 609, Fremont, CA. 94555. (510) 487-9160. HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. LICENSE : 772285 DESIGNER : STEVE PETRI DATE : 01-06-2008 FILE : ADMANIS JOB NAME : ADMANI RES.'SIDEWALL.TWO HEAD CALC 16 X 16 LOCATION : 2922 MANGUA PLACE DESIGN DATA. DESIGN CRITERION: MIN SPR FLOW AREA PER SPRINKLER TOTAL CALCULATED AREA TOTAL SPRINKLERS CALCULATED SIDEWALL TWO HEAD CALC 14 X 14 14 Gpm 196 Sq Ft 392 Sq Ft 2 FLOW DATA. TOTAL SPRINKLER FLOW DOMESTIC DEMAND TOTAL WATER REQUIRED BASE OF RISER NODE: B 28.4 Gpm 5.0 Gpm 33.4 Gpm FLOW: 33.4 Gpm PRESSURE: 42.5 Psi AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE PHONE HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 1 ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. Date: 01-06-2008 File: C:\WINDOWS\ADMANIS.RES JOB : ADMANI RES. SIDEWALL TWO HEAD CALC 16 X 16 SOURCE I STATIC : 100.0 Psi RESIDUAL : 99.0 Psi FLOW : 28 Gpm DESIGN I SPRINKLER MANUF : RELIABLE MODEL : Fl RES 44 I SPRINKLER Q : 14.0 Gpm VALVE : .0 Psi I SPRINKLER P : 10.1 Psi METER : 6.0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm 1 19.0 ----------------------------------------------------------- 4.4 10.1 14.0 2 19.0 4.4 10.7 14.4 3 19.0 11.5 4 19.0 16.2 5 19.0 23.2 6 10.0 31.6 T 10.0 35.6 B .0 42.5 5.0 DOME A .0 45.3 M 16.0 43.8 S 16.0 SOURCE 52.6 33.4 SPRINKLERS FLOWING : 2 AREA PER SPRINKLER : 196 Sq Ft TOTAL DESIGN AREA : 392 Sq Ft MIN SPRINKLER FLOW : 14 Gpm REQUIRED DENSITY : .071 Gpm/Sq Ft COMPUTED DENSITY : .071 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 28.4 Gpm TOTAL DOMESTIC FLOW : 5 Gpm TOTAL WATER REQUIRED : 33.4 Gpm TOTAL SPRINKLER PRESS : 46.6 Psi WATER METER LOSS : 6.0 Psi VALVE FIXED LOSS : .0 Psi Copyright (2003) SUPPLY PRESS AVAILABLE : 98.6 Psi by DEMAND PRESS REQUIRED : 52.6 Psi Hydronics Engineering PRESSURE CUSHION : 46.0 Psi 34119 Fremont B1, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY : 13.0 F/S (510) 487-9160 HYDRONICS:'RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. Date: 01-06-2008 File: C:\WINDOWS\ADMANIS.RES JOB : ADMANI RES. SIDEWALL TWO HEAD CALC 16 X 16 PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 1 q= 14.0 K= 4.4 L= 17.0 Pt 10.1 Pt 10.1 1 Q= 14.0 F= RLLL F= 22.0 C= 150 Pe .0 Pv -.1 Vel= 4.7 D= 1.101 TL= 39.0 .0352 Pf 1.4 Pn 10.0 3 Pt 11.5 2 q= 14.4 K= 4.4 -------------------------------------------------------------------------- L= 3.0 Pt 10.7 Pt 10.7 2 Q= 14.4 F= LLB F= 19.0 C= 150 Pe .0 Pv -.2 Vel= 4.8 D= 1.101 TL= 22.0 .037 Pt .8 Pn 10.5 3 Pt 11.5 3 q= .0 K= .0 -------------------------------------------------------------------------- L= 24.0 Pt 11.5 Pt 11.5 3 Q= 28.4 F= BL F= 12.0 C= 150 Pe .0 Pv -.6 Vel= 9.6 D= 1.101TL= 36.0 .1301 Pt 4.7 Pn 10.9 4 Pt 16.2 4 q= .0 K= .0 -------------------------------------------------------------------------- L= 39.0 Pt 16.2 Pt 16.2 4 Q= 28.4 F= B9R F= 14.0 C= 150 Pe .0 Pv -.6 Vel= 9.6 D= 1.101 TL= 53.0 .1301 Pt 6.9 Pn 15.6 5 Pt 23.2 5 q= .0 K= .0 L= 17.0 Pt 23.2 Pt 23.2 5 Q= 28.4 F= LBBR F= 18.0 C= 150 Pe 3.9 Pv -.6 Vel= 9.6 D= 1.101 TL= 35.0 .1301 Pt 4.6 Pn 22.5 6 Pt 31.6 6 q= .0 K= .0 -------------------------------------------------------------------------- L= 16.0 Pt 31.6 Pt 31.6 6 Q= 28.4 F= LBRR F= 14.0 C= 150 Pe .0 Pv -.6 Vel= 9.6 D= 1.101 TL= 30.0 .1301 Pt 3.9 Pn 31.0 T Pt 35.6 T q= .0 K= .0 -------------------------------------------------------------------------- L= 10.0 Pt 35.6 Pt 35.6 6 Q= 28.4 F= SCRR F= 10.0 C= 150 Pe 4.3 Pv -.6 Vel= 9.6 D= 1.101 TL= 20.0 .1301 Pt 2.6 Pn 35.0 B Pt 42.5 B q= 5.0 DOME -------------------------------------------------------------------------- L= 5.0 Pt 42.5 Pt 42.5 7 Q= 33.4 F= LLLB F= 26.0 C= 150 Pe .0 Pv -.5 Vel= 8.5 D= 1.265 TL= 31.0 .0893 Pt 2.8 Pn 42.0 A Pt 45.3 A q= .0 K= .0 -------------------------------------------------------------------------- L= 150.0 Pt 45.3 Pt 45.3 8 Q= 33.4 F= 4L4ECCRF= 35.0 C= 150 Pe -6.9 Pv -.2 Vel= 5.4 D= 1.59 TL= 185.0 .0293 Pt 5.4 Pn 45.1 N Pt 43.8 HYDRONICS:'RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 3 ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. Date: 01-06-2008 File: C:\WINDOWS\ADMANIS.RES JOB : ADMANI RES. SIDEWALL TWO HEAD CALC 16 X 16 PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) M q= .0 ------------------------------------------------------------------------------- K= .0 L= 10.0 Pt 43.8 Pt 43.8 9 Q= 33.4 F= G F= 1.0 C= 150 Pe .0 Pv -1.1 Ve1= 13.0 D= 1.025 TL= 11.0 .2488 Pf 2.7 Pn 42.7 S Pt 46.6 -------------------------------------------------------------------------- Meter = 6.0 S Q= 33.4 <<< -------------------------------------------------------------------------- -------------------------------------------------------------------------- SOURCE >>> Pt 52.6 E=>45-Elb L=>90-Elb B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv H{DRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795. ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040. DATE : 01-06-2008 FILE : C:\WINDOWS\ADMANIS.RES JOB : ADMANI RES. SIDEWALL TWO HEAD CALC 16 X 16 PSI FIRE SPRINKLER HYDRAULIC GRAPH 100 1 1 I -n I I I I 1 9 8 7 60 50 - 40 30 20 10 1 10 15 20 25 ° Supply Curve Static : 100.0 Resid 99.0 Flow : 28.0 30 35 40 45 50 FLOW - Gpm -S Demand Curve Avi Pr 98.6 @ 33 Req Pr 52.6 @ 33 Pr Cush: 46.0 Copyright: Hydronics Engineering, 2003. 34119 Fremont Bi, Suite 609, Fremont, CA. 94555. (510) 487-9160. t qCO /Fire & Building I Products. Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 ,a rapid response HOME FIRE SPRINKLER SYSTEM Series LFII Residential Concealed Pendent Sprinklers, Flat Plate 4.9 K-factor General Description The Series LFII (1Y3596) Residential Concealed Pendent Sprinklers are decorative, fast response, fusible sol- der sprinklers designed for use In resi- dential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut to help assure a perfect fit installation. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 1313; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories In height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY3596) has a 4.9 (60,5) K-factor that provides the re- quired residential flow rates at reduced IMPORTANT Always refer to Technical Data : Sheet TFP700 for the INSTALLER WARNINGS that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 pressures, enabling smaller pipe sizes and water supply requirements. The Series LFII (1Y3596) has been designed with heat sensitivity and water distribution characteristics proven to help In the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII (1Y3596) Residential Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap Is temporarily removed for Installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling In- stallation Is complete the Protective Cap is removed and the Cover Plate Assembly Installed. WARNINGS The Series LFII (TY3596) Residential Concealed Pendent Sprinklers de- scribed herein must be Installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, In addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de-vices. The owner is responsible for maintain- ing their fire protection system and de- vices In proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. SprinkleriModel Identification Number SIN 1Y3596 JANUARY, 2006 Am Technical Data Approvals: UL and C-UL Listed. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.9 GPM/psi112 (70,6 LPM/bar112) Temperature Rating: 160°F/71°C Sprinkler with 135F/57'C Cover Plate Vertical Adjustment: 1/2 inch (12,7 mm) Finishes: Cover Plate: -. Flat White, Bright White, Chrome, or Custom Physical Characteristics: Body ..............Brass Cap ..............Bronze Saddle .............Brass Sealing Assembly .......... Beryllium Nickel wi Teflont Soldered Link Halves .....Nickel Lever . . . . ........ Bronze Compression Screw ......Brass Deflector ......Copper or Brass Guide Pin Housing .....Bronze TFP442 APPROvEp AS SUBMITTED These plaiis liase hei ssiih he ciIiT(Iii applwahl, c in ill jurimliction. The osrilci or cow cior in utiliie his review iii support ol all appIicitloll fol pci iii ssuh the CXPICSS uuderstaiicliiie Olaf this revicu ill ho svav iclicces tile owner or colitiic(or or their prtcssioiiil ehiginecu or architect for sole responsibility or lull compliance with said codes and standards. including the building code or tir any responsihiltv Im kticieiieies. errors. omissions or negligence in these Plans whether or 11)( toted in this review. Date 1/ 30105 Reviewer: RICOMMENT) APPROVAl. 11 RECOMMEND APPROVAL. AS NOTEI) Page 204 TFP442 Minimum Flow (b) and Maximum Maximum Residual Pressure Coverage Spacing For Horizontal Ceiling Area (e) Ft. (Max. 2 inch Rise Ft. x Ft. (m) for 12 inch Run) (mxm) 160"F171°C _____ Sprinkler 12x12 12 13 GPM (49,2 LPM) (3,7 x 3,7) (3.7) 7.0 psi (0,48 bar) 14x14 14 13 GPM (53,OLPM) (4,3 x 4,3) , (4,3) 7.0 psi (0,48 bar) - 16x16 16 13 GPM (60,6 LPM) (4,9 x 4,9)___ - (4,9) 7.0 psi (0.48 bar) 18x18 18 17 GPM (643LPM) (5,5 x 5,5) (5,5) 12.0 psi (0,83 bar) 20 x 20 20 20 GPM (75,7 LPM) (6,1x6,1) (6,1) 16.7 psi (1,l5bar) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 130 AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (1Y3596) RESIDENTIAL CONCEALED PENDENT SPRINKLER Guide Pins ......Stainless Steel Support Cup ..........Steel Cover Plate ..........Copper Retainer ............Brass Cover Plate Ejection Spring ..... .Stainless Steel tDuPont Registered Trademark Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, fails away to expose the Sprin- kler Assembly. At this point the Deflec- tor supported by the Arms drops down to its operated position. The fusible link of the Sprinkler Assembly is com- prised of two link halves that are sol- dered together with a thin layer of sol- der. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin- kler to activate and flow water. Design Criteria The Series LFll (1Y3596) Residential Concealed Pendent Sprinklers are UL and C-UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the Authority Having Jurisdic- tion. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers Is to be the greater of the following: The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and the maxi- mum allowable coverage area. A minimum discharge of 0.1 gpm/sq. ft. over the design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected oy the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be i i accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Ta- ble A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The Series LFII (TY3596) must be in- stalled in accordance with the follow- ing instructions: NOTES Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (i.e., do not apply pressure to the fusible link Assembly). A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- 3/17/2 5 09:53 7148792165 FIRE SPEC INC PAGE 03 , QUICK RESPONSE L OBE A UTOMA TIC SPRINKLERS FIRE SPRINKLER GL SERIES CORPORATION UPRIGHT.FENDENT VERTICAL SLOE WALL HORIZONTAL SIDEWALL DESCRIPTIONAND OPFwioN CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which uthlzes a 3mm frangibleglass ampule as the thermosensitive element. Ttis provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides in aesthetically pleasing appear- ance, it can be installed wherever standard spray sprinklers are specified when sUow.d by the applicable standards. it offers the additional feature of greedy Increased safety to life and Is available In various styles orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers QUICK RESPONSE should be used advisedly and under the direction of approving UPRIONT CONVENTIONAL authorities having junsdiction. The heart of Globe's GL. Series sprinkler proven actuating assembly is a hermetically sealed frangible glass smpuló that contains a precisely measured amount of fluid. When heat Is absorbed, the liquid within the bulb expands Increasing the internal pressure. At the prescribed temperature the Internal pressure within the ampule exceeds the swength of the glass causing the glass to shatter. This results in water discharge which Is distributed in an approved pattern depending upon the deflector style used. QUICK RESPONSE TECHNiCAL DATA PENDENT VERTICAL See reverse side for Approvals and Specifications. SIDEWALL Temperature Ratings - I 35°F (57*C). 155°F (68°C), 175°F (°C). 200°F (93°C). 286°F (141°C). Water Working Pressure Rating 175 psi (12 Bars). 'Factory tested hydrostatically to 500 psi (34 Bars). IGO 'Miximum low temperature glass bulb rating Is .67°F (.55°C). $ Frame - bronze • Deflector brass • Screw - brass a Bulb seat - copper • Spring - nickel alloy • Seal - teflon QUICK RESPONSE Bulb glass with alcohol based solution. 3mm size. HORIZONTAL SIDEWALL SPRINILER TEMFERATi1R RATING/CL4SSIFJCATJON and COLOR CODING CI AS COLOR BULB P4.F.P.A. MAXIMUM C!IUNQ TEMPERATURE - ORDINARY OMNG/RED jjjj INTERMEDIATE YELLOWIGREEN HIGH ELLIE 4077 AJRPARK DRIVE. £TAND$H, MICGAN 41U$ 959-1444583 • FAX 9*9446.9231 JUNE 2003 A-IC EUU.ETIN GL5lS, MY. 05 Model Fl Res 44 SWC 4•10 12' I2 11O1.50mo, To 1 1/4' [21. 75mo,] 304.80mmJ Fore 0/ FlUing To woo Di,oeosoo r PUSH ON COVER, THEN / TURN TO A.A/L/ST UNTIL / T?CHT AGAINST WALL. I' 0 1/2' Red— -, r 25/8 2 l- -\-----l-- 58r -f-- [4/ TURN COLLAR UNTIL SPRINKLER WRENCH Boss. I 2YIJ2* lJMO7 Adjosfr.onl Fl RES 44 SWC Fig. 5 Technical Data: Fl Res 44 SWC Thread Sprinkler Temp. Cover Temp. Rating Max. Pressure Max. Ambient Temp. K Sprinkler Length Size Rating psi (bar) Factor Inch (mm) OF IC °F °C °C 1/S"NPT 155 68 135 57 175 (12) 100 38 4.4 2.45 (62) Max. Sprinkler Spacing ft (m) Awy Ceiling Deflector Inch (mm) Flow gpm (Lpm) Pressure psi (bar) Sprinkler ldentflcation Number (SIN) 12 x 12 (3.6x3.6). 13(49.2) . 8.7(0.60) R3531 20.7(1.43) 14 x 14 (4.3x4.3) 14(53.0) 10.2(0.71) 4-6x(4.9x49) (101-152) 16- Th 17(64.3). 15.0.(1:1) 16x 18(4.9x5.5) 19 (71.8) 18.7(l.13) 16 x 20 (4.9x6.1) 23(87.1) 27.4(1.89) 12 x 12 (3.6x3.6) 6-12 (152-305) I 14(52.9) 10.2(0.71) 14 x 14(4.3x4.3) 15(56.7) 11.7 (0.81) 16 x 16(4.9x4.9) 18 (68.1) 16.8 (1.16) 16 x 18 (4.9x5.5) 20(75.6) 91