HomeMy WebLinkAbout136 MAPLE AVE; ; FA060066; Permit5/30/25, 3:18 PM FA060066 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA060066 Job Address: 136 MAPLE AV Status: ISSUED Permit Type: FALARM Applied 9/26/2006 Parcel No: 2042341701 Approved: 9/27/2006 Lot #: 0 Reference No.: Issued: 9/27/2006 PC #: Inspector: Project Title: VILLAS DE LUZ MONITORING SYSTEM PLAN CHECK & INSPECTION Applicant: Owner: JT SPECIALTY 10136 RANCHO ROBLE RD ESCONDIDO, CA 760-751-4083 Fees ($) Add'I Fees ($) Total(s) Balance ($) 117 0 117 .0 about:blank 1/1 JTSpecialty Systems, Inc. Villas de Luz 136 Maple Avenue Carlsbad, CA 92008 Fire Alarm System(Water Flow fonito ring) Submittal Ail APPROVED BMIT I pola t4 ii~ CARLSBAD FE 9EPARTMENT Reliability - Qualitj - Service. • • • • • . • • • • • • • • • • • • • • • • • • • JTSpecialty Systems, Inc. September 19, 2006 Carlsbad Fire Department 2560 Orion Way Carlsbad, CA 92010 Attention: Greg Ryan Reference: Fire Alarm System (Water Flow Monitoring) Fire Alarm System: Quantity Model No. I - 411UDAC Respectfully submitted, John Tomson iTSpecially Systems, Inc. Reliability - Quality - Service Description - Fire Alarm Communicator November 18, 1999 DF-51 852 8 Flre.uTeeAlarms www. firelite. corn GENERAL The Fire-Watch 411 UDAC from Fire-Lite is a compact, multifaceted, stand-alone or slave Fire Alarm Communica- tor designed for a variety of fire and non-fire applications. It provides four channels (inputs) that accept waterflow de- vices, two- and four-wire smoke detectors, pull stations, and other normally-open contact devices. The 411 UDAC is a cost-effective solution for applications that require an existing (or new) Fire Alarm Control or Security Panel to transmit system status to an off-site monitoring facility for Central or Remote Station compliance. Due to its extremely flexible programming options, the 411UDAC is also ideal for use as a stand-alone unit to monitor: sprinkler systems for waterflow and supervisory conditions; processes (i.e., water level, gas detection, loss Of air flow); and normally- open contact devices. With fifteen selectable transmis- sion formats, including Ademco Contact ID, compatibility with virtually all Digital Alarm Communicator Receivers (DACR) is ensured. Programming can be accomplished on-site with a hand-held programmer (PRO-411), or re- motely utilizing an optional PK-411UD Windows®-based remote upload/download software package. The PK-411 Ut) upload/download software also permits system interroga- tion and revision from a remote site. FEATURES Four supervised monitoring channels (inputs): three fixed Style B (Class B) and one Style A (Class A) or Style B (Class B). inputs may be individually programmed for stand- alone applications, or when monitoring a host con- trol panel, for: V Two- and four-wire smoke detectors (Inputs 1 and 3). V Pull station. v' Normally-Open contacts. V Host panel trouble (slave mode). v' Supervisory. V Supervisory (autoresettable). V Waterflow (silenceable). V Waterflow (non-silenceable). V Process monitoring. V Process monitoring (autoresettable). One Style Y (Class B) Notification Appliance (bell) Cir- cuit (NAC). 1.0 Amp notification appliance power. Coded (temporal) notification appliance (bell, signal) cir- cuit. 12 VDC operation. Capable of 60 hours of standby. 411UDAC Fire Alarm Communicator Section: Control/Communicators M A EA 328 94-E Vol. Vi S624 41IUDAC Seven Individual LEDs; six visible through door: V AC Power. V System Trouble. V System Alarm. V Supervisory. V Communication Fail. V Battery Trouble. V Earth Fault (not visible with door closed). Dual telephone lines: V Dual telephone line voltage detect. V Alternating phone lines for 24-hour test mes- sages (programmable). Industry-first, UL recognized, "dialer runaway" pre- vention feature. Windows® is a registered trademark of Microsoft Corporation. California State Fire Marshal 7300-0075:174 This document is not intended to be used for installation purposes. We try to keep our product informa- tion up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.IS09001 All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. I U Phone: (800) 627-3473 Toll Free FAX: (877) 699-4105 FAX Back:(888) 388-3299 & MANIMC1flIf DF-51852 - Page 1 of 4 New tong-distance Carrier Access Code (CAC) compli- ant, accepting 20-digit central station and service termi- nal telephone numbers. Industry-first, user-selectable restoral methods. Fully programmable transmittal codes for fire and non- fire (e.g., process monitoring) applications. Capable of transmitting the following DACTinforma- tion, In addition to vital system Status of the host control panel: V DACT troubles. V Telephone line 1 and 2 voltage fault V Primary or Secondary Central Station communica- tion fault. V System off-normal. V 24-hour normal test. V 24-hour abnormal test. Includes 15 popular communication formats, including the widely used Ademco Contact ID format, ensuring compatibility with virtually all DACRs. Local piezo sounder with separate and distinct sounds for various conditions. Acknowledge/System Silence and Reset switches. Alarm verification. Signal silence inhibit. Autosilence. Trouble reminder (with 24-hour resound). Real-time clock. OPTIONAL: two Form-C relays (411 RK), fully pro- grammable to activate for the following conditions: V Fire alarm. V Process monitoring (autoresettable). V Host control panel trouble. V Total communication trouble. V Fire supervisory (latching). V Fire supervisory (autoresettable). V DACT trouble (factory default for relay). V Process monitoring. Optional PK-411UD Remote Upload/Download Kit. Optional DP-2 Dress Panel (required for Canadian ap- plications). HOUSING The cabinet is red and measures 14.5" (36.83 cm) high x 12.5" (31.75 cm) wide and 2.875 (7.303 cm) deep. It pro- vides space for up to two 7 A.H. batteries (order batteries separately). An optional dress panel, DP-2 (required for Canadian installations), which mounts inside the cabinet, is available. The dress panel restricts access to the sys- tem wiring but allows access to the membrane switch panel. PHONE LINE CONNECTIONS Two modular phone connections are provided on the 411 UDAC, accessible by simply opening the door. They provide connections for two separate telephone lines us- ing standard RJ31 X or RJ38X jacks. Both telephone lines are constantly supervised for proper voltage and current. If one phone line goes into fault, and the remaining is op- erational, a report is sent to the central or remote station via the operable phone line. COMMUNICATION FORMATS 0: 4+1 Ademco Express Standard, DTMF, 1400/2300 ACK. 4+2 Ademco Express Standard, DTMF, 1400/2300 ACK. 3+1 Standard 1800 Hz Carrier, 2300 Hz ACK. 3+1 Expanded 1800 Hz Carrier, 2300 Hz ACK. 3+1 Standard 1900 Hz Carrier, 1400 Hz ACK. 3+1 Expanded 1900 Hz Carrier, 1400 Hz ACK. 4+1 Standard 1800 Hz Carrier, 2300 Hz ACK. 4+1 Expanded 1800 Hz Carrier, 2300 Hz ACK. 4+1 Standard 1900 Hz Carrier, 1400 Hz ACK. 4+1 Expanded 1900 Hz Carrier, 1400 Hz ACK. 4+2 Standard 1800 Hz Carrier, 2300 Hz ACK. 4+2 Expanded 1800 Hz Carrier, 2300 Hz ACK. 4+2 Standard 1900 Hz Carrier, 1400 Hz ACK. 4+2 Expanded 1900 Hz Carrier, 1400 Hz ACK. Contact ID, DTMF, 1400/2300 ACK. Future Use. SPECIFICATIONS This digital communicator/transmitter has been de- signed to comply with standards set forth by the fol- lowing regulatory agencies: Underwriters Laboratories, Inc. NFPA 72 National Fire Alarm Code. CAN/ULC: S527 - M87 Standard for Control Units for Fire Alarm Systems. FCC Registration: OAAUSA-25431-AL-E. Ringer Equivalence: 0.5 B. For Canadian Applications: IC Certificate Number: 2132 9028 A. Ringer Equivalence Number (REN): 0.2. PROGRAMMING: An optional digital programming unit with a keypad, model PRO-411, is available for program- ming the 411 UDAC. It is also used for troubleshooting and accessing the various modes of operation. Off-site pro- gramming can be accomplished with the optional PK-411UD kit (includes 3.5" disks and manual). The PK-411UD enables a user to program the 411 UDAC off- site via the public switched telephone network using any personal computer with Windows 3.1 or higher or Windows 95 and a 1200-baud Hayes® compatible modem. GENERAL SPECIFICATIONS: AC Power (17133): 120 VAC, 60 Hz, 0.3 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery (Lead-Acid Only) (43): Maximum charging cir- cuit: normal flat charge 13.7 V @ 0.6 amps. Maximum charger capacity: 14 A. H. battery. Channels/Inputs (TB2 Terminals 1 through 10): Programmable Channels 1 through 4. Power-limited circuitry. Fully supervised (monitored for opens, shorts, and earth faults). Normal operating voltage: 12.0 VDC (ripple 100 mV maximum). End-of-line resistor: 2.2K ohms, 1/2 watt (part it 27070, UL listed). Page 2of4 - OF-51852 Operation for each channel: Channel/Input 1, Style B (Class B) two-wire smoke de- tector input and Channel/Input 3, Style B (Class B) or Style 0 (Class A) two-wire smoke detector or waterflow input. Channel/Input 2 and Channel/Input 4 Style B (Class B) contact closure input. Refer to Device Compatibility Document for listed com- patible devices. Notification Appliance Circuit (TB4 Terminals 1[+] and 2(—]): Style V (Class B) circuit. Power-limited and supervised (monitored for opens, shorts, and earth fault). Operating voltage nominal 13.8 VDC. Current for all external devices: 1.0 amp. End-of-line resistor: 2.21K ohms, 1/2 watt (PIN 27070). Refer to Device Compatibility Document for listed com- patible devices. Two Optional Form-C Relays T81 Terminals 1 through 6): Operating voltage: nominal 12 VDC. Contact rating: 2.0 amps © 30 VDC (resistive), or 0.5 amps @ 30 VAC. 12 VDC Resettable Power (TB4 Terminals 3[.i.] and 41-1): Operating voltage: nominal 12 volts. Up to 200 mA available to power four-wire smoke detec- tors. Power-limited and supervised circuitry. Recommended maximum standby current: 50 mA. NOTE: 1) For power supply and battery calculations, refer to the 411UDAC manual. OPERATING POWER: Primary Power Source (AC): AC power connections are made inside the 411 UDAC cabi- net. The primary power source is 120 VAC, 60 Hz, 0.3 amps. Secondary Power Source (Batteries): One 12-volt bat- tery can provide power for up to 7 A.H. applications. Two 12-volt, 7 A.H. batteries (in parallel) can provide power for up to 14 A.H. applications (60 hour standby). The battery charger is current-limited and capable of recharging sealed lead-acid-type batteries. The charger shuts off when the system is in alarm. Refer to the battery calculations table in the 411 UDAC manual to determine the correct battery rating. TRANSFORMER ASSEMBLY: One transformer is shipped in the same carton as the cabinet and main circuit board but not mounted in the cabinet. The transformer should be installed before the cabinet is mounted to the wall. AUXILIARY RELAY: Two optional Form-C relays (411RK) are available for installation on the 411 UDAC main circuit board. The relays are programmable for activation on fire alarm, host panel trouble, fire supervisory, process monitoring, total communications failure, and DACT trouble. Relay contact rating: 2.0 amps © 30 VDC (resistive); or 0.5 amps © 30 VAC (resistive). PRODUCT LINE INFORMATION Model Description 4111JIDAC Four-channel, dual-line, stand-alone or slave Fire Alarm Communicator. Includes housing, operating and programming instructions. Use PRO-411 (below) hand-held DACT program- mer for local programming; or PK-411 UD (be- low) Windows-based programming software for remote programming and real-time diag- nostics. DP-2 Dead-front dress panel, required for Cana- dian applications. PRO-411 Optional hand-held DACT programmer which can be used to troubleshoot and program the 411UDAC, as well as access the various modes of operation. PK-411 UD Remote upload/download, Windows 95 com- patible, programming software kit (3.5" disk and PK-411UD Program Manual). The PK- 411UD enables a user to program the 411 UDAC off-site via the public switched tele- phone network using any personal computer with Windows 3.1 or greater or Windows 95 and a 1200-baud Hayes®-compatible mo- dem. 411RK Optional dry auxiliary Form-C relays, with contacts rated for 2.0 amps @ 30 VDC (re- sistive) or 0.5 amps @ 30 VAC (resistive). Optional use requires two relays. MCBL-7 DACT phone cord, seven feet long (two re- quired). M1 270 Battery, 12-volt, 7.0 AH (one required for 24- hour systems; two [wired in parallel) required for 60-hour systems). See page 4 for COMPATIBLE UL-LISTED RECEIVERS DF-51852 - Page 3of4 COMPATIBLE UL-LISTED RECEIVERS The chart below shows UL-listed receivers compatible with the 41IUDAC: Format # (Adresses 16 & 42) Ademco Silent Knight 9000 m CS4000 (3) FBI CP22OFB Osborne Hoffman 1 & 2 Radionics 6000/6500 (5) Sescoa 3000R SurGuard MLR-2 0 4+1 Ademco Express V V V 1 4+2 Ademco Express V V 4 (8) V V 2 3+1/Standardl1800/2300 V V (2) V V (4) V V(5,6) V V 3 3+1/Expanded/1800/2300 V V (2) V V 4) V V V 4 3+1/Standard/1900/1400 V V (2) V (4) V V V 5 3+1/Expandedl1900/1400 V V (2) V (4) V V V 6 4+1/Standard/1800/2300 V V (2) V V (4) V V (5) V 7 4+1/Expanded/1800/2300 V V (2) V (4) V V V 8 4+1/Standard/1900/1400 V V (2) V (4) V V V 9 4+1/Expanded/1900/1400 V V (2) V 4) V V V A 4+2/Standard/1800/2300 V V (2) V V (4) V V (5) V V B 4+2/Expanded/1800/2300 V V (2) V 4) V V V C 4+2/Standard/1900/1400 V V (2) V (4) V V V D 4+2/Expanded/1900/1400 V V (2) V (4) V V V E Ademco Contact ID V V V V 51735.IbI KEY: With 685-8 Line Card with Rev 4.4d software. With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software. Rev. 4.0 software. FBI CP220FB Rec-1 1 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software. Model 6500 with Rev 600 software. Model 6000 with Rev 204 software. With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software. Model 2 only. Version 1.62 software. Page 4ot4 - IDF-51852 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:174 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models UDACTF, 411,411 -UD and 411 UDAC digital alarm communicator transmitter and Model ABS-8RF enclosure (for use with Model UDACTF only). The UDACTF, 411, 411 UD and 411 UDAC units are intended to provide central station service over a standard two-wired telephone switching network. The UDACTF is for use with listee's separately listed fire alarm control units. The 411, 411 UDAC and 411-UD are for use with any UL and CSFM listed control units. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: UDACTF: 21.2- 28.2 VDc 411,411-UD: 11.7- 12.4 VDC (nominal) or 21.3-24.0 VDC (nominal) 411 UDAC: 120 VAC, I2VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as digital alarm communicator transmitters for use with listee's separately listed electrically compatible fire alarm control units. Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or k..'. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager