Loading...
HomeMy WebLinkAboutPRE 2026-0008; ROOSEVELT GRAND AND STATE MIXED USE; Admin Decision LetterMarch 25, 2026 Kirk Moeller 2888 Loker Avenue E Ste. 317 Carlsbad, CA 92010-6685 {city of Carlsbad SUBJECT: PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE APNS: 203-181-03, -04, -07, -12, 203-291-01 Thank you for submitting a preliminary review for a five-story, 69-unit mixed-use project spanning multiple properties in the Village & Barrio Master Plan with a combined area of 1.46 acres. The impacted addresses are 2802 State Street, 2801-2885 Roosevelt Street, 2933 Roosevelt Street, and 570-590 Grand Avenue. The concept "L-shaped" mixed use project, which includes the construction of two separate five- story mixed use buildings, fronts Roosevelt Street to the east, Grand Avenue to the south and the Tyler Street Alley and State Street to the west. The properties are currently developed with commercial uses and associated at-grade parking lots. All existing buildings will be demolished. Specifically, the following development is proposed : Building A • Street frontage on Roosevelt Street to the east, Grand Avenue to the south and Tyler Street Alley to the west • Two-level, 123-space parking garage with vehicular access from two points: Roosevelt Street and Tyler Street Alley. The parking garage off Tyler Street Alley is partially subterranean. A total of 123 spaces are proposed in Building A, 61 of which will be subterranean. • Four stories of residential with 9,620 square feet of ground floor commercial area • 39 units ranging in size from 1,589-4,043 square feet Building B • Street frontage on State Street to the west and Tyler Street Alley the east • One-level, at-grade, 31-space parking garage, including 13 parking lifts, with access from the Tyler Street Alley. • Four stories of residential above a 6,000-square-foot ground floor restaurant • 30 units ranging in size from 1,051-2097 square feet Additional Details: • Parking will be shared between the two buildings • Density is 47.2 dwelling units per acre (du/ac), resulting in a 35% density bonus • Eight inclusionary housing units proposed six very low and two low-income units • Total of 154 parking spaces are proposed for 69 residential units and 15,620 square feet of commercial uses. • Two density bonus waivers are currently proposed: waiver to 45-foot height limit and number of stories. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 2 In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans, policies, and standards in effect as ofthe date ofthis review. Please be aware that at the time of a formal application submittal, new plans, policies, and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: General 1. The General Plan and zoning designations for the property are as follows: a. General Plan : Village-Barrio (V-B) b. Zoning: Village-Barrio (V-B) c. Master Plan : The project is located within the Village Center (VC) District of the Village and Barrio Master Plan (VBMP). The permitted density is 28 to 35 dwelling units per acre. d. The project is not located in the Coastal Zone 2. The project requires the following applications, which require approval from the City Council: a. Site Development Plan. Pursuant to VBMP Section 6.3.3(8), an SDP is required for new construction of 5 or more residential units and/or a building larger than 5,000 square feet. b. Tentative Tract Map. If the units are for sale (i.e., condominiums instead of apartments), a tentative tract map will be required. c. Grading and Landscape Plans 3. Proposed Land Use. A mixed-use building is permitted within the VC District per the VBMP, Table 2-1. For an exhaustive list of permitted uses, conditionally permitted, and/or prohibited in the VC District, please consult Table 2-1 beginning on page 2-6 of the VBMP. For an exhaustive list of expressly prohibited uses, please see Table 2-1 on page 2-8. Please see link to VBMP below: 4. https://www.carlsbadca .gov/home/showpublisheddocument/15621/638865445621170000 Density/Density Bonus. The density range for the VC district is 28-35 dwelling units per acre. Absent the density bonus, the maximum number of units that can be permitted on the site is 51. Please see calculation below for reference. Maximum Units permitted for 1.46-acre parcel: 51(exclusive of a density bonus request): Maximum density= 35 du/ac: Maximum unit yield= 35 x 1.46 = 51.1; rounds down to 51 units (required to round down per Carlsbad Municipal Code Section 21.53.230, Table A) The proposal to construct 69 multi-family units results in a proposed density of 47.2 du/ac and therefore exceeds the maximum allowable residential density. A 35% density bonus will be required to construct 69 units. Please see calculation in Housing & Homeless Services Department Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 3 5. 6. 7. for additional information. Please see link to Informational Bulletin, IB 112, for additional information regarding density bonus projects. https://www.carlsbadca .gov/home/showpublisheddocument/8169/638967418316170000 Density Bonus-Incentives/Concessions and Waivers. The concept project proposes a 35% density bonus and requires six very low income inclusionary housing units. Pursuant to State Density Bonus Law, the project is entitled to two incentives/concessions and an unlimited number of waivers. The city must grant a requested incentive/concession unless it finds, under a preponderance of evidence, the following: • The incentive/concession does not result in identifiable and actual cost reductions to provide for affordable housing costs or rents. • Granting the incentive/concession would have a specific adverse impact on public health or safety or on property listed on the California historical register, which cannot be mitigated, or would be contrary to state or federal law. For waivers to development standards: • The developer must provide sufficient documentation justifying why the city's established development standard(s) or design regulation(s) physically preclude construction of the project and why the waiver(s) is necessary. Sufficient documentation may include a written explanation of the physical constraints accompanied by an exhibit showing the site and developable envelope. Please provide sufficient documentation for each density bonus incentive/concession and waiver requested justifying how the project complies with the above-noted findings. For waivers, sufficient documentation should include a written explanation of the physical constraints accompanied by an exhibit showing the site and developable envelope and how the implementation of the standard would preclude the development of the project as proposed. If square footage and/or number of units are impacted, please quantify the loss of square footage/units. Please see link to P-l(H), Density Bonus Report, for additional information. This application shall be included with the initial submittal. P-l(H): https://www.carlsbadca.gov/home/showpublisheddocument/16609/638561251975170000 lnclusionary Housing Requirement. Please see comments from the Housing & Homeless Services Department. In addition, please see the City's lnclusionary Housing Program Information Bulletin for more information: https://www.carlsbadca.gov/home/showpublisheddocument/9634/637897580094270000 Parking/Assembly Bill (AB) 2097. A total of 154 parking spaces are proposed for 69 residential units and 15,620 square feet of commercial use. Pursuant to Assembly Bill (AB) 2097, local jurisdictions located within ½ mile of a major transit station cannot enforce minimum parking Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014}-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 4 requirements. Developers can still provide parking onsite, but the number of parking spaces provided will be based on builder preference and market demand, not by city-established minimum parking standards. However, electric vehicle and accessible parking will still need to be provided based on the number of parking spaces for the commercial and residential uses that would have otherwise been required for the project. Please see link below for additional information: IB-131, AB 2097: https://www.carlsbadca.gov/home/showpublisheddocument/12218/638563690008600000 8. Technical Studies/Exhibits. The following technical studies/reports, beyond those listed as required in Development Permit Application Form P-2, shall be required with a formal submittal. Each of the studies/reports shall be provided in hard copy (2 copies each) and digital : a. Noise Study. A noise study shall be submitted for any residential project requiring a discretionary permit containing five or more dwelling units or any multiple-family dwelling units located within or 500-feet beyond the 60 dB(A) CNEL noise contour line of the Noise Contour Map as part of the Carlsbad General Plan. This project meets both above qualifications. Please provide a noise study in compliance with the City of Carlsbad Noise Guidelines. The city's Noise Guidelines Manual may be found on the city's website at: https://www.carlsbadca.gov/home/showpublisheddocument/238/637425974092370000 The City's General Plan Noise Element (Chapter 5) may be found on the city's website at: https://www.carlsbadca.gov/home/showpublisheddocument/3426/637434861102600000 b. Cultural and Paleontological Resources Studies. The development of the proposed project will require excavation in an area of the city known to have high sensitivity as it relates to (1) archeological, and (2) paleontological resources. Please direct your consultant to the city's Tribal, Cultural and Paleontological Resources Guidelines. Please note that any archeological pedestrian survey of the site for the cultural resources study shall also include a Native American monitor during the survey. The city's Tribal, Cultural and Paleontological Resources Guidelines may be found on the city's website at : https://www.carlsbadca.gov/home/showpublisheddocument/254/637425976516870000 c. Historical Analysis. The existing buildings on the project site appear to have been built over 45 years ago. The development of the proposed project will require demolition in an area of the city known to have a high sensitivity as it relates to architectural history. To determine if the structures are significant pursuant to the California Environmental Quality Act (CEQA), a historical analysis report will need to be submitted or provide documentation that the structures are less than 45 years old. This report shall also be consistent with the city's Tribal, Cultural, and Paleontological Resources Guidelines as discussed above. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 5 9. Please note, this does not represent an exhaustive list. Additional Planning-related studies may be required. In addition, there may be other studies requested by the reviewing City Departments and Divisions listed below. Chapter 2.6 Area-Wide Standards. This project is subject to the Chapter 2.6, Area-Wide Standards of the VBMP beginning on page 2-13, which include but are not limited to the following standards: a. Chapter 2.6.1, Site Planning, Ingress and Egress. Vehicle access shall be taken from the alley where the condition exists. Planning comment: Please redesign project to remove access to Building A off Roosevelt Street. Access shall be taken from the Tyler Street Alley. a. Chapter 2.6.2(A)& (Bl. Building Orientation & Entrances. The Primary Building's main entrance shall front onto and directly access the Primary Street's walkway. Since two detached mixed use buildings are proposed, a lobby fronting the street shall be provided for each building. Building A complies with the entry provided off Roosevelt Street. Building B does not comply as there is not a lobby fronting the street. Please redesign the project to provide an entrance to Building B directly off State Street. b. Chapter 2.6.2(Cl Placement and Orientation. Roof Protrusions. i. All roof structures, including protrusions such as equipment housing and guardrails; parapets and equipment screening; architectural features such as decorative or accent elements and towers; flagpoles; and roof decks and their amenities, shall complement and be consistent with the design of the building. No roof structure shall be taller than the minimum height needed to accommodate, screen, or enclose the intended use. Roof structures specifically for the housing of elevators, stairways, tanks, ventilating fans, or similar equipment required to operate and maintain a building; flagpoles, chimneys, smokestacks, wireless masts and similar structures: Up to 10 feet above maximum height. Please label the height of all privacy walls and mechanical screen walls on the roof plan. Provide elevations to show the roof structures and protrusion complement and are consistent with the building design. ii. The cumulative area devoted to roof structures (excluding roof decks, parapets, solar energy systems and skylights) shall not exceed 10 percent of horizontal roof area. Please show and dimension the roof structures and provide a calculation to show that it will not exceed 10 percent of the horizontal roof area. 10. Chapter 2.7.1-Village Center (VC) Supplemental District Standards. This project is subject to the Chapter 2.7.1 -Village Center (VC} Supplemental District Standards of the VBMP beginning on page 2-36, and as edited by Chapter 2.3 of the VBMP Objective Design Standards beginning on page E-8 which include but are not limited to the following standards. a. Chapter 2.7.l(A) Setbacks. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014}-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 6 i. Front/Corner (property lines fronting Grand Avenue and State Street) - Minimum of O feet, maximum of 5 feet to building at the ground floor. Additional depth permitted where an area includes a plaza, courtya rd, or outdoor dining. Additional depth is also permitted to accommodate electrical transformers, utility connections, meter pedestals and similar equipment only if other locations are infeasible as determined by the decision-maker. Please show the 5-foot maximum setback on the plan ii. Side and Rear-0 feet b. Chapter 2.7.l(E) Open Space. i. ii. Private. Private residential open space shall be provided at a minimum of 60 squa re feet per unit with a minimum dimension of 6 feet in any direction and with more than one (1) open space area . With a formal submittal, please dimension the open space areas and provide a line-item calculation of the open space areas to confirm this requirement is met. Planning comment: It does not appear that all balconies meet this standard. Common. Residential Common Open Space shall be provided for projects with more than 10 units. Common open space shall be provided at a minimum of fifteen (15) square feet per unit with a minimum dimension of ten (10) feet in any direction (not including utilities or storage enclosures located within these spaces). Common open space shall be purposefully designed as active or passive recreational facilities and include one (1) or more of the following: a pocket park, community garden, courtyard, athletic/ recreational courts or gyms, pools and spas, picnic/sitting area accessible to all residents, and play equipment area for children . An applicant may provide common space through an amenity not on this list if it is readily accessible by all residents for recreation and social purposes. c. Chapter 2.7 .l(F) Service and Delivery Areas. Service and loading shall be conducted using alley access where the condition exists. Identify where the service and loading area will be. Given the 20-foot width of the Tyler Street Alley and the upper and lower level parking garages for Building A, it is not clear whether there is a feasible option for trash pickup for both buildings. Further, the Engineering Department has indicated there does not appear to be a dedicated public street for the entire stretch of Tyler Alley as shown on the site plan. These are issues that will need to be resolved prior to formal submittal of the project. d. Chapter 2.7.l(G) Building Height. i. The maximum building height is 45 feet and 4 stories. ii. Ground floor wall plate height: Minimum 14 feet. This height shall be measured from the finished floor to the top plate of the ground floor or, where there is no "plate", to the bottom of the floor structure of the second floo r. This standard shall apply only to the ground floor street frontage uses permitted within the boundaries of the use restriction area identified on Figure 2-2. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014}-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 7 iii. A maximum of 30 percent of the fourth story street facing facade can have a 0-foot setback (as measured from the property line). The remaining 70 percent shall be set back a minimum of 10 feet (as measured from the property line). The total square footage of enclosed fourth floor space shall not exceed 80 percent of the largest enclosed floor space below (floors one, two, or three). However, in no case shall the fourth-floor enclosed space exceed the amount of third floor enclosed space . If use of Density Bonus Concessions or Waivers is proposed to waive these requirements, a waiver and documentation the standards in this letter should be provided per each development standard. e. Chapter 2.7.l(Hl Building Massing. Maximum wall plane and roofline: No building facade visible from any public street (excluding alleys) shall extend more than 40 feet in length without a 5-foot minimum variation in the wall plane, as well as a change in roofline. f. Chapter 2.7.1(1) Ground Floor Street Frontage Uses. New ground floor street frontage uses permitted within the boundaries of the use restriction area identified on Figure 2-2 shall occupy more than one-half of the habitable space developed on the ground floor and shall span at least 80 percent of the building frontage. Up to 20 percent of a building frontage may be used for a lobby or entryway to uses above or behind ground floor street frontage uses . 11. Objective Design Standards. This project is subject to the Village & Barrio Objective Design Standards (ODS) found in Appendix E of the Master Plan. Please see the city's Informational Bulletin and the ODS Compliance Checklist, both linked below. Please submit a completed Compliance Checklist with a formal application submittal. Also, in your formal submittal, please demonstrate in the plans how the project complies (with dimensions, callouts, calculations, etc.) with the objective design standards for the building type and chosen architectural style. Informational Bulletin 302: https://www.carlsbadca.gov/home/showpublisheddocument/15945/638385923722730000 VBMP ODS Compliance Checklist: https ://www .ca rls ba dca .gov /ho me/ showp u b I ished d ocu me nt/ 15309 / 63863 2 7 82040170000 Village and Barrio Master Plan Appendix E: https://www.carlsbadca.gov/home/showpublisheddocument/13754/638312276242470000 a. Please note that there are architectural styles associated with the various subdistricts that will need to be identified, and the proposed design adhered to. Please review your design against the ODS and revise where any non-compliance might occur. b. Pursuant to the Village and Barrio Master Plan Objective Design Standards (VBMP ODS), a large mixed use building in the VC district requires one of the following architectural styles: i. Spanish Revival ii. Craftsman iii. American Mercantile iv. Traditional Modern Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 8 v. California Contemporary Please select an architectural style from the list above and show how the project complies. c. The project is subject to Chapter 2.4 -Applicable VBMP Section 2.8 Area-Wide District Guidelines of the VBMP Objective Design Standards beginning on page E-11 which include but are not limited to the following standards: i. Public utility equipment, meter pedestals, and transformers on private property shall be located a minimum of two (2) feet away from sidewalks and pedestrian areas or underground. Please include dimensions on the plans to demonstrate compliance. ii. Roof mounted mechanical equipment and screening shall not interfere with required solar zones or installed solar photovoltaic or solar water heating systems. This comment is for informational purposes only. iii. Trash, recycling, and mailbox enclosures shall incorporate the materials and colors of the primary building design. Please clarify location and design of mailbox enclosures on the plans. d. This project is subject to Chapter 2.6 -Additional Area-Wide Standards of the VBMP Objective Design Standards beginning on page E-11 which include but are not limited to the following standards: i. Equipment & Utility Screening and Site Design. 1. Wall-Mounted utility elements such as vents, exhausts, wires, conduits, junction boxes, transformers, ballast, backflow devises, irrigation controllers, switch and panel boxes, and utilities such as gas and electrical meters shall be located at interior corners of building walls or behind building or landscape elements and outside of view from a public right-of-way. 2.AII flashing, sheet metal vents, exhaust fans/ventilators, downspouts and pipe stacks shall be painted to match the adjacent roof or wall material and/or color. Please add a note to this effect to the elevations. ii. Bicycle Parking. 1.Short-term Bicycle Parking. Short-term bicycle parking shall be provided in the form of permanent bicycle racks for at least six (6) bicycle parking spots . Racks shall be located within 50 to 100 feet of the primary building's entrance. Bicycle racks and associated bicycle maneuvering shall not impede upon the public sidewalk path of travel and shall not be placed within the public right-of-way. A bike corral may be proposed in lieu of a bike rack if approved by the City of Carlsbad. Please show location of short-term bicycle parking on the plans. 2. Long-term Bicycle Parking. Projects of More Than Ten (10} Units. Long-term bicycle parking shall be provided for projects of more than ten (10} units. Secure, long-term bicycle parking areas shall be enclosed and designed within a residential building or parking structure, or within a separate lockable storage enclosure. Long-term bicycle parking facilities shall incorporate materials and colors used in the primary building Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 9 12. 13. 14. 15. and shall not be visible from the public right-of-way. Please show the location of long- term bicycle parking on the plans. iii. Private Open Space Screening. Where private open space (such as a balcony or ground floor patio) is located adjacent to a window, patio or balcony of an adjoining dwelling unit, balcony railings and patio walls or fencing shall be constructed with wood, composite wood, metal, or glazing. Screening shall be constructed with limited openings to provide a minimum of eighty-five {85%) percentage surface area screening (measured from the finished floor of the private space to the top of the railing, fencing, or walls). Please indicate railing/fencing material and height for all balconies. Electrical Transformer. Please submit correspondence from SDG&E indicating whether a transformer will be required . If required, please identify the location on the plans and provide landscape screening. Solid Waste. Please provide a "will serve" letter for waste hauler services for the project with a formal application submittal. Send request to: Carlsbadservice@RepublicServices.com. General Planning/Site Design Comments. Please consider the following site design comments as part of the revisions that will be needed for the concept project: a. An entrance to the residential lobby for Building B shall be provided directly off State Street so residents/guests are not forced to walk through a narrow corridor in between buildings to enter the building. b. The Utilities Department's requirement for a 20-foot-wide sewer easement will impact the size/design of the parking garage for Building B. No structures can be in the easement. c. Approval from adjacent property owners may be needed for additional dedications associated with the Tyler Street Alley. Please see comments from LDE For additional information. d. Every effort shall be made to retain all existing, mature street trees e. Since the Tyler Street Alley is less than 24 feet in width, the Fire Department will not be utilizing the alley for access in an emergency. Please see comments from Fire for additional information. f. Please check with Republic Services to confirm the company will be able to utilize the alley for access since it is only 20 feet wide. g. The required State Street ROW dedication will likely require a reduction in the footprint for Building B. h. For all parking stall series with a dead -end, please include a parking stall marked for "No Parking-Turn-Around Area Only." Please refer to the CMC Chapter 21.4, Parking Ordinance, for information regarding the minimum dimensions and maximum number of compact spaces that can be permitted. City Council Policy 84. Early Public Notice and Stakeholder Outreach. The project is subject to City Council Policy Statement No. 84, Development Project Public Involvement. Please review City Council Policy No. 84, as early public notice and enhanced stakeholder outreach requirements are required. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 10 16. 17. An early public notice is required to be prepared by the applicant and mailed to all owners and a notice sign is required to be posted onsite by the applicant within 30 days of the application submittal date. In addition, the applicant is required to complete enhanced stakeholder outreach to further engage the community on their project. Project applicants shall conduct at least one in- person public outreach meeting with the community. Additional meetings are encouraged and recommended but not required . The Draft Development Project Public Involvement Package must be submitted at the time of the application submittal. Applicants are encouraged to begin engaging and soliciting public input prior to application submittal, however outreach conducted prior to submittal does not satisfy the requirements of the policy. Housing Crisis Act. The Housing Crisis Act of 2019 (SB 330) established a preliminary streamline application process for housing projects. It is not mandatory unless applicants seek the vesting and processing benefits offered under SB 330. Participation in the SB 330 streamline process would occur first, followed by the formal development application process required under Government Code (Gov. Code) §§ 65940, 65941, 65941.5, and Carlsbad Municipal Code (CMC) § 21.42.050. Acceptance by the city of a complete SB 330 Streamline Application (Form P-32) and fee will vest the project for 180 days in accordance with the ordinances, policies and standards in effect at the time the SB 330 Application is accepted. Climate Action Plan. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely impact development requirements of this project. A formal application submittal will need to include a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand management requirements, as set forth in the California Green Building Standards Code and in Carlsbad Municipal Code Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the following address:http://www.qcode.us/codes/carlsbad/view.php?topi c=18&frames=on To the extent that new GHG reduction requirements are in effect at the time of application for grading or building permits, the project will be required to comply with the effective requirements even if different than what is proposed in the project's planning approvals. GHG reduction requirements may impact, but are not limited to, site design and local building code requirements. If incorporating new GHG reduction requirements results in substantial modifications to the project after planning approvals are obtained, then prior to issuance of grading or building permits, the applicant may be required to submit and receive approval of a Consistency Determination or an Amendment application for the project through the Planning Division. 18. Changes following entitlement. Chapter 21.89 of the city's Municipal Code outlines the level of changes that can be approved post entitlement, and those that are required to process a Substantial Conformance Review. Any changes following a discretionary approval must be entirely consistent with the approved discretionary permits or meet the objective standards in this code section. Additionally, any design changes that make modifications to increase the conflict between an objective standard will be difficult to approve when the project approval was based on use of a density bonus to deviate from the objective standards. It is strongly recommended Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014) -ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 11 design choices are considered for feasibility and cost prior to entitlement so that either a Substantial Conformance Review is not needed, which could be appealed, or re-entitlement is not needed. Land Development Engineering: Nichole Fine, 442-339-2744, Nichole.Fine@carlsbadca.gov 1. Contact Nick Gorman in the Transportation Division at Nick.Gorman@carlsbadca.gov , a division of the Public Works Department, to determine if a Scoping Agreement is required. Scoping Agreements are used to determine if a Local Mobility Analysis (LMA) is required and the scope of analysis. If an LMA is deemed necessary, first, work with Transportation Division staff to obtain an approved scoping agreement. After the scoping agreement has been approved, submit the approved Scoping Agreement as an appendix within the LMA that is to be prepared per the most recent Transportation Impact Analysis Guidelines. 2. After the scoping agreement has been approved or deemed not necessary by the Transportation Division, submit a completed Transportation Analysis Need Statement Form P-42 to Land Development Engineering at LandDev@carlsbadca.gov prior to discretionary application submittal. If an LMA has been deemed not necessary by the Transportation Division, please provide correspondence from the Transportation Division indicating one is not required . 3. A Transportation Demand Management (TDM) plan may be required depending on the number of employee vehicle trips the project will generate. Calculate the gross employee ADT using the generation rates from Table 2-2 of the TDM Handbook at: https://www.carlsbadca .gov/home/showpublisheddocument/310/637425981338370000 Show calculations on the Climate Action Plan checklist, Form P-30. If applicable, submit a TDM plan with your application for discretionary permits. 4. Depending on the CEQA determination, which is determined after the application for discretionary permits is submitted, a Vehicle Miles Traveled (VMT) analysis may be required per the Vehicles Miles Traveled Analysis Guidelines available at: https://www.carlsbadca.gov/home/showdocument?id=312. 5. Complete a Stormwater Standards Questionnaire Form E-34, https://www.carlsbadca .gov/home/showpublisheddocument/604/638683035715330000. This questionnaire will guide you and the city in determining what type of reports and storm water mitigation must be completed to satisfy state and City storm water quality requirements. The questionnaire is located on the City of Carlsbad website. 6. Based on a preliminary analysis it appears that this project is a Priority Development Project (PDP). All impervious surfaces being created or replaced (onsite and offsite) shall be included for treatment. Submit a Storm Water Quality Management Plan. This project is exempt from Hydromodification. The post construction stormwater treatment BMPs shall be shown on a conceptual grading plan and drainage plan with the discretionary application. 7. Based on this project's general land use V-B, this project is subject to the City of Carlsbad trash capture requirements. Incorporate trash capture measures on the project plans. Incorporate Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 12 8. 9. 10. 11. 12 . 13. 14. 15. 16. 17. 18. 19. 20. trash capture calculations into the Storm Water Quality Management Plan. Provide a Preliminary Title Report (current within the last six (6) months). Annotate and delineate all existing easements and encumbrances listed in the Preliminary Title Report on the site plan. If any vacations or quitclaims are planned with this development annotate on the site plan. A Preliminary Hydrology Study including map and calculations is required to demonstrate capacity/sizing of proposed and existing storm drain infrastructure. Show 100-year storm hydrologic calculations before and after development for each drainage basin. Show how the storm water run-on from offsite will be conveyed through the project site. A preliminary geotechnical report is required to evaluate the feasibility of the project, provide infiltration feasibility and remedial recommendations. Guidelines for preliminary geotechnical studies are available on the City of Carlsbad Engineering website through the following link: https://www.carlsbadca.gov/home/showpublisheddocument/326/638054006747270000. Per CMC15.16.060 this project will require a grading permit and grading plan. A separate improvement plan for work within the right-of-way is required for this project. This project shall utilize City of Carlsbad Survey Control Network established on Record of Survey Map 17271, NAD83, Zone VI, 1991.35 Epoch for horizontal control and NGVD 29 datum for vertical control per City of Carlsbad Engineering Standards. Delineate and annotate the limits of grading. Delineate and annotate approximate topographic contours for existing and proposed condition. Provide 1-foot contours for slopes less than 5%; 2' intervals for slopes between 5% and 10%, and 5' intervals for slopes over 10%. Extend contours a minimum 25 feet beyond the project boundary. On the site plan, show and identify all existing surface improvements screened back (curb, gutter, sidewalk, paving, manholes, inlets, streetlights, adjacent driveways, vaults, transformers, etc.) at the project site, project frontage and within 25 feet of the boundary. Delineate location of all existing and proposed buildings, walls, fences and permanent structures onsite and within 25 feet of the site. Indicate the earthwork quantities (cut, fill, import, export, remedial) proposed for the project in cubic yards. Provide spot elevations at the corners of each pad in the proposed condition. Include finish pad and floor elevations. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 {DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 13 21. Provide the method of draining each lot. Unless otherwise specified by a geotechnical engineer, method of drainage shall comply with California Building Code (latest version) section 1804.4. 22. Delineate all retaining walls that will be utilized on the project site and show top of wall and bottom of wall elevations, including at the highest and lowest points. Indicate maximum height of retaining wall measured from bottom of footing to top of wall and maximum height measured from finish surface to top of wall. 23. The trees along Roosevelt and State Street, and Grand Avenue frontage are included in the city's street tree inventory. Indicate on the site plan that they are to remain or to be removed. Proposed removal of street trees will require approval per Section 11.12.090 of the Carlsbad Municipal Code. Coordinate with the parks and recreation department for additional information. 24. Show existing lot line bearing and distance. 25. An adjustment plat with a certificate of compliance will be required for the lot consolidation. 26. Show location and dimensions of all accessways and pathways as required for compliance with Title 24-State Accessibility Requirements. 27. Provide typical street cross sections for existing frontage streets for Grand Avenue, State Street and Roosevelt Street. Provide existing right-of-way width and existing improvements and proposed improvements and dedications. 28. Delineate and annotate all proposed driveways and driveway widths. 29. Driveways that exceed more than 150' length shall have a turnaround designed for a 3-point turn of a passenger vehicle. Additionally, applicant shall coordinate with the fire department to ensure width and grade of alley meets fire department requirements. 30. Show truck turning radii. Plot turning radii per Caltrans figure 404.5B and/or 404.SF. 31. Provide 5-foot minimum back-up clearance at the last stall of the row of parking spaces. 32. Show all existing and proposed utilities and callout size for: water, sewer, storm drain, underground dry utilities, overhead lines, traffic signals, streetlights in Roosevelt Street, Grand Avenue, State Street, and Tyler Alley and laterals affecting the property. Include the existing 8" VCP sewer constructed per Dwg.408-3 through the Tyler Alley. 33. All transformers and electrical facilities solely serving this project site shall be located on site and outside of the public right-of-way 34. Obtain a letter from SDG&E confirming their approval of the proposed transformer location and stating that no additional off-site facilities will be necessary for this project. Please also include all existing and proposed dry utilities and the services that will supply power to the proposed transformer. Community Development Department Planning Division [ 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 14 35. Provide a Sewer Study for new development based on City of Carlsbad Sewer Master Plan Update 2019, Section 4.2 Design Criteria. 36. Provide a Water Study for the new development based on City of Carlsbad Potable Water Master Plan 2019, Section 4.2 Design Criteria. 37. Public potable water and sewer mains along project frontages must meet minimum design diameter and material as specified in City of Carlsbad Engineering Standards Vol. 2 Section 3.2.2 for water and Volume 1 Section 6.2 for sewer. Utility replacement and/or upsizing may be required as a condition of development. 38. Locate fire service, backflows, potable and recycled water services, meters, landscape irrigation services, and sewer laterals for the new development in compliance with City of Carlsbad Engineering Standards requirements. 39 . Ensure the trash enclosure design is consistent with the City of Carlsbad and Republic Services standards, see building department form B-76. 40. Provide multiple cross-sections of the site to demonstrate differences in grade from adjacent properties, existing and proposed grades on-site, fences and location of structures on-site and on adjacent properties. 41. Dedications and frontage improvements are required per CMC18.40 and CMC20.16. Provide dedication on Roosevelt Street for 36-foot half width. It appears that the 11-foot dedication on the site plan accomplishes this request. Provide street cross sections to clarify half width with the discretionary application. Additional right-of-way may be required to facilitate the update of the curb ramp to ADA standards on the corner of Grand Avenue and Roosevelt Street. 42. Provide dedication along State Street to maintain a 40-foot half width, consistent with existing right-of-way width on the south side of the project. Re-align curb, gutter, sidewalk and relocate utilities to facilitate additional diagonal parking at the project frontage. See redlines on the site plan. 43. Provide 10-foot wide minimum sidewalks along Roosevelt Street and State Street along the project frontage. 44. Meet with the Fire Department to identify the necessary fire protection measures required for this project (access, fire hydrants, sprinkler system, on-site circulation, emergency access, etc.) 45. Plot stopping sight distance at all driveways and corner sight distance at all street intersections. 46. There does not appear to be a dedicated public street for the entire stretch ofTyler Alley as shown on the site plan. Which appears to be primary access for the restaurant parking. Either provide the existing recorded dedication information for public street or alternatively provide agreement from owners where no existing dedication exists with your discretionary application. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 15 47. Address the comments on the attached redlined plan. 48. Please be advised that a more in-depth review of the proposed development will occur with the discretionary permit application when a more complete design of the project is provided. Fire Department: Darcy Davidson, 442-339-2662, darcy.davidson@carlsbadca.gov 1. Unable to conduct a thorough review since some information is missing. Upon project submittal, please include a Fire Master Plan for review. The plan shall include, at a minimum, the following elements: • Square footage, building height, construction type, and occupancy type of all buildings. • Fire department access roads and dimensions, road surface material, and access gates (if any). • Aerial fire apparatus (ladder truck) access is required. Show aerial apparatus access points to the roof, taking into consideration obstructions such as street trees and overhead wires. • Hose-pull dimensions to all structures. Hose-pull measurement begins at a point in the fire access road where fire apparatus would park to perform emergency operations. If access is taken from a public street, measurement shall be taken 10 feet from the edge of the curb. Hose-pull measurement is required to be no greater than 150 feet to all portions of the exterior of the first floor of any structure. • Hydrant locations. Hydrants shall be provided along the length of the fire access roadway in the quantities and up to the maximum distances prescribed in CFC Table C 102.1 and in accordance with the approved Form P99-F. • Location of fire riser(s), riser room, and alarm panel. • Ladder pad locations for all emergency escape and rescue openings. 2. Aerial Fire Apparatus Access (ladder truck) shall be provided when the distance from grade plane to the highest level of the roof exceeds 30 ft. The aerial access road must be a minimum of 15 feet and a maximum of 30 feet from the building and shall be positioned parallel to one entire side of the building. 3. Hose-pull distance is not shown and likely exceeds the allowed distance of 150 feet. A fire apparatus access roadway must extend to within 150 feet of all portions of the exterior of the first floor of all buildings. This allows for adequate firefighting operations and hose-pull from the fire apparatus. Hose-pull measurements begin at a point in the street located 10 feet from the edge of the curb. Show hose-pull measurement on the plans and demonstrate can reach all points of the first floor of the buildings within 150 feet. 4. Tyler Street is only 20 feet in width and will not be considered a fire access road since it does not meet the minimum width requirement of 24 feet. 5. Sleeping rooms below the fourth story above grade plane shall have not fewer than one exterior emergency escape and rescue opening (EERO). Access via ground ladders to above-ground windows shall be provided. Such openings shall open directly into a public way or to a yard or court that opens to a public way. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 16 6. Ladder pads for Emergency Escape and Rescue Openings (EEROs) shall meet the following requirements: • A ladder pad shall be provided to access every EERO above ground level. • The ladder pad shall be located at a distance from the building determined by measuring the required length of the ladder at the proper climbing angle. The measurement is made with the top of the ladder leaning against the emergency rescue opening and the foot of the ladder on the ground. The ladder angle is to be at least 70 degrees and no greater than 76 degrees. • Ladder pad shall be sized 6' by 6' minimum to allow for 3 feet of working space in front, behind, and around the ladder. • The surface shall be one that lends itself to safe use of ground ladders. Surface shall be level, slip-resistant, and capable of supporting the loaded weight of the ladder in a rescue operation. Solid all-weather surface walkways such as concrete or asphalt are preferable, though alternative surfaces such as decomposed granite (DG), gravel, or grass are permissible under certain conditions. • Clearly show all ladder pads on the plans 7. Confer with CMWD regarding water supply and possible need to upgrade water main on Roosevelt. 8. Please submit a completed P99F form to determine fire flow requirements, and to determine the number and location of required hydrants. Please note this must be completed prior to submittal of a formal application for the city for the project. A completed, city-reviewed P99F shall accompany a formal project application to the Planning Division. Building: Jesse Sanchez, jesse.sanchez ctr@carlsbadca.gov 1. Project Funding: Please indicate whether the project is publicly or privately funded . Federal guidelines and CBC Chapter 118 shall apply for publicly funded projects. 2. Provide a completed Climate Action Plan (CAP) Consistency Checklists (city forms B-50). 3. The Project Description indicates two mixed-use residential condominium and commercial buildings that are five-stories tall with subterranean parking. Address the following comments: a) Identify the occupancy groups that will be proposed for the building. CBC 302. b) Identify the Type of Construction of the building per CBC Table 601. Type V-B is limited to three stories max per CBC T504.4. c) Provide an allowable building area and height analysis per CBC 503, 504, 506, and 508 or provide a detailed narrative describing how the building will meet the allowable building area and height provisions of CBC Chapter 5. d) For this site, please show whether these buildings were analyzed as one building or multiple buildings on the same lots per CBC 503.1.2 and 705.3. 4. Fire Separation Distance: Address the following comments: a) Dimension of the distance of each building exterior wall to the assumed property line. b) Exterior walls within the required fire separation distance shall be fire rated per CBC table 705.5. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 17 c) Review the amount of glazing (aka openings) along the exterior wall that fronts the interior property lines. The percentage of openings along the exterior walls shall be limited based on the fire separation distance per CBC Table 602 and Table 705 .8. d) Projections from the exterior walls, such as the roof overhangs, shall be limited based on CBC Table 705.2. Check the distance of the projections from the interior property lines. e) Provide parapets or identify which exception to parapets will be used. CBC 705.11. 5. Parking Garage Provisions: The proposed parking garage appears to be an open garage. Address the following: a) Provide an analysis of the openings to demonstrate how the garage complies with CBC 406.5. b) Provide a narrative describing how the garage levels will be ventilated per CMC 403.7. Include information on where garage exhaust will terminate as garage exhaust is considered product conveying and shall comply with CMC 502.2.2. c) Ensure the analysis accounts for the exterior cladding as it effects the openings to the garage. 6. Accessible parking spaces shall be provided in accordance with CBC Table llB-208.2 for each parking lot or facility. Provide calculation to show compliance. 7. Provide number of EV charging per CGBSC 5.106.5.3. and number of accessible EV charging stations per CBC Table 228 .3.2.1. Utilities: Markus Mohrle, 442-339-2322, Markus.Mohrle@carlsbadca.gov 1. Submit a separate water study for each building proposed by this project, with each to include domestic meter and fire sizing criteria, as well as modeling of the public distribution system in response to on-site water demands (domestic, irrigation, and fire) per the applicable NFPA fire flow requirements the current CMWD Potable Water Master Plan. a. Existing 6-inch ACP water main in Roosevelt Street is undersized and shall be upsized along project frontage to 8-inch PVC as a condition of approval. b. Separate service connections shall be required for residential, commercial, irrigation, and fire service to each building and appropriate frontage space will be required for each . 2. Submit a separate sewer study for each building proposed by this project, with each analyzing the existing and proposed demands on the public sewer main in accordance with the current City of Carlsbad Engineering Standards. a. Existing 6-inch VCP sewer in Roosevelt Street is undersized and shall be upsized along project frontage to 8-inch PVC as a condition of approval. b. Carlsbad has an existing public sewer main between Beech Ave . and Grand Ave. in the Tyler Street Alley alignment along the back property lines of the. This sewer main shall require improvements and a 20-foot-wide sewer easement centered over the main granted to the City of Carlsbad as a condition of approval. c. Developer shall be required to submit a hydraulic sewer modeling request to evaluate potential off-site sewer impacts resulting from this proposed development. d. Separate sewer laterals shall be required for residential and commercial units, and any retail space(s) for food service establishments shall be required to provide FOG separation per Carlsbad Municipal Code 13.06. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014}-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 18 3. Provide updated Civil Site Plan identifying all public utilities along project property lines and indicating utility connection locations, meter and backflow sizes, and piping arrangements detailed up to the back flow preventers or cleanouts based on flow demands or sewer loading estimates. All connections to the public utilities shall be detailed on plans in accordance with current city engineering standards and clearance requirements. See additional red-line markups on attachment. 4. Proposed Ground floor layout shall preserve suitable locations and space for all required utility connections, meters, and backflow devices in conformance with current Engineering Standards. Identify locations and detail fire service, water, irrigation, and sewer connections at property line for the new development in compliance with current Carlsbad Engineering Design Standards and clearance requirements. Housing & Homeless Services: Nicole Piano-Jones, 442-339-2191, nicole.pianojones@carlsbadca .gov 1. 2. 3. Existing conditions. The project is proposing demolition of existing structures. Please provide evidence that no part of the property was used for residential purposes within the last five years of the application date. Density Bonus -Applicant is applying for incentives, and waivers in accordance with density bonus provisions found in Government Code §65915 and Carlsbad Municipal Code Chapter 21.86. The project is proposing six (6) very low-income units, which satisfies this requirement. A Acreage 1.456 B Max Density per Acre 35 C Base Density (Ax B) 1.456 X 35 = 51 units D Requested Bonus {35% x C) 35% x 51 Base Units 18 units E Total Allowable (C + D) Base+ Bonus 69 F Required Affordable Units per GC 51 X 11% = 6 very low-income units 65915 {C X 11%) G Required Affordable Units Per CMC 51 X 12 .5% = 6 very-low-income units 21.85 (51 X 12.5%) H Total Affordable Unit Count (The 6 very low-income units higher of For G) lnclusionary Requirement-The project is also subject to Carlsbad Municipal Code 21.85 . Because the project proposes to provide affordable units at the very low-income level, the 12.5% affordability requirement applies. The project has proposed six (6) very low-income units, which satisfies the inclusionary requirement. Per 21.85.140, an affordable housing agreement will be required for this project. Per 21.85.040(D), the affordable units shall be provided in the same tenure as the market rate units, consistent with California Civil Code 714.7. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014)-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 19 Per 21.85.040 (E), inclusionary ownership units shall remain affordable to subsequent income eligible buyers pursuant to a resale restriction with a term of thirty years. Per 21.85.040 (G), inclusionary units shall be reasonably consistent or compatible with the design of the total project in terms of appearance, materials, and finished quality, including private open space and parking. The project proposes to provide 154 parking spaces. How will the parking spaces be allocated to the residential units? Parking shall be provided for the affordable units in the same proportion as the market rate units. Additionally, the parking spaces for the affordable units will be included in the recorded deed restriction on the property, and unable to be separately conveyed from the unit to which it is assigned. Per 21.85.040. H., bedroom count and unit sizes of affordable units to be commensurate with market-rate units. Please provide details on bedroom counts, specifying the number of affordable units. Affordable housing cost for the affordable units is determined by California Health and Safety Code Section 50052.5. 4. Affordable Unit Distribution -Health and Safety Code Section 17929 ("AB 491") requires the affordable units not be isolated to a specific area or floor. The law also requires that occupants of affordable units be provided with same access to common areas, entrances, and amenities as the market-rate occupants. Please identify the affordable units on the plans to verify compliance with these requirements. Parks & Recreation: Nick Stupin, 442-339-2527, Nick.Stupin@carlsbadca .gov 1. Submittal Requirements per the City of Carlsbad Landscape Manual. This includes but is not limited to: a. Conceptual Landscape Plan b. Conceptual Water Conservation Plan c. Conceptual Fire Protection Plan d. Conceptual Maintenance Responsibility Matrix 2. Plans are subject to the City of Carlsbad's Landscape Manual. As such, please ensure that Section 3, Preliminary Concept Plans is complied with and that the submitted plans meet all applicable city policies. For example, one of these requirements is that the 2016 City of Carlsbad Landscape Manual states in Section 6 that projects should provide a minimum of one (1) tree for every 40 feet of street frontage. a. The current frontage of the project is approximately 310' along Roosevelt Street, approximately 106' along Grand, and approximately 114.5' along State Street. This would require the project to have a minimum of EIGHT (8) trees to be installed along Roosevelt Street, THREE (3) trees to be installed along Grand Avenue, and THREE (3) trees to be installed along State Street, all within the public right-of-way. b. Please ensure that site utilities do not conflict with the placement of new or existing street trees. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2026-0008 (DEV2026-0014}-ROOSEVELT GRAND AND STATE MIXED USE March 25, 2026 Pa e 20 Attachments: 1. Community Forest Management Plan a. https://www.carlsbadca.gov/home/showpublisheddocument/1998/6374338461474300 00 2. City Council Policy 4 3. Landscape Manual a. https://www.carlsbadca.gov/home/showpublisheddocument/11160/637985942877070 000 All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or online at https://www.carlsbadca.gov/departments/community-development/planning. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown. Please review all information carefully before submitting. If you would like to schedule a meeting to discuss this letter with the commenting departments, please contact Shannon Harker at the number below. You may also contact each department individually as follows: • Planning Division: Shannon Harker, Senior Planner, at (442) 339-2621 • Land Development Engineering: Nichole Fine, Senior Engineer, at (442) 339-2744 • Building Division: Jesse Sanchez, contractor, at jesse.sanchez clt@carlsbadca.gov • Fire Department: Darcy Davidson, Division Chief/Fire Marshal, at (442) 339-2662 • Utilities: Markus Mohrle, Senior Engineer, at (442) 339-2322 • Housing & Homeless Services: Nicole Piano-Jones, Senior Program Manager, at (442) 339-2191 • Parks & Recreation : Nick Stu pin, Parks Planning Manager, at (442) 339-2527 Si~~ , _______ _ ERIC LARDY, AICP Assistant Director of Community Development EL:SH :cf Attachments: Land Development Engineering Redlines Utilities Redlines c: Brian Caine, Carlsbad One LLC, PO Box 594, Solana Beach, CA 92075-0594 Nichole Fine, Project Engineer Laserfiche/File Copy Data Entry Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600