Loading...
HomeMy WebLinkAboutDWG 551-9A; MS 2024-0006; CARLSBAD BOULEVARD HOMES; 01-06PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4169 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. 6 THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, NAD 83 (CCS83) EPOCH 1991.35, ZONE 6, AS DETERMINED LOCALLY BY A LINE BETWEEN FIRST ORDER CONTROL STATIONS 136 AND 130 BEING A GRID BEARING OF N 27°20'57" E AND DISTANCE OF 20576.73' AS DERIVED FROM GEODETIC VALUES SHOWN ON RECORD OF SURVEY 17271, CITY OF CARLSBAD SURVEY CONTROL. QUOTED BEARINGS FROM REFERENCE MAPS OR DEEDS MAY OR MAY NOT BE IN TERMS OF SAID SYSTEM. DISTANCES SHOWN HEREON ARE GROUND, UNLESS SHOWN OTHERWISE TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON: MARCH 14, 2024 BY: PASCO, LARET, SUITER & ASSOCIATES TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS. 1. ACTUAL STRUCTURAL SECTIONS WILL BE DETERMINED AFTER "R" VALUE TESTS HAVE BEEN CONDUCTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, ON THE PREPARED BASEMENT SOIL. THE "R" VALUE TESTS AND THE ENGINEERED STRUCTURAL SECTION MUST BE SUBMITTED TO THE ENGINEERING INSPECTOR FOR REVIEW AND APPROVAL A MINIMUM OF TWO (2) CITY WORKING DAYS BEFORE THE WORK BEGINS. 2. STREET LIGHTS SHALL BE INSTALLED AS SHOWN ON THESE PLANS, UNDERGROUND CONDUIT RUNS, SERVICE POINTS AND HAND-HOLES SHALL BE SHOWN ON THE "AS-BUILT" PLANS. NO DIRECT BURIAL STREET LIGHT FOUNDATIONS WILL BE ALL LUMINAIRES SHALL BE "CUT OFF" TYPE ALLOWED. 3. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF CURBS, CROSS GUTTERS OR SURFACING OF STREETS. 4. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 5. WHEELCHAIR RAMPS SHALL BE INSTALLED PER REQUIREMENTS OF TITLE 24, CALIFORNIA ADMINISTRATIVE CODE. 6. STREET TREES SHALL BE INSTALLED PER SECTION VI OF THE CITY OF CARLSBAD LANDSCAPE MANUAL. 7. FIRE HYDRANT MARKERS SHALL BE PLACED IN THE STREET WITHIN THE LIMITS OF WORK OF THIS PLAN PER SDRSD DWG M19. 8. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTURBED BY THIS WORK SHALL BE REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS ACT. 9. TWO (2) SETS OF SURVEY (CUT) SHEETS SHALL BE PROVIDED TO THE CITY ENGINEERING INSPECTOR. 10. STREET LIGHTS SHALL BE 5,500 LUMEN (40 WATT) OR 13,700 PUPIL LUMEN (100 WATT) HIGH EFFICIENCY INDUCTION LIGHTS. 1 TITLE SHEET 2 GRADING PLAN 3 SECTIONS AND DETAILS 4 TIER 2 SWPPP COVER SHEET 5 TIER 2 SWPPP 6 RETAINING WALL PLAN THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS AND FILLS, REMEDIAL GRADING, DRAINAGE FACILITIES, EROSION CONTROL FACILITIES, AND PLANTING OF PERMANENT LANDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND REPORTS, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS, SPECIFICATIONS, REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS. THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. 5211 CARLSBAD BOULEVARD CARLSBAD, CA 92008 APN: 210-062-09-00 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS 3. THIS SET OF PLANS 4. RESOLUTION NO _____ DATED _____ 5. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK) 6. SOILS REPORT AND RECOMMENDATIONS BY GEOTECHNICAL EXPLORATION, INC: JOB. NO. 24-14681 DATED 6/17/2024, REVISED 6/18/2025 7. THE SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDITIONS DATED _________ 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED________ 10. STORM WATER POLLUTION PREVENTION PLAN (TIER 2) PREPARED BY: ___________ , SEE SHEETS 4-5, DWG 551-9A. SW NO. ________ WDID NO. _________ 11. STORM WATER QUALITY MANAGEMENT PLAN PREPARED BY: ___________ DATED: _______________ 12. CALIFORNIA STORM WATER QUALITY ASSOCIATION BMP CONSTRUCTION HANDBOOK AND CALTRANS CONSTRUCTION SITE BMP MANUAL PLSA N/A N/A N/A ABBREVIATION: SDRSD - SAN DIEGO REGIONAL STANDARD DRAWING CMWD - CARLSBAD MUNICIPAL WATER DISTRICT * NOTE: MODIFIED PER CITY OF CARLSBAD STANDARD LOT 33 OF TERRAMAR UNIT NO. 1, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 2696, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, SEPTEMBER 6, 1950. N/A IN SOUTHEAST CORNER OF DRAINAGE BOX INLET AT THE END OF CURB RETURN IN THE NORTHEAST CORNER OF GRAND AVENUE AND WASHINGTON STREET, 52 FEET WEST OF RAILROAD TRACKS AND 40 FEET NORTH OF THE CENTER OF GRAND AVENUE. DESCRIPTION: 2.5" BRASS DISK LOCATION: RECORDED: ELEVATION: 40.91 DATUM: NGVD29 MAP 2696 ROS 9595 CR 52518 BF = BOTTOM OF FOOTING ELEVATION EG = EXISTING GRADE FS = FINISHED SURFACE FG = FINISHED GRADE FL = FLOWLINE FF = FINISHED FLOOR GLIP = GARAGE LIP ELEVATION IE = INVERT ELEVATION LA = LANDSCAPE AREA TC = TOP OF CURB TG = TOP OF GRATE ELEVATION RIM = TOP OF RIM ELEVATION EXISTING GRADE FYSB = FRONT YARD SETBACK RYSB = REAR YARD SETBACK SYSB = SIDE YARD SETBACK NAME: JOHN NORUM FOR: THE TIDES AT TERRAMAR LLC ADDRESS: 2888 LOKER AVENUE EAST, SUITE 220 CITY, ST.:CARLSBAD, CA 92008 PHONE NO.:(949) 678-4927 EMAIL:JOHN@KMJRE.COM N/A N/A TBD TBD 1 X X W W S S G G SD SD X X E E 277 LF 133 LF PROPERTY BOUNDARY CENTERLINE OF ROAD ADJACENT PROPERTY LINE PUBLIC RIGHT-OF-WAY SETBACK LINE EXISTING CONTOUR LINE PROPOSED CONTOUR LINE PROPOSED FLOWLINE PROPOSED DIRECTION OF FLOW PROPOSED STEM WALL / PORTION OF BUILDING TO RETAIN PER SEPARATE ARCH PLAN PROPOSED DEEPENED FOOTING PER SEPARATE ARCH PLAN PROPOSED ORCO MASONRY RETAINING WALL W/ FENCE PROPOSED GRAVITY RETAINING WALL PER SDRSD C-9 PROPOSED 8" PRO SERIES CHANNEL DRAIN BY NDS OR APPROVED EQUAL PROPOSED GRAVEL STORAGE BASIN DETENTION SYSTEM PROPOSED PCC PAVEMENT PROPOSED VEHICULAR PERVIOUS PAVERS PROPOSED PEDESTRIAN PERVIOUS PAVERS PROPOSED FLUSH CURB EXISTING FENCE EXISTING WATER MAIN (SIZE PER PLAN) EXISTING SEWER MAIN (SIZE PER PLAN) EXISTING GAS MAIN (SIZE PER PLAN) EXISTING ELECTRICAL PROPOSED PRIVATE STORM DRAIN PIPING; SIZE AND MATERIAL PER PLAN PROPOSED PVC PRIVATE STORM DRAIN PERFORATED PIPING; SIZE PER PLAN PROPOSED 6" AREA DRAIN PROPOSED BROOKS BOX PROPOSED ROOF DOWNSPOUT 915 SF 546 CF 915 SF 697 SF 514 SF 2 EA 5 EA 5 EA 8 EA ALL STANDARD DRAWINGS ARE SAN DIEGO REGIONAL STANDARD DRAWINGS (SDRSD) UNLESS NOTED OTHERWISE: * CITY OF CARLSBAD STANDARD ** CARLSBAD MUNICIPAL WATER DISTRICT STANDARD DRAWING *** SDRSD AS MODIFIED BY CITY OF CARLSBAD IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15.16 OF THE CARLSBAD MUNICIPAL CODE. 1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF-WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE AS WELL AS ADDITIONAL INSURED ENDORSEMENT MUST BE FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $2,000,000.00 FOR EACH OCCURRENCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HAVE A RATING OF "A-" OR BETTER AND A SIZE CATEGORY OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RATING GUIDE. 5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER APPROPRIATE AGENCIES. 6. REVISION OF THESE PLANS MAY BE REQUIRED IF THE PROPOSED IMPROVEMENTS ARE NOT CONSTRUCTED PRIOR TO THE DEADLINE DATE OF THE IMPROVEMENT AGREEMENT. 7. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK OR GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HAS BEEN OBTAINED AND A VALID GRADING PERMIT HAS BEEN ISSUED. 8. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND THE TITLE SHEET. 9. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 10. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 11. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 12. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF THE COMPLETION OF FIELD TESTS. 13. A SOILS COMPACTION REPORT AND COMPLIANCE VERIFICATION REGARDING ADHERENCE TO RECOMMENDATIONS OUTLINED IN THE SOILS REPORT IS REQUIRED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE FILL AREAS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIFICATIONS AND THE "EARTHWORK SPECIFICATIONS" ATTACHED TO THE PRELIMINARY SOILS INVESTIGATION. DAILY FIELD COMPACTION REPORTS WILL BE SUBMITTED TO THE PROJECT INSPECTOR. 14.A PRECONSTRUCTION MEETING SHALL BE HELD PRIOR TO THE BEGINNING OF WORK AND SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK. THE CONTRACTOR WILL BE CONTACTED BY THE PROJECT INSPECTOR TO COORDINATE A DATE AND TIME FOR THE PRECONSTRUCTION MEETING. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. THE GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING. 15.ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCTION MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760)438-3891. INSPECTION REQUEST MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE WORKING DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 16. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 17. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 18. NO BLASTING SHALL BE PERFORMED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM THE CITY OF CARLSBAD. SUBMIT APPLICATION FOR BLASTING PERMIT WELL IN ADVANCE OF THE SCHEDULING OF BLASTING OPERATIONS. 19.IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK AREA DURING CONSTRUCTION, OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 20. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND 6:00 P.M. EACH DAY, MONDAY THRU FRIDAY AND NO EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS (A LIST OF CITY HOLIDAYS IS AVAILABLE ONLINE). 21.ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY INSPECTOR FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTE OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 22. IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 23. BRUSH SHALL BE REMOVED ONLY WITHIN THE AREA TO BE GRADED. NO TREES ARE TO BE REMOVED UNLESS SPECIFICALLY NOTED ON THE PLAN. 24. ALL AREAS SHALL BE GRADED TO DRAIN. GRADING RESULTING IN THE PONDING OF WATER IS NOT PERMITTED. ALL EARTHEN SWALES AND DITCHES SHALL HAVE A MINIMUM ONE PERCENT SLOPE. 25. THESE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SWPPP AND/OR SET OF EROSION CONTROL PLANS. EROSION CONTROL SHALL BE AS SHOWN AND AS APPROVED BY THE CITY ENGINEER OR AS DIRECTED BY THE PROJECT INSPECTOR. 26. ALL SLOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM SURFACE AND CROSS SECTION. THE SITE SHALL BE LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS OR OTHER DEBRIS SHALL BE REMOVED AND DISPOSED OF AT A SITE APPROVED OF BY THE CITY ENGINEER. 27. ALL SLOPES SHALL BE IRRIGATED, STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 28. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT, DRAWING NO. 551-9L , AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR. 29. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THESE GRADING PLANS WITH THAT SHOWN ON BOTH THE LANDSCAPE AND IRRIGATION PLANS AND THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH THE LANDSCAPE MANUAL TIME REQUIREMENTS. 30. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED AS A RESULT OF THE GRADING OPERATION, IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 31. THE EXISTENCE AND LOCATION OF UTILITY STRUCTURES AND FACILITIES SHOWN ON THE CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN. 32. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES (ABOVE GROUND AND UNDERGROUND) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF GRADING TO PERMIT THE REVISION OF THE GRADING PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. 33. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST 2 FULL WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACILITIES AND SHALL COORDINATE THE WORK WITH A COMPANY REPRESENTATIVE. UNDERGROUND SERVICE ALERT 811 OR (800)642-2444 SDG&E (800)411-7343 AT&T (800)241-3624 CHARTER/SPECTRUM CABLE (866)788-0166 COX COMMUNICATIONS (619)262-1122 CITY OF CARLSBAD(STREETS & STORM DRAIN)(442)339-2980 CITY OF CARLSBAD(SEWER,WATER & RECLAIMED WATER) (442)339-2722 34. PERMIT COMPLIANCE REQUIREMENTS: A.FOR CONTROLLED GRADING - THE APPLICANT HIRES A CIVIL ENGINEER, SOILS ENGINEER, AND/OR GEOLOGIST TO GIVE TECHNICAL ADVICE, OBSERVE AND CONTROL THE WORK IN PROGRESS {15.16.120 A.8} CARLSBAD MUNICIPAL CODE. B.PRIOR TO FINAL APPROVAL OF A GRADING PERMIT - THE FOLLOWING REPORTS MUST BE SUBMITTED TO THE CITY ENGINEER VIA THE PROJECT INSPECTOR {15.16.120 A.10} CARLSBAD MUNICIPAL CODE: 1) FINAL REPORT BY SUPERVISING GRADING ENGINEER STATING ALL GRADING IS COMPLETE. ALL EROSION CONTROL, SLOPE PLANTING AND IRRIGATION ARE INSTALLED IN CONFORMANCE WITH CITY CODE AND THE APPROVED PLANS (OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEERING DEPARTMENT). 2) AS-BUILT GRADING PLAN. 3) REPORT FROM THE SOILS ENGINEER, WHICH INCLUDES RECOMMENDED SOIL BEARING CAPACITIES, A STATEMENT AS TO THE EXPANSIVE QUALITY OF THE SOIL, AND SUMMARIES OF FIELD AND LABORATORY TESTS AND PLOTTED TEST POINTS THE REPORT SHALL ALSO INCLUDE A STATEMENT BY THE SOILS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDATIONS OUTLINED IN THE PRELIMINARY SOILS REPORT AND ANY SUPPLEMENTS THERETO. 4) REPORT WITH AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE CITY. 35. UNLESS A GRADING PERMIT FOR THIS PROJECT IS ISSUED WITHIN ONE (1) YEAR AFTER THE CITY ENGINEER'S APPROVAL, THESE PLANS MAY BE REQUIRED TO BE RESUBMITTED FOR PLANCHECK. PLANCHECK FEES WILL BE REQUIRED FOR ANY SUCH RECHECK. 36. IN ACCORDANCE WITH THE CITY STORM WATER STANDARDS, ALL STORM DRAIN INLETS CONSTRUCTED BY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTEWATER DISCHARGE DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SATISFACTION OF THE CITY ENGINEER. I (WE) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER-ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THIS SITE. I (WE) ALSO UNDERSTAND AND ACKNOWLEDGE THAT I (WE) MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPs) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND SIGNED OFF BY THE CITY OF CARLSBAD. IF THIS PROJECT/DEVELOPMENT IS SUBJECT TO A STATE-REGULATED SWPPP, I (WE) ALSO AGREE A QUALIFIED SWPPP PRACTITIONER (QSP) HAS BEEN OR WILL BE RETAINED TO SUPERVISE IMPLEMENTATION OF THE SWPPP IN ACCORDANCE WITH THE CALIFORNIA CONSTRUCTION ORDER AND MUNICIPAL PERMIT, LATEST VERSION. JOHN NORUM FOR: TIDES AT TERRAMAR LLC DATE I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. FIRM: PASCO, LARET, SUITER, AND ASSOCIATES, INC. ADDRESS: 1911 SAN DIEGO AVE., SUITE 100 CITY, ST.: SAN DIEGO, CA 92110 PHONE: (858) 259-8212 EMAIL: BKNAPP@PLSAENGINEERING.COM BY: DATE: BRYAN A. KNAPP R.C.E. NO.:86542 REG. EXP. DATE: 03/31/2027 I, JAIME A. CERROS, A REGISTERED GEOTECHNICAL STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS ENGINEER OF THE HEREBY CERTIFY THAT A SAMPLING AND STUDY OF THE SOIL CONDITIONS PREVALENT MECHANICS, SITE WAS MADE BY ME OR UNDER MY DIRECTION BETWEEN THE DATES OF WITHIN THIS MAY 8, 2024 AND JUNE 17, 2024. TWO COPIES OF THE SOILS REPORT COMPILED FROM THIS STUDY, WITH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE OF THE CITY ENGINEER. SIGNED: DATE: GEOTECHNICAL EXPLORATION INC. JOB NO. 24-14681 G.E./P.E. NO.: R.C.E. 34422 G.E. 2007 LICENSE EXP. DATE:9/30/2027 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT JOHN NORUM AT (949) 678-4927. 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS EMINENT. 3. FOR PROJECTS COVERED BY STATE SWPPP/WDID, IN ACCORDANCE WITH THE CONSTRUCTION ORDER ISSUED BY THE CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD, THE CONTRACTOR'S QUALIFIED SWPPP PRACTITIONER (QSP) SHALL UPDATE AND MAINTAIN THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) TO ADDRESS UPDATED SITE CONDITIONS OF THE PROJECT. THE UPDATED SWPPP SHALL BE KEPT AT THE PROJECT SITE AND MADE AVAILABLE TO THE CITY INSPECTOR. ADDITIONAL CONSTRUCTION BMP'S BEYOND THE ORIGINAL APPROVED SWPPP SHALL BE PROVIDED TO ADDRESS SITE CONDITIONS NOT ANTICIPATED. THE QSP SHALL REPORT BMP DEFICIENCIES TO THE CITY INSPECTOR. THE QSP SHALL OBTAIN APPROVAL FROM THE CONTRACTOR'S QUALIFIED SWPPP DEVELOPER AND THE CITY INSPECTOR REGARDING ANY SIGNIFICANT CHANGES TO BMP DEPLOYMENT. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER AND/OR CITY INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED SWPPP AND/OR EROSION CONTROL PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE THREE (3) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 10. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE EFFECTIVE COVERAGE OF GRADED SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED BY PUNCH STRAW INSTALLED IN ACCORDANCE WITH CASQA CONSTRUCTION HANDBOOK. PARTIALLY COMPLETED PROJECTS SEEKING TO INDEFINITELY STOP WORK AND CLOSE THE GRADING PERMIT MUST IMPLEMENT APPROPRIATE ACCESS RESTRICTION AND EROSION AND SEDIMENT CONTROL MEASURES TO THE SATISFACTION OF THE CITY, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1) PERMANENTLY STABILIZE ALL SLOPES (>5%) - 70% COVER WITH WELL-ESTABLISHED, SUSTAINABLE, NON-WEED VEGETATION (SEE CITY LANDSCAPE MANUAL FOR GUIDELINES) IS CONSIDERED ADEQUATE. 2) PERMANENTLY STABILIZE FLAT AREAS (≤5%) - 70% COVER WITH WELL-ESTABLISHED, SUSTAINABLE, NON-WEED VEGETATION (SEE CITY LANDSCAPE MANUAL FOR GUIDELINES) OR 2 INCHES (MINIMUM) OF PERMEABLE COVER (E.G., GRAVEL) IS CONSIDERED ADEQUATE. 3) RESTRICT ACCESS TO SITE - COORDINATE WITH CITY STAFF TO DETERMINE APPROPRIATE FENCING TYPE. 4) SIGNAGE ALONG FRONTAGE ROAD(S) POSTING THAT DUMPING, LITTERING, AND TRESPASSING ARE PROHIBITED. 5) TRESPASS ENFORCEMENT AUTHORIZATION LETTER MUST BE SENT FROM THE OWNER TO THE CITY OF CARLSBAD POLICE DEPARTMENT. 6) NOTARIZE AND RECORD AGAINST THE PROPERTY AN AGREEMENT STATING THAT OWNER IS RESPONSIBLE FOR MAINTAINING FENCING AND SIGNAGE, ADHERING TO THE FIRE PREVENTION ORDINATION, KEEPING THE SITE FREE FROM LITTER ACCUMULATION AND VEGETATION GROWTH, AND REMOVING ANY ILLEGALLY DUMPED MATERIALS AT THE SITE UNTIL THE PROPERTY IS DEVELOPED IN THE FUTURE. THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S): 210-062-09-00 THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N 351 E 1670 DWG 18-AD DWG 141-5 DWG 270-2 DWG 540-1 TOTAL LOT AREA = 6,000 SF TOTAL DISTURBED AREA = 8,425 SF (THIS AREA INCLUDES BUT IS NOT LIMITED TO OFF-SITE WORK INCLUDING PUBLIC IMPROVEMENTS AND TEMPORARY DISTURBANCE SUCH AS VEHICLE AND EQUIPMENT STAGING AREAS, CONSTRUCTION WORKER FOOT TRAFFIC, SOIL/GRAVEL PILES, UTILITY TRENCHES, BACKFILL CUTS, AND SLOPE KEYWAYS) TOTAL PROPOSED IMPERVIOUS AREA = 5,620 SF CUT: 5 CY FILL: 450 CY IMPORT: 445 CY EXPORT: 0 CY REMEDIAL: 556 CY SITE 15 SF 184 LF 10/20/2025 10/21/2025 10/14/2025 GRADING NOTES "DECLARATION OF RESPONSIBLE CHARGE" (SHEETS 1-5) SOILS ENGINEER'S CERTIFICATE OWNER'S CERTIFICATE EROSION CONTROL NOTES ABANDONMENT NOTES SHEET NOTES SOURCE OF TOPOGRAPHY BENCHMARK PL S A 11i, ... ~ PLSAENGINEERING.COM VICINITY MAP WORK TO BE DONE CITY OF OCEANSIDE HIGHWAY, _'78 - \ .. I _\ r <·~~ " -'?: ul 'c\ ~ --1 ~ NOT TO SCALE CITY OF VISTA PACIFIC OCEAN INDEX OF SHEETS REFERENCE DRAWINGS LEGAL DESCRIPTION PROJECT ADDRESS PROJECT LOCATION DEVELOPER EARTHWORK QUANTITIES DESCRIPTION ABBREVIATION LEGEND POST-CONSTRUCTION BMP TABLE STORM WATER REQUIREMENTS THAT APPLY: C><J STANDARD STORMWATER REQUIREMENTS □ PRIORITY PROJECT REQUIREMENTS EXEMPT FROM TRASH CAPTURE? cg] YES □ NO EXEMPT FROM HYDROMOD/F/CA TION? n YES cg] NO LEGEND DWG.NO. SYMBOL QUANTITY -- 64 ----64 ----··-- IXXXXXXXXXXXXXXI VZZZZZZZZZZZZZJ ii IOI IOI IOI IOI IOI IOI IOI IOI IOI Ill ¢i ij ti ti #i ij ij ti ti #i ij ij ij I .I b&SS5?2YY%72226ZA&Si ARRRRRRRRRRRRRRRRRRI • a • t----+---+------------+---+----+---+-----t~I CITY OF CARLSBAD II~ 1-----1--+----------------1----+--+----1----1 GRADING PLANS FOR: CARLSBAD BOULEVARD HOMES 1-----1--+----------------1----+--+----1----1 ::,GR=2=0=2=5=-=00=0=7===:::::Tl:::::n.E:=::::::S::::H:EE:::T:::::::======;;:;::: APPROVED: TlMOlHY 0. CARROU PRINCl'AL ENGINEER RCE 55381 EXPIRES 121"1 /26 DAlE DA lE INITIAL DA lE INITIAL DAlE INITIAL CHKD BY: __ _ PROJECT NO. DRAWING NO. ENGINEER OF WORK REVISION DESCRIPTION DlHER APPROVAL CllY APPROVAL RVWD BY: MS2024-0006 551-9A JS JS Docusign Envelope ID: A5002C08-3FBD-4304-B3F5-EBFA8A9F0454 12/23/2025 C C X X X X X X X X X X X XXXXXXXXXX X X X 55 55 55 55 55 55 55 55 50 50 50 50 50 50 50 50 5 0 45 45 45 45 45 45 45 45 45 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SDSD SD SD SD SD SD SD W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W W W W JT JT JT JT G G G G G G G G G W W W W E E E E E E E E E E E E E E E E E E E E E E E E EEEE E E E E SD W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S WM SD SD SD SD SD SD SD C SD SD SD SD SD SD SD C X X X X SD SD SD SD SD SD UNIT 2 FF = 50.5 PAD = 49.8 UNIT 1 FF = 50.5 PAD = 49.8 FF = 48.0 PAD = 47.3 FF = 48.0 PAD = 47.3 LOT 34 MAP 2696 LOT 32 MAP 2696 LOT 27 MAP 2696 LOT 29 MAP 2696 LOT 28 MAP 2696 50.2 FS (46.9 BW) (53.02) TW (51.05) BW@FS (53.50)TW (50.01) BW@FS NORTH (49.71) BW@FS SOUTH (53.15) TW (49.33) BW@FS NORTH (49.49) BW@FS SOUTH (55.15) TW (47.16) BW@FS NORTH (47.65) BW@FS SOUTH 49.6 TG 49.0 IE 49.8 FS 5. 0 % 50.3 FS 49.8 FS 50.3 FS 5. 0 % GF = 49.8 5" STEP 50.1 FS 49.7 FS 49.7 FS GF = 49.8 5. 0 % 47.6 TG 46.0 IE 49.5 FL 48.2 TW 47.6 TW@FS 47.6 BW@FS 45.5 TF; H = 2.7' 49.6 TG 49.0 IE 47.6 TG 46.4 IE 49.6 TG 48.1 IE 5" STEP 50.1 FS 50.2 TW 50.0 TW@FS (46.6) BW@FS 45.5 TF; H = 4.7' 50.1 FS50.1 FS 50.1 FS 47.8 IE 50.1 FS 47.8 IE 5. 0 % CA D 49.6 TG 48.8 IE 49.6 TG 48.8 IE 10 . 0 ' 13.0'20.0' 10 . 0 ' 13.0'20.0' 7" STEP 49.5 FS 7" STEP 48.9 FS 7" STEP 48.2 FS 7" STEP 47.6 FS 49.9 FS 50.2 TW 50.0 TW@FS (46.5) BW@FS 45.5 TF; H = 4.7' 50.3 TW 50.1 TW@FS (48.8) BW@FS 48.3 TF; H = 2.0' 50.2 TW 49.7 TW@FS (46.8) BW@FS 45.5 TF; H = 4.7' 48.2 TW 47.6 TW@FS (45.3) BW@FS 44.2 TF; H = 4.0' 47 . 5 T W 47 . 3 T W @ F S (4 4 . 0 ) B W @ F S 43 . 5 T F ; H = 4 . 0 ' 47 . 5 T W 47 . 3 T W @ F S (4 4 . 0 ) B W @ F S 43 . 5 T F ; H = 4 . 0 ' 47 . 5 T W 47 . 3 T W @ F S (4 4 . 0 ) B W @ F S 43 . 5 T F ; H = 4 . 0 ' 47 . 5 T W 47 . 3 T W @ F S (4 4 . 0 ) B W @ F S 43 . 5 T F ; H = 4 . 0 ' 7" STEP 49.5 FS 7" STEP 48.9 FS 7" STEP 48.2 FS 7" STEP 49.5 FS 7" STEP 48.9 FS 7" STEP 48.2 FS 7" STEP 47.6 FS 50.0 FL 7" STEP 47.6 FS 3 3 9 4 4 ROW ROW ROW E 7 6 6 6 8 8 5.0'5.0' 49 48 47 46 51 52 5353 52 51 5. 0 ' 15 15 15 15 15 50 5. 0 % 49.6 TG 48.1 IE 9 7 14 N30°03'20"W 74.98' N5 9 ° 5 5 ' 0 3 " E 80 . 0 0 ' N30°04'01"W 75.00' N5 9 ° 5 4 ' 0 9 " E 79 . 9 9 ' CARLSBAD BLVD (50.0 TW) (49.0 BW) 50.3 FS 50.2 FS B 12 12 50.2 TW 50.2 TW@FS 50.2 BW@FS 49.5 TF; H = 0.7'50.5 TW 50.3 TW@FS 50.3 BW@FS 49.0 TF; H = 1.5' 51.3 TW 51.1 TW@FS 50.3 BW@FS 49.3 BF; H = 2.0'50.3 FS (50.0 FS) (51.8 FS) 50.2 FS 5.0' STBK 5.0' STBK 20 . 0 ' S T B K 10 . 0 ' S T B K 6" STEP 50.1 FS 1. 5 % 1. 5 % 6" STEP 50.1 FS 3" PERFORATED PIPE 3" PERFORATED PIPE A C B D E 50.2 TG 42.4 IE IN (N) 42.2 IE OUT (E) 17 13 . 0 ' (4 7 . 2 7 ) T W (4 4 . 7 2 ) B W @ F S EX I S T I N G W O O D FE N C E T O R E M A I N 47 . 3 F S / H P 47 . 3 F S / H P 47 . 2 T G 45 . 6 I E 4" STEP 47.7 FS 4" STEP 47.7 FS 1 3 47 . 2 T G 46 . 2 I E I N ( N ) 46 . 2 I E O U T ( E ) 45 . 2 I E O U T ( S ) 9 47 . 2 T G 45 . 6 I E 347 . 3 F S / H P 16815 15 6" PERFORATED PIPE 45.2 IE45.2 IE45.2 IE45.2 IE45.2 IE45.2 IE45.2 IE 47 . 2 T G 45 . 6 I E 3 45.2 IE 47 . 2 T G 46 . 2 I E I N ( W ) 44 . 5 I E I N ( S ) 43 . 8 I E I N ( N ) 43 . 6 I E O U T ( E ) 13 EXISTING POOL 49.9 TG 42.8 IE18 (46.8 BW) EXISTING STRUCTURE EXISTING STRUCTURE EXISTING FREE STANDING MASONRY WALL CENTERED ON PROPERTY LINE TO REMAIN EXISTING WOOD FENCE TO REMAIN EXISTING STRUCTURE EXISTING STRUCTURE 5. 0 % 45.9 BF5 45.9 BF 5 (46.3 FS)47.1 BF 5 (47.1 FS) (45.2 FS) 2.0% 2.0% 1.0%1.0%1.0%1.0%1.0%1.0% 5. 0 % 5. 0 % 2222 2 19 19 2 2 2 2 2 2 45.4 BF 5 (49.7 FS) (49.5 FS) (47.0 FS) 11 11 11 10 10 10 10 10 10 10 10 10 10 1010 50.3 TW 50.1 TW@FS 50.1 BW@FS 48.8 TF; H = 1.5' 19 48 . 2 T W 47 . 6 T W @ F S (4 4 . 6 ) B W @ F S 43 . 5 T F ; H = 4 . 7 ' 2 47 . 5 T W 47 . 3 T W @ F S (4 4 . 7 ) B W @ F S 44 . 2 T F ; H = 3 . 3 ' 2 48 . 2 T W 47 . 6 T W @ F S 46 . 4 B W @ F S 44 . 8 T F ; H = 3 . 4 ' 2 (SEE DWG 551-9 FOR PUBLIC IMPROVEMENTS IN ROW) 50.5 FS 50.6 FS 50.6 FS 15 . 0 % 15 . 0 % EX. SEWER MH 53.95 RIM 43.55 FL EX. SD MH 52.57 RIM 37.07 FL EX. SD MH 54.33 RIM 38.53 FL EX. SEWER MH 52.73 RIM 46.53 FL EXISTING TRANSFORMER TO REMAIN EXISTING AT&T PEDESTAL TO REMAIN EXISTING CHARTER PEDESTAL TO REMAIN WATER SERVICE TO CORE THROUGH SLURRY ENCASEMENT EXISTING 6" VCP SEWER MAIN PER DWG 141-5 EXISTING 30" RCP STORM DRAIN PER DWG 270-2 299 LF ; S = 0.5% CMWD 12" PVC WATER MAIN PER DWG 540-1 EXISTING 6" VCP SEWER MAIN PER DWG 141-5 342 LF; S = 0.8% EXISTING 6" ACP WATER MAIN PER DWG 18-AD EXISTING SDG&E CONDUIT BANK WITH SLURRY ENCASEMENT EXISTING 4" CI WATER MAIN (ABANDONED) EXISTING 4" HP GAS PER DWG 270-2 EXISTING FIRE HYDRANT EXISTING SDG&E CONDUIT BANK WITH SLURRY ENCASEMENT EX. SEWER MH 51.83 RIM 40.93 FL EXISTING 6" ACP WATER MAIN PER DWG 18-AD 44 4 4 44 43 45 46 47 48 49 46 48 49 51 52 53 51 52 53 54 RE T . W A L L S U B D R A I N O U T L E T 43 . 8 I E 50.6 RIM (43.8 IE) PER DWG 551-9 CL 20 20 20 20 21 21 21 47.4 FS 45.9 IE PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4169 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. 6 PLAN VIEW - GRADING PLAN SCALE: 1" = 10' HORIZONTAL J:\ACTIVE JOBS\4169 KMJ CARLSBAD BLVD\CIVIL\DRAWING\GRADING PLANS\4169-CV-GP-02-GRAD.DWG CONSTRUCTION NOTES EXISTING SURVEY MONUMENT SHALL BE PROTECTED IN PLACE. MONUMENT SHALL BE REPLACED BY A LICENSED LAND SURVEYOR WHO SHALL FILE A CORNER RECORD WITH THE COUNTY IF DISTURBED OR DESTROYED PROPOSED ORCO MASONRY RETAINING WALL W/ FENCE PER DETAIL SHEET 6 PROPOSED 6" AREA DRAIN PROPOSED 8" PRO SERIES CHANNEL DRAIN BY NDS OR APPROVED EQUAL PROPOSED DEEPENED FOOTING PER ARCHITECTURAL PLANS PROPOSED STEM WALL PER ARCHITECTURAL PLANS PROPOSED VEHICULAR PERVIOUS PAVER; SEE DETAIL SHEET 3 PROPOSED PEDESTRIAN PERVIOUS PAVER; SEE DETAIL SHEET 3 PROPOSED 12"X12" BROOKS BOX GRATED INLET OR APPROVED EQUAL PROPOSED 6" PVC SCH. 40 STORM DRAIN PIPE PROPOSED PERFORATED PIPE; SIZE PER PLAN PROPOSED FLUSH CURB PER VEHICULAR PERVIOUS PAVER DETAILS SHEET 3 PROPOSED 12"X12" BROOKS BOX SOLID PLATE COVER OR APPROVED EQUAL PORTIONS OF EXISTING RETAINING WALL ENCROACHING SUBJECT PROPERTY TO BE REMOVED PROPOSED ROOF DOWNSPOUT PROPOSED SUBGRADE GRAVEL STORAGE BASIN DETENTION SYSTEM PROPOSED 24"X24" BROOKS BOX SOLID PLATE COVER OR APPROVED EQUAL PROPOSED NDS 6" ROUND SPEE-D CATCH BASIN AND RISER WITH CLEANOUT COVER, OR APPROVED EQUAL PROPOSED MASONRY RETAINING WALL PER SDRSD C-09 PROPOSED 6" THICK PCC DRIVEWAY PROPOSED 4" THICK PCC WALKWAY ADDITIONAL NOTES 1. ALL UTILITIES SHOWN HEREON PER BEST AVAILABLE RECORD INFORMATION. 2. ALL EXISTING ONSITE STRUCTURES TO BE DEMOLISHED UNLESS OTHERWISE NOTED. 3. ALL EXISTING ONSITE TREES TO BE REMOVED UNLESS OTHERWISE NOTED. 4. ALL ONSITE WATER, SEWER, AND STORM DRAIN FACILITIES TO BE PRIVATELY MAINTAINED. 5. HARDSCAPE SHALL DRAIN AWAY FROM PROPOSED STRUCTURES AT A MINIMUM OF 2.0% FOR 10 FEET, AND LANDSCAPE FOR A MINIMUM OF 5.0% IN ACCORDANCE WITH THE 2016 CALIFORNIA BUILDING CODE SECTION 1804.4. ANY DEVIATION SHALL REQUIRE RECOMMENDATION FROM PROJECT GEOTECHNICAL ENGINEER. 6. PROPOSED SEWER LATERALS TO INCLUDE BACKWATER VALVE PER CITY OF CARLSBAD ENGINEER STANDARDS VOLUME 1 CHAPTER 6.3. GRAPHIC SCALE: 1" = 10' 0 10'20'30' 2 DATE: 12/22/2025 / l I I _. . . . _ _ . . . . , I T I I I I \ I \ . -- - - - ; 7 - - _ , - - _. . , . ', I / ' ' V \ ' \ I V ,< \ I ; \ t. I '- , / I \ \ \ I I I I 1 II I /t , r - • ( ✓ ~ I ·r '! ' " _ - - _ , _ - .q ' 0 I I ,, . - _, I - - I I / I I ?J ~ , I / / /I I I I I I I / I I I ~~ ~ - a ~ r ; Ul i II ) > :; o IT 1 s: !! l 0 z 0 IT 1 1/ ) g "'O :: : I 0 z ff i :t "l l I ~ :I / ; ;i i i ~ ! -, : C ~ ~ -, : :: I i 5! ~ E§ CD CD ;1 . ;1 , ;c "' D Kl :: I i oO "' c. . t~ §~ Cl> p C :: I i 8: > - :i 1z co C'l >z p i ~ ' "'D D :: I i ~ ; i 8 0 z .. . . §I "' ~ I ~ > !: ! z ~ C'l "'D il l i -"' :: I - ;c 0 rg :i ! -< ~ p ~ :: I i 0 I I ~ ~ Ol ~ ~ ~ ~ n - e; ; ~ ~ .. - c : : : Il l ti l 0 0 l' z j c: : : ~ n &; ~ ~ ~ ti l t: , > :: r : t: , 0 □ a: : t_ : c j c: n I I I I I I I I I I / J I f ., , ,Y I / / I I / I I I I I I I I I I I I I I / I \ I \ I I I I I I I I I I I I I I I \ I I \ ) ( I I I / / I I / I I I I I I I I I I I I I I ' ' -- / ~ I . I I I 10 I I I I __ _ _ , . . I __ _ _ , . . I ' I ' I I I I I I I I I I 0 q I -- 1 . • I ' , , \ \ I \ \ \ I I I I I I I I I I I I I I I / ( I ' I ! I I I I I I \ I I I I I I I I I I I I I I I I I I I I \ \ / / \ I \ 1 I -- I I I ) /\ I I I I I \ C ~ ,-- - - l " s c - u t+ - I I ' I 1 r- - -- - t - i, -- - - - , f- t - f i l - 1 I I I • I I I , I I 1 I I -- - 1 - - - - -- + - -- + -r - - t - + i : , I ~ \ " ( I I I I ' I I I 1 \ I I I I I I I I I I I I I I I I I I \ l I I I I , I I I / I 71 CJ ) / / / I I I I I ( I \ \ \ \ / I \ \ \ \ I \ I / / / 11 1 t- t - 1 1 11 1 11 1 11 1 ,, . , I \ I \ I \ I \ 11 \ 11 1 I \ t \ I I \ I 11 I I· G (1 / I I ( \ I \ \j I I I I I ~ I I I I I I I I ( ( I I \ I I ~ I I \ I I I I I I I I I I I I I I I I \ \ \ I I I I I \ I \ I I / I I / I \ I I \ I \ __ _ _ ., . . , , ✓ f I I I I I \ \ \ ) \ I -- + ~ I I I I I I I I I I I I I /1 I I I I I I I I I I I ( ( \ I I ( \ I \ I \ I I I I \ \ I \ I I \ I \ ( \ \ \ \ \ I l I I I I I I I I I I I / I I I / I I I I I / I / / I / ,/ I I I I I I I I l \ / / I I I I / I / I I I I I I I I I I I I I I I I \ \ I I I I I I I I \ I I \ I \ \ I \ I \ I \ \ I I \ I \ I \ I I \ \ I I I I I I I I I I \ I \ I \ I I \ I I I \ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I \ I I / I ( \ \ I I I I I I I I I I I I \ \ \ I \ I \ \ I I I I I I I I I I I I I I I I I I I I I \ JS JS Docusign Envelope ID: A5002C08-3FBD-4304-B3F5-EBFA8A9F0454 12/23/2025 EXISTING GRADE 5.0%5.0% 15.0% UNIT 2 PROP. PCC DRIVEWAY PROP. 8" TRENCH DRAIN 49.6 FS 20.0' 4.0' GF = 49.8 50.2 FS PROP. VEHICULAR PERVIOUS PAVER; SEE DETAIL THIS SHEET CARLSBAD BOULEVARD (SEE DWG 551-9 FOR PROPOSED IMPROVEMENTS ) PROP. PCC DRIVEWAY PROP. FLUSH CURB PROP. FLUSH CURB REMEDIAL GRADE CUT X PL 3.0'UNIT 1 FF = 50.5 PAD = 49.8 5.0' LOT 34 MAP 2696 (46.5) FS EX. WOOD FENCE EX. STRUCTURE PROP. ORCO RETAINING WALL W/ FENCE PER DETAIL ON SHEET 6 50.2 TW 50.0 TW@FS (46.5) BW@FS 45.5 TF 50.1 FS EXISTING GRADE PROPOSED PCC WALKWAY DEEPENED FOOTING 6" PVC STORM DRAIN 6" PVC STORM DRAIN 2.0% X 49.9 FL REMEDIAL GRADE CUT 1:1 PROP. RETAINING WALL 4" PERF PIPE CHOKER COURSE - MIN. 6" THICK OF 3/8" TO 1/2" (NO.57) BASE MATERIAL BEDDING COURSE - MIN. 2" THICK OF 1/8" TO 3/8" (NO.8) SAND 6" WIDE 520-C-2500 PCC FLUSH CURB W/ DEEPENED EDGE 1.0' BELOW BOTTOM LAYER OF GRANULAR MATERIAL VOID FILLER-1/8" TO 3/8" (NO.8) AGGREGATE IN VOIDS PERVIOUS PAVERS W/ MIN. 3/8" VOID 95% COMPACTED SOIL SUBGRADE NOTE: -ALL AGGREGATE MUST BE CLEAN/WASHED AND FREE OF FINES (SAND, SILT, ETC.) -THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED -EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE -NO IMPERVIOUS LINER OF FILTER FABRIC IS TO BE USED -SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL-SUBDRAIN MAY BE REQUIRED 5% 3" PERFORATED UNDERDRAIN PIPE STORAGE LAYER - MIN. 6" THICK OF 3/4" (NO. 2) GRAVEL (40% VOID RATIO) BOTTOM OF GRAVEL LAYER TO BE FLAT 12" M A X CHOKER COURSE - MIN. 6" THICK OF 3/8" TO 1/2" (NO.57) BASE MATERIAL BUILDING DEEPENED FOOTING AND FLUSH CURB W/ DEEPENED EDGE 1.0' BELOW BOTTOM LAYER OF GRANULAR MATERIAL VOID FILLER-1/8" TO 3/8" (NO.8) AGGREGATE IN VOIDS PERVIOUS PAVERS W/ MIN. 3/8" VOID SLOPE BOTTOM OF PERVIOUS PAVER LAYER AWAY FROM BUILDING FOOTING; SEE NOTE BELOW COMPACTED SOIL SUBGRADE NOTE: -ALL AGGREGATE MUST BE CLEAN/WASHED AND FREE OF FINES (SAND, SILT, ETC.) -THE PAVERS SHALL NOT BE SEALED ONCE THE VOID FILLER HAS BEEN ADDED -EACH COURSE SHALL BE VIBRATORY COMPACTED BEFORE PLACEMENT OF NEXT COURSE -NO IMPERVIOUS LINER OR FILTER FABRIC IS TO BE USED -SPECIAL APPROVAL REQUIRED FOR USE IN HIGHLY EXPANSIVE SOIL-SUBDRAIN MAY BE REQUIRED -SLOPE SUBGRADE AWAY FROM STRUCTURES AT 5.0% MIN. FOR 10-FT MIN. 1%-5% 5%CAST-IN-PLACE 520-C-2500 PCC EDGE MIN. 4" WIDE MORTOR OR POLYMER ADHERED PAVERS TO TOP, TYP. PL X 5.0' 3.8' 3.0'2.0'UNIT 2 FF = 50.5 PAD = 49.8 5.0' LOT 32 MAP 2696 (49.5 FS) EX. FREE STANDING MASONRY WALL EX. STRUCTURE 50.1 FS EXISTING GRADE PROPOSED PCC WALKWAY (49.3 FS) 6" PVC STORM DRAIN REMEDIAL GRADE CUT 2.0% 49.7 FL X PL X 10.0' UNIT 2 FF = 48.0 PAD = 47.3 LOT 28 MAP 2696 (44.0 FS) EX. WOOD FENCE PROP. ORCO RETAINING WALL W/ FENCE PER DETAIL ON SHEET 6 47.5 TW 47.3 TW@FS (44.0) BW@FS 43.5 TF 4" STEP 47.7 FS GRAVEL DETENTION SYSTEM 6" PVC SCH40 OUTLET PIPE 12" X 12" BROOKS BOX 47.2 TG 46.2 IE IN 46.2 IE OUT 45.2 IE OUT 46.2 TOP 44.2 BOT 6" PERFORATED UNDERDRAIN PIPE PROP. PEDESTRIAN PERVIOUS PAVERS DEEPENED FOOTING 6" PVC SD OVERFLOW PIPE 12" X 12" BROOKS BOX 47.2 TG 46.2 IE IN 44.5 IE IN 43.8 IE IN 43.6 IE OUT PROP. PCC EDGE EXISTING GRADE REMEDIAL GRADE CUT 7.0' 4" RETAINING WALL PERFORATED PIPE 4" RETAINING WALL PERFORATED PIPE X PL X LOT 34 MAP 2696 PL X 0.8' LOT 32 MAP 2696 (44.0) FS EX. WOOD FENCE PROP. ORCO RETAINING WALL W/ FENCE PER DETAIL ON SHEET 6 47.5 TW 47.3 TW@FS (44.0) BW@FS 43.5 TF EXISTING GRADE (45.6 FS) EX. FREE STANDING MASONRY WALL PROP. ORCO RETAINING WALL W/ FENCE PER DETAIL ON SHEET 6 48.2 TW 47.6 TW@FS 45.6 BW@FS 44.8 TF (44.7 FS) 12"X12" BROOKS BOX GRATED INLET 47.2 TG 6" PVC OVERFLOW PIPE OUTLET 46.2 IE 44.2 BOT 46.2 TOP GRAVEL STORAGE BASIN DETENTION SYSTEM 6" AREA DRAIN 47.2 TG 45.2 IE HP 47.3 FS 44.5 IE 6" AREA DRAIN 47.2 TG 45.2 IE 46.2 TOP 45.2 IE 44.2 BOT EXISTING GRADE X 45.2 IE 6" PERFORATED UNDERDRAIN PIPE IMPERMEABLE LINER (40-MIL LDPE OR APPROVED EQUAL) ALONG THE SIDES AND BOTTOM OF THE GRAVEL STORAGE BASIN GRAVEL STORAGE BASIN DETENTION SYSTEM 6" PERFORATED UNDERDRAIN PIPE ORIFICE PLATE 6" SOLID-WALL PVC PIPE 3 LF 6" SOLID-WALL PVC PIPE 2 LF PERMEABLE GEOTEXTILE FABRIC (MIRAFI 1100N OR EQUAL) ON TOP OF GRAVEL STORAGE BASIN HP 47.3 FS NOTE: PROVIDE PERFECT SEAL BETWEEN PIPE AND LINER TRANSITION TO SOLID-WALL PVC PIPE HP 47.3 FS 6" AREA DRAIN 47.2 TG 45.2 IE INLET 45.2 IE INLET 45.2 IEINLET 45.2 IE INLET 45.2 IE 12"X12" BROOKS BOX SOLID PLATE COVER 47.2 TG 6" SOLID-WALL PVC PIPE 2 LF 6" PVC SCH 40 PIPE OUTLET PIPE 43.6 IE REMEDIAL GRADE CUT PROP. RETAINING WALL 4" PERF PIPE 43.8 IE 45.9 IE PROP. RETAINING WALL 4" PERF PIPE CL (2-3%)(2-3%) 9.8' EX. TRAVEL LANE 8.0' EX. BIKE LANE 12.0' PROP. AC PAVEMENT 12.5' EX. CENTER TURN LANE 9.8' EX. TRAVEL LANE 9.0' EX. BIKE LANE 20.4' 22.0' PROP. PCC DRIVEWAY 50.0'50.0' 8%(2-4%) ROW 2-3% 15% PL EX. 6" VCP SEWER MAIN PER DWG 141-5 EX. 6" ACP WATER MAIN PER DWG 18-AD EX. 30" RCP STORM DRAIN PER DWG 270-2 EX. 6" VCP SEWER MAIN PER DWG 270-2 EX. 6" ACP WATER MAIN PER DWG 18-AD EX. 4" HP GAS MAIN PER DWG 270-2 CMWD 12" PVC WATER MAIN PER DWG 540-1 PER DWG 551-9 *PAVEMENT SECTION TO BE VERIFIED BY PROJECT GEOTECHNICAL ENGINEER BASED ON FIELD TESTED R-VALUE PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4169 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. 6 SECTION B-B NOT TO SCALE NOT TO SCALE SECTION C-C NOT TO SCALE TYPICAL DETAIL - ORIFICE PLATE NOT TO SCALE TYPICAL DETAIL - VEHICULAR PERVIOUS PAVERS SECTION A-A NOT TO SCALE TYPICAL DETAIL - PEDESTRIAN PERVIOUS PAVERS SECTION D-D NOT TO SCALE SECTION E-E NOT TO SCALE TYPICAL SECTION - CARLSBAD BLVD NOT TO SCALE 3 DATE: 12/22/2025 I I - --~ I I -I I l L -J.v ~ ll I I I 11 ---~-----: I Ill_ I L -1=-1 1 - 11 1 IL -I I ~1"-- l lll -LlL l - ~ -t.___J -- r ••• ~;;:utr ~ 114 INCH THICK ORIFICE PIA TE. MIN SQUARE DIMENSIONS 0.5 FT GREATER THAN PIPE DIA. HOT DIP GALVANIZED PIA TE AFTER HOLES HA VE BEEN DRILLED NOTE: ATTACH TO INSIDE OF STORM DRAIN STRUCTURE IN FRONT OF SUB-DRAIN OUTLET. ATTACH WITH TAMPER PROOF BOLTS AT EACH CORNER, TYP. NOTE: ORIFICE AND FLANGE CONNECTION TO CONCRETE SHALL BE FILLED WITH 30 DUROMETER NEOPRENE RING / ('-/ ,: f / .. . I 318" DIA. HOLE(TYP.) 6"PVC UNDERDRAIN PIPE 3"LOW-FLOW ORIFICE f ,--~:-------___) ,:_ 3" (TYP.) NOTTO SCALE P L S A I■~ PLSAENGINEERING.COM 6' SOLID-WALL PVC OUTLET PIPE 12" X 12" BROOKS BOX t----+---+------------+---+----+---+-----t ~ I CITY OF CARLSBAD I I~ 1-----+--+----------------+----+----11----+-----1 GRADING PLANS FOR: CARLSBAD BOULEVARD HOMES R2025-0007 SECTIONS AND DETAILS APPROVED: 11M01HY 0. CARRO PRINCIPAL ENGINEER RCE 55381 EXPIRES 12 1 26 DAlE DA lE INITIAL DA lE INITIAL DAlE INITIAL CHKD BY: ___ PROJECT NO. DRAWING NO. ENGINEER OF WORK REVISION DESCRIPTION DlHER APPROVAL CllY APPROVAL RVWD BY: MS2024-0006 551-9A JS JS Docusign Envelope ID: A5002C08-3FBD-4304-B3F5-EBFA8A9F0454 12/23/2025 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4169 ENGINEERING DEPARTMENT 6 J:\ACTIVE JOBS\4169 KMJ CARLSBAD BLVD\CIVIL\DRAWING\GRADING PLANS\4169-CV-GP-04-SWPPP COVER.DWG 4 DESCRIPTION SYMBOL QUANTITIES CASQA Designation Construction Activity (BMP) DescriptionBest Management Practice* Erosion Control Sediment Control BMPsBMPs TrackingControl BMPs Non-Storm WaterManagement BMPs Waste Management and MaterialsPollution Control BMPs BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE GENERAL SITE MANAGEMENT REQUIREMENTS THE FOLLOWING GENERAL SITE MANAGEMENT REQUIREMENTS SHALL BE ADHERED TO THROUGHOUT THE DURATION OF THE CONSTRUCTION WORK (YEAR ROUND). 1.IN CASE EMERGENCY WORK IS REQUIRED, CONTACT:JOHN NORUM FROM TIDES AT TERRAMAR LLC AT (949) 678-4927. 2.DEVICES SHOWN ON CITY APPROVED PLANS SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE CITY INSPECTOR. 3.ALL EROSION CONTROL DEVICES SHALL BE RESTORED TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RAIN EVENT. 4.ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED DUE TO INCOMPLETE GRADING OR UNFORSEEN CIRCUMSTANCES. 5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION. 6.GRADING AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. 7.ALL BMP PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY AND WHEN THREE (3) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAIN EVENT. 8.ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. 9.ALL INACTIVE AREAS MUST BE PROTECTED WITH THE APPROPRIATE EROSION CONTROL BMPs AS DESCRIBED IN THE STORM WATER POLLUTION PREVENTION PLAN. THIS INCLUDES ALL BUILDING PADS, UNFINISHED ROADS, AND SLOPES. THE ABILITY TO INSTALL BMPs IN A PROMPT MANNER IS NOT SUFFICIENT; BMPs MUST BE INSTALLED FOR THESE AREAS. 10.PERIMETER PROTECTION AND SEDIMENT CONTROL BMPs WILL BE UPGRADED, IF NECESSARY, TO PROVIDE SUFFICIENT PROTECTION FROM RUNOFF DURING RAIN EVENTS. 11.ADEQUATE SEDIMENT CONTROL BMPs MUST BE INSTALLED AND MAINTAINED. 12.ADEQUATE BMPs TO CONTROL OFFSITE SEDIMENT TRACKING MUST BE INSTALLED AND MAINTAINED. 13.ALL CONSTRUCTION SITES ARE TO MAINTAIN EMERGENCY STOCKPILES OF BMPs ONSITE THROUGHOUT THE YEAR. BMPs MUST BE STOCKPILED AT VARIOUS LOCATIONS THROUGHOUT THE SITE FOR THE DURATION OF THE PROJECT. THE FOLLOWING INCLUDES A PARTIAL LIST OF THE QUANTITIES AND TYPES OF BMPs THAT MUST BE STOCKPILED FOR EMERGENCY DEPLOYMENT. THESE QUANTITIES ARE IN ADDITION TO THE AMOUNT OF MATERIALS THAT ARE REQUIRED TO BE INSTALLED ACCORDING TO THE SWPPP OR EROSION CONTROL PLAN: SILT FENCE 25% ROCK BAGS 125% FIBER ROLLS 50% TRACKING CONTROL 25% OTHER BMPs DETERMINED AS NEEDED 14.THE OWNER/DEVELOPER/CONTRACTOR MUST HAVE AN APPROVED SWPPP AND BE ABLE TO DEPLOY STANDBY BMPs TO PROTECT THE EXPOSED PORTIONS OF THE SITE WITHIN 48 HRS OF A PREDICTED STORM EVENT (A PREDICTED STORM EVENT IS DEFINED AS A 50% CHANCE OF RAIN WITHIN A 2-DAY NATIONAL WEATHER SERVICE FORECAST). 15.DEPLOYMENT OF PHYSICAL OR VEGETATION EROSION CONTROL BMPs MUST COMMENCE AS SOON AS SLOPES ARE COMPLETED. THE PROJECT PROPONENT MAY NOT RELY ON THE ABILITY TO DEPLOY STANDBY BMP MATERIALS TO PREVENT EROSION OF SLOPES THAT HAVE BEEN COMPLETED. 16.THE AREA THAT CAN BE CLEARED, GRADED, AND LEFT EXPOSED AT ONE TIME IS LIMITED TO THE AMOUNT OF ACREAGE THAT THE CONTRACTOR CAN ADEQUATELY PROTECT PRIOR TO A PREDICTED RAIN EVENT. FOR LARGER SITES, GRADING SHOULD BE PHASED. IT MAY BE NECESSARY TO DEPLOY EROSION AND SEDIMENT CONTROL BMPs IN AREAS THAT ARE NOT COMPLETED, BUT ARE NOT ACTIVELY BEING WORKED BEFORE ADDITIONAL GRADING IS COMPLETED. 17.ALL DISTURBED AREAS THAT ARE NOT COMPLETED AND/OR NOT BEING ACTIVELY GRADED MUST BE FULLY PROTECTED FROM EROSION IF LEFT FOR 14 OR MORE DAYS. THE ABILITY TO INSTALL BMP MATERIALS IN A PROMPT MANNER IS NOT SUFFICIENT. BMPs NEED TO BE INSTALLED IN THESE AREAS. 18.ALL TREATMENT CONTROL BMPs MUST BE INSPECTED WEEKLY AND PRIOR TO A FORECASTED RAIN EVENT OF 50% OR GREATER. IN ADDITION, TREATMENT CONTROL BMPs MUST BE INSPECTED AND/OR SERVICED PRIOR TO OCTOBER 1 OF EACH YEAR. VERIFICATION OF THESE INSPECTIONS WILL BE PROVIDED TO THE CITY UPON REQUEST. 19.IF SELECTED BMP FAILS DURING A RAIN EVENT, IT MUST BE REPAIRED OR REPLACED AS SOON AS POSSIBLE. 20.ALL CONSTRUCTION WORKERS, INCLUDING SUB-CONTRACTORS, MUST BE TRAINED ON THE IMPORTANCE OF STORM WATER POLLUTION PREVENTION AND BMP MAINTENANCE PRIOR TO COMMENCING CONSTRUCTION BETWEEN AUGUST 1 AND OCTOBER 1 OF EACH YEAR. TRAINING RECORDS MUST BE RETAINED WITHIN THE SWPPP AND AVAILABLE UPON REQUEST. 21.THE CITY RESERVES THE RIGHT TO TEMPORARILY STOP WORK ON ANY CONSTRUCTION SITE THAT MAY HAVE THE POTENTIAL TO DISCHARGE DURING A RAIN EVENT DUE TO LACK OF BMPs, PROXIMITY TO AN ENVIRONMENTALLY SENSITIVE AREA, PREVIOUS COMPLIANCE ISSUES, AMOUNT AND DURATION OF RAIN EXPECTED, AND/OR ANY OTHER STORM WATER COMPLIANCE ISSUE. EACH SITE WILL BE EVALUATED ON A CASE BY CASE BASIS TO DETERMINE IF A TEMPORARY STOP WORK IS NECESSARY. THE DEVELOPER SHALL DEPLOY STANDBY BEST MANAGEMENT PRACTICE MEASURES TO COMPLETELY PROTECT THE EXPOSED PORTIONS OF THE SITE WITHIN 48 HOURS OF A PREDICTED STORM EVENT ( A PREDICTED STORM EVENT IS DEFINED AS A FORECASTED, 40% CHANCE OF RAIN BY THE NATIONAL WEATHER SERVICE), IN ADDITION TO BMPs IMPLEMENTED YEAR-ROUND INCLUDING PERIMETER CONTROL, WIND EROSION CONTROL, TRACKING, NON-STORM WATER CONTROL, WASTE MANAGEMENT, AND MATERIALS POLLUTION CONTROL. THE NATIONAL WEATHER SERVICE FORECAST SHALL BE MONITORED AND USED BY THE DEVELOPER ON A DAILY BASIS. IF PRECIPITATION IS PREDICTED (40% CHANCE OF RAIN), THEN THE NECESSARY WATER POLLUTION CONTROL PRACTICES SHALL BE DEPLOYED WITHIN 48 HOURS AND PRIOR TO THE ONSET OF THE PRECIPITATION. THE DEPLOYMENT OF THE BMPS SHALL INCLUDE BUT NOT BE LIMITED TO GRAVEL BAGS AND SILT FENCES. A MINIMUM OF 125% OF THE MATERIAL NEEDED TO INSTALL STANDBY BEST MANAGEMENT PRACTICES MEASURES TO PROTECT THE EXPOSED AREAS FORM EROSION AND PREVENT SEDIMENT DISCHARGES MUST BE STORED ON-SITE. AREAS THAT HAVE ALREADY BEEN PROTECTED FROM EROSION USING PHYSICAL STABILIZATION OR ESTABLISHED VEGETATION STABILIZATION BMPS AS DETERMINED BY THE CITY OF CARLSBAD ARE NOT CONSIDERED TO BE "EXPOSED" FOR THE PURPOSES OF "WEATHER TRIGGERED ACTION PLAN". AN ADEQUATE SOURCE OF EQUIPMENT AND WORKERS SHALL BE AVAILABLE FOR DEPLOYMENT OF "WEATHER TRIGGERED BMPS". EROSION CONTROL HYDROSEEDING, PLANTING AND IRRIGATION 1.ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN THE CITY'S ENGINEERING STANDARDS AND LANDSCAPE MANUAL, CASQA AND THE FOLLOWING: A.SLOPES 6:1 OR STEEPER REQUIRING EROSION CONTROL MEASURES AS SPECIFIED HEREIN SHALL BE TREATED WITH ONE OF THE FOLLOWING PLANTING STANDARDS: a.STANDARD 1 - COVER CROP /AND EROSION CONTROL MATTING COVER CROP SHALL BE A SEED MIX TYPICALLY MADE UP OF QUICK GERMINATING AND FAST COVERING GRASSES, CLOVERS, AND/OR WILDFLOWERS. SUBMIT THE SPECIFIC SEED MIX FOR CITY APPROVAL PRIOR TO APPLICATION. THE COVER CROP SHALL BE APPLIED AT A RATE SUFFICIENT TO PROVIDE 90% COVERAGE WITHIN THIRTY (30) DAYS. THE TYPE OF EROSION CONTROL MATTING SHALL BE AS APPROVED BY THE CITY AND AFFIXED TO THE SLOPE AS RECOMMENDED BY THE MANUFACTURER. ON SLOPES 3 FEET OR LESS IN VERTICAL HEIGHT WHERE ADJACENT TO PUBLIC WALKS OR STREETS: WHEN PLANTING OCCURS BETWEEN AUGUST 15 AND APRIL 15, EROSION CONTROL MATTING SHALL BE REQUIRED. DURING THE REMAINDER OF THE YEAR, THE COVER CROP AND/OR EROSION CONTROL MATTING MAY BE USED. ON SLOPES GREATER THAN 3 FEET IN HEIGHT, EROSION CONTROL MATTING SHALL BE REQUIRED AND A COVER CROP SHALL NOT BE USED, UNLESS OTHERWISE APPROVED BY THE CITY. b.STANDARD 2 - GROUND COVER ONE HUNDRED (100%) PERCENT OF THE AREA SHALL BE PLANTED WITH A GROUND COVER KNOWN TO HAVE EXCELLENT SOIL BINDING CHARACTERISTICS (PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIAL AND SPACED TO PROVIDE FULL COVERAGE WITHIN ONE YEAR). c.STANDARD 3 - LOW SHRUBS LOW SPREADING WOODY SHRUBS (PLANTED FROM A MINIMUM OF 1-GALLON CONTAINERS) SHALL COVER A MINIMUM OF SEVENTY (70%) PERCENT OF THE SLOPE FACE (AT MATURE SIZE). d.STANDARD 4 - TREES AND/OR LARGE SHRUBS TREES AND/OR LARGE SHRUBS SHALL BE (PLANTED FROM A MINIMUM OF 1-GALLON CONTAINERS) INSTALLED AT A MINIMUM RATE OF ONE (1) PLANT PER TWO HUNDRED (200) SQUARE FEET. B.SLOPES 6:1 OR STEEPER AND: a.3' OR LESS IN VERTICAL HEIGHT AND ADJACENT TO PUBLIC WALKS OR STREET REQUIRE AT A MINIMUM STANDARD 1 (COVER CROP OR EROSION CONTROL MATTING). b.3' TO 8' IN VERTICAL HEIGHT REQUIRE STANDARD 1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP, 2 AND 3. c.IN EXCESS OF 8' IN VERTICAL HEIGHT REQUIRE STANDARD 1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF A COVER CROP, 2, 3, AND 4. d.REQUIRING PLANTING SHALL BE IRRATED WITH A PERMANENT, AUTOMATICALLY CONTROLLED, IRRIGATION SYSTEM COVERING 100% OF THE PLANTED AREA IN CONFORMANCE WITH THE CITY'S SLOPE IRRIGATION STANDARDS. C.AREAS GRADED FLATTER THAN 6:1 REQUIRE A COVER CROP PER STANDARD 1 WITH ONE OF MORE OF THE FOLLOWING CONDITIONS: a.SHEET GRADED PADS NOT SCHEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING. b.A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE CITY. c.IDENTIFIED BY THE CITY AS HIGHLY VISIBLE AREAS TO THE PUBLIC OR HAVE SPECIAL CONDITIONS THAT WARRANT IMMEDIATE TREATMENT. 2.ALL SLOPES SHALL HAVE IRRIGATION INSTALLED AND BE STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 3.SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROVIDE EFFICIENT COVERAGE OF GRADING SLOPES (90% COVERAGE) PRIOR TO OCTOBER 1, THE SLOPES SHALL BE STABILIZED BY AN APPROPRIATE EROSION CONTROL MATTING MATERIAL APPROVED BY THE PUBLIC WORKS INSPECTOR. 4.LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT OR AS DIRECTED BY THE CITY ENGINEER OR CITY PLANNER. 5.THE OWNER/APPLICANT SHALL ENSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THIS CONSTRUCTION SWPPP SHOWN ON ANY GRADING PLANS, LANDSCAPE AND IRRIGATION PLANS, AND IMPROVEMENT PLANS AS REQUIRED FOR THIS PROJECT WORK. 600 LF 1 EA 220 EA SE-1, SILT FENCE SE-6, GRAVEL BAG SE-7, STREET SWEEPING AND VACUUMING SE-10, STORM DRAIN INLET PROTECTION TR-1, STABILIZED CONSTRUCTION ENTRANCE NS-3, PAVING AND GRINDING OPERATIONS WM-1, MATERIAL DELIVERY AND STORAGE WM-2, MATERIAL USE WM-3, STOCKPILE MANAGEMENT WM-4, SPILL PREVENTION AND CONTROL WM-5, SOLID WASTE MANAGEMENT WM-6, HAZARDOUS WASTE MANAGEMENT WM-8, CONCRETE WASTE MANAGEMENT WM-9, SANITARY/SEPTIC WASTE MANAGEMENT EC-1, SCHEDULING WE-1, WIND EROSION NS-8, VEHICLE AND EQUIPMENT CLEANING 12/22/2025 JS JS Docusign Envelope ID: A5002C08-3FBD-4304-B3F5-EBFA8A9F0454 12/23/2025 C C X X X X X X X X X X X XXXXXXXXXX X X X X 55 55 55 55 55 55 55 55 50 50 50 50 50 50 50 50 5 0 45 45 45 45 45 45 45 45 45 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SDSD SD SD SD SD SD SD W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W W W W JT JT JT JT G G G G G G G G G W W W W E E E E E E E E E E E E E E E E E E E E E E E E EEEE E E E E SD W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S WM SD SD SD SD SD SD SD C SD SD SD SD SD SD SD C X X X X SD SD SD SD SD SD CARLSBAD BLVD 50 . 0 ' 10 0 . 0 ' R O W LOT 34 MAP 2696 LOT 32 MAP 2696 LOT 27 MAP 2696 LOT 29 MAP 2696 LOT 28 MAP 2696 UNIT 2 FF = 50.5 PAD = 49.8 UNIT 1 FF = 50.5 PAD = 49.8 EXISTING 6" VCP SEWER MAIN PER DWG 141-5 342 LF; S = 0.8% EXISTING 6" VCP SEWER MAIN PER DWG 141-5 EXISTING 30" RCP STORM DRAIN PER DWG 270-2 299 LF ; S = 0.5% EXISTING 6" ACP WATER MAIN PER DWG 18-AD EXISTING 6" ACP WATER MAIN PER DWG 18-AD EXISTING FIRE HYDRANT EXISTING 4" HP GAS PER DWG 270-2 EXISTING 4" CI WATER MAIN (ABANDONED) FF = 48.0 PAD = 47.3 FF = 48.0 PAD = 47.3 CMWD 12" PVC WATER MAIN PER DWG 540-1 EXISTING SDG&E CONDUIT BANK WITH SLURRY ENCASEMENT SE-1 SE-1 SE-1 SD-F SE-10 SD-F SE-10 SD-F SE-10SE-10 SE-10 SE-10 SE-10 SE-10SE-10 SD-K SE-10 TC-1 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4169 ENGINEERING DEPARTMENT 6 PLAN VIEW - EROSION CONTROL PLAN SCALE: 1" = 10' HORIZONTAL J:\ACTIVE JOBS\4169 KMJ CARLSBAD BLVD\CIVIL\DRAWING\GRADING PLANS\4169-CV-GP-05-SWPPP.DWG GRAPHIC SCALE: 1" = 10' 0 10'20'30' 5 DATE: 12/22/2025 ffl l PL S A PLSAENG INEERING.COM . ' 1:." ' . ,.i,. / 1>17 • , e' .. ~ ,:' '-i':r---"= • j I r:7~ J· ==~ , I II I ": L C L L - - - I I' I , SCH c_:?ilv' / __ _ f L L L I I I --~1 ~--+~----b---___J J ' C -/h--+---~. 1-._ _J - - - -j -f7 / I I r I ----- I s11==T I CIT~r OF GRADING PLANS J:CO R: >:\!FPF C---ji<U t'Y: F?C;,_IFCT r\'.~. lvl ~2~<2 4-CJ~:G H I.: =:;-. \ \\ii \I ;-; \J J '.::i:::,1-SA. JS JS Docusign Envelope ID: A5002C08-3FBD-4304-B3F5-EBFA8A9F0454 12/23/2025 S S C C X X X X X X X X X X X XXXXXXXXXX X X X 53. 9 5 R I M 43. 5 5 F L 52. 7 3 R I M 46. 5 3 F L 53. 5 9 53. 9 2 53. 2 2 53. 4 4 53. 7 7 53. 6 0 53. 8 6 52. 8 9 53. 3 4 44. 4 9 46. 3 0 44. 7 2 49. 4 9 49. 9 2 53. 5 9 53. 4 0 53. 3 3 55 55 55 55 55 55 55 55 50 50 50 50 50 50 50 50 5 0 45 45 45 45 45 45 45 45 45 G G G G G G G G G G G G G G G G G G G G G G G G G W W W W W W WM C X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 48.2 TW 47.6 TW@FS 47.6 BW@FS 45.5 TF; H = 2.7' 50.2 TW 50.0 TW@FS (46.6) BW@FS 45.5 TF; H = 4.7' 50.2 TW 50.0 TW@FS (46.5) BW@FS 45.5 TF; H = 4.7' 50.3 TW 50.1 TW@FS (48.8) BW@FS 48.3 TF; H = 2.0' 50.2 TW 49.7 TW@FS (46.8) BW@FS 45.5 TF; H = 4.7' 48.2 TW 47.6 TW@FS (45.3) BW@FS 44.2 TF; H = 4.0' 47 . 5 T W 47 . 3 T W @ F S (4 4 . 0 ) B W @ F S 43 . 5 T F ; H = 4 . 0 ' 47 . 5 T W 47 . 3 T W @ F S (4 4 . 0 ) B W @ F S 43 . 5 T F ; H = 4 . 0 ' 47 . 5 T W 47 . 3 T W @ F S (4 4 . 0 ) B W @ F S 43 . 5 T F ; H = 4 . 0 ' 47 . 5 T W 47 . 3 T W @ F S (4 4 . 0 ) B W @ F S 43 . 5 T F ; H = 4 . 0 ' 50.2 TW 50.2 TW@FS 50.2 BW@FS 49.5 TF; H = 0.7' 2222 2 2 2 2 2 2 2 48.2 TW 47.6 TW@FS (44.6) BW@FS 43.5 TF; H = 4.7' 47 . 5 T W 47 . 3 T W @ F S (4 4 . 7 ) B W @ F S 44 . 2 T F ; H = 3 . 3 ' 2 48 . 2 T W 47 . 6 T W @ F S 46 . 4 B W @ F S 44 . 8 T F ; H = 3 . 4 ' 2 UNIT 2 FF = 50.5 PAD = 49.8 UNIT 1 FF = 50.5 PAD = 49.8 FF = 48.0 PAD = 47.3 FF = 48.0 PAD = 47.3 LOT 34 MAP 2696 LOT 32 MAP 2696 LOT 27 MAP 2696 LOT 29 MAP 2696 LOT 28 MAP 2696 CARLSBAD BLVD (SEE DWG 551-9 FOR PUBLIC IMPROVEMENTS IN ROW) 2 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 PLSA 4169 REVIEWED BY: DATEINSPECTOR DATE "AS BUILT" ENGINEERING DEPARTMENT RCE EXP. 66 I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THE RETAINING WALL HEREIN, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE RETAINING WALL HEREIN AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR THE RETAINING WALL DESIGN. FIRM: ORCO BLOCK & HARDSCAPE ADDRESS: 11100 BEACH BOULEVARD CITY, ST.: STANTON, CA 90680 PHONE: (714) 527-2239 EMAIL: GABE.VERDUGO@ORCO.COM BY: DATE: GABRIEL VERDUGO R.C.E. NO.:83660 REG. EXP. DATE: 03/31/2027 PLAN VIEW - GRADING PLAN SCALE: 1" = 10' HORIZONTAL CONSTRUCTION NOTES PROPOSED ORCO MASONRY RETAINING WALL W/ FENCE PER DETAIL THIS SHEET INSPECTION NOTE: THE OWNER OR THE REGISTERED PROFESSIONAL IN RESPONSIBLE CHARGE ACTINGAS THE OWNERS AGENT SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TOPERFORM INSPECTIONS DURING CONSTRUCTION. --------' -------------........ -----------------------, __ _ ------------------ ...... __________ _ ...... ------- _____ .,.,.,. --------- ------- ,,,,.---------~ ---- -~ ,,........._ ,,,-/ / ~ I / I \ I \ / \ - ----- ' / I ' / ----...... ----- ---------- ---- --- -------------, '------------------------------- ..... ------- -----' --' --....... ______ _ ------------....... ' --- --, ( \ \ / _ ........ -................ --- ---- -----....... ---' ' ' ' .... -------------- "-.:::::: - ..._ ....... .._ ..._ 1 11 I I --- ' \ -I ', ------- • ---- ~ / ' ·1------/ ....._ ____ _ .,,,,..----/ ------------- / / / ,1• ---I I --r, . \ / / -.-- ----- ------ ---------- '=--- ----------------------- _ _J__ 1 \ \ \ \ \ \ ---- --------.... ' ' ' ' .,,,, ....... , __ ...... __ ------- ___ ,,, _,,,... ----- ~cr------ I I I I I 1· I I I \ \ \ \ \ \ \. ------ J I I -1\ \ \ ------ ----- ----' ----------- -/ -------------------------------------- I ~-~--=-=-=-=------------------ I -I' I '\ \ I I \ I I " ' ' ---- ~ ~ ~1 ~~ I~ •• .' i ·~ ~ ORCO RETAINING WALL WITH FENCE HEEL FOOTING FOR 110 MPH WIND 3 SEC GUST @ EXP C SPECIAL :INSPECTION NOTE: PROVIDE LEVEL 2 SPEGAL INSPECTION -PER TMS 602-16 TABLES 3 AND 40F THE MASONRY STEM. T.S. OR VINYL FENCE WITH POSTS@ 8' 0/C / EMBEDDED 16" MIN. INCMU. BY OTHERS. -,--,,--- NOTE: PROVIDE 'C AND V' BAR AT EACH SIDE OF CONTROL JOJNT5f ENDS OF WALLS AND@ WALL HEIGHT G-IANGES (,')iHHORZ CO/lfr.ATTOP LEVEL BACXFILL COMPA CTED TO MIN. 90% DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE= 2000 PSF. 2. EQUIVAlENT FLUID PRESSURE= 38 PCF. 3. ALLOWABLE LATERAL PASSIVE PRESSlJRE = 2m PCF. 4. GROUT STRENGTH = 2000 PSI@28 DAYS. 5. REINFORCTNG STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH, f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL HAVE STRENGTH f 'c = 2500 PSI. PORTWID CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. 3. REINFORGNG STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 B4R DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED UNO. 5. CONCRETE BLOCK SHALL BE WD IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELJ.S SHALL BE SOLID GROUTED. r RElATIVE COMPACTION PERASTM 1557-D. 7. TYPES MORTAR SHALL CONFORM TOASTMC27DANDCBC 2103. ~-, CONT.AT """"" • ~ " » ,'( 2"0-R. • ' • J"Cl.R.J' ' 3"Cl.R.--;L,f MATERIALS PER GEOTECH, 'NICAL ENGINEER /,s;;{'G._~~ 1//,' L coo= ,. -WATEJI.PRf)()f BACKSIDE OF f/ErAJN[}IG WAll JC!;'FTOF-f"G/lAVEL W!VI l'fiAAfl l'iON FI(Tfl/ FNJRl ro-. QR INSTALL J-DRA/N 2W/2 = OR APPRO\,Rl F0U0W MANUFICT!JRfR:S mi ,·~="="~ 11.:STAUATIONR«.O HMENDATl.0/'/5. -~ • s· • r " ~ ~," 'D'BAR r r--i r #4 HORZ. COi-iT. @9"0/C ll:!llE.: DIMENSIONS ARE NOT TO SCALE, I 'A, 'B, 'C' 8 'D' 2'-0" 2'-6" #4@/6" O/C 2'-8 " 2'-9" #4@/6" O/C J'-4" J'-0" #4@16" O/C 4'-0" J'-6" #4@/6" O/C 4 '-8" J'-9" #4@16" O/C 8. GROUT FOR CONCRETE BLOCK SMALL CONFORM TO ASrM C 476 AND CBC 2103. f'9 = 2000 PSI. 9. BLOCK STEM MAY BE WET•SET 1·1/2" INTO THE FOOTING WHILE THE CONCRETE JS PLASTIC BLOCK STEM M'1Y BE PLACED TO EITHER EDGE OF THE TRENCH TtPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDIS1URBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND All. REQUIRED STEEL JS TIED IN Pl.ACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN Pl.ACE AND THE BLOCK WAU. IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACTNG: 20' 0/C. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON AU ORCO WALL SYSTEM DESIGNS. ';025 0. 8-3660 0:3/31/2027 KMJ REAL ESTATE 5211 CARLSBAD BLVD. CARLSBAD, CAUFORNIA "DECLARATION OF RESPONSIBLE CHARGE" (ORCO RETAINING WALL) 11j2oj2025 t----+---+------------+---+----+---+----t~I CITY OF CARLSBAD II~ DAlE INITIAL DA lE INITIAL DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DlHER APPROVAL CITY APPROVAL GRADING PLANS FOR: CARLSBAD BOULEVARD HOMES R2025-0007 APPROVED: PRINCl'AL ENGINEER CHKD BY: __ _ RVWD BY: RETAINING WALL PLAN TlMOlHY 0. CARROLL RCE 55381 EXPIRES 12 PROJECT NO. MS2024-0006 1 26 DAlE DRAWING NO. 551-9A JS JS Docusign Envelope ID: A5002C08-3FBD-4304-B3F5-EBFA8A9F0454 12/23/2025