Loading...
HomeMy WebLinkAbout1070 SEAHORSE CT; ; CBR2025-1874; PermitBuilding Permit Finaled Residential Permit Print Date: 05/29/2026 Job Address: 1070 SEAHORSE CT, CARLSBAD, CA 92011 Permit No: Status: {city of Carlsbad CBR2025-1874 Closed -Finaled Permit Type: BLDG-Residential 2145304000 $6,000.00 Work Class: Solar/Photovoltaic Parcel#: Track#: Valuation: Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Occupant Load: Code Edition: Sprinkled: Project Title: Description: ROOF MOUNTED 6.53 KW PV SYSTEM 15 PV MODULES 1-TESLA POWERWALL 3 ESS 13.5 KWH Plan Check#: L 1-TESLA BACKUP SWITCH 1-TESLA BACKUP SWITCH 125A BACKUP SUB PANEL POWER CONTROL SYSTEM (E-REVIEW) Applicant: SOLAR OPTIMUM INC CHRIS WOLF 614 W COLORADO ST GLENDALE, CA 91204-1104 (818) 804-3122 FEE BUILDING PLAN CHECK Property Owner: SB1473 -GREEN BUILDING STATE STANDARDS FEE SOLAR-RESIDENTIAL: BATTERY BACK-UP SOLAR-RESIDENTIAL: per kW STRONG MOTION -RESIDENTIAL (SMIP) Total Fees: $854.83 Total Payments To Date: $854.83 Applied: 07/29/2025 Issued: 09/16/2025 Fina led Close Out: 11/26/2025 Final Inspection: 11/26/2025 INSPECTOR: McClane, Duncan Contractor: SOLAR OPTIMUM INC614 W COLORADO ST GLENDALE, CA 91204-1104 (818) 804-3122 Balance Due: AMOUNT $336.05 $1.00 $210.00 $307.00 $0.78 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 ti www.carlsbadca.gov Docusign Envelope ID: 62FA8060-15D6-4944-9889-645DBBE2FA13 ( City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION FOR CITY USE ONLY Plan Check No.: _____ _ PC Deposit: _____ _ B-1 Date: ____ _ This form shall be completed to initiate a residential building permit application. The building permit application is not a building permit. No work shall start until a building permit is duly issued. Job Address: 1070 Seahorse Court, Carlsbad, CA 92011 Unit#: ____ .APN: ________ _ ROOF MOUNTED 6.53 KW PV SYSTEM 115 PV MODULES I1-TESLA POWERWALL 3 ESS 13.5 KWH I1-TESLA BACKUP Description of Work:SWITCH I125A BACKUP SUB PANEL I POWER CONTROL SYSTEM Project Valuation: $ 25,000 Is there an active code enforcement violation on this site? □ Y IXI N Are Planning permits required?: □ Y R:] N Case File Nos.: _____________ _ Please indicate the type of application(s) requested and provide the applicable information: □ New SF: Living SF,-----'-' Deck SF,--------'' Patio SF,-----'-' Garage SF, ____ _,_ Is this to create a new ADU/JADU? DY □ N. New fireplace? □ Y D N. □ Remodel: ______ SF of affected area. Is the area a conversion or change of use? □ Y □ N. □ Pool/Spa: SF. Additional Gas or Electrical Features? ___________ _ fi:I Solar: 6.53 KW, 15 Modules. Mounted: ~ Roof D Ground. Tilt: DY D N. RMA: DY D N. Battery: I» Y D N. Panel Upgrade: D Y □ N. Electric Meter Number: ___________ _ □ Plumbing, Mechanical, Electrical: _______________________ _ □ Other: _______________________________ _ APPLICANT (PRIMARY CONTACT): Name: LORENA HERNANDEZ Address: 1833 S VICTORY BL VD City: GLENDALE State: CA Zip: 91201 Phone: 818-804-3122 Email: permitting@solaroptimum.com DESIGN PROFESSIONAL: Name: _____________ _ Address: ____________ _ City: ______ State: __ Zip: __ _ Phone: -------------Em a i I: _____________ _ State License: __________ _ PROPERTY OWNER: Name: Bob Kreisberg Address: 1070 Seahorse Court City: Carlsbad State: CA Zip: 92011 Phone: 949-280-0404 Email: bob@opusproductivity.com CONTRACTOR: Name: SOLAR OPTIMUM Address: 1833 S VICTORY BL VD City: GLENDALE State: CA Zip: 91201 Phone: 818-804-3122 Email: permitting@solaroptimum.com CSLB License #: 972228 Class: C 10 City Business License#: BLOS005245-04-2019 Billing Party: D Applicant □ Property Owner IXI Contractor □ Other: _____________ _ Page 1 of 4 rev 11/24 Docusign Envelope ID: 62FA8060-15D6-4944-9889-645DBBE2FA13 The construction, addition, or alteration of buildings is governed by the California Contractors License Law (commencing with Business Professions Code section 7000). The law has an exemption that allows a person who is not a California Licensed Contractor to construct a single-family residential structure and engage in home improvements and repairs, provided they meet certain requirements. (Form B-61 provides information about the requirements that apply to Owner-Builders makes you aware of your responsibilities and possible risk you may incur by having a permit issued to an Owner-Builder.) Permits for multi-family projects are only to be issued to California Licensed Contractors. Refer to Form B-16 for other frequently asked questions. APPLICANT (PROPERTY OWNER, CONTRACTOR, OR AGENT) CERTIFICATIONS: CHECK EACH BOX IB] [K] I/We certify that I/we a legal right, interest, or entitlement to the use of the property that is the subject of this application. I/We understand that State law mandates the Applicant to provide an estimated value of all work proposed (B-29 form). I/We hereby certify the construction valuation provided is accurate and includes all proposed work such as all structural work, finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, labor costs, and all permanent equipment and systems. If the valuation is underestimated, the permit may be denied, unless the Applicant can show detailed estimates to meet the approval of the Building Official. If the Applicant is not the Property Owner, both the Property Owner and Applicant (authorized Contractor or authorized Agent of the Property Owner/Contractor) must sign below. By signing this declaration, the Property Owner authorizes the Applicant listed in this application to act as the Property Owner's Agent on all matters before the city pertaining to development on this property. I/We understand that State law requires construction to be done by a Licensed Contractor and the Property Owner may apply for an Owner-Builder permit under an exemption from the law. □ A. If the Contractor is the Applicant, the License Contractor Declaration on page 4 must be completed. □ B. If the Applicant is an Owner-Builder, an Owner-Builder affidavit is required and must be submitted (Form B-61). The city will not issue a building permit until this form has been submitted. The License Contractor Declaration on page 4 does not need to be submitted. I/We have read this application form in its entirety and reviewed the building permit application and the information I/we have provided is true and correct to the best of our knowledge. Grade lines as shown on drawings accompanying this application are assumed to be correct. This certifies that the description of the project and all the plans and supporting documentation; including the location and labeling of all existing and proposed buildings, structures, access roads, and utilities and easements; are accurate in all material respects as of the date when made. I/We understand that it is my responsibility to ensure that statements and representations are not misleading. I/We agree to promptly remove, correct, or add information as needed to correct any misleading or materially inaccurate information. I/We understand that any misstatement or omission of the requested information or of any information subsequently requested might be grounds for rejecting the application, denying the application, suspending or revoking a permit issued on the basis of these or subsequent representations, or for the seeking of such other and further relief as deemed appropriate by the City of Carlsbad. If a digital submittal is made or required, I/we certify that the submittal package includes digital files that follow the city's electronic submissions standards.) Failure to submit correctly formatted electronic files may result in the submittal being returned, which will delay intake and/or review. Page 2 of 4 rev 11/24 Docusign Envelope ID: 62FA8060-15D6-4944-9889-645DBBE2FA13 IB] [R] I/We certify that I am (we are) aware of all permit requirements and will not willfully deviate from the approved plan. I/We agree to comply with all applicable city and county ordinances and state laws relating to building construction. I/We assume full responsibility for the satisfactory completion of all work authorized under the permit(s), including work performed prior to assuming control. After construction begins, I/we understand that a height certification, pad certification, or boundary certification may need to be submitted to the Building Inspector, when required. I understand that a building permit application will expire If a permit has not been issued/obtained within one year from the application date (original filing date), unless an extension of time has been granted (Form B-25). With some limited exceptions, if a building permit application expires and there is interest in proceeding with the same project, a new application will be required and the project will be subject to new fees and regulations that are in effect at the time the new application is submitted. After submitting the application, the Billing Party designated as part of the application will be sent future city invoices for above referenced building permit(s). I understand that if a permit fee or development impact fee refund is issued, the check will be mailed to the financial responsible party (the actual person or company that paid the invoice). If the information on file for the financially responsible party is outdated or inaccurate, it must be corrected before the refund can be sent. Form B-49B may be completed to update the financially responsible party's contact information. I/We agree to waive, release, and discharge the City of Carlsbad ("City") and its officers, elected or appointed officials, employees, volunteers and agents (the "Indemnified Parties") from all claims and demands, rights and causes of action of any kind with respect to the building permit application, the purpose of which is to challenge, attack set aside, void, modify, or annul the approval or denial of the application, or the processing thereof, except liability caused by the Indemnified Parties' sole negligence or willful misconduct, in which case the indemnity received by the city shall be reduced by the amount: (a) that the city's active negligence contributed to the liability on a comparative basis; or (b) such other amount as may be required by law. This obligation is effective without reference to the existence or applicability of any insurance coverages which may have been required by city or any additional insured endorsements which may extend to Indemnified Parties. Property Owner(s) and Applicant, on behalf of themselves and all parties claiming under or through them, waive all rights of subrogation and contribution against the Indemnified Parties while acting within the scope of their duties, from all claims, losses and liabilities arising out of or incident to activities or operations performed, regardless of any prior, concurrent or subsequent passive negligence by the Indemnified Parties. By signing below, I acknowledge that I have completely read, understand, and agree to the declarations above and accept 51$,(Llil~ set forth herein. (This section must be signed by both parties if not the same individual.) bth bswu-'1 Signature of Property Owner Lo-r-e,vu;v ff. e-v~ Signature of Applicant Page 3 of 4 Date: __ 7_/2_9_/_2_0_25 ____ _ Date: 07 /28/25 rev 11/24 Docusign Envelope ID: 62FA8060-15D6-4944-9889-645DBBE2FA13 CONTRACTOR CERTIFICATIONS: License Contractor Declarations CHECK EACH BOX ~ I hereby affirm under penalty of perjury that I am a licensed under provisions of Chapter 9 (commencing with section 7000) of Division 3 of the Business and Professions Code, and the license is in full force and effect. 0 WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. Place a check mark next to the declaration regarding the workers' compensation coverage that applies. Check only one (A), (B), or (C): □ A. I have and will maintain a certificate of consent to self-insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. □ B. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: □ C. I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forth with comply with those provisions. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Civil Code section 3097). If not using a construction lending agency write N/A: Lender: __________________ _ I understand that I will need a current Carlsbad business license to obtain the building permit. By signing below, I acknowledge that I have completely read, understand, and agree to the declarations above and accept all terms set forth herein. Date: 07 /28/25 Signature of Contractor FOR CITY USE ONLY Receipt Acknowledgement: ____________ _ Date: ----------BUILDING STAFF Page 4 of 4 rev 11/24 1 Permit Number Address The following document is missing from this file: This file was printed on: ______________________________________________________ ( City a · Carlsbad APPLICATION MISSING FROM PERMIT Parcel Number: Site □ □ □ [l] □ CBR2025-1874 2145304000 1070 SEAHORSE CT B-1-RESIDENTIAL PERMIT APPLICATION B-2 -COMMERCIAL PERMIT APPLICATION B-10-REROOF APPLICATION FORM B-13A-PROPERTY OWNER CONSENT FORM B-15 -PLAN CHECK REVISION APPLICATION 5/29/26 Development Services auUding Divis.ion 16.35: Far aday Av,e •VW\V .,c:arlsbad,ca.gov Building Permit Inspection History Finaled {city of Carlsbad PERMIT INSPECTION HISTORY for CBR2025-1874) Permit Type: BLDG-Residential Work Class: Solar/Photovoltaic Status: Closed -Finaled Application Date: 07/29/2025 Owner: Issue Date: 09/16/2025 Subdivision: Expiration Date: 05/26/2026 IVR Number: 65061 Address: 1070 SEAHORSE CT CARLSBAD, CA 92011 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date 11/26/2025 11/26/2025 BLDG-35 Solar Panel 302019-2025 Friday, May 29, 2026 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Checklist Item BLDG-Building Deficiency COMMENTS COMMENTS Status Passed Duncan McClane Passed Yes Yes Yes Yes Yes Passed Yes Complete Page 1 of 1 Page 1 of 9 SOLAR OP'TIMUM STRUCTURAL CALCULATIONS for SOLAR ELECTRIC SYSTEM FOR BOB KREISBERG True North Compliance Services, Inc. I PLAN REVIEW APPROVAL I THESEPI.ANSAJOCUMENTSHAVEBEEN RE\1:WEOFOR COMPI.WO:WITHTHE APPI..ICA8LECAI.IFORNIABUILDINGSTANOARDS COOES,SADCFJEOBYTliESTATEOF ~IA ANO AUENOEO BY THE JIJRISIXTION. PUN RE'AEW ACCEPTANCE OF OOCU',IENTS DOES NOT AI.ITHallZE CONSTRUCTlONTOPROCEEDINVIOLATIONOF AINFEOERH.,STATE,NORLOCALREGU.ATIOtl. BY::t",,.,,,~ DATE~ THISSET0FTifEPI.NISAN0SPECIACATI0NS lilJSTBEKEPTQIITl£);)8SfTEATAU.Tlt.lES AND ITISUHLAWFU.. TOMo\KENffCIW«lES ORAlTERATIONSWITHOUTPEAAISSIONFROM n1eqyy.OCCUPANCY0FSTRUCTURE(S)IS NOTPERMITTEDOOILANALAPPROVALIS GRANTEDBYAU.APPUCABI.EOEPARTMENTS. AT 1070 SEAHORSE CT, CARLSBAD, CA 92011, USA Solar Optimum, Inc., 614 W. Colorado St., Glendale, CA 91204 Tel: (818)745-1475 PROJECT : CLIENT : JOB NO.: INPUT DATA Exposure category (B, c or D) Importance factor, pg 77, (0.87, 1.0 or 1.15) Basic wind speed (IBC Tab 1609.3.1V35) Topographic factor (Sec.6.5.7.2, pg 26 & 45) Page 2 of9 C I = 1.00 V = 110 Kzt = PAGE : DESIGN BY : DATE : REVIEW BY: Category II mph Flat Building height to eave Building height to ridge Building length l1I he= 18 ft ~ hr= 25 ft L = 65 ft B Building width Effective area of components DESIGN SUMMARY Max horizontal force normal to building length, L, face Max horizontal force normal to building length, B, face Max total horizontal torsional load Max total u ward force ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt l<,i V2 I B = 40 ft A= 11 tt2 22.38 psf where: qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27) 21.49 kips 23.33 kips 188.16 ft-kips 70.99 ki s Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79) Kd = wind directionality factor. (Tab. 6-4, for building, page 80) = = h = mean roof height Design pressures for MWFRS P = qh [(G Cpt )-(G Cp; )] = < 60 ft, [Satisfactory) < Min (L, B), [Satisfactory] 0.91 0.85 21.50 ft where: p = pressure in appropriate zone. (Eq. 6-18, page 28). Pmin = 10 psf (Sec. 6.1.4.1 & 6.1.4.2) G Cpr = product of gust effect factor and external pressure coefficient, see table below. (Fig. 6-10, page 53 & 54) G CP; = product of gust effect factor and internal pressure coefficient.(Fig. 6-5, Enclosed Building, page 47) = 0.18 or -0.18 a= width of edge strips, Fig 6-10, note 9, page 54, MAX[ MIN(0.1B, 0.4h), 0.04B,3] = 6.00 ft Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases Roof anale 0 = 13.13 Roof anale 0 = 0.00 Roof anale 0 = 13.13 Surface Net Pressure with Net Pressure with Surface Net Pressure with GCpr (+GCp;) (-GCp;) GCpr (+GCp;) 1 0.47 6.98 15.62 0.40 5.28 2 -0.69 -20.89 -12.25 -0.69 -20.89 3 -0.43 -14.64 -5.99 -0.37 -13.21 4 -0.37 -13.11 -4.46 -0.29 -11 .29 1E 0.71 12.80 21.44 0.61 10.33 2E -1.07 -30.02 -21.37 -1 .07 -30.02 3E -0.62 -19.13 -10.49 -0.53 -17.05 4E -0.54 -17.38 -8.74 -0.43 -14.65 5 -0.45 -15.13 -6.48 -0.45 -15.13 6 -0.45 -15.13 -6.48 -0.45 -15.13 J 2 ZONE 2/3 BOUNDARY Transverse Direction Longitudinal Direction Basic Load Cases (-GCp;) GCpr (+GCp;) (-GCp;) 13.93 1T 0.47 1.74 3.91 -12.25 2T -0.69 -5.22 -3.06 -4.56 3T -0.43 -3.66 -1 .50 -2.64 4T -0.37 -3.28 -1 .12 18.97 Roof anale 0 = 0.00 -21 .37 -8.40 Surface Net Pressure with GCpr (+GCp;) (-GCp;) -6.00 1T 0.40 1.32 3.48 -6.48 2T -0.69 -5.22 -3.06 -6.48 3T -0.37 -3.30 -1 .14 4T -0.29 -2.82 -0.66 1T Transverse Direction Longitudinal Direction Torsional Load Cases BOB KREISBERG 1070 SEAHORSE CT, CARLSBAD, CA 92011 LOAD CRITERIA WEIGHT OF MODULE MODULE LENGTH MODULE WIDTH MODULE AREA UNIT WT OF MODULE AVG RACKING WT TOTAL AVG WT (MODULE+RACKING) NO OF MODULE CONNECTION POINT TRIB LENGTH CONNECTION POINT TRIB WIDTH CONN POINT TRIB. AREA LOAD PER CONN PT LOAD ROOF SLOPE SUING FORCE LOAD ON EXISTING ROOF 1) ROOFING 2) 5/8" PLYWOOD 3) ROOF RAFTER 4) INSULATION 5) MISC TOTAL DL ROOF AREA TOTAL ROOF WT WALL WT TOTAL BUILDING DL EACH MODULE AREA TOT AL AREA OF MODULE TOTAL MODULE WT ADDITIONAL DL ADDED TO EXISTING BUILDIN< LATERAL LOAD ANALYSIS COMMENTS Page 3 of9 47.6 LB 5.67 FT 3.93 FT 22.28 FT"2 2.14 PSF 0.3 PSF 2.44 PSF 15 6 FT 2.75 FT MAX. SPACING 16.5 FT"2 40 LB 20.00 DEGREE 13.75 LB LOAD*SIN(ROOF SLOPE ) 10.00 PSF 1.8 PSF 3.1 PSF 1.5 PSF 1.5 PSF 17.90 PSF 2600 SF 46.54 KIP 2.52 KIP 49.06 KIP 22.28 334.25 SF 0.92 KIP 1.87 % SINCE TOTAL ADDED DL TO THE BUILDING IS LESS THAN 10%, PER CBC 2022 EXISTING LATERAL RESISTING ELEMENTS WILL NOT BE AFFECTED VERTICAL LOAD ANALYSIS COMMENTS PER CBC SECTION 1607.13.5.1 EXCEPTION 1, THE ROOF LL NEED NOTTO BE APPLIED TO THE AREA OCCUPIED BY THE SOLAR MODULES WHERE THE CLEAR SPACE BETWEEN PANELS AND ROOF SURFACE IS 24" OR LESS. THEREFORE, DESIGN LOAD BY ADDING SOLAR MODULE OF 2.75 PSF IS LESS THAN WITHOUT MODULES AND HENCE EXISTING FRAMING WILL THEREFORE BE OK. BOB KREISBERG 1070 SEAHORSE CT, CARLSBAD, CA 92011 CONNECTION DESIGN Page 4 of9 .. Iv_E_L_o_c_1T_Y_P_R_E_s_s_u_R_E_, q __ h ______ I_22_._38_IPSF (SEE WIND LOAD CALC) A) LATERAL FORCE Fh FOR ROOFTOP STRUCTURES (FOR ONE CONN POINT) (ONE SCREW PER CONN POINT) HORIZONTAL WIND FORCE, Fh = qh *Ger* Af ASCE 7-16, Eq. 29.4.4 WIDTH OF BUILDING, B 40 FT MEAN HEIGHT OF BLDG, H 24 FT CONNECTION POINT TRIB LENGTH, I 6 FT MAX. SPACING CONNECTION POINT PROJECTED HEIGHl 0.94 FT [2.75' SIN(ROOF SLOPE)] VERTICAL PROJECTED AREA, Af 5.64 FT"2 Ger 1.9 IF(B*H*0.1>Af,1.9) ASCE 7-16, Eq. 29.4.4 WIND LATERAL FORCE, Fh 239.9 LB SLIDING FORCE 13.75 DESIGN LATERAL FORCE 253.67 B) VERTICAL FORCE Fv FOR ROOFTOP STRUCTURES ( (FOR ONE CONN POINT) VERTICAL WIND FORCE, Fv = qh * Ger* Ar ASCE 7-16, Eq. 29.4.4 WIDTH OF BUILDING, B 40 FT LENGTH OF BLDG, L 65 FT CONNECTION POINT TRIB LENGTH, I 6 FT CONNECTION POINT TRIB WIDTH, w 2.58 FT [2. 75' COS(ROOF SLOPE)] HORIZONTAL PROJECTED AREA, Ar 15.51 FT"2 Ger 1.4 IF(B*L*0.1>Ar,1.5) ASCE 7-16, Eq. 29.4.4 WIND VERTICAL FORCE, Fv 485.8 LB DESIGN WITHDRAWL FORCE 485.8 BOB KREISBERG 1070 SEAHORSE CT, CARLSBAD, CA 92011 CONNECTION DESIGN DESIGN LATERAL FORCE USE LAG SCREW CAPACITY PER ONE SCREW, 211 DESIGN CAPACITY, 211 DESIGN IS GOOD DESIGN WITHDRAWL FORCE USE LAG SCREW WITHDRAWL CAPACITY DESIGN WITHDRAWL CAPACITY DESIGN IS GOOD Page 5 of9 253.668 1/4" INCH 150 LB (NDS 2021 REFERENCE DESIGN VALUE, SEE ATTACHED) 399 LB 485.812 1/4' INCH 225 LB (NDS 2021 REFERENCE DESIGN VALUE, SEE ATTACHED) 748.125 LB COMBINED WIND SHEAR/UPLIFT 0.42 0.404 0.83 < 1.0 DESIGN IS GOOD (UPLIFT) (SHEAR) USE (2) 1/4"X3-1/2" SS LAG SCREW WITH MIN 2.5" THREAD EMBEDMENT PER CONNECTION POINT BOB KREISBERG 1070 SEAHORSE CT, CARLSBAD, CA 92011 LOAD CRITERIA WEIGHT OF BATTERY MODULE LENGTH MODULE WIDTH LOAD PER CONN PT LOAD WALL MOUNTAIN SUING FORCE Page 6 of9 BATTERY CALCULATION 287 LB 45.3 INCH 29.7 INCH 72 LB 90.00 DEGREE 71 .75 LB LOAD*SIN(ROOF SLOPE ) BOB KREISBERG 1070 SEAHORSE CT, CARLSBAD, CA 92011 CONNECTION DESIGN DESIGN LATERAL FORCE USE LAG SCREW CAPACITY PER ONE SCREW, 211 DESIGN CAPACITY, 211 DESIGN IS GOOD DESIGN WITHDRAWL FORCE USE LAG SCREW WITHDRAWL CAPACITY DESIGN WITHDRAWL CAPACITY DESIGN IS GOOD Page 7 of9 BATTERY CALCULATION 71.75 3/8 INCH 200 LB (NDS 2018 REFERENCE DESIGN VALUE, SEE ATTACHED) 266 LB 71.75 3/8 INCH 305 LB (NDS 2018 REFERENCE DESIGN VALUE, SEE ATTACHED) 1419.78 LB COMBINED WIND SHEAR/UPLIFT 0.00 0.073 0.08 < 1.0 ESIGN IS GOOD (UPLIFT) (SHEAR) USE (4) 3/8" DIA X 3-1/2" LONG 2.5" MIN THREAD EMBEDMENT LAG SCREW PER BATTERY i ,; Ii !i i 11.2 Withdrawal Design Values 11.2.1 Lag Screws 11.2.1.1 The withdrawal design values, in lbs.fin. of penetration, for a single lag screw inserted in side grain, with the lag screw axis perpendicular to the wood fibers, shall be determined from Table 11.2A or Equation 11.2-1, within the range of specific gravities and screw diameters given in Table 11.2A. Tabulated nominal design values, W, shall be multiplied by all applicable adjustment factors (see Table 10.3.1) to obtain allowable design values, W'. W=180QG312O314 (11.2-1) 11.2.1.2 When lag screws are loaded in withdrawal from end grain, nominal withdrawal design values, W, shall be multiplied by the end grain factor, Ceg = 0.75. 11 .2.1.3 When lag screws are loaded in withdrawal, the allowable tensile strength of the lag screw at the net (root) section shall not be exceeded (see 10.2.3). Table 11.2A Lag Screw Withdrawal Design Values (W)1 Tabulated withdrawal design values (W) are in pounds per inch of thread penetration into side grain ofinain member. Length of thread penetration in main member shall not include the length of the tapered tip (see Appendix L). Specific Gravity ---T n::; .:!crew Unthreaded Shank Diameter, D G 1/4" 5/16" 3/8" 7/16" 1/2" 5/8" 3/4" 7/8" l" 1-1/8" 1-1/4" 0.73 397 469 538 604 668 789 905 1016 1123 1226 1327 '.~JX'.'Wfat'.q~f:Dr')i ,:;,3f~8.JD} i ;i::~tOXti f,'.i_'$.l:Q'!W; {:'5f//Xf :'. }::641).;';; ;:At/.$1>:i ;;\8:§~:f :·.,:/9:H>/: ;AQ,t7,{J \\~l't1tb{ '." f2f1.1a?:r+: ~ 0.68 357 422 484 543 600 709 813 913 1009 1103 1193 ::,.·, .>Jrn.z;,:,.,::.,. __ , ... :l4?·:.,•·:::.~J$,:~ .. >41~.":: • .. J~r · ..... ~·~7 <:. "694~: :_19<1· ::. s9J _\ ··gs1<:-101s~<·Xt6..r:--'.-:· 0.58 281 332 381 428 473 559 641 719 795 869 940 : ·J '. , \QI~i ;i;':})./ ::\. 4QC):> :; ;:~rnot~B; ti{~'SZ :/; •• •r~Qf: .• )431' :/ • :?51,6\} /:'/592::/ \· ·<6Mf ? ,:/134(\ \/Y8Qi1?::.:. .Vi'$'~$/?l o.s1 21? ?.74 114 v,~ 390 461 528 593 656 716 775 it;yi&l \~/Q;iQ}~1f);i(\/ f?<@~lt) i 10n6~ft :\:\[~J)S,tft i ?~1it1 • ')f;$:78/? 'J~+if u,=:Jl~\}:. '/;:57Q{?, ,:i\~l41t \:/i~~s::.;;} ??t1iPi&l 0.49 218 258 296 332 367 434 498 559 617 674 730 ~:::,y;,::':·~]f:1.(1t·::cg i··;::.,~-0r~;' ;:;~'.JJt1~~i :;~:~if~,;:: ;:~~;~·rt?>: :):4$, ~, ~: : -~·M>..$::£ ::::_:~_v ;:· :': Jl_$:~.·: ,:· .'$JO:~~:. ;;:::,~~~,;er ~:,:~~,@~1:;;.~: 0.46 199 235 269 302 334 395 453 508 562 613 664 ::/:;~;':~:,:. ;;:;Q;.tm\;;t:.:~;,:; ;~;,rn:~~.;, ~;~5ao,~.;\; ~:J;~.~~-~f£ :.;,~;z~~fi$ ::.,;::~~¥4/f ~'.J$.J~;~;: ;~i~~1;~: :.;·:yrrs·~.::. ;:;~I$!.'< ~:::::sit1c.~ 1?fiZKDt:.~ 0.43 179 212 243 273 302 357 409 459 508 554 600 ;':.'.? :· .. ···:;~;~?t~>:'.:(1: '!}~'t7~"~• ':%m:$~Y \1JltS'1::t ::;~~;·"·: V'.':Z.~t ::,,, :'-H"~; ·:·:;::,~~~~t:': :~,~:,~a:,·:: ·;:'2t?.!f;'.': ,,:,:·::S).$'':,c c~'~'.$1~)'.::;~ 0.41 167 198 226 254 281 332 381 428 473 516 559 I: ':S::.-:·~:::~:~nf.Q:::;:T::,;;: ~W2t§'.L;: ;~~;,:tJt~~{~. :~&~~l~::y1 :'.:~:1~.r,! :,::';.::'grn::y:: ':7;,$i(L:~ .:.:::~~'~1~;:: ;;;j ~:rn:~r~ :·i:2I~i.;::i: '/'.'.'.!4.~'nlr:} :::.:;tl~,%¼:;'. 0.39 155 183 210 236 261 308 353 397 438 479 518 ~r:,:;;,.:;~A.t:'!)iQ).~$,y;'.;;G~:;;: ikHl~9./'. ;(,1,{(.~2~B :~;s~rr~.~~: 17,~~?1~-1% ;:,f:.~$X'.\:., ;;::::,4g9J~;; :;;:: : AfttX),;: > ,:~ ~J.A~ w::f'ic.i<}i JW;'.(4,~1-:x.: T,?*~H:.;:,xs;, 0.37 143 169 194 218 241 285 326 367 405 443 479 w:2~\;t:·::Pl:~'.HfiK.:: f.lifif$:Zi:1 :K:5(~li;BL1~ iri&t:~it:~~'. -·~:~®'ttltl ::::.tZ~J~o:% ·~.?~~:~'.{:{ ,:::][i;~;:~·.~: ;:·{??~:)'.} _{:7l$!U ;:3;;lt$.~~L: -~;zt~'.~Jt.\V:Y 0.35 132 156 179 200 222 262 300 337 373 407 441 I. Tabulated withdrawal design values (W) for lag screw connections shall be multiplied by all applicable adjustment factors (see Table 10.3.1). AMERICAN WOOD COUNCIL I I. i1· I.' I i ' ·I I en ~ Ill a:: CJ en C, C .... Table 11J LAG SCREWS: Design Values (Z) for Single Shear (two member) Connections1,2,3 I t. In. 1/2 5/8 3/4 for Sawn Lumber or SCL with both members of identical specific gravity ~ ~ cX .; G=0.55 G=0.46 g' -~ G=0.67 Mixed Maple G=0.50 G=0.49 Douglas Fir(S) ~a ~ ___ R_e_d_O_a_k _______ S_ou_th_e_m_P_in_e _____ D_o_u~gl_as_F_l_~_La_~_h ____ D_o_u~la_s_F_lr-_L_ar_c_h~N~-t----H_e_m_-_Fi~r~N~-- D in. 1/4 5/16 3/8 1/4 5/16 3/8 1/4 5/16 3/8 1/4 5/16 3/8 Zu lbs. 150 170 180 160 190 190 180 110 130 130 120 140 130 140 z,,,_,_ lbs. 110 130 130 130 140 140 140 210 150 160 210 140 160 180 140 140 230 170 170 230 160 170 110 120 120 120 130 120 130 Zu lbs. 130 150 160 140 160 170 150 140 180 130 180 140 160 160 210 160 210 ~ lbs. 90 110 110 100 110 110 110 120 120 120 140 130 z,,,_,_ lbs. 100 120 110 110 120 120 120 130 130 120 150 150 90 100 100 100 110 100 110 Zu lbs. 120 150 150 130 150 160 140 120 170 110 170 120 150 130 190 120 200 ~ lbs. 90 100 100 90 110 100 100 90 110 110 100 110 110 110 110 120 110 120 120 120 130 140 120 140 80 100 90 90 100 100 100 Z.1 lbs. 120 140 150 130 150 160 140 100 160 100 170 110 150 120 190 110 190 ~ lbs. 90 100 90 90 100 100 100 110 110 110 120 120 z,,,_,_ lbs. 90 110 110 100 110 110 110 120 120 110 140 140 80 90 90 90 100 90 90 Z.1 lbs. 110 140 140 120 150 150 130 100 160 100 160 110 150 120 180 110 180 Z..1 lbs. 80 100 90 90 100 100 90 100 100 110 120 110 z,,,_,_ lbs. 90 100 100 90 110 110 100 110 110 110 130 130 z_,_ lbs. 80 90 90 80 90 90 90 100 90 100 110 100 11/4 1/4 180 140 140 140 160 120 150 120 150 120 150 120 120 110 150 110 140 110 140 110 150 110 130 110 140 100 120 5/16 230 170 170 160 210 140 200 140 140 130 200 130 190 3/8 230 170 170 160 210 150 150 140 200 140 140 130 200 130 140 120 190 120 140 120 11/2 1/4 180 140 140 140 160 120 120 120 150 120 120 110 150 110 110 110 150 110 110 100 5/16 230 170 170 160 210 150 150 140 200 140 140 130 200 140 140 130 190 140 140 130 3/8 230 170 170 160 210 150 150 140 200 140 140 130 200 140 140 130 190 140 140 120 ,';:-,~~:~;-:;-:;!g : __ --_\m .'.·. :.~~ ~,-s~:t,:::!:\:_::,~'.''.i; >~--•·~: :;~::r~r;;:ii";1:i ~:::31~·\t~t¥·:~':?:~;,:g~ :: 3/4 950 550 660 490 830 470 560 410 770 440 510 380 760 430 510 370 730 400 480 360 7/8 1240 720 830 630 1080 560 710 540 1020 490 660 490 1010 470 650 470 970 430 610 430 1 1550 800 1010 780 1360 600 870 600 1290 530 810 530 1280 500 790 500 1230 470 760 470 1 3/4 1/4 180 140 140 140 160 120 120 120 150 120 120 110 150 110 110 110 150 110 110 100 5/16 230 170 170 160 210 150 150 140 200 140 140 130 200 140 140 130 190 140 140 130 3/8 230 170 170 160 210 150 200 140 140 130 200 140 190 140 120 ?[~i; ~;;:i1;;~;:~:H~{~:i1J~ ;~1~~iI1~~: .. :?i~l ~iiis:i:.~i ~~~~:;it:~':; 3/4 1030 580 720 520 890 480 600 430 830 450 550 390 820 440 540 380 780 420 510 360 7/8 1320 740 890 650 1150 630 750 550 1070 570 700 510 1060 550 680 490 1010 500 650 470 1630 910 1070 790 1420 700 910 670 1340 610 850 610 1320 590 830 590 1270 550 790 550 21/2 1/4 140 140 140 120 120 120 150 120 120 110 150 110 110 110 150 110 110 100 ,-..----+-----------------------------...... ------150 150 140 200 140 140 130 200 140 140 130 190 140 140 130 lio,,,,!1"'9~,■.,,tiJl!l!lf,,_..,l ......... l.!'o-~'t,-....,1'-P.'!"1150 150 ·140 200 140 140 130 200 140 140 130 190 140 140 120 :_._ -·--_.-c ,._ . _ •. ,.,}Q{t/15jiI:il~tl ~: :li:JI _ 3/4 1110 680 740 610 1010 550 650 490 960 500 610 450 950 490 600 430 920 460 580 410 7/8 1550 830 1000 740 1370 690 880 600 1280 630 830 550 1260 620 810 530 1190 580 770 500 1 1~ ~ 1~ ~ 1• • 1~ rn 1~ ~ ~ • 1~ ™ ~ ~ 1~ mm~ 3 1/2 1/4 5/16 3/8 180 230 230 140 140 140 160 120 170 170 160 210 150 170 170 160 210 150 120 120 150 150 140 200 150 140 200 120 140 140 720 850 120 110 150 110 110 140 130 200 140 140 140 130 200 140 140 1730 1. Tabulated lateral design values (Z) shall be multiplied by all applicable adjustment factors (see Table 10.3.1). 110 130 130 150 190 190 110 140 140 660 790 110 140 140 2. Tabulated lateral design values (Z) are for "reduced diameter body" lag screws (see Appendix L) inserted in side grain with screw axis perpendicular to wood fibers; minimum screw penetration, p, into the main member equal to 8D; screw bending yield strengths (F,0): F,o = 70,000 psi for D = 1/4"; FYI>= 60,000 psi for D = 5/16"; F,i, = 45,000 psi for D 2: 3/8" 3. When 4OSp<8O, tabulated lateral design values (Z) shall be multiplied by p/8D. AMERICAN WOOD COUNCIL 100 130 120