HomeMy WebLinkAboutHDP 91-23; WELDON RESIDENCE; TITLE 24 REPORT; 1990-09-13I
I
I
I
I
I
I
I
.I
I
I
I
I
I
I
Brummel, Myrick & Associates, mechanical engineering
3561 Empleo St., Suite A
San Luis Obispo, CA 93401
805 544-4269 .fax 805 544-4335
TITLE 24 REPORT.FOR:
WELDON RESIDENCE
TIERRA DEL ORO
CARLSBAD, CA
PROJECT DESIGNER:
DURAND DESIGNS
2805 THEATRE DRIVE
PASO ROBLES, CA
( 805) 2 38-0490
OWNER:
MR. & MRS. CHARLES WELDON
REPORT PREPARED BY:
BRUMMEL, MYRICK & ASSOC. --H.D. CHIN
3562 EMPLEO STREET, SUITE "A"
SAN LUIS OBISPO, CA 93401
(805) 544-4269
Job Number: 90-205
Date: 9/13/1990
~'r--
"
·~A ~E!T~ BRUMMEL \~~
'~ ~ ct~, M 17.,.@84 •
\ 91J3(&10
,:,:_ MECHArJICAL
~-r
...... ~·"-1.b ,1f'
,., !.~ .• ""
The COMPLY 24 computer program has been used to perform the calculations
summarized in this compliance report. This pro~ram has interim approval I and is authorized by the California Energy Commission for use with the
Second Generation Nonresidential Building Energ¥ Efficiency Standards
for Nonresidential Occu~ancies. Second Generation Residential Occupancies
I shown to comply with this program conform to the results produced by the
Public Domain Point System, developed by the California Energy Commission.
This program developed by Gabel Dodd Associates (415) 428-0803.
I
I
I
I Table Of Contents for Title 24 Report
I Cover Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 I Form CF-lR certificate of Compliance: Residential ................... 3
Form MF-lR Mandatory Measures Checklist: Residential ................ 6 I Form P-2R Point System summary ...................................... 8
Form WS-lR Points Thermal Mass Worksheet ............................ 9 I Form WS-2R Interpolation Worksheet .................................. 10
I Domestic Hot Water Worksheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
HVAC Zone & Space Loads Summary ..................................... 12
I
I
I
I
I
I
I
I
I
I
I
I
I CERTIFICATE OF COMPLIANCE: Residential {part 1 of 3) CF-lR page 3 of 17
I Project: WELDON RESIDENCE
Designer: DURAND DESIGNS I Location: Carlsbad Date: 9/13/1990
COMPLY 24 V 3.10
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date {User# 1704)
PROJECT ADDRESS
TIERRA DEL ORO
CARLSBAD, CA
GENERAL INFORMATION
Compliance Method:
Climate Zone:
Job#: 90-205
Point System
7
I
I
I
I
I
Total Conditioned Floor Area: 3156 sqft
Single Fam Det
East
Building Occupancy:
Front Entry Orientation:
Number of Dwelling Units:
Floor Construction Type:
Infiltration Control:
BUILDING SHELL INSULATION
Component Area
I R-13 Frame Wall
R-13 Frame Wall
R-30 Roof/Gyp Ceiling
I R-19 Roof/Gyp Ceiling
R-30 Roof/Gyp Ceiling
Exposed Slab
I
Carpeted Slab
THERMAL MASS
Mass Material
I Concrete, Heavyweight
Concrete, Heavyweight
I
I
I
I
I
I
I
198
1189
114
702
842
185
1415
Area
185
1415
1
Slab
Standard
U-Value
0.0885
0.0885
0.0355
0.0525
0.0355
0.9000
0.7200
Location/Comments
LOWER FLOOR
MAIN FLOOR
LOWER FLOOR
MAIN FLOOR
MAIN FLOOR
LOWER FLOOR/Insul= R-0.0
LOWER FLOOR/Insul= R-0.0
Thick
(in) Type Location/Description
6.000 Exposed LOWER FLOOR/Int Mass
6.000 Covered LOWER FLOOR/Int Mass
CERTIFICATE OF COMPLIANCE: Residential (part 2 of 3) CF-lR page 4 of 17 I
I
I
---------------------------------------------------------------------------COMPLY 24 V 3.10
Building Permit No
Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990 Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
I ---------------------------------------------------------------------------
GLAZING Glass w/Int
Location Orient Area Type U-Val SC Shade
I
I
I
LOWER FLOOR
West
West
MAIN FLOOR
East
East
South
South
West
North
150.0 Double
60.0 Double
36.0 Double
11.0 Single
29.0 Double
18.0 Special
291.5 Double
10.7 Double
Skylt 12.0 Double I SHADING (for Glazing above)
Location Exterior Device
0.65
0.65
0.65
1.10
0.65
0.56
0.65
0.65
0.65
I ---------------------------------LOWER FLOOR
I
I
I
I
I
I
I
I
I
I
None
None
MAIN FLOOR
None
None
None
None
None
None
None
0.88
0.88
0.88
1.00
0.88
0.65
0.88
0.88
0.88
over
SC hang
1.00 8.0
1.00 8.0
1.00 o.o
1.00 o.o
1.00 o.o
1.00 o.o
1.00 4.0
1.00 o.o
1.00 o.o
0.75
0.33
0.75
1.00
0.75
0.65
0.33
0.75
0.88
Description
Double/Nonwhite Drapes
Double/Light Blinds
Double/Nonwhite Drapes
Single/No Int Shades
Double/Nonwhite Drapes
GLASS BLOCK
Double/Light Blinds
Double/Nonwhite Drapes
Double/No Int Shades
Framing Type
Metal w/o Mullions
Metal w/o Mullions
Metal w/o Mullions
Metal w/o Mullions
Metal w/o Mullions
No Framing
Metal w/o Mullions
Metal w/o Mullions
Metal w/o Mullions
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
-I
I
CERTIFICATE OF COMPLIANCE: Residential (part 3 of 3} CF-lR page 5 of 17
Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990
COMPLY 24 V 3.10
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
HVAC SYSTEMS Minimum Output Duct Duct Manufacturer/Model No.
System Type Efficiency (Btuh) Location RVal (or approved equal) ------------------------------------------------------------------Gas Fired 0.895 SE 47000 Vent. Attic Space 2.1 LENNOX/GSR14Q3-50
No Cooling 8.900 SEER assum. Vent. Attic Space
Gas Fired 0.895 SE 47000 Vent. Attic Space 2.1 LENNOX/GSR14Q3-50
No Cooling 8.900 SEER assum. Vent. Attic Space
Max. Furnace Output:
Cooling Exception:
45000 Btuh + [(89% -71%) x 7000] = 174500 Btuh
CFM Cooling (see Load Cales) requires ___ Btuh
HOT WATER SYSTEMS
System Type
Tank Manufacturer/Model No. # of
Sys
Ener9y R-12
Credits Blanket Volume (or approved equal)
Gas Fired 76.0 GVF754T w/recirc. pump 1 0 y
SPECIAL FEATURES/REMARKS (Add extra sheets if necessary)
A DHW System utilizing pump energy has been modelled (see DHW worksheet)
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building features and performance
specifications needed to comply with Title 24, Chapter 2-53 and Title 20,
Chapter 2, Subchapter 4, Article 1 of the California Administrative Code.
This certificate has been signed by the individual with overall design
responsibility and the building owner, who shall retain a copy of it and
transmit the certificate to any subsequent purchaser of the building. When
this Certificate of compliance is submitted for a single building plan to
be built in multiple orientations, all building conservation features which
vary are indicated in the Special Features/Remarks section.
DESIGNER
DURAND DESIGNS
2805 THEATRE DRIVE
PASO ROBLES, CA
(805) 238-0490
License No:--'e,.,.::;;._c,✓,~",1,"---""'?'~JlG.~-------
S igned: ~~,1..0✓~ .-fk~/ (Irate)
DOCUMENTATION AUTHOR .
BRUMMEL, MYRICK & ASSOC. --H.D. CHIN
3562 EMPLEO STREET, SUITE "A"
SAN LUIS OBISPO, CA 934D
(805) 544:2~9
Signed:~~~L~----~ gh3/qo
(Date)
BUILDING OWNER
MR. & MRS. CHARLES WELDON
Signed: ___________ ~--:--:-
(Date)
ENFORCEMENT AGENCY
Name: ---------------Agency: _____________ _
Telephone: ____________ _
Signed: ___________ ~--=--=-
(Date)
I
I
I
I
I
I
MANDATORY MEASURES CHECKLIST (part 1 of 2)
Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN
MF-lR page 6 of 17
COMPLY 24 V 3.10
Building Permit No
Checked By
Date (User# 1704)
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the compliance approach used. Items marked
with an asterisk(*) may be superseded by more stringent compliance
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit documents, the features noted shall be
considered by all parties as binding minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
I BUILDING ENVELOPE MEASURES Enforcement
I
I
I
I
I
I
I
I
I
I
I
I
o Sec. 2-5352(a): Minimum ceiling insulation R-19
weighted average. *
o Sec. 2-5352(b): Loose fill insulation manufacturers
labeled R-Value.
o Sec. 2-5352(c): Minimum wall insulation in framed walls R-11
weighted average (does not apply to exterior mass walls). *
o Sec. 2-5352(k): Slab edge insulation -water absorption rate
no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
o Sec. 2-5311: Insulation s~ecified or installed meets
California Energy Commission (CEC) quality standards.
Indicate type and form.
o Sec. 2-5352(f): Vapor barriers mandatory in Climate Zones 14
and 16 only.
o Sec. 2-5317: Infiltration/Exfiltration Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Doors and windows certified.
c. Doors and windows weatherstripped; all joints and
penetrations caulked and sealed.
o Sec. 2-5352{e): Special infiltration barrier installed to
comply with Sec. 2-5351 meets CEC quality standards.
2-5352(d): Installation of Fireplaces
Masonry and factory-built fireplaces have:
o Sec.
1.
a. Tight fittin~, closeable metal or glass door
b. outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
MANDATORY MEASURES CHECKLIST (part 2 of 2) MF-lR page 7 of 17
Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad
COMPLY 24 V 3.10
Date: 9/13/1990
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
I HVAC AND PLUMBING SYSTEM MEASURES
o Sec. 2-5352(g) and 2-5303: Space conditioning equipment
sizing: attach calculations.
o Sec. 2-5352{h) and 2-5315: Setback thermostat on all
applicable heating systems.
o Sec. 2-5316(a): Ducts constructed, installed and insulated
per Chapter 10, 1976 UMC. *
o Sec. 2-5316(b): Exhaust systems have damper controls.
o Sec. 2-5314(c): Gas-fired space heating equipment has
intermittent ignition devices.
o Sec. 2-5314: HVAC equipment, water heaters, showerheads and
faucets certified by the CEC.
o Sec. 2-5352(1): Water heater insulation blanket {R-12 or
greater) for storage & backup tanks for solar water heating
systems; first 5 feet of pipes closest to tank insulated
(R-3 or greater).
o Sec. 2-5312(Exception I): Pipe insulation on steam and steam
condensate return & recirculating piping.
o Sec. 2-5318(d): swimming Pool Heating
1. system has:
a. On/off switch on heater.
b. Weatherproof instruction plate on heater.
c. Plumbed to allow for solar.
2. 75 percent thermal efficiency.
3. Pool cover.
4. Time clock.
5. Directional water inlet.
LIGHTING AND APPLIANCE MEASURES
o Sec. 2-5352(j): Lighting -25 lumens/watt or greater for
general lighting in kitchens and bathrooms.
o Sec. 2-5314(c): Gas fired appliances equipped with
intermittent ignition devices.
o Sec. 2-5314(a): Refrigerators, refrigerator-freezers,
freezers and fluorescent lamp ballasts certified by the CEC.
Indicate make and model number.
Enforcement
I POINTS SYSTEM SUMMARY: CLIMATE ZONE 7 P-2R page 8 of 17
I COMPLY 24 V 3.10 Project: WELDON RESIDENCE
Designer: DURAND DESIGNS I Location: Carlsbad Date: 9/13/1990
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
I
I
I
I
I
I
BUILDING DATA
conditioned Floor Area
occupancy Type
3156 sqft
Single Fam Det
SCORE CARD
1. Roof Insulation
2. Wall Insulation
3. Raised Floor Insulation
3a. controlled Vent Crawlspace
4. Slab Edge Insulation
5.
6.
Infiltration
Measure
0.0427
0.0885
0.0000
o.o
0.7777
Standard
0.66
Number of stories 2
(U-Value)
(U-Value)
(U-Value)
(R-Value) ->
(f2 factor)_
19.6%
Points
0
1
0
0
0
I 7.
Glass Heat Loss
Shade Open Area % Glass SC
X 0.77
Sum 1-6
OH Eff %
I
I
I
I
I
I
I
I
I
a. North
b. East
c. south
d. west
e. Skylight
10.7
47.0
47.0
501.5
12.0
8. Shade Closed Area
a. North
b. East
c. South
d. West
e. Skylight
10.7
47.0
47.0
501.5
12.0
0.3
1. 5
1.5
15.9
0.4
% Glass
0.3
1.5
1.5
15.9
0.4
9. Interior Thermal Mass
10. Exterior Wall Mass
X 0.80 X
X 0.73 X
X 0.77 X
X 0.77
X
X
X
X
X
SC
0.66
0.71
0.66
0.40
0.77
1.15
o.oo
X
X
X
=
1.00 =
1.00 =
0.84 = =
OH
=
1.00 =
1.00 =
0.64 =
=
11. Heating system 0.895 SE x o.78 Duct Eff =
Zonal Control: No
12. Cooling System. 8.900 SEER x 0.74 Duct Eff =
13. Water Heating (see DHW Worksheet)
0.3
1.2
1.1
10.3
0.3
Eff %
0.2
1.1
1.0
4.1
0.3
0
1
2
-5
0
3
3
4
-2
-1
-1
0
Sum 7-10
0.70 Eff SE
6.59 Eff SEER
=
Point Total:
1
4
1
0
-6
0
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
THERMAL MASS WORKSHEET
Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN
INTERIOR THERMAL MASS
Sides Wall Mass
Mass Material Thick Exposed U-Value Area -----------------------------------------------
Concrete, Heavyweight 6.00 1 185.0
Concrete, Heavyweight 6.00 0 1415.0
WS-lR page 9 of 17
COMPLY 24 V 3.10
Building Permit No
checked By
Date (User# 1704)
Interior
Mass
Factor --------
X 5.1 =
X 1.9 =
TOTAL
Interior
Mass
Capacity
943.5
2688.5
3632.0
INTERIOR MASS FACTOR 3632.0 IMC / 3156 sqft = 1.15
* Mass listed above with a Wall U-Value denotes the Interior Mass credit
for Exterior Mass Walls, and are repeated below for Exterior Mass credit.
O Sides Exposed indicates mass covered with surface material>= R-2.
EXTERIOR MASS WALLS
Mass Material
NONE
Sides Wall
Thick Exposed U-Value
Mass
Area
Exterior
Mass
Factor
Exterior
Mass
Capacity
I
I
.I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
INTERPOLATION, WEIGHTED AVERAGE & ADDITION WORKSHEET WS-2R page 10 of 17 ---------------------------------------------------------------------------Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990
COMPLY 24 V 3.10
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
INTERPOLATION
Point
Score Actual
Value Item 1
Roof
Wall
Slab Edge
Glass Type 1
Glass Type 2
Glass Type 3
N Shade Open
E Shade Open s Shade Open
W Shade Open
H Shade Open
N Shade Clsd
E Shade Clsd
S Shade Clsd
W Shade Clsd
H Shade Clsd
Int Mass
Heating
Cooling
0 +( 0.0427
1 +( 0.0885
0 + ( 0. 7777
-2 +(19.5870
0 +(19.5870
0 +(19.5870
0 +( 0.2617
1 +( 1.1901
2 +( 1.0823
-5 +(10.3267
0 +( 0.2944
3 +( 0.2231
3 +( 1.0596
5 +( 0.9772
-2 +( 4.0794
0 +( 0.2944
-1 + ( 1. 1508
0 +( 0.6981
-2 +( 6.5860
WEIGHTED AVERAGE POINTS
Value
1 ------0.04)
0.08) -0.70)
-19.00)
-19.00)
-19.00) -0.00) -1.00) -1.00)
-10.00) -0.00) -0.00)
1.00)
0.00)
4. 00) -0.00)
1.10)
0.60)
6.00)
Point Point
Score Score Value
2 1 2 ---------------
X ( -2 -0) /( 0.06
X ( 0 1) /( 0.10
X ( 0 -0) /( 0.80
X ( -2 -2) /(20.00
X ( 0 -0) /(20.00
X ( 0 -0) /(20.00
X ( 0 -0) /( 1.00
X ( 1 -1) /( 2.00
X ( 1 -2) /{ 2.00
X ( -6 --5) /(11.00
X ( -1 -0) /( 1.00
X ( 2 -3) /( 1.00
X ( 2 -3) /( 2.00
X ( 4 5) /{ 1.00
X ( -5 --2) /{ 5.00
X ( -3 -0) /( 1.00
X ( 0 --1) /{ 1.30
X ( 1 -0) /( 0.70
X ( 0 -2) /( 6.60
Type 2 Type 3
Item
Type 1
Points Area Points Area Points Area ---------
Value Point
1 Score -----------0.04) = -0 -0.08) = 1 -0.70) = 0
-19.00) = -2
-19. 00) = 0
-19.00) = 0 -0.00) = 0 -1.00) = 1 -1.00) = 2
-10.00) = -5 -0.00) = -0 -0.00) = 3 -1.00) = 3 -0.00) = 4 -4. 00) = -2 -0.00) = -1 -1.10) = -1 -0.60) = 1 -6. 00) = -o
Total Average
Area Points
Glass Type 1,2&3( -2.0 X 11 + 0.0 X 589 + 0.0 X 18) / 618 = -0
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
DHW WORKSHEET ONE: STORAGE TYPE GAS OR ELECTRIC page 11 of 17
Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990
COMPLY 24 V 3.10
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
A EQUIPMENT DATA
1 Water heater type
2 Manufacturer &
3 Model number
4 Ignition device
5 Tank volume
6 Recovery efficiency
7 Standby loss
8 Rated input
9 Number of Heaters
10 Insulation Jacket
B OPERATING DATA
1 Climate Zone
2 Water heating budget
3 Tank set temp.
4 Water main temp.
5 Daily hot water load
6 Ambient air temp.
7 Adj Standby Losses
8 No. dwelling units
9 Number of pumps
10 Pumping energy
SG
GP
76.0
76.0
3.1
57500
1 y
7
19400
140
70.0
50
62.9
0.0167
1
1
744600.0
Enter SG or SE
GVF754T w/recirc. pump
GP, gas pilot or IID, int. ignition device
Total gallons, from CEC Appliance Directory
Percent from CEC Appliance Directory
Percent/hour, from CEC Appliance Directory
Btu/hr, from CEC Appliance Directory
(1 kWh= 3413 Btu)
From building plans (total)
(Y/N) R-12 insulating jacket on the plans
See Appendix D
KBtu/yr/unit, see Table 1
F, fixed input
F, see Table 1
50 or 35 gallons/unit, see Table 1
F, see Table 1
See Table 2 or Appendix B
From building plans (total)
From building plans
Watt-hr/yr per Pump, see Table 3
C WATER HEATING ENERGY CREDITS
1 Credit name See Table 5
2 Annual savings o.o KBtu/yr/dwelling unit, see Table 5
D CALCULATE ANNUAL WATER HEATING ENERGY (KBtu/yr)
1 Recovery load
2 Recovery energy
10539.4 {[B5 X 8.25 X(140-B4)X 365 X 0.001J-C2}X B8
13867.6 Dl / A6
3
4
5
6
7
Standby loss energy 6893.8
Pumping energy 7624.0
Total energy 28385.3
Water heating budget
comparison -8985.3
Water heating budget -5.7
{24 -[(D2 X 1000)/(A8 X A9 X 365)]} X 8.25
X A5 X B7 X 365 X (140-B6) X 0.001 X A9
B9 X Bl0 X 3.413 X 3 X 0.001
GAS SYSTEMS: (D2 + D3 + D4) / B8
ELECTRIC: {[(D2 + D3) X 3] + D4} / B8
KBtu/yr/unit B2 -D5
Points (D6 / Floor Area) x 2 x B8
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
·I
I
I
I
HVAC ZONE HEATING & COOLING LOAD SUMMARY
Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990
page 12 of 17
COMPLY 24 V 3.10
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
HVAC ZONE DESCRIPTION
HVAC Zone Name:
Heating System Name:
Cooling system Name:
System Multiplier:
Heating Schedule:
Cooling Schedule:
Fan Schedule:
Peak Load Method:
Relative Humidity:
SPACES IN THIS ZONE PEAK
LOWER FLOOR (Jan 12am)
TOTAL SPACE LOAD
Bypass Ventilation Air (
Supply Duct Conduction
Supply Duct Leakage
Supply Fan Heat Gain
o cfm)
EFFECTIVE SPACE LOAD
Ventilation (
Return Air Lighting Gain
Return Duct Conduction
Return Duct Leakage
Return Fan Heat Gain
o cfm)
TOTAL SYSTEM LOAD
SYSTEM PERFORMANCE
AT DESIGN CONDITIONS
HEATING
17190
17190
-o
860
344 -o
18393
-o
920
368
-1285
18396
47000
HVAC -LOWER FLOOR
LENNOX/GSR14Q3-50
1
Residential Heating
Residential Cooling
Residential HVAC & Fans
COINCIDENT
50 %
COOLING
PEAK SENSIBLE LATENT
(Aug 2pm) 7429 5089
7429 5089
( 0 cfm) 0 0
371
149 102
0 --------------
7949 5191
( 0 cfm) 0 0
0
397
159 104
1285 --------------
9790 5295
0.8 tons 0.4 tons
0 0 o.o tons o.o tons
I
I
RESIDENTIAL SPACE HEATING LOAD SUMMARY page 13 of 17
COMPLY 24 V 3.10 Project: WELDON RESIDENCE
Designer: DURAND DESIGNS I Location: Carlsbad Date: 9/13/1990
Building Permit No
Checked By
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
-I
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
Space Name:
Design Indoor Dr¥ Bulb Temperature:
Design Outdoor Winter Dry Bulb Temperature:
Design Temperature Difference:
Conduction Area -----------------------------
R-13 Frame Wall 198.0
Double/Nonwhite Drapes 150.0
Double/Light Blinds 60.0
R-30 Roof/Gyp Ceiling 114.0
Exposed Slab Perim = 55.0
Carpeted Slab Perim = 116.5
Infiltration: 1.00 X 0.018 X 1600 sqft X 8.0
X
X
X
X
X
X
ft
LOWER FLOOR
70 F
38 F
32 F
U-Value TD -------0.0885 X 32.0 =
0.6500 X 32.0 =
0.6500 X 32.0 =
0.0355 X 32.0 =
39 =
39 =
X 0.75 ACX 32.0 =
Btu/hr ------
561
3120
1248
130
2118
4485
5530 ------
TOTAL HOURLY HEAT LOSS FOR SPACE 17190
SUPPLY AIR QUANTITY
Heating: 17190 Btu/hr/ [1.10 * (105 F Supply -0 F TStat)J = 149 cfm
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
RESIDENTIAL SPACE COOLING LOAD SUMMARY
Project: WELDON RESIDENCE
page 14 of 17
COMPLY 24 V 3.10
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
Space Name:
Design Indoor Dry Bulb Temperature:
Design outdoor Summer Dry Bulb Temperature:
Design Temperature Difference:
Conduction -----------------------R-13 Frame Wall
Double/Nonwhite Drapes
Double/Light Blinds
R-30 Roof/Gyp Ceiling
Infiltration: 1.00 X 0.018 X 1600
Solar Gain Orient.
Area ------198.0
150.0
60.0
114.0
sqft X 8.0
Shaded
Area SGF
X
X
X
X
ft
LOWER FLOOR
78 F
83 F
5 F
U-Value -------
0.0877
0.6179
0.6179
0.0347
X 0.75 AC
Unshaded
Area SGF
DETD
X 10.6 =
X 5.0 =
X 5.0 =
X 31.0 =
X 5.0 =
SC
Double/Nonwhite Drapes West
Double/Light Blinds West
( 132.1 X 15 +
( 60.0 X 15 +
17.9 X 73] X 0.66
0.0 X 73] X 0.29
=
=
Internal Gain -----------------------Lighting
Equipment
occupants
Latent Gain
Equipment
Occupants
SUPPLY AIR QUANTITY
Op Frac. Area Heat Gain -----------------------1.00 X 1600.0 X 0.200 X
1.00 X 1600.0 X 0.250 X
1.00 X 1600.0 X 225 I
TOTAL HOURLY SENSIBLE HEAT GAIN FOR
Op Frac. Area Heat Gain -----------------------1.00 X 1600.0 X 0.800 X
1.00 X 1600.0 X 225 I
TOTAL HOURLY LATENT HEAT GAIN FOR
Conv. -----
3.413 =
3.413 =
500 =
SPACE
Conv. -----
3.413 =
500 =
SPACE
Btu/hr ------
184
463
185
123
864
Btu/hr ------
2171
261
Btu/hr ------
1092
1365
720 ------
7429
Btu/hr ------
4369
720 ------
5089
Cooling: 7429 Btu/hr/ [1.08 * ( 78 F TStat -55 F Supply))= 299 cfm
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
HVAC ZONE HEATING & COOLING LOAD SUMMARY page 15 of 17
COMPLY 24 V 3.10 Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704}
HVAC ZONE DESCRIPTION
HVAC Zone Name:
Heating System Name:
cooling system Name:
System Multiplier:
Heating Schedule:
Cooling Schedule:
Fan Schedule:
Peak Load Method:
Relative Humidity:
SPACES IN THIS ZONE PEAK
MAIN FLOOR (Jan 12am}
TOTAL SPACE LOAD
Bypass Ventilation Air (
Supply Duct Conduction
Supply Duct Leakage
Supply Fan Heat Gain
o cfm)
EFFECTIVE SPACE LOAD
Ventilation (
Return Air Lighting Gain
Return Duct Conduction
Return Duct Leakage
Return Fan Heat Gain
O cfm)
TOTAL SYSTEM LOAD
SYSTEM PERFORMANCE
AT DESIGN CONDITIONS
HEATING
19338
19338
-o
967
387 -o
20692
-o
1035
414
-1285
20855
47000
HVAC -MAIN FLOOR
LENNOX/GSR14Q3-50
1
Residential Heating
Residential Cooling
Residential HVAC & Fans
COINCIDENT
50 %
COOLING
PEAK SENSIBLE LATENT
(Aug 2pm} 17404 4949
17404 4949
( 0 cfm} 0 0
870
348 99
0 --------------
18622 5048
( 0 cfm) 0 0
0
931
372 101
1285 --------------
21210 5149
1.8 tons 0.4 tons
0 0
0.0 tons o.o tons
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
RESIDENTIAL SPACE HEATING LOAD SUMMARY
Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
page 16 of 17
COMPLY 24 V 3.10
Location: Carlsbad Date: 9/13/1990
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
Space Name:
Design Indoor Dr¥ Bulb Temperature:
Design outdoor Winter Dry Bulb Temperature:
Design Temperature Difference:
conduction Area -----------------------------
R-13 Frame Wall 1189.3
Double/Nonwhite Drapes 75.7
Single/No Int Shades 11.0
GLASS BLOCK 18.0
Double/Light Blinds 291.5
R-19 Roof/Gyp Ceiling 702.0
R-30 Roof/Gyp Ceiling 842.0
Double/No Int Shades 12.0
Infiltration: 1.00 X 0.018 X 1556 sqft X 9.0
X
X
X
X
X
X
X
X
ft X
U-Value -------
0.0885
0.6500
1.1000
0.5650
0.6500
0.0525
0.0355
0.6500
MAIN FLOOR
70 F
38 F
32 F
TD
X 32.0 =
X 32.0 =
X 32.0 =
X 32.0 =
X 32.0 =
X 32.0 =
X 32.0 =
X 32.0 =
0.75 ACX 32.0 =
Btu/hr ------
3367
1574
387
325
6063
1180
957
250
6050 ------
TOTAL HOURLY HEAT LOSS FOR SPACE 19338
SUPPLY AIR QUANTITY
Heating: 19338 Btu/hr/ [1.10 * (105 F Supply -0 F TStat)] = 167 cfm
I RESIDENTIAL SPACE COOLING LOAD SUMMARY page 17 of 17
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Project: WELDON RESIDENCE
Designer: DURAND DESIGNS
Location: Carlsbad Date: 9/13/1990
COMPLY 24 V 3.10
Building Permit No
Checked By
Documentation: BRUMMEL, MYRICK & ASSOC. --H.D. CHIN Date (User# 1704)
Space Name:
Design Indoor Dry Bulb Temperature:
Design outdoor Summer Dry Bulb Temperature:
Design Temperature Difference:
MAIN FLOOR
78 F
83 F
5 F
Conduction -----------------------R-13 Frame Wall
Double/Nonwhite Drapes
Single/No Int Shades
GLASS BLOCK
Double/Light Blinds
R-19 Roof/Gyp Ceiling
R-30 Roof/Gyp Ceiling
Double/No Int Shades
Infiltration: 1.00 X 0.018 X 1556
Solar Gain Orient. --------------------------------Double/Nonwhite Drapes East [
Single/No Int Shades East [
Double/Nonwhite Drapes South [
GLASS BLOCK South [
Double/Light Blinds West [
Double/Nonwhite Drapes North [
Double/No Int Shades Skylight [
Internal Gain Op Frac. -------------------------------
Lighting 1.00
Equipment 1.00
Occupants 1.00
TOTAL HOURLY
Latent Gain Op Frac. -------------------------------
Equipment 1.00
Occupants 1.00
Area U-Value DETD Btu/hr -------------------
1189.3 X 0.0877 X 10.6 = 1105
75.7 X 0.6179 X 5.0 = 234
11. 0 X 1.0110 X 5.0 = 56
18.0 X 0.5405 X 5.0 = 49
291. 5 X 0.6179 X 5.0 = 901
702.0 X 0.0507 X 31.0 = 1104
842.0 X 0.0347 X 31. 0 = 905
12.0 X 0.6179 X 5.0 = 37
sqft X 9.0 ft X 0.75 ACX 5.0 = 945
Shaded Unshaded
Area SGF Area SGF SC Btu/hr ------o.o X 15 + 36.0 X 73] X 0.66 = 1734 o.o X 15 + 11. 0 X 73] X 0.88 = 707
0.0 X 15 + 29.0 X 32] X 0.66 = 612
0.0 X 15 + 18.0 X 32] X 0.65 = 374
111.6 X 15 + 179.9 X 73] X 0.29 = 4301 o.o X 15 + 10.7 X 15] X 0.66 = 106
0.0 X 15 + 12.0 Xl52] X 0.77 = 1413
Area Heat Gain Conv. Btu/hr --------------------------
X 1556.0 X 0.200 X 3.413 = 1062
X 1556.0 X 0.250 X 3.413 = 1328
X 1556.0 X 225 I 500 = 700 ------
SENSIBLE HEAT GAIN FOR SPACE 17404
Area ------
X 1556.0 X
X 1556.0 X
Heat Gain ---------0.800 X
225 I
Conv. -----
3.413
500
Btu/hr
= 4249 = 700
TOTAL HOURLY LATENT HEAT GAIN FOR SPACE 4949
I ~~::~:-~=~-~~~::::
Cooling: 17404 Btu/hr/ [1.08 * ( 78 F TStat -55 F Supply)] = 701 cfm
I
I