Loading...
HomeMy WebLinkAboutDWG 540-9; 3840-23; Poinsettia Lift Station Generator Replacement; 01-21AVECOSTALA BL V D CA R L S B A D RD ALGA PALOMAR AIRPOR T RD EL CAMIN O RE A L RAN C H O SAN T A F E RD POINS E T T I A LANE ALI C A N T E RD EL FU E R T E OLIVENHAIN RD. ME L R O S E DR . FARADAY COLLE G E BL V D PAS E O DEL NO R T E AVE AV E N I D A EN C I N A S CANNON RD MO N R O E ST CARL S B A D VILLAGE DR MARRON TAMAR A C K AVE RD LAKECALAVERABUEN A VIST A LAGO O N AGUA HEDIOND A LAGOO N BATIQUITOSLAGOON AV I A R A PKWY VICINITY MAP CONSTRUCTION PLANS CITY COUNCIL CARLSBAD, CALIFORNIA KEITH BLACKBURN - MAYOR MELANIE BURKHOLDER - COUNCIL MEMBER PRIYA BHAT-PATEL - MAYOR PRO TEM TERESA ACOSTA - COUNCIL MEMBER CAROLYN LUNA - COUNCIL MEMBER GENERATOR REPLACEMENT FOR LOCATION MAP N POINSET T I A LANE SHEET INDEX SHEET NUMBER DESCRIPTION DRAWING NUMBER 1 TITLE SHEET, LOCATION MAPS, AND SHEET INDEX G-1 2 CSGBC NON-RESIDENTIAL CHECKLIST - I G-2 3 CSGBC NON-RESIDENTIAL CHECKLIST - II G-3 4 CSGBC NON-RESIDENTIAL CHECKLIST - III G-4 5 CIVIL ABBREVIATIONS AND NOTES C-1 6 CIVIL LEGEND C-2 7 OVERALL SITE PLAN AND KEY MAP C-3 8 CIVIL DEMO AND SITE PLAN C-4 9 CIVIL GRADING AND UTILITY PLAN C-5 10 CIVIL DETAILS C-6 11 GENERAL ELECTRICAL ABBREVIATIONS AND NOTES E-1 12 GENERAL ELECTRICAL LEGEND - I E-2 13 GENERAL ELECTRICAL LEGEND - II E-3 14 ELECTRICAL DEMOLITION DETAILS E-4 15 ELECTRICAL SITE PLAN E-5 16 SINGLE LINE DIAGRAM - DEMO AND REVISED E-6 17 PANELBOARD SCHEDULE E-7 18 GENERATOR BUILDING DEMOLITION AND MODIFIED PLANS E-8 19 ELECTRICAL ROOM DEMOLITION AND MODIFIED PLANS E-9 20 STANDARD ELECTRICAL DETAILS E-10 21 GENERATOR BUILDING DEMOLITION AND MODIFIED PLANS/SECTION M-1 22 GENERATOR BUILDING MECHANICAL DETAILS M-2 23 STRUCTURAL GENERAL NOTES, ABBREVIATIONS, & SPECIAL INSPECTIONS S-1 24 STRUCTURAL STANDARD DETAILS S-2 25 STRUCTURAL GENERATOR ROOM FOUNDATION PLAN S-3 HWY 78 I-5 I-5 City ofCarlsbad POINSETTIA LIFT STATION REFERENCE DRAWINGS DWG. NO.DRAWING TITLE 331-1E POINSETTIA SEWAGE LIFT STATION (1997) 451-2 POINSETTIA SEWAGE LIFT STATION UPGRADE (2007) 486-6 POINSETTIA LIFT STATION STANDBY PUMP SYSTEM (2017) 486-6A POINSETTIA LIFT STATION HYDRAULIC SURGE PROTECTION (2020) PROJECT LOCATION POINSE T T I A LANE BATIQUITOSLAGOON AIRP O R T RD AL I C A N T E RD EL F U E R T E S T EL F U E R T E S T AVIA R A P K W Y ALGA RD POINSETTIA LAN E CAMINO VID A R O B L E CA M I N O EL RE A L PROJECT LOCATION I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR THE PROJECT DESIGN. KENNEDY/JENKS CONSULTANTS 9325 SKY PARK COURT, SUITE 300 SAN DIEGO, CA 92123 858-676-7500 DECLARATION OF RESPONSIBLE CHARGE BY:DATE: R.C.E. NO.: REGISTRATION EXPIRATION DATE: NOVEMBER 2023 N PROJECT NO. 3840-23 POINSETTIA LIFT STATION 2351 Geode Lane Carlsbad, CA 92009 SEWER LIFT STATION UPGRADE PROGRAM REFERENCED APPLICABLE CODES 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE (CEnC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) PROJECT NARRATIVE: THE PROJECT INCLUDES THE REPLACEMENT OF A STANDBY ENGINE-GENERATOR INSTALLATION WITH A SUB-BASE FUEL TANK WITHIN THE CHEMICAL STORAGE/GENERATOR BUILDING AND THE REPLACEMENT OF AN AUTOMATIC TRANSFER SWITCH WITHIN THE CONTROL/PUMP STATION BUILDING. THE PROJECT ALSO INCLUDES THE ADDITION OF A NEW MANUAL TRANSFER SWITCH AND ASSOCIATED CONDUIT AND WIRING OUTSIDE OF THE CHEMICAL STORAGE/GENERATOR BUILDING AND RECEPTACLE FOR INTERCONNECTION TO A PORTABLE GENERATOR. REROUTING OF EXIST UTILITIES, PATCHING OF PAVEMENT IS ALSO INCLUDED. THE PROJECT ALSO INCLUDES REPLACEMENT EXHAUST AND VENT SYSTEM PIPING FOR THE ENGINE-GENERATOR AND FUEL TANK ASSEMBLY, REPLACEMENT LOUVERS AND EXHAUST VENTILATION SYSTEM FOR THE GENERATOR ROOM. FACILITY INFORMATION CATEGORY/CRITERIA GENERATOR/CHEMICAL STORAGE BUILDING CONTROL/PUMP BUILDING CONTRUCTION TYPE TYPE II-B, PER CBC 602.2 SINGLE STORY, SLAB-ON-GRADE FLOOR, METAL ROOF OVER METAL FRAMING TYPE II-B, PER CBC 602.2 SINGLE STORY, OVER BASEMENT MECHANICAL EQUIPMENT ROOM, SEPARATION TO BURIED SEWAGE WET WELL WITH MANHOLE ACCESS, METAL ROOF OVER METAL FRAMING ALLOWABLE AREA 15,500 SF 15,500 SF ACTUAL AREA 661 SF 1,170 SF OCCUPANCY CLASSIFICATIONS GENERATOR ROOM, 'F-1', 338 SF CONTROL ROOM, 'F-1', 423 SF BLOWER ROOM, 'F-1',151 SF (NO NEW WORK)LAVATORY, 'F-1', 40 SF (NO NEW WORK) CHEMICAL STORAGE ROOM, 'F-1', 172 SF (NO NEW WORK)UTILITY ENCLOSURE, 'U', 43 SF (NO NEW WORK) -PUMP ROOM (BASEMENT), 'F-1', 664 SF (NO NEW WORK) -SEWAGE WET WELL, 'U', 251 SF (NO NEW WORK) OCCUPANCY SEPARATIONS PER NFPA 37, 1-HOUR SEPARATION REQUIRED AT GENERATOR ROOM TO ADJACENT SPACES EXISTING 2-HOUR SEPARATIONS PROVIDED BETWEEN 'F-1' AND 'U' OCCUPANCIES CHEMICAL STOAGE DIESEL FUEL (CAS 000169-00-0), CLASS 2 COMBUSTIBLE LIQUID, 400 GALLONS - GENERATOR ROOM (NONE) BIOXIDE®, AMMONIUM CALCIUM NITRATE SALT SOLUTION (CAS 15245-12-2), NO HAZARDOUS CLASSIFICATION 1500 GALLONS - CHEMICAL STORAGE ROOM - TIMOTHY WATERS C86080 09/30/2024 11-22-2023 1 TITLE SHEET, LOCATION MAPS, G-1 AND SHEET INDEX EA TW - POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) TIMOTHY WATERS No. C86080 C I V I L Exp. 9/30/24 DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 CHAPTER 5 NONRESIDENTIAL MANDATORY MEASURES SECTION 5.101 GENERAL 5.101.1 SCOPE The provisions of this chapter outline planning, design and development methods that include environmentally responsible site selection, building design, building siting and development to protect, restore and enhance the environmental quality of the site and respect the integrity of adjacent properties. DIVISION 5.1 PLANNING AND DESIGN Y SECTION 5.102 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) CUTOFF LUMINAIRES. Luminaires whose light distribution is such that the candela per 1000 lamp lumens does not numerically exceed 25 (2.5 percent) at an angle of 90 degrees above nadir, and 100 (10 percent) at a vertical angle of 80 degrees above nadir. This applies to all lateral angles around the luminaire. LOW-EMITTING AND FUEL EFFICIENT VEHICLES. Eligible vehicles are limited to the following: 1. Zero emission vehicle (ZEV), enhanced advanced technology PZEV (enhanced AT ZEV) or transitional zero emission vehicles (TZEV) regulated under CCR, Title 13, Section 1962. 2. High-efficiency vehicles, regulated by U.S. EPA, bearing a fuel economy and greenhouse gas rating od 9 oe 10 as regulated under 40 CFR Section 600 Subpart D. NEIGHBORHOOD ELECTRIC VEHICLE (NEV). A motor vehicle that meets the definition of "low-speed vehicle" either in Section 385.5 of the Vehicle Code or in 49CFR571.500 (as it existed on July 1, 2000), and is certified to zero-emission vehicle standards. TENANT-OCCUPANTS. Building occupants who inhabit a building during its normal hours of operation as permanent occupants, such as employees, as distinguished from customers and other transient visitors. VANPOOL VEHICLE. Eligible vehicles are limited to any motor vehicle, other than a motortruck or truck tractor, designed for carrying more than 10 but not more than 15 persons including the driver, which is maintained and used primarily for the nonprofit work-related transportation of adults for the purpose of ridesharing. Note: Source: Vehicle Code, Division 1, Section 668 ZEV. Any vehicle certified to zero-emission standards. SECTION 5.106 SITE DEVELOPMENT 5.106.1 STORM WATER POLLUTION PREVENTION FOR PROJECTS THAT DISTURB LESS THAN ONE ACRE OF LAND. Newly constructed projects and additions which disturb less than one acre of land, and are not part of a larger common plan of development or sale, shall prevent the pollution of storm water runoff from the construction activities through one or more of the following measures: 5.106.1.1 Local ordinance. Comply with a lawfully enacted storm water management and/or erosion control ordinance. 5.106.1.2 Best Management Practices (BMPs). Prevent the loss of soil through wind or water erosion by implementing an effective combination of erosion and sediment control and good housekeeping BMPs. 1. Soil loss BMPs that should be considered for implementation as appropriate for each project include, but are not limited to, the following: a. Scheduling construction activity during dry weather, when possible. b. Preservation of natural features, vegetation, soil, and buffers around surface waters. c. Drainage swales or lined ditches to control stormwater flow. d. Mulching or hydroseeding to stabilize disturbed soils. e. Erosion control to protect slopes. f. Protection of storm drain inlets (gravel bags or catch basin inserts). g. Perimeter sediment control (perimeter silt fence, fiber rolls). h. Sediment trap or sediment basin to retain sediment on site. i. Stabilized construction exits. j. Wind erosion control. k. Other soil loss BMPs acceptable to the enforcing agency. 2. Good housekeeping BMPs to manage construction equipment, materials, non-stormwater discharges and wastes that should be considered for implementation as appropriate for each project include, but are not limited to, the following: a. Dewatering activities. b. Material handling and waste management. c. Building materials stockpile management. d. Management of washout areas (concrete, paints, stucco, etc.). e. Control of vehicle/equipment fueling to contractor's staging area. f. Vehicle and equipment cleaning performed off site. g Spill prevention and control. h. Other housekeeping BMPs acceptable to the enforcing agency. DIVISION 5.2 ENERGY EFFICIENCY SECTION 5.201 GENERAL 5.201.1 Scope [BSC-CG]. California Energy Code [DSA-SS]. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory building standards. DIVISION 5.3 WATER EFFICIENCY AND CONSERVATION SECTION 5.301 GENERAL 5.301.1 Scope. The provisions of this chapter shall establish the means of conserving water use indoors, outdoors and in wastewater conveyance. SECTION 5.302 DEFINITIONS 5.302.1 Definitions. The following terms are defined in Chapter 2 (and are included here for reference) EVAPOTRANSPIRATION ADJUSTMENT FACTOR (ETAF) [DSA-SS]. An adjustment factor when applied to reference evapotranspiration that adjusts for plant factors and irrigation efficiency, which ae two major influences on the amount of water that needs to be applied to the landscape. FOOTPRINT AREA [DSA-SS]. The total area of the furthest exterior wall of the structure projected to natural grade, not including exterior areas such as stairs, covered walkways, patios and decks. METERING FAUCET. A self-closing faucet that dispenses a specific volume of water for each actuation cycle. The volume or cycle duration can be fixed or adjustable. GRAYWATER. Pursuant to Health and Safety Code Section 17922.12, "graywater" means untreated wastewater that has not been contaminated by any toilet discharge, has not been affected by infectious, contaminated, or unhealthy bodily wastes, and does not present a threat from contamination by unhealthful processing, manufacturing, or operating wastes. "Graywater" includes, but is not limited to wastewater from bathtubs, showers, bathroom washbasins, clothes washing machines and laundry tubs, but does not include waste water from kitchen sinks or dishwashers. MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO). The California ordinance regulating landscape design, installation and maintenance practices that will ensure commercial, multifamily and other developer installed landscapes greater than 2500 square feet meet an irrigation water budget developed based on landscaped area and climatological parameters. MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO). [HCD] The California model ordinance (California Code of Regulations, Title 23, Division 2, Chapter 2.7), regulating landscape design, installation and maintenance practices. Local agencies are required to adopt the updated MWELO, or adopt a local ordinance at least as effective as the MWELO. POTABLE WATER. Water that is drinkable and meets the U.S. Environmental Protection Agency (EPA) Drinking Water Standards. See definition in the California Plumbing Code, Part 5. POTABLE WATER. [HCD] Water that is satisfactory for drinking, culinary, and domestic purposes, and meets the U.S. Environmental Protection Agency (EPA) Drinking Water Standards and the requirements of the Health Authority Having Jurisdiction. RECYCLED WATER. Water which, as a result of treatment of waste, is suitable for a direct beneficial use or a controlled use that would not otherwise occur [Water Code Section 13050 (n)]. Simply put, recycled water is water treated to remove waste matter attaining a quality that is suitable to use the water again. SUBMETER. [HCD 1] A secondary device beyond a meter that measures water consumption of an individual rental unit within a multiunit residential structure or mixed-use residential and commercial structure. (See Civic Code Section 1954.202 (g) and Water code Section 517 for additional details.) WATER BUDGET. Is the estimated total landscape irrigation water use which shall not exceed the maximum applied water allowance calculated in accordance with the Department of Water Resources Model Efficient Landscape Ordinance (MWELO). 5.106.5.3 Electric vehicle (EV) charging. [N] Construction to provide electric vehicle infrastructure and facilitate electric vehicle charging shall comply with Section 5.106.5.3.1 and shall be provided in accordance with regulations in the California Building Code and the California Electrical Code. Exceptions: 1.On a case-by-case basis where the local enforcing agency has determined compliance with this section is not feasible based upon one of the following conditions: a.Where there is no local utility power supply b.Where the local utility is unable to supply adequate power. c.Where there is evidence suitable to the local enforcement agency substantiating the local utility infrastructure design requirements, directly related to the implementation of Section 5.106.5.3, may adversely impact the construction cost of the project. 2. Parking spaces accessible only by automated mechanical car parking systems are not required to comply with this code section 5.106.5.3.1 EV capable spaces. [N] EV capable spaces shall be provided in accordance with Table 5.106.5.3.1 and the following requirements: 1.Raceways complying with the California Electrical Code and no less that 1-inch (25 mm) diameter shall be provided and shall originate at a service panel or a subpanel(s) serving the area, and shall terminate in close proximity to the proposed location of the EV capable and into a suitable listed cabinet, box,enclosure or equivalent. A common raceway may be used to serve multiple EV charging spaces. 2.A service panel or subpanel (s) shall be provided with panel space and electrical load capacity for a dedicated 208/240 volt, 40-ampere minimum branch circuit for each EV capable space, with delivery of 30-ampere minimum to an installed EVSE at each EVCS. 3.The electrical system and any on-site distribution transformers shall have sufficient capacity to supply full rated amperage at each EV capable space. 4.The service panel or subpanel circuit directory shall identify the reserved overcurrent protective devices space(s) as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE." Note: A parking space served by electric vehicle supply equipment or designed as a future EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by an enforcement agency. See vehicle Code Section 22511.2 for further details. ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New 5.106.4.1.2 Long-term bicycle parking. For new buildings with tenant spaces that have 10 or more tenant-occupants, provide secure bicycle parking for 5 percent of the tenant-occupant vehicular parking spaces with a minimum of one bicycle parking facility. 5.106.4.1.3 For additions or alterations that add 10 or more tenant-occupant vehicular parking spaces, provide secure bicycle parking for 5 percent of the tenant vehicular parking spaces being added, with a minimum of one bicycle parking facility. 5.106.4.1.4 For new shell buildings in phased projects provide secure bicycle parking for 5 percent of the anticipated tenant-occupant vehicular parking spaces with a minimum of one bicycle parking facility. 5.106.4.1.5 Acceptable bicycle parking facility for Sections 5.106.4.1.2, 5.106.4.1.3, and 5.106.4.1.4 shall be convenient from the street and shall meet one of the following: 1. Covered, lockable enclosures with permanently anchored racks for bicycles; 2. Lockable bicycle rooms with permanently anchored racks; or 3. Lockable, permanently anchored bicycle lockers. Note: Additional information on recommended bicycle accommodations may be obtained from Sacramento Area Bicycle Advocates. 5.106.4.2 Bicycle parking. [DSA-SS] For public schools and community colleges, comply with Sections 5.106.4.2.1 and 5.106.4.2.2 5.106.4.2.1 Student bicycle parking. Provide permanently anchored bicycle racks conveniently accessed with a minimum of four two-bike capacity racks per new building. 5.106.4.2.2 Staff bicycle parking. Provide permanent, secure bicycle parking conveniently accessed with a minimum of two staff bicycle parking spaces per new building. Acceptable bicycle parking facilities shall be convenient from the street or staff parking area and shall meet one of the following: 1. Covered, lockable enclosures with permanently anchored racks for bicycles; 2. Lockable bicycle rooms with permanently anchored racks; or 3. Lockable, permanently anchored bicycle lockers. 5.106.4 BICYCLE PARKING. For buildings within the authority of California Building Standards Commission as specified in Section 103, comply with Section 5.106.4.1. For buildings within the authority of the Division of the State Architect pursuant to Section 105, comply with Section 5.106.4.2 5.106.4.1 Bicycle parking. [BSC-CG] Comply with Sections 5.106.4.1.1 and 5.106.4.1.2; or meet the applicable local ordinance, whichever is stricter. 5.106.4.1.1 Short-term bicycle parking. If the new project or an addition or alteration is anticipated to generate visitor traffic, provide permanently anchored bicycle racks within 200 feet of the visitors' entrance, readily visible to passers-by, for 5% of new visitor motorized vehicle parking spaces being added, with a minimum of one two-bike capacity rack. Exception: Additions or alterations which add nine or less visitor vehicular parking spaces. CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.3 NONRESIDENTIAL ADDITIONS AND ALTERATIONS. [BSC-CG] The provisions of individual sections of Chapter 5 apply to newly constructed buildings, building additions of 1,000 square feet or greater, and/or building alterations with a permit valuation of $200,000 or above (for occupancies within the authority of California Building Standards Commission). Code sections relevant to additions and alterations shall only apply to the portions of the building being added or altered within the scope of the permitted work. A code section will be designated by a banner to indicate where the code section only applies to newly constructed buildings [N] or to additions and/or alterations [A]. When the code section applies to both, no banner will be used. 301.3.1 Nonresidential additions and alterations that cause updates to plumbing fixtures only: Note: On and after January 1, 2014, certain commercial real property, as defined in Civil Code Section 1101.3, shall have its noncompliant plumbing fixtures replaced with appropriate water-conserving plumbing fixtures under specific circumstances. See Civil Code Section 1101.1 et seq. for definitions, types of commercial real property affected, effective dates, circumstances necessitating replacement of noncompliant plumbing fixtures, and duties and responsibilities for ensuring compliance. 301.3.2 Waste Diversion. The requirements of Section 5.408 shall be required for additions and alterations whenever a permit is required for work. 301.4 PUBLIC SCHOOLS AND COMMUNITY COLLEGES. (see GBSC) 301.5 HEALTH FACILITIES. (see GBSC) SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. SECTION 303 PHASED PROJECTS 303.1 PHASED PROJECTS. For shell buildings and others constructed for future tenant improvements, only those code measures relevant to the building components and systems considered to be new construction (or newly constructed) shall apply. 303.1.1 Initial Tenant improvements. The provisions of this code shall apply only to the initial tenant improvements to a project. Subsequent tenant improvements shall comply with the scoping provisions in Section 301.3 non-residential additions and alterations. 5.106.5.3.3 Use of automatic load management systems (ALMS). ALMS shall be permitted for EVCS. When ALMS is installed, the required electrical load capacity specified in Section 5.106.5.3.1 for each EVCS may be reduced when serviced by an EVSE controlled by an ALMS. Each EVSE controlled by an ALMS shall deliver a minimum 30 amperes to an EV when charging one vehicle and shall deliver a minimum 3.3 kW while simultaneously charging multiple EVs. 5.106.5.3.4 Accessible EVCS. When EVSE is installed, accessible EVSC shall be provided in accordance with the California Building Code, Chapter 11B, Section 11B-228.3. Note: For EVCS signs, refer to Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 5.106.5.4 Electric Vehicle (EV) charging: medium-duty and heavy-duty. [N] Construction shall comply with section 5.106.5.4.1 to facilitate future installation of electric vehicle supply equipment (EVSE). Construction for warehouses, grocery stores and retail stores with planned off-street loading spaces shall also comply with Section 5.106.5.4.1 for future installation of medium- and heavy-duty EVSE. Exceptions: 1.On a case-by-case basis where the local enforcing agency has determined compliance with this section is not feasible based upon one of the following conditions: a.Where there is no local utility power supply. b.Where the local utility is unable to supply adequate power. c.Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 5.106.5.3, may adversely impact the construction cost of the project. When EVSE(s) is/are installed, it shall be in accordance with the California Building Code, the California Electrical Code and as follows: 5.106.5.4.1 Electric vehicle charging readiness requirements for warehouse, grocery stores and retail stores with planned off-street loading spaces. [N]In order to avoid future demolition when adding EV charging supply and distribution equipment, spare raceways(s) or busway(s) and adequate capacity for transformers(s), service panels(s) or subpanel(s) shall be installed at the time of construction in accordance with the California Electrical Code. Construction plans and specifications shall include but are not limited to, the following: 1.The transformer, main service equipment and subpanel shall meet the minimum power requirement in Table 5.106.5.4.1 to accommodate the dedicated branch circuits for the future installation of EVSE. 2.The construction documents shall indicate on or more location(s) convenient to the planned offstreet loading space(s) reserved for medium-and heavy-duty ZEV charging cabinets and charging dispensers, and a pathway reserved for routing of conduit from the termination of the raceway(s) or busway(s) to the charging cabinet(s) and dispenser(s) as shown in Table 5.106.5.4.1 3.Raceway(s) or busway(s) originating at a main service panel or a subpanel(s) serving the area where potential future medium-and heavy-duty EVSE will be located and shall terminate in close proximity to the potential future location of the charging equipments for medium- and heavy-duty vehicles. 4.The raceway(s) or busway(s) shall be sufficient size to carry the minimum additional system load to the future location of the charging for medium- and heavy-duty ZEVs as shown in Table 5.106.5.4.1. TABLE 5.106.5.3.1 TOTAL NUMBER OF ACTUAL PARKING SPACES NUMBER OF REQUIRED EV CAPABLE SPACES NUMBER OF EVCS (EV CAPABLE SPACES PROVIDED WITH EVSE)^2 0-9 0 0 10-25 2 0 26-50 8 2 51-75 13 3 76-100 17 4 101-150 25 6 151-200 35 9 201 AND OVER 20% of total¹25% of EV capable spaces¹ 5.106.8 LIGHT POLLUTION REDUCTION. [N]. l Outdoor lighting systems shall be designed and installed to comply with the following: 1.The minimum requirements in the California Energy Code for Lighting Zones 0-4 as defined in Chapter 10, Section 10-114 of the California Administrative Code; and 2.Backlight (B) ratings as defined in IES TM-15-11 (shown in Table A-1 in Chapter 8); 3.Uplight and Glare ratings as defined in California Energy Code (shown in Tables 130.2-A and 130.2-B in Chapter 8) and 4.Allowable BUG ratings not exceeding those shown in Table 5.106.8, [N] or Comply with a local ordinance lawfully enacted pursuant to Section 101.7, whichever is more stringent. Exceptions: [N] 1. Luminaires that qualify as exceptions in Sections 130.2 (b) and 140.7 of the California Energy Code. 2. Emergency lighting. 3. Building facade meeting the requirements in Table 140.7-B of the California Energy Code, Part 6. 4. Custom lighting features as allowed by the local enforcing agency, as permitted by Section 101.8 Alternate materials, designs and methods of construction. 5. Luminaires with less than 6,200 initial luminaire lumens. TABLE 5.106.8 [N] MAXIMUM ALLOWABLE BACKLIGHT, UPLIGHT AND GLARE (BUG) RATINGS 1,2 ALLOWABLE RATING LIGHTING ZONE LZ0 LIGHTING ZONE LZ1 LIGHTING ZONE LZ2 LIGHTING ZONE LZ3 LIGHTING ZONE LZ4 MAXIMUM ALLOWABLE BACKLIGHT RATING 3 Luminaire greater than 2 mounting heights (MH) from property line N/A No Limit No Limit No Limit No Limit Luminaire back hemisphere is 1-2 MH from property line N/A B2 B3 B4 B4 Luminaire back hemisphere is 0.5-1 MH from property line N/A B1 B2 B3 B3 Luminaire back hemisphere is less than 0.5 MH from property line N/A B0 B0 B1 B2 MAXIMUM ALLOWABLE UPLIGHT RATING (U) For area lighting 3 N/A U0 U0 U0 U0 For all other outdoor lighting,including decorative luminaires N/A U1 U2 U3 UR DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. 5.106.2 STORMWATER POLLUTION PREVENTION FOR PROJECTS THAT DISTURB ONE OR MORE ACRES OF LAND. Comply with all lawfully enacted stormwater discharge regulations for projects that (1) disturb one acre or more of land, or (2) disturb less than one acre of land but are part of a larger common plan of development sale. Note: Projects that (1) disturb one acre or more of land, or (2) disturb less than one acre of land but are part of the larger common plan of development or sale must comply with the post-construction requirements detailed in the applicable National Pollutant Discharge Elimination System (NPDES) General permit for Stormwater Discharges Associated with Construction and Land Disturbance Activities issued by the State Water Resources Control Board or the Lahontan Regional Water Quality Control Board (for projects in the Lake Tahoe Hydrologic Unit). The NPDES permits require postconstruction runoff (post-project hydrology) to match the preconstruction runoff (pre-project hydrology) with the installation of postconstruction stormwater management measures. The NPDES permits emphasize runoff reduction through on-site stormwater use, interception, evapotranspiration, and infiltration through nonstructural controls, such as Low Impact Development (LID) practices, and conversation design measures. Stormwater volume that cannot be addressed using nonstructural practices is required to be captured in structural practices and be approved by the enforcing agency. Refer to the current applicable permits on the State Water Resources Control Board website at: www.waterboards.ca.gov/constructionstormwater. Consideration to the stormwater runoff management measures should be given during the initial design process for appropriate integration into site development. N/A Y N/A 1.Where there is insufficient electrical supply. 2.The number of required EVCS (EV capable spaces provided with EVSE) in column 3 count towards the total number of required EV capable spaces shown in column 2. 5.106.5.3.2 Electric vehicle charging stations (EVCS) EV capable spaces shall be provided with EVSE to create EVCS in the number indicated in Table 5.106.5.3.1. The EVCS required by Table 5.106.5.3.1 may be provided with EVSE in any combination of Level 2 and Direct Current Fast Charging (DCFC), except that at least one Level 2 EVSE shall be provided. One EV charger with multiple connectors capable of charging multiple EVs simultaneously shall be permitted if the electrical load capacity required by Section 5.106.5.3.1 for each EV capable space is accumulatively supplied to the EV charger. The installation of each DCFC EVSE shall be permitted to reduce the minimum number of required EV capable spaces without EVSE by five and reduce proportionally the required electrical load capacity to the service panel or subpanel. Y N/A Y N/ARESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 5.106.8.1 Facing- Backlight Luminaries within 2MH of a property line shall be oriented so that the nearest property line is behind the fixture, and shall comply with the backlight rating specified in Table 5.106.8 based on the lighting zone and distance to the nearest point of that property line. Exception: Corners. If two property lines (or two segments of the same property line) have equidistant point to the luminaire, then the luminaire may be oriented so that the intersection of the two lines (the corner) is directly behind the luminaire. The luminaire shall still use the distance to the nearest points(s) on the property lines to determine the required backlight rating. 5.106.8.2 Facing-Glare. For luminaires covered by 5.106.8.1, if a property line also exists within or extends into the front hemisphere within 2MH of the luminaire then the luminaire shall comply with the more stringent glare rating specified in Table 5.106.8 based on the lighting zone and distance to the nearest point on the nearest property line within the front hemisphere. Note: [N] 1.See also California Building Code, Chapter 12, Section 1205.6 for college campus lighting requirements for parking facilities and walkways. 2.Refer to Chapter 8 (Compliance Forms, Worksheets and Reference Material) for IES TM-15-11 Table A-1, California Energy Code Tables 130.2-A and 130.2-B. 3. Refer to the California Building Code for requirements for additions and alterations. 5.106.10 GRADING AND PAVING. Construction plans shall indicate how site grading or a drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1.Swales. 2.Water collection and disposal systems. 3.French drains. 4.Water retention gardens. 5.Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 5.106.12 SHADE TREES [DSA-SS]. Shade Trees shall be planted to comply with Sections 5.106.12.1, 5.106.12.2, and 5.106.12.3. Percentages shown shall be measured at noon on the summer solstice. Landscape irrigation necessary to establish and maintain tree health shall comply with Section 5.304.6. 5.106.12.1 Surface parking areas. Shade tree plantings, minimum #10 container size or equal, shall be installed to provide shade over 50 percent of the parking area within 15 years. Exceptions: Surface parking area covered by solar photovoltaic shade structures with roofing materials that comply with Table A5.106.11.2.2 in Appendix A5 shall be permitted in whole or in part in lieu of shade tree planting. 5.106.12.2 Landscape areas. Shade tress plantings, minimum #10 container size or equal shall be installed to provide shade of 20% of the landscape area within 15 years. Exceptions: Playfields for organized sport activity are not included in the total area calculation. 5.106.12.3. Hardscape areas. Shade tree plantings, minimum #10 container size or equal shall be installed to provide shade over 20 percent of the hardscape area within 15 years. Exceptions: 1.Walks, hardscape areas covered by solar photovoltaic shade structures or shade structures with roofing materials that comply with Table A5.106.11.2.2 in Appendix A5 shall be permitted in whole or in part in lieu of shade tree planting. 2.Designated and marked play areas of organized sport activity are not included in the total area calculation. TABLE 5.106.5.4.1 RACEWAY CONDUIT AND PANEL POWER REQUIREMENTS FOR MEDIUM- AND HEAVY-DUTY EVSE [N] BUILDING TYPE BUILDING SIZE (SQ. FT.) NUMBER OF OFF-STREET LOADING SPACES ADDITIONAL CAPACITY REQUIRED (KVA) FOR RACEWAY & BUSWAY AND TRANSFORMER & PANEL Grocery 10,000 to 90,000 1 or 2 200 3 or Greater 400 Greater than 90,000 1 or Greater 400 Retail 10,000 to 135,000 1 or 2 200 3 or Greater 400 Greater than 135,000 1 or Greater 400 Warehouse 20,000 to 256,000 1 or 2 200 3 or Greater 400 Greater than 256,000 1 or Greater 400 MAXIMUM ALLOWABLE GLARE RATING 5 (G) MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G1 G2 G3 G4 MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G0 G1 G1 G2 MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G0 G0 G1 G1 MAXIMUM ALLOWABLE GLARE RATING 5 (G)N/A G0 G0 G0 G1 1. IESNA Lighting Zones 0 and 5 are not applicable; refer to Lighting Zones as defined in the California Energy Code and Chapter 10 of the Callifornia Administrative Code. 2. For property lines that abut public walkways, bikeways, plazas and parking lots, the property line may be considered to be 5 feet beyond the actual property line for purpose of determining compliance with this section. For property lines that abut public roadways and public transit corridors, the property line may be considered to be the centerline of the public roadway or public transit corridor for the purpose of determining compliance with this section. 3. General lighting luminaires in areas such as outdoor parking, sales or storage lots shall meet these reduced ratings. Decorative luminaries located in these areas shall meet U-value limits for "all other outdoor lighting" DOC. REF. DOC. REF. DOC. REF. DOC. REF. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE NONRESIDENTIAL MANDATORY MEASURES, SHEET 1 (January 2023) Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) DOC. REF.=DOCUMENT REFERENCE POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) ZACHARY D. HARRIS No. M28906 Exp. 6/30/24 M E C H A N I C A L CSGBC NON-RESIDENTIAL CHECKLIST - I X X X X X X X 2 G-2 EA ZDH TW DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: 5.303.3.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-Type toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 5.303.3.2 Urinals. 5.303.3.2.1 Wall-mounted Urinals. The effective flush volume of wall-mounted urinals shall not exceed 0.125 gallons per flush. 5.303.3.2.2 Floor-mounted Urinals. The effective flush volume of floor-mounted or other urinals shall not exceed 0.5 gallons per flush. 5.303.3.3 Showerheads. [BSC-CG] 5.303.3.3.1 Single showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 5.303.3.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. DIVISION 5.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY SECTION 5.401 GENERAL 5.401.1 SCOPE. The provisions of this chapter shall outline means of achieving material conservation and resource efficiency through protection of buildings from exterior moisture, construction waste diversion, employment of techniques to reduce pollution through recycling of materials, and building commissioning or testing and adjusting. SECTION 5.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 5.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65% of the non-hazardous construction and demolition waste in accordance with Section 5.408.1.1, 5.408.1.2 or 5.408.1.3; or meet a local construction and demolition waste management ordinance, whichever is more stringent. 5.408.1.1 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, submit a construction waste management plan that: 1. Identifies the construction and demolition waste materials to be diverted from disposal by efficient usage, recycling, reuse on the project or salvage for future use or sale. 2. Determines if construction and demolition waste materials will be sorted on-site (source-separated) or bulk mixed (single stream). 3. Identifies diversion facilities where construction and demolition waste material collected will be taken. 4. Specifies that the amount of construction and demolition waste materials diverted shall be calculated byweight or volume, but not by both. 5.408.1.2 Waste Management Company. Utilize a waste management company that can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with this section. Note: The owner or contractor shall make the determination if the construction and demolition waste material will be diverted by a waste management company. Exceptions to Sections 5.408.1.1 and 5.408.1.2: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist. 3. Demolition waste meeting local ordinance or calculated in consideration of local recycling facilities and markets. 5.408.1.3 Waste stream reduction alternative. The combined weight of new construction disposal that does not exceed two pounds per square foot of building area may be deemed to meet the 65% minimum requirement as approved by the enforcing agency. 5.408.1.4 Documentation. Documentation shall be provided to the enforcing agency which demonstrates compliance with Sections 5.408.1.1, through 5.408.1.3. The waste management plan shall be updated as necessary and shall be accessible during construction for examination by the enforcing agency. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Nonresidential)" located www.dgs.ca.gov/BSC/Resources/Page-Content/Building-Standards-Commission- Resources-List-Folder/CALGreen may be used to assist in documenting compliance with the waste management plan. 2. Mixed construction and demolition debris processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 5.408.2 UNIVERSAL WASTE. [A] Additions and alterations to a building or tenant space that meet the scoping provisions in Section 301.3 for nonresidential additions and alterations, shall require verification that Universal Waste items such as fluorescent lamps and ballast and mercury containing thermostats as well as other California prohibited Universal Waste materials are disposed of properly and are diverted from landfills. A list of prohibited Universal Waste materials shall be included in the construction documents. Note: Refer to the Universal Waste Rule link at: http://www.dtsc.ca.gov/universalwaste/ 5.408.3 EXCAVATED SOIL AND LAND CLEARING DEBRIS. 100 percent of trees, stumps, rocks and associated vegetation and soils resulting primarily from land clearing shall be reused or recycled. For a phased project, such material may be stockpiled on site until the storage site is developed. Exception: Reuse, either on or off-site, of vegetation or soil contaminated by disease or pest infestation. Notes: 1. If contamination by disease or pest infestation is suspected, contact the County Agricultural Commissioner and follow its direction for recycling or disposal of the material. 2. For a map of know pest and/or disease quarantine zones, consult with the California Department of Food and Agriculture. (www.cdfa.ca.gov) DIVISION 5.5 ENVIRONMENTAL QUALITY SECTION 5.501 GENERAL 5.501.1 SCOPE. The provisions of this chapter shall outline means of reducing the quantity of air contaminants that are odorous, irritating, and/or harmful to the comfort and well-being of a building's installers, occupants and neighbors. SECTION 5.502 DEFINITIONS 5.502.1 DEFINITIONS. The following terms are defined in Chapter 2 (and are included here for reference) ARTERIAL HIGHWAY. A general term denoting a highway primarily for through traffic usually on a continuous route. A-WEIGHTED SOUND LEVEL (dBA). The sound pressure level in decibels as measured on a sound level meter using the internationally standardized A-weighting filter or as computed from sound spectral data to which A-weighting adjustments have been made. 1 BTU/HOUR. British thermal units per hour, also referred to as Btu. The amount of heat required to raise one pound of water one degree Fahrenheit per hour, a common measure of heat transfer rate. A ton of refrigeration is 12,000 Btu, the amount of heat required to melt a ton (2,000 pounds) of ice at 320 Fahrenheit. COMMUNITY NOISE EQUIVALENT LEVEL (CNEL). A metric similar to the day-night average sound level (Ldn), except that a 5 decibel adjustment is added to the equivalent continuous sound exposure level for evening hours (7pm to 10pm) in addition to the 10 dB nighttime adjustment used in the Ldn. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. “Composite wood products” does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, timber, prefabricated wood I–joists or finger–jointed lumber, all as specified in California Code of Regulations (CCR), Title 17, Section 93120.1(a). Note: See CCR, Title 17, Section 93120.1. DAY-NIGHT AVERAGE SOUND LEVEL (Ldn). The A-weighted equivalent continuous sound exposure level for a 24-hour period with a 10 dB adjustment added to sound levels occurring during nighttime hours (10p.m. to 7 a.m.). DECIBEL (db). A measure on a logarithmic scale of the magnitude of a particular quantity (such as sound pressure, sound power, sound intensity) with respect to a reference quantity. ELECTRIC VEHICLE (EV). An automotive-type vehicle for on-road use, such as passenger automobiles, buses, trucks, vans, neighborhood electric vehicles, electric motorcycles, and the like, primarily powered by an electric motor that draws current from a rechargeable storage battery, fuel cell, photovoltaic array, or other source of electric current. Plug-in hybrid electric vehicles (PHEV) are considered electric vehicles. For purposes of the California Electrical Code, off-road, self-propoelled electric vehicles, such as industrial trucks, hoists, lifts, transports, golf carts, airline ground support equipment, tractors, boats, and the like, are not included. ELECTRIC VEHICLE CHARGING STATION(S) (EVCSj). One or more spaces intended for charging electric vehicles. ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE). The conductors, including the ungrounded, grounded, and equipment grounding conductors and the electric vehicle connectors, attachment plugs, and all other fittings, devices, power outlets, or apparatus installed specifically for the purpose of transferring energy between the premises wiring and the electric vehicle. ENERGY EQUIVALENT (NOISE) LEVEL (Leq). The level of a steady noise which would have the same energy as the fluctuating noise level integrated over the time of period of interest. EXPRESSWAY. An arterial highway for through traffic which may have partial control of access, but which may or may not be divided or have grade separations at intersections. FREEWAY. A divided arterial highway with full control of access and with grade separations at intersections. GLOBAL WARMING POTENTIAL (GWP). The radiative forcing impact of one mass-based unit of a given greenhouse gas relative to an equivalent unit of carbon dioxide over a given period of time. Carbon dioxide is the reference compound with a GWP of one. GLOBAL WARMING POTENTIAL VALUE (GWP VALUE). A 100-year GWP value published by the Intergovernmental Panel on Climate Change (IPCC) in either its Second Assessment Report (SAR) (IPCC, 1995); or its Fourth Assessment A-3 Report (AR4) (IPCC, 2007). The SAR GWP values are found in column "SAR (100-yr)" of Table 2.14.; the AR4 GWP values are found in column "100 yr" of Table 2.14. HIGH-GWP REFRIGERANT. A compound used as a heat transfer fluid or gas that is: (a) a chlorofluorocarbon, a hdrochlorofluorocarbon, a hydrofluorocarbon, a perfluorocarbon, or any compound or blend of compounds, with a GWP value equal to or greater than 150, or (B) any ozone depleting substance as defined in Title 40 of the Code of Federal Regulations, Part 82, sec.82.3 (as amended March 10, 2009). LONG RADIUS ELBOW. Pipe fitting installed between two lengths of pipe or tubing to allow a change of direction, with a radius 1.5 times the pipe diameter. LOW-GWP REFRIGERANT. A compound used as a heat transfer fluid or gas that: (A) has a GWP value less than 150, and (B) is not an ozone depleting substance as defined in Title 40 of the Code of Federal Regulations, Part 82, sec.82.3 (as amended March 10, 2009). MERV. Filter minimum efficiency reporting value, based on ASHRAE 52.2–1999. MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base REactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundreths of a gram (g O3/g ROC). PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). PSIG. Pounds per square inch, guage. REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. SCHRADER ACCESS VALVES. Access fittings with a valve core installed. SHORT RADIUS ELBOW. Pipe fitting installed between two lengths of pipe or tubing to allow a change of direction, with a radius 1.0 times the pipe diameter. SUPERMARKET. For the purposes of Section 5.508.2, a supermarket is any retail food facility with 8,000 square feet or more conditioned area, and that utilizes either refrigerated display cases, or walk-in coolers or freezers connected to remote compressor units or condensing units. VOC. A volatile organic compound broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a) . Note: Where specific regulations are cited from different agencies such as SCAQMD, ARB, etc., the VOC definition included in that specific regulation is the one that prevails for the specific measure in question. SECTION 5.503 FIREPLACES 5.503.1 FIREPLACES. Install only a direct-vent sealed-combustion gas or sealed wood-burning fireplace, or a sealed woodstove or pellet stove, and refer to residential requirements in the California Energy Code, Title 24, Part 6, Subchapter 7, Section 150. Woodstoves, pellet stoves and fireplaces shall comply with applicable local ordinances. 5.503.1.1 Woodstoves. Woodstoves and pellet stoves shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. SECTION 5.504 POLLUTANT CONTROL 5.504.1 TEMPORARY VENTILATION. The permanent HVAC system shall only be used during construction if necessary to condition the building or areas of addition or alteration within the required temperature range for material and equipment installation. If the HVAC system is used during construction, use return air filters with a Minimum Efficiency Reporting Value (MERV) of 8, based on ASHRAE 52.2-1999, or an average efficiency of 30% based on ASHRAE 52.1-1992 Replace all filters immediately prior to occupancy, or, if the building is occupied during alteration, at the conclusion of construction. 5.504.3 Covering of duct openings and protection of mechanical equipment during construction. At the time of rough installation and during storage on the construction site until final startup of the heating, cooling and ventilation equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheetmetal or other methods acceptable to the enforcing agency to reduce the amount of dust, water and debris which may enter the system. 5.410.2.1 Owner's or Owner Representative's Project Requirements (OPR). [N] The expectations and requirements of the building appropriate to its phase shall be documented before the design phase of the project begins. This documentation shall include the following: 1. Environmental and sustainability goals. 2. Building sustainable goals. 3. Indoor environmental quality requirements. 4. Project program, including facility functions and hours of operation, and need for after hours operation. 5. Equipment and systems expectations. 6. Building occupant and operation and maintenance (O&M) personnel expectations. 5.410.2.2 Basis of Design (BOD). [N] A written explanation of how the design of the building systems meets the OPR shall be completed at the design phase of the building project. The Basis of Design document shall cover the following systems: 1. Renewable energy systems. 2. Landscape irrigation systems. 3. Water reuse system. 5.410.2.3 Commissioning plan. [N] Prior to permit issuance a commissioning plan shall be completed to document how the project will be commissioned. The commissioning plan shall include the following: 1. General project information. 2. Commissioning goals. 3. Systems to be commissioned. Plans to test systems and components shall include: a. An explanation of the original design intent. b. Equipment and systems to be tested, including the extent of tests. c. Functions to be tested. d. Conditions under which the test shall be performed. e. Measurable criteria for acceptable performance. 4. Commissioning team information. 5. Commissioning process activities, schedules and responsibilities. Plans for the completion of commissioning shall be included. 5.410.2.4 Functional performance testing. [N] Functional performance tests shall demonstrate the correct installation and operation of each component, system and system-to-system interface in accordance with the approved plans and specifications. Functional performance testing reports shall contain information addressing each of the building components tested, the testing methods utilized, and include any readings and adjustments made. 5.410.2.6 Commissioning report. [N] A report of commissioning process activities undertaken through the design and construction phases of the building project shall be completed and provided to the owner or representative. 5.410.4 TESTING AND ADJUSTING. New buildings less than 10,000 square feet. Testing and adjusting of systems shall be required for new buildings less than 10,000 square feet or new systems to serve an addition or alteration subject to Section 303.1. 5.410.4.2 (Reserved) Note: For energy-related systems under the scope (Section 100) of the California Energy Code, including heating, ventilation, air conditioning (HVAC) systems and controls, indoor lighting system and controls, as well as water heating systems and controls, refer to California Energy Code Section 120.8 for commissioning requirements and Sections 120.5, 120.6, 130.4, and 140.9(b)3 for additional testing requirements of specific systems. 5.410.4.2 Systems. Develop a written plan of procedures for testing and adjusting systems. Systems to be included for testing and adjusting shall include at a minimum, as applicable to the project: 1. Renewable energy systems. 2. Landscape irrigation systems. 3. Water reuse systems. 5.410.4.3 Procedures. Perform testing and adjusting procedures in accordance with manufacturer's specifications and applicable standards on each system. 5.410.4.3.1 HVAC balancing. In addition to testing and adjusting, before a new space-conditioning system serving a building or space is operated for normal use, the system shall be balanced in accordance with the procedures defined by the Testing Adjusting and Balancing Bureau National Standards; the National Environmental Balancing Bureau Procedural Standards; Associated Air Balance Council National Standards or as approved by the enforcing agency. SECTION 5.303 INDOOR WATER USE 5.303.1 METERS. Separate submeters or metering devices shall be installed for the uses described in Sections 503.1.1 and 503.1.2. 5.303.1.1 Buildings in excess of 50,000 square feet. Separate submeters shall be installed as follows: 1. For each individual leased, rented or other tenant space within the building projected to consume more than 100 gal/day (380 L/day), including, but not limited to, spaces used for laundry or cleaners, restaurant or food service, medical or dental office, laboratory, or beauty salon or barber shop. SECTION 5.410 BUILDING MAINTENANCE AND OPERATIONS 5.410.1 RECYCLING BY OCCUPANTS. Provide readily accessible areas that serve the entire building and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waste, and metals or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code 42649.82 (a)(2)(A) et seq. shall also be exempt from the organic waste portion of this section. 5.410.1.1 Additions. All additions conducted within a 12-month period under single or multiple permits, resulting in an increase of 30% or more in floor area, shall provide recycling areas on site. Exception: Additions within a tenant space resulting in less than a 30% increase in the tenant space floor area. 5.410.1.2 Sample ordinance. Space allocation for recycling areas shall comply with Chapter 18, Part 3, Division 30 of the Public Resources Code. Chapter 18 is known as the California Solid Waste Reuse and Recycling Access Act of 1991 (Act). Note: A sample ordinance for use by local agencies may be found in Appendix A of the document at the CalRecycle’s web site. 5.410.2.5 Documentation and training. [N] A Systems Manual and Systems Operations Training are required, including Occupational Safety and Health Act (OSHA) requirements in California Code of Regulations (CCR), Title 8, Section 5142, and other related regulations. 5.410.2.5.1 Systems manual. [N] Documentation of the operational aspects of the building shall be completed within the systems manual and delivered to the building owner or representative. The systems manual shall include the following: 1. Site information, including facility description, history and current requirements. 2. Site contact information. 3. Basic operations and maintenance, including general site operating procedures, basic troubleshooting, recommended maintenance requirements, site events log. 4. Major systems. 5. Site equipment inventory and maintenance notes. 6. A copy of verifications required by the enforcing agency or this code. 7. Other resources and documentation, if applicable. 5.410.2.5.2 Systems operations training. [N] A program for training of the appropriate maintenance staff for each equipment type and/or system shall be developed and documented in the commissioning report and shall include the following: 1. System/equipment overview (what it is, what it does and with what other systems and/or equipment it interfaces). 2. Review and demonstration of servicing/preventive maintenance. 3. Review of the information in the Systems Manual. 4. Review of the record drawings on the system/equipment. 2. Where separate submeters for individual building tenants are unfeasible, for water supplied to the following subsystems: a. Makeup water for cooling towers where flow through is greater than 500 gpm (30 L/s). b. Makeup water for evaporative coolers greater than 6 gpm (0.04 L/s). c. Steam and hot water boilers with energy input more than 500,000 Btu/h (147 kW). 5.303.1.2 Excess consumption. A separate submeter or metering device shall be provided for any tenant within a new building or within an addition that is projected to consume more than 1,000 gal/day. SECTION 5.304 OUTDOOR WATER USE 5.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Nonresidential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. Notes: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code of Regulations, Title 23, Chapter 2.7, Division 2. 2. MWELO and supporting documents, including a water budget calculator, are available at: https://www.water.ca.gov/. 5.304.6 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. For public schools and community colleges, landscape projects as described in Sections 5.304.6.1 and 5.304.6.2 shall comply with the California Department of Water Resources Model Water Efficient Landscape Ordinance (MWELO) commencing with Section 490 of Chapter 2.7, Division 2, Title 23, California Code of Regulations, except that the evapotranspiration adjustment factor (ETAF) shall be 0.65 with an additional water allowance for special landscape areas (SLA) of 0.35. Exception: Any project with an aggregate landscape area of 2,500 square feet or less may comply with the prescriptive measures contained in Appendix D of the MWELO. 5.304.6.1 Newly constructed landscapes. New construction projects with an aggregate landscape area equal to or greater than 500 square feet. 5.304.6.2 Rehabilitated landscapes. Rehabilitated landscape projects with an aggregate landscape area equal to or greater than 1,200 square feet. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. 5.303.4 COMMERCIAL KITCHEN EQUIPMENT. 5.303.4.1 Food Waste Disposers. Disposers shall either modulate the use of water to no more than 1 gpm when the disposer is not in use (not actively grinding food waste/no-load) or shall automatically shut off after no more than 10 minutes of inactivity. Disposers shall use no more than 8 gpm of water. Note: This code section does not affect local jurisdiction authority to prohibit or require disposer installation. 5.303.5 AREAS OF ADDITION OR ALTERATION. For those occupancies within the authority of the California Building Standards Commission as specified in Section 103, the provisions of Section 5.303.3 and 5.303.4 shall apply to new fixtures in additions or areas of alteration to the building. 5.303.6 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code and in Chapter 6 of this code. Y N/A SECTION 5.402 DEFINITIONS 5.402.1 DEFINITIONS. The following terms are defined in Chapter 2 (and are included here for reference) ADJUST. To regulate fluid flow rate and air patterns at the terminal equipment, such as to reduce fan speed or adjust a damper. BALANCE. To proportion flows within the distribution system, including sub-mains, branches and terminals, according to design quantities. BUILDING COMMISSIONING. A systematic quality assurance process that spans the entire design and construction process, including verifying and documenting that building systems and components are planned, designed, installed, tested, operated and maintained to meet the owner’s project requirements. ORGANIC WASTE. Food waste, green waste, landscape and pruning wste, nonhazardous wood waste, and food soiled paper waste that is mixed in with food waste. TEST. A procedure to determine quantitative performance of a system or equipment SECTION 5.407 WATER RESISTANCE AND MOISTURE MANAGEMENT 5.407.1 WEATHER PROTECTION. Provide a weather-resistant exterior wall and foundation envelope as required by California Building Code Section 1402.2 (Weather Protection), manufacturer's installation instructions or local ordinance, whichever is more stringent. 5.407.2 MOISTURE CONTROL. Employ moisture control measures by the following methods. 5.407.2.1 Sprinklers. Design and maintain landscape irrigation systems to prevent spray on structures. 5.407.2.2 Entries and openings. Design exterior entries and/or openings subject to foot traffic or wind-driven rain to prevent water intrusion into buildings as follows: 5.407.2.2.1 Exterior door protection. Primary exterior entries shall be covered to prevent water intrusion by using nonabsorbent floor and wall finishes within at least 2 feet around and perpendicular to such openings plus at least one of the following: 1. An installed awning at least 4 feet in depth. 2. The door is protected by a roof overhang at least 4 feet in depth. 3. The door is recessed at least 4 feet. 4. Other methods which provide equivalent protection. 5.407.2.2.2 Flashing. Install flashings integrated with a drainage plane. 5.410.2 COMMISSIONING. [N] New buildings 10,000 square feet and over. For new buildings 10,000 square feet and over, building commissioning shall be included in the design and construction processes of the building project to verify that the building systems and components meet the owner’s or owner representative’s project requirements. Commissioning shall be performed in accordance with this section by trained personnel with experience on projects of comparable size and complexity. For I-occupancies that are not regulated by OSHPD or for I-occupancies and L-occupancies that are not regulated y the California Energy Code Section 100.0 Scope, all requirements in Sections 5.410.2 through 5.410.2.6 shall apply. Note: For energy-related systems under the scope (Section 100) of the California Energy Code, including heating, ventilation, air conditioning (HVAC) systems and controls, indoor lighting systems and controls, as well as water heating systems and controls, refer to California Energy Code Section 120.8 for commissioning requirements Commissioning requirements shall include: 1. Owner’s or Owner representative’s project requirements. 2. Basis of design. 3. Commissioning measures shown in the construction documents. 4. Commissioning plan. 5. Functional performance testing. 6. Documentation and training. 7. Commissioning report. Exceptions: 1. Unconditioned warehouses of any size. 2. Areas less than 10,000 square feet used for offices or other conditioned accessory spaces within unconditioned warehouses. 3. Tenant improvements less than 10,000 square feet as described in Section 303.1.1. 4. Open parking garages of any size, or open parking garage areas, of any size, within a structure. Note: For the purposes of this section, unconditioned shall mean a building, area, or room which does not provide heating and or air conditioning. Informational Notes: 1. IAS AC 476 is an accreditation criteria for organizations providing training and/or certification of commissioning personnel. AC 476 is available to the Authority Having Jurisdiction as a reference for qualifications of commissioning personnel. AC 476 des not certify individuals to conduct functional performance tests or to adjust and balance systems. 2. Functional performance testing for heating, ventilation, air conditioning systems and lighting controls must be performed in compliance with the California Energy Code. 5.410.4.4 Reporting. After completion of testing, adjusting and balancing, provide a final report of testing signed by the individual responsible for performing these services. 5.410.4.5 Operation and maintenance (O & M) manual. Provide the building owner or representative with detailed operating and maintenance instructions and copies of guaranties/warranties for each system. O & M instructions shall be consistent with OSHA requirements in CCR, Title 8, Section 5142, and other related regulations. 5.410.4.5.1 Inspections and reports. Include a copy of all inspection verifications and reports required by the enforcing agency. Y N/A Y N/A Y N/ARESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 5.303.3.4 Faucets and fountains. 5.303.3.4.1 Nonresidential Lavatory faucets. Lavatory faucets shall have a maximum flow rate of not more than 0.5 gallons per minute at 60 psi. 5.303.3.4.2 Kitchen faucets. Kitchen faucets shall have a maximum flow rate of not more than 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 5.303.3.4.3 Wash fountains. Wash fountains shall have a maximum flow rate of not more than1.8 gallons per minute/20 [rim space (inches) at 60 psi]. 5.303.3.4.4 Metering faucets. Metering faucets shall not deliver more than 0.20 gallons per cycle. 5.303.3.4.5 Metering faucets for wash fountains. Metering faucets for wash fountains shall have a maximum flow rate of not more than 0.20 gallons per minute/20 [rim space (inches) at 60 psi]. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 5.303.3.4.6 Pre-rinse spray value When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7), and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY:The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤1.00 Product Class 2 (> 5.0 ozf and ≤1.20 Product Class 3 (> 8.0 ozf)1.28 X X X X X X X X X X X X X X X X X X CONTRACTOR CONTRACTOR DOC. REF. DOC. REF. DOC. REF. DOC. REF. C-4 M-1 E-1 C-4 M-1 E-1 POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) ZACHARY D. HARRIS No. M28906 Exp. 6/30/24 M E C H A N I C A L 3 CSGBC G-3 EA ZDH TW NON-RESIDENTIAL CHECKLIST - II 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE NONRESIDENTIAL MANDATORY MEASURES, SHEET 2 (January 2023) Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) DOC. REF.=DOCUMENT REFERENCE DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 5.504.4.3 Paints and coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Coatings Suggested Control Measure, as shown in Table 5.504.4.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 5.504.4.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in Subsections 4.21, 4.36 and 4.37 of the 2007 California Air Resources Board Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 5.504.4.3 shall apply. 5.504.4.3.1 Aerosol Paints and coatings. Aerosol paints and coatings shall meet the PWMIR Limits for ROC in Section 94522(a)(3) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(c)(2) and (d)(2) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8 Rule 49. 5.504.4.4.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health,"Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,"Version 1.2, January 2017 (Emission testing method for California Specifications 01350). See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.4.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 5.504.4.1. 5.504.4.5 Composite wood products. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure (ATCM) for Composite Wood (17 CCR 93120 et seq.). Those materials not exempted under the ATCM must meet the specified emission limits, as shown in Table 5.504.4.5. 5.504.4.5.3 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269 or European 636 3S standards. 5. Other methods acceptable to the enforcing agency. TABLE 5.504.4.1 - ADHESIVE VOC LIMIT1,2 Less Water and Less Exempt Compounds in Grams per Liter ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVES 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168, www.arb.ca.gov/DRDB/SC/CURHTML/R1168.PDF TABLE 5.504.4.2 - SEALANT VOC LIMIT Less Water and Less Exempt Compounds in Grams per Liter SEALANTS CURRENT VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NONPOROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 NOTE: FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THESE TABLES, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 5.504.4.3 - CONT. GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY CURRENT VOC LIMIT SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH-TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS: CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. TABLE 5.504.4.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIFORNIA CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16 INCHES (8 MM). 5.508.2 Supermarket refrigerant leak reduction. New commercial refrigeration systems shall comply with the provisions of this section when installed in retail food stores 8,000 square feet or more conditioned area, and that utilize either refrigerated display cases, or walk-in coolers or freezers connected to remote compressor units or condensing units. The leak reduction measures apply to refrigeration systems containing high-global-warming potential (high-GWP) refrigerants with a GWP of 150 or greater. New refrigeration systems include both new facilities and the replacement of existing refrigeration systems in existing facilities. Exception: Refrigeration systems containing low-global warming potential (low-GWP) refrigerant with a GWP value less than 150 are not subject to this section. Low-GWP refrigerants are nonozone-depleting refrigerants that include ammonia, carbon dioxide (CO2), and potentially other refrigerants. 5.508.2.1 Refrigerant piping. Piping compliant with the California Mechanical Code shall be installed to be accessible for leak protection and repairs. Piping runs using threaded pipe, copper tubing with an outside diameter (OD) less than 1/4 inch, flared tubing connections and short radius elbows shall not be used in refrigerant systems except as noted below. 5.508.2.1.1 Threaded pipe. Threaded connections are permitted at the compressor rack. 5.508.2.1.2 Copper pipe. Copper tubing with an OD less than 1/4 inch may be used in systems with a refrigerant charge of 5 pounds or less. 5.508.2.1.2.1 Anchorage. One-fouth-inch OD tubing shall be securely clamped to a rigid base to keep vibration levels below 8 mils. 5.508.2.1.3 Flared tubing connections. Double-flared tubing connections may be used for pressure controls, valve pilot lines and oil. Exception: Single-flared tubing connections may be used with a multiring seal coated with industrial sealant suitable for use with refrigerants and tightened in accordance with manufacturer's recommendations. 5.508.2.1.4 Elbows. Short radius elbows are only permitted where space limitations prohibit use of long radius elbows. 5.508.2.2 Valves. Valves Valves and fittings shall comply with the California Mechanical Code and as follows. 5.508.2.2.1 Pressure relief valves. For vessels containing high-GWP refrigerant, a rupture disc shall be installed between the outlet of the vessel and the inlet of the pressure relief valve. 5.508.2.2.1.1 Pressure detection. A pressure gauge, pressure transducer or other device shall be installed in the space between the rupture disc and the relief valve inlet to indicate a disc rupture or discharge of the relief valve. 5.508.2.2.2 Access valves. Only Schrader access valves with a brass or steel body are permitted for use. 5.508.2.2.2.1 Valve caps. For systems with a refrigerant charge of 5 pounds or more, valve caps shall be brass or steel and not plastic. 5.508.2.2.2.2 Seal caps. If designed for it, the cap shall have a neoprene O-ring in place. 5.508.2.2.2.2.1 Chain tethers. Chain tethers to fit ovr the stem are required for valves designed to have seal caps. Exception: Valves with seal caps that are not removed from the valve during stem operation. 5.508.2.3 Refrigerated service cases. Refrigerated service cases holding food products containing vinegar and salt shall have evaporator coils of corrosion-resistant material, such as stainless steel; or be coated to prevent corrosion from these substances. 5.508.2.3.1 Coil coating. Consideration shall be given to the heat transfer efficiency of coil coating to maximize energy efficiency. 5.508.2.4 Refrigerant receivers. Refrigerant receivers with capacities greater than 200 pounds shall be fitted with a device tha indicates the level of refrigerant in the receiver. 5.508.2.5 Pressure testing. The system shall be pressure tested during installation prior to evacuation and charging. 5.508.2.5.1 Minimum pressure. The system shall be charged with regulated dry nitrogen and appropriate tracer gas to bring system pressure up to 300 psig minimum. 5.508.2.5.2 Leaks. Check the system for leaks, repair any leaks, and retest for pressure using the same gauge. 5.508.2.5.3 Allowable pressure change. The system shall stand, unaltered, for 24 hours with no more than a +/- one pound pressure change from 300 psig, measured with the same gauge. 5.508.2.6 Evacuation. The system shall be evacuated after pressure testing and prior to charging. 5.508.2.6.1 First vacuum. Pull a system vacuum down to at least 1000 microns (+/- 50 microns), and hold for 30 minutes. 5.508.2.6.2 Second vacuum. Pull a second system vacuum to a minimum of 500 microns and hold for 30 minutes. 5.508.2.6.3 Third vacuum. Pull a third vacuum down to a minimum of 300 microns, and hold for 24 hours with a maximum drift of 100 microns over a 24-hour period. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC-CG] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. SECTION 5.505 INDOOR MOISTURE CONTROL 5.505.1 INDOOR MOISTURE CONTROL. Buildings shall meet or exceed the provisions of California Building Code, CCR, Title 24, Part 2, Sections 1202 (Ventilation) and Chapter 14 (Exterior Walls). For additional measures, see Section 5.407.2 of this code. SECTION 5.506 INDOOR AIR QUALITY 5.506.1 OUTSIDE AIR DELIVERY. For mechanically or naturally ventilated spaces in buildings, meet the minimum requirements of Section 120.1 (Requirements For Ventilation) of the California Energy Code, or the applicable local code, whichever is more stringent, and Division 1, Chapter 4 of CCR, Title 8. 5.506.2 CARBON DIOXIDE (CO2) MONITORING. For buildings or additions equipped with demand control ventilation, CO2 sensors and ventilation controls shall be specified and installed in accordance with the requirements of the California Energy Code, Section 120(c)(4). 5.506.3 Carbon dioxide (CO2) monitoring in classrooms. (DSA-SS) Each public K-12 school classroom, as listed in Table 120.1-A of the California Energy Code, shall be equipped with a carbon dioxide monitor or sensor that meets the following requirements: 1.The monitor or sensor shall be permanently affixed in a tamper-proof manner in each classroom between 3 and 6 feet (914 mm and 1829 mm) above the floor and at least 5 feet (1524 mm) away from door and operable windows. 2.When the monitor or sensor is not integral to an Energy Management Control System (EMCS), the monitor or sensor shall display the carbon dioxide readings on the device. When the sensor is integral to an EMCS, the carbon dioxide readings shall be available to and regularly monitored by facility personnel. 3.A monitor shall provide notification though a visual indicator on the monitor when the carbon dioxide levels in the classroom have exceeded 1,100ppm. A sensor integral to an EMCS shall provide notification to facility personnel through a visual and/or audible indicator when the carbon dioxide levels in the classroom have exceeded 1,100ppm. 4.The monitor or sensor shall measure carbon dioxide levels at minimum 15- minute intervals and shall maintain a record of previous carbon dioxide measurements of not less than 30 days duration. 5.The monitor or sensor used to measure carbon dioxide levels shall have the capacity to measure carbon dioxide levels with a range of 400ppm to 2000ppm or greater. 6.The monitor or sensor shall be certified by the manufacturer to be accurate within 75ppm at 1,000ppm carbon dioxide concentration and shall be certified by the manufacturer to require calibration no more frequently than once every 5 years. SECTION 5.507 ENVIRONMENTAL COMFORT 5.507.4 ACOUSTICAL CONTROL. Employ building assemblies and components with Sound Transmission Class (STC) values determined in accordance with ASTM E 90 and ASTM E 413, or Outdoor-Indoor Sound Transmission Class (OITC) determined in accordance with ASTM E 1332, using either the prescriptive or performance method in Section 5.507.4.1 or 5.507.4.2. Exception: Buildings with few or no occupants or where occupants are not likely to be affected by exterior noise, as determined by the enforcement authority, such as factories, stadiums, storage, enclosed parking structures and utility buildings. Exception: [DSA-SS] For public schools and community colleges, the requirements of this section and all subsections apply only to new construction. 5.507.4.1 Exterior noise transmission, prescriptive method. Wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall meet a composite STC rating of at least 50 or a composite OITC rating of no less than 40, with exterior windows of a minimum STC of 40 or OITC of 30 in the following locations: 1. Within the 65 CNEL noise contour of an airport. Exceptions: 1. Ldn or CNEL for military airports shall be determined by the facility Air Installation Compatible Land Use Zone (AICUZ) plan. 2. Ldn or CNEL for other airports and heliports for which a land use plan has not been developed shall be determined by the local general plan noise element. 2. Within the 65 CNEL or Ldn noise contour of a freeway or expressway, railroad, industrial source or fixed-guideway source as determined by the Noise Element of the General Plan. 5.507.4.1.1. Noise exposure where noise contours are not readily available. Buildings exposed to a noise level of 65 dB Leq - 1-hr during any hour of operation shall have building, addition or alteration exterior wall and roof-ceiling assemblies exposed to the noise source meeting a composite STC rating of at least 45 (or OITC 35), with exterior windows of a minimum STC of 40 (or OITC 30). 5.507.4.2 Performance Method. For buildings located as defined in Section 5.507.4.1 or 5.507.4.1.1, wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall be constructed to provide an interior noise environment attributable to exterior sources that does not exceed an hourly equivalent noise level (Leq-1Hr) of 50 dBA in occupied areas during any hour of operation. 5.507.4.2.1 Site Features. Exterior features such as sound walls or earth berms may be utilized as appropriate to the building, addition or alteration project to mitigate sound migration to the interior. 5.507.4.2.2 Documentation of Compliance. An acoustical analysis documenting complying interior soundlevels shall be prepared by personnel approved by the architect or engineer of record. 5.507.4.3 Interior sound transmission. Wall and floor-ceiling assemblies separating tenant spaces and tenant spaces and public places shall have an STC of at least 40. Note: Examples of assemblies and their various STC ratings may be found at the California Office of Noise Control: www.toolbase.org/PDF/CaseStudies/stc_icc_ratings.pdf. SECTION 5.508 OUTDOOR AIR QUALITY 5.508.1 Ozone depletion and greenhouse gas reductions. Installations of HVAC, refrigeration and fire suppression equipment shall comply with Sections 5.508.1.1 and 5.508.1.2. 5.508.1.1 Chlorofluorocarbons (CFCs). Install HVAC, refrigeration and fire suppression equipment that do not contain CFCs. 5.508.1.2 Halons. Install HVAC, refrigeration and fire suppression equipment that do not contain Halons. 5.504.4.6 Resilient flooring systems. Where resilient flooring is installed, at least 80 percent of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health,"Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specifications 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.6.1 Verification of compliance. Documentation shall be provided verifying that resilient flooring materials meet the pollutant emission limits. 5.504.4.7 Thermal insulation Comply with the requirements of the California Department of Public Health, "Standard Method of the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, "Version 1.2, January 1.2, January 2017 (Emission testing method for California Specification 01350). See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4.7.1 Verification of compliance. Documentation shall be provided verifying that thermal insulation materials meet the pollutant emission limits. 5.504.4.8 Acoustical ceiling and wall panels. Comply with the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, " Version 1.2, January 2017 (Emission testing method for California Specification 01350). See California Department of Public Health's website for certification programs and testing labs. 5.504.4.8.1 Verification of compliance. Documentation shall be provided verifying that acoustical finish materials meet the pollutant emission limits. 5.504.5.3 Filters. In mechanically ventilated buildings, provide regularly occupied areas of the building with air filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value (MERV) of 13. MERV 13 filters shall be installed prior to occupancy, and recommendations for maintenance with filters of the same value shall be included in the operation and maintenance manual. Exceptions: Existing mechanical equipment. 5.504.5.3.1 Labeling. Installed filters shall be clearly labeled by the manufacturer indicating the MERV rating. 5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. Where outdoor areas are provided for smoking, prohibit smoking within 25 feet of building entries, outdoor air intakes and operable windows and within the building as already prohibited by other laws or regulations; or as enforced by ordinances, regulations or policies of any city, county, city and county, California Community College, campus of the California State University, or campus of the University of California, whichever are more stringent. When ordinances, regulations or policies are not in place, post signage to inform building occupants of the prohibitions. 5.504.4.3.2 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification 2. Field verification of on-site product containers 5.504.4.4 Carpet Systems. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." Version 1.2, January 2017 (Emission testing method for California Specifications 01350). See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx#material 5.504.4 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with Sections 5.504.4.1 through 5.504.4.6. 5.504.4.1 Adhesives, sealants and caulks. Adhesives, sealants, and caulks used on the project shall meet the requirements of the following standards: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable, or SCAQMD Rule 1168 VOC limits, as shown in Tables 5.504.4.1 and 5.504.4.2. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and trichloroethylene), except for aerosol products as specified in subsection 2, below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than one pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with Section 94507. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/A Y N/A Y N/A Y N/ARESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY X X X X X X X X X CONTRACTOR ENGINEER DOC. REF. DOC. REF. DOC. REF. DOC. REF. M-1 E-1 M-1 POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) ZACHARY D. HARRIS No. M28906 Exp. 6/30/24 M E C H A N I C A L 4 CSGBC G-4 EA ZDH TW NON-RESIDENTIAL CHECKLIST - III 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE NONRESIDENTIAL MANDATORY MEASURES, SHEET 3 (January 2023) Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) DOC. REF.=DOCUMENT REFERENCE DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 ABBREVIATIONS CIVIL NOTES GENERAL 1.OBTAIN PERMITS NECESSARY TO COMPLETE FEATURES WITHIN EASEMENTS, DEDICATIONS AND PUBLIC RIGHT-OF-WAY. 2.NOT USED 3.ORIENT SURFACE FEATURES PARALLEL TO CURB/GUTTER OR WALLS UNLESS OTHERWISE NOTED. 4.PROTECT ALL SURVEY MONUMENTS. 5.SHOULD THE CONTRACTOR DISCOVER ANY DISCREPANCIES BETWEEN THE CONDITIONS EXISTING IN THE FIELD AND THE INFORMATION SHOWN ON THESE DRAWINGS, CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO PROCEEDING WITH CONSTRUCTION. 6.THE CONTRACTOR SHALL MAINTAIN A COPY OF AN APPROVED SET OF PLANS ON THE CONSTRUCTION SITE AT ALL TIMES. 7.NOT USED. 8.NOT USED. 9."LIMITS OF WORK" INDICATES THE TOTAL AREA OF DISTURBANCE DUE TO THE NATURE AND SCOPE OF THE WORK. THE TERM MAY ALSO BE USED TO INDICATE AREAS WHERE ACCESS IS LIMITED OR RESTRICTED. 10.PROVIDE TEMPORARY TRAFFIC SIGNAGE IN ACCORDANCE WITH STATE AND LOCAL AGENCIES DURING THE COURSE OF CONSTRUCTION. 11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL WITHIN THE PUBLIC RIGHT OF WAY IN ACCORDANCE WITH LOCAL ORDINANCES. NO WORK SHALL COMMENCE UNTIL ALL REQUIRED TRAFFIC CONTROL MEASURES ARE IN PLACE. LC PL +- FOOT, FEET INCH, INCHES POUND, NUMBER PERCENT AND AT APPROXIMATELY CENTERLINE PLATE LESS THAN EQUALS GREATER THAN DEFLECTION ANGLE DEGREE(-S) (ANGULAR) AMERICAN ASSOCIATION OF STATE HIGHWAY TRANSPORTATION OFFICIALS AGGREGATE BASE, ANCHOR BOLT(-S) ABANDON(-ED) ACRYLONITRILE-BUTADIENE-STYRENE ASPHALTIC CONCRETE ASBESTOS CEMENT PIPE AMERICANS WITH DISABILITIES ACT ADDITIONAL ADJUST(-ED,-MENT,-ABLE) AVERAGE DRY WEATHER FLOW ACRE-FEET AGGREGATE ALTITUDE ALUMINUM ANCHOR APPROXIMATE(-LY) ARCHITECT(-URAL) AMERICAN SOCIETY OF CIVIL ENGINEERS ASPHALT ASSEMBLY AMERICAN SOCIETY FOR TESTING AND MATERIALS AVENUE AVERAGE ADVANCED WATER TREATMENT AMERICAN WATER WORKS ASSOCIATION BOTTOM OF WALL BEGINNING OF HORIZONTAL CURVE BEGIN CURB RETURN BLIND FLANGE BACKFLOW PREVENTER BUILDING BLOCK(-S) BENCH MARK BLOWOFF BACK OF CURB BOTTOM BEGINNING OF VERTICAL CURVE CURVE CENTER-TO-CENTER CALCULATION(S) CABLE TV CATCH BASIN CEMENT CUBIC FEET PER SECOND CHANNEL CAST IRON CAST IRON PIPE CAST IRON SOIL PIPE CONSTRUCTION JOINT CLEAR(-ANCE) CONTROLLED LOW STRENGTH MATERIAL CEMENT MORTAR COATED CEMENT MORTAR LINED CEMENT MORTAR LINED AND COATED CORRUGATED METAL PIPE CONCRETE MASONRY UNIT CONTROL JOINT CENTER CLEANOUT COLUMN CONCRETE CONNECT (-ED, -S, -ION) CONSTRUCTION CONTINU(-ED, -OUS, -ATION) CORPORATION CLEANOUT TO GRADE CONTROL POINT, CATHODIC PROTECTION COUPLING CHLORINTATED POLYVINYL CHLORIDE CRUSHED ROCK CONTROL CATHODIC TEST STATION CUBIC FOOT, CUBIC FEET CUBIC YARD(-S) DOUBLE CHECK ASSEMBLY (TWIN ELEMENT CHECK VALVE) DEFLECTION DEGREE(-S) DEMOLISH DEPARTMENT DUCTILE IRON, DROP INLET DIAMETER DIAGONAL DIAPHRAGM DIMENSION(-S) DUCTILE IRON PIPE DISCHARGE DISTRIBUTION DEAD LOAD DOWN DISSOLVED OXYGEN ' " # % & @ < = > ∆ ∠ ° AASHTO AB ABAN(-D) ABS AC ACP ADA ADDIT ADJ ADWF AF AGG ALTD ALUM ANC APPROX ARCH ASCE ASPH ASSY ASTM AVE AVG AWT AWWA B/W BC BCR BF BFP BLDG BLK BM BO BOC BOT BVC C C/C CALC(S) CATV CB CEM CFS CHAN CI CIP CISP CJ CLR CLSM CMC CML CML&C CMP CMU CNJ CNTR CO COL CONC CONN CONST CONT CORP COTG CP CPLG CPVC CR CTRL CTS CU FT CU YD DCA DEFL DEG DEMO DEPT DI DIA DIAG DIAPH DIM(-S) DIP DISCH DISTR DL DN DO DRAIN DOWN SPOUT DETAIL(-S) DRAWING(-S) EAST EACH END OF HORIZONTAL CURVE ECCENTRIC EPOXY COATED END CURB RETURN EACH FACE EFFICIENCY EFFLUENT EXISTING GRADE ENERGY GRADE LINE ELEVATION, EPOXY LINED EPOXY LINED AND COATED ELECTRIC(-AL) ELBOW EMERGENCY ENCLOSURE ENGINEER EDGE OF PAVEMENT ENVIRONMENTAL PROTECTION AGENCY EQUAL (-LY, -IZATION) EQUIPMENT ESTIMATE(-D) ET CETERA ELECTROLYSIS TEST STATION END OF VERTICAL CURVE EACH WAY EXCAVATE EXHAUST EXISTING EXPANSION EXTERNAL FACTORY FACILIT(-Y, -IES) FLEXIBLE COUPLING FLANGE COUPLING ADAPTER FLOOR CLEANOUT FLOOR DRAIN FEEDER FINISHED FLOOR FINISHED FLOOR ELEVATION FINISHED GRADE FIRE HYDRANT FIGURE FINISH(-ED) FLOW LINE FLEXIBLE FLANGE(-D) FLOCCULATION FLOOR FLOW METER FIBER OPTIC FEET PER SECOND FIBERGLASS REINFORCED PLASTIC FINISHED SURFACE FOOT, FEET FOOTING FUTURE GAUGE GRANULAR ACTIVATED CARBON GALLON(-S) GALVANIZED GASOLINE GRADE BREAK GALVANIZED IRON GROUND GALLONS PER DAY GALLONS PER HOUR GALLONS PER MINUTE GROUND-PENETRATING RADAR GRATE GUARDRAIL GALVANIZED STEEL HIGH, HEIGHT HYDROGEN PEROXIDE HYDROGEN SULFIDE SULFURIC ACID HOSE BIB HIGH DENSITY POLYETHYLENE HYDRAULIC GRADE LINE HANDHOLE HOLLOW METAL HORIZONTAL HORSEPOWER HINGE POINT HIGH POINT HOUR(-S) HEIGHT HEATING, VENTILATING, AND AIR CONDITIONING HIGH WATER LEVEL HIGHWAY HYDRAULIC INSTRUMENTATION AND CONTROL INSIDE DIAMETER INVERT ELEVATION INCH(-ES) INFLUENT INSTRUMENT(-ATION) INVERT IRON PIPE SIZE IRRIGATION ISOLAT(-E, -ION) DR DS DTL(-S) DWG(-S) E EA EC ECC ECD ECR EF EFFIC EFFL EG EGL EL EL&C ELEC ELL EMERG ENCL ENGR EP EPA EQ EQPM EST ETC ETS EVC EW EXC EXH EXIST EXP EXT FAC FACIL FC FCA FCO FD FDR FF FFE FG FH FIG FIN FL FLEX FLG FLOC FLR FM FO FPS FRP FS FT FTG FUT GA GAC GAL GALV GAS GB GI GND GPD GPH GPM GPR GR GRL GS H H2O2 H2S H2SO4 HB HDPE HGL HH HM HORZ HP H-P HPT HR(S) HT HVAC HWL HWY HYD I&C ID IE IN INFL INSTR INV IPS IRRG ISO ION EXCHANGE JUNCTION BOX JOINT LENGTH, LINE LATERAL POUND(-S) POUND(-S) PER SQUARE FOOT LINEAR FEET LONG LIP OF GUTTER LIVE LOAD LOCATION LOW POINT LIQUIFIED PETROLEUM GAS (PROPANE OR BUTANE AS NOTED) LONG RADIUS LEFT TURN LIGHTING LOW WATER LEVEL MAXIMUM MOTOR CONTROL CENTER MECHANICAL MICROFILTRATION MANUFACTURER MILLION GALLON(-S) MILLION GALLONS PER DAY MANHOLE ONE-THOUSANDTH OF AN INCH MINIMUM MISCELLANEOUS MECHANICAL JOINT MODIF(-Y, -ICATIONS) MONUMENT MILES PER HOUR MECHANICALLY STABILIZED EARTH MOUNT(-ED, -ING) METAL NORTH NOT APPLICABLE NORTH AMERICAN DATUM SODIUM HYPOCHLORITE SODIUM HYDROXIDE NORTH AMERICAN VERTICAL DATUM NORTHEAST NANOFILTRATION NOT FOR CONSTRUCTION NATURAL GAS AMMONIA NOT IN CONTRACT NUMBER NOMINAL NORMAL NATIONAL PIPE THREAD NOT TO SCALE NORTHWEST NORMAL WATER LEVEL OZONE ON CENTER OUTSIDE DIAMETER OVERFLOW ORIGINAL GROUND OPENING(-S) ORIGINAL PNEUMATIC, PIPE PROPERTY LINE PERFORATED ASBESTOS CEMENT PIPE PIECE(-S), PHOTOCELL, POINT OF CURVE (BEGIN CURVE) POINT OF COMPOUND CURVE PRETENSIONED CONCRETE CYLINDER PIPE PRESSURE CLEANOUT PRESSURIZED CLEANOUT TO GRADE POLYETHYLENE PERCOLAT(-E, -ION) PERFORAT(-E, -ED, -ES, -ATION) PROFILE POINT OF INTERSECTION PROJECT MANAGER POTABLE POWER POLE PAIR PRESSURE PROPERTY PROTECT(-OR) PRESSURE RELIEF VALVE, PRESSURE REDUCING VALVE POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PIPE SLEEVE PUMP STATION PRESSURE SUSTAINING VALVE POINT OF TANGENT (END CURVE), PRESSURE-TREATED, POINT(-S) POLYVINYL CHLORIDE, POINT OF VERTICAL CURVE POINT OF VERTICAL INTERSECTION PAVEMENT POINT OF VERTICAL TANGENCY POTABLE WATER POWER PEAK WET WEATHER FLOW RADIUS RIGHT OF WAY REINFORCED CONCRETE CYLINDER PIPE REINFORCED CONCRETE PIPE ROAD REDUCE(-R) IX JB JT L LAT LB(-S) LB(-S)/SF LF LG LIP LL LOC LP LPG LR LT LTG LWL MAX MCC MECH MF MFR MG MGD MH MIL(-S) MIN MISC MJ MOD(-S) MON MPH MSE MT(-D, -G) MTL N N/A NAD NAOCL NAOH NAVD NE NF NFC NG NH3 NIC NO NOM NORM NPT NTS NW NWL O3 OC OD OF OG OPNG(-S) ORIG P P/L PACP PC(-S) PCC PCCP PCO PCOTG PE PERC PERF PF PI PM POT PP PR PRESS PROP PROT PRV PSF PSI PSL PSTA PSV PT(-S) PVC PVI PVMT PVT PW PWR PWWF R, RAD R/W RCCP RCP RD RED REGULAT(-E, -OR, -ION, -ING) REINFORC(-E, -ED, -ING, -EMENT) REQUIRED REQUIREMENT RESILIENT RESERVOIR ROOM ROUND REVERSE OSMOSIS REDUCED PRESSURE PRINCIPLE RAILROAD RIGHT TURN ROUTE RETURN SEWER, SOUTH SIDEWALK SUPERVISORY CONTROL AND DATA ACQUISITION SCHEDULE STORM DRAIN STORM DRAIN MANHOLE SOUTHEAST SECTION SIGNAL SHEET SIDE INLET SIMILAR SPACE(-S, -D) SPECIFICATION(-S) SQUARE SQUARE FEET SQUARE MILES STAINLESS STEEL, SANITARY SEWER STREET STATION STANDARD(-S) STEEL STEAM STRUCTUR(-E, -AL) SUPPORT(-S) SURFACE SOUTHWEST SYMMETRICAL SYSTEM TOP AND BOTTOM TOP OF CONCRETE TOP OF PAVEMENT TOP OF STEEL TOP OF WALL TYPE ______ PIPE TYPE ______ SUPPORT TANGENT(-IAL) TEMPORARY BENCHMARK, TUNNEL BORING MACHINE TOTAL DYNAMIC HEAD TELEPHONE TEMPERATURE, TEMPORARY THICK(-ENED, -ENER, -NESS) THROUGH TANK TOPOGRAPHY TOTAL, TOTALIZE(R) TEST PIT TREATMENT TYPICAL UNDERDRAIN ULTRAFILTRATION UNDERGROUND UNKNOWN ULTRAVIOLET VARIES, VARIABLE VERTICAL CURVE VITRIFIED CLAY PIPE VERTICAL VARIABLE FREQUENCY DRIVE (AC) VERIFY IN FIELD VOLUME VERTICAL POINT OF INTERSECTION VENT VERTICAL TURBINE PUMP VENT TO ROOF WIDE, WIDTH, WELDED, WEST WITH WITHOUT WATER BAR WALL CLEANOUT WOOD WATER MANHOLE WATERPROOF WATER SURFACE WELDED STEEL PIPE WATERSTOP WEIGHT WATER TREATMENT PLANT WATER WATER VALVE WASTEWATER WELDED WIRE FABRIC WELDED WIRE MESH WASTEWATER TREATMENT PLANT TRANSFORMER YARD YEAR REG REINF REQD REQT RESIL RESV RM RND RO RPP RR RT RTE RTN S S/W SCADA SCH SD SDMH SE SECT SGNL SHT SI SIM SPC(-S, -D) SPEC(-S) SQ SQ FT SQ MI SS ST STA STD(-S) STL STM STRC SUPP SURF SW SYM SYS T&B T/C T/P T/S T/W T-_-P T-_-S TAN TBM TDH TEL TEMP THK THRU TNK TOPO TOT TP TRTMT TYP UD UF UG UNKN UV VAR VC VCP VERT VFD VIF VOL VPI VT VTP VTR W W/ W/O WB WCO WD WMH WP WS WSP WSTP WT WTP WTR WV WW WWF WWM WWTP XFMR YD YR RECORD DRAWING REFERENCE NOTES SITE FEATURES AND UTILITIES SHOWN ON SHEET C-1, C-4, AND C-5 WERE TRACED FROM RECORD DRAWINGS (ASBUILT FOR "CONSTRUCTION PLANS FOR POINSETTIA SEWAGE LIFT STATION UPGRADE" DATED MAY 2007, AND APPROVED ON 6-14-07) AND SUPPLEMENTED WITH INFORMATION FROM RECORD DRAWINGS (ASBUILT FOR "PLANS FOR THE CONSTRUCTION OF THE POINSETTIA SEWAGE LIFT STATION IN THE CARLSBAD MUNICIPAL WATER DISTRICT" AS-BUILT DATED 6/18/99). SURFACE FEATURES AND UTILITIES PROVIDED AS REFERENCE FOR CONSTRUCTION ALL LOCATIONS TO BE FIELD VERIFIED. SPOT ELEVATIONS SHOWN ON C-5 WERE TRACED FROM RECORD DRAWINGS (ASBUILT FOR "PLANS FOR THE CONSTRUCTION OF THE POINSETTIA SEWAGE LIFT STATION IN THE CARLSBAD MUNICIPAL WATER DISTRICT" AS-BUILT DATED 6/18/99). CONTOUR SHOWN ON SHEET C-5 WERE TRACED FROM RECORD DRAWINGS (ASBUILT FOR "CONSTRUCTION PLANS FOR POINSETTIA SEWAGE LIFT STATION UPGRADE DATED MAY 2007, AND APPROVED ON 6-14-07) CONTAINING THE FOLLOWING SOURCE OF TOPOGRAPHY. CONTOURS PROVIDED AS REFERENCE FOR CONSTRUCTION ALL ELEVATIONS TO BE FIELD VERIFIED. PIPING 1.THESE NOTES ARE GENERIC IN NATURE. PROJECT SPECIFIC NOTES ON FOLLOWING DRAWINGS TAKE PRECEDENCE. 2.THE CONTRACTOR SHALL COMPLY WITH THE STATE DEPARTMENT OF HEALTH SERVICES CRITERIA FOR THE SEPARATION BETWEEN WATER MAINS, NON-POTABLE WATER UTILITIES, AND SEWER. 3.INSTALL WATER, STORM, AND SEWER PIPELINES WITH A MINIMUM OF 36 INCHES OF COVER, UNLESS OTHERWISE NOTED. 4.PRIOR TO SUBMITTAL OF PIPE SHOP DRAWINGS, VERIFY THE INVERT ELEVATIONS, ALIGNMENT, OUTSIDE DIAMETER, LOCATION, AND MATERIAL OF ALL EXISTING PIPELINES TO WHICH NEW PIPELINES WILL BE CONNECTED. 5.PIPE STATIONING REPRESENTS THE HORIZONTAL PROJECTION OF THE PIPE CENTERLINE BETWEEN MANHOLES, POINTS OF INFLECTION, AND/OR CENTER OF FITTINGS. 6.RESTRAIN ALL PIPE, FITTINGS, FLEXIBLE CONNECTORS, AND/OR FLANGED COUPLING ADAPTERS UNLESS OTHERWISE NOTED. THRUST PROTECTION SHALL BE ADEQUATE FOR TEST PRESSURES SPECIFIED. 7.LOCATION OF EXISTING UTILITIES ARE APPROXIMATE. CONTRACTOR SHALL EXPOSE EXISTING PIPE(S) OR STRUCTURE(S) TO WHICH NEW PIPE(S) IS/ARE CONNECTING. VERIFY EXACT LOCATION, SIZE, MATERIALS, AND INVERT ELEVATIONS PRIOR TO SUBMITTING PIPE DRAWINGS. 8.PROTECT EXISTING UTILITIES UNLESS OTHERWISE NOTED. 9.USE CAUTION WHEN WORKING IN PROXIMITY TO GAS. NOTIFY UTILITY COMPANY WHEN WORKING WITHIN THE VICINITY, AND FOLLOW UTILITY SAFETY GUIDELINES AND OSHA REQUIREMENTS. HAND DIG ALL CONSTRUCTION WITHIN 5 FEET HORIZONTALLY OF ANY GAS MAIN. 10.USE CAUTION WHEN WORKING IN PROXIMITY TO OVERHEAD ELECTRICAL LINES. FOLLOW ELECTRICAL UTILITY SAFETY GUIDELINES AND OSHA REQUIREMENTS. 11.CROSSING PIPELINES SHOWN IN PROFILE REPRESENT OUTSIDE DIAMETER UNLESS OTHERWISE NOTED. 12.ORIENT ECCENTRIC MANHOLE(S) SUCH THAT THE LID IS OUTSIDE OF WHEEL PATH. 13.COORDINATES LOCATING MANHOLES ARE TO THE CENTER OF THE STRUCTURE. 14.SIZE OF FITTING SHOWN ON THE DRAWINGS CORRESPONDS TO THE ADJACENT STRAIGHT RUN OF PIPE, UNLESS OTHERWISE NOTED. MATCH TYPE OF JOINT AND FITTING MATERIAL TO ADJACENT STRAIGHT RUN OF PIPE, UNLESS OTHERWISE NOTED. 15.PIPE HANGER AND SUPPORT LOCATIONS SHOWN ARE APPROXIMATE. FINAL PIPE SUPPORT LOCATIONS SHALL BE SUBMITTED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER PRIOR TO INSTALLATION. 16.NUMBER AND LOCATION OF UNIONS SHOWN ON DRAWINGS ARE APPROXIMATE. PROVIDE UNIONS NECESSARY TO FACILITATE CONVENIENT REMOVAL OF VALVES AND MECHANICAL EQUIPMENT. 17.COORDINATE AND PERFORM CONNECTIONS TO THE WORK OF OTHER CONTRACTORS, IF APPLICABLE. GRADING 1.ADJUST VALVE BOXES, PULL BOXES, VAULTS, AND MAHOLES TO FINISHED GRADES AND SLOPES SHOWN ON CIVIL GRADING DRAWINGS UNLESS OTHERWISE SHOWN OR SPECIFIED. MANHOLES IN OPEN FIELDS SHALL BE SET ONE FOOT ABOVE GRADE. APPROXIMATE RIM ELEVATIONS ARE SHOWN ON DRAWINGS. 2.GRADES SHOWN ARE TO TOP OF THE FINISHED SURFACE UNLESS OTHERWISE NOTED. DEMOLITION 1.DEMOLITION EXTENTS INDICATED IN DRAWINGS ARE THE MINIMUM REQUIRED TO COMPLETE THE WORK. EXTENTS OF DEMOLITION REFLECTED IN THE CONTRACTOR'S BID SHALL INCORPORATE DEMOLITION MEANS AND METHODS. 2.PROVIDE COORDINATES OF ABANDONED UTILITIES IN THE RECORD DRAWINGS. POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) JOSE A. CUEVAS No. C63541 Exp. 9/30/24 C I V I L Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 7 P M 5 CIVIL ABBREVIATIONS AND NOTES C-1 EA JC PT DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 CORROSION CONTROL SYMBOLS EROSION CONTROL SYMBOLS EXISTING FEATURES PIPING AND UTILITIESTOPOGRAPHY AND MAPPING SYMBOLSGEOTECHNICAL SYMBOLS ROADWORK AND PAVING STRUCTURES SLOPE ON PAVED SURFACE OR PIPE BERM SLOPE (HORZ TO VERT) S=0.012 3:1 P/L P/L R/W R/W 125 MAJOR CONTOURS MINOR CONTOURS TOP OF SLOPE TOE OF SLOPE PROPERTY LINE RIGHT-OF-WAY LINE GRADE BREAK RIDGE LINE EASEMENT LINE TEMPORARY EASEMENT LINE R ESMT ESMT TRAIL OR DIRT ROAD FLOW LINE FLOOD HAZARD AREA EDGE OF WETLANDS RAILROAD GUARDRAIL (PERMANENT) VEGETATION WELL G BLOWOFF (IN PLAN) LOCATE ON SIDE SHOWN BLOWOFF (IN PROFILE) FIRE HYDRANT (IN PLAN) MH MANHOLE (IN PLAN) CLEANOUT TO GRADE (IN PLAN) SOIL BORING LOCATION TEST PIT LOCATION MONITORING WELL RIPRAP HAY BALE/STRAW WATTLE SILT FENCE ELECTROLYSIS TEST STATION CATHODIC TEST STATION CATS IJTS FPTS CSTS CORROSION TEST STATION CASING TEST STATION INSULATING JOINT TEST STATION FOREIGN PIPELINE TEST STATION CURRENT SPAN TEST STATION FENCE (CHAIN LINK) FENCE (WOOD) STRUCTURE STRUCTURE (BELOW GRADE) BENCH MARK SITE COORDINATES (SEE TABLE ON DRAWINGS) SITE COORDINATESN XXXXXX.XX E XXXXXX.XX CONTROL POINT FINISHED ELEVATION/GRADE EXISTING ELEVATION/GRADE ASPHALT (IN PLAN AND SECTION) CONCRETE CURB CONCRETE CURB AND GUTTER DRIVEWAY/ACCESS RAMP GENERAL CIVIL SYMBOLS DROP INLET CATCH BASIN NOTES: 1.PAVING PATTERNS MAY ONLY APPEAR IN PORTIONS OF PAVED AREAS TO DEFINE LIMITS OF PAVING. 2.SEE ALSO GENERAL LEGEND FOR ADDITIONAL PAVING PATTERNS. AV/AR VALVE (IN PLAN) LOCATE ON SIDE SHOWN AV/AR VALVE (IN PROFILE) POWER POLE FG XXX.XX EG XXX.X TEMPORARY NATURAL GAS GUY LINE AND ANCHOR MONUMENT SITE OR RETAINING WALL PROTECTIVE BARRIER PROTECTIVE BARRIER (REMOVABLE) EXISTING UTILITIES FENCE (SWING GATE) 124 LIMITS OF EXCAVATION CONTROL SYMBOLS TREE (SIZE AND TYPE) HPG HIGH PRESSURE GAS LPG LIQUID PETROLEUM W WATER LINE PW POTABLE WATER FIRE FIRE SUPPLY WATER REW RECLAIMED WATER UW UTILITY/NON-POTABLE WATER IRR IRRIGATION WATER SDR STORM DRAIN SS SANITARY SEWER STM STEAM TEL TELEPHONE COMM COMMUNICATIONS LINE FOC FIBER OPTIC CABLE CATV CABLE TV E POWER UNK UNIDENTIFIED ABND ABANDONED UTILITY M B T C HR W BFP BM-XX # CTS T CO ETSETS FH TP-# MW CO MAILBOX TRAFFIC SIGNAL BOX OR POLE SIGN TELEPHONE BOX COMMUNICATION/CATV BOX HOSE BIBB HOSE RACK WATER BOX/METER BACKFLOW PREVENTER # WELDED WIRE FABRIC (IN SECTION) CURVE DATA (SEE TABLE ON DRAWINGS)X PROPOSED FEATURES +-LIMITS OF GRADING LID FLARED END SECTION MH LID MH LID MANHOLE OR VAULT FH FIRE HYDRANT SURFACE FLOW DIRECTION DESCRIPTION POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) JOSE A. CUEVAS No. C63541 Exp. 9/30/24 C I V I L Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 7 P M 6 CIVIL LEGEND C-2 EA JC PT DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 ESMT ESMT ESM T ESMT ESMT ESMT ESMT ESMT ESMT ESMT ESMT ESMT ESM T ESMT ESMT ESMT ESMT P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/L POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) JOSE A. CUEVAS No. C63541 Exp. 9/30/24 C I V I L Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 8 P M 7 C-3 EA JC PT SITE PLAN GENERATOR / CHEMICAL STORAGE BUILDING CONTROL /PUMP BUILDING ODOR CONTROL SYSTEM POINSE T T I A L A N E 4' DIAMETER SURGE TANK EDGE OF PAVEMENT 25'± AC ACC E S S ROAD GATE GATE 22'± AC ACCESS R O A D MANHOLE (TYP) PROPERTY LINE 20 ' V A L L E C I T O S WA T E R D I S T R I C T EA S T M E N T FLOW METER AND EMERGENCY BYPASS CONNECTION VAULT LOCAL CONTROL POINT 19'x8' TRAILER MOUNTED BYPASS PUMP SECONDARY BYPASS LINE CONNECTION BOLLARDS (TYP) FENCE (TYP) CIVIL PROJECT AREA SEE SHEETS C-4 AND C-5 SWALE 0 1"=10' 10 20 TRANSFORMER PAD OVERALL SITE PLAN AND KEY MAP APPROXIMATE SQ FT: 1272 APPROXIMATE SQ FT: 1788 SEE NOTE 1 SEE NOTE 1 1.POTENTIAL CONTRACTOR STAGING AREAS. TO BE COORDINATED WITH CITY PRIOR TO USE. PROTECT ALL EXIST. ITEMS ADJACENT TO CONTRACTOR STAGING AREAS. GENERAL SHEET NOTES DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 P/L P/L P/L P/L P/L UW UW UW UW W W W W PW PW PW PW PW PW P/L P/L P/L P/L P/L POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) JOSE A. CUEVAS No. C63541 Exp. 9/30/24 C I V I L Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 8 P M 8 CIVIL DEMO AND SITE PLAN C-4 EA JC PT DEMO PLAN GENERATOR / CHEMICAL STORAGE BUILDING CONTROL /PUMP BUILDING 16" A I R P I P I N G 8" A I R P I P I N G 4" PV C D R A I N P I P E 1" CO P P E R P L A N T W A T E R L I N E 1/2" S C H 8 0 P V C C H E M I C A L F E E D P I P I N G 1-1/4 " C O P P E R P O T A B L E W A T E R L I N E 12" D . I . P . F O R C E M A I N COND U I T S ODOR CONTROL SYSTEM SITE PLAN GENERATOR / CHEMICAL STORAGE BUILDING ODOR CONTROL SYSTEM1" P W PROTECT CONCRETE SWALE PROTECT 16" AIR PIPING TOP 102.97 PROTECT 1" RISERS, WALL MOUNTED HOSE RACK AND HOSE BIBB SAWCUT AND REMOVE AC PAVEMENT AND BASE FOR NEW DUCT AND PAD 5'-2 " 21' - 1 " 4'-2" 26 ' - 3 " 5'-2 " BEGIN DEMO 1" PLANT WATER END DEMO OF 1" PLANT WATER 0 1"=5' 5 10 0 1"=5' 5 10 4'-2 " 26 ' - 9 " 3'-0" 2'-0" JO I N E X I S T JO I N E X I S T ASPHALT PAVING MATCH EXIST AC THICKNESS AND BASE THICKNESS 5'-2 " 3'-6" CONDUIT S 2'-0 " B PROTECT CONDUITS A DEMO PORTION OF WALL MOUNTED DOWNSPOUT PROTECT 8" AIR PIPING PROTECT CONDUITS C-6 1 E-10 1 C-6 2 C-6 3 DOOR MODIFICATION DOWNSPOUT 6"MANUAL TRANSFER SWITCH (MTS) PAD SHEET KEYNOTES A.REMOVE AND SALVAGE WALL MOUNTED DOOR STOP. RETURN TO OWNER B.IF REQUIRED, REMOVE 1" PLANT WATER FOR INSTALLATION OF ELEC DUCT. PROTECT 1" RISER TO WALL MOUNTED HOSE RACK DURING CONSTRUCTION. 1.CONSTRUCTION AND DEMOLITION OPERATIONS SHALL INCORPORATE SALVAGE AND/OR RECYCLING OF MATERIALS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, AS ADOPTED BY THE CITY OF CARLSBAD. GENERAL SHEET NOTES DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 P/L P/L P/L P/L P/L UW UW UW UW W W W W PW PW PW PW PW PW P/L P/L P/L P/L P/L 106.5 106 POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) JOSE A. CUEVAS No. C63541 Exp. 9/30/24 C I V I L Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 8 P M 9 CIVIL GRADING AND UTILITY PLAN C-5 EA JC PT UTILITY PLAN GENERATOR / CHEMICAL STORAGE BUILDING 16" A I R P I P I N G 8" A I R P I P I N G 4" PV C D R A I N P I P E 1" CO P P E R P L A N T W A T E R L I N E 1/2" S C H 8 0 P V C C H E M I C A L F E E D P I P I N G 1-1/4 " C O P P E R P O T A B L E W A T E R L I N E 12" D . I . P . F O R C E M A I N COND U I T S ODOR CONTROL SYSTEM GRADING PLAN GENERATOR / CHEMICAL STORAGE BUILDING FF=107.0 CONTROL /PUMP BUILDING ODOR CONTROL SYSTEM 1P W 106 106.86 106.51 FL 106.10 FL 106.23 FL 0 1"=5' 5 10 0 1"=5' 5 10 MANUAL TRANSFER SWITCH (MTS) PAD SEE NOTE 1 MATCH EXIST ELEV. MATCH EXIST ELEV 106.85 MATCH EXIST ELEV 106.79 5'-0" 1'-7" 3'-1"E-10 1 PROTECT 16" AIR PIPING TOP EL 102.97 1" COPPER PLANT WATER LINE INSTALL 4'-3" CONDUITS JOIN EXIST 1" PLANT WATER LINE W/ 45° BEND MATCH EXIST ELEV JOIN EXIST 1" PLANT WATER LINE W/ 1"x1"x1" TEE MATCH EXIST ELEV JOIN EXIST CONCRETE ENCASED DUCTBANK CONDUITS TOP OF DUCT ESTIMATED AT 104.0. FIELD VERIFY 7'-3 " MA T C H E X I S T 45° BEND MATCH EXIST ELEV 14' - 1 1 " PROTECT 8" AIR PIPING PROTECT CONDUITS CONDUITS MATCH EXIST ELEV. MATCH EXIST ELEV. 1'-3 " MA T C H E X I S T A 1.FIELD VERIFY EXIST GRADE AT PAD LOCATION. TOP OF PAD SHALL BE 2" ABOVE EXIST GRADE. SEE STRUCTURAL DETAIL S-3342 FOR PAD DETAIL. GENERAL SHEET NOTES SHEET KEYNOTES A.INSTALL REMOVED 1" PLANT WATER WITH REVISE ELEVATIONS AS REQUIRED TO AVOID CONFLICT WITH ELEC DUCT. RECONNED TO EXIST 1" RISER TO WALL MOUNTED HOSE RACK AND TO EXIST 1" PLANT WATER. DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 PROTECT HOSE RACK PROTECT VENT MATCH EXISTING REPLACE DOOR LABEL AS REQUIRED WITH SAME FONT AND DESCRIPTION DOOR JAMBS DOOR SWING DIRECTION DOORKNOB C-4 3 DOOR MODIFICATION DETAIL SCALE: NTS GENERATOR/CHEMICAL STORAGE BUILDING C-4 1 DOWNSPOUT DEMOLITION DETAIL SCALE: NTS GENERATOR/CHEMICAL STORAGE BUILDING C-4 2 DOWNSPOUT MODIFICATION DETAIL SCALE: NTS GENERATOR/CHEMICAL STORAGE BUILDING CLEANLY SAWCUT REMOVE DOWNSPOUT ANCHORS PROTECT UTILITIES AND BRACKETS PROTECT VENT JOIN TO REMAINING DOWN SPOUT INSTALL TRANSITION DOWNSPOUT PIECE INSTALL DOWNSPOUT AND ANCHORS TO BUILDING DOOR STOP SEE DEMO PLAN C-4 C A D B POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) JOSE A. CUEVAS No. C63541 Exp. 9/30/24 C I V I L Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 8 P M 10 CIVIL DETAILS C-6 EA JC PT 1.DOWNSPOUT AND DOOR TO MATCH EXISTING MATERIALS, FINISHES, AND PAINTED TO MATCH EXISTING. 2.PATCH ANY HOLES ON GENERATOR/CHEMICAL STORAGE BUILDING WITH CONCRETE TO MATCH EXISTING COLORS AND TEXTURE. 3.PROVIDE ATTACHMENTS TO BUILDING WALL AS REQUIRED. SEE STRUCTURAL SHEETS FOR ADDITIONAL NOTES. 4.UPON COMPLETION OF DOWNSPOUT INSTALLATION CONDUCT WATER FLOW TEST IN PRESENCE OF ENGINEER AND/OR OWNER TO ENSURE NO LEAKS ALONG DOWN SPOUTS ARE DETECTED. GENERAL SHEET NOTES A.REMOVE EXISTING RIGHT-HAND REVERSE DOOR, DOOR FRAME AND FINISH HARDWARE IN THEIR ENTIRETY. PREPARE ROUGH OPENING READY TO RECEIVE NEW DOOR AND DOOR FRAME ASSEMBLY. B.PROVIDE AND INSTALL NEW LEFT-HAND REVERSE GALVANNEALED DOOR AND DOOR FRAME IN EXISTING ROUGH OPENING. FIELD VERIFY SIZE PRIOR TO ORDERING. PROVIDE NEW DOOR HARDWARE TO MATCH EXISTING REMOVED HARDWARE FROM ORIGINAL DOOR (INCLUDE DOOR CLOSER WITH HOLD OPEN ARM. DO NOT REUSE EXISTING REMOVED DOOR HARDWARE). FUNCTION AND FINISH TO MATCH EXISTING, FIELD VERIFY. PAINT NEW DOOR AND DOOR FRAME WITH EXTERIOR SEMI-GLOSS LATEX ENAMEL. COLOR TO MATCH EXISTING, FIELD VERIFY. C.EXISTING DOWNSPOUT WITH BOTTOM ELBOW TURNOUT AT EAST CORNER OF NORTH WALL TO BE REMOVED/SALVAGED/RELOCATED TO NORTH CORNER OF EAST WALL. ROUGHLY 12” OF DOWNSPOUT LEADER FROM EXISTING GUTTER TO REMAIN. D.PROVIDE TRANSITION DOWNSPOUT PIECE OF SAME SIZE, PROFILE, AND COLOR FROM REMAINING LEADER TO TOP OF DOWNSPOUT AT NEW LOCATION. PROVIDE STRAPS (TO MATCH EXISTING) AS REQUIRED FOR SECURED FASTENING OF DOWNSPOUT TO WALL. SHEET KEYNOTES DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 9 P M ABBREVIATIONS FOOT, FEET INCH, INCHES NUMBER PERCENT AND AT APPROXIMATELY LESS THAN EQUALS GREATER THAN AMPERE(-S) AIR CONDITIONING ANALOG TO DIGITAL AUTO/MANUAL ABANDON(-ED) ALTERNATING CURRENT AMPERE FRAME ARC-FAULT CIRCUIT INTERRUPTER ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ANALOG INPUT AMPERES INTERRUPTING CAPACITY ANNUNCIATOR ANTENNA ANALOG OUTPUT APPROXIMATE(-LY) ARCHITECT(-URAL) AMMETER SWITCH ADJUSTABLE SPEED DRIVE (DC) AMPERE TRIP AUTOMATIC TRANSFER SWITCH AUTOMATIC AUXILIARY AMERICAN WIRE GAGE BATTERY BARE COPPER BREAKER CONDUCTOR, CONTACT CONSTANT SPEED CABINET CALCULATION(S) CATEGORY CATCH BASIN CLOSED-CIRCUIT TELEVISION CHEMI(-CAL, -STRY) CLASSIFICATION I, DIVISION 1 CLASSIFICATION I, DIVISION 2 CIRCUIT CLEAR(-ANCE) CONTROLLED LOW STRENGTH MATERIAL CONDUIT ONLY COAXIAL COMMON COMMUNICATION CONDUIT CONTROL POWER TRANSFORMER CONTROL RELAY CURRENT TRANSFORMER CONTROL CUBIC INCH(-ES) DIRECT CURRENT DISTRIBUTED CONTROL SYSTEM DEGREE(-S) DEGREES CELSIUS DEGREES FARENHEIT DEMOLISH DISCRETE INPUT DIAMETER DIAGRAM DISCONNECT DISTRIBUTION DISCRETE OUTPUT DOUBLE POLE, DOUBLE THROW DOUBLE POLE, SINGLE THROW DOOR DETAIL(-S) DUPLEX EFFICIENCY EFFLUENT ELECTRIC(-AL) ELEMENTARY EMERGENCY ENCLOSURE ETHERNET ENGINEER ENVIRONMENTAL PROTECTION AGENCY EQUIPMENT ESTIMATE(-D) EMERGENCY STOP ET CETERA ELAPSED TIME METER ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE EXISTING EXPANSION EXTERNAL FIRE ALARM FACILIT(-Y, -IES) FEEDER FIGURE FULL LOAD AMPERES ' " # % & @ < = > A A/C A/D A/M ABAN(-D) AC AF AFCI AFF AFG AI AIC ANN ANT AO APPROX ARCH AS ASD AT ATS AUTO AUX AWG BATT BC BKR C C/S CAB CALC(S) CAT CB CCTV CHEM CID1 CID2 CKT CLR CLSM CO COAX COM COMM COND CPT CR CT CTRL CU IN DC DCS DEG DEG C DEG F DEMO DI DIA DIAG DISC DISTR DO DPDT DPST DR DTL(-S) DUP EFFIC EFFL ELEC ELEM EMERG ENCL ENET ENGR EPA EQPM EST E-STOP ETC ETM EUSERC EXIST EXP EXT FA FACIL FDR FIG FLA +- 1.SHEETS E-1 THROUGH E-3 CONTAIN GENERALIZED ABBREVIATIONS AND LEGENDS. THIS CONTRACT MAY NOT USE ALL INFORMATION SHOWN ON THOSE SHEETS. 2.THE INSTALLATION OF ALL EQUIPMENT, RACEWAYS, CONDUCTORS, AND CABLES SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES AND UTILITY COMPANY STANDARDS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE UTILITY COMPANY AND VERIFY THEIR REQUIREMENTS. 3.ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING THE PROJECT TO VERIFY THE SCOPE OF WORK WITH FIELD CONDITIONS. PARTICULAR ATTENTION SHOULD BE GIVEN TO NEW CONDUIT RUNS IN EXISTING BUILDINGS. 4.NOTIFY THE ENGINEER IMMEDIATELY IN WRITING IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF INFORMATION OR ANY OTHER REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER. 5.CONDUIT ROUTING SHOWN ON PLAN DRAWINGS IS DIAGRAMMATIC ONLY. RACEWAYS SHALL BE INSTALLED IN A MANNER TO PREVENT CONFLICTS WITH EQUIPMENT OR STRUCTURAL CONDITIONS. EXPOSED RACEWAYS SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO BEAMS AND WALLS. REFER ALSO TO THE CONTRACT SPECIFICATIONS. 6.VERIFY THE EXACT LOCATION OF TERMINAL BOXES AND CONDUIT ENTRANCES TO ALL EQUIPMENT AGAINST APPROVED SHOP DRAWINGS BEFORE STUBBING UP CONDUITS. CONDUIT STUB-UPS SHALL NOT BE MORE THAN 6 INCHES FROM THE CENTERLINE OF TERMINAL BOXES. 7.CONNECTIONS BETWEEN RIGID CONDUIT AND MOTOR TERMINAL BOXES OR SIMILAR EQUIPMENT SUBJECT TO VIBRATION SHALL BE FLEXIBLE LIQUID-TIGHT CONDUIT. 8.CONDUITS SHALL BE TERMINATED SO AS TO PERMIT NEAT CONNECTION TO MOTORS AND OTHER EQUIPMENT. 9.CONDUITS FOR FUTURE EQUIPMENT OR EXTENSIONS SHALL BE TERMINATED AS SHOWN IN THE DETAILS OR AS SPECIFIED. 10.LOCATIONS OF PULLBOXES ARE APPROXIMATE. COORDINATE EXACT LOCATION IN THE FIELD TO ENSURE 6 INCHES (MINIMUM) CLEARANCE FROM MECHANICAL PIPING FLOW LINES. 11.ONLY MAJOR PULLBOXES ARE SHOWN. PROVIDE ADDITIONAL PULLBOXES WHERE REQUIRED TO MAKE A WORKABLE INSTALLATION. 12.PERFORM WORK IN ACCORDANCE WITH THE DETAILS WHETHER OR NOT THEY ARE REFERENCED ON THE DRAWINGS. 13.VERIFY ALL COLOR REQUIREMENTS BEFORE ORDERING MATERIALS. 14.THE WIRING DIAGRAMS, QUANTITY AND SIZE OF WIRES AND CONDUIT REPRESENT A SUGGESTED ARRANGEMENT BASED UPON SELECTED STANDARD COMPONENTS OF ELECTRICAL EQUIPMENT. MODIFICATIONS ACCEPTABLE TO THE ENGINEER MAY BE MADE BY THE CONTRACTOR TO ACCOMMODATE EQUIPMENT ACTUALLY PURCHASED. THE BASIC SEQUENCE AND METHOD OF CONTROL MUST BE MAINTAINED AS INDICATED ON THE DRAWINGS AND/OR SPECIFICATIONS. 15.REFER TO THE MECHANICAL DRAWINGS FOR CERTAIN CONTROL DIAGRAMS, EXACT LOCATIONS OF MECHANICAL EQUIPMENT, AND FOR CERTAIN CONNECTIONS TO BE MADE TO ELECTRICAL CIRCUITS. 16.CONDUIT SIZE AND FILL SHALL BE AS INDICATED ON THE CONDUIT AND CABLE SCHEDULES. WHERE NO SIZE IS SHOWN, THE CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE ADOPTED BY THE AUTHORITY HAVING JURISDICTION. MINIMUM CONDUIT SIZE IS 3/4 INCH, EXCEPT WHERE ENCASED OR BURIED. MINIMUM ENCASED OR BURIED CONDUIT SIZE IS 1 INCH. 17.PROVIDE EXPANSION OR EXPANSION AND DEFLECTION FITTINGS FOR ALL CONDUIT RUNS CROSSING EXPANSION JOINTS. REFER TO THE STRUCTURAL DRAWINGS FOR LOCATIONS OF EXPANSION JOINTS. 18.PROVIDE 3/16 INCH NYLON PULL ROPE IN EACH EMPTY CONDUIT. 19.FOR LIGHTING AND RECEPTACLE SYSTEMS, ONLY CIRCUIT NUMBERS ARE SHOWN. PROVIDE ALL NECESSARY CONDUITS, WIRES, FITTINGS, JUNCTION BOXES AND NECESSARY COMPONENTS SHOWN OR NOT SHOWN ON THE DRAWINGS, TO MAKE THE ELECTRICAL INSTALLATION COMPLETE AND OPERATIONAL. SIZE CONDUITS AND WIRING IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. ALL CONDUIT RUNS SHALL BE CONCEALED UNLESS INDICATED OTHERWISE. CIRCUIT LOADING SHALL BE AS INDICATED IN THE PANEL SCHEDULES. ALL LIGHTING AND RECEPTACLE CIRCUITS SHALL INCLUDE GROUND WIRE. 20.MOUNT LUMINAIRES ACCORDING TO THE MOUNTING HEIGHT GIVEN ON THE DRAWINGS, WITH THE DISTANCE BEING MEASURED FROM THE BOTTOM OF THE LUMINAIRE TO THE FINISHED FLOOR. PROVIDE APPROPRIATE BRACKETS AND HARDWARE FOR MOUNTING. 21.ALL RECEPTACLES IN OUTDOOR AND ANTICIPATED WET AREAS SHALL BE GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLES WITH WEATHERPROOF WHILE IN-USE COVERS. 22.ALL FREE STANDING ELECTRICAL EQUIPMENT AND CONTROL PANELS SHALL BE SET ON CONCRETE HOUSEKEEPING PADS WITH LEVELING CHANNELS EMBEDDED IN THE PAD. 23.ALL PANELBOARDS SHALL BE MOUNTED SO THAT THE DISTANCE FROM THE CENTERLINE OF THE TOP CIRCUIT BREAKER OPERATING HANDLE IN THE UPPERMOST POSITION TO THE FINISHED FLOOR SHALL NOT EXCEED 6'-7". 24.ALL SURFACE MOUNTED PANELS AND PANELBOARDS ON THE INTERIOR OF EXTERIOR WALLS ABOVE GRADE OR IN OTHER LOCATIONS CONSIDERED DAMP OR WET SHALL BE MOUNTED SO AS TO MAINTAIN A 1/4 INCH (MINIMUM) AIR SPACE BETWEEN THE ENCLOSURE AND THE WALL. 25.PROVIDE LOCKOUTS IN STRICT ACCORDANCE WITH OWNER'S REQUIREMENTS. 26.REFER TO THE SINGLE LINE DIAGRAMS, EQUIPMENT ELEVATIONS, PANELBOARD SCHEDULES, AND COMPONENT/DEVICE LABELS IN THE CONTROL SCHEMATICS FOR NAMEPLATE INFORMATION. SEE THE CONTRACT SPECIFICATIONS FOR NAMEPLATE SIZE, COLOR, MATERIAL, AND PLACEMENT REQUIREMENTS. 27."NORMAL" STATUS OF SWITCHES OR CONTACTS SHOWN IN CONTROL SCHEMATICS IS THE SHELF POSITION. 28.POLLUTION CONTROL LIMITS FOR THE SELECTION OF FINISH MATERIALS SHALL BE IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, AS ADOPTED BY THE CITY OF CARLSBAD. FLEXIBLE FIBER OPTIC FREQUENCY FOOT, FEET FUSE FUTURE FULL VOLTAGE, NON REVERSING FULL VOLTAGE, REVERSING FORWARD GROUND (ELECTRICAL) GRANULAR ACTIVATED CARBON GALLON(-S) GROUND-FAULT CIRCUIT INTERRUPTER GROUND GALVANIZED RIGID STEEL HIGH, HEIGHT HEAT DETECTOR HIGH DENSITY POLYETHYLENE HANGER HANDHOLE HUMAN MACHINE INTERFACE HAND-OFF-AUTOMATIC HAND-OFF-REMOTE HORSEPOWER HOUR(-S) HEATER HEATING, VENTILATING, AND AIR CONDITIONING HERTZ (CYCLES PER SECOND) INSTRUMENTATION AND CONTROL INPUT/OUTPUT INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS INDICATING LIGHT INCH(-ES) INSTANTANEOUS INSTRUMENT(-ATION) INTERNET PROTOCOL INFRARED INTRINSICALLY SAFE INTERNATIONAL SOCIETY OF AUTOMATION ISOLAT(-E, -ION) INTRINSICALLY SAFE RELAY JUNCTION BOX KILOAMPERE(-S) THOUSANDS OF CIRCULAR MILS KILOHERTZ KILOVOLT(-S) KILOVOLT-AMPERE(-S) KILOVOLT-AMPERE(-S) REACTIVE KILOVOLT-AMPERE REACTIVE HOUR(-S) KILOWATT(-S) KILOWATT HOUR(-S) LENGTH, LINE LIGHTNING ARRESTER LOCAL AREA NETWORK POUND(-S) LOCAL CONTROL PANEL LOCAL CONTROL STATION LOWER EXPLOSIVE LIMIT LOCATION LOCAL-OFF-REMOTE LOCK-OUT, TAG-OUT LIGHTING PANELBOARD LOCAL-REMOTE LIMIT SWITCH LIGHT LIGHTING LOW VOLTAGE MILLIAMPERE(-S) MAXIMUM MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MOTOR CIRCUIT PROTECTOR MECHANICAL MANUFACTURER MANHOLE MEGAHERTZ ONE-THOUSANDTH OF AN INCH MINIMUM, MINUTE(-S) MISCELLANEOUS MAIN LUGS ONLY MULTIMODE MAXIMUM OVERCURRENT PROTECTION MODIF(-Y, -ICATIONS) MOTOR OPERATED VALVE MOUNT(-ED, -ING) MOTOR MANUAL TRANSFER SWITCH MEDIUM VOLTAGE NORTH, NEUTRAL NOT APPLICABLE SODIUM HYPOCHLORITE SODIUM HYDROXIDE NORMALLY CLOSED NATIONAL ELECTRICAL CODE (NFPA 70) NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION FLEX FO FREQ FT FU FUT FVNR FVR FWD G GAC GAL GFCI GND GRS H HD HDPE HGR HH HMI HOA HOR HP HR(S) HTR HVAC HZ I&C I/O IEEE IL IN INST INSTR IP IR IS ISA ISO ISR JB KA KCMIL KHZ KV KVA KVAR KVARH KW KWH L LA LAN LB(-S) LCP LCS LEL LOC LOR LOTO LP L-R LS LT LTG LV mA MAX MCB MCC MCP MECH MFR MH MHZ MIL(-S) MIN MISC MLO MM MOCP MOD(-S) MOV MT(-D, -G) MTR MTS MV N N/A NAOCL NAOH NC NEC NECA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION INTERNATIONAL ELECTRICAL TESTING ASSOCIATION NOT FOR CONSTRUCTION NATIONAL FIRE PROTECTION ASSOCIATION AMMONIA NOT IN CONTRACT NORMALLY OPEN, NUMBER NORMAL NOT TO SCALE OPEN/CLOSE OZONE OPEN DRIP PROOF OWNER FURNISHED, CONTRACTOR INSTALLED OPERATOR INTERFACE TERMINAL THERMAL OVERLOAD RELAY ORIGINAL OPEN/STOP/CLOSE OVER TEMPERATURE POLE PUBLIC ADDRESS PULLBOX, PUSHBUTTON PIECE(-S), PHOTOCELL POINT OF COMMON COUPLING PHOTOELECTRIC POWER FACTOR POWER FACTOR RELAY PHASE PROGRAMMABLE LOGIC CONTROLLER POWER MONITOR PANEL PANELBOARD POWER OVER ETHERNET POWER POLE PRIMARY PRESSURE RELIEF VALVE, PRESSURE REDUCING VALVE POWER SUPPLY POTENTIAL TRANSFORMER POLYVINYL CHLORIDE POWER RADIUS RECEPTACLE REPEAT CYCLE TIMER REMOTE INPUT/OUTPUT ROOM REMOTE REVOLUTIONS PER MINUTE RESET RESET TIMER REMOTE TELEMETRY UNIT REDUCED VOLTAGE, SOLID STATE START/STOP SUPERVISORY CONTROL AND DATA ACQUISITION SILICON CONTROLLED RECTIFIER SMOKE DETECTOR SECONDARY SERVICE ENTRANCE RATED SIGNAL SHIELDED SHEET SINGLEMODE SET POINT SURGE PROTECTIVE DEVICE SINGLE POLE, DOUBLE THROW SPECIFICATION(-S) STAINLESS STEEL, SOLID STATE SHORTING TERMINAL BLOCK STANDARD(-S) STEEL SHIELDED TWISTED PAIR STRUCTUR(-E, -AL) SWITCHBOARD SWITCHGEAR SYNCHRONIZING TIME(-R) TERMINAL BLOCK TRAY CABLE TRANSMISSION CONTROL PROTOCOL TOTALLY ENCLOSED FAN COOLED TELEPHONE TEMPERATURE, TEMPORARY TOTALLY ENCLOSED NON-VENTILATED THROUGH TOTAL, TOTALIZE(R) THERMOSTAT TYPICAL UNDERGROUND UNDERWRITERS LABORATORIES UNKNOWN UNINTERRUPTIBLE POWER SUPPLY UNSHIELDED TWISTED PAIR ULTRAVIOLET VOLTS VARIABLE SPEED VOLT-AMPERES NEMA NETA NFC NFPA NH3 NIC NO NORM NTS O/C O3 ODP OFCI OIT OL ORIG OSC OT P PA PB PC(-S) PCC PE PF PFR PH PLC PM PNL PNLBD POE PP PRI PRV PS PT(-S) PVC PWR R, RAD RCPT RCT RIO RM RMT RPM RST RT RTU RVSS S/S SCADA SCR SD SEC SER SGNL (SH) SHT SM SP SPD SPDT SPEC(-S) SS STB STD(-S) STL STP STRC SWBD SWGR SYNC T TB TC TCP TEFC TEL TEMP TENV THRU TOT TSTAT TYP UG UL UNKN UPS UTP UV V V/S VA VARIES, VARIABLE, VOLT-AMPERES REACTIVE VENDOR CONTROL PANEL VARIABLE FREQUENCY DRIVE (AC) VACUUM FAULT INTERRUPTER VOLTMETER SWITCH WIDE, WIDTH, WIRE, WATTS, WEST WITH WITHOUT WIDE AREA NETWORK WATT-HOUR DEMAND METER WATT-HOUR METER WEATHERPROOF, WEATHER PROTECTED WEATHER RESISTANT WATER TREATMENT PLANT WATER WASTEWATER WASTEWATER TREATMENT PLANT TRANSFORMER EXPLOSION PROOF VAR VCP VFD VFI VS W W/ W/O WAN WHDM WHM WP WR WTP WTR WW WWTP XFMR XP ELECTRICAL NOTES ELECTRICAL DEMOLITION NOTES 1.BIDDING CONTRACTORS SHALL VISIT THE SITE TO ASSESS THE SCOPE OF DEMOLITION, REMOVAL AND MODIFICATION WORK. 2.ELECTRICAL CONTRACTOR AND THE OWNER SHALL DE-ENERGIZE ALL WIRING PRIOR TO REMOVAL OF EQUIPMENT, DEVICES, MOTORS INSTRUMENTATION, CONTROL PANELS, ETC. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FROM THE OWNER. 3.EXPOSED RACEWAYS: REMOVE CONDUIT, WIRES, AND BOXES. PATCH TO MATCH EXISTING. FINISH ALL OPENINGS LEFT IN WALLS AND FLOORS. 4.CONCEALED CONDUITS IN THE SLAB: REMOVE EXISTING WIRES TO THE EXTENT POSSIBLE AND ABANDON CONDUITS IN THE SLAB. CUT CONDUIT FLUSH AND PATCH THE FLOOR TO MATCH EXISTING. 5.CONTROL PANELS: ELECTRICAL CONTRACTOR SHALL DE-ENERGIZE AND REMOVE ALL CONDUIT AND WIRE AS DESCRIBED IN NOTES 3 AND 4. CONTRACTOR SHALL REMOVE PANELS AS NOTED ON THE CONTRACT DRAWINGS. 6.MOTOR CONTROL CENTERS: DISCONNECT AND REMOVE ALL CONDUITS AND WIRING TO EXISTING STARTERS AND/OR BREAKERS, PANELBOARDS, BRANCH CIRCUITS, INTERLOCKS AND STATUS WIRING WITHIN MCC. 7.REFER TO THE CONTRACT SPECIFICATIONS FOR ADDITIONAL ELECTRICAL DEMOLITION AND REMOVAL REQUIREMENTS. 8.CONSTRUCTION AND DEMOLITION OPERATIONS SHALL INCORPORATE SALVAGE AND/OR RECYCLING OF MATERIALS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, AS ADOPTED BY THE CITY OF CARLSBAD. POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 11 GENERAL ELECTRICAL E-1 ABBREVIATIONS AND NOTES DPH JRM - DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 SINGLE LINE DIAGRAM SYMBOLS PACKAGED EQUIPMENT LOAD (IN KW OR KVA) AND AMPERES AS INDICATED LIGHTNING ARRESTOR AND SURGE CAPACITOR KEY INTERLOCK DIGITAL INPUT TO PLC/RTU/DCS SOLID STATE MOTOR PROTECTIVE DEVICE DIGITAL OUTPUT FROM PLC/RTU/DCS NORMALLY CLOSED DIGITAL OUTPUT FROM PLC/RTU/DCS NORMALLY OPEN ANALOG INPUT TO PLC/RTU/DCS 4-20 mA (UNLESS INDICATED OTHERWISE) LOCATION SYMBOL LEGEND SHOWN ON SCHEMATIC DRAWINGS ALL DEVICES ARE LOCATED IN THE MCC UNLESS INDICATED OTHERWISE ANALOG OUTPUT FROM PLC/RTU/DCS 4-20 mA (UNLESS INDICATED OTHERWISE) POTENTIAL TRANSFORMER RATIO AND NUMBER OF PT'S AS INDICATED CURRENT TRANSFORMER RATIO AND NUMBER OF CT'S AS INDICATED ELECTRICAL MOTOR OPERATED VALVE WITH INTEGRAL REVERSING STARTER SURGE PROTECTIVE DEVICE HP FLA OL # CONTACTOR NUMBER INDICATES NEMA SIZE MEDIUM VOLTAGE DRAWOUT CIRCUIT BREAKER # * ETM 5A X X CR# CR 1 XXXX, XXXX FS LS TS ZS TR TR TR TR 52 E-STOP PS 5 EARTH GROUND CONNECTION DISCONNECT SWITCH 3 POLE EXCEPT WHERE NOTED RATING IN AMPERES AS INDICATED AUTOMATIC OR MANUAL TRANSFER SWITCH RATING AND CONFIGURATION AS INDICATED SHUNT TRIP FUSE SIZE AS INDICATED LOW VOLTAGE THERMAL-MAGNETIC CIRCUIT BREAKER 3-POLE EXCEPT WHERE NOTED X = CIRCUIT NUMBER OR LOCATION (SEE ELEVATION) POWER OR DISTRIBUTION TRANSFORMER CONFIGURATION AND RATING AS INDICATED MOTOR HORSEPOWER AND FULL LOAD AMPERES AS INDICATED GENERATOR RATINGS AS INDICATED OVERLOAD (THERMAL OR SOLID STATE) AMMETER SWITCH VOLTMETER SWITCH RELAY DEVICE FUNCTION # PER ANSI NUMBER C37.2 TERMINATOR / POTHEAD CAPACITOR RATING IN KVAR AS INDICATED FUSE RATING IN AMPERES ELAPSED TIME METER MOTOR CONTROL DEVICE COIL **= TYPE CR = CONTROL RELAY TD = TIME DELAY RELAY ISR = INTRINSICALLY SAFE RELAY PC = PHOTOCELL INDICATING LIGHT PUSH-TO-TEST INDICATING LIGHT X = COLOR A = AMBER B = BLUE G = GREEN R = RED W = WHITE SINGLE POLE SWITCH NORMALLY OPEN / CLOSED EMERGENCY PUSHBUTTON NORMALLY OPEN / CLOSED PUSHBUTTON NORMALLY OPEN / CLOSED DISCONNECT SWITCH 1-POLE / 3-POLE MULTI-POSITION SELECTOR SWITCH THREE-POSITION SELECTOR SWITCH X:INDICATES CONTACTS CLOSED H-O-A:HAND-OFF-AUTO L-O-R:LOCAL-OFF-REMOTE O-S-C:OPEN-STOP-CLOSE TERMINAL CONTROL POWER TRANSFORMER HEATER CIRCUIT BREAKER OR MCP AS NOTED 1-POLE / 3-POLE EARTH GROUND CONNECTION CONTACT NORMALLY OPEN / CLOSED BUZZER BELL HORN MCP CONTROL SCHEMATIC SYMBOLS BATTERY DELTA-WYE DELTA-WYE GROUNDED DELTA-DELTA CHASSIS GROUND CONNECTION (NOT NECESSARILY EARTH GROUNDED) ** # BUS BUS (EXISTING) FEEDER FEEDER (EXISTING) XOO OOX H AO XOO OOX L R THREE-POSITION SELECTOR SWITCH WITH SPRING-RETURN MOMENTARY CONTACT TWO-POSITION SELECTOR SWITCH X:INDICATES CONTACTS CLOSED L-R:LOCAL-REMOTE O-C:OPEN-CLOSE A-M:AUTO-MANUAL XOO OOX O S C CONDUCTORS - CONNECTED CONDUCTORS - NOT CONNECTED AMPS TRIP GEN 5A LOW VOLTAGE MOTOR CIRCUIT PROTECTOR 3-POLE EXCEPT WHERE NOTED X = CIRCUIT NUMBER OR LOCATION (SEE ELEVATION) AMPS FRAME AMPS CONTINUOUS 5A LOW VOLTAGE DRAWOUT CIRCUIT BREAKER INCLUDING L-S-I-G SETTINGS UNLESS NOTED OTHERWISE L = LONG TIME S = SHORT TIME I = INSTANTANEOUS G = GROUND FAULT 400AF 200AT OVERLOAD (THERMAL OR SOLID STATE) 30A FUSED DISCONNECT SWITCH 3 POLE EXCEPT WHERE NOTED RATINGS IN AMPERES AS INDICATED 30A 25A METERING DEVICE *= METER TYPE WHM = WATT HOUR METER WM = WATT METER AM = AMMETER VM = VOLTMETER PFM = POWER FACTOR METER SSM = SOLID STATE METER SPD SSMP 15/25 AUTO SYNCHRONIZER RELAY 25 SYNCHRONISM CHECK RELAY 27 UNDERVOLTAGE RELAY 27/59 UNDER/OVERVOLTAGE RELAY 32 DIRECTIONAL POWER RELAY 37 UNDERCURRENT RELAY 38 HIGH TEMP (BEARING) 39 VIBRATION RELAY 40 LOSS OF FIELD/UNDER EXCITATION RELAY 41 FIELD CONTACTOR 43 SELECTOR SWITCH 46 CURRENT IMBALANCE RELAY 47 PHASE SEQUENCE/FAILURE RELAY 48 GROUND FAULT INCOMPLETE SEQUENCE RELAY 49 HIGH TEMP (OIL OR STATOR) 50/51 INST/TIME OVERCURRENT RELAY 50/51G INST/TIME DIRECTLY CONNECTED GND OVERCURRENT RELAY K ST NORMALLY OPEN CONTACT LINE REFERENCE NORMALLY CLOSED CONTACT LINE REFERENCE M SOLENOID COIL SV-# NORMALLY OPEN,CLOSE ON REACHING LIMIT NORMALLY CLOSED, OPEN ON REACHING LIMIT DI AI AO AS VS MOV (3) 480:120 (3) RVSS ___A FVNR # VARIABLE FREQUENCY DRIVE WITH CONTROL POWER TRANSFORMER RATING IN AMPERES AS INDICATED REDUCED VOLTAGE STARTER WITH CONTROL POWER TRANSFORMER RATING IN AMPERES AS INDICATED RVSS = SOLID STATE TYPE RVAT = AUTO-TRANSFORMER TYPE VFD ___A FULL VOLTAGE COMBINATION STARTER WITH CONTROL POWER TRANSFORMER #= NEMA SIZE FVR = REVERSING TYPE FVNR = NON-REVERSING TYPE CR# __ SEC __ A NEUTRAL GROUNDING RESISTOR CURRENT RATING IN AMPERES AS NOTED TIME RATING IN SECONDS AS NOTED NEUTRAL GROUNDING RESISTORGN R COMMUNICATION JACK (ETHERNET UNLESS INDICATED OTHERWISE) RESISTANCE TEMPERATURE DETECTOR (RTD) E-STOP ZS TS PS LS FS RECEPTACLE, 120V SPECIAL RECEPTACLE, 208V OR 240V, 1-PHASE SPECIAL/WELDING RECEPTACLE, 208V OR 240V, 3-PHASE SPECIAL RECEPTACLE, 480V, 3-PHASE RECEPTACLE, 120V 1 KW # __A NORMALLY CLOSED, OPEN ON INCREASING TORQUE LIMIT SWITCHES TORQUE SWITCH TIMED CONTACTS SYMBOL NORMAL OPEN DELAYED CLOSED DELAYED OPEN TO CLOSED CLOSED TO OPEN SENSING SWITCHES CLOSE ON RISING FALLING SENSED VARIABLE FLOW LEVEL PRESSURE TEMPERATURE INSTANTANEOUS INSTANTANEOUS INSTANTANEOUSOPEN DELAYED CLOSED DELAYED INSTANTANEOUS POTENTIOMETER X 70A 100A X MCP 100A REACTOR (LINE OR LOAD DEPENDING ON PLACEMENT) 50/51N INST/TIME RESIDUALLY CONNECTED GND OVERCURRENT 51G GND FAULT RELAY 52 POWER CIRCUIT BREAKER 55 POWER FACTOR TRIP RELAY 60 VOLTAGE BALANCE 62 TIME DELAY 65 GOVERNOR LOAD SHARING/SOFT LANDING CONTROL 66 TIME BETWEEN STARTS RELAY 67 DIRECTIONAL REVERSE VAR/KW RELAY 71L LOW OIL LEVEL RELAY 81O/U OVER/UNDER FREQUENCY RELAY 83 CONTROL POWER TRANSFORMER 86 UTILITY LOCKOUT RELAY 87TL TRANSFORMER DIFFERENTIAL RELAY 87M MOTOR DIFFERENTIAL RELAY 90 VAR/PF AND CROSS CURRENT COMPENSATION CONTROLLER POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 9 P M 12 GENERAL ELECTRICAL E-2 LEGEND - I DPH JRM - DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 PLAN SYMBOLS SECURITY ACCESS DEVICE *= TYPE CR CARD READER KS KEY SWITCH KP KEYPAD RF RADIO FREQUENCY ID HH-# LUMINAIRE CALLOUT A = LUMINAIRE TYPE * = APPROXIMATE MOUNTING HEIGHT AFF CLG = CEILING MOUNT (SEE LUMINAIRE SCHEDULE FOR MORE DETAILS) BARE COPPER GROUND TO GROUND WIRE IN SLAB, OR UNDERGROUND GROUND GRID, SIZE AS NOTED VIDEO CAMERA *= TYPE F FIXED PTZ PAN-TILT-ZOOM 360 360 DEGREE FIXED S * X-#a * X-# SEMI CIRCLE DENOTES DOWNWARD CONDUIT RISER MULTIPLE CONDUIT RUN CONDUIT - ENCASED OR UNDERGROUND CONDUIT - EXPOSED OR CONCEALED CALLOUT INDICATING CONDUIT PER SCHEDULE HOME RUN TO PANELBOARD OR AS INDICATED (3/4 " CONDUIT, 2 #12, 1 #12 GND UNLESS INDICATED OTHERWISE) FLEXIBLE CONDUIT CONDUIT RUN, CONTINUES ON SAME SHEET OR AS NOTED CONDUIT - CAPPED OR SEALED OPEN CIRCLE DENOTES UPWARD CONDUIT RISER MOTOR DISCONNECT SAFETY SWITCH GROUND ROD - BURIED INSTRUMENT LUMINAIRE - STRIP OR TROFFER TYPE (SWITCHED/UNSWITCHED) X = LIGHTING PANEL DESIGNATION #= CIRCUIT NUMBER a = SWITCH DESIGNATION WALL MOUNTED LUMINAIRE (SWITCHED/UNSWITCHED) PENDANT/CEILING MOUNTED LUMINAIRE (SWITCHED/UNSWITCHED) POLE, BRACKET, ARM, AND MOUNTED LUMINAIRE WALL/CEILING MOUNTED EXIT LIGHT DIRECTIONAL ARROW WHERE INDICATED, SHADED AREA INDICATES ILLUMINATED FACE EMERGENCY LUMINAIRE WITH SELF CONTAINED BATTERY JUNCTION BOX TELEPHONE OUTLET WALL MOUNTED/FLOOR MOUNTED DATA OUTLET WALL MOUNTED/FLOOR MOUNTED TELEPHONE/DATA COMBINATION OUTLET WALL MOUNTED/FLOOR MOUNTED FIRE ALARM PULL STATION FIRE ALARM STROBE FIRE ALARM HORN X-#a M J F F F ANTENNA TV GROUND CONNECTION - BOLTED GROUND CONNECTION - EXOTHERMICALLY WELDED CONDUIT - MULTIPLE IN DUCT BANK P-135 PHOTOCELL TIME CLOCK OCCUPANCY SENSOR MOTION SENSOR GROUND ROD - IN WELL WITH BOX S * X-#SWITCH - SPECIAL PURPOSE X = LIGHTING PANEL DESIGNATION # = CIRCUIT NUMBER * = SWITCH TYPE M MOTOR RATED K KEY OPERATED T TIMER CONDUIT AND RACEWAYS GROUNDING FIRE ALARM HORN/STROBEF THERMOSTAT SD SMOKE DETECTOR HEAT DETECTORHD T FIRE PROTECTION LIGHTING RECEPTACLES MISCELLANEOUS SECURITY AND COMMUNICATION EQUIPMENT PANEL OR CABINET - AS LABELED SWBD, SWGR, MCC, LP, PNLBD, PLC, ETC TELEVISION ANTENNA/CABLE OUTLET * VC * A * TC PC O M LIGHT SWITCH X = LIGHTING PANEL DESIGNATION # = CIRCUIT NUMBER a = SWITCH DESIGNATION * = SWITCH TYPE 1 1 WAY 3 3 WAY 4 4 WAY D DIMMER RECESSED CAN LUMINAIRE (SWITCHED/UNSWITCHED) DUPLEX RECEPTACLE, 120V, WALL MOUNT NEMA 5-20R CONFIGURATION X = LIGHTING PANEL DESIGNATION # = CIRCUIT NUMBER * = RECEPTACLE TYPE WP WEATHERPROOF XP EXPLOSION PROOF GFCI GROUND FAULT CIRCUIT INTERRUPTER X-# * DUPLEX RECEPTACLE, 120V, FLOOR MOUNT NEMA 5-20R CONFIGURATION A X-# A X-# A X-#SINGLE SPECIAL RECEPTACLE, 208V OR 240V, 1-PHASE X = PANEL DESIGNATION # = CIRCUIT NUMBER A = AMPERAGE SINGLE SPECIAL/WELDING RECEPTACLE, 208V OR 240V, 3-PHASE X = PANEL DESIGNATION # = CIRCUIT NUMBER A = AMPERAGE SINGLE SPECIAL RECEPTACLE, 480V, 3-PHASE X = PANEL DESIGNATION # = CIRCUIT NUMBER A = AMPERAGE UNDERGROUND RACEWAY HANDHOLE DIMENSIONS AS NOTED MH-# UNDERGROUND RACEWAY MANHOLE DIMENSIONS AS NOTED POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 9 P M 13 GENERAL ELECTRICAL E-3 LEGEND - II DPH JRM - DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 EXISTING GENERATOR (CATERPILLAR 3306), EXHAUST PIPING, FUEL VENT PIPING AND COOLING SYSTEM TO BE REMOVED. EQUIPMENT PAD SHALL REMAIN IN PLACE AND SERVE AS THE EQUIPMENT PAD FOR THE NEW GENERATOR AND SUBBASE FUEL TANK. CONTRACTOR SHALL WRAP NEW EXHAUST PIPING TO MATCH EXISTING CEILING. CONTRACTOR SHALL PROTECT IN PLACE EXISTING BUILDING OPENINGS AND UTILIZE THEM FOR NEW GENERATOR COOLING LOUVER, FUEL TANK VENTILATION AND DIESEL PARTICULATE FILTER EXHAUST SYSTEM. IF MODIFICATIONS ARE REQUIRED, CONTRACTOR SHALL PATCH SOUND MATERIAL TO MATCH EXISTING AND PATCH AND PAINT EXTERIOR OF BUILDING OPENINGS. CONTRACTOR SHALL REMOVE THE EXISTING AUTOMATIC TRANSFER SWITCH ZENITH MX2000 AND ASSOCIATED CABLING. PROTECT EQUIPMENT PAD FOR INSTALLATION OF NEW TRANSFER SWITCH. CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT NEW CABLES, SIZED IN KIND, BETWEEN UTILITY SWITCHBOARD AND ATS AND GENERATOR (VIA MTS) AND ATS. WIRE COMPLETE IN ACCORDANCE WITH THE NEC AND LOCAL CODES TO FURNISH A COMPLETE AND OPERABLE OPTIONAL STANDBY POWER SYSTEM. CONTRACTOR SHALL REMOVE EXHAUST FAN. GENERATOR ROOM HAS 2" +/- RIGID INSULATION ON WALLS AND CEILING. CONTRACTOR SHALL FURNISH AND INSTALL STAINLESS STEEL STRUT FOR DEVICES AND CONDUIT SUPPORTS OF SUFFICIENT DEPTH TO CLEAR. CONTRACTOR SHALL PATCH SOUND MATERIAL BASED ON THE REQUIRED OPENING(S). EXISTING EXHAUST PIPING TO BE REPLACED WITH NEW EXHAUST PIPING. CONTRACTOR SHALL PROTECT IN PLACE EXISTING BUILDING OPENING FOR EXHAUST PIPING AND UTILIZE THE OPENING FOR NEW DIESEL PARTICULATE FILTER EXHAUST SYSTEM. IF MODIFICATIONS ARE REQUIRED. CONTRACTOR SHALL PATCH SOUND MATERIAL TO MATCH EXISTING AND PATCH AND PAINT EXTERIOR OF BUILDING OPENINGS. POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 4 9 P M 14 ELECTRICAL DEMOLITION DETAILS E-4 DPH JRM - E-8 1 GENERATOR DEMOLITION E-9 2 AUTOMATIC TRANSFER SWITCH DEMOLITION E-8 3 EXHAUST PIPING DEMOLITION E-8 4 EXHAUST FAN DEMOLITION E-8 5 HOSE RACK DEMOLITION AND MTS INSTALLATION EQUIPMENT PAD, SEE STRUCTURAL DETAIL S-3342 ON SHEET S-2 FOR FURTHER DETAIL NEW 600A MTS IN NEMA 4X, 316SS ENCLOSURE NEW 400A GENERATOR RECEPTACLE REMOVE EXISTING BINDERS AND HOLDERS FROM WALL AND RETURN TO OWNER DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 ESMT ESMT ESMT ESM T ESMT ESMT ESMT ESMT ESMT ESMT ESMT ESMT ESMT ESMT ESM T ESM T ESM T P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/LP/L P/L P/L P/L P/L ODOR CONTROL SYSTEM 4 FT DIAMETER SURGE TANK GENERATOR BUILDING SEE SHEET E-9 FOR DEMOLITION AND MODIFICATION REQUIREMENTS WITHIN PUMP STATION ELECTRICAL ROOM NEW 600A MANUAL TRANSFER SWITCH IN NEMA 4X 316SS ENCLOSURE SHEET KEYNOTES A.CONTRACTOR SHALL POTHOLE EXISTING DUCTBANK AND LOCATE EXISTING CONDUITS 104 (2 - 3" CONDUITS EACH WITH 3#350MCM AND 1#1GND). ONCE DUCTBANK HAS BEEN IDENTIFIED, CONTRACTOR SHALL FURNISH AND INSTALL NEW MANUAL TRANSFER SWITCH (MTS) AT APPROXIMATE LOCATION SHOWN. B.CONTRACTOR SHALL DISCONNECT AND REMOVE CABLES IN CONDUITS 104 AND INTERCEPT AND RE-ROUTE EXISTING CONDUITS 104 TO NEW MANUAL TRANSFER SWITCH. CONTRACTOR SHALL ROUTE CONDUIT 104A (2-3" CONDUITS) FROM NEW MTS TO EXISTING DUCTBANK AND TIE BACK IN TO THE EXISTING POWER CONDUIT 104 (2-3" CONDUITS). CONDUIT 104A WILL BE THE CONDUIT TAG FOR THE RACEWAYS SYTEM BETWEEN MTS AND GENERATOR. AFTER CONDUITS ARE RE-ROUTED AND SUCCESSFULLY MANDRELED, CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT 2 SETS OF 3#350MCM & 1#1GND BETWEEN THE EXISTING ATS AND NEW MTS. CONTRACTOR SHALL PROVIDE SUFFICIENT SLACK IN CONDUCTORS AT THE EXISTING ATS TO TERMINATE TO NEW ATS ONCE ITS REPLACED. WIRE COMPLETE IN ACCORDANCE WITH NEC AND LOCAL CODES. C.CONTRACTOR SHALL FURNISH AND INSTALL A TEMPORARY 250KW GENERATOR FOR STANDBY POWER REQUIREMENTS WHILE THE PERMANENT GENERATOR IS DISCONNECTED AND BEING REPLACED. CONTRACTOR SHALL UTILIZE THE CONNECTIONS AT THE MTS TO CONNECT THE TEMPORARY GENERATOR. CONTRACTOR SHALL COORDINATE WITH APCD TO OBTAIN THE NECESSARY PERMITS FOR THE TEMPORARY GENERATOR. D.CONTRACTOR SHALL FURNISH, INSTALL, AND CONNECT NEW CONDUIT 104B BETWEEN THE NEW MTS AND THE NEW GENERATOR RECEPTACLE. CONDUIT 104B SHALL BE 4" WITH A WIRE FILL OF 3#500MCM & 1#1GND. WIRE COMPLETE IN ACCORDANCE WITH THE NEC AND LOCAL CODES. A B EXISTING CONDUITS 104, 118, 119, AND 120 POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 5 0 P M 15 ELECTRICAL SITE PLAN E-5 DPH JRM - C A B SEE SHEET E-8 FOR DEMOLITION AND MODIFICATION REQUIREMENTS WITHIN THE GENERATOR ROOM SCALE: 1" = 10' ELECTRICAL SITE PLAN EXISTING CONDUITS 104 AND 119 EXISTING CONDUITS 118 AND 120NEW 400A GENERATOR RECEPTACLE D DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 SDG&E PADMOUNT XFMR 12KV PER SDG&E WH 600A3P N G N G 500A 18KAIC3P N E GEN DIESEL ENGINE 480V, 3PH, 4W 250KW, 0.8PF ATS MAIN C.B. 30KAIC 600A 3P MCB PFR 20A3P CRANE 200A3P SS JJ LOS ZS-P1 BYPASS MFR CABLES 200A3P SS JJ LOS ZS-P2 BYPASS P1 P2 200A3P SS JJ LOS ZS-P3 BYPASS P3 GND GROUND RING & CW PIPE 20A3P COMMINUTOR CP 8A 40A2P 15KVA TR-PB2 480V PRI 120/240V SEC PNL PB2 120/240V 1PH, 3W 30 POS 200A3P 200A3P 1 1 SUMP PUMP NO. 1 SUMP PUMP NO. 2 40A2P PNL PB1 120/240V 1PH, 3W 30 POS15KVA 1PH, 3W 480V PRI 120/240V SEC 15A3P 2 AIR COMPRESSOR MCC 600A, 480V, 3PH, 3W 42KA BRACING VCP 30A NEMA 4X LOCATED IN CHEMICAL ROOM 125 156 FLA 0.75 0.75 MFR CABLES 125 156 FLA MFR CABLES 125 156 FLA SDG&E PADMOUNT XFMR 12KV PER SDG&E WH 600A3P N G NG 600AF 500AT MAIN C.B. 30KAIC 600A 3P MCB PFR 20A3P CRANE 200A3P SS J LOS ZS-P1 BYPASS MFR CABLES 200A3P SS LOS ZS-P2 BYPASS P1 P2 200A3P SS LOS ZS-P3 BYPASS P3 GND GROUND RING & CW PIPE 20A3P COMMINUTOR CP 8A 40A2P 15KVA TR-PB2 480V PRI 120/240V SEC PNL PB2 120/240V 1PH, 3W 30 POS 200A3P 200A3P 1 1 SUMP PUMP NO. 1 SUMP PUMP NO. 2 40A2P PNL PB1 120/240V 1PH, 3W 30 POS15KVA 1PH, 3W 480V PRI 120/240V SEC 15A3P 2 AIR COMPRESSOR MCC 600A, 480V, 3PH, 3W 42KA BRACING VCP NEMA 4X LOCATED IN CHEMICAL ROOM 125 156 FLA 0.75 0.75 MFR CABLES 125 156 FLA MFR CABLES 125 156 FLA GEN J J J J J ATS 480V, 600A, 3P MTS 480V, 600A, 3P 480V, 3PH, 4W 250KW, 0.8PF GEN PORTABLE GENERATOR (BY CONTRACTOR) 30A 25A POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 5 0 P M 16 SINGLE LINE DIAGRAM - E-6 DPH JRM - DEMO AND REVISED SINGLE LINE DIAGRAM - DEMOLITION SINGLE LINE DIAGRAM - REVISED SHEET KEYNOTES A.CONTRACTOR SHALL DEMOLISH EXISTING ATS AND GENERATOR. CONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING CONDUCTORS IN CONDUITS 103, 104, AND 105. EACH CONDUIT IS 2-3" EACH WITH 3#350MCM & 1#1GND. B.CONTRACTOR SHALL DISCONNECT AND REMOVE CABLES IN CONDUITS 104 AND INTERCEPT AND RE-ROUTE EXISTING CONDUITS 104 TO NEW MANUAL TRANSFER SWITCH. CONTRACTOR SHALL ROUTE CONDUIT 104A (2-3" CONDUITS) FROM NEW MTS TO EXISTING DUCTBANK AND TIE BACK IN TO THE EXISTING POWER CONDUIT 104 (2-3" CONDUITS). CONDUIT 104A WILL BE THE CONDUIT TAG FOR THE RACEWAYS SYTEM BETWEEN MTS AND GENERATOR. AFTER CONDUITS ARE RE-ROUTED AND SUCCESSFULLY MANDRELED, CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT 2 SETS OF 3#350MCM & 1#1GND BETWEEN THE EXISTING ATS AND NEW MTS. CONTRACTOR SHALL PROVIDE SUFFICIENT SLACK IN CONDUCTORS AT THE EXISTING ATS TO TERMINATE TO NEW ATS ONCE ITS REPLACED. WIRE COMPLETE IN ACCORDANCE WITH NEC AND LOCAL CODES. C.DURING CONSTRUCTION, THE CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT A 250KW TEMPORARY GENERATOR TO THE MTS AND PROVIDE A BACKUP POWER SOURCE WHILE THE EXISTING GENERATOR IS BEING REPLACED. CONTRACTOR SHALL COORDINATE ALL PERMITTING AND PAY ALL ASSOCIATED FEES TO BRING A TEMPORARY SOURCE OF POWER TO THE SITE. 250AF 200AT 100KW LOAD BANK 104A 104 103 104 A A A 103 105 ZENITH MX200 C NEMA 4 GENERATOR RECEPTACLE AND MOUNTING BOX. 480V, 400A, 3W, 4P. APPLETON POWERTITE SERIES PIN AND SLEEVE CONNECTION. MODEL AJA40034-400N4-RS OR APPROVED EQUAL 10 4 B 105 B DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 5 0 P M 17 PANELBOARD SCHEDULE E-7 DPH JRM - PANEL PB-2 FED FROM: MCC 240 /120 VOLTS, SINGLE PHASE, 3 WIRE BUS: 125A AIC: 10KA MAIN: 100A/2P MOUNTING: INSIDE MCC CKT. NO.DESCRIPTION CONNECTED KVA TRIP AMPS/ POLES CKT. NO.DESCRIPTION CONNECTED KVA TRIP AMPS/ POLESABAB 1 PUMP ROOM EXHAUST FAN 1.13 20/1 2 CHEM FDR 0.70 20/1 3 SPARE 0.00 20/1 4 CHEM FDR 0.70 20/1 5 GENERATOR EXHAUST FAN 0.05 20/1 6 SPARE 0.00 20/1 7 GENERATOR HEATER 2.50 30/1 8 GENERATOR ROOM RECEPT 0.36 20/1 9 GENERATOR WATER HEATER 0.20 20/1 10 OUTSIDE RECEPT 0.72 20/1 11 BATTERY CHARGER 0.30 20/1 12 GENERATOR ROOM LIGHTS 0.42 20/1 13 METER VAULT 0.60 20/1 14 OUTSIDE LIGHTS 0.20 20/1 15 DRY WELL EXHAUST FAN 0.50 20/2 16 CHEM AREA LIGHTS 0.42 20/1 17 0.00 18 EM LIGHTS 0.05 20/1 19 SPARE 0.00 20/2 20 CHEM ROOM EXHAUST FAN 1.00 20/1 21 0.50 22 SPARE 20/1 23 SPACE 24 SPARE 20/1 25 SPACE 26 SPARE 20/1 27 SPACE 28 SPARE 20/1 29 SPACE 30 SPARE 20/1 PHASE SUBTOTALS (KVA):2.48 3.30 1.7 2.9 PHASE TOTALS (KVA):4.1 6.2 TOTAL KVA:10.3 KVA TOTAL AMPERES:43 A DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 M POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 5 0 P M 18 GENERATOR BUILDING E-8 DPH JRM - DEMOLITION AND MODIFIED PLANS SCALE: 3/8" = 1' GENERATOR BUILDING DEMOLITION PLAN SHEET KEYNOTES A.CONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING CABLES IN CONDUITS 119 (4#14 & 1#14GND BETWEEN ATS AND GENERATOR CONTROL PANEL), 120 (14#14 & 1#14GND BETWEEN MCP AND GENERATOR CONTROL PANEL) AND PB2(7,9,11) (BETWEEN PANELBOARD PB-2 AND GENERATOR AUXILIARY COMPONENTS). CONTRACTOR SHALL PROTECT IN PLACE THE EXISTING CONDUITS TO BE UTILIZED WITH NEW GENERATOR. SEE SHEET E-9 FOR LOCATION OF EXISTING MCP AND ATS. B.CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT NEW CONDUCTORS IN CONDUITS 118 (CAT6 ETHERNET CABLE BETWEEN GENERATOR CONTROL PANEL AND MCP), 119 (4#14 & 1#14GND BETWEEN NEW ATS AND NEW GENERATOR CONTROL PANEL), 120 (14#14 & 1#14GND BETWEEN MCP AND NEW GENERATOR CONTROL PANEL) AND PB2(7,9,11) BETWEEN PANELBOARD PB-2 AND GENERATOR AUXILIARY COMPONENTS (JACKET HEATER, BATTERY CHARGER AND WINDING HEATER). SEE SHEET E-9 FOR LOCATION OF MCP AND NEW ATS. C.CONTRACTOR SHALL INTERCEPT EXISTING DUCTBANK AND ROUTE CONDUIT 104A (2-3" CONDUITS EACH WITH A WIRE FILL OF 3#350MCM AND 1#1 GND) BETWEEN THE NEW MTS AND THE NEW GENERATOR. CONTRACTOR SHALL WIRE COMPLETE IN ACCORDANCE WITH THE NEC AND LOCAL CODES. D.CONTRACTOR SHALL EXTEND EXISTING CONDUIT STUBUP PB2-7,9,11 TO GENERATOR HEATERS AND BATTERY CHARGER. CONTRACTOR SHALL ROUTE NEW CONDUCTORS (2#10, 4#12 AND 1#10 GND) TO GENERATOR ANCILLARY DEVICES. WIRE COMPLETE IN ACCORDANCE WITH THE NEC AND LOCAL CODES. E.CONTRACTOR SHALL MODIFY EXISTING CONDUIT PB-2-5 TO NEW EXHAUST FAN LOCATION IF NECESSARY. CONTRACTOR SHALL PULL NEW CONDUCTORS (2#12 & 1#12 GND) FROM EXISTING PANELBOARD PB2 TO NEW EXHAUST FAN LOCATION. WIRE COMPLETE IN ACCORDANCE WITH THE NEC AND LOCAL CODES. F.CONTRACTOR SHALL PROTECT EXISTING GENERATOR PAD IN PLACE DURING REPLACEMENT OF EXISTING GENERATOR SET. G.CONTRACTOR SHALL PROTECT IN PLACE THE EXISTING GROUND RING AROUND THE GENERATOR BUILDING WHILE TRENCHING CONDUIT TO AND FROM THE MANUAL TRANSFER SWITCH. EXISTING CONDUIT PB2 (7, 9, 11) WITH EXISTING CONDUCTORS AND SPARE CONDUIT 118 EXISTING CONDUIT 104, 119, AND 120 WITH EXISTING CONDUCTORS AND SPARE CONDUIT 118 SEE SHEET E-5 FOR CONTINUATION A A SCALE: 3/8" = 1' GENERATOR BUILDING MODIFIED PLAN SEE SHEET E-5 FOR CONTINUATION EXISTING CONDUIT 104A, 118, 119, AND 120 WITH NEW CONDUCTORS B NEW CONDUIT 104A WITH NEW CONDUCTORS C E-4 4 E-4 1 E-4 3 GENERATOR CONTROL PANEL RADIATOR MOUNTED LOAD BANK PANELBOARD PB-2 EXISTING CONDUIT PB2-7, 9, 11 D GENERATOR AND LOAD BANK CIRCUIT BREAKERS NEW EXHAUST FAN E 1.GENERATOR ROOM HAS 2+ INCHES OF RIGID INSULATION ON WALLS AND CEILING. PROVIDE STRUT FOR DEVICES AND CONDUITS SUPPORTS OF SUFFICIENT DEPTH TO CLEAR. GENERAL SHEET NOTES F G SEE SHEET E-5 FOR CONTINUATION DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 5 0 P M 19 ELECTRICAL ROOM E-9 DPH JRM - DEMOLITION AND MODIFIED PLANS SCALE: 3/8" = 1' ELECTRICAL ROOM MODIFIED PLAN SHEET KEYNOTES A.CONTRACTOR SHALL DISCONNECT AND REMOVE POWER CONDUCTORS IN CONDUITS 103 (2-3" CONDUITS EACH WITH 3#350MCM & 1#1GND) AND 105 (2-3" CONDUIT EACH WITH 3#350MCM & 1#1GND). CONTRACTOR SHALL DISCONNECT NEWLY INSTALLED POWER CONDUCTORS IN CONDUIT 104 (2-3"C EACH WITH 3#350MCM & 1#1 GND). CONTRACTOR SHALL DISCONNECT AND REMOVE CONTROL CONDUCTORS IN CONDUIT 122 (3/4" WITH 4#14 & 1#14GND). CONTRACTOR SHALL REMOVE EXISTING ATS AND REPLACE WITH NEW ATS AT THE SAME LOCATION. B.ONCE THE NEW ATS IS SECURED TO EQUIPMENT PAD, CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT NEW CONDUCTORS (2 SETS OF 3#350MCM & 1#1 GND) IN EXISTING CONDUITS 103 AND 105, NEW CONDUCTORS (4#14 & 1#14GND) IN EXISTING CONDUIT 122 AND RECONNECT EXISTING NEWLY INSTALLED CONDUCTORS (2 SETS OF 3#350MCM & 1#1 GND) IN CONDUIT 104 TO THE ATS. WIRE COMPLETE IN ACCORDANCE WITH THE NEC AND LOCAL CODES. C.CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT NEW CONDUCTORS IN CONDUITS 118 (CAT6 ETHERNET CABLE BETWEEN GENERATOR CONTROL PANEL AND MCP), 119 (4#14 & 1#14GND BETWEEN NEW ATS AND NEW GENERATOR CONTROL PANEL), 120 (14#14 & 1#14GND BETWEEN MCP AND NEW GENERATOR CONTROL PANEL) AND PB2(7,9,11) BETWEEN PANELBOARD PB-2 AND GENERATOR AUXILIARY COMPONENTS (JACKET HEATER, BATTERY CHARGER AND WINDING HEATER). SEE SHEET E-9 FOR LOCATION OF MCP AND NEW ATS. 1.CONTRACTOR SHALL SUCCESSFULLY MANDREL ALL EXISTING CONDUITS PRIOR TO INSTALLATION OF NEW CONDUCTORS. GENERAL SHEET NOTES SCALE: 3/8" = 1' ELECTRICAL ROOM DEMOLITION PLAN SEE SHEET E-5 FOR CONTINUATION MAIN CONTROL PANEL (MCP) EXISTING CONDUITS 118, 120, AND 122 WITH NEW CONDUCTORS B MOTOR CONTROL CENTER (MCC) EXISTING CONDUITS 118 AND 120 WITH NEW CONDUCTORS B EXISTING CONDUIT 103 WITH NEW CONDUCTORS B NEW 600A ATS IN NEMA 1 GASKETED ENCLOSURE EXISTING CONDUITS 118, 120, AND 122 A EXISTING CONDUIT 105 A EXISTING CONDUIT 103 A E-4 2 SEE SHEET E-5 FOR CONTINUATION EXISTING CONDUIT 122 WITH NEW CONDUCTORS EXISTING CONDUIT 105 WITH NEW CONDUCTORS B B EXISTING CONDUITS 104 AND 119 WITH NEW CONDUCTORS B C C C DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 18 " 3" RED WARNING TAPE TRENCH BACKFILL COMPACTED TO 95% RELATIVE COMPACTION CONCRETE ENCASEMENT W/RED DYE 1. THIS DETAIL TYPICAL FOR NEW OR EXISTING CMU WALLS. 2. PREFORMED CHANNEL, FITTINGS AND CLAMPS SHALL BE STAINLESS STEEL. 3. CHANNELS TO BE SPACED AT 5'-0" OC MAXIMUM. 4.SUPPORT NOT TO EXCEED 15PLF COMBINED WEIGHT OF CONDUIT SYSTEM. NOTES: CONDUIT CLAMPS WITH SS BOLTS, NUTS, AND WASHERS (2) 1/2" DIAMETER X 3.25" EMEDMENT SST MASONRY ANCHORS (HILTI KWIK BOLT-TZ2 OR APPROVED EQUAL) WITH SST CHANNEL NUTS AND LOCK WASHERS ELEVATION AS R E Q U I R E D 6" M I N 1 5/8" SLOTTED STAINLESS STEEL STRUT CHANNEL NEW OR EXISTING CMU WALL 5' - 0 " M A X . RIGID STEEL/PVC COATED CONDUIT RISER. RIGID STEEL/PVC COATED CONDUIT COUPLING AND PLUG FOR SPARE CONDUIT. PROVIDE RIGID STEEL/PVC COATED CONDUIT RISER AS REQUIRED FOR DEEPER CONDUITS. FINISHED FLOOR/GRADE RIGID STEEL/PVC COATED CONDUIT ELBOW PVC CONDUIT, SIZE AS REQUIRED ON DRAWINGS 6" M I N CAP SCREWS PROVIDE CONDUIT SEAL IN WALL AND FLOOR WHERE PENETRATION ARE BELOW GRADE OR GROUND WATER LEVEL AND ENTERING INTO WATER CONTAINMENT RESERVOIR. MFR: O-Z/GEDNEY, TYPE FSK PRESSURE CLAMP SEALING RING CONDUIT OVERSIZE SLEEVE PRESSURE RINGS & SEALING GROMMET NOTES: WALL BODY 104A 5" ASPHALT CONCRETE FINISH COURSE. 3" 3" (TYP) 29" 6" CLASS II BASE COURSE. 30 " 104A 104 104 #4/0 BARE COPPER WIRE 1' - 6 " M I N I M U M 4" M I N ( T Y P ) 1. CONTRACTOR SHALL INSTALL AC SURFACE COURSE, AC BASE COURSE AND AGGREGATE BASE ROCK IN ACCORDANCE WITH CITY STANDARD DRAWINGS GS-24 THROUGH GS-28. NOTES: AGGREGATE BASE POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) No. E18977 Exp. 12/31/23 Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 5 1 P M 20 STANDARD ELECTRICAL DETAILS E-10 DPH JRM - - 1 TYPICAL UNREINFORCED DUCT BANK SCALE: NTS - 2 CONDUIT SUPPORT DETAIL SCALE: NTS - 3 PVC CONDUIT STUB-UP SCALE: NTS - 4 CONDUIT SEAL SCALE: NTS DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) ZACHARY D. HARRIS No. M28906 Exp. 6/30/24 M E C H A N I C A L Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 4 : 0 0 P M 21 GENERATOR BUILDING M-1 RJ ZH - DEMOLITION AND MODIFIED PLANS/ SECTION - 1 CHEMICAL ROOM BLOWER ROOM 1' - 1 1 " FLEXIBLE DUCT CONNECTOR GENERATOR ROOM LOAD BANK DUCT INCREASER W/ACOUSTIC LINER 1' - 8 " 6" EXTRUDED ALUMINUM LOUVER (16"W X 16" H) 6" EXTRUDED ALUMINUM LOUVER (16"W X 16" H) STANDBY ENGINE/GENERATOR 400 - GALLON SUB-BASE FUEL TANK (E) CONCRETE INERTIA PAD 11 ' - 0 " + / - 8" EXHAUST PIPING PLUS INSULATION 8" EXHAUST SILENCER FLEXIBLE DUCT CONNECTOR LOAD BANK 4' - 4 " 4" 1'-0" 8" EXHAUST PIPING PLUS INSULATION 8" EXHAUST SILENCER (CRITICAL GRADE) 12" ACOUSTIC LOUVER (72"W X 108"H) 24 " 6"36 " 10'-11" FLEXIBLE DUCT CONNECTOR (9" LENGTH) INLINE CENTRIFUGAL EXHAUST FAN 12"x8" OVAL DUCT DN M2 2 INLINE CENTRIFUGAL EXHAUST FAN 12"x8" OVAL DUCT ELECTRICAL STUB-UP AREA 400 - GALLON SUB-BASE FUEL TANK ASSEMBLY TANK VENT/ FUEL SUPPLY / INSTRUMENTATION CONNECTIONS 4' - 0" (E) VENT PIPE THROUGH (E) WALL PENETRATION (N) PIPE PENETRATION @ 15' - 6" AFF NORMAL TANK VENTS (2 PIPES) (E) SOUND ATTENUATOR SUPPORT (E) WALL THIMBLE - 1 GENERATOR BUILDING SECTION SCALE: 3/8" = 1' ELECTRICAL STUB-UP AREA T15S PIPE SUPPORT SEE DETAIL SHEET M-2 M2 4 DEMO EXISTING SHUTTER FAN ASSEMBLY E DEMO EXISTING EXHAUST PIPE B DEMO EXISTING ENGNE/GENERATOR ASSEMBLY A DEMO EXISTING SOUND ATTENUATOR C DEMO EXISTING ACOUSTIC LOUVER D SCALE: 3/8" = 1' GENERATOR BUILDING PLAN SCALE: 3/8" = 1' GENERATOR BUILDING DEMOLITION PLAN 10'-5" CONCRETE INERTIA PAD 2 1 / 2 " 2 1 / 2 " M2 3 F M2 5 G VERTICAL DUCT SUPPORT TYP SHEET KEYNOTES A.SALVAGE ENGINE/GENERATOR AND SUB-BASE FUEL TANK DURING REMOVAL FROM BUILDING. SHEAR FUEL TANK ANCHORAGE BOLTS LEVEL WITH CONCRETE INERTIA PAD. B.DEMOLISH EXHAUST SILENCER AND EXHAUST PIPING UPSTREAM OF EXHAUST SILENCER. REMOVE EXHAUST PIPING DOWNSTREAM OF SILENCER TO A POINT 24 INCHES FROM INTERIOR WALL. DEMOLISH EXHAUST PIPE INSULATION SYSTEM. DEMOLISH PIPE HANGERS. RETAIN UPPER ATTACHMENT OF HANGER SYSTEM TO STRUCTURE. C.DEMOLISH EXISTING SOUND ATTENUATOR AND TRANSITION DUCTWORK TO ENGINE/GENERATOR ASSEMBLY. RETAIN CMU SOUND ATTENUATOR SUPPORT. PROVIDE PLYWOOD COVER (3/4” OSB) OVER SOUND ATTENUATOR SUPPORT OPENING. D.DEMOLISH EXISTING LOUVER. PROVIDE TEMPORARY PLYWOOD COVER (3/4” OSB) OVER EXISTING WALL OPENING. E.DEMOLISH EXISTING WALL EXHAUST FAN ASSEMBLY AND LOUVER. PROVIDE TEMPORARY PLYWOOD COVER (3/4” OSB) OVER EXISTING WALL OPENING. RETAIN EXISTING CONDUIT FOR NEW POWER SUPPLY WIRING TO REPLACEMENT FAN. (REFER TO ELECTRICAL DRAWINGS) F.DESIGN POINT: 400 FM @ 0.15 INCH W.C.; LEFT DISCHARGE (SIDE OUTLET) CONFIGURATION; DIRECT DRIVE ASSEMBLY, 120 VAC, 1-PHASE, 60 HZ MOTOR. PROVIDE VERTICAL HANGING NEOPRENE ISOLATORS; CONTINUOUS OPERATION, PROVIDE MANUAL DIAL SPEED CONTROL ACCESSORY. GREENHECK SQ-90, OR EQUAL. G.PROVIDE EXTRUDED ALUMINUM LOUVER, 6-INCH DEPTH, CHANNEL FRAME FOR MOUNTING IN EXISTING WALL OPENING. H.MOUNT ADHESIVE SIGNS ON ENGINE-GENERATOR AND FUEL TANK ASSEMBLY AT DIRECTION OF EQUIPMENT SUPPLIER. I.MOUNT "DANGER - COMBUSTIBLE LIQUIDS" AND "DANGER - NO SMOKING" SIGNS VERTICALLY ABOVE ONE ANOTHER IN LOCATION SHOWN. MOUNT ADDITIONAL HAZARD ALERTING SIGNAGE ON NORTH WALL OF BUILDING. NFPA 704 DIAMOND SIGN 'BATTERY ACID' NFPA 704 DIAMOND SIGN 'DIESEL' TANK LABEL 'DIESEL' H H HAZARD ALERTING SIGNAGE I (E) FIRE EXTINGUISHER H 1.CONSTRUCTION AND DEMOLITION OPERATIONS SHALL INCORPORATE SALVAGE AND/OR RECYCLING OF MATERIALS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, AS ADOPTED BY THE CITY OF CARLSBAD. 2.POLLUTION CONTROL LIMITS FOR THE SELECTION OF FINISH MATERIALS SHALL BE IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, AS ADOPTED BY THE CITY OF CARLSBAD. GENERAL SHEET NOTES DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 2" M I N . POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) ZACHARY D. HARRIS No. M28906 Exp. 6/30/24 M E C H A N I C A L Us e r : ER I C K A L M A L E L Pl o t D a t e : 11 / 2 7 / 2 0 2 3 3 : 5 2 P M 22 GENERATOR BUILDING M-2 DPH JRM - MECHANICAL DETAILS - 1 T15S PIPE SUPPORT N.T.S.- 2 GENERATOR ROOM EXHAUST - SECTION SCALE: 1/2" = 1' 16"x16" WALL OPENING W/ LOUVER IN-LINE CENTRIFUGAL EXHAUST FAN (LEFT DISCHARGE) 12" X 8" OVAL DUCT 45° MITERED INLET OVAL MITERED ELBOW OVAL-RECTANGULAR DUCT TRANSITION CMU WALL 2" ACOUSTIC WALL INSULATION - 3 INLINE EXHAUST FAN SCALE: 1/2" = 1' - 4 PIPE PENETRATION N.T.S. VERTICAL SUPPORT THREADED RODS, SEE DETAIL 2 ON DRAWING SHEET S-2, SIMILAR (TYP OF 4) FLEXIBLE DUCT CONNECTION (TYP) EXHAUSTEXHAUST FAN SPRING TYPE VIBRATION ISOLATOR (TYP 4) EXHAUST FAN BRACKETS PER MANUFACTURER (E) CMU WALL 1/2" BOLT, NUT AND WASHER (TYP 2) (4) 3/4" DIAMETER X 3.75" EMBEDMENT WITH HILTI KWIK-BOLT-TZ2 OR APPROVED EQUAL PLATE 3/4" x 9" x 9" GROUT OR DRYPACK 3/4" MIN, 1" MAX FLOOR 1/4 TS3 x 3 x 0.25 UNISTRUT P2542 TO 2546 AS REQ'D, OR EQUIVALENT ANVIL-STRUT OR B-LINE PRODUCTS 1/8 13/16" PLATE 4 INCH CORE BIT DRILL OPENING INTERIOR SIDEEXTERIOR SIDE NOTE 1.OPENING DIMENSION AND MECHANICAL SEAL INSTALLATION SHALL BE PER MFR'S. RECOMMENDATION. 2" NORMAL VENT PIPE MODULAR MECHANICAL EXPANDING RUBBER SEAL (E)CMU WALL - 5 VERTICAL DUCT SUPPORT N.T.S. CMU WALL, BEHIND ACOUSTIC WALL COVERING 3/4" DIAMETER X 3.75" EMBEDMENT WITH HILTI KWIK-BOLT-TZ2 OR APPROVED EQUAL. ONE ANCHOR EACH SIDE, SEE NOTES #8 GALV SHEET MTL TAPPING SCREW, TYP 3 SIDES 1 1/2" x 16 GA STRAP SEE NOTES 1 AND 2 OVAL DUCT NOTES 1.SECURE DUCT AT 2 FEET AND AT 7 FEET FROM FLOOR. 2.LOCATE DUCTS TIGHT AGAINST ACOUSTIC WALL COVERING. 3.EACH WALL ANCHOR SHALL SATISFY THE FOLLOWING 4.LOCATE AND AVOID ALL REINFORCEMENT PRIOR TO DRILLING INTO THE MASONRY. 5.FOLLOW ICC ESR-4561 FOR INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS. 6.ALTERNATE OR APPROVED EQUAL ANCHORS SHALL HAVE A CURRENT AND RELATIVE ICC-ESR OR IAPMO REPORT, AND SHALL BE SUBMITTED FOR REVIEW PRIOR TO USE. NOTES: 1.CAREFULLY REMOVE ALL EXISING CEILING INSUALTION AND REPLACE WITH NEW OR RE-USE EXISTING INSULATION PENDING CITY APPROVAL. 2.DO NOT DAMAGE OR CUT ANY EXISTING FRAMING OR BLOCKING. 3.ALIGN SUPPORTS TO EXISTING FRAMING OR BLOCKING. WHERE EXISING FRAMING IS OFFSET, INSTALL 2X8 BLOCKING (DOUGLASS-FIR #2) WITH SIMPSON A34 CLIPS AT EACH END (OR APPROVED EQUAL). 4.REFERENCE DETAIL 2 ON DRAWING SHEET S-2 FOR INFORMATION NOT SHOWN. ATTACHMENT TO ROOF FRAMING PER DETAIL 2 ON DRAWING SHEET S-2 (TYP) LATERAL BRACE (ONE IN EACH DIRECTION), SEE DETAIL 2 ON DRAWING SHEET S-2, SIMILAR NOTES: 1.LOCATE AND AVOID ALL REINFORCEMENT PRIOR TO DRILLING INTO THE CONCRETE. 2.FOLLOW ICC ESR-4266 FOR INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS. 3.ALTERNATE OR APPROVED EQUAL ANCHORS SHALL HAVE A CURRENT AND RELATIVE ICC-ESR OR IAPMO REPORT, AND SHALL BE SUBMITTED FOR REVIEW PRIOR TO USE. 6" M I N 12 " M A X DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 23 STRUCTURAL GENERAL NOTES, S-1 ABBREVIATIONS, & SPECIAL INSPECTIONS PIB PDS - POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) STRUCTURAL DESIGN CRITERIA STRUCTURAL ABBREVIATIONS 1.DESIGNED IN ACCORDANCE WITH THE 2022 CALIFORNIA BUILDING CODE, INCLUDING LATEST REVISIONS, AND ASCE 7-16, EXCEPT WHERE OTHER APPLICABLE CODE OR THE FOLLOWING NOTES ARE MORE RESTRICTIVE. 2.LIVE LOADS: ROOF, BUILDING (REDUCIBLE)20 PSF, 300 LBS POINT 3.WIND DESIGN DATA: BASIC WIND SPEED, VULT 102 MPH NOMINAL WIND SPEED, VASD 79 MPH RISK CATEGORY III EXPOSURE B INTERNAL PRESSURE COEFFICIENT +/- 0.18 COMPONENTS & CLADDING PRESSURE NOT APPLICABLE (INTERIOR CONDITION) 4.SNOW DESIGN DATA: NOT APPLICABLE 5.SEISMIC DESIGN DATA: THE SEISMIC DESIGN PARAMETERS HAVE BEEN DEVELOPED IN ACCORDANCE WITH THE 2022 CALIFORNIA BUILDING CODE AND ASCE 7-16 INCLUDING SUPPLEMENT NO. 3, CONSIDERING EXCEPTION 2 OF SECTION 11.4.8 OF ASCE 7-16, WHERE A SITE-SPECIFIC GROUND MOTION PROCEDURE IS NOT REQUIRED. RISK CATEGORY III SEISMIC IMPORTANCE FACTOR, IE 1.25 SEISMIC IMPORTANCE FACTOR, Ip 1.00 MAPPED RESPONSE PARAMETER (SHORT), SS 0.959g MAPPED RESPONSE PARAMETER (1-SEC), S1 0.351g SITE CLASS D DESIGN RESPONSE PARAMETER (SHORT), SDS 0.767g DESIGN RESPONSE PARAMETER (1-SEC), SD1 0.684g SEISMIC DESIGN CATEGORY D LONG PERIOD TRANSITION PERIOD, TL 8 SECONDS BASIC SEISMIC-FORCE-RESISTING SYSTEM GENERATOR SEISMIC RESPONSE COEFFICIENT, Fp 5.91 KIPS COMPONENT AMPLIFICATION FACTOR, ap 1.0 RESPONSE MODIFICATION COEFFICIENT, Rp 2.5 ANALYSIS PROCEDURE CHAPTER 13 OF ASCE 7-16 6.FLOOD DESIGN DATA: NOT APPLICABLE STRUCTURAL NOTES, SPECIAL INSPECTION AND TESTING TABLES EXISTING STRUCTURE REFERENCE DOCUMENTS THE EXISTING CONDITIONS SHOWN ON THESE CONTRACT DOCUMENTS ARE DEVELOPED FROM THE AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO PROCEEDING WITH ANY DEMOLITION, ORDERING, OR FABRICATING ANY MATERIALS. IF RECORD DRAWINGS ARE AVAILABLE, AND AVAILABLE FOR DISTRIBUTION, OBTAIN A COPY PRIOR TO CONSTRUCTION. DURING CONSTRUCTION, THE CONTRACTOR SHALL NOT ALTER, DAMAGE, OR REMOVE ANY PORTIONS OF THE EXISTING STRUCTURE (INCLUDING NONSTRUCTURAL COMPONENTS) UNLESS SPECIFICALLY INDICATED ON THESE CONSTRUCTION DOCUMENTS. RECORD DRAWINGS USED TO DEVELOP THESE CONTRACT DOCUMENTS: DRAWING TITLE:PLANS FOR THE CONSTRUCTION OF THE POINSETTIA SEWAGE LIFT STATION IN THE CARLSBAD MUNICIPAL WATER DISTRICT ENGINEER OF RECORD:WILSON ENGINEERING CONSULTING ENGINEERS DATE OF RECORD:1999 &AND @ AT #NUMBER Ø DIAMETER ld DEVELOPMENT LENGTH AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY TRANSPORTATION OFFICIAL AB AGGREGATE BASE, ANCHOR BOLT ACI AMERICAN CONCRETE INSTITUTE ADD ADDITIONAL ADJ ADJACENT AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE AITC AMERICAN INSTITUTE OF TIMBER CONSTRUCTION ALUM ALUMINUM ALT ALTERNATE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APA AMERICAN PLYWOOD ASSOCIATION APROX APPROXIMATE ARCH ARCHITECTURAL ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS AWS AMERICAN WELDING SOCIETY AWWA AMERICAN WATER WORKS ASSOCIATION B/BOTTOM OF BLKG BLOCKING BLDG BUILDING BM BEAM BM-1 BEAM MEMBER 1 BN BOUNDARY NAILING BOT BOTTOM BP BASE PLATE C CHANNEL CC,C/C CENTER-TO-CENTER CBC CALIFORNIA BUILDING CODE CIP CAST IN PLACE CJ CONSTRUCTION JOINT CJP COMPLETE JOINT PENETRATION CENTERLINE CLSM CONTROLLED LOW STRENGTH MATERIAL CLR CLEAR CNJ CONTROL JOINT COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS DBL DOUBLE DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DN DOWN DWG(S)DRAWINGS (E)EXISTING EA EACH EF EACH FACE EL ELEVATION ELEC ELECTRICAL EMBED EMBEDMENT EN EDGE NAILING EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE EW EACH WAY EXP EXPANSION EXT EXTERIOR (F)FUTURE FD FLOOR DRAIN FF FINISH FLOOR FLR FLOOR FN FIELD NAILING FNDN FOUNDATION FRP FIBERGLASS REINFORCED PLASTIC FS FAR SIDE FT FOOT/FEET FTG FOOTING GA GAGE/GAUGE GALV GALVANIZED GLB GLULAM BEAM HDG HOT DIP GALVANIZE(D) HORIZ HORIZONTAL HSS HOLLOW STRUCTURAL SECTION HT HEIGHT HWL HIGH WATER LEVEL IBC INTERNATIONAL BUILDING CODE ICC INTERNATIONAL CODE COUNCIL IN INCH INT INTERIOR JT JOINT KIP 1,000 POUNDS KSI KIPS PER SQUARE INCH L,∠ ANGLE LB(S) POUNDS LB/SF POUND(S) PER SQUARE FOOT LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LLBB LONG LEG BACK-TO-BACK LONGIT LONGITUDINAL LT LIGHT LW LIGHT WEIGHT MATL MATERIAL MAX MAXIMUM MB MACHINE BOLT MC MOISTURE CONTENT MC MISCELLANEOUS CHANNEL MECH MECHANICAL MIN MINIMUM MISC MISCELLANEOUS MSE MECHANICALLY STABILIZED EARTH N/A NOT APPLICABLE (N) NEW NDT NON-DESTRUCTIVE TEST(ING) NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NO. NUMBER NOM NOMINAL NS NEAR SIDE NSG NON-SHRINK GROUT NTS NOT TO SCALE OC ON CENTERS OD OUTSIDE DIAMETER OH OPPOSITE HAND, OVERHEAD OPNG(S) OPENING(S) OPP OPPOSITE OSHA OCCUPATIONAL SAFETY AND HEALTH ASSOCIATION PAF POWDER/POWER ACTUATED FASTENER PER PERIODIC PEMB PRE-ENGINEERED METAL BUILDING PL PLATE PLF POUND PER LINEAL FOOT PP PARTIAL PENETRATION PSF POUND PER SQUARE FOOT PSI POUND PER SQUARE INCH PT(S) POINT(S) PT PRESSURE TREATED R, RAD RADIUS RECT RECTANGLE, RECTANGULAR REINF REINFORCING, -MENT REQ'D REQUIRED SCH SCHEDULE SF SQUARE FOOT SHT SHEET SIM SIMILAR SLBB SHORT LEGS BACK-TO-BACK SLH SHORT LEG HORIZONTAL SLV SHORT LEG VERTICAL SMS SHEET METAL SCREW SPEC(S) SPECIFICATION(S) SQ SQUARE SS STAINLESS STEEL SSD SATURATED SURFACE DRY STAG STAGGER STD STANDARD STIFF STIFFENER STL STEEL STRUC STRUCTURE SUSP SUSPENDED SYM SYMMETRICAL T/ TOP OF T&B TOP AND BOTTOM TS STRUCTURAL TUBING TYP TYPICAL UON UNLESS OTHERWISE NOTED UT ULTRASONIC TESTING VERT VERTICAL VIF VERIFY IN FIELD W/ WITH W/O WITHOUT W, WF WIDE FLANGE WCLIB WEST COAST LUMBER INSPECTION BUREAU WP WORK POINT WSTP WATERSTOP WT WEIGHT, STRUCTURAL TEE WALL THICKNESS WWF WELDED WIRE FABRIC YD YARD GENERAL 1.THE CONSTRUCTION SHALL CONFORM TO THE 2022 CALIFORNIA BUILDING CODE (CBC), AND THE APPLICABLE REFERENCED BUILDING CODE STANDARDS. 2.THESE NOTES AS WELL AS THE STANDARD DETAILS APPLY TO ALL PARTS OF THE PROJECT, UNLESS NOTED OTHERWISE. 3.SHOP DRAWINGS FOR THIS CONTRACT SHALL BE COORDINATED WITH FAVORABLY REVIEWED EQUIPMENT MANUFACTURER'S DRAWINGS. DIMENSIONS FOUNDATION DIMENSIONS ARE TO BE COORDINATED WITH FAVORABLY REVIEWED SUBMITTAL BY THE EQUIPMENT MANUFACTURER. 4.DETAILS CALLED OUT WITH S-XXXX SHALL REFER TO THE STANDARD DETAIL FOR WHICH THEY ARE SO NAMED. 5.ALL STRUCTURES HAVE BEEN DESIGNED FOR THE COMPLETE CONDITION CONSIDERING OPERATIONAL, HYDROSTATIC, BACKFILL LOADS, AND APPLICABLE DYNAMIC LOADS ONLY. THE STRUCTURES HAVE NOT BEEN DESIGNED TO RESIST OPERATIONAL, HYDROSTATIC OR BACKFILL LOADS WHILE PARTIALLY CONSTRUCTED. OVERLOADING ANY OF THE STRUCTURES OR STRUCTURAL ELEMENTS WHILE PARTIALLY CONSTRUCTED IS PROHIBITED. COMPLIANCE 1.OBTAIN ALL PERMITS AND COORDINATING ALL INSPECTIONS REQUIRED BY THE SPECIAL INSPECTOR AND AS DESCRIBED IN THE CONTRACT DOCUMENTS. 2.THE CONTRACTOR SHALL NOTIFY THE SPECIAL INSPECTOR AT LEAST (5) FIVE WORKING DAYS PRIOR TO EACH SPECIAL INSPECTIONS AND TESTING REQUIRED. THE CONTRACTOR SHALL PROVIDE ACCESS TO THE WORK REQUIRED FOR SPECIAL INSPECTIONS AND TESTING. 3.THE CONTRACTOR SHALL DESIGN, DETAIL, FABRICATE, INSTALL AND MAINTAIN SHORING, SHEETING, BRACING AND SLOPING AS NECESSARY TO MAINTAIN SAFE EXCAVATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING FULL COMPLIANCE WITH 29 CFR PART 1926 OSHA SUBPART P EXCAVATIONS AND TRENCHES REQUIREMENTS. ALL EARTHWORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH APPLICABLE LAW, INCLUDING LOCAL ORDINANCES, CAL/OSHA, HAWAII CIVIL CODE AND HAWAII DEPARTMENT OF INDUSTRIAL SAFETY REQUIREMENTS, AND APPLICABLE OSHA REQUIREMENTS. SOIL AND FOUNDATIONS 1.NO GEOTECHNICAL INVESTIGATION HAS BEEN PERFORMED FOR THIS PROJECT SITE. THE SOIL DESIGN VALUES USED FOR THE DESIGN OF THE FOUNDATION ARE CONSISTENT WITH THE ORIGINAL DESIGN INTENT AS PROVIDED ON THE RECORD DRAWINGS, AND THE PRESUMPTIVE LOAD-BEARING VALUES PER TABLE 1806.2 OF THE 2022 CALIFORNIA BUILDING CODE. 2.ALLOWABLE BEARING CAPACITY OF SOILS ARE REPORTED FOR DEAD AND LIVE LOADS ONLY. ALLOWABLE BEARING VALUES MAY BE INCREASED BY ONE-THIRD WHEN TRANSIENT LOADS SUCH AS WIND OR SEISMIC LOADS ARE INCLUDED. THE FOUNDATIONS DESIGN PARAMETERS ARE AS FOLLOWS: ALLOWABLE BEARING PRESSURE 1,500 PSF COHESION 130 PSF 3.EXCAVATE DOWN TO THE REQUIRED ELEVATIONS PRIOR TO BACKFILLING WITH COMPACTED FILL (SUBGRADE). NATIVE MATERIAL SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 6-INCHES, COMPACTED, AND TESTED TO 95% RELATIVE COMPACTION PER ASTM D1557. 4.SUBGRADE (COMPACTED FILL) SHALL BE CLASS 2 AGGREGATE BASE (AB). COMPACTED FILL AND NATIVE MATERIALS 12-INCHES OR LESS NEED NOT TO COMPLY WITH AN APPROVED GEOTECHNICAL REPORT PROVIDED THE IN PLACE DENSITY IS NOT LESS THAN 90% OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT DETERMINED IN ACCORDANCE WITH ASTM D1557. COMPACT TO 95% RELATIVE COMPACTION AS DETERMINED BY ASTM D1557. 5.COMPACTION OF NATIVE MATERIALS AND COMPACTED FILL MATERIALS SHALL BE VERIFIED BY THE SPECIAL INSPECTOR PER THE 2022 CBC, SECTION 1804.6 AND THE SPECIAL INSPECTION NOTES ON DRAWINGS. THE SPECIAL INSPECTOR SHALL BE INDEPENDENT OF THE CONTRACTOR. CONCRETE 1.CONCRETE MIX DESIGNS SHALL BE IN ACCORDANCE WITH ACI 318-19 AND ACI 301-16. THE MINIMUM 28-DAY COMPRESSIVE STRENGTH (PSI) AS NOTED IN THE TABLE BELOW: 2.MIX DESIGN : 3.CEMENTITIOUS MATERIALS : 4.AGGREGATE IN CONCRETE : 4.1.AGGREGATES SHALL BE CLEAN, AND CONFORM TO ASTM C33 AND THE TABLES BELOW. 4.2.AGGREGATES SHALL NOT BE REACTIVE. PROVIDE DOCUMENTATION THAT AGGREGATES HAVE BEEN VERIFIED TO BE NON-REACTIVE PER ASTM C1260. TEST RESULTS SHALL NOT BE OLDER THAN 1-YEAR, SUBMIT FOR REVIEW. 5.ADMIXTURES (OPTIONAL) : 6.OPENINGS, PIPE SLEEVES, CONDUITS, INSERTS AND OTHER EMBEDDED ITEMS SHALL BE IN PLACE BEFORE CONCRETE IS PLACED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE ELECTRICAL, INSTRUMENTATION AND OTHER PLANS FOR ITEMS REQUIRING SLEEVES AND EMBEDMENTS IN CONCRETE WHICH ARE NOT INDICATED OR SHOWN ON STRUCTURAL DRAWINGS. NO PIPES OR SLEEVES SHALL PASS THROUGH STRUCTURAL MEMBERS(UNLESS SHOWN ON STRUCTURAL DRAWINGS). COORDINATE WITH EQUIPMENT MANUFACTURERS DRAWINGS FOR ANCHORING DEVICES. 7.UNLESS OTHERWISE NOTED, ALL EXPOSED EDGES AND CORNERS SHALL BE CHAMFERED 3/4-INCH. INTERIOR FLOOR SLABS AND EXTERIOR SIDEWALKS SHALL HAVE TOOLED 3/8-INCH RADIUS CONSTRUCTION JOINT. 8.PROVIDE TROWEL FINISH AT HORIZONTAL SURFACES IN ACCORDANCE WITH ACI 301. 9.FOUNDATIONS SHALL BE PER THE CONTRACT DOCUMENTS. IF NOT SHOWN, EACH FACE CONCRETE SHALL BE REINFORCED WITH # 5 BARS AT 12-INCHES EACH WAY, UNLESS OTHERWISE NOTED. 10.CONCRETE ENCASE ALL PIPES AND CONDUITS UNDER CONCRETE SLABS, FOUNDATIONS, AND STRUCTURES. 11.CONCRETE SHALL BE PLACED AND CURED BETWEEN 50 AND 90 DEGREES F. CONCRETE SHALL NOT BE PLACED WHEN THE AMBIENT TEMPERATURE EXCEEDS 90 DEGREES F. 12.SUBMIT REINFORCEMENT SHOP DRAWINGS AND CONCRETE MIX DESIGN FOR REVIEW TO THE ENGINEER OF RECORD. REINFORCING STEEL (FOR CONCRETE) 1.REINFORCING STEEL (DEFORMED BARS) SHALL BE ASTM A615, GRADE 60. 2.ARRANGEMENT AND DETAILING OF REINFORCING STEEL, INCLUDING BAR SUPPORTS AND SPACERS, SHALL BE IN ACCORDANCE WITH THE LATEST ACI 315 DETAILING MANUAL AND CRSI. DO NOT PLACE REINFORCEMENT SUPPORTS GREATER THAN 36-INCHES ON-CENTER. 3.REINFORCING SHALL LAP IN ACCORDANCE WITH THE CONCRETE REINFORCEMENT SPLICE TABLE, UNLESS OTHERWISE SHOWN. DOWELS SHALL HAVE THE SAME SIZE AND SPACING AS THAT OF THE REINFORCING STEEL, UNLESS OTHERWISE NOTED. 4.HOOK REINFORCING BARS SHALL NOT BE INTERRUPTED BY OPENINGS. 5.NO WELDING OF REINFORCING BARS SHALL BE PERMITTED, UNLESS APPROVAL IN WRITING IS OBTAINED FROM THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION. 6.DIMENSIONS TO REINFORCING ARE TO BAR CENTERLINES, UNLESS NOTED OTHERWISE BAR COVER IS CLEAR DISTANCE BETWEEN THE BAR AND THE CONCRETE SURFACE. UNLESS NOTED OR SHOWN OTHERWISE BAR COVER FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND BASE SLABS (FOR CONCRETE): FORMED SURFACES AND BOTTOMS ON CONCRETE WORK MAT 2-INCH TOP SURFACES EXPOSED TO EARTH, WATER, OR WEATHER 2-INCH BOTTOMS AND SIDES IN CONTACT WITH EARTH 3-INCH SOILS SPECIAL INSPECTIONS AND TESTS OF EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT AND LOAD-BEARING REQUIREMENTS SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING. REQUIRED SPECIAL INSPECTIONS AND TESTS SPECIAL INSPECTION REQUIRED TYPE CONT PERIODIC YES 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.--X YES 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL.--X YES 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.--X YES 4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X -- YES 5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. --X CONCRETE COMPRESSIVE STRENGTH TABLE TYPE ID REQUIRED f ' c AT 28-DAYS LOCATION FOR USE W / CM A 4,000 PSI FOUNDATION, SLAB-ON-GRADE 0.50 MAX FIELD TEST RECORDS SUBMIT IN ACCORDANCE WITH CHAPTER 5.3 OF ACI 318 AIR CONTENT OPTIONAL: 4% +/- 1% IN ACCORDANCE WITH ASTM C231 SLUMP 3 TO 4 INCHES, MAX. TESTED IN ACCORDANCE WITH ASTM C143 MINIMUM CONTENT 520 LBS / CUBIC YARD PORTLAND CEMENT TYPE II (LOW ALKALI) PER ASTM C150 POZZOLAN CLASS F FLYASH PER ASTM C618. NOT TO EXCEED 15% OF TOTAL CEMENTITIOUS MATERIALS. POZZOLAN SUPPLIED DURING THE LIFE OF THE PROJECT SHALL BE FROM THE SAME SINGLE SOURCE. CLASS C FLYASH WILL NOT BE PERMITTED FOR USE. COARSE CONFORM TO TABLE 2 OF ASTM C33. THE NOMINAL MAXIMUM SIZE OF COARSE AGGREGATE SHALL NOT EXCEED THREE-FOURTHS OF THE MINIMUM CLEAR SPACING BETWEEN REINFORCING BARS, ONE-FIFTH OF THE NARROWEST DIMENSION, BETWEEN SIDES OF FORMS, AND ONE-THIRD OF THE THICKNESS OF SLABS OR WALLS. FINE CONFORM TO TABLE 1 OF ASTM C33 COMBINED AGGREGATE GRADATION (% PASSING SIEVE) 1-1/2"1"3/4"3/8"NO. 4 NO. 8 NO. 16 NO. 30 NO. 50 NO. 100 NO. 200 100 90 - 100 55 - 100 45 - 75 35 - 60 27 - 45 20 - 35 12 - 25 3 - 15 0 - 5 0 - 2 CONCRETE CONSTRUCTION REQUIRED SPECIAL INSPECTIONS AND TESTS SPECIAL INSPECTION REQUIRED TYPE CONT PERIODIC REFERENCED STANDARD (a) CBC REF YES 1. INSPECT REINFORCEMENT, INCLUDING SIZE AND GRADE, VERIFY PLACEMENT.--X ACI 318 Ch. 20, 25.2, 25.3, 26.6.1 - 26.6.3 19 0 8 . 4 YES 3. INSPECT ANCHORS CAST IN CONCRETE.--X ACI 318 17.8.2 -- 4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS. YES a. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS. X --ACI 318 17.8.2.4 -- YES b. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.a.--X ACI 318 17.8.2 YES 5. VERIFY USE OF REQUIRED DESIGN MIX.--X ACI 318 Ch. 19, 26.4.3, 26.4.4 1904.1 1904.2 1908.2 1908.3 YES 6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE CONCRETE. a.) COMPRESSIVE STRENGTH TESTS SHALL BE PERFORMED ON EACH 100 CUBIC YARDS OR FRACTION THEREOF, OF OF EACH CONCRETE MIX PLACED IN ANY ONE DAY, IN ACCORDANCE WITH ASTM C39. b. SLUMP TESTS SHALL BE PERFORMED ON EACH 50 CUBIC YARDS IN ACCORDANCE WITH ASTM C143. c. AIR CONTENT TESTED PER ASTM C231 OR ASTM C173, MADE WITH SAMPLES FROM FIRST THREE BATCHES AND UNTIL THREE BATCHES MEET AIR CONTENTS SPECIFIED. d. CONCRETE TEMPERATURE SHALL BE TESTED IN ACCORDANCE WITH ASTM C1064. X -- ASTM C172, ASTM C1064, ASTM C143, ASTM C31, ASTM C39, ACI 318 26.4, 26.12 19 0 8 . 1 0 YES 7. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.--X ACI 318 26.5.3 - 26.5.5 1908.9 YES 8. VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS. --X ACI 318 26.11.2 -- YES 9. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED, --X ACI 318 26.11.1.2(b)-- AIR ENTRAINING ASTM C260 WATER REDUCING ASTM C494, TYPE A CONDUIT COORDINATION 1.ELECTRICAL CONDUIT AND PIPES SHALL BE ENCASED BELOW STRUCTURE FOUNDATIONS. DO NOT PLACE CONDUIT OR PIPING INSIDE THE FOOTINGS, SLABS, OR FOUNDATION PARALLEL TO THE MAIN LONGITUDINAL REINFORCEMENT. 2.CONDUIT SHALL MAINTAIN A MINIMUM OF 2-INCHES CLEAR TO REINFORCEMENT. CONDUIT OR PIPES SHALL NOT BE SUPPORTED DIRECTLY ON REINFORCING STEEL. 2.REINFORCEMENT SHALL NOT BE CUT, BENT, OR RELOCATED. 3.CONDUIT RUNNING PARALLEL TO REINFORCEMENT: 3.1.THE OUTSIDE DIAMETER OF THE CONDUIT SHALL NOT EXCEED ONE-THIRD OF THE MEMBER THICKNESS. 3.2.CONDUIT SHALL NOT BE SPACED CLOSER THAN 3 OUTSIDE DIAMETERS ON CENTER. THE MAXIMUM CONDUIT SIZE SHALL BE USED TO DETERMINE THE SPACING BETWEEN THE CONDUIT. 3.3.CONDUIT SHALL BE LOCATED WITHIN THE MIDDLE THIRD OF THE FOUNDATION OR STRUCTURAL MEMBER, ONLY. 3.4.DEVIATIONS WILL NOT BE PERMITTED WITHOUT SPECIFIC REVIEW AND ACCEPTANCE BY THE STRUCTURAL ENGINEER OF RECORD. ALL CONDUIT EMBEDDED INTO STRUCTURAL MEMBERS, SLABS, OR FOUNDATIONS WITHOUT ANY REVIEW BY THE STRUCTURAL ENGINEER OF RECORD SHALL BE REMOVED AT THE CONTRACTORS EXPENSE. 4.CONDUIT RUNNING PERPENDICULAR TO REINFORCEMENT: 4.1.COORDINATE PLACEMENT TO AVOID OR MINIMIZE IMPACT TO REINFORCEMENT PLACEMENT. 4.2.GROUPS OF CONDUIT THAT DAYLIGHT TO THE EDGE OR TP OF FOUNDATIONS OR SLABS-ON-GRADE SHALL BE BLOCKED-OUT LIKE AN OPENING IN THE STRUCTURE. AROUND THE PERIMETER OF THE BLOCK-OUT, PROVIDE ADDITIONAL REINF WITH (2) #5 TRIM BARS, SPACED 2-INCHES APART, IN-PLANE WITH TYPICAL REINFORCEMENT ON ALL SIDES, LAP WITH TYPICAL REINFORCEMENT. 4.3.AT THE BLOCK-OUT: PROVIDE #5 DIAGONAL BARS AT EACH CORNER, LAP PAST EACH EDGE. BARS THAT TERMINATE AT SLAB EDGE SHALL HAVE A STANDARD HOOK. SPECIAL INSPECTION AND TESTING - GENERAL NOTES 1.THE OWNER OR THE OWNER'S AUTHORIZED AGENT, INDEPENDENT OF THE CONTRACTOR, SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND TESTING IN ACCORDANCE WITH CHAPTER 17 OF THE 2022 CALIFORNIA BUILDING CODE AND THE CONTRACT DOCUMENTS DURING CONSTRUCTION ON THE TYPES OF WORK SPECIFIED. STRUCTURAL SPECIAL INSPECTIONS AND TESTING SHALL GOVERN THE QUALITY, WORKMANSHIP AND REQUIREMENTS FOR MATERIALS COVERED. MATERIALS OF CONSTRUCTION AND TESTING SHALL CONFORM TO THE APPLICABLE STANDARDS LISTED IN THE REFERENCED BUILDING CODE AND CONTRACT DOCUMENTS. 2.REPORT REQUIREMENT: APPROVED AGENCIES SHALL KEEP RECORDS OF SPECIAL INSPECTIONS AND TESTS. THE APPROVED AGENCY SHALL SUBMIT REPORTS OF SPECIAL INSPECTIONS AND TESTS TO THE AUTHORITY HAVING JURISDICTION AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. REPORTS SHALL INDICATE THAT WORK INSPECTED OR TESTED WAS OR WAS NOT COMPLETED IN CONFORMANCE TO APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF THEY ARE NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE AUTHORITY HAVING JURISDICTION AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE PRIOR TO THE COMPLETION OF THAT PHASE OF THE WORK. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND TESTS AND CORRECTION OF ANY DISCREPANCIES NOTED IN THE INSPECTIONS OR TESTS SHALL BE SUBMITTED AT A POINT IN TIME AGREED UPON PRIOR TO THE START OF WORK BY THE OWNER OR THE OWNER'S AUTHORIZED AGENT TO THE AUTHORITY HAVING JURISDICTION. CONTRACTOR RESPONSIBILITY 1.THE CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A MAIN WIND -FORCE RESISTING SYSTEM OR A MAIN SEISMIC-FORCE-RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM, OR A WIND-FORCE-RESISTING COMPONENT, OR SEISMIC-FORCE RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS OR CONTRACT DOCUMENTS SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE OWNER OR AUTHORITY HAVING JURISDICTION OR OWNER'S AUTHORIZED AGENT, AND ENGINEER OF RECORD PRIOR TO COMMENCEMENT OF THE WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL CONTAIN ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL INSPECTIONS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS (REFERENCE 1704.4 OF THE 2022 CALIFORNIA BUILDING CODE). 2.THE CONTRACTOR SHALL CORRECT DISCREPANCIES IDENTIFIED IN THE SPECIAL INSPECTIONS AND TESTS WHERE WORK WAS NOT COMPLETED IN CONFORMANCE TO APPROVED CONSTRUCTION DOCUMENTS. STATEMENT OF SPECIAL INSPECTIONS 1.THE SPECIAL INSPECTION AND TESTING NOTES AND TABLES WITHIN THESE CONTRACT DOCUMENTS WILL ACT AS A STATEMENT OF SPECIAL INSPECTIONS, UNLESS ADDITIONAL INFORMATION OR DOCUMENTATION IS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. STRUCTURAL OBSERVATIONS: STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION OF THE STRUCTURAL SYSTEM, STRUCTURAL ELEMENTS, AND THEIR CONNECTIONS FOR GENERAL CONFORMANCE TO THE CONTRACT DOCUMENTS AT SIGNIFICANT CONSTRUCTION STAGES AND AT THE COMPLETION OF THE STRUCTURAL SYSTEMS. STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR INSPECTIONS REQUIRED BY CHAPTER 17 OF THE 2022 CALIFORNIA BUILDING CODE OR THE CONTRACT DOCUMENTS. ALL STRUCTURAL OBSERVATIONS SHALL BE IN ACCORDANCE WITH CHAPTER 1704.6 OF THE 2022 CALIFORNIA BUILDING CODE. THE OWNER SHALL RETAIN A REGISTERED DESIGN PROFESSIONAL (LICENSED IN CALIFORNIA) OR THE ENGINEER OF RECORD TO PERFORM ALL THE STRUCTURAL OBSERVATIONS REQUIRED. THE CONTRACTOR OR CONSTRUCTION MANAGER SHALL NOTIFY THE ENGINEER OF RECORD AND PERSONS PERFORMING THE STRUCTURAL OBSERVATION AT LEAST (5) FIVE WORKING DAYS (FOR EACH OBSERVATION) PRIOR TO THE WORK THAT IS REQUIRED TO BE OBSERVED IS COVERED. DEFICIENCIES FOUND DURING THE STRUCTURAL OBSERVATIONS SHALL BE CORRECTED BY THE CONTRACTOR. AT A MINIMUM, STRUCTURAL OBSERVATIONS SHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE: STRUCTURAL OBSERVATION TABLE CONSTRUCTION SEQUENCE WHAT TO OBSERVE SUBGRADE AND SOIL PREPARATION STRUCTURAL FILL AND SUBGRADE VERIFY THE MATERIALS BELOW THE FOUNDATION HAVE BEEN INSTALLED IN CONFORMANCE WITH THE CONTRACT DOCUMENTS FOUNDATION REINFORCEMENT FOR BAR SIZES, SPACING, CLEARANCES, DEPTH OF REINFORCEMENT TO TOP OF FORMS, FORMWORK. OBSERVE PRIOR TO CONCRETE PLACEMENT PLACEMENT OF WALL DOWELS, LAPS, ANCHOR BOLTS, STEEL EMBEDS CONCRETE CONSTRUCTION REINFORCEMENT FOR BAR SIZES, SPACING, CLEARANCE, OBSERVE PRIOR TO CONCRETE PLACEMENT, LAPS, ANCHOR BOLTS, EMBEDS DEFERRED SUBMITTALS IN ACCORDANCE WITH THE 2022 CBC, SECTION 107.3.4.1 SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD WHO SHALL REVIEW THEM AND FORWARD THEM TO THE AUTHORITY HAVING JURISDICTION WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL OR AUTHORITY HAVING JURISDICTION. PRIOR TO ORDERING OR FABRICATION OF ANY MATERIALS, AND PRIOR TO THE INSTALLATION OF THE INDICATED STRUCTURAL ELEMENTS, EQUIPMENT DISTRIBUTIONS SYSTEM, OR COMPONENT AND IT'S ANCHORAGE. THE CONTRACTOR SHALL SUBMIT THE REQUIRED CALCULATIONS, SUPPORTING INFORMATION, AND DRAWINGS FOR REVIEW AND ACCEPTANCE BY THE ENGINEER. ALL DEFERRED SUBMITTALS AND CALCULATIONS SHALL BE IN ACCORDANCE WITH THE 2019 CALIFORNIA BUILDING CODE, INCLUDING THE DESIGN CRITERIA AND SPECIFICATIONS WITHIN THESE CONSTRUCTION DOCUMENTS. ALL DEFERRED SUBMITTAL CALCULATIONS AND DRAWINGS SHALL BE SEALED AND SIGNED BY A REGISTERED PROFESSIONAL CIVIL ENGINEER OR STRUCTURAL ENGINEER LICENSED IN THE STATE OF CALIFORNIA. THE FOLLOWING IS A LIST OF DEFERRED SUBMITTALS THAT ARE EXPECTED TO CONTAIN STRUCTURAL CALCULATIONS OR SAFETY RELATED SYSTEM INFORMATION FOR REVIEW TO MEET THE PROJECT REQUIREMENTS: DEFERRED SUBMITTAL ITEMS ANCHORAGE FOR GENERATOR AND FUEL TANK TO THE EXISTING FOUNDATION SYSTEM. POST-INSTALLED ANCHORS 1.POST-INSTALLED ANCHORS SHALL BE STAINLESS STEEL TYPE 304. POST-INSTALLED ANCHORS SHALL HAVE A CURRENT AND RELATIVE ICC-ES OR IAPMO-UES REPORT. POST-INSTALLED ANCHORS WITHOUT A CURRENT AND RELATIVE ICC-ES OR IAMPO-UES REPORT WILL NOT BE ACCEPTED. 2.NUTS SHALL BE ASTM F594, ALLOY GROUP 1 CW1 (F954C) OR CW2 (F594D). NUTS SHALL BE HEX OR HEAVY HEX HEAD AND SHALL MEET THE DIMENSIONAL REQUIREMENTS OF ASME B18.2.2 3.WASHERS SHALL BE STAINLESS STEEL TYPE 304 (AISI 304). WASHERS SHALL BE ROUND AND MEET THE DIMENSIONAL REQUIREMENTS OF ASME B18.21.1 4.SUBMIT ANCHOR INFORMATION, WASHERS, AND NUTS FOR SUBMITTAL REVIEW PRIOR TO ORDERING OR FABRICATING ANY MATERIALS. 5.LOCATE AND AVOID ALL REINFORCEMENT PRIOR TO DRILLING INTO THE CONCRETE. FOLLOW THE MANUFACTURER'S REQUIREMENTS AND ICC-ES OR IAPMO-UES REPORT FOR INSTALLATION INSTRUCTIONS. 6.CONCRETE SHALL HAVE A MINIMUM AGE OF 21-DAYS, SHALL NOT BE EXPOSED TO WATER FOR THE PRECEDING 14-DAYS, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI AT THE TIME OF ANCHOR INSTALLATION. DO NOT DRILL INTO CONCRETE PRIOR TO 21-DAYS. DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 NOTES: 1.THE LAP LENGTH TABLE IS SPECIFIC TO TENSION DEVELOPMENT AND TENSION LENGTHS FOR WALLS, SLABS, AND FOOTINGS IN CONCRETE IN ACCORDANCE WITH ACI 318-19, CHAPTER 25 AND THE CRITERIA IN THIS DETAIL. CONTACT THE ENGINEER OF RECORD FOR ANY DISCREPANCIES TO THE CRITERIA IN THIS DETAIL. 2.LAP SPLICE LENGTHS ARE CLASS B LAPS, IN INCHES, FOR GRADE 60 REINFORCEMENT IN NORMAL WEIGHT CONCRETE WITH f'c GREATER THAN OR EQUAL TO 3,000 PSI. 3.CENTER-TO-CENTER SPACING OF REINFORCING SHALL BE GREATER THAN TWICE THE CONCRETE COVER PLUS ONE BAR DIAMETER. 4.TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12 INCHES OF CONCRETE CAST BELOW BARS. 5.FOR BARS OF DIFFERENT SIZES, THE LAP SPLICE LENGTHS OF THE SMALLER BAR SHALL BE USED. 6.STAGGER LAPS A DISTANCE OF ONE-HALF THE SPLICE LENGTH, UNLESS OTHERWISE NOTED. LAP SPLICE LENGTH FOR REINFORCING BARS IN WALLS, SLABS & FTNGS (INCHES) IMPERIAL [SOFT METRIC] BAR SIZE COVER=1.00 IN.COVER=2.00 IN.COVER=1.50 IN. TOP4 OTHER TOP 4 OTHER TOP 4 OTHER #3 [#10]17 16 17 16 17 16 #4 [#13]23 17 23 17 23 17 222822282633#5 [#16] #6 [#19]46 35 34 26 34 26 384943555774#7 [#22] #8 [#25]93 72 70 54 56 43 5369668687113#9 [#29] #10 [#32]137 106 105 81 85 66 #11 [#36]162 125 125 97 102 79 SCALE: NTS REV 01 S-3010CONCRETE REBAR LAP SPLICE CONCRETE COMPRESSIVE STRENGTH, f'c ≥ 3,000 PSI HOOK A or G J d D 4d 2 1/2" MIN DETAILING DIMENSION DETAILING DIMENSION d D 12dA o r G 180° D = FINISHED INSIDE BEND DIAMETER (INCLUDES SPRINGBACK) d =BAR DIAMETER ACI 318-19 MIN BEND DIAMETER: 6d FOR #3 THROUGH #8 8d FOR #9, #10 & #11 10d FOR #14 AND #18 RECOMMENDED END HOOK DIMENSIONS BAR SIZE D 180 ° HOOKS 90° HOOKS A or G J A or G #3 0'-2 1/4"0'-5"0'-3"0'-6" #4 0'-3"0'-6"0'-4"0'-8" #5 0'-3 3/4"0'-7"0'-5"0'-10" #6 0'-4 1/2"0'-8"0'-6"1'-0" #7 0'-5 1/4"0'-10"0'-7"1'-2" #8 0'-6"0'-11"0'-8"1'-4" #9 0'-9 1/2"1'-3"0'-11 3/4"1'-7" #10 0'-10 3/4"1'-5"1-'1 1/4"1'-10" #11 1'-0"1'-7"1'-2 3/4"2'-0" 90° SCALE: NTS S-3020REINFORCING HOOKS REV 01 NOTES: 1.PREFORMED JOINT FILLER SHALL COMPLY WITH ASTM D1752, TYPE 1. 2.BOND BREAKER TAPE SHALL BE AN ADHESIVE BACKED GLAZED BUTYL OR POLYETHYLENE TAPE WHICH WILL SATISFACTORY ADHERE TO THE PREFORMED JOINT FILLER OR CONCRETE SURFACE. THE TAPE SHALL BE THE SAME WIDTH AS THE JOINT. 3.BACKING ROD: 1-1/4" Ø EXTRUDED, CLOSED CELL, POLYETHYLENE FOAM ROD. BACKING ROD SHALL BE COMPATIBLE WITH SEALANT. CONCRETE SLAB OR FOUNDATION PER PLAN (REINFORCEMENT NOT SHOWN FOR CLARITY) JOINT SEALANT: SIKAFLEX-1C SL OR APPROVED EQUAL BACKER ROD (NOTE 3) 1" THICK PREFORMED JOINT FILLER (NOTE 1) 12T INDICATES EDGE OF (E) SLAB / WALL OR NEW SLAB / WALL PER PLAN SCALE: NTS S-3161EXPANSION JOINT REV 01 SLAB AT WALL OR ADJACENT SLAB TO SLAB T (T H I C K N E S S ) E-5 1EQUIPMENT ANCHORAGE SCHEDULE NOTES: 1.THE EQUIPMENT LISTED IN THIS SCHEDULE HAVE BEEN DESIGNED FOR THE OPERATING WEIGHT AND CONSTRAINTS IDENTIFIED. CONTACT THE ENGINEER OF RECORD FOR ANY DISCREPANCIES DURING EQUIPMENT SUBMITTAL PROCUREMENT. CHANGES OR MODIFICATIONS TO THE ATTACHMENT POINTS OR EXISTING STRUCTURE MAY BE REQUIRED. 2.FOR EQUIPMENT NOT LISTED ABOVE, OR EQUIPMENT THAT IS LESS THAN 400 LBS FLOOR MOUNTED, EXCEPTIONS TO ANCHORAGE DESIGN MAY APPLY. SUBMIT ANY EQUIPMENT NOT LISTED FOR FAVORABLY REVIEW. 3.LOCATE AND AVOID ALL REINFORCEMENT PRIOR TO DRILLING INTO THE CONCRETE OR CMU. 4.ANCHORS SHALL BE STAINLESS STEEL TYPE 304 HILTI KWIK BOLT-TZ2 OR APPROVED EQUAL. FOLLOW ICC ESR-4266 FOR INSTALLATION INSTRUCTION AND RECOMMENDATIONS. ALTERNATE ANCHORS ARE SUBJECT TO A FAVORABLY REVIEW BY THE ENGINEER OF RECORD AND SHALL HAVE A CURRENT ICC-ESR OR IAPMO-UES REPORT. 5.BOTTOM ANCHORAGE LOCATIONS AT (E) CONCRETE PAD OR FOUNDATION. MINIMUM CONCRETE EDGE DISTANCE TO ANCHOR SHALL NOT BE LESS THAN 2.5-INCHES. ISOMETRIC OF EQUIPMENT TOP ANCHORAGE POINT AT (E) CONCRETE OR CMU WALL EQUIPMENT ANCHORAGE SCHEDULE EQUIPMENT TYPE EQUIPMENT DIMENSIONS (W x D x H) MAXIMUM OPERATING WEIGHT ANCHORAGE AT BOTTOM MINIMUM EDGE DISTANCE ANCHORAGE AT TOP AUTOMATIC TRANSFER SWITCH (ATS)24" L x 17" W x 63" TALL 400 LBS (4) 1/2" Ø X 3.75" EMBEDMENT SEE NOTE 5 (2) 1/2" Ø X 3.75" EMBEDMENT MANUAL TRANSFER SWITCH (MTS)38" L x 24" W x 73" TALL 650 LBS (4) 1/2" Ø X 3.75" EMBEDMENT 6 INCHES NOT APPLICABLE SCALE: NTS W = W I D T H L = LENGTH PLAN VIEW - ANCHORAGE LOCATIONS AT BOTTOM W = W I D T H 3" TALL CHANNEL CURB (IF APPLICABLE) 1" (TYP) S-3 2EXHAUST PIPE SUPPORT SCALE: NTS SECTION VIEW NOTES: 1.CONNECTIONS AT EXISTING DOUBLE 2X JOISTS SHALL BE WITH A 3/4" Ø DIAMETER STAINLESS STEEL (TYPE 304) THREADED BOLT W/ WASHERS AND NUTS AT EACH END (TYP). 2.ROD STIFFENERS SHALL BE INSTALLED WHERE THE THREADED ROD EXCEEDS 1'-0" IN LENGTH. 3.LOCATE PIPE SUPPORTS WITHIN 6-INCHES OF EACH 90° TURN, OR AT ENDS OF CONNECTIONS WITHIN 6-INCHES. THE MAXIMUM PIPE SUPPORT SPACING SHALL NOT EXCEED 4'-0" OC. 4.CAREFULLY REMOVE ALL EXISTING PIPE INSULATION AND RE-USE EXISTING PIPE INSULATION OR REPLACE TO MACH EXISTING. (E) DOUBLE 2X8 OR (E) BLOCKING AT PIPE SUPPORTS PER RECORD DRAWINGS, VERIFY IN FIELD (TYP) TOLCO FIG 980 SWIVEL SWAY BRACE (OR APPROVED EQUAL) AT EACH END (TYP) 8" Ø EXHAUST PIPING W/ INSULATION PER MECHANICAL DRAWINGS 6" MAX DISTANCE FROM TOP AND BOTTOM OF THREADED ROD TO STIFFENER (TYP) B-LINE B22 CHANNEL BRACE OR APPROVED EQUAL (MAX LENGTH NOT TO EXCEED 8'-0") SIDE VIEW 8" Ø EXHAUST PIPING W/ INSULATION PER MECHANICAL DRAWINGS B-LINE B22 CHANNEL BRACE OR APPROVED EQUAL (MAX LENGTH NOT TO EXCEED 8'-0") 34" Ø THREADED HANGER ROD B-LINE B22 STIFFENER W/ FIG 98 ROD STIFFENER HARDWARE (TYP) TOLCO FIG 980 SWIVEL SWAY BRACE (OR APPROVED EQUAL) AT EACH END (TYP) 3 4" Ø THREADED HANGER ROD B-LINE B22 STIFFENER W/ FIG 98 ROD STIFFENER HARDWARE (TYP) B-LINE B3100 CLEVIS HANGER W/ TOLCO FIG 1CBS CROSS BOLT SPACER, OR APPROVED EQUAL (TYP) (E) DOUBLE 2X8 OR (E) BLOCKING AT PIPE SUPPORTS PER RECORD DRAWINGS, VERIFY IN FIELD (TYP) LOCATE BOLT ABOVE NEUTRAL AXIS OF 2X (SEE NOTE 1) TOP CONNECTION FLAT WASHER OR B200 SERIES SQUARE WASHER W/ HEX NUT B-LINE 3060- 3 4 SIDE BEAM ANGLE CLIP OR 3"X3"X 12" BENT PLATE W/ PLATE WASHERS AND NUTS T&B (TYP) 1 1 1 1 1" (TYP) CONCRETE EQUIPMENT PAD SCHEDULE EQUIPMENT TYPE EQUIPMENT DIMENSIONS MAX OPERATING WEIGHT FOUNDATION TYPE LENGTH (L) WIDTH (W) THICKNESS (T)REINFORCEMENT MTS EQUIPMENT 38" L x 24" W X 73" TALL 650 LBS MAT 4'-2"3'-0"12"#5 @ 12" OC, EW, T&B SCALE: NTS REV 01 S-3342EQUIPMENT FOUNDATION SCHEDULE TYPICAL FOR EXTERIOR EQUIPMENT 1' - 0 " T 2" M I N , 4 " M A X , U O N 1'-0" LAP (TYP) EQUIPMENT OR ENCLOSURE AS SHOWN PER PLAN, SEE SCHEDULE FOR LIMITS OF FOUNDATION AND MAXIMUM NOT TO EXCEED VALUES (2) BARS AT THICKENED EDGE TO MATCH SLAB REINF. PLAN DIMENSION PER SCHEDULE (W x L) MAT FOUNDATION (PER SCHEDULE) SLAB w/ THICKENED EDGE (AS SHOWN ON PLAN) SECTION VIEW OPTIONAL CJ WHERE ADD'L RAISED PAD IS SHOWN ON PLAN. ROUGHEN TO A MINIMUM 1/4" AMPLITUDE RAISED EQUIP. PAD: NOT REQUIRED LAP (TYP) GRADE TO MATCH EXISTING ELEVATION AND TYPE, TYPICAL ALL AROUND NOTES: 1.THE FOUNDATIONS IDENTIFIED IN THIS SCHEDULE HAVE BEEN DESIGNED FOR THE OPERATING WEIGHT AND CONSTRAINTS IN THE TABLE. CONTACT THE ENGINEER OF RECORD FOR ANY DISCREPANCIES DURING THE EQUIPMENT SUBMITTALS. CHANGES OR MODIFICATIONS TO THE FOUNDATIONS MAY BE REQUIRED BASED EXCEEDING THE LIMITS IN THE SCHEDULE. UNLESS OTHERWISE SHOWN, ALL FOUNDATIONS SHALL BE MAT FOUNDATIONS. 2.EQUIPMENT BASE PLATE SHALL BE UNDERLAIN BY A MINIMUM 1/4" NON-SHRINK GROUT, 1/2" MAXIMUM NON-SHRINK GROUT. 3.REFERENCE DETAIL 1/S-2 FOR EQUIPMENT ANCHORAGE DESIGN FOR SPECIFIED EQUIPMENT IN THE SCHEDULE. 4.RAISED EQUIPMENT PAD MAY BE REQUIRED PER THE EQUIPMENT MANUFACTURER OR PER ELECTRICAL DRAWINGS. NOT REQUIRED FOR THE MTS EQUIPMENT, UNLESS REQUESTED BY THE CITY. 5.NEW EQUIPMENT PADS PLACED AGAINST EXISTING OR NEW WALLS OR FOUNDATIONS SHALL HAVE AN EXPANSION JOINT PLACED BETWEEN THE NEW CONCRETE EQUIPMENT PAD AND THE EXISTING OR NEW WALL OR FOUNDATION PER DETAIL S-3161 . S-3 3SILENCER SUPPORT DETAIL SCALE: NTS SECTION VIEW B3200- 3 4 WELDLESS EYE NUT BY B-LINE COOPER OR APPROVED EQUAL (E) DOUBLE 2X8 OR (E) BLOCKING AT PIPE SUPPORTS PER RECORD DRAWINGS, VERIFY IN FIELD (TYP) NOTES: 1.CONNECTIONS AT EXISTING DOUBLE 2X JOISTS SHALL BE WITH A 3/4" Ø DIAMETER STAINLESS STEEL (TYPE 304) THREADED BOLT W/ WASHERS AND NUTS AT EACH END (TYP). 2.ROD STIFFENERS SHALL BE INSTALLED WHERE THE THREADED ROD EXCEEDS 1'-0" IN LENGTH. 3.LOCATE SILENCER SUPPORTS AS SHOWN PER PLAN VIEW - BRACING SCHEMATIC. 4.CAREFULLY REMOVE ALL EXISTING PIPE INSULATION AND RE-USE EXISTING PIPE INSULATION OR REPLACE TO MACH EXISTING. 6" MAX DISTANCE FROM TOP AND BOTTOM OF THREADED ROD TO STIFFENER (TYP) (E) DOUBLE 2X8 OR (E) BLOCKING AT PIPE SUPPORTS PER RECORD DRAWINGS, VERIFY IN FIELD (TYP) THROUGH-BOLT PER NOTE 1 WITH FLAT WASHER OR B200 SERIES SQUARE WASHER W/ HEX NUT (TYP) B-LINE B22 STIFFENER W/ FIG 98 ROD STIFFENER HARDWARE (TYP) TRANSVERSE SUPPORT SHALL BE B-LINE B22 CHANNEL BRACE OR APPROVED EQUAL (MAX LENGTH NOT TO EXCEED 8'-0"). LONGITUDINAL SUPPORT SHALL BE SIMILAR TO THE TRANSVERSE SUPPORT, REFERENCE DETAIL 2/S-2 SIDE VIEW, SIMILAR FOR CONNECTION DETAIL SILENCER W/ INSULATION PER MECHANICAL DRAWINGS 1 1 B-LINE 3060- 3 4 SIDE BEAM ANGLE CLIP OR 3"X3"X 12" BENT PLATE W/ PLATE WASHERS AND NUTS T&B (TYP) TOLCO FIG 980 SWIVEL SWAY BRACE (OR APPROVED EQUAL) AT EACH END (TYP) B3144-24 STANDARD DOUBLE BOLT PIPE CLAMP THROUGH-BOLT PER NOTE 1 WITH FLAT WASHER OR B200 SERIES SQUARE WASHER W/ HEX NUT (TYP) 6" M A X PLAN VIEW - BRACING SCHEMATIC 6" ± 2"6" ± 2" SILENCER PER ELECTRICAL / MECHANICAL DRAWINGS NOT TO EXCEED 300 LBS TRANSVERSE BRACING (TYP OF 2), AWAY FROM WALL 30 ° M A X LONGITUDINAL BRACE SUPPORT AT EACH VERTICAL SUPPORT, ROTATE TO AVOID PIPE SUPPORTS IN SAME PLANE INDICATES VERTICAL SUPPORT (TYP OF 2) H = H E I G H T ANCHOR EDGE DISTANCE PER SCHEDULE (E) OR NEW CONCRETE PAD PER PLAN EQ EQ T 8-INCH THICK COMPACTED AGGREGATE BASE, SEE SOIL AND FOUNDATION NOTES ON SHEET S-1 COMPACTION OF NATIVE MATERIAL PER SOIL AND FOUNDATION NOTES ON SHEET S-1 #4 @ 9" OC DOWELS, EW REINF PER SCHEDULE W/ STD HOOKS 1 1 24 STRUCTURAL S-2 STANDARD DETAILS PIB PDS - POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023 (E) 24" THICK GENERATOR PAD W/ #6 @ 12" OC, T&B, EW 20'-8" (VIF) 3' - 4 " ( V I F ) 1' - 4 " (V I F ) 7' - 4 " ( V I F ) 3' - 4 " ( V I F ) 1'-3 1/2"10'-11" (VIF) (E) #5 DIAGONAL ADD BARS, 4 PLACES, TO REMAIN (TYP) 4' - 8 1 / 2 " ( V I F ) 4'-0" (VIF)4'-0" (VIF)4'-8" (VIF)4'-0" (VIF)4'-0" (VIF) 8" ( V I F ) 3' - 8 " ( V I F ) 6' - 0 " ( V I F ) 2' - 1 0 " ( V I F ) 1' - 8 " ( V I F ) 1' - 2 " 8" ( V I F ) 16 ' - 0 " ( V I F ) (V I F ) OP E N I N G AB O V E 6' - 1 " ( V I F ) 4' - 6 1 / 2 " ( V I F ) (E) 7" THICK FOUNDATION SLAB W/ #5@12" OC, EW (CENTERED) GENERATOR ROOM (EL 107.00) (E) 8" CMU WALL (TYP) (E) INSULATION, SEE NOTE 5 (TYP) OPENING ABOVE OPENING ABOVE 3'-0" (VIF) INDICATES (E) FOOTING BELOW (TYP) (VIF) GENERATOR AND FUEL TANK PER ELECTRICAL AND MECHANICAL DRAWINGS, SEE NOTES 6 & 7 PIPING ABOVE PER MECHANICAL DRAWINGS (SEE NOTE 8) SILENCER ABOVE PER MECHANICAL DRAWINGS (SEE NOTE 9) 25 STRUCTURAL S-3 GENERATOR ROOM FOUNDATION PLAN PIB PDS - POINSETTIA LIFT STATION GENERATOR REPLACEMENT IMPROVEMENT PLAN FOR: 25 3840-23 540-9 FINAL SUBMITTAL (FOR CONSTRUCTION) NOTES 1.ALL DIMENSIONS AND SIZES SHOWN ARE APPROXIMATE AND PROVIDED AS AN AID IN INTERPRETING THE ANTICIPATED EXISTING CONDITIONS. THE DIMENSIONS SHOWN ARE TO THE FACE OF EXISTING CMU WALL AND NOT TO THE FACE OF THE EXISTING INSULATION. "VIF" INDICATES "VERIFY IN FIELD". FIELD VERIFY ALL DIMENSIONS SHOWN WITH EXISTING CONDITIONS. 2.THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO ORDERING OR FABRICATING ANY MATERIALS. NOTIFY THE ENGINEER OF RECORD OF ANY POSSIBLE DISCREPANCIES BEFORE CONSTRUCTION. 3.DO NOT DAMAGE, OVERCUT, SCRATCH, OR CRACK ANY PORTION OF THE EXISTING STRUCTURE NOT INTENDED TO BE MODIFIED. PROTECT AND PRESERVE PORTIONS OF THE EXISTING STRUCTURE NOT INTENDED TO BE MODIFIED. 4.REFERENCE ELECTRICAL AND MECHANICAL DRAWINGS FOR THE SCOPE OF ITEMS TO BE REMOVED OR DEMOLISHED. EXISTING ANCHOR BOLTS SHALL BE CUT, BURNED BACK APPROXIMATELY 1-INCH, AND PATCHED WITH A NON-SHRINK, NON-METALLIC GROUT. 5.INDICATES EXISTING 2-INCH THICK SEMI-RIGID FIBERGLASS SOUND ABSORBING MATERIAL (INSULATION) OVER FINISHED WALLS AND CEILING. DAMAGED OR REMOVED INSULATION SHALL BE REPLACED BY THE SAME OR FAVORABLY REVIEWED EQUAL MATERIAL AND ATTACHMENT TO THE EXISTING STRUCTURE. SUBMIT PROCEDURE FOR REMOVAL AND RE-USE OR NEW INSULATION FOR REVIEW PRIOR TO ORDERING ANY MATERIALS. 6.THE NEW GENERATOR AND FUEL TANK SHALL SHALL BE LIMITED TO THE FOLLOWING: OVERALL DIMENSIONS (WITH FUEL TANK) = 9'-10" LONG X 3'-11" WIDE X 8'-9" TALL MAX OPERATING WEIGHT (INCLUDING FUEL TANK) = 14,260 LBS 7.THE ATTACHMENT OF THE GENERATOR TO THE FUEL TANK AND THE FUEL TANK SHALL BE DESIGNED, DETAILED, FABRICATED, AND INSTALLED BY THE CONTRACTOR AS A DEFERRED SUBMITTAL. REFERENCE DRAWING SHEET S-1 AND SPECIFICATION SECTION 01190 FOR ADDITIONAL INFORMATION. 8.REFERENCE DETAIL 2/S-2 FOR EXHAUST PIPE SUPPORT. 9.REFERENCE DETAIL 3/S-2 FOR SILENCER SUPPORT DETAIL AND PLAN VIEW BRACING PLAN SCHEMATIC. COORDINATE WITH ELECTRICAL AND MECHANICAL DRAWINGS FOR THE PLACEMENT OF THE SILENCER. 10.REFERENCE DETAIL S-3342 FOR MTS EQUIPMENT PAD FOUNDATION. COORDINATE LOCATION WITH CIVIL DRAWINGS. SCALE: NTS GENERATOR ROOM - FOUNDATION PLAN DocuSign Envelope ID: 22E0CD66-5F4E-491C-A1CF-7BC34D603F05 12/19/2023