HomeMy WebLinkAboutDWG 551-3; CT 2023-0005; JUNIPER COAST HOMES; 01-0412/17/2025 12/18/2025 SDRSD G-2*** SDRSD G-7*** SDRSD G-14A*** 4 H&A TC GENERAL NOTES 1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING IMPROVEMENTS SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE. RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF-WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCT/ON. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE MUST BE FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRENCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HAVE A RA TING OF "A-" OR BETTER AND A SIZE CA TE GORY OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RA TING GUIDE 5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER APPROPRIATE AGENCIES. 6. REVISION OF THESE PLANS MAY BE REQUIRED IF THE PROPOSED IMPROVEMENTS ARE NOT CONSTRUCTED PRIOR TO THE DEADLINE DATE OF THE IMPROVEMENT AGREEMENT. 7. NO REVISIONS WILL BE MADE TD THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATESHEETOFTHEPLANS AND TITLE SHEET. 8. ORJGINAL ORA WINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 9. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 10. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCT/ON. 11. WHERE TRENCHES ARE WITHIN C/TYEASEMENTS,ASO/LSREPORTCOMPRISEDOF: (A) SUMMARY SHEET, (BJ LABORATORY WORK SHEETS AND (CJ COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA. PR/NC/PALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF COMPLETION OF FIELD TESTS. THE WRITTEN FIELD COMPACTION REPORT(S) SHALL BE IMMEDIATELY SUBMITTED TO THE CITY ENGINEERING INSPECTOR UPON COMPLETION OF THE FIELD TESTS. 12. A PRECONSTRUCT/ON MEETING SHALL BE HELD PRIOR TO THE BEGINNING OF WORK AND SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION TESTING AND ALL OTHER ASPECTS OF THE WORK THE CONTRACTOR SHALL SCHEDULE THE MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 A TLEAST FIVE (5) WORKING DAYS PRIOR TO STARTING CONSTRUCT/ON. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. 13. ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCT/ON MEETING WILL BE MADE BY CAWNG THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT 1760/ 438-3891. INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE WORK DAY BEFORE THE INSPECTION IS NFFDEQ INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE REQUESTS MADE AFTER 2:00 PM. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 14. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEAL TH STANDARDS, LAWS AND REGULATIONS. 15. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPE OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUNDDUR/NG THE EXCAVATION OF SUCH TRENCHORTRENCHESORDUR/NGTHEPIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5) OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS TITLE 8 CALIFORNIA ADMINISTRATIVE CODE THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 16. NO BLASTING SHALL BE COMMENCED WITHOUT A CITY ENGINEER APPROVED BLASTING PROGRAM AND BLASTING PERMIT. 17. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK ZONE DURING CONSTRUCTION OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 18. ALL OPERA T/ONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCT/ON EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND 6:00 PM. EACH DAY, MONDAY THRU FRIDAY AND NO EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLi DAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERJNG DEPARTMENT COUNTER.) 19. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY INSPECTOR FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTE OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERA T/ON. 20.IMPORT MATERIAL SHALL BE OBTAINED FROM,ANDWASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESl'ONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 21. THE EXISTENCE AND LOCATION OF UTILITYSTRUCTURESANDFACILITIES SHOWN ON THE CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND ANY OTHER EXJSTING FACILITIES OR STRUCTURES NOT SHOWN. 22. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES(ABOVEGROUNDAND UNDERGROUND) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF THE CONSTRUCTION TO PERMIT THE REVISIONS OF THE CONSTRUCT/ON PLANS IF IT IS FOUND THAT THE ACTUAL LOCA T/ONS ARE IN CONFLICT WITH THE PROPOSED WORK. 23. THE CONTRACTOR SHALL NOTIFYAFFECTEDUTILITYCOMPANIES(SEEBELOW) AT LEASTTWOFULL WORKING DAYS PRIOR TO STARTING CONSTRUCT/ON NEAR THEIR FACILITIES AND SHALL COORDINATE WORK WITH A COMPANY REPRESENTATIVE UNDERGROUND SERVICE ALERT SDG&E AT&T TIME WARNER CABLE COX COMMUNICATIONS CITY OF CARLSBAD(STREETS AND STORM DRAIN) •CITY OF CARLSBAD(SEWER, WATER & RECLAIMED WATER) 'BUENA SAN/TA TION DISTRICT 'AS APPROPRIATE (800)422-4133 (800)411-7343 (800)892-0123 (760)438-7741 (619)262-1122 (760)434-2980 (760)438-2722 (760)726-1340 x1330 24./N ACCORDANCE THECITYSTORMWATERSTANDARDS ALL STORM DRAIN INLETS CONSTRUCTEDBY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTE DISCHARGE DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SATISFACTION OF THE CITY ENGINEER. J:\ACTIVE JOBS\4052 RINCON-270 JUNIPER\CIVIL\DRAWING\IMPROVEMENT PLANS\4052-CV-/P-01-TITLE.DWG STREET NOTES 1. ACTUAL STRUCTURAL SECTIONS WILL BE DETERMINED AFTER "R" VALUE TESTS HAVE BEEN CONDUCTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, ON THE PREPARED BASEMENT SOIL THE "R" VALUE TESTS AND THE ENGINEERED STRUCTURAL SECTION MUST BE SUBMITTED TO THE ENGINEERING INSPECTOR FOR REVIEW AND APPROVAL A MINIMUM OF TWO (2) CITY WORKING DAYS BEFORE THE WORK BEGINS. 2. STREET LIGHTS SHALL BE INSTALLED AS SHOWN ON THESE PLANS, UNDERGROUND CONDUIT RUNS, SERVICE POINTS AND HAND-HOLES SHALL BE SHOWN ON THE "AS-BUil T' PLANS. NO DIRECT BURIAL STREET LIGHT FOUNDATIONS WILL BE ALLOWED. ALL LUM/NA/RES SHALL BE ·cur OFF" TYPE 3. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF CURBS, CROSS GUTTERS OR SURFACING OF STREETS. 4. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 5. WHEELCHAIR RAMPS SHALL BE INSTALLED PER REQUIREMENTS OF TITLE 24, CALIFORNIA ADMINISTRATIVE CODE. 6. STREET TREES SHALL BE INSTALLED PER SECTION VI OF THE CITY OF CARLSBAD LANDSCAPE MANUAL 7. FIRE HYDRANT MARKERS SHALL BE PLACED IN THE STREET WITHIN THE LIMITS OF WORK OF THIS PLAN PER SDRS DWG M19. 8. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTURBED BY THIS WORK SHALL BE REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS ACT. 9. TWO (2) SETS OF SURVEY (CUT) SHEETS SHALL BE PROVIDED TO THE CITY ENGINEERING INSPECTOR. 10. STREET LIGHTS SHALL BE 4,000 LUMEN (25-32 WA TT) #ERLI-0-04-C5-30-A-GRA Y-L4 GE-EVOLVE-LED. SEWER NOTES 1. SEWER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CITY OF CARLSBAD ENGINEERING STANDARDS (LATEST EDITION), VOLUME 1-GENERAL DESIGN STANDARDS, CHAPTER 6-DESIGN CRITERIA FOR GRAVITY SEWER LINES AND APPURTENANCES, AND VOLUME 3 - STANDARD DRAWINGS AND NOTES AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, LA TEST EDITION (GREEN BOOK). 2. BEFORE ANY CONNECTION TO THE CITY'S EXISTING SYSTEM, A PERMIT SHALL BE OBTAINED FROM THE CITY. IT MUST BE SIGNED AND APPROVED BY THE CITY ENGINEER OR DESIGNEE. 3. BEFORE CONSTRUCTION BEGINS IN ANY PUBLIC RIGHT OF WAY, A CITY RIGHT OF WAY PERMIT SHALL BE REQUIRED. WATER NOTES 1. WATER & RECYCLED WATER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CITY OF CARLSBAD ENGINEERING STANDARDS" (LA TEST EDITION) VOLUMES 2 & 3. 2. BEFORE ANY CONNECTION OR SHUT DOWN OF VALVES ON EXISTING C.M. W.D. LINES, A PERMIT SHALL BE OBTAINEDFROMTHEC.M.W.D. OFFICE AND MUST BE SIGNED AND APPROVED BY THE CITY OF CARLSBAD'S DEPUTY CITY ENGINEER AND THE UTILITY OPERATIONS' PUBLIC WORKS MANAGER. 3. ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCT/ON MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 2:00 PM. ON THE WORK DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 4. NO TREES OR STRUCTURES SHALL BEALLOWEDINTHEWATERLINEEASEMENT,ALL EXISTING TREES AND STRUCTURES SHALL BE REMOVED PRJOR TO COMMENCEMENT OF WORK -ANY EXCEPTIONS SHALL REQUIRE WRITTEN PERMISSION FROM THE DISTRICT ENGINEER. 5. ALL BURIED COPPER PIPING AND APPURTENANCES SHALL BE PROTECTED BY MEANS OF CATHODIC PROTECTION. IF DEVELOPER/OWNER CONDUCTS A SOILS TEST REPORT AND DEMONSTRATES THAT PROTECTION CAN BE PERFORMED IN ANOTHER MANNER, THE DISTRICT ENGINEER WILL CONSIDER AN ALTERNATIVE FORM OF PROTECTION. 6. THE EXACT HORIZONTAL AND VERTICALALIGNMENTANDTYPEOFMATERIALSOFTHE FIRE LINE LOCATED BETWEEN THE DETECTOR CHECK VALVE AND BUILDING SHALL BE DETERMINED BY THE CITY OF CARLSBAD FIRE MARSHAL 7. ALL POTABLE WATER SERVICES SHALLBE1"AND ALL METERS SHALLBE1"(UNLESSOTHERWISE NOTED ON PLANS). 8. ALL WATER METER BOXES SHALL BE 17" X 30" X 12" POLYMER CONCRETE AS MANUFACTURED BY ARMORCAST OR EQUAL 9. MINIMUM SPACING BETWEEN POTABLE WATER SERVICESANDSEWERLATERALSSHALLBE10FEET. 10. THE TOP OF WATER METER BOXES SHALL BE FLUSH WITH THE FINISHED SURFACE GRADE. 11. CONSTRUCTION OF WATER MAINS AND RECYCLED WATER MAINS SHALL ADHERE TO THE "CRITERIA FOR THE SEPARATION OF WATER MAINS AND SANITARY SEWERS" PUBLISHED BY THE STATE OF CALIFORNIA'S DEPARTMENT OF HEALTH SERVICES. 12. AXIAL DEFLECTION AT THE PIPE JOINTS IS NOT ALLOWED. THE USE OF A HIGH-DEFLECTION COUPLING ATAPIPEJO/NTMAYBEPERMITTED BYTHE/NSPECTORONA CASE BY CASE BASIS NOT TO EXCEED 4 DEGREES TOTAL DEFLECTION PER COUPLING (2 DEGREES/EACH GASKET). USE CERTAINTEED "VINYL-IRON" H.D. FOR C900. 13. BEFORE CONSTRUCT/ON BEGINS IN ANY PUBLICR/GHTOFWAY,ACITYRIGHTOFWAYPERM/TSHALL BE REQUIRED. 14. NO CUTTING OR SNAPPING OF ASBESTOS CEMENT PIPE (ACP) IS PERMITTED. CONTRACTOR SHALL REMOVE ACP TO NEAREST COUPLING AND INSTALL ACP X PVC ADAPTORS AND THE NECESSARY PVC SIZE AND CLASS PIPE TO INSTALL THE TEE AT THE STATION 15. PRIOR TO BACKFILL, INSTALL TRACER WIRE ON TOP OF PIPE AND SECURE IN PLACE WITH 2-/NCH WIDE PLASTIC ADHESIVE TAPE AT MAXIMUM 10-FOOT INTERVALS. WIRE TO ENTER VALVE STANDS BY MEANS OF DRILLED HOLE IN PIPE STAND WALL JUST BELOW 4TTBOX WIRE IS NOT TO INTERFERE WITH VALVE NUT OPERATION. RUN TRACER WIRE CONTINUOUSLY ALONG PIPE AND TERMINATE IN ADJACENT VALVE BOXES FOR BURIED ASSEMBLIES OR BURIED VALVES. WHERE BURIED SPLICES OCCUR, USE AN ELECTRICAL EPOXY RESIN SUCH AS SCOTCHCAST, OR APPROVED EQUAL PROVIDE 24 INCHES OF COILED WIRE AT ACCESS POINTS FOR ATTACHMENTS OF PIPE LOCATING EQUIPMENT. EACH INSTALLED RUN OF PIPE SHALL BE CAPABLE OF BEING LOCATED USING THE TRACER WIRE. PROTECT WIRE INSULATION FROM DAMAGE DURING INSTALLATION AND BACKFILLING. WIRE INSULATION THAT IS BROKEN, CUT, OR DAMAGED SHALL BE REPLACED. TRACER WIRE SHALL BE AWG NO. 8 STRANDED COPPER WIRE WITH HIGH MOLECULAR WEIGHT POLYETHYLENE (HMW/PE) INSULATION SPECIF/CALLY DESIGNED FOR DIRECT BURIAL IN CORROSIVE SOIL OR WATER. POLYETHYLENE /NSULA T/ON SHALL CONFORM TO ASTM D 1248, TYPE 1, CLASS C. WIRES WITH CUT OR DAMAGED INSULATION ARE NOT ACCEPTABLE AND REPLACEMENT OF THE ENTIRE WIRE WHICH HAS BEEN DAMAGED WILL BE REQUIRED AT THE CONTRACTOR'S EXPENSE. 16. CONTRACTOR TO SUBMIT E-28 FORM TO CM&/, MINIMUM 2 WEEKS PRIOR TO SCHEDULED WATER SHUTDOWN. SIGNING AND STRIPING NOTES 1. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL SIGNING AND STRIPING. 2. SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LA TEST VERSION), CAL TRANS STANDARD SPECIF/CATIONS (JULY 2006 OR LA TEST VERSION THEREOF), THESE PLANS AND THE SPECIAL PROVISIONS. 3. ALL SIGNING AND STRIPING IS SUBJECT TO THE APPROVAL OF THE TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE, PRIOR TO INSTALLATION. 4. ANY DEVIATION FROM THESE SIGNING AND STRIPING PLANS SHALL BE APPROVED BY THE ENGINEER OF WORK AND PUBLIC WORKS DIRECTOR PRIOR TO ANY CHANGE IN THE FIELD. 5. ALL SIGNING AND STRIPING SHALL BE REFLECTIVE PER CAL TRANS SPECIF/CATIONS. STRIPING SHALL BE REPAINTED TWO WEEKS AFTER INITIAL PAINTING. SIGNING SHALL USE ENCAPSULATED LENS REFLECTIVE SHEETING (HIGH INTENSITY OR EQUAL). 6. PRIOR TO FINAL ACCEPTANCE OF STREET IMPROVEMENTS, ALL STREET STRJPING AND AND MARKINGS WITHIN A 500' PERIMETER OF THE CONSTRUCT/ON PROJECT WILL BE RESTORED TO A "LIKE NEW" CONDITION, IN A MANNER MEETING THE APPROVAL OF THE CITY INSPECTOR. 7. EXACT LOCATION OF STRIPING AND STOP LIMITLINESSHALLBEAPPROVEDBYTHETRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE PRIOR TO INSTALLATION. 8. CONTRACTOR SHALL REMOVE ALL CONFLICTING PAINTED LINES, MARKINGS AND PAVEMENTLEGENDS BY GRINDING. DEBRIS SHALL BE PROMPTLY REMOVED BY THE CONTRACTOR. 9. ALL PAVEMENT LEGENDS SHALL BE THE LA TEST VERSION OFTHE CAL TRANS METRIC STENCILS. 10. LIMIT LINES AND CROSSWALKS SHALL BE FIELD LOCATED. CROSSWALKS SHALL HAVE 10' INSIDE DIMENSION UNLESS OTHERWISE SPECIFIED. 11. ALL CROSSWALKS, LIMIT LINES, STOP BARS, PAVEMENT ARROWS AND PAVEMENT LEGENDS SHALL BE THERMOPLASTIC UNLESS OTHERWISE SPECIFIED. 12. FIRE HYDRANT PAVEMENT MARKERS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LA TEST VERSION) AND SAN DIEGO REGIONAL STANDARD DRAWING M-19. 13. ALL MEDIAN NOSES AND FLARES SHALL BE PAINTED YELLOW. 14. ALL SIGNS SHALL BE STANDARD SIZE AS SHOWN IN THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LA TEST VERSION) UNLESS OTHERWISE SPECIFIED. 15. SIGN POSTS SHALL BE SQUARE PERFORATED STEEL TUBING WITH BREAKAWAY BASE PER SAN DIEGO REGIONAL STANDARD DRAWING M-45. 16. WHEN A SIGN IS A TT ACHED TO A POLE, IT SHALL BE MOUNTED USING A STANDARD CITY OF CARLSBAD MOUNTING BRACKET WITH STRAPS. 17. EXISTING SIGNS REMOVED BY THE CONTRACTOR SHALL BE DELIVERED BY THE CONTRACTOR TO THE CITY OF CARLSBAD PUBLIC WORKS YARD AT 405 OAK AVENUE. 18. ALL SIGNS SHOWN ON THESE PLANS SHALL BE NEW SIGNS PROVIDED AND INSTALLED BY THE CONTRACTOR EXCEPT THOSE SIGNS SPECIFICALLY SHOWN AS EXJSTING TO BE RELOCATED OR TO REMAIN. 19. (IF NECESSARY) WHERE R4-7 SIGN AND OM1-3 OBJECT MARKER ARE TO BE INSTALLED IN A 2-FOOTWIDE MEDIAN NOSE, THE R4-7 SIGN SHALL BE 18"X24" AND THE OM1-3 OBJECT MARKER SHALL BE 12"X12" DECLARATION OF RESPONSIBLE CHARGE (SHEETS 1-4) I HEREBY DECLARE THAT/ AMTHEENGINEEROFWORKFOR THIS PROJECT, THAT /HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THATTHECHECKOFPROJECTDRAW/NGSAND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. DATE: ____ _ ~R~N,R.CE ofESS/or-i G L-41#, ~o. ~ R.C.E. NO:_~8=03=5~6 _____________ _ No. 80356 REG/STRA T/ON EXP/RAT/ON DA "~E·-~12~-3~1-=20=2=6 ______ _ FIRM: PASCO. LARET, SUITER, AND ASSOC/A TES, INC. !J9DRESS: 1911 SAND/EGO AVE, SUITE 100 C/V\\.. ~ CITY, STATE: SAN DIEGO, CA 92110 TELEPHONE: (858) 259-8212 OWNER'S SWPPP CERTIFICATE I (WE) ACKNOWLEDGE THAT I (WE) MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPs) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOB/LIZA TION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCT/ON RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCT/ON ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND SIGNED OFF BY THE CITY OF CARLSBAD. IF THIS PROJECT/DEVELOPMENT IS SUBJECT TOA STATE-REGULATED SWPPP, I (WE) ALSO AGREE A QUALIFIED SWPPP PRACTITIONER (QSP) HAS BEEN OR WILL BE RETAINED TO SUPERVISE IMPLEMENT AT/ON OF THE SWPPP IN ACCORDANCE WITH THE CALIFORNIA CONSTRUCT/ON ORDER AND MUNICIPAL PERMIT, LA TEST VERSION. KRIS C,tMPBELL FOR: DATE TOLL WEST COASTLLC SOURCE OF TOPOGRAPHY TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERA TED BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON: JULY 6, 2023 BY: PASCO, LARET, SUITER & ASSOCIATES TOPOGRAPHY SHOWN HEREON CONFORMS TO NA T/ONAL MAP ACCURACY STANDARDS PROJECT LOCATION THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S): 204-240-22 THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N 358 E 1665 (CCS 83) ADDRESS: 270 JUNIPER AVENUE, CARLSBAD, CA 92008 POST-CONSTRUCTION BMP TABLE STORMWA TER REQUIREMENTS THAT APPLY: EXEMPT FROM EXEMPT FROM CITY OF OCEANSIDE HIGHWAY '8 PACIFIC OCEAN NOT TO SCALE CITY OF VISTA CITY OF .K""-,..., SAN MARCOS CITY OF ENCINITAS VICINITY MAP PROJECT ADDRESS 270 JUNIPER AVENUE CARLSBAD, CA 92008 APN: 204-240-22 REFERENCE DRAWINGS CR 14995 PM 12335 MAP 12987 MAP 1747 PM 16289 MAP1803 CR 15001 PM 16596 MAP7961 PM7248 DWG 117-2 DWG 123-7 DWG 170-6 DWG 551-3A INDEX OF SHEETS 1 TITLE SHEET N.T.S. 2 JUNIPER AVENUE IMPROVEMENT PLAN 3-4 SECTIONS AND DETAILS LEGAL DESCRIPTION ABBREVIATION LEGEND EG = EXISTING GRADE FS = FINISHED SURFACE FG = FINISHED GRADE FL= FLOWLINE FF= FINISHED FLOOR GF = GARAGE FACE IE= INVERT ELEVATION LA = LANDSCAPE AREA TB = TOP OF BERM TC = TOP OF CURB TG = TOP OF GRATE ELEVATION TP = TOP OF PIPE RJ = RESTRAINED JOINT RIM= TOP OF RIM ELEVATION EXISTING GRADE FYSB = FRONT YARD SETBACK RYSB = REAR YARD SETBACK SYSB = SIDE YARD SETBACK LOT 2 OF BLOCK "Q" OF PALISADES NO.2, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 1803 FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, AUGUST 25, 1924. OWNER INFORMATION DEVELOPER WORK TO BE DONE THE IMPROVEMENT WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCT/ON, AS DIRECTED BY THE CITY ENGINEER. 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS 3. THIS SET OF PLANS 4. RESOLUTION NO 7533 DATED DECEMBER 18, 2024 5. THE STANDARD SPECIF/CA T/ONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK) 6. SOILS REPORT AND RECOMMENDATIONS BY LGC VALLEY, INC.: JOB. NO. 254003-01 DATED 10/26/2023, 06/07/2024, 04/04/2025, 08/06/2025, AND 12/04/2025 7. SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDITIONS DATED NIA 9. STORM WATER POLLUTION PREVENTION PLAN (TIER 2) PREPARED BY: PLSA . (SEE DWG 551-3A) 10. STORM WATER QUALITY MANAGEMENT PLAN PREPARED BY: PLSA DA TED: OCTOBER 2025 11. CALIFORNIA STORM WATER QUALITY ASSOCIATION BMP CONSTRUCT/ON HANDBOOK AND CAL TRANS CONSTRUCT/ON SITE BMP MANUAL LEGEND DESCRIPTION PROPERTY LINE RIGHT-OF-WAY ADJACENT LOT LINE CENTERLINE OF ROAD EXISTING CONTOUR PROPOSED CONTOUR EXISTING EDGE OF PAVEMENT EXISTING WATER MAIN (SIZE AND MATERIAL PER PLAN) EXISTING WATER SERVICE (TO BE ABANDONED) EXISTING SEWER MAIN (SIZE AND MATERIAL PER PLAN) EXITING GAS MAIN (SIZE PER PLAN) PROPOSED 6" PCC CURB AND GUTTER PROPOSED TYPE A 5" AC BERM PROPOSED 6" PVC SEWER LATERAL AND CLEANOUT PROPOSED 3" DOMESTIC WATER SERVICE WI 3" METER AND BACKFLOW PROPOSED 1" IRRIGATION SERVICE WI 1 • METER AND BACKFLOW PROPOSED 6" FIRE WATER SERVICE & BACKFLOW PROPOSED AC SAWCUT PROPOSED TYPE A4 STORM DRAIN CLEANOUT PROPOSED 12" RCP STORM DRAIN CAL TRANS VEHICULAR STOPPING SIGHT DISTANCE VIEW CORRJDOR STD. SDRSD G-5' CARLSBAD S-7 & S-8 CMWD W-7" &W-8 CMWD W-3" &W-8 CMWDW-9" SDRSDD-09 SYMBOL QUANTITY ----------- 140 140 Ill w w w-- w--~ 1 EA s s G G 125LF 22LF s s 0 1 EA w w I ◄ 1 EA w w ------0--0 1 EA w w -----,:;jjjjl 1 EA 150LF 6] 2EA 32LFPVT 45LFPUB -·--·-- NAME: KRIS CAMPBELL FOR: TOLL WEST COAST LLC A DELAWARE LIMITED LIABILITY NAME: KRIS Co\MPBELL FOR: TOLL WEST COAST LLC A DELA WARE LIMITED LIABILITY PROPOSED TRENCHING AND CARLSBAD RESURFACING WI AC PAVEMENT GS-26 & GS-28 J//////////////1 I~ •· -•-• • • ~---•· I 180LF COMPANY ADDRESS: 350 COMMERCE SUITE 200 /RV/NE, CA 92602 PHONE NO.: (714) 347-1375 COMPANY ADDRESS: 350 COMMERCE SUITE 200 /RV/NE, CA 92602 PHONE NO.: (714) 347-1375 BENCH MARK DESCRIPTION: 2.5 INCH DISK ---------------------LO CA Tl ON: IN THE SOUTHEAST CORNER OFA VAULT ADJACENT TO THE NORTHEAST CORNER OF THE NORTHBOUND COAST HIGHWAY 101 BRIDGE OVER THE AGUA HEDIONA LAGOON 0. 1 MILES SOUTH OF TAMARACK AVENUE, 38-FT EAST OF THE EDGE OF PAVEMENT RECORDED: 2002 PER ROS 17271 ELEVATION: 26.52' DA TUM: NGVD 29 ----------- BASIS OF BEARINGS THE CALIFORNIA COORDINATE SYSTEM OF 1983 (CCS-83), ZONE 6, EPOCH 1991.35, GRID BEARING N 66' 04' 32" E BETWEEN STATION "CLSB 141" AND STATION "CLSB 119" . . AS SAID STATIONS ARE PUBLISHED IN THE CITY OF CARLSBAD SURVEY CONTROL NETWORK PER RECORD OF SURVEY MAP NO. 17271, FILED IN THE OFFICE OF THE SAN DIEGO COUNTY RECORDER ON FEBRUARY 8, 2002. PROPOSED 4" PCC SIDEWALK/ PAVEMENT PROPOSED 2" AC GRIND AND OVERLAY PROPOSED MIN. 4" AC OVER 6" AB'"" PROPOSED 15-FT DIAMETER TREE CANOPY TREE WELL BMP PER DETAIL SHEET4 600SF 2,930SF 1,140 SF 1 EA PROPOSED TYPE B CURB INLET SDRSD D-02" 1 EA PROPOSED PCC DRIVEWAY APRON 255SF ALL STANDARD DRAWINGS ARE CITY OF CARLSBAD DRAWINGS (SDRSD) UNLESS NOTED OTHERWISE: ABBREV/A TION: SDRSD -SAN DIEGO REGIONAL STANDARD DRAWING CMWD -CARLSBAD MUNICIPAL WATER DISTRICT ""ACTUAL SECTION TO BE DETERMINED BY GEOTECH ENGINEER BASED ON R-VAULE TEST RESULTS PLSA 1r,-~ PLSAENGINEERING.COM I SH~T I • SAN DIEGO REGIONAL STANDARD DRAWING " CARLSBAD MUNICIPAL WATER DISTRICT STANDARD DRAWING ••• SDRSD AS MODIFIED BY CITY OF CARLSBAD "AS BUil T" P.E. EXP. DATE REVIEWED BY: INSPECTOR DATE I SHEETS I CITY OF CARLSBAD ENGINEERING DEPARlMENT IMPROVEMENT PLANS FOR: JUNIPER COAST HOMES 270 JUNIPER AVENUE PUD 2023-0007 IMP 2025-0001 TITLE SHEET CDP 2023-0058 APPROVED:TIMOTI-IY 0. CARROLL TRASH CAPTURE? HYDROMOD/F/CA T/ON? PRINCl'AL ENGINEER RCE 553111 EXP. 12/31 /26 DA1E tsj STANDARD STORMWATER REQUIREMENTS 11, PROJECT NO. DRAWING NO. tsj YES ~ YES DA1E INITIAL DA1E INITIAL DA1E INITIAL RVWD BY: PRIORITY PROJECT REQUIREMENTS NO NO REVISION DESCRIPTION CHKD BY: CT 2023-0005 551-3 ENGINEER Of WORK OlHER APPROVAL CllY APPROVAL PLSA4052 Docusign Envelope ID: EC7F77F8-CD7A-4270-8873-F956CDAC434F 4/30/2026 PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 "AS BUILT" DATE INSPECTOR DATE REVIEWED BY: IMP 2025-0001 551-3 JUNIPER COAST HOMES 270 JUNIPER AVENUE CT 2023-0005 PLSA 4052 4 GRAPHIC SCALE: 1" = 10' 0 10'20'30' J:\ACTIVE JOBS\4052 RINCON-270 JUNIPER\CIVIL\DRAWING\IMPROVEMENT PLANS SA V E D A T E : 20 2 6 - 3 - 2 5 - P L O T D A T E : 2 0 2 6 - 4 - 8 1 2 : 4 9 P M - F I L E N A M E : J : \ A C T I V E J O B S \ 4 0 5 2 R I N C O N - 2 7 0 J U N I P E R \ C I V I L \ D R A W I N G \ I M P R O V E M E N T P L A N S \ 4 0 5 2 - C V - I P - 0 2 - J N P R . d w g JUNIPER AVE CENTER LINE DATA TABLE #BEARING / DELTA LENGTH RADIUS 862.041 -N 55° 55' 48" E ALL EXISTING MONUMENTS TO BE PROTECTED IN PLACE. ANY MONUMENTS DESTROY DURING CONSTRUCTION SHALL BE REPLACED BY A LICENSED SURVEYOR AND PROPER DOCUMENTATION SHALL BE FILED WITH THE COUNTY RECORDER CURB & GUTTER DATA TABLE #BEARING / DELTA LENGTH RADIUS 2 1 REMARKS 121.48'N 55° 58' 45" E - 3.0'- 3 6" C&G SDRSD G-2 21.56'N 59° 30' 54" E -6" TYPE A AC BERM SDRSD G-5 PLAN VIEW - JUNIPER AVE IMPROVEMENTS SCALE: 1" = 10' 2 JUNIPER AVE. IMPROVEMENTS 1. UTILITIES ARE KNOWN TO EXIST IN THE AREA. INFORMATION SHOWN HEREON IS PER BEST AVAILABLE RECORD INFORMATION. EXACT HORIZONTAL AND VERTICAL LOCATION OF EXISTING UTILITIES UNKNOWN. CONTRACTOR TO VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO ORDERING MATERIALS AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD OF ANY DISCREPANCIES UPON DISCOVERY. 2. REMOVE EXISTING WATER SERVICE PER CITY OF CARLSBAD STANDARD SPECIFICATION 15000-3.12.A. REMOVE EXISTING SEWER LATERAL PER CITY OF CARLSBAD STANDARD 15000-3.12A. EXACT LOCATION OF EXISTING SEWER LATERAL SERVING PROJECT SITE UNKNOWN; CONTRACTOR TO VERIFY LOCATION IN THE FIELD DURING CONSTRUCTION 3. EXISTING GAS AND ELECTRICAL SERVICE TO BE REMOVED PER SEPARATE SDGE WORK ORDER. STREET STA. OF LAT @ MAIN IE @ MAIN LENGTH DROP TO MAIN LAT EL. @ PL (IE) LAT SLOPE GROUND EL. @ PL DEPTH BELOW PL (PL TO IE) UPSTREAM C/O RIM EL. BACKWATER VALVE REQ'D 4+30.16 44.9'46.3 IE0.70'34.8'51.8 NO5.0'2.0%51.3' SEWER LATERAL DATA TABLE - 6" PUBLIC SEWER LATERAL EXISTING SURVEY MONUMENT TO BE PROTECTED IN PLAN. MONUMENT SHALL BE REPLACED BY A LICENSED LAND SURVEYOR WHO SHALL FILE A CORNER RECORD WITH COUNTY IF DISTURBED OR DESTROYED. INSTALL 6" PVC SEWER LATERAL PER CITY OF CARLSBAD S-7 W/ CUT IN MODIFIED WYE CONNECTION PER S-10 TYPE C USING MAXADAPTER COUPLINGS PER MODIFIED S-10 DETAIL SHEET 3 2" AC GRIND AND OVERLAY SAWCUT EXISTING AC PAVEMENT SEE DETAIL SHEET 3 TRENCH AND RESURFACING W/ AC PAVEMENT PER CITY OF CARLSBAD GS-26, GS-28 INSTALL 1" IRRIGATION SERVICE METER AND BACK FLOW PER CMWD W-3 & W-6 CONSTRUCTION NOTES INSTALL 4" DOMESTIC WATER SERVICE, W/ 3" METER AND BACKFLOW PER CMWD W-7 & W-8; SEE NOTE THIS SHEET INSTALL 6" FIRE SERVICE AND WILKINS 475DA 6" RDPA OR APPROVED EQUAL PER CMWD W-9 CONSTRUCT PCC CURB AND GUTTER PER SDRSD G-2 SEE DATA TABLE THIS SHEET CONSTRUCT 6" TYPE A AC BERM PER SDRSD G-05 CONSTRUCT 24-FT WIDE PCC DRIVEWAY APRON PER SDRSD G-14A CONSTRUCT 4" PCC SIDEWALK PER SDRSD G-7 INSTALL TYPE B CURB INLET PER SDRSD D-02 L=5'; WITH STORMTEK ST3 TRASH CAPTURE DEVICE; TRASH CAPTURE TO BE MAINTAINED BY HOA INSTALL TYPE A4 STORM DRAIN CLEAN OUT PER SDRSD D-9 INSTALL TREE WELL BMP W/ 15-FT DIA. TREE CANOPY PER DETAIL SHEET 4 (PRIVATELY MAINTAINED) 150-FT STOPPING SIGHT DISTANCE CORRIDOR PER CALTRANS HIGHWAY DESIGN MANUAL MIN. 4" AC OVER 6" CLASS II AB PER GEOTECH RECOMMENDATION; STRUCTURAL SECTION TO BE VERIFIED DURING CONSTRUCTION BASED ON FIELD TESTED R-VAULE 1 2 3 4 5 7 8 9 10 11 12 15 16 STORM DRAIN DATA TABLE LINE LENGTH DELTA/BEARING RADIUS 16.85'N 39° 48' 56" W - SLOPE 1.1% REMARKS 44.73'1.0%PUB. 12" RCP; 2000 D-LOAD MIN.N 63° 54' 12" E - 12" PVT RCP; 1350 D-LOAD MIN 15.68'N 49° 40' 20" E -3.7% SITE NOTES WATER MAIN SHUTDOWN NOTE: EXCEPTED SHUTDOWN OF EXISTING 6" WATER MAIN FOR INSTALLATION OF WATER SERVICES. CONTRACTOR SHALL SUBMIT E-28 FORM TO CM&I 2 WEEKS PRIOR TO SCHEDULED SHUTDOWN. 17 ** ** **SEE SHEET 3 FOR SD PROFILES 1 2 3 12" PVT RCP; 2000 D-LOAD MIN 6 13 0" C&G TRANSITION TO 6" C&G EMRA NOTE ENCROACHMENT AGREEMENT PER DOC. 2025-0010 FOR PRIVATE STORM DRAIN PIPE 1 AC WATER MAIN REPLACEMENT NOTE: REMOVE AND REPLACE EXISTING 6" AC WATER MAIN TO NEAREST JOINT WITH 6" PVC WATER MAIN AT ALL NEW POINTS OF CONNECTION PER ENGINEERING STD VOL. 2-3.3.11.M.. RECONNECT EXISTING WATER SERVICE AFFECTED BY UPSIZING WITH SADDLE TAP CONNECTION PER CMWD W-13 N 55° 58' 45" E PROPOSED EASEMENT NOTE PROPOSED EASEMENT FOR WATER PURPOSES TO CARLSBAD MUNICIPAL WATER DISTRICT 1 14 4" WATER SERVICE NOTE: 4" WATER SERVICE BETWEEN REDUCER AT GATE VALVE NEAR TEE TO ABOVE GROUND 90-DEGREE ELBOW BEND AT METER; 3" AFTER BEND. **BEARING AREA BASED ON (AWWA C900 CLASS 305 PVC; 200 PSI MAX ASSUMED TEST PRESSURE PER W-19A W/ SAND AND GRAVEL BACKFILL 1,500 LB/SF); THRUST BLOCKS PER CMWD W-19 & W-19A MJ RESTRAINT NOTE: MECHANICAL JOINT RESTRAINT ON 4" DOMESTIC WATER SERVICE FROM CONNECTION AT MAIN TO 3" METER; MECHANICAL JOINT RESTRAINT ON 6" FIRE SERVICE FROM CONNECTION AT MAIN TO 6" BACKFLOW ***MIN. ANCHOR BLOCK VOLUME BASED ON WAS DESIGN GUIDELINES (AWWA C900 CLASS 305 PVC; 150 PSI TEST PRESSURE AND 140 LB/FT^3 BLOCK DENSITY); X X X X X X X X OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE C X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XX X X X XXXX X X X X X X X X X X X X X X X ELE : 5 5 . 8 7 I.E: 4 3 . 6 1 55 . 8 4 55 . 7 9 55 55 55 55 S55°58'45"W 122.48' X X X /// ////// /// /// /////////////// 54 ///////// X X X S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S SWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW W G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G S S S S S S S W W W W W W W W W W S SD SD SD SD S S W W W W W S S S S G G G G G W W W W W W W W W W W W G G G G G E WWWW W E E E EEE E IR R IR R IR R IR R W W W G G G G G G G G G E E E E E E E E E E E E E 3+00 4+00 5+00 6+00 JUNIPER AVENUE 10 . 0 ' 4. 0 ' 30 . 0 ' 20 . 0 ' 6. 0 ' LA ROW ROW LA CL CL3+00 4+00 5+00 6+00CLCL EXISTING GAS MAIN PER SDGE EX. 12" C.M.P STORM DRAIN @0.5% PER DWG. 123-7 ST A . 4 + 2 5 . 6 7 ~ 1 6 . 2 ' L T EX . G R A T E D S D I N L E T TO B E R E M O V E D (5 0 . 5 T G ) (4 7 . 5 I E ) 4 3 16 5 5 1 1 EX. 6" VC SEWER MAIN PER DWG. 117-2 EX. 6" AC WATER MAIN PER DWG. 170-6 EX. PUBLIC STREET LIGHT TO REMAIN ST A . 4 + 3 8 . 5 0 ~ 1 6 . 0 ' L T 51 . 6 5 R I M 47 . 5 I E I N N O R T H 47 . 5 I E I N W E S T (4 7 . 4 5 I E O U T E A S T ) 9 12 X'ING 4" DOM. SERVICE 50.5 IE 6" VC SEWER MAIN 45.0 TP X'ING 6" FIRE SERVICE 48.3 IE 6" VC SEWER MAIN 44.95 TP X'ING 1" IRR. SERVICE 46.5 TP 12" CMP SD 47.75 IE X'ING 4" DOM. SERVICE 49.45 IE 12" CMP SD 48.3 TP X'ING 6" FIRE SERVICE SERVICE 49.45 IE; 12" CMP SD 48.25 TP 3 LIMITS OF PROPOSED GRIND AND OVERLAY; C&G TO EDGE OF PAVEMENT (51.1 FS) X'ING 12" RCP SD 47.6 IE 6" PVC SEWER LAT 46.35 TP ST A . 4 + 9 1 . 1 0 ~ 1 6 . 0 ' L T 53 . 8 5 R I M 47 . 3 I E I N N O R T H (4 7 . 2 I E I N E A S T ) (4 7 . 1 5 I E O U T W E S T ) 1 PROJECT SITE APN: 204-240-22 SEE DWG 551-3A FOR ONSITE IMPROVEMENTS EX. SEWER C.O. (51.8 RIM) (~46.1 IE) EX. SEWER MH (55.84 RIM) (43.6 IE IN WEST) (43.5 IE OUT EAST) ST A . 4 + 3 0 . 1 6 ~ 4 . 8 ' R T CO N N E C T T O E X I S T I N G SE W E R M A I N ; 45 . 6 I E @ L A T ; (4 4 . 9 I E @ M A I N ) ST A . 4 + 8 4 . 4 2 ~ 1 3 . 8 ' R T CO N N E C T T O N E W 6 " P V C WA T E R M A I N S E E T B D A T A TA B L E T H I S S H E E T ; S E E PR O F I L E S H E E T 3 (~ 4 8 . 9 T P ) ST A . 4 + 7 7 . 2 8 ~ 1 3 . 6 ' R T CO N N E C T T O N E W 6 " P V C WA T E R M A I N S E E T B D A T A TA B L E T H I S S H E E T ; S E E PR O F I L E S H E E T 3 (~ 4 8 . 6 T P ) ST A . 4 + 1 1 . 6 7 ~ 1 1 . 2 ' R T CO N N E C T T O E X I S T I N G 6" A C W A T E R M A I N ; (~ 4 6 . 7 5 T P ) 1.1% 30 . 0 ' 60 . 0 ' EX. OVERHEAD UTILITIES TO BE REMOVED PER SEPARATE SDGE WORK ORDER ST A . 4 + 1 1 . 6 6 ~ 2 7 . 6 6 ' L T 1" I R R I G A T I O N W A T E R ME T E R ; ~ 4 7 . 5 T P ST A . 4 + 7 6 . 7 8 ~ 3 1 . 5 ' L T 3" D O M E S T I C W A T E R ME T E R ; ~ 4 9 . 9 T P ST A . 4 + 3 3 . 6 6 ~ 2 0 . 0 ' L T CL O F 2 4 - F T P C C DR I V E W A Y A P R O N ST A . 4 + 9 4 . 9 0 ~ 2 0 . 0 ' L T 54 . 2 8 T C ; 5 3 . 7 8 F L ST A . 5 + 0 3 . 6 7 ~ 2 0 . 5 ' L T MA T C H T O E X I S T I N G (5 4 . 7 T B ) ; ( 5 4 . 5 F L ) EXISTING COMMUNICATION PEDESTAL TO REMAIN ST A . 3 + 7 2 . 4 2 ~ 2 0 . 0 ' L T 50 . 7 1 T C ; 5 0 . 7 1 F L ; 0 " C & G ST A . 3 + 7 0 . 4 2 ~ 2 5 . 5 ' L T 50 . 8 F S 1 2 3 ST A . 4 + 6 7 . 1 5 ~ 2 6 . 3 ' R T EX . F I R E H Y D R A N T A N D SE R V I C E T O R E M A I N ST A . 3 + 7 7 . 9 1 ~ 1 0 . 0 ' L T EX . G A S S E R V I C E T O BE R E M O V E D P E R SE P A R A T E S D G E WO R K O R D E R ST A . 4 + 4 3 . 2 3 ~ 1 2 . 3 ' R T EX . W A T E R S E R V I C E AN D M E T E R T O B E RE M O V E D S E E S I T E NO T E 2 T H I S S H E E T EXISTING SEWER LATERAL TO REMAIN EX. AC SWALE TO BE REMOVED; AREA TO BE GRADE TO DIRECT DRAINAGE OVER NEW AC BERM OR EXISTING DRIVEWAY EX. AC DRIVEWAY TO REMAIN EX. AC BERM TO REMAIN EX. AC DRIVEWAY TO REMAIN EX. AC BERM TO REMAIN EX. POWER POLE TO REMAIN ST A . 4 + 5 6 . 5 6 ~ 2 2 . 5 ' L T 15 - F T M A R I N A S T R A W B E R R Y TR E E W E L L B M P P E R D W G 5 5 1 - 3 L EX. FENCE TO REMAIN EX. AC BERM TO REMAIN 16 10 10 91114 14 12 1599 13 2 6 7 8 5 EX. PCC DRIVEWAY APRON TO REMAIN 3 JUNIPER AVE STA. 4+33.66 = PVT DR STA. 1+00.00 ROW 51.3 FS (50.9 FS) 54.35 FS 2. 0 % MA X 2. 0 % MA X 2. 0 % MA X 9. 7 % LOT 1 MAP 7961 LOT 1 MAP 7248 PARCEL 1 PM 1443 BLOCK R LOT 2 SWLY 65.5' EXC SELY 105' MAP 1803 CL EX. PCC DRIVEWAY APRON TO REMAIN EXISTING DRY UTILITY VAULT TO REMAIN; ADJUST TO GRADE 4' X 4' WELD HOLE 17 1 3 2 ST A . 3 + 9 0 . 3 8 ~ 2 0 . 0 ' L T 51 . 0 5 T C 50 . 5 5 F L / L P 47 . 9 5 I E O U T E A S T 4.4% ST A . 4 + 2 5 . 6 7 ~ 1 6 . 2 ' L T CO N N E C T T O G A S MA I N P E R S E P A R A T E SD G E W O R K O R D E R 51.0 FS 51.65 FS 51.5 FS 51.6 FS 52.3 FS 52.15 FS 51.75 RIM 46.3 IE 53.0 FS 53 52 53.6 FS ST A . 3 + 7 3 . 4 2 ~ 2 0 . 0 ' L T 51 . 1 8 T C ; 5 0 . 6 8 F L Q100 = 5.25 CFS 1 1 REPLACE 6" AC WATER MAIN WITH 6" PVC WATER MAIN SEE NOTE THIS SHEET DEEP ROOT TREE BUBBLER PER SDRSD I-4 3.3% ROW 5 151.3 FS 2.0% PCC SIDEWALK WING TRANSITION PER SDRSD G-14 51 52 54 54 2. 8 % 2. 6 % 2. 6 % 1. 9 % 2. 0 % 2. 5 % 1. 9 % (51.47 FS) (51.92 FS) (52.18 FS) (51.55 FS) (0.5%) 51 LIMITS OF GRADING FOR DRAINAGE REPLACE AC BERM FROM EDGE OF ROW TO FACE OF SIDEWALK 53 (52.42 FS) LIMITS OF TRANSTION (52.49 FS) LIMITS OF TRANSTION EXISTING PCC CURB TO REMAIN (0.6%) EXISTING AC BERM TO REMAIN 51 5.5' LIMITS OF AC PAVEMENT TRANSITION ST A . 3 + 7 5 . 1 1 ~ 2 8 . 9 ' L T IN S T A L L S T R E E T T R E E P E R DW G 5 5 1 - 3 L ST A . 3 + 8 8 . 3 0 ~ 2 8 . 9 ' L T IN S T A L L S T R E E T T R E E P E R DW G 5 5 1 - 3 L ST A . 4 + 9 2 . 0 3 ~ 2 8 . 9 ' L T IN S T A L L S T R E E T T R E E P E R DW G 5 5 1 - 3 L STREET TREE MAINTENANCE NOTE: 1. THE HOA IS RESPONSIBLE FOR THE MAINTENANCE OF THESE TREES FOR ONE-YEAR FROM THE CITY'S ACCEPTANCE OF THE IMPROVEMENTS. 2. ONCE THIS PERIOD HAS BEEN COMPLETED AND THE TREES AVER VERIFIED TO BE IN GOOD HEALTH BY THE CITY'S PARKS MAINTENANCE REPRESENTATIVE, THE CITY WILL ASSUME MAINTENANCE. 3. ALL PUBLIC RIGHT-OF-WAY PLANTINGS, EXCEPT STREET TREES, WILL BE MAINTAINED BY THE HOA. PROFILE VIEW - JUNIPER AVE CL HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' (2.6%) (0.9%) 3+ 0 0 . 0 0 (5 1 . 5 8 F S ) 3+ 5 0 . 0 0 (5 1 . 3 0 F S ) 4+ 0 0 . 0 0 (5 1 . 6 1 F S ) 4+ 5 0 . 0 0 (5 2 . 5 3 F S ) 5+ 0 0 . 0 0 (5 4 . 4 5 F S ) 5+ 5 0 . 0 0 (5 5 . 6 2 F S ) 6+ 0 0 . 0 0 (5 5 . 1 9 F S ) 4+00 4+50 5+00 50 CL 54 CL 46 CL 58 CL 42 CL 3+503+002+90 5+50 6+00 50 CL 54 CL 46 CL 58 CL 42 CL (3.8%) (2.4%) (0.6%)(0.6%)4+ 2 5 . 0 0 (5 1 . 9 2 F S ) 3+ 7 0 . 4 2 (5 1 . 3 5 F S ) EXISTING 6" VC SEWER MAIN PER DWG 117-2 TOP OF EXISTING 6" AC WATER MAIN PER DWG 170-6 EXISTING GRADE AT STREET CENTERLINE ST A . 4 + 3 0 . 1 6 CO N N E C T T O E X I S T I N G SE W E R M A I N ; 45 . 6 I E @ L A T ; (4 4 . 9 I E @ M A I N ) ST A . 4 + 8 4 . 4 2 CO N N E C T T O N E W 6 " PV C W A T E R M A I N ; (~ 4 8 . 9 T P ) SE E P R O F I L E S H E E T 3 ST A . 4 + 7 7 . 2 8 CO N N E C T T O N E W 6 " PV C W A T E R M A I N ; (~ 4 8 . 6 T P ) SE E P R O F I L E S H E E T 3 ST A . 2 + 8 9 . 0 8 EX . S E W E R C O . (5 1 . 8 R I M ) ; (4 6 . 1 I E ) ST A . 5 + 8 3 . 4 0 EX . S E W E R M H (5 5 . 8 5 R I M ) ; (4 3 . 6 I E ) ST A . 4 + 1 1 . 6 7 CO N N E C T T O E X . 6 " A C WA T E R W A T E R M A I N ; (~ 4 6 . 7 5 T P ) 2 7 8 6 SOLID LINE REPRESENTS TOP OF CURB PROFILE VIEW - JUNIPER AVE TC LT HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' 50 TC 54 TC 50 TC 54 TC 4+00 4+50 5+003+70 (0.5%) EXISTING 12" CMP STORM DRAIN PER DWG 123-7 ST A . 4 + 2 5 . 6 5 ~ 1 6 . 2 3 ' L T EX . S T O R M D R A I N IN L E T T O B E R E M O V E D ST A . 4 + 3 8 . 5 0 ~ 1 6 . 0 ' L T 51 . 6 5 R I M ; 47 . 5 I E I N W E S T 47 . 5 I E I N N O R T H (4 7 . 4 5 I E O U T E A S T ) 14 1.0% 12" RCP STORM; SEE SD DATA TABLE THIS SHEET ST A . 4 + 9 1 . 1 0 ~ 1 6 . 0 ' L T 53 . 8 5 R I M ; 47 . 3 I E I N N O R T H (4 7 . 2 I E I N W E S T ) (4 7 . 1 5 I E O U T E A S T ) 14 ST A . 3 + 9 0 . 3 8 ~ 2 0 . 0 ' L T 51 . 5 5 T C / L P 47 . 9 5 I E O U T E A S T 13 3+ 9 0 . 3 8 51 . 0 5 T C / L P DASHED LINE REPRESENTS EXISTING FLOWLINE 4+ 5 0 . 0 0 52 . 3 2 T C DASH DOT LINE REPRESENTS PROPOSED FLOWLINE 4+ 0 0 . 0 0 51 . 1 0 T C PROPOSED 4" PVC DOM. WATER SERVICE 49.78 TP SEE PROFILE SHEET 3 PROPOSED 6" PVC DOM. WATER SERVICE 49.95 TP SEE PROFILE SHEET 3 PROPOSED 1" IRRIGATION WATER SERVICE 47.95 IE OUT 47.5 IE IN 4+ 7 5 . 0 0 53 . 4 0 T C (47.45 IE OUT) (47.15 IE OUT) (47.2 IE IN) 47.3 IE OUT (0.5%) 1.0' MIN. PVI STA: 3+95.00 PVI ELEV: 50.95 K: 9.81 LVC: 30.00 BV C S : 3 + 8 0 . 0 0 BV C E : 5 1 . 1 1 EV C S : 4 + 1 0 . 0 0 EV C E : 5 1 . 2 5 LOW PT. STA: 3+90.38 LOW PT ELEV: 51.05 PVI STA: 4+40.00 PVI ELEV: 51.85 K: 16.54 LVC: 40.00 BV C S : 4 + 2 0 . 0 0 BV C E : 5 1 . 4 5 EV C S : 4 + 6 0 . 0 0 EV C E : 5 2 . 7 3 4.4% 2.0%1.1% ST A . 3 + 7 3 . 4 2 51 . 1 8 T C ; 5 0 . 6 8 F L ST A . 4 + 9 4 . 9 0 54 . 2 8 T C ; 53 . 7 8 F L ST A . 3 + 7 0 . 4 2 50 . 7 1 T C ; 50 . 7 1 F L ST A . 4 + 3 3 . 6 6 ~ 2 0 . 0 ' L T CL O F P R O P O S E D 2 4 ' PC C D R I V E W A Y H&A TC • _- ' 0 0 ·O r ' ,-- . ' ' ' A-" p .A 0 0 0 0 0 0 □ - I + I t + -, ' l I ' I -' l I r -, I-, I I I ----i------- -, _l '-,-- l t ' T _I + ' ' I --,------_, - ' I --,....--, -, -----, -,- .-,------ 0 0 0 0 0 0 0 ' ' r-, -;-- ' T ' - ' - ,--- - ' ' "'-- ' j_ _/ _ _l__'-===t=--. ·- -,­" ' - r _j ' ' ' 0 0 0 T ' I ' ' .---r-,-- _L ,-- J ' ,--------,-' ' - - -, ' I ' ' '-----r 1\\.-==f=- C ' ' ,-- t t t t t --' -, -_j I ¢ ' I -J_ ! I T ~~_[~ 1-l~ • [ T~ ' _j _ I L ' t t _J -'' ,J / I _,_ ,-I ~l-1/"-/--z--==j ·,_ -• , ==;=== ,=_lr===~==·~-~'==-='~~~== ' - ,--,--J ' -, +-----,-r j l.. ' ' ' ' ' C ,--- I ' ' . I ' . --------,-_J \' ,---- I I ' I I ' I ' -------r-;---\ - -,---, T ' L !i'. \ I ...1 ,---- _t T _[ l ---l l ,--' --,, ' -' ' cl C ,--,-- ' ' -' _I .L I J L I - -, ,-- ' ' ' ----- ' ' ' ' ANCHOR BLOCK~: ~~M~ A!~;ME (CF! BEND I FITTI . SERVICE 36.5 4" DOMESTIC 90DEGBENO 900EGBENO 6' FIRE HYDRANT I 78.5 _l -, I ' J I . . 1 OCK DATA TABLE THRUST BL REA (SF) APPROX SIZE BEND/ FITTING ~BEARING A 2' X2' SERVICE 4" DOMESTIC 6 .. FIRE HYDRANT I r--' 90 DEG BENO 4,0 3· X 2.75' 90 DEG BENO 8.25 ' ' -, ' r- . ,-- - ' ' l I -, ,-, ' ' -, ' - ' I I ' ' --------;-----,-I 1--T ' ----,--I ,---I I ' ' --- L ' ' r- _j L -- -' ' - --I----l ' ' I -' ' ' ' ' I ) I l A=1--::,...._ ---:-r :::-:n.,,------,., • V □ F"" L.Ll I DAlE INITIAL : ENGINEER OF WORK REVISION DESCRIPTION -, . . . ' ' ..--r-- - ,-------, ' ' ,- - I I 1 --+-------r-,-----T, -,--' - - C / f_ J / r­r P L S~ ~l)ffMN •1 P.E.--EXP. PLSAENGINEERING.COM Y OF CARLSBAD I SHEET I CI~NGINEERING DEPARlMENT IMPROVEMENT PLANS FOR: I - ' I SHEETS I PUD 2023-0007 CDP 2023-0058 APPR0VED:TIM0THY 0. CARROLL DAlE INITIAL DlHER APPROVAL DA 1E INITIAL a1Y APPROVAL PRINCl'AL ENGINEER RVWD BY:--,' I CHKD BY: - RCE 553111 EXP .12/31/26 DAlE PROJECT NO. I DRAWING NO. - Docusign Envelope ID: EC7F77F8-CD7A-4270-8873-F956CDAC434F 4/30/2026 J:\ACTIVE JOBS\4052 RINCON-270 JUNIPER\CIVIL\DRAWING\IMPROVEMENT PLANS SA V E D A T E : 20 2 6 - 4 - 8 - P L O T D A T E : 2 0 2 6 - 4 - 8 9 : 0 2 A M - F I L E N A M E : J : \ A C T I V E J O B S \ 4 0 5 2 R I N C O N - 2 7 0 J U N I P E R \ C I V I L \ D R A W I N G \ I M P R O V E M E N T P L A N S \ 4 0 5 2 - C V - I P - 0 3 - S E C T S . d w g PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 "AS BUILT" DATE INSPECTOR DATE REVIEWED BY: IMP 2025-0001 551-3 JUNIPER COAST HOMES 270 JUNIPER AVENUE CT 2023-0005 PLSA 4052 43 SECTIONS & DETAILS TYPICAL DETAIL - AC PAVEMENT SAWCUT NOT TO SCALE TYPICAL SECTION - JUNIPER AVENUE NOT TO SCALE JUNIPER AVE STA. 3+80 NOT TO SCALE JUNIPER AVE STA. 3+90.77 NOT TO SCALE JUNIPER AVE STA. 4+80 NOT TO SCALE JUNIPER AVE STA. 4+30 NOT TO SCALE 4" WATER SERVICE NOTE: 4" WATER SERVICE BETWEEN REDUCER AT GATE VALVE NEAR TEE TO ABOVE GROUND 90-DEGREE ELBOW BEND AT METER; 3" AFTER BEND. MJ RESTRAINT NOTE: MECHANICAL JOINT RESTRAINT ON 4" DOMESTIC WATER SERVICE FROM CONNECTION AT MAIN TO 3" METER; MECHANICAL JOINT RESTRAINT ON 6" FIRE SERVICE FROM CONNECTION AT MAIN TO 6" BACKFLOW GU T T E R L I N E SA W C U T L I N E **18.5' MIN. 8.0' 6" PCC CURB & GUTTER PER SDRSD G-2 *STRUCTURAL SECTION MIN. 4" AC OVER 6" CLASS II AB OVER NATIVE SUBGRADE COMPACTED TO 95% REL. COMP. COLD PLANE AND OVERLAY (2" MIN. DEPTH) TO PROVIDE SMOOTH TRANSITION EXISTING AC PAVEMENT *TO BE VERIFIED BY PROJECT GEOTECH ENGINEER BASED ON FIELD TESTED R-VAULE **18.5' MIN. COLD PLANE AND OVERLAY AC PAVEMENT TO CENTERLINE; PROVIDED SMOOTH TRANSITION FROM SAWCUT SEE PLAN FOR ACTUAL DIMENSIONS 6" PROP. 4" PCC SIDEWALK PER SDRSD G-7 PROP. 6" PCC CURB AND GUTTER PER SDRSD G-2 SOUTH ROW PROPOSED AC PAVEMENT SAWCUT PER DETAIL THIS SHEET CLPL 10.0' 4.0' 0.5' 10.0' 4.5'5.5' 20.0'20.0' EX. 6" VC SEWER MAIN PER DWG 117-2 EX. 6" AC WATER MAIN PER DWG 170-6 EX. 12" CMP STORM DRAIN PER DWG 123-7 60.0' 1.5%(1-2%) EX. 6" PCC CURB AND GUTTER EX. 4" PCC SIDEWALK NORTH ROW 5.5' *4" AC OVER 6" CLASS II AB *TO BE VERIFIED BY PROJECT GEOTECH ENGINEER BASED ON FIELD TESTED R-VAULE 9.5'10.5' PROFILE VIEW - PVT STORM DRAIN LINE 3 HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' 1.2% 1+00 1+40 47 EL 51 EL 55 EL 47 EL 51 EL 55 EL PL / ROW PUBLIC PVT14 PROPOSED FINISHED SURFACE 12" RCP STORM DRAIN SEE SD DATA TABLE SHEET 2 18" X 18" BROOKS BOX PER DWG 550-3A JU N I P E R A V E ST A . 4 + 3 8 . 5 0 ~ 1 6 . 0 ' L T 51 . 6 5 R I M ; 47 . 5 I E I N W E S T 47 . 5 I E I N N O R T H (4 7 . 4 5 I E O U T E A S T ) 47.45 IE OUT 47.5 IE IN 47.7 IE OUT Q100=0.08 CFS V=1.67 FPS PL / ROW 1+00 1+40 PROFILE VIEW - PVT STORM DRAIN LINE 2 HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' 3.2% 47 EL 51 EL 55 EL 47 EL 51 EL 55 EL PUBLIC PVT 14 12" X 12" BROOKS BOX PER DWG 550-3A BMP PLANTER PER DWG 550-3A 18" X 18" BROOKS BOX PER DWG 550-3A 12" RCP STORM DRAIN SEE SD DATA TABLE SHEET 2 12" PVC STORM DRAIN PER DWG 550-3A 1.1%(47.15 IE OUT) 47.3 IE IN 47.8 IE OUT 47.9 IE IN ST A . 4 + 9 1 . 1 0 ~ 1 6 . 0 ' L T 53 . 8 5 R I M ; 47 . 3 I E I N N O R T H (4 7 . 2 I E I N W E S T ) (4 7 . 1 5 I E O U T E A S T ) PROPOSED FINISHED SURFACE Q100=0.06 CFS V=1.64 FPS CL LIMITS OF COLD PLANE TRANSITION (51.50 FS/EOP) 51.10 TC 50.60 FL PL / ROW 30.0' 10.5'9.5'10.0' 2.5% 2.0% MAX. AC PAVEMENT SAWCUT PER DETAIL THIS SHEET DASHED LINE REPRESENTS APPROX. EXISTING GRADE (50.6 FL/EOP) 12.4' GRIND AND OVERLAY 2.5% CL 30.0' 10.5'9.5'10.0' PL / ROW AC PAVEMENT SAWCUT PER DETAIL THIS SHEET 51.03 TC 50.53 FL/LP 2.0% MAX. (50.45 FL/EOP) LIMITS OF COLD PLANE TRANSITION (51.47 FS/EOP) 2.6% DASHED LINE REPRESENTS APPROX. EXISTING GRADE GRIND AND OVERLAY 12.3' PROPOSED D-2 CURB INLET 2.6% CL LIMIT OF COLD PLANE TRANSITION (53.62 FS) 53.62 TC 53.12 FL 30.0' 10.5'9.5'10.0' 2.0% MAX.2.7% AC PAVEMENT SAWCUT PER DETAIL THIS SHEET DASHED LINE REPRESENTS APPROX. EXISTING GRADE PL / ROW (53.0 FL/EOP) CL 51.67 TC 51.17 FL 30.0' 10.5'9.5'10.0' 2.0% MAX.9.7%2.1% AC PAVEMENT SAWCUT PER DETAIL THIS SHEET DASHED LINE REPRESENTS APPROX. EXISTING GRADE PL / ROW (50.6 FL)GRIND AND OVERLAY 19.5' LIMITS OF COLD PLANE TRANSITION (52.08 FS/EOP) EXISTING C&G 2.1% 47 EL 51 EL 55 EL 47 EL 51 EL 55 EL PROFILE VIEW - FIRE SERVICE CROSSING HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' CL 1+00 1+50 PL 8 EXISTING 12" CMP SD PER DWG 123-7; (47.23 IE) PROPOSED 6" PVC FIRE SERVICE ST A . 1 + 0 5 . 6 9 IN S T A L L 1 1 . 2 5 ° E L B O W ; 48 . 9 T P M J R E S T R A I N T S E E NO T E T H I S S H E E T ST A . 1 + 1 2 . 7 7 IN S T A L L 1 1 . 2 5 ° E L B O W ; 50 . 3 T P M J R E S T R A I N T S E E NO T E T H I S S H E E T EXISTING 6" VC SEWER MAIN PER DWG 117-2; (44.45 IE) DASHED LINE REPRESENTS APPROX. EXISTING GRADE SOLID LINE REPRESENTS APPROX. PROPOSE GRADE ST A . 1 + 0 0 . 0 0 CO N N E C T T O W A T E R M A I N SE E N O T E A C W A T E R M A I N RE P L A C E M E N T N O T E SH E E T 2 ; ( ~ 4 8 . 9 T P ) ST A . 1 + 2 2 . 7 7 IN S T A L L H I G H D E F L E C T I O N CO U P L I N G ; 5 0 . 3 T P M J RE S T R A I N T S E E N O T E T H I S SH E E T ST A . 1 + 3 2 . 7 7 IN S T A L L H I G H D E F L E C T I O N CO U P L I N G ; 4 9 . 9 5 T P M J RE S T R A I N T S E E N O T E T H I S SH E E T 3.0' (MIN.) EX. GAS MAIN; DEPTH TO BE VERIFIED IN THE FIELD CL 47 EL 51 EL 55 EL 47 EL 51 EL 55 EL PROFILE VIEW - 4" DOMESTIC WATER CROSSING HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' 1+00 1+50 PL 7 ST A . 1 + 0 0 . 0 0 CO N N E C T T O W A T E R M A I N SE E N O T E A C W A T E R M A I N RE P L A C E M E N T N O T E SH E E T 2 ; ( ~ 4 8 . 8 T P ) ST A . 1 + 0 5 . 2 3 IN S T A L L 1 1 . 2 5 ° E L B O W ; 48 . 7 2 T P M J R E S T R A I N T S E E NO T E T H I S S H E E T ST A . 1 + 2 2 . 9 3 IN S T A L L H I G H D E F L E C T I O N CO U P L I N G ; 4 9 . 7 8 T P M J RE S T R A I N T S E E N O T E T H I S SH E E T EXISTING 12" CMP SD PER DWG 123-7; (47.25 IE)EXISTING 6" VC SEWER MAIN PER DWG 117-2; (44.50 IE) PROPOSED 4" PVC DOMESTIC WATER SERVICE; SEE NOTE THIS SHEET SOLID LINE REPRESENTS APPROX. PROPOSE GRADE DASHED LINE REPRESENTS APPROX. EXISTING GRADE EX. GAS MAIN; DEPTH TO BE VERIFIED IN THE FIELD ST A . 1 + 1 2 . 5 5 IN S T A L L 1 1 . 2 5 ° E L B O W ; 50 . 1 7 T P M J R E S T R A I N T S E E NO T E T H I S S H E E T ST A . 1 + 2 2 . 5 5 IN S T A L L H I G H D E F L E C T I O N CO U P L I N G ; 5 0 . 1 7 T P M J RE S T R A I N T S E E N O T E T H I S S H E E T 3.0' (MIN.) H&A TC () "' ~ t I / > -I II I \ -- --\ \ ,... -/-1-~ u -- \ ■f----+----+----+----+----+--++----+----+--I ' / ,v - -V \ ' I\ -4----:: 'V , I I I I I I I I I I ------ ~ ' -!-_ . ...__ - I I I I~ -' ' ' " I \ I \ I \ "'I! I ' ' ' ' ' I I I ·-- I =-- I I I I I I _/I I I I I J 'I 1 -I I I I\. I ' ~ lJ I . . ' ' NOTES: GRIPPER GASKET LLC MAXADAPTER COUPLING GRIPPER GASKET LLC MAXADAPTER COUPLING I 3' PVC SEWER ,....._ __ _._,I PIPE SPOOL I )~ 45· PVC v wYc I I I f-----~ Ii i _/ ~l I 3' PVC SEWER PIPE SPOOL EXISTING PVC OR VCP SEWER MAIN 00_5 -n<1' MAXI'"'" PLAN FROM VERTICAL '\r------i 45• PV< 1~ WYE~1 ," / 45' ,,. I ~-~ ~ _.,, EXISTING PVC ---OR VCP SEWER MAIN ELEVATION TYPE C CUT-IN WYE CONNECTION FOR EXISTING VCP OR PVC PIPE 1. REFER TO SECTION 15063 FOR SEWER PIPE AND FITTINGS. 2. CONNECTION TO BE MADE 22.5-DEG MAX. FROM VERTICAL TO 45-DEG (AS SHOWN) FROM HORIZONTAL 3. NO MORE THAN ONE CUT IN WYE WILL BE ALLOWED FOR EACH LENGTH OF EXISTING VCP SEWER MAIN. 4. FOR SEWER LATERAL INSTALLATION SEE S-7 AND S-8. 5. FOR TRENCH BACKFILL SEE S-5. 6. MATERIALS SHALL BE SELECTED FROM THE APPROVED MATERIALS LIST. 7. 6-IN ON 6-IN ALLOWED FOR 270 JUNIPER AVENUE MODIFIED STD DWG S-10 AS APPROVED BY UTILITIES DEPARTMENT FOR 270 JUNIPER AVENUE 6-INCH SEWER CONNECTION. MARKUS MOHRLE, UTILITIES, SR. ENGINEER REV. APPROVED DATE CITY OF CARLSBAD 4" AND 6" SEWER SADDLE WYE CONNECTION CITY ENGINEER MODIFIED DWG. NO. 3/19/26 !5;'38;1@1 DATE S-10 -- -\ - \ -\ I I -=-~ _j ... ;--\ \ / --I PLSA ,l)ff~ PLSAENGINEERING.COM \ -- \ P.E. __ _ EXP----- ---------------+---+----+---+----I I SHEET I CITY OF CARLSBAD I SHEETS I ENGINEERING DEPARlMENT :==::...::::=========::....:::::=:::::: DAlE INITIAL ENGINEER OF WORK REVISION DESCRIPTION IMPROVEMENT PLANS FOR: PRINCl'AL ENGINEER PUD 2023-0007 CDP 2023-0058 APPR0VED:TIM0THY 0. CARROLL RCE 553111 EXP .12/31/26 DAlE DAlE INITIAL DAlE INITIAL RVWD BY: ---1 I PROJECT NO. I DRAWING NO. DlHER APPROVAL aTY APPROVAL CHKD BY: . . Docusign Envelope ID: EC7F77F8-CD7A-4270-8873-F956CDAC434F 4/30/2026 J:\ACTIVE JOBS\4052 RINCON-270 JUNIPER\CIVIL\DRAWING\IMPROVEMENT PLANS SA V E D A T E : 2 0 2 6 - 4 - 8 - P L O T D A T E : 2 0 2 6 - 4 - 8 9 : 0 2 A M - F I L E N A M E : J : \ A C T I V E J O B S \ 4 0 5 2 R I N C O N - 2 7 0 J U N I P E R \ C I V I L \ D R A W I N G \ I M P R O V E M E N T P L A N S \ 4 0 5 2 - C V - I P - 0 3 - S E C T S . d w g PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 "AS BUILT" DATE INSPECTOR DATE REVIEWED BY: IMP 2025-0001 551-3 JUNIPER COAST HOMES 270 JUNIPER AVENUE CT 2023-0005 PLSA 4052 44 SECTIONS & DETAILS SECTION C-C CURB CUT @ TREE WELL SDC GS DS GS 5.01 NOT TO SCALE PLAN VIEW - CURB CUT @ TREE WELL SDC GS DS GS-5.01 NOT TO SCALE PLAN VIEW - CURB CUT @ TREE WELL NOT TO SCALE SECTION D-D CURB CUT @ TREE WELL SDC GS DS GS 5.01 NOT TO SCALE NOT TO SCALE SECTION B-B TREE WELL W/ GRATE MODIFIED SDC GS 1.02 NOT TO SCALE SECTION A-A TREE WELL W/ GRATE MODIFIED SDC GS 1.02 TREE WELL NOTE: TREE WELL BMP TO BE PRIVATELY MAINTAINED BY HOA NOT TO SCALE SECTION E-E TREE WELL MODIFIED SDC GS 1.02 9" x 30" x 12" DEEP TYPE 1 SPLASH PAD PER SDC DS GS-5.06 (NO. 2 COARSE AGGREGATE ROCK) R=6" (TYP.) 6" PCC C&G PER SDRSD G-02GUTTER LIP 2 . 5 ' 1 . 0 ' 1 . 0 ' D D C C 18" CURB CUT OPENING CENTERED AT TREE WELL LOCATION AS SHOWN ON SHEET 4 GUTTER LIP 4 . 5 ' G U T T E R D E P R E S S I O N 6" PCC C&G PER SDRSD G-02 LIMITS OF 9" X 30" TREE GRATE SUPPORT TOP OF 6" PCC C&G TOP OF 6" PCC C&G 4.5' FLOWLINE (PER PLAN) FLOWLINE (PER PLAN)1" GUTTER DEPRESSION @ TREE WELL1" VERTICAL GUTTER TRANSITION OVER 1' HORIZONTAL 1.5' CURB CUT OPENING 1.0' 1.0' 7" 1" 2.5' 6" PCC CURB & GUTTER A A B B 18" WIDE CURB CUT CENTERED ON TREE WELL (SEE DETAIL D-D) SPLASH PAD PER GS-5.06 15' MARINA STRAWBERRY TREE DIAMETER CANOPY STREET TREE WITH 353 CF MIN STRUCTURAL SOIL LIMITS OF 30 MIL PLASTIC IMPERMEABLE LINER ALONG SIDES OF STRUCTURAL SOIL 6" THICK, 12" DEEPENED EDGE SIDEWALK TREATMENT, SEE SECTION B-B BELOW CONSTRUCT CONTIGUOUS PCC SIDEWALK 4.0' CLEAR MIN LIMITS OF STRUCTURAL SOIL BELOW (4' DEEP X 9.5' X 11.4') 10.0' 11 . 4 ' PL / ROW E E 6" PCC CURB & GUTTER DEEP ROOT TREE BUBBLER PER SDRSD DWG I-4 6" PCC C&G PER SDRSD G-2 STREET FLOW COMPACTED SUBGRADE CURB CUT PER DETAIL THIS SHEET 30 MIL PLASTIC IMPERMEABLE LINER AND ROOT BARRIER SPLASH PAD PER GS-5.06 12" 12" 2" UNCOMPACTED SUBGRADE PL / ROW PCC SIDEWALK PER SDRSD G-7 8.75' LIMITS OF STRUCTURAL SOIL 4" X 8" SMOOTH DOWELS @ 18" OC, GREASED ON ONE END 9" X 30" TREE GRATE SUPPORT 30 MIL PLASTIC IMPERMEABLE LINER ROOT BARRIER PER SDRSD L-6 1:1 CUT COMPACTED SOIL SUBGRADE 30 MIL PLASTIC IMPERMEABLE LINER 48" DEEP STRUCTURAL SOIL; STRUCTURAL PER A-1 STRUCTURAL SOIL OR APPROVED EQUAL 6" SAND FILTER LAYER ROOT BARRIER PER SDRSD L-6 STREET FLOW COMPACTED SUBGRADE 6" PCC CURB AND GUTTER PER SDRSD G-2 4" X 8" SMOOTH DOWELS @ 18" OC, GREASED ON ONE END, TYP. ALL SIDES PER SDC GS DS GS-1.00 3" MIN MULCH LAYER 4" OPENING FOR DRAINAGE 4"#4 @ 18" O.C. BOTH WAYS PER SDC GS DS GS 1-.00 9" X 30" TREE GRATE SUPPORT 3" 9" STREET FLOW CURB CUT PER DETAIL THIS SHEET 30 MIL PLASTIC IMPERMEABLE LINER 48" DEEP STRUCTURAL SOIL; STRUCTURAL PER A-1 STRUCTURAL SOIL OR APPROVED EQUALDEEP ROOT TREE BUBBLER PER SDRSD DWG I-4 6" SAND FILTER LAYER ROOT BARRIER PER SDRSD L-6 UNCOMPACTED SUBGRADE 9" PCC SIDEWALK PER SDRSD G-7 PL / ROW SPLASH PAD PER SDC GS DS GS-5.06 TYPE 1 30 MIL PLASTIC IMPERMEABLE LINER ROOT BARRIER PER SDRSD L-6 4' X 8' COHO TREE GATE FRAME BY URBAN ACCESSORIES WITH COATED IRON AND MATT BLACK FINISH; INSTALL GRATE PER MANUFACTURER'S SPECIFICATIONS COMPACTED SUBGRADE 1:1 CUT 6" PCC C&G PER SDRSD G-2 4.0' TREE GRATE COVER 8.75' LIMITS OF STRUCTURAL SOIL ROOT BALL 4' X 8' COHO TREE GATE FRAME WITH COATED IRON IN MATT BLACK FINISH BY URBAN ACCESSORIES; INSTALL GRATE PER MANUFACTER'S SPECIFICATIONS 3" MIN MULCH LAYER 9" 48" DEEP STRUCTURAL SOIL; STRUCTURAL PER A-1 STRUCTURAL SOIL OR APPROVED EQUAL UNCOMPACTED SUBGRADE DEEP ROOT TREE BUBBLER PER SDRSD DWG I-4 #4 @ 18" O.C. BOTH WAYS PER SDC GS DS GS 1-.009" 30" 3" 6" SAND FILTER LAYER 30 MIL PLASTIC IMPERMEABLE LINER ROOT BARRIER PER SDRSD L-6 9" X 30" TREE GRATE SUPPORT; COMPACT SOIL UNDER GRATE SUPPORT 30 MIL PLASTIC IMPERMEABLE LINER ROOT BARRIER PER SDRSD L-6 INSTALL 30 MIL PLASTIC IMPERMEABLE LINER WHERE CONCRETE IS POURED OVER ENGINEERED SOIL (TYP.) 8.0' TREE GRATE COVER 9.0' 12.2' LIMITS OF STRUCTURAL SOIL 9" H&A TC L _____ l_ ~•·:•/ .,/.J,. / I· :; \ / 1 • I I I v- r----....,_______,..I _l_ r---1 I ---r-----'-1 - _L __ /1'\ DA1E INITIAL ENGINEER OF WORK \'~Of ESS / a¼ ~ <,.,~ G L-4/f,, '( P L S A /J' -A..'-<l'o ~ "' ... '1-i:' "' --2' "' No. 80Z356 ,,, ,~r,~~ P.E. EXP. 'ti w ~ ~ - C/V\\. ~/,~ PLSAENGINEERING.COM .. JJF CALI~ I SHEET I I SHEETS I CITY OF CARLSBAD ENGINEERING DEPARlMENT IMPROVEMENT PLANS FOR: PUD 2023-0007 CDP 2023-0058 APPROVED:TIMOTHY 0. CARROLL PRINCl'AL ENGINEER RCE S53111 EXP.12/31/28 DA1E I PROJECT NO. I DRAWING NO. DA1E INITIAL DA1E INITIAL RVWD BY: REVISION DESCRIPTION DlHER APPROVAL ClY APPROVAL CHKD BY: Docusign Envelope ID: EC7F77F8-CD7A-4270-8873-F956CDAC434F 4/30/2026