GENERAL NOTES
1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD
REGARDING IMPROVEMENTS SHOWN ON THIS SET OF PLANS.
2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL
CODE. RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL
DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN
RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED.
3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF-WORK FROM
RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING
CONSTRUCT/ON. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR
APPROVAL
4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE
PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE MUST BE
FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN
THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRENCE OF LIABILITY. THE INSURANCE
COMPANY WRITING THE POLICY MUST HAVE A RA TING OF "A-" OR BETTER AND A SIZE CA TE GORY
OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RA TING GUIDE
5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER
APPROPRIATE AGENCIES.
6. REVISION OF THESE PLANS MAY BE REQUIRED IF THE PROPOSED IMPROVEMENTS ARE NOT
CONSTRUCTED PRIOR TO THE DEADLINE DATE OF THE IMPROVEMENT AGREEMENT.
7. NO REVISIONS WILL BE MADE TD THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY
ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATESHEETOFTHEPLANS
AND TITLE SHEET.
8. ORJGINAL ORA WINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY
ENGINEER.
9. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE
ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY.
10. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE
AT ALL TIMES DURING CONSTRUCT/ON.
11. WHERE TRENCHES ARE WITHIN C/TYEASEMENTS,ASO/LSREPORTCOMPRISEDOF: (A) SUMMARY
SHEET, (BJ LABORATORY WORK SHEETS AND (CJ COMPACTION CURVES, SHALL BE SUBMITTED BY
A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA. PR/NC/PALLY DOING BUSINESS IN THE
FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY
ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF COMPLETION OF FIELD TESTS. THE
WRITTEN FIELD COMPACTION REPORT(S) SHALL BE IMMEDIATELY SUBMITTED TO THE CITY
ENGINEERING INSPECTOR UPON COMPLETION OF THE FIELD TESTS.
12. A PRECONSTRUCT/ON MEETING SHALL BE HELD PRIOR TO THE BEGINNING OF WORK AND SHALL BE
ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION,
SUPERVISION TESTING AND ALL OTHER ASPECTS OF THE WORK THE CONTRACTOR SHALL
SCHEDULE THE MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 A TLEAST FIVE (5)
WORKING DAYS PRIOR TO STARTING CONSTRUCT/ON. APPROVED DRAWINGS MUST BE AVAILABLE
PRIOR TO SCHEDULING.
13. ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCT/ON MEETING WILL BE MADE BY
CAWNG THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT 1760/ 438-3891. INSPECTION
REQUESTS MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE WORK DAY BEFORE THE INSPECTION IS
NFFDEQ INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE
REQUESTS MADE AFTER 2:00 PM. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER.
14. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN,
CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY
RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEAL TH
STANDARDS, LAWS AND REGULATIONS.
15. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO
THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING
SLOPE OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF
CAVING GROUNDDUR/NG THE EXCAVATION OF SUCH TRENCHORTRENCHESORDUR/NGTHEPIPE
INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5) OR
MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO
EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE
CONSTRUCTION SAFETY ORDERS TITLE 8 CALIFORNIA ADMINISTRATIVE CODE THE PLAN SHALL
BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA
EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION.
16. NO BLASTING SHALL BE COMMENCED WITHOUT A CITY ENGINEER APPROVED BLASTING PROGRAM
AND BLASTING PERMIT.
17. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK ZONE DURING
CONSTRUCTION OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL NOTIFY THE
CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN
AUTHORITY FROM THE CITY ENGINEER TO DO SO.
18. ALL OPERA T/ONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP,
REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT,
CONSTRUCT/ON EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED
TO THE PERIOD BETWEEN 7:00 A.M. AND 6:00 PM. EACH DAY, MONDAY THRU FRIDAY AND NO
EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLi DAYS. (A
LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERJNG DEPARTMENT COUNTER.)
19. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY INSPECTOR FOR
APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK THE CONTRACTOR SHALL BE
RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTE OR ADJACENT
STREETS AS A RESULT OF THE GRADING OPERA T/ON.
20.IMPORT MATERIAL SHALL BE OBTAINED FROM,ANDWASTE MATERIAL SHALL BE DEPOSITED AT, A
SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESl'ONSIBLE FOR ANY
DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF
THE GRADING OPERATION.
21. THE EXISTENCE AND LOCATION OF UTILITYSTRUCTURESANDFACILITIES SHOWN ON THE
CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENTION IS
CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS
REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE
PLANS AND ANY OTHER EXJSTING FACILITIES OR STRUCTURES NOT SHOWN.
22. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES(ABOVEGROUNDAND
UNDERGROUND) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF THE CONSTRUCTION TO
PERMIT THE REVISIONS OF THE CONSTRUCT/ON PLANS IF IT IS FOUND THAT THE ACTUAL LOCA T/ONS
ARE IN CONFLICT WITH THE PROPOSED WORK.
23. THE CONTRACTOR SHALL NOTIFYAFFECTEDUTILITYCOMPANIES(SEEBELOW) AT LEASTTWOFULL
WORKING DAYS PRIOR TO STARTING CONSTRUCT/ON NEAR THEIR FACILITIES AND SHALL
COORDINATE WORK WITH A COMPANY REPRESENTATIVE
UNDERGROUND SERVICE ALERT
SDG&E
AT&T
TIME WARNER CABLE
COX COMMUNICATIONS
CITY OF CARLSBAD(STREETS AND STORM DRAIN)
•CITY OF CARLSBAD(SEWER, WATER & RECLAIMED WATER)
'BUENA SAN/TA TION DISTRICT
'AS APPROPRIATE
(800)422-4133
(800)411-7343
(800)892-0123
(760)438-7741
(619)262-1122
(760)434-2980
(760)438-2722
(760)726-1340 x1330
24./N ACCORDANCE THECITYSTORMWATERSTANDARDS ALL STORM DRAIN INLETS CONSTRUCTEDBY
THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTE DISCHARGE DOWNSTREAM.
STENCILS SHALL BE ADDED TO THE SATISFACTION OF THE CITY ENGINEER.
J:\ACTIVE JOBS\4052 RINCON-270 JUNIPER\CIVIL\DRAWING\IMPROVEMENT PLANS\4052-CV-/P-01-TITLE.DWG
STREET NOTES
1. ACTUAL STRUCTURAL SECTIONS WILL BE DETERMINED AFTER "R" VALUE TESTS HAVE BEEN
CONDUCTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING
BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, ON THE PREPARED BASEMENT SOIL THE "R"
VALUE TESTS AND THE ENGINEERED STRUCTURAL SECTION MUST BE SUBMITTED TO THE
ENGINEERING INSPECTOR FOR REVIEW AND APPROVAL A MINIMUM OF TWO (2) CITY WORKING DAYS
BEFORE THE WORK BEGINS.
2. STREET LIGHTS SHALL BE INSTALLED AS SHOWN ON THESE PLANS, UNDERGROUND CONDUIT RUNS,
SERVICE POINTS AND HAND-HOLES SHALL BE SHOWN ON THE "AS-BUil T' PLANS. NO DIRECT
BURIAL STREET LIGHT FOUNDATIONS WILL BE ALLOWED. ALL LUM/NA/RES SHALL BE ·cur OFF" TYPE
3. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF
CURBS, CROSS GUTTERS OR SURFACING OF STREETS.
4. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED IT SHALL BE REMOVED WITHIN TWENTY FEET
OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER
AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY
ENGINEER.
5. WHEELCHAIR RAMPS SHALL BE INSTALLED PER REQUIREMENTS OF TITLE 24, CALIFORNIA
ADMINISTRATIVE CODE.
6. STREET TREES SHALL BE INSTALLED PER SECTION VI OF THE CITY OF CARLSBAD LANDSCAPE MANUAL
7. FIRE HYDRANT MARKERS SHALL BE PLACED IN THE STREET WITHIN THE LIMITS OF WORK OF THIS PLAN
PER SDRS DWG M19.
8. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTURBED BY THIS WORK SHALL BE
REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS
ACT.
9. TWO (2) SETS OF SURVEY (CUT) SHEETS SHALL BE PROVIDED TO THE CITY ENGINEERING INSPECTOR.
10. STREET LIGHTS SHALL BE 4,000 LUMEN (25-32 WA TT) #ERLI-0-04-C5-30-A-GRA Y-L4 GE-EVOLVE-LED.
SEWER NOTES
1. SEWER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CITY OF
CARLSBAD ENGINEERING STANDARDS (LATEST EDITION), VOLUME 1-GENERAL DESIGN STANDARDS,
CHAPTER 6-DESIGN CRITERIA FOR GRAVITY SEWER LINES AND APPURTENANCES, AND VOLUME 3 -
STANDARD DRAWINGS AND NOTES AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTION, LA TEST EDITION (GREEN BOOK).
2. BEFORE ANY CONNECTION TO THE CITY'S EXISTING SYSTEM, A PERMIT SHALL BE OBTAINED FROM
THE CITY. IT MUST BE SIGNED AND APPROVED BY THE CITY ENGINEER OR DESIGNEE.
3. BEFORE CONSTRUCTION BEGINS IN ANY PUBLIC RIGHT OF WAY, A CITY RIGHT OF WAY PERMIT SHALL
BE REQUIRED.
WATER NOTES
1. WATER & RECYCLED WATER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE
WITH THE "CITY OF CARLSBAD ENGINEERING STANDARDS" (LA TEST EDITION) VOLUMES 2 & 3.
2. BEFORE ANY CONNECTION OR SHUT DOWN OF VALVES ON EXISTING C.M. W.D. LINES, A PERMIT
SHALL BE OBTAINEDFROMTHEC.M.W.D. OFFICE AND MUST BE SIGNED AND APPROVED BY THE
CITY OF CARLSBAD'S DEPUTY CITY ENGINEER AND THE UTILITY OPERATIONS' PUBLIC WORKS MANAGER.
3. ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCT/ON MEETING WILL BE MADE BY
CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INSPECTION
REQUESTS MUST BE RECEIVED PRIOR TO 2:00 PM. ON THE WORK DAY BEFORE THE INSPECTION IS
NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE.
REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER.
4. NO TREES OR STRUCTURES SHALL BEALLOWEDINTHEWATERLINEEASEMENT,ALL EXISTING
TREES AND STRUCTURES SHALL BE REMOVED PRJOR TO COMMENCEMENT OF WORK -ANY
EXCEPTIONS SHALL REQUIRE WRITTEN PERMISSION FROM THE DISTRICT ENGINEER.
5. ALL BURIED COPPER PIPING AND APPURTENANCES SHALL BE PROTECTED BY MEANS OF CATHODIC
PROTECTION. IF DEVELOPER/OWNER CONDUCTS A SOILS TEST REPORT AND DEMONSTRATES THAT
PROTECTION CAN BE PERFORMED IN ANOTHER MANNER, THE DISTRICT ENGINEER WILL CONSIDER
AN ALTERNATIVE FORM OF PROTECTION.
6. THE EXACT HORIZONTAL AND VERTICALALIGNMENTANDTYPEOFMATERIALSOFTHE FIRE LINE
LOCATED BETWEEN THE DETECTOR CHECK VALVE AND BUILDING SHALL BE DETERMINED BY THE CITY
OF CARLSBAD FIRE MARSHAL
7. ALL POTABLE WATER SERVICES SHALLBE1"AND ALL METERS SHALLBE1"(UNLESSOTHERWISE
NOTED ON PLANS).
8. ALL WATER METER BOXES SHALL BE 17" X 30" X 12" POLYMER CONCRETE AS MANUFACTURED BY
ARMORCAST OR EQUAL
9. MINIMUM SPACING BETWEEN POTABLE WATER SERVICESANDSEWERLATERALSSHALLBE10FEET.
10. THE TOP OF WATER METER BOXES SHALL BE FLUSH WITH THE FINISHED SURFACE GRADE.
11. CONSTRUCTION OF WATER MAINS AND RECYCLED WATER MAINS SHALL ADHERE TO THE "CRITERIA FOR
THE SEPARATION OF WATER MAINS AND SANITARY SEWERS" PUBLISHED BY THE STATE OF CALIFORNIA'S
DEPARTMENT OF HEALTH SERVICES.
12. AXIAL DEFLECTION AT THE PIPE JOINTS IS NOT ALLOWED. THE USE OF A HIGH-DEFLECTION COUPLING
ATAPIPEJO/NTMAYBEPERMITTED BYTHE/NSPECTORONA CASE BY CASE BASIS NOT TO EXCEED
4 DEGREES TOTAL DEFLECTION PER COUPLING (2 DEGREES/EACH GASKET). USE CERTAINTEED
"VINYL-IRON" H.D. FOR C900.
13. BEFORE CONSTRUCT/ON BEGINS IN ANY PUBLICR/GHTOFWAY,ACITYRIGHTOFWAYPERM/TSHALL
BE REQUIRED.
14. NO CUTTING OR SNAPPING OF ASBESTOS CEMENT PIPE (ACP) IS PERMITTED. CONTRACTOR SHALL
REMOVE ACP TO NEAREST COUPLING AND INSTALL ACP X PVC ADAPTORS AND THE NECESSARY PVC
SIZE AND CLASS PIPE TO INSTALL THE TEE AT THE STATION
15. PRIOR TO BACKFILL, INSTALL TRACER WIRE ON TOP OF PIPE AND SECURE IN PLACE WITH 2-/NCH WIDE
PLASTIC ADHESIVE TAPE AT MAXIMUM 10-FOOT INTERVALS. WIRE TO ENTER VALVE STANDS BY MEANS
OF DRILLED HOLE IN PIPE STAND WALL JUST BELOW 4TTBOX WIRE IS NOT TO INTERFERE WITH VALVE
NUT OPERATION. RUN TRACER WIRE CONTINUOUSLY ALONG PIPE AND TERMINATE IN ADJACENT VALVE
BOXES FOR BURIED ASSEMBLIES OR BURIED VALVES. WHERE BURIED SPLICES OCCUR, USE AN
ELECTRICAL EPOXY RESIN SUCH AS SCOTCHCAST, OR APPROVED EQUAL PROVIDE 24 INCHES OF
COILED WIRE AT ACCESS POINTS FOR ATTACHMENTS OF PIPE LOCATING EQUIPMENT. EACH
INSTALLED RUN OF PIPE SHALL BE CAPABLE OF BEING LOCATED USING THE TRACER WIRE. PROTECT
WIRE INSULATION FROM DAMAGE DURING INSTALLATION AND BACKFILLING. WIRE INSULATION THAT IS
BROKEN, CUT, OR DAMAGED SHALL BE REPLACED. TRACER WIRE SHALL BE AWG NO. 8 STRANDED
COPPER WIRE WITH HIGH MOLECULAR WEIGHT POLYETHYLENE (HMW/PE) INSULATION SPECIF/CALLY
DESIGNED FOR DIRECT BURIAL IN CORROSIVE SOIL OR WATER. POLYETHYLENE /NSULA T/ON SHALL
CONFORM TO ASTM D 1248, TYPE 1, CLASS C. WIRES WITH CUT OR DAMAGED INSULATION ARE NOT
ACCEPTABLE AND REPLACEMENT OF THE ENTIRE WIRE WHICH HAS BEEN DAMAGED WILL BE REQUIRED
AT THE CONTRACTOR'S EXPENSE.
16. CONTRACTOR TO SUBMIT E-28 FORM TO CM&/, MINIMUM 2 WEEKS PRIOR TO SCHEDULED WATER
SHUTDOWN.
SIGNING AND STRIPING NOTES
1. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL SIGNING AND STRIPING.
2. SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (LA TEST VERSION), CAL TRANS STANDARD SPECIF/CATIONS (JULY 2006 OR LA TEST
VERSION THEREOF), THESE PLANS AND THE SPECIAL PROVISIONS.
3. ALL SIGNING AND STRIPING IS SUBJECT TO THE APPROVAL OF THE TRANSPORTATION DIRECTOR OR HIS
REPRESENTATIVE, PRIOR TO INSTALLATION.
4. ANY DEVIATION FROM THESE SIGNING AND STRIPING PLANS SHALL BE APPROVED BY THE ENGINEER OF WORK
AND PUBLIC WORKS DIRECTOR PRIOR TO ANY CHANGE IN THE FIELD.
5. ALL SIGNING AND STRIPING SHALL BE REFLECTIVE PER CAL TRANS SPECIF/CATIONS. STRIPING SHALL BE
REPAINTED TWO WEEKS AFTER INITIAL PAINTING. SIGNING SHALL USE ENCAPSULATED LENS REFLECTIVE
SHEETING (HIGH INTENSITY OR EQUAL).
6. PRIOR TO FINAL ACCEPTANCE OF STREET IMPROVEMENTS, ALL STREET STRJPING AND AND MARKINGS
WITHIN A 500' PERIMETER OF THE CONSTRUCT/ON PROJECT WILL BE RESTORED TO A "LIKE NEW" CONDITION,
IN A MANNER MEETING THE APPROVAL OF THE CITY INSPECTOR.
7. EXACT LOCATION OF STRIPING AND STOP LIMITLINESSHALLBEAPPROVEDBYTHETRANSPORTATION
DIRECTOR OR HIS REPRESENTATIVE PRIOR TO INSTALLATION.
8. CONTRACTOR SHALL REMOVE ALL CONFLICTING PAINTED LINES, MARKINGS AND PAVEMENTLEGENDS BY
GRINDING. DEBRIS SHALL BE PROMPTLY REMOVED BY THE CONTRACTOR.
9. ALL PAVEMENT LEGENDS SHALL BE THE LA TEST VERSION OFTHE CAL TRANS METRIC STENCILS.
10. LIMIT LINES AND CROSSWALKS SHALL BE FIELD LOCATED. CROSSWALKS SHALL HAVE 10' INSIDE DIMENSION
UNLESS OTHERWISE SPECIFIED.
11. ALL CROSSWALKS, LIMIT LINES, STOP BARS, PAVEMENT ARROWS AND PAVEMENT LEGENDS SHALL BE
THERMOPLASTIC UNLESS OTHERWISE SPECIFIED.
12. FIRE HYDRANT PAVEMENT MARKERS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC
CONTROL DEVICES (LA TEST VERSION) AND SAN DIEGO REGIONAL STANDARD DRAWING M-19.
13. ALL MEDIAN NOSES AND FLARES SHALL BE PAINTED YELLOW.
14. ALL SIGNS SHALL BE STANDARD SIZE AS SHOWN IN THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL
DEVICES (LA TEST VERSION) UNLESS OTHERWISE SPECIFIED.
15. SIGN POSTS SHALL BE SQUARE PERFORATED STEEL TUBING WITH BREAKAWAY BASE PER SAN DIEGO
REGIONAL STANDARD DRAWING M-45.
16. WHEN A SIGN IS A TT ACHED TO A POLE, IT SHALL BE MOUNTED USING A STANDARD CITY OF CARLSBAD
MOUNTING BRACKET WITH STRAPS.
17. EXISTING SIGNS REMOVED BY THE CONTRACTOR SHALL BE DELIVERED BY THE CONTRACTOR TO THE CITY OF
CARLSBAD PUBLIC WORKS YARD AT 405 OAK AVENUE.
18. ALL SIGNS SHOWN ON THESE PLANS SHALL BE NEW SIGNS PROVIDED AND INSTALLED BY THE CONTRACTOR
EXCEPT THOSE SIGNS SPECIFICALLY SHOWN AS EXJSTING TO BE RELOCATED OR TO REMAIN.
19. (IF NECESSARY) WHERE R4-7 SIGN AND OM1-3 OBJECT MARKER ARE TO BE INSTALLED IN A 2-FOOTWIDE
MEDIAN NOSE, THE R4-7 SIGN SHALL BE 18"X24" AND THE OM1-3 OBJECT MARKER SHALL BE 12"X12"
DECLARATION OF RESPONSIBLE CHARGE (SHEETS 1-4)
I HEREBY DECLARE THAT/ AMTHEENGINEEROFWORKFOR THIS PROJECT, THAT /HAVE EXERCISED
RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS
AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS.
I UNDERSTAND THATTHECHECKOFPROJECTDRAW/NGSAND SPECIFICATIONS BY THE CITY OF CARLSBAD
DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN.
DATE: ____ _
~R~N,R.CE
ofESS/or-i
G L-41#, ~o. ~
R.C.E. NO:_~8=03=5~6 _____________ _ No. 80356
REG/STRA T/ON EXP/RAT/ON DA "~E·-~12~-3~1-=20=2=6 ______ _
FIRM: PASCO. LARET, SUITER, AND ASSOC/A TES, INC.
!J9DRESS: 1911 SAND/EGO AVE, SUITE 100 C/V\\.. ~
CITY, STATE: SAN DIEGO, CA 92110
TELEPHONE: (858) 259-8212
OWNER'S SWPPP CERTIFICATE
I (WE) ACKNOWLEDGE THAT I (WE) MUST:
(1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPs) DURING CONSTRUCTION ACTIVITIES TO THE
MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOB/LIZA TION OF POLLUTANTS SUCH AS
SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCT/ON RELATED
POLLUTANTS; AND
(2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED CONSTRUCTION SWPPP
THROUGHOUT THE DURATION OF THE CONSTRUCT/ON ACTIVITIES UNTIL THE CONSTRUCTION
WORK IS COMPLETE AND SIGNED OFF BY THE CITY OF CARLSBAD.
IF THIS PROJECT/DEVELOPMENT IS SUBJECT TOA STATE-REGULATED SWPPP, I (WE) ALSO AGREE A
QUALIFIED SWPPP PRACTITIONER (QSP) HAS BEEN OR WILL BE RETAINED TO SUPERVISE
IMPLEMENT AT/ON OF THE SWPPP IN ACCORDANCE WITH THE CALIFORNIA CONSTRUCT/ON ORDER AND
MUNICIPAL PERMIT, LA TEST VERSION.
KRIS C,tMPBELL FOR: DATE
TOLL WEST COASTLLC
SOURCE OF TOPOGRAPHY
TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERA TED BY FIELD SURVEY METHODS FROM
INFORMATION GATHERED ON: JULY 6, 2023
BY: PASCO, LARET, SUITER & ASSOCIATES
TOPOGRAPHY SHOWN HEREON CONFORMS TO NA T/ONAL MAP ACCURACY STANDARDS
PROJECT LOCATION
THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S): 204-240-22
THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N 358 E 1665
(CCS 83)
ADDRESS: 270 JUNIPER AVENUE, CARLSBAD, CA 92008
POST-CONSTRUCTION BMP TABLE
STORMWA TER REQUIREMENTS THAT APPLY: EXEMPT FROM EXEMPT FROM
CITY OF OCEANSIDE
HIGHWAY '8
PACIFIC
OCEAN
NOT TO SCALE
CITY OF VISTA
CITY OF
.K""-,..., SAN MARCOS
CITY OF ENCINITAS
VICINITY MAP
PROJECT ADDRESS
270 JUNIPER AVENUE
CARLSBAD, CA 92008
APN: 204-240-22
REFERENCE DRAWINGS
CR 14995
PM 12335
MAP 12987
MAP 1747
PM 16289
MAP1803
CR 15001
PM 16596
MAP7961
PM7248
DWG 117-2
DWG 123-7
DWG 170-6
DWG 551-3A
INDEX OF SHEETS
1 TITLE SHEET
N.T.S.
2 JUNIPER AVENUE IMPROVEMENT PLAN
3-4 SECTIONS AND DETAILS
LEGAL DESCRIPTION
ABBREVIATION LEGEND
EG = EXISTING GRADE
FS = FINISHED SURFACE
FG = FINISHED GRADE
FL= FLOWLINE
FF= FINISHED FLOOR
GF = GARAGE FACE
IE= INVERT ELEVATION
LA = LANDSCAPE AREA
TB = TOP OF BERM
TC = TOP OF CURB
TG = TOP OF GRATE ELEVATION
TP = TOP OF PIPE
RJ = RESTRAINED JOINT
RIM= TOP OF RIM ELEVATION
EXISTING GRADE
FYSB = FRONT YARD SETBACK
RYSB = REAR YARD SETBACK
SYSB = SIDE YARD SETBACK
LOT 2 OF BLOCK "Q" OF PALISADES NO.2, IN THE CITY OF CARLSBAD,
COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO
MAP THEREOF NO. 1803 FILED IN THE OFFICE OF THE COUNTY
RECORDER OF SAN DIEGO COUNTY, AUGUST 25, 1924.
OWNER INFORMATION DEVELOPER
WORK TO BE DONE
THE IMPROVEMENT WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS,
CURRENT AT THE TIME OF CONSTRUCT/ON, AS DIRECTED BY THE CITY ENGINEER.
1. CARLSBAD MUNICIPAL CODE
2. CITY OF CARLSBAD ENGINEERING STANDARDS
3. THIS SET OF PLANS
4. RESOLUTION NO 7533 DATED DECEMBER 18, 2024
5. THE STANDARD SPECIF/CA T/ONS FOR PUBLIC
WORKS CONSTRUCTION (GREEN BOOK)
6. SOILS REPORT AND RECOMMENDATIONS BY LGC
VALLEY, INC.: JOB. NO. 254003-01 DATED 10/26/2023,
06/07/2024, 04/04/2025, 08/06/2025, AND 12/04/2025
7. SAN DIEGO REGIONAL STANDARD DRAWINGS AND
AS MAY BE MODIFIED BY THE CITY OF CARLSBAD
STANDARDS.
8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT
PERMIT CONDITIONS DATED NIA
9. STORM WATER POLLUTION PREVENTION PLAN (TIER 2)
PREPARED BY: PLSA . (SEE DWG 551-3A)
10. STORM WATER QUALITY MANAGEMENT PLAN
PREPARED BY: PLSA DA TED: OCTOBER 2025
11. CALIFORNIA STORM WATER QUALITY ASSOCIATION
BMP CONSTRUCT/ON HANDBOOK AND CAL TRANS
CONSTRUCT/ON SITE BMP MANUAL
LEGEND
DESCRIPTION
PROPERTY LINE
RIGHT-OF-WAY
ADJACENT LOT LINE
CENTERLINE OF ROAD
EXISTING CONTOUR
PROPOSED CONTOUR
EXISTING EDGE OF PAVEMENT
EXISTING WATER MAIN (SIZE AND
MATERIAL PER PLAN)
EXISTING WATER SERVICE (TO BE
ABANDONED)
EXISTING SEWER MAIN (SIZE AND
MATERIAL PER PLAN)
EXITING GAS MAIN (SIZE PER PLAN)
PROPOSED 6" PCC CURB AND GUTTER
PROPOSED TYPE A 5" AC BERM
PROPOSED 6" PVC SEWER LATERAL
AND CLEANOUT
PROPOSED 3" DOMESTIC WATER
SERVICE WI 3" METER AND BACKFLOW
PROPOSED 1" IRRIGATION SERVICE WI
1 • METER AND BACKFLOW
PROPOSED 6" FIRE WATER SERVICE &
BACKFLOW
PROPOSED AC SAWCUT
PROPOSED TYPE A4 STORM DRAIN
CLEANOUT
PROPOSED 12" RCP STORM DRAIN
CAL TRANS VEHICULAR STOPPING
SIGHT DISTANCE VIEW CORRJDOR
STD.
SDRSD G-5'
CARLSBAD
S-7 & S-8
CMWD W-7"
&W-8
CMWD W-3"
&W-8
CMWDW-9"
SDRSDD-09
SYMBOL QUANTITY -----------
140
140
Ill
w w
w-- w--~ 1 EA
s s
G G
125LF
22LF
s s 0 1 EA
w w I ◄ 1 EA
w w ------0--0 1 EA
w w -----,:;jjjjl 1 EA
150LF
6] 2EA
32LFPVT
45LFPUB
-·--·--
NAME: KRIS CAMPBELL FOR: TOLL WEST COAST LLC
A DELAWARE LIMITED LIABILITY
NAME: KRIS Co\MPBELL FOR: TOLL WEST COAST LLC
A DELA WARE LIMITED LIABILITY
PROPOSED TRENCHING AND CARLSBAD
RESURFACING WI AC PAVEMENT GS-26 & GS-28 J//////////////1
I~ •· -•-• • • ~---•· I
180LF
COMPANY
ADDRESS: 350 COMMERCE SUITE 200
/RV/NE, CA 92602
PHONE NO.: (714) 347-1375
COMPANY
ADDRESS: 350 COMMERCE SUITE 200
/RV/NE, CA 92602
PHONE NO.: (714) 347-1375
BENCH MARK
DESCRIPTION: 2.5 INCH DISK ---------------------LO CA Tl ON: IN THE SOUTHEAST CORNER OFA VAULT ADJACENT TO THE NORTHEAST
CORNER OF THE NORTHBOUND COAST HIGHWAY 101 BRIDGE OVER THE
AGUA HEDIONA LAGOON 0. 1 MILES SOUTH OF TAMARACK AVENUE, 38-FT
EAST OF THE EDGE OF PAVEMENT
RECORDED: 2002 PER ROS 17271
ELEVATION: 26.52' DA TUM: NGVD 29 -----------
BASIS OF BEARINGS
THE CALIFORNIA COORDINATE SYSTEM OF 1983 (CCS-83), ZONE 6, EPOCH 1991.35,
GRID BEARING N 66' 04' 32" E BETWEEN STATION "CLSB 141" AND STATION "CLSB 119" . .
AS SAID STATIONS ARE PUBLISHED IN THE CITY OF CARLSBAD SURVEY CONTROL
NETWORK PER RECORD OF SURVEY MAP NO. 17271, FILED IN THE OFFICE OF THE SAN
DIEGO COUNTY RECORDER ON FEBRUARY 8, 2002.
PROPOSED 4" PCC SIDEWALK/
PAVEMENT
PROPOSED 2" AC GRIND AND OVERLAY
PROPOSED MIN. 4" AC OVER 6" AB'""
PROPOSED 15-FT DIAMETER TREE
CANOPY TREE WELL BMP
PER DETAIL
SHEET4
600SF
2,930SF
1,140 SF
1 EA
PROPOSED TYPE B CURB INLET SDRSD D-02" 1 EA
PROPOSED PCC DRIVEWAY APRON 255SF
ALL STANDARD DRAWINGS ARE CITY OF CARLSBAD DRAWINGS (SDRSD) UNLESS
NOTED OTHERWISE:
ABBREV/A TION:
SDRSD -SAN DIEGO REGIONAL STANDARD DRAWING
CMWD -CARLSBAD MUNICIPAL WATER DISTRICT
""ACTUAL SECTION TO BE DETERMINED BY GEOTECH
ENGINEER BASED ON R-VAULE TEST RESULTS
PLSA 1r,-~
PLSAENGINEERING.COM
I SH~T I
• SAN DIEGO REGIONAL STANDARD DRAWING
" CARLSBAD MUNICIPAL WATER DISTRICT STANDARD DRAWING
••• SDRSD AS MODIFIED BY CITY OF CARLSBAD
"AS BUil T"
P.E. EXP. DATE
REVIEWED BY:
INSPECTOR DATE
I SHEETS I CITY OF CARLSBAD
ENGINEERING DEPARlMENT
IMPROVEMENT PLANS FOR:
JUNIPER COAST HOMES
270 JUNIPER AVENUE PUD 2023-0007
IMP 2025-0001 TITLE SHEET CDP 2023-0058
APPROVED:TIMOTI-IY 0. CARROLL
TRASH CAPTURE? HYDROMOD/F/CA T/ON? PRINCl'AL ENGINEER RCE 553111 EXP. 12/31 /26 DA1E
tsj STANDARD STORMWATER REQUIREMENTS 11, PROJECT NO. DRAWING NO. tsj YES ~ YES DA1E INITIAL DA1E INITIAL DA1E INITIAL RVWD BY: PRIORITY PROJECT REQUIREMENTS NO NO REVISION DESCRIPTION CHKD BY: CT 2023-0005 551-3 ENGINEER Of WORK OlHER APPROVAL CllY APPROVAL
PLSA4052
Docusign Envelope ID: EC7F77F8-CD7A-4270-8873-F956CDAC434F
4/30/2026
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
19
1
1
S
A
N
D
I
E
G
O
A
V
E
N
U
E
,
S
A
N
D
I
E
G
O
C
A
9
2
1
1
0
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
"AS BUILT"
DATE
INSPECTOR DATE
REVIEWED BY:
IMP 2025-0001
551-3
JUNIPER COAST HOMES
270 JUNIPER AVENUE
CT 2023-0005
PLSA 4052
4
GRAPHIC SCALE: 1" = 10'
0 10'20'30'
J:\ACTIVE JOBS\4052 RINCON-270 JUNIPER\CIVIL\DRAWING\IMPROVEMENT PLANS
SA
V
E
D
A
T
E
:
20
2
6
-
3
-
2
5
-
P
L
O
T
D
A
T
E
:
2
0
2
6
-
4
-
8
1
2
:
4
9
P
M
-
F
I
L
E
N
A
M
E
:
J
:
\
A
C
T
I
V
E
J
O
B
S
\
4
0
5
2
R
I
N
C
O
N
-
2
7
0
J
U
N
I
P
E
R
\
C
I
V
I
L
\
D
R
A
W
I
N
G
\
I
M
P
R
O
V
E
M
E
N
T
P
L
A
N
S
\
4
0
5
2
-
C
V
-
I
P
-
0
2
-
J
N
P
R
.
d
w
g
JUNIPER AVE CENTER LINE DATA TABLE
#BEARING / DELTA LENGTH RADIUS
862.041 -N 55° 55' 48" E
ALL EXISTING MONUMENTS TO BE
PROTECTED IN PLACE. ANY MONUMENTS
DESTROY DURING CONSTRUCTION SHALL
BE REPLACED BY A LICENSED SURVEYOR
AND PROPER DOCUMENTATION SHALL BE
FILED WITH THE COUNTY RECORDER
CURB & GUTTER DATA TABLE
#BEARING / DELTA LENGTH RADIUS
2
1
REMARKS
121.48'N 55° 58' 45" E -
3.0'-
3
6" C&G SDRSD G-2
21.56'N 59° 30' 54" E -6" TYPE A AC BERM
SDRSD G-5
PLAN VIEW - JUNIPER AVE IMPROVEMENTS
SCALE: 1" = 10'
2
JUNIPER AVE. IMPROVEMENTS
1. UTILITIES ARE KNOWN TO EXIST IN THE AREA. INFORMATION SHOWN HEREON IS PER BEST AVAILABLE RECORD
INFORMATION. EXACT HORIZONTAL AND VERTICAL LOCATION OF EXISTING UTILITIES UNKNOWN. CONTRACTOR
TO VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO ORDERING MATERIALS AND CONSTRUCTION.
CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD OF ANY DISCREPANCIES UPON DISCOVERY.
2. REMOVE EXISTING WATER SERVICE PER CITY OF CARLSBAD STANDARD SPECIFICATION 15000-3.12.A. REMOVE
EXISTING SEWER LATERAL PER CITY OF CARLSBAD STANDARD 15000-3.12A. EXACT LOCATION OF EXISTING
SEWER LATERAL SERVING PROJECT SITE UNKNOWN; CONTRACTOR TO VERIFY LOCATION IN THE FIELD DURING
CONSTRUCTION
3. EXISTING GAS AND ELECTRICAL SERVICE TO BE REMOVED PER SEPARATE SDGE WORK ORDER.
STREET STA.
OF LAT @ MAIN IE @ MAIN LENGTH DROP TO
MAIN
LAT EL. @
PL (IE)
LAT
SLOPE
GROUND
EL. @ PL
DEPTH BELOW
PL (PL TO IE)
UPSTREAM
C/O RIM EL.
BACKWATER
VALVE REQ'D
4+30.16 44.9'46.3 IE0.70'34.8'51.8 NO5.0'2.0%51.3'
SEWER LATERAL DATA TABLE - 6" PUBLIC SEWER LATERAL
EXISTING SURVEY MONUMENT TO BE PROTECTED IN PLAN.
MONUMENT SHALL BE REPLACED BY A LICENSED LAND SURVEYOR
WHO SHALL FILE A CORNER RECORD WITH COUNTY IF DISTURBED
OR DESTROYED.
INSTALL 6" PVC SEWER LATERAL PER CITY OF CARLSBAD S-7 W/
CUT IN MODIFIED WYE CONNECTION PER S-10 TYPE C USING
MAXADAPTER COUPLINGS PER MODIFIED S-10 DETAIL SHEET 3
2" AC GRIND AND OVERLAY
SAWCUT EXISTING AC PAVEMENT SEE DETAIL SHEET 3
TRENCH AND RESURFACING W/ AC PAVEMENT PER CITY OF
CARLSBAD GS-26, GS-28
INSTALL 1" IRRIGATION SERVICE METER AND BACK FLOW PER
CMWD W-3 & W-6
CONSTRUCTION NOTES
INSTALL 4" DOMESTIC WATER SERVICE, W/ 3" METER AND
BACKFLOW PER CMWD W-7 & W-8; SEE NOTE THIS SHEET
INSTALL 6" FIRE SERVICE AND WILKINS 475DA 6" RDPA OR
APPROVED EQUAL PER CMWD W-9
CONSTRUCT PCC CURB AND GUTTER PER SDRSD G-2 SEE DATA
TABLE THIS SHEET
CONSTRUCT 6" TYPE A AC BERM PER SDRSD G-05
CONSTRUCT 24-FT WIDE PCC DRIVEWAY APRON PER SDRSD G-14A
CONSTRUCT 4" PCC SIDEWALK PER SDRSD G-7
INSTALL TYPE B CURB INLET PER SDRSD D-02 L=5'; WITH
STORMTEK ST3 TRASH CAPTURE DEVICE; TRASH CAPTURE TO BE
MAINTAINED BY HOA
INSTALL TYPE A4 STORM DRAIN CLEAN
OUT PER SDRSD D-9
INSTALL TREE WELL BMP W/ 15-FT DIA.
TREE CANOPY PER DETAIL SHEET 4
(PRIVATELY MAINTAINED)
150-FT STOPPING SIGHT DISTANCE
CORRIDOR PER CALTRANS HIGHWAY
DESIGN MANUAL
MIN. 4" AC OVER 6" CLASS II AB PER
GEOTECH RECOMMENDATION;
STRUCTURAL SECTION TO BE
VERIFIED DURING CONSTRUCTION
BASED ON FIELD TESTED R-VAULE
1
2
3
4
5
7
8
9
10
11
12
15
16
STORM DRAIN DATA TABLE
LINE LENGTH DELTA/BEARING RADIUS
16.85'N 39° 48' 56" W -
SLOPE
1.1%
REMARKS
44.73'1.0%PUB. 12" RCP;
2000 D-LOAD MIN.N 63° 54' 12" E -
12" PVT RCP;
1350 D-LOAD MIN
15.68'N 49° 40' 20" E -3.7%
SITE NOTES WATER MAIN SHUTDOWN NOTE:
EXCEPTED SHUTDOWN OF EXISTING 6" WATER MAIN FOR
INSTALLATION OF WATER SERVICES. CONTRACTOR SHALL SUBMIT
E-28 FORM TO CM&I 2 WEEKS PRIOR TO SCHEDULED SHUTDOWN.
17
**
**
**SEE SHEET
3 FOR SD
PROFILES
1
2
3 12" PVT RCP;
2000 D-LOAD MIN
6
13
0" C&G TRANSITION
TO 6" C&G
EMRA NOTE
ENCROACHMENT AGREEMENT PER DOC. 2025-0010
FOR PRIVATE STORM DRAIN PIPE
1
AC WATER MAIN REPLACEMENT NOTE:
REMOVE AND REPLACE EXISTING 6" AC WATER MAIN TO NEAREST JOINT WITH 6"
PVC WATER MAIN AT ALL NEW POINTS OF CONNECTION PER ENGINEERING STD
VOL. 2-3.3.11.M.. RECONNECT EXISTING WATER SERVICE AFFECTED BY UPSIZING
WITH SADDLE TAP CONNECTION PER CMWD W-13
N 55° 58' 45" E
PROPOSED EASEMENT NOTE
PROPOSED EASEMENT FOR WATER PURPOSES TO
CARLSBAD MUNICIPAL WATER DISTRICT
1
14
4" WATER SERVICE NOTE:
4" WATER SERVICE BETWEEN REDUCER AT GATE
VALVE NEAR TEE TO ABOVE GROUND 90-DEGREE
ELBOW BEND AT METER; 3" AFTER BEND.
**BEARING AREA BASED ON (AWWA C900 CLASS 305 PVC; 200 PSI MAX ASSUMED
TEST PRESSURE PER W-19A W/ SAND AND GRAVEL BACKFILL 1,500 LB/SF);
THRUST BLOCKS PER CMWD W-19 & W-19A
MJ RESTRAINT NOTE:
MECHANICAL JOINT RESTRAINT ON 4" DOMESTIC WATER SERVICE FROM
CONNECTION AT MAIN TO 3" METER; MECHANICAL JOINT RESTRAINT ON
6" FIRE SERVICE FROM CONNECTION AT MAIN TO 6" BACKFLOW
***MIN. ANCHOR BLOCK VOLUME BASED ON WAS DESIGN GUIDELINES (AWWA
C900 CLASS 305 PVC; 150 PSI TEST PRESSURE AND 140 LB/FT^3 BLOCK DENSITY);
X
X
X
X
X
X
X
X
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
C
X
X
X
X
X X X X X
X X X X X X
X
X
X
X
X
X X X X X X X X X X X X X
X
XX
X
X
X
XXXX
X
X
X
X
X
X
X
X X X X X
X
X
X
ELE
:
5
5
.
8
7
I.E:
4
3
.
6
1
55
.
8
4
55
.
7
9
55
55
55
55
S55°58'45"W 122.48'
X
X
X
///
//////
///
///
///////////////
54
/////////
X
X
X
S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S SWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW W
G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
S
SD
SD
SD SD
S
S
W
W
W
W
W
S
S
S
S
G
G
G
G
G
W
W
W
W W W W
W
W
W
W W
G
G
G
G
G
E
WWWW
W
E
E
E EEE
E
IR
R
IR
R
IR
R
IR
R
W W
W
G
G
G
G
G
G
G
G
G
E
E
E
E E E E E E E E E E
3+00 4+00 5+00 6+00
JUNIPER AVENUE
10
.
0
'
4.
0
'
30
.
0
'
20
.
0
'
6.
0
'
LA
ROW ROW
LA
CL CL3+00 4+00 5+00 6+00CLCL
EXISTING GAS MAIN
PER SDGE
EX. 12" C.M.P STORM
DRAIN @0.5% PER
DWG. 123-7
ST
A
.
4
+
2
5
.
6
7
~
1
6
.
2
'
L
T
EX
.
G
R
A
T
E
D
S
D
I
N
L
E
T
TO
B
E
R
E
M
O
V
E
D
(5
0
.
5
T
G
)
(4
7
.
5
I
E
)
4
3
16
5 5
1
1
EX. 6" VC SEWER MAIN
PER DWG. 117-2
EX. 6" AC WATER MAIN
PER DWG. 170-6 EX. PUBLIC STREET
LIGHT TO REMAIN
ST
A
.
4
+
3
8
.
5
0
~
1
6
.
0
'
L
T
51
.
6
5
R
I
M
47
.
5
I
E
I
N
N
O
R
T
H
47
.
5
I
E
I
N
W
E
S
T
(4
7
.
4
5
I
E
O
U
T
E
A
S
T
)
9
12
X'ING 4" DOM. SERVICE 50.5 IE
6" VC SEWER MAIN 45.0 TP
X'ING 6" FIRE SERVICE 48.3 IE
6" VC SEWER MAIN 44.95 TP
X'ING 1" IRR. SERVICE 46.5 TP
12" CMP SD 47.75 IE
X'ING 4" DOM. SERVICE 49.45 IE
12" CMP SD 48.3 TP
X'ING 6" FIRE SERVICE
SERVICE 49.45 IE;
12" CMP SD 48.25 TP
3
LIMITS OF PROPOSED GRIND
AND OVERLAY; C&G TO EDGE
OF PAVEMENT
(51.1 FS)
X'ING 12" RCP SD 47.6 IE
6" PVC SEWER LAT 46.35 TP
ST
A
.
4
+
9
1
.
1
0
~
1
6
.
0
'
L
T
53
.
8
5
R
I
M
47
.
3
I
E
I
N
N
O
R
T
H
(4
7
.
2
I
E
I
N
E
A
S
T
)
(4
7
.
1
5
I
E
O
U
T
W
E
S
T
)
1
PROJECT SITE
APN: 204-240-22
SEE DWG 551-3A FOR ONSITE IMPROVEMENTS
EX. SEWER C.O.
(51.8 RIM)
(~46.1 IE)
EX. SEWER MH
(55.84 RIM)
(43.6 IE IN WEST)
(43.5 IE OUT EAST)
ST
A
.
4
+
3
0
.
1
6
~
4
.
8
'
R
T
CO
N
N
E
C
T
T
O
E
X
I
S
T
I
N
G
SE
W
E
R
M
A
I
N
;
45
.
6
I
E
@
L
A
T
;
(4
4
.
9
I
E
@
M
A
I
N
)
ST
A
.
4
+
8
4
.
4
2
~
1
3
.
8
'
R
T
CO
N
N
E
C
T
T
O
N
E
W
6
"
P
V
C
WA
T
E
R
M
A
I
N
S
E
E
T
B
D
A
T
A
TA
B
L
E
T
H
I
S
S
H
E
E
T
;
S
E
E
PR
O
F
I
L
E
S
H
E
E
T
3
(~
4
8
.
9
T
P
)
ST
A
.
4
+
7
7
.
2
8
~
1
3
.
6
'
R
T
CO
N
N
E
C
T
T
O
N
E
W
6
"
P
V
C
WA
T
E
R
M
A
I
N
S
E
E
T
B
D
A
T
A
TA
B
L
E
T
H
I
S
S
H
E
E
T
;
S
E
E
PR
O
F
I
L
E
S
H
E
E
T
3
(~
4
8
.
6
T
P
)
ST
A
.
4
+
1
1
.
6
7
~
1
1
.
2
'
R
T
CO
N
N
E
C
T
T
O
E
X
I
S
T
I
N
G
6"
A
C
W
A
T
E
R
M
A
I
N
;
(~
4
6
.
7
5
T
P
)
1.1%
30
.
0
'
60
.
0
'
EX. OVERHEAD UTILITIES
TO BE REMOVED PER
SEPARATE SDGE WORK
ORDER
ST
A
.
4
+
1
1
.
6
6
~
2
7
.
6
6
'
L
T
1"
I
R
R
I
G
A
T
I
O
N
W
A
T
E
R
ME
T
E
R
;
~
4
7
.
5
T
P
ST
A
.
4
+
7
6
.
7
8
~
3
1
.
5
'
L
T
3"
D
O
M
E
S
T
I
C
W
A
T
E
R
ME
T
E
R
;
~
4
9
.
9
T
P
ST
A
.
4
+
3
3
.
6
6
~
2
0
.
0
'
L
T
CL
O
F
2
4
-
F
T
P
C
C
DR
I
V
E
W
A
Y
A
P
R
O
N
ST
A
.
4
+
9
4
.
9
0
~
2
0
.
0
'
L
T
54
.
2
8
T
C
;
5
3
.
7
8
F
L
ST
A
.
5
+
0
3
.
6
7
~
2
0
.
5
'
L
T
MA
T
C
H
T
O
E
X
I
S
T
I
N
G
(5
4
.
7
T
B
)
;
(
5
4
.
5
F
L
)
EXISTING COMMUNICATION
PEDESTAL TO REMAIN
ST
A
.
3
+
7
2
.
4
2
~
2
0
.
0
'
L
T
50
.
7
1
T
C
;
5
0
.
7
1
F
L
;
0
"
C
&
G
ST
A
.
3
+
7
0
.
4
2
~
2
5
.
5
'
L
T
50
.
8
F
S
1
2
3
ST
A
.
4
+
6
7
.
1
5
~
2
6
.
3
'
R
T
EX
.
F
I
R
E
H
Y
D
R
A
N
T
A
N
D
SE
R
V
I
C
E
T
O
R
E
M
A
I
N
ST
A
.
3
+
7
7
.
9
1
~
1
0
.
0
'
L
T
EX
.
G
A
S
S
E
R
V
I
C
E
T
O
BE
R
E
M
O
V
E
D
P
E
R
SE
P
A
R
A
T
E
S
D
G
E
WO
R
K
O
R
D
E
R
ST
A
.
4
+
4
3
.
2
3
~
1
2
.
3
'
R
T
EX
.
W
A
T
E
R
S
E
R
V
I
C
E
AN
D
M
E
T
E
R
T
O
B
E
RE
M
O
V
E
D
S
E
E
S
I
T
E
NO
T
E
2
T
H
I
S
S
H
E
E
T
EXISTING SEWER
LATERAL TO REMAIN
EX. AC SWALE TO BE REMOVED; AREA
TO BE GRADE TO DIRECT DRAINAGE
OVER NEW AC BERM OR EXISTING
DRIVEWAY
EX. AC DRIVEWAY TO
REMAIN
EX. AC BERM TO
REMAIN
EX. AC DRIVEWAY TO
REMAIN
EX. AC BERM TO
REMAIN
EX. POWER POLE TO
REMAIN
ST
A
.
4
+
5
6
.
5
6
~
2
2
.
5
'
L
T
15
-
F
T
M
A
R
I
N
A
S
T
R
A
W
B
E
R
R
Y
TR
E
E
W
E
L
L
B
M
P
P
E
R
D
W
G
5
5
1
-
3
L
EX. FENCE TO
REMAIN
EX. AC BERM TO
REMAIN
16
10
10
91114
14
12
1599
13
2
6
7 8
5
EX. PCC DRIVEWAY
APRON TO REMAIN
3
JUNIPER AVE STA. 4+33.66 =
PVT DR STA. 1+00.00
ROW
51.3 FS
(50.9 FS)
54.35 FS
2.
0
%
MA
X
2.
0
%
MA
X
2.
0
%
MA
X
9.
7
%
LOT 1
MAP 7961
LOT 1
MAP 7248 PARCEL 1
PM 1443
BLOCK R
LOT 2
SWLY 65.5'
EXC SELY 105'
MAP 1803
CL
EX. PCC DRIVEWAY
APRON TO REMAIN
EXISTING DRY UTILITY VAULT
TO REMAIN; ADJUST TO GRADE
4' X 4' WELD HOLE
17
1
3
2
ST
A
.
3
+
9
0
.
3
8
~
2
0
.
0
'
L
T
51
.
0
5
T
C
50
.
5
5
F
L
/
L
P
47
.
9
5
I
E
O
U
T
E
A
S
T
4.4%
ST
A
.
4
+
2
5
.
6
7
~
1
6
.
2
'
L
T
CO
N
N
E
C
T
T
O
G
A
S
MA
I
N
P
E
R
S
E
P
A
R
A
T
E
SD
G
E
W
O
R
K
O
R
D
E
R
51.0 FS 51.65 FS
51.5 FS
51.6 FS
52.3 FS
52.15 FS
51.75 RIM
46.3 IE
53.0 FS
53
52
53.6 FS
ST
A
.
3
+
7
3
.
4
2
~
2
0
.
0
'
L
T
51
.
1
8
T
C
;
5
0
.
6
8
F
L
Q100 = 5.25 CFS
1
1
REPLACE 6" AC WATER MAIN
WITH 6" PVC WATER MAIN
SEE NOTE THIS SHEET
DEEP ROOT TREE
BUBBLER PER SDRSD I-4
3.3%
ROW
5
151.3 FS
2.0%
PCC SIDEWALK WING
TRANSITION PER SDRSD G-14
51
52
54
54
2.
8
%
2.
6
%
2.
6
%
1.
9
%
2.
0
%
2.
5
%
1.
9
%
(51.47 FS)
(51.92
FS)
(52.18 FS)
(51.55 FS)
(0.5%)
51
LIMITS OF GRADING
FOR DRAINAGE
REPLACE AC BERM
FROM EDGE OF
ROW TO FACE OF
SIDEWALK
53
(52.42 FS)
LIMITS OF
TRANSTION (52.49 FS)
LIMITS OF
TRANSTION
EXISTING PCC
CURB TO REMAIN
(0.6%)
EXISTING AC BERM
TO REMAIN
51
5.5'
LIMITS OF AC PAVEMENT
TRANSITION
ST
A
.
3
+
7
5
.
1
1
~
2
8
.
9
'
L
T
IN
S
T
A
L
L
S
T
R
E
E
T
T
R
E
E
P
E
R
DW
G
5
5
1
-
3
L
ST
A
.
3
+
8
8
.
3
0
~
2
8
.
9
'
L
T
IN
S
T
A
L
L
S
T
R
E
E
T
T
R
E
E
P
E
R
DW
G
5
5
1
-
3
L
ST
A
.
4
+
9
2
.
0
3
~
2
8
.
9
'
L
T
IN
S
T
A
L
L
S
T
R
E
E
T
T
R
E
E
P
E
R
DW
G
5
5
1
-
3
L
STREET TREE MAINTENANCE NOTE:
1. THE HOA IS RESPONSIBLE FOR THE MAINTENANCE OF THESE TREES FOR ONE-YEAR
FROM THE CITY'S ACCEPTANCE OF THE IMPROVEMENTS.
2. ONCE THIS PERIOD HAS BEEN COMPLETED AND THE TREES AVER VERIFIED TO BE IN
GOOD HEALTH BY THE CITY'S PARKS MAINTENANCE REPRESENTATIVE, THE CITY WILL
ASSUME MAINTENANCE.
3. ALL PUBLIC RIGHT-OF-WAY PLANTINGS, EXCEPT STREET TREES, WILL BE MAINTAINED
BY THE HOA.
PROFILE VIEW - JUNIPER AVE CL
HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4'
(2.6%)
(0.9%)
3+
0
0
.
0
0
(5
1
.
5
8
F
S
)
3+
5
0
.
0
0
(5
1
.
3
0
F
S
)
4+
0
0
.
0
0
(5
1
.
6
1
F
S
)
4+
5
0
.
0
0
(5
2
.
5
3
F
S
)
5+
0
0
.
0
0
(5
4
.
4
5
F
S
)
5+
5
0
.
0
0
(5
5
.
6
2
F
S
)
6+
0
0
.
0
0
(5
5
.
1
9
F
S
)
4+00 4+50 5+00
50 CL
54 CL
46 CL
58 CL
42 CL 3+503+002+90 5+50 6+00
50 CL
54 CL
46 CL
58 CL
42 CL
(3.8%)
(2.4%)
(0.6%)(0.6%)4+
2
5
.
0
0
(5
1
.
9
2
F
S
)
3+
7
0
.
4
2
(5
1
.
3
5
F
S
)
EXISTING 6" VC SEWER
MAIN PER DWG 117-2
TOP OF EXISTING 6" AC
WATER MAIN PER DWG 170-6
EXISTING GRADE AT STREET
CENTERLINE
ST
A
.
4
+
3
0
.
1
6
CO
N
N
E
C
T
T
O
E
X
I
S
T
I
N
G
SE
W
E
R
M
A
I
N
;
45
.
6
I
E
@
L
A
T
;
(4
4
.
9
I
E
@
M
A
I
N
)
ST
A
.
4
+
8
4
.
4
2
CO
N
N
E
C
T
T
O
N
E
W
6
"
PV
C
W
A
T
E
R
M
A
I
N
;
(~
4
8
.
9
T
P
)
SE
E
P
R
O
F
I
L
E
S
H
E
E
T
3
ST
A
.
4
+
7
7
.
2
8
CO
N
N
E
C
T
T
O
N
E
W
6
"
PV
C
W
A
T
E
R
M
A
I
N
;
(~
4
8
.
6
T
P
)
SE
E
P
R
O
F
I
L
E
S
H
E
E
T
3
ST
A
.
2
+
8
9
.
0
8
EX
.
S
E
W
E
R
C
O
.
(5
1
.
8
R
I
M
)
;
(4
6
.
1
I
E
)
ST
A
.
5
+
8
3
.
4
0
EX
.
S
E
W
E
R
M
H
(5
5
.
8
5
R
I
M
)
;
(4
3
.
6
I
E
)
ST
A
.
4
+
1
1
.
6
7
CO
N
N
E
C
T
T
O
E
X
.
6
"
A
C
WA
T
E
R
W
A
T
E
R
M
A
I
N
;
(~
4
6
.
7
5
T
P
)
2
7
8
6
SOLID LINE REPRESENTS
TOP OF CURB
PROFILE VIEW - JUNIPER AVE TC LT
HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4'
50 TC
54 TC
50 TC
54 TC
4+00 4+50 5+003+70
(0.5%)
EXISTING 12" CMP STORM
DRAIN PER DWG 123-7
ST
A
.
4
+
2
5
.
6
5
~
1
6
.
2
3
'
L
T
EX
.
S
T
O
R
M
D
R
A
I
N
IN
L
E
T
T
O
B
E
R
E
M
O
V
E
D
ST
A
.
4
+
3
8
.
5
0
~
1
6
.
0
'
L
T
51
.
6
5
R
I
M
;
47
.
5
I
E
I
N
W
E
S
T
47
.
5
I
E
I
N
N
O
R
T
H
(4
7
.
4
5
I
E
O
U
T
E
A
S
T
)
14
1.0%
12" RCP STORM;
SEE SD DATA
TABLE THIS SHEET
ST
A
.
4
+
9
1
.
1
0
~
1
6
.
0
'
L
T
53
.
8
5
R
I
M
;
47
.
3
I
E
I
N
N
O
R
T
H
(4
7
.
2
I
E
I
N
W
E
S
T
)
(4
7
.
1
5
I
E
O
U
T
E
A
S
T
)
14
ST
A
.
3
+
9
0
.
3
8
~
2
0
.
0
'
L
T
51
.
5
5
T
C
/
L
P
47
.
9
5
I
E
O
U
T
E
A
S
T
13
3+
9
0
.
3
8
51
.
0
5
T
C
/
L
P
DASHED LINE REPRESENTS
EXISTING FLOWLINE
4+
5
0
.
0
0
52
.
3
2
T
C
DASH DOT LINE REPRESENTS
PROPOSED FLOWLINE
4+
0
0
.
0
0
51
.
1
0
T
C
PROPOSED 4" PVC DOM.
WATER SERVICE 49.78 TP
SEE PROFILE SHEET 3
PROPOSED 6" PVC DOM.
WATER SERVICE 49.95 TP
SEE PROFILE SHEET 3
PROPOSED 1" IRRIGATION
WATER SERVICE
47.95 IE OUT
47.5 IE IN
4+
7
5
.
0
0
53
.
4
0
T
C
(47.45 IE OUT)
(47.15 IE OUT)
(47.2 IE IN)
47.3 IE OUT
(0.5%)
1.0' MIN.
PVI STA: 3+95.00
PVI ELEV: 50.95
K: 9.81
LVC: 30.00
BV
C
S
:
3
+
8
0
.
0
0
BV
C
E
:
5
1
.
1
1
EV
C
S
:
4
+
1
0
.
0
0
EV
C
E
:
5
1
.
2
5
LOW PT. STA: 3+90.38
LOW PT ELEV: 51.05
PVI STA: 4+40.00
PVI ELEV: 51.85
K: 16.54
LVC: 40.00
BV
C
S
:
4
+
2
0
.
0
0
BV
C
E
:
5
1
.
4
5
EV
C
S
:
4
+
6
0
.
0
0
EV
C
E
:
5
2
.
7
3
4.4%
2.0%1.1%
ST
A
.
3
+
7
3
.
4
2
51
.
1
8
T
C
;
5
0
.
6
8
F
L
ST
A
.
4
+
9
4
.
9
0
54
.
2
8
T
C
;
53
.
7
8
F
L
ST
A
.
3
+
7
0
.
4
2
50
.
7
1
T
C
;
50
.
7
1
F
L
ST
A
.
4
+
3
3
.
6
6
~
2
0
.
0
'
L
T
CL
O
F
P
R
O
P
O
S
E
D
2
4
'
PC
C
D
R
I
V
E
W
A
Y
H&A
TC
•
_-
'
0
0
·O
r
'
,--
.
'
'
'
A-" p .A
0
0
0
0
0
0
□
-
I
+
I t
+
-, ' l
I
'
I -'
l
I
r
-,
I-,
I
I
I ----i-------
-,
_l
'-,--
l
t
'
T
_I
+
'
' I
--,------_,
-
' I
--,....--,
-,
-----, -,-
.-,------
0
0
0
0
0
0
0
'
'
r-,
-;--
'
T
' -
' -
,---
-
' '
"'--
' j_
_/ _ _l__'-===t=--.
·-
-,"
'
-
r
_j
'
' '
0
0
0
T
'
I ' '
.---r-,--
_L
,--
J '
,--------,-'
'
-
-
-,
' I
'
'
'-----r 1\\.-==f=-
C
'
' ,--
t t t t t
--' -,
-_j
I ¢
'
I -J_ ! I
T ~~_[~ 1-l~ • [ T~ '
_j
_ I L
'
t
t
_J
-'' ,J
/ I _,_ ,-I
~l-1/"-/--z--==j ·,_ -• , ==;=== ,=_lr===~==·~-~'==-='~~~== ' -
,--,--J
'
-, +-----,-r
j
l.. '
' ' ' ' C ,---
I ' '
. I ' . --------,-_J
\'
,----
I I ' I I ' I '
-------r-;---\ -
-,---,
T '
L !i'. \
I ...1
,----
_t T _[ l ---l l
,--'
--,, ' -' '
cl
C
,--,--
' '
-'
_I
.L I
J L I -
-,
,--
'
' ' -----
'
' ' '
ANCHOR BLOCK~: ~~M~ A!~;ME (CF! BEND I FITTI . SERVICE 36.5
4" DOMESTIC 90DEGBENO
900EGBENO 6' FIRE HYDRANT
I
78.5
_l
-, I
'
J I . .
1 OCK DATA TABLE THRUST BL REA (SF) APPROX SIZE BEND/ FITTING ~BEARING A 2' X2' SERVICE
4" DOMESTIC
6 .. FIRE HYDRANT
I
r--'
90 DEG BENO 4,0 3· X 2.75'
90 DEG BENO 8.25 '
' -, ' r-
. ,--
-
'
'
l
I
-,
,-, '
' -,
' -
'
I I
' '
--------;-----,-I 1--T ' ----,--I ,---I I ' ' ---
L '
' r-
_j
L
--
-' ' -
--I----l
' ' I
-' ' ' ' '
I )
I l
A=1--::,...._ ---:-r :::-:n.,,------,., • V
□
F""
L.Ll
I
DAlE INITIAL
: ENGINEER OF WORK REVISION DESCRIPTION
-,
. . .
'
' ..--r--
-
,-------, '
' ,-
-
I
I
1
--+-------r-,-----T, -,--'
-
-
C
/
f_ J
/
rr
P L S~
~l)ffMN •1
P.E.--EXP.
PLSAENGINEERING.COM
Y OF CARLSBAD I SHEET I CI~NGINEERING DEPARlMENT
IMPROVEMENT PLANS FOR:
I
-
'
I SHEETS I
PUD 2023-0007
CDP 2023-0058
APPR0VED:TIM0THY 0. CARROLL
DAlE INITIAL
DlHER APPROVAL
DA 1E INITIAL
a1Y APPROVAL
PRINCl'AL ENGINEER
RVWD BY:--,' I
CHKD BY: -
RCE 553111 EXP .12/31/26 DAlE
PROJECT NO. I DRAWING NO.
-
Docusign Envelope ID: EC7F77F8-CD7A-4270-8873-F956CDAC434F
4/30/2026
J:\ACTIVE JOBS\4052 RINCON-270 JUNIPER\CIVIL\DRAWING\IMPROVEMENT PLANS
SA
V
E
D
A
T
E
:
20
2
6
-
4
-
8
-
P
L
O
T
D
A
T
E
:
2
0
2
6
-
4
-
8
9
:
0
2
A
M
-
F
I
L
E
N
A
M
E
:
J
:
\
A
C
T
I
V
E
J
O
B
S
\
4
0
5
2
R
I
N
C
O
N
-
2
7
0
J
U
N
I
P
E
R
\
C
I
V
I
L
\
D
R
A
W
I
N
G
\
I
M
P
R
O
V
E
M
E
N
T
P
L
A
N
S
\
4
0
5
2
-
C
V
-
I
P
-
0
3
-
S
E
C
T
S
.
d
w
g
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
19
1
1
S
A
N
D
I
E
G
O
A
V
E
N
U
E
,
S
A
N
D
I
E
G
O
C
A
9
2
1
1
0
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
"AS BUILT"
DATE
INSPECTOR DATE
REVIEWED BY:
IMP 2025-0001
551-3
JUNIPER COAST HOMES
270 JUNIPER AVENUE
CT 2023-0005
PLSA 4052
43
SECTIONS & DETAILS
TYPICAL DETAIL - AC PAVEMENT SAWCUT
NOT TO SCALE
TYPICAL SECTION - JUNIPER AVENUE
NOT TO SCALE
JUNIPER AVE STA. 3+80
NOT TO SCALE
JUNIPER AVE STA. 3+90.77
NOT TO SCALE
JUNIPER AVE STA. 4+80
NOT TO SCALE
JUNIPER AVE STA. 4+30
NOT TO SCALE
4" WATER SERVICE NOTE:
4" WATER SERVICE BETWEEN REDUCER AT GATE
VALVE NEAR TEE TO ABOVE GROUND 90-DEGREE
ELBOW BEND AT METER; 3" AFTER BEND.
MJ RESTRAINT NOTE:
MECHANICAL JOINT RESTRAINT ON 4" DOMESTIC WATER
SERVICE FROM CONNECTION AT MAIN TO 3" METER;
MECHANICAL JOINT RESTRAINT ON 6" FIRE SERVICE
FROM CONNECTION AT MAIN TO 6" BACKFLOW
GU
T
T
E
R
L
I
N
E
SA
W
C
U
T
L
I
N
E
**18.5' MIN.
8.0'
6" PCC CURB & GUTTER
PER SDRSD G-2
*STRUCTURAL SECTION MIN. 4" AC
OVER 6" CLASS II AB OVER NATIVE
SUBGRADE COMPACTED TO 95%
REL. COMP.
COLD PLANE AND OVERLAY (2"
MIN. DEPTH) TO PROVIDE SMOOTH
TRANSITION
EXISTING AC PAVEMENT
*TO BE VERIFIED BY PROJECT GEOTECH
ENGINEER BASED ON FIELD TESTED
R-VAULE
**18.5' MIN. COLD PLANE AND OVERLAY AC
PAVEMENT TO CENTERLINE; PROVIDED
SMOOTH TRANSITION FROM SAWCUT SEE
PLAN FOR ACTUAL DIMENSIONS
6"
PROP. 4" PCC SIDEWALK
PER SDRSD G-7
PROP. 6" PCC CURB
AND GUTTER PER
SDRSD G-2
SOUTH
ROW
PROPOSED AC PAVEMENT
SAWCUT PER DETAIL THIS SHEET
CLPL
10.0'
4.0'
0.5'
10.0'
4.5'5.5'
20.0'20.0'
EX. 6" VC SEWER MAIN
PER DWG 117-2
EX. 6" AC WATER MAIN
PER DWG 170-6
EX. 12" CMP STORM
DRAIN PER DWG 123-7
60.0'
1.5%(1-2%)
EX. 6" PCC CURB
AND GUTTER
EX. 4" PCC
SIDEWALK
NORTH
ROW
5.5'
*4" AC OVER 6"
CLASS II AB
*TO BE VERIFIED BY PROJECT
GEOTECH ENGINEER BASED ON
FIELD TESTED R-VAULE
9.5'10.5'
PROFILE VIEW - PVT STORM DRAIN LINE 3
HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4'
1.2%
1+00 1+40
47 EL
51 EL
55 EL
47 EL
51 EL
55 EL
PL /
ROW
PUBLIC PVT14
PROPOSED FINISHED SURFACE
12" RCP STORM DRAIN SEE SD
DATA TABLE SHEET 2
18" X 18" BROOKS BOX PER
DWG 550-3A
JU
N
I
P
E
R
A
V
E
ST
A
.
4
+
3
8
.
5
0
~
1
6
.
0
'
L
T
51
.
6
5
R
I
M
;
47
.
5
I
E
I
N
W
E
S
T
47
.
5
I
E
I
N
N
O
R
T
H
(4
7
.
4
5
I
E
O
U
T
E
A
S
T
)
47.45 IE OUT
47.5 IE IN
47.7 IE OUT
Q100=0.08 CFS
V=1.67 FPS
PL /
ROW
1+00 1+40
PROFILE VIEW - PVT STORM DRAIN LINE 2
HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4'
3.2%
47 EL
51 EL
55 EL
47 EL
51 EL
55 EL
PUBLIC PVT
14
12" X 12" BROOKS BOX
PER DWG 550-3A
BMP PLANTER PER
DWG 550-3A
18" X 18" BROOKS
BOX PER DWG
550-3A
12" RCP STORM DRAIN SEE
SD DATA TABLE SHEET 2
12" PVC STORM DRAIN
PER DWG 550-3A
1.1%(47.15 IE OUT)
47.3 IE IN
47.8 IE OUT
47.9 IE IN
ST
A
.
4
+
9
1
.
1
0
~
1
6
.
0
'
L
T
53
.
8
5
R
I
M
;
47
.
3
I
E
I
N
N
O
R
T
H
(4
7
.
2
I
E
I
N
W
E
S
T
)
(4
7
.
1
5
I
E
O
U
T
E
A
S
T
)
PROPOSED FINISHED
SURFACE
Q100=0.06 CFS
V=1.64 FPS
CL
LIMITS OF COLD
PLANE TRANSITION
(51.50 FS/EOP)
51.10 TC
50.60 FL
PL /
ROW
30.0'
10.5'9.5'10.0'
2.5%
2.0%
MAX.
AC PAVEMENT SAWCUT
PER DETAIL THIS
SHEET
DASHED LINE REPRESENTS
APPROX. EXISTING GRADE
(50.6 FL/EOP)
12.4'
GRIND AND OVERLAY
2.5%
CL
30.0'
10.5'9.5'10.0'
PL /
ROW
AC PAVEMENT SAWCUT
PER DETAIL THIS
SHEET
51.03 TC
50.53 FL/LP
2.0%
MAX.
(50.45 FL/EOP)
LIMITS OF COLD
PLANE
TRANSITION
(51.47 FS/EOP)
2.6%
DASHED LINE REPRESENTS
APPROX. EXISTING GRADE
GRIND AND OVERLAY
12.3'
PROPOSED D-2
CURB INLET
2.6%
CL
LIMIT OF COLD
PLANE TRANSITION
(53.62 FS)
53.62 TC
53.12 FL
30.0'
10.5'9.5'10.0'
2.0%
MAX.2.7%
AC PAVEMENT SAWCUT
PER DETAIL THIS
SHEET
DASHED LINE REPRESENTS
APPROX. EXISTING GRADE
PL /
ROW
(53.0 FL/EOP)
CL
51.67 TC
51.17 FL
30.0'
10.5'9.5'10.0'
2.0%
MAX.9.7%2.1%
AC PAVEMENT SAWCUT
PER DETAIL THIS
SHEET
DASHED LINE REPRESENTS
APPROX. EXISTING GRADE
PL /
ROW
(50.6 FL)GRIND AND OVERLAY
19.5'
LIMITS OF COLD
PLANE TRANSITION
(52.08 FS/EOP)
EXISTING C&G
2.1%
47 EL
51 EL
55 EL
47 EL
51 EL
55 EL
PROFILE VIEW - FIRE SERVICE CROSSING
HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4'
CL
1+00 1+50
PL
8
EXISTING 12" CMP SD PER
DWG 123-7; (47.23 IE)
PROPOSED 6" PVC FIRE
SERVICE
ST
A
.
1
+
0
5
.
6
9
IN
S
T
A
L
L
1
1
.
2
5
°
E
L
B
O
W
;
48
.
9
T
P
M
J
R
E
S
T
R
A
I
N
T
S
E
E
NO
T
E
T
H
I
S
S
H
E
E
T
ST
A
.
1
+
1
2
.
7
7
IN
S
T
A
L
L
1
1
.
2
5
°
E
L
B
O
W
;
50
.
3
T
P
M
J
R
E
S
T
R
A
I
N
T
S
E
E
NO
T
E
T
H
I
S
S
H
E
E
T
EXISTING 6" VC SEWER MAIN
PER DWG 117-2; (44.45 IE)
DASHED LINE REPRESENTS
APPROX. EXISTING GRADE
SOLID LINE REPRESENTS
APPROX. PROPOSE GRADE
ST
A
.
1
+
0
0
.
0
0
CO
N
N
E
C
T
T
O
W
A
T
E
R
M
A
I
N
SE
E
N
O
T
E
A
C
W
A
T
E
R
M
A
I
N
RE
P
L
A
C
E
M
E
N
T
N
O
T
E
SH
E
E
T
2
;
(
~
4
8
.
9
T
P
)
ST
A
.
1
+
2
2
.
7
7
IN
S
T
A
L
L
H
I
G
H
D
E
F
L
E
C
T
I
O
N
CO
U
P
L
I
N
G
;
5
0
.
3
T
P
M
J
RE
S
T
R
A
I
N
T
S
E
E
N
O
T
E
T
H
I
S
SH
E
E
T
ST
A
.
1
+
3
2
.
7
7
IN
S
T
A
L
L
H
I
G
H
D
E
F
L
E
C
T
I
O
N
CO
U
P
L
I
N
G
;
4
9
.
9
5
T
P
M
J
RE
S
T
R
A
I
N
T
S
E
E
N
O
T
E
T
H
I
S
SH
E
E
T
3.0'
(MIN.)
EX. GAS MAIN; DEPTH
TO BE VERIFIED IN
THE FIELD
CL
47 EL
51 EL
55 EL
47 EL
51 EL
55 EL
PROFILE VIEW - 4" DOMESTIC WATER CROSSING
HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4'
1+00 1+50
PL
7
ST
A
.
1
+
0
0
.
0
0
CO
N
N
E
C
T
T
O
W
A
T
E
R
M
A
I
N
SE
E
N
O
T
E
A
C
W
A
T
E
R
M
A
I
N
RE
P
L
A
C
E
M
E
N
T
N
O
T
E
SH
E
E
T
2
;
(
~
4
8
.
8
T
P
)
ST
A
.
1
+
0
5
.
2
3
IN
S
T
A
L
L
1
1
.
2
5
°
E
L
B
O
W
;
48
.
7
2
T
P
M
J
R
E
S
T
R
A
I
N
T
S
E
E
NO
T
E
T
H
I
S
S
H
E
E
T
ST
A
.
1
+
2
2
.
9
3
IN
S
T
A
L
L
H
I
G
H
D
E
F
L
E
C
T
I
O
N
CO
U
P
L
I
N
G
;
4
9
.
7
8
T
P
M
J
RE
S
T
R
A
I
N
T
S
E
E
N
O
T
E
T
H
I
S
SH
E
E
T
EXISTING 12" CMP SD PER
DWG 123-7; (47.25 IE)EXISTING 6" VC SEWER MAIN
PER DWG 117-2; (44.50 IE)
PROPOSED 4" PVC
DOMESTIC WATER SERVICE;
SEE NOTE THIS SHEET
SOLID LINE REPRESENTS
APPROX. PROPOSE GRADE
DASHED LINE REPRESENTS
APPROX. EXISTING GRADE
EX. GAS MAIN; DEPTH
TO BE VERIFIED IN
THE FIELD
ST
A
.
1
+
1
2
.
5
5
IN
S
T
A
L
L
1
1
.
2
5
°
E
L
B
O
W
;
50
.
1
7
T
P
M
J
R
E
S
T
R
A
I
N
T
S
E
E
NO
T
E
T
H
I
S
S
H
E
E
T
ST
A
.
1
+
2
2
.
5
5
IN
S
T
A
L
L
H
I
G
H
D
E
F
L
E
C
T
I
O
N
CO
U
P
L
I
N
G
;
5
0
.
1
7
T
P
M
J
RE
S
T
R
A
I
N
T
S
E
E
N
O
T
E
T
H
I
S
S
H
E
E
T
3.0'
(MIN.)
H&A
TC
()
"' ~ t
I / > -I II I \ -- --\
\
,... -/-1-~ u --
\
■f----+----+----+----+----+--++----+----+--I
'
/
,v - -V \ '
I\ -4----:: 'V , I
I
I
I I I I
I
I I
------
~ ' -!-_ . ...__ -
I I
I
I~ -' ' ' " I \
I \
I \
"'I!
I
' ' ' ' '
I
I I
·--
I =--
I I I
I I
I _/I I I I I
J
'I 1 -I
I I I\.
I '
~ lJ
I
. .
'
'
NOTES:
GRIPPER GASKET LLC
MAXADAPTER
COUPLING
GRIPPER GASKET LLC
MAXADAPTER
COUPLING
I 3' PVC SEWER
,....._ __ _._,I PIPE SPOOL
I
)~ 45· PVC v wYc
I
I
I f-----~ Ii i
_/
~l
I
3' PVC SEWER
PIPE SPOOL
EXISTING PVC
OR VCP
SEWER MAIN
00_5 -n<1' MAXI'"'" PLAN
FROM VERTICAL '\r------i
45• PV< 1~
WYE~1 ," / 45' ,,. I ~-~
~ _.,, EXISTING PVC
---OR VCP
SEWER MAIN
ELEVATION
TYPE C
CUT-IN WYE CONNECTION FOR
EXISTING VCP OR PVC PIPE
1. REFER TO SECTION 15063 FOR SEWER PIPE AND FITTINGS.
2. CONNECTION TO BE MADE 22.5-DEG MAX. FROM VERTICAL TO 45-DEG (AS SHOWN) FROM HORIZONTAL
3. NO MORE THAN ONE CUT IN WYE WILL BE ALLOWED FOR EACH LENGTH OF
EXISTING VCP SEWER MAIN.
4. FOR SEWER LATERAL INSTALLATION SEE S-7 AND S-8.
5. FOR TRENCH BACKFILL SEE S-5.
6. MATERIALS SHALL BE SELECTED FROM THE APPROVED MATERIALS LIST.
7. 6-IN ON 6-IN ALLOWED FOR 270 JUNIPER AVENUE
MODIFIED STD DWG S-10 AS APPROVED BY UTILITIES DEPARTMENT
FOR 270 JUNIPER AVENUE 6-INCH SEWER CONNECTION. MARKUS MOHRLE, UTILITIES, SR. ENGINEER
REV. APPROVED DATE CITY OF CARLSBAD
4" AND 6" SEWER
SADDLE WYE CONNECTION
CITY ENGINEER
MODIFIED DWG. NO.
3/19/26
!5;'38;1@1
DATE
S-10
--
-\
-
\
-\
I
I
-=-~
_j
... ;--\ \
/
--I
PLSA
,l)ff~
PLSAENGINEERING.COM
\ --
\
P.E. __ _ EXP-----
---------------+---+----+---+----I I SHEET I CITY OF CARLSBAD I SHEETS I ENGINEERING DEPARlMENT :==::...::::=========::....:::::=::::::
DAlE INITIAL
ENGINEER OF WORK REVISION DESCRIPTION
IMPROVEMENT PLANS FOR:
PRINCl'AL ENGINEER
PUD 2023-0007
CDP 2023-0058
APPR0VED:TIM0THY 0. CARROLL
RCE 553111 EXP .12/31/26 DAlE
DAlE INITIAL DAlE INITIAL RVWD BY: ---1 I PROJECT NO. I DRAWING NO.
DlHER APPROVAL aTY APPROVAL CHKD BY: . .
Docusign Envelope ID: EC7F77F8-CD7A-4270-8873-F956CDAC434F
4/30/2026
J:\ACTIVE JOBS\4052 RINCON-270 JUNIPER\CIVIL\DRAWING\IMPROVEMENT PLANS
SA
V
E
D
A
T
E
:
2
0
2
6
-
4
-
8
-
P
L
O
T
D
A
T
E
:
2
0
2
6
-
4
-
8
9
:
0
2
A
M
-
F
I
L
E
N
A
M
E
:
J
:
\
A
C
T
I
V
E
J
O
B
S
\
4
0
5
2
R
I
N
C
O
N
-
2
7
0
J
U
N
I
P
E
R
\
C
I
V
I
L
\
D
R
A
W
I
N
G
\
I
M
P
R
O
V
E
M
E
N
T
P
L
A
N
S
\
4
0
5
2
-
C
V
-
I
P
-
0
3
-
S
E
C
T
S
.
d
w
g
PA
S
C
O
,
L
A
R
E
T
,
S
U
I
T
E
R
&
A
S
S
O
C
I
A
T
E
S
19
1
1
S
A
N
D
I
E
G
O
A
V
E
N
U
E
,
S
A
N
D
I
E
G
O
C
A
9
2
1
1
0
PH
:
(
8
5
8
)
2
5
9
-
8
2
1
2
F
A
X
:
(
8
5
8
)
2
5
9
-
4
8
1
2
"AS BUILT"
DATE
INSPECTOR DATE
REVIEWED BY:
IMP 2025-0001
551-3
JUNIPER COAST HOMES
270 JUNIPER AVENUE
CT 2023-0005
PLSA 4052
44
SECTIONS & DETAILS
SECTION C-C CURB CUT @ TREE WELL SDC GS DS GS 5.01
NOT TO SCALE
PLAN VIEW - CURB CUT @ TREE
WELL SDC GS DS GS-5.01
NOT TO SCALE
PLAN VIEW - CURB CUT @ TREE WELL
NOT TO SCALE
SECTION D-D CURB CUT @ TREE WELL SDC GS DS GS 5.01
NOT TO SCALE
NOT TO SCALE
SECTION B-B TREE WELL W/ GRATE
MODIFIED SDC GS 1.02
NOT TO SCALE
SECTION A-A TREE WELL W/ GRATE MODIFIED
SDC GS 1.02
TREE WELL NOTE:
TREE WELL BMP TO BE PRIVATELY
MAINTAINED BY HOA
NOT TO SCALE
SECTION E-E TREE WELL MODIFIED
SDC GS 1.02
9" x 30" x 12" DEEP TYPE 1
SPLASH PAD PER SDC DS
GS-5.06 (NO. 2 COARSE
AGGREGATE ROCK)
R=6"
(TYP.)
6" PCC C&G PER
SDRSD G-02GUTTER LIP
2
.
5
'
1
.
0
'
1
.
0
'
D D
C
C
18" CURB CUT OPENING
CENTERED AT TREE WELL
LOCATION AS SHOWN ON SHEET 4
GUTTER LIP
4
.
5
'
G
U
T
T
E
R
D
E
P
R
E
S
S
I
O
N
6" PCC C&G PER
SDRSD G-02
LIMITS OF 9" X
30" TREE GRATE
SUPPORT
TOP OF 6"
PCC C&G
TOP OF 6"
PCC C&G
4.5'
FLOWLINE
(PER PLAN)
FLOWLINE
(PER PLAN)1" GUTTER
DEPRESSION @
TREE WELL1" VERTICAL GUTTER
TRANSITION OVER 1'
HORIZONTAL
1.5' CURB CUT
OPENING 1.0' 1.0'
7"
1"
2.5'
6" PCC CURB &
GUTTER
A A
B
B
18" WIDE CURB CUT
CENTERED ON TREE
WELL (SEE DETAIL D-D)
SPLASH PAD
PER GS-5.06
15' MARINA STRAWBERRY
TREE DIAMETER CANOPY
STREET TREE WITH 353
CF MIN STRUCTURAL SOIL
LIMITS OF 30 MIL PLASTIC
IMPERMEABLE LINER ALONG
SIDES OF STRUCTURAL SOIL
6" THICK, 12" DEEPENED
EDGE SIDEWALK TREATMENT,
SEE SECTION B-B BELOW
CONSTRUCT CONTIGUOUS
PCC SIDEWALK
4.0' CLEAR MIN
LIMITS OF STRUCTURAL SOIL
BELOW (4' DEEP X 9.5' X 11.4')
10.0'
11
.
4
'
PL / ROW
E E
6" PCC CURB &
GUTTER
DEEP ROOT TREE BUBBLER
PER SDRSD DWG I-4
6" PCC C&G PER
SDRSD G-2
STREET FLOW
COMPACTED
SUBGRADE
CURB CUT PER
DETAIL THIS
SHEET
30 MIL PLASTIC
IMPERMEABLE LINER
AND ROOT BARRIER
SPLASH PAD
PER GS-5.06
12"
12"
2"
UNCOMPACTED SUBGRADE
PL /
ROW
PCC SIDEWALK
PER SDRSD G-7
8.75' LIMITS OF STRUCTURAL SOIL
4" X 8" SMOOTH DOWELS @
18" OC, GREASED ON ONE
END
9" X 30" TREE
GRATE SUPPORT
30 MIL PLASTIC
IMPERMEABLE LINER
ROOT BARRIER
PER SDRSD L-6
1:1 CUT
COMPACTED SOIL
SUBGRADE
30 MIL PLASTIC
IMPERMEABLE
LINER
48" DEEP STRUCTURAL SOIL;
STRUCTURAL PER A-1
STRUCTURAL SOIL OR
APPROVED EQUAL
6" SAND FILTER
LAYER
ROOT BARRIER
PER SDRSD L-6
STREET FLOW
COMPACTED
SUBGRADE
6" PCC CURB AND
GUTTER PER
SDRSD G-2
4" X 8" SMOOTH DOWELS @
18" OC, GREASED ON ONE
END, TYP. ALL SIDES PER
SDC GS DS GS-1.00
3" MIN MULCH
LAYER
4" OPENING FOR
DRAINAGE
4"#4 @ 18" O.C. BOTH
WAYS PER SDC GS
DS GS 1-.00
9" X 30" TREE
GRATE SUPPORT
3"
9"
STREET FLOW
CURB CUT PER DETAIL
THIS SHEET
30 MIL PLASTIC
IMPERMEABLE
LINER
48" DEEP STRUCTURAL SOIL;
STRUCTURAL PER A-1
STRUCTURAL SOIL OR
APPROVED EQUALDEEP ROOT TREE
BUBBLER PER
SDRSD DWG I-4
6" SAND FILTER
LAYER
ROOT BARRIER
PER SDRSD L-6
UNCOMPACTED SUBGRADE
9"
PCC SIDEWALK
PER SDRSD G-7
PL /
ROW
SPLASH PAD PER SDC
GS DS GS-5.06 TYPE 1
30 MIL PLASTIC
IMPERMEABLE LINER
ROOT BARRIER
PER SDRSD L-6
4' X 8' COHO TREE GATE FRAME BY URBAN
ACCESSORIES WITH COATED IRON AND
MATT BLACK FINISH; INSTALL GRATE PER
MANUFACTURER'S SPECIFICATIONS
COMPACTED
SUBGRADE
1:1 CUT
6" PCC C&G PER
SDRSD G-2
4.0' TREE GRATE COVER
8.75' LIMITS OF STRUCTURAL SOIL
ROOT
BALL
4' X 8' COHO TREE GATE FRAME WITH
COATED IRON IN MATT BLACK FINISH BY
URBAN ACCESSORIES; INSTALL GRATE PER
MANUFACTER'S SPECIFICATIONS
3" MIN MULCH
LAYER
9"
48" DEEP STRUCTURAL SOIL;
STRUCTURAL PER A-1
STRUCTURAL SOIL OR
APPROVED EQUAL
UNCOMPACTED SUBGRADE DEEP ROOT TREE BUBBLER
PER SDRSD DWG I-4
#4 @ 18" O.C. BOTH
WAYS PER SDC GS
DS GS 1-.009"
30"
3"
6" SAND FILTER
LAYER
30 MIL PLASTIC
IMPERMEABLE LINER
ROOT BARRIER
PER SDRSD L-6
9" X 30" TREE GRATE
SUPPORT; COMPACT SOIL
UNDER GRATE SUPPORT
30 MIL PLASTIC
IMPERMEABLE LINER
ROOT BARRIER
PER SDRSD L-6
INSTALL 30 MIL PLASTIC IMPERMEABLE
LINER WHERE CONCRETE IS POURED
OVER ENGINEERED SOIL (TYP.)
8.0' TREE GRATE COVER
9.0'
12.2' LIMITS OF STRUCTURAL SOIL
9"
H&A
TC
L
_____ l_
~•·:•/ .,/.J,.
/ I·
:; \ / 1 •
I
I
I v-
r----....,_______,..I _l_ r---1 I ---r-----'-1 -
_L __
/1'\
DA1E INITIAL
ENGINEER OF WORK
\'~Of ESS / a¼
~ <,.,~ G L-4/f,, '( P L S A /J' -A..'-<l'o ~ "' ... '1-i:' "' --2' "' No. 80Z356 ,,, ,~r,~~ P.E. EXP. 'ti w ~ ~ -
C/V\\. ~/,~ PLSAENGINEERING.COM .. JJF CALI~
I SHEET I I SHEETS I CITY OF CARLSBAD
ENGINEERING DEPARlMENT
IMPROVEMENT PLANS FOR:
PUD 2023-0007
CDP 2023-0058
APPROVED:TIMOTHY 0. CARROLL
PRINCl'AL ENGINEER RCE S53111 EXP.12/31/28 DA1E
I PROJECT NO. I DRAWING NO. DA1E INITIAL DA1E INITIAL RVWD BY:
REVISION DESCRIPTION DlHER APPROVAL ClY APPROVAL CHKD BY:
Docusign Envelope ID: EC7F77F8-CD7A-4270-8873-F956CDAC434F
4/30/2026