Loading...
HomeMy WebLinkAboutDWG 552-6; CT 2024-0004; JEFFERSON STREET HOMES; 01-04SITE JE F F E R S O N S T BUENA PL BUENA VISTA WAY KNOWLES AVE DA V I S A V E LAGUNA DR KR E M E Y E R CI R BUE N A VIS T A C I R MA D I S O N S T HOM E A V E I-5 F R E E W A Y LAS FLORES DR J:\ACTIVE JOBS\4138 RINCON JEFFERSON\CIVIL\DRAWING\IMPROVEMENT PLANS SA V E D A T E : 20 2 6 - 4 - 8 - P L O T D A T E : 2 0 2 6 - 4 - 9 1 0 : 1 5 A M - F I L E N A M E : J : \ A C T I V E J O B S \ 4 1 3 8 R I N C O N J E F F E R S O N \ C I V I L \ D R A W I N G \ I M P R O V E M E N T P L A N S \ 4 1 3 8 - C V - I P - 0 1 - T I T L E . d w g PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 "AS BUILT" DATE INSPECTOR DATE REVIEWED BY: 41 PLSA 4138 BAK CT 2024-0004 IMP 2025-0013 552-6 JEFFERSON STREET HOMES PUD 2024-0004 CDP 2024-0021 2002 PER ROS 17271 82.22'NGVD 29DATUM:ELEVATION: RECORDED: CADT DISK LOCATION: DESCRIPTION: 5315 AVENIDA ENCINAS CARLSBAD CA, 92008 (888) 357-3553 PHONE NO.: ADDRESS: NAME: PHONE NO.: ADDRESS: NAME:TOM ST. CLAIR FOR: 2502 & 2518 JEFFERSON LLC 5315 AVENIDA ENCINAS CARLSBAD CA, 92008 (888) 357-3553 N.T.S. 1 TITLE SHEET 2 BUENA VISTA WAY AVENUE IMPROVEMENT PLAN 3 JEFFERSON STREET IMPROVEMENT PLAN 4 DETAILS EG = EXISTING GRADE FS = FINISHED SURFACE FG = FINISHED GRADE FL = FLOWLINE FF = FINISHED FLOOR GF = GARAGE FACE IE = INVERT ELEVATION LA = LANDSCAPE AREA TB = TOP OF BERM TC = TOP OF CURB TG = TOP OF GRATE ELEVATION TP = TOP OF PIPE RJ = RESTRAINED JOINT RIM = TOP OF RIM ELEVATION EXISTING GRADE FYSB = FRONT YARD SETBACK RYSB = REAR YARD SETBACK SYSB = SIDE YARD SETBACK ABBREVIATION: SDRSD - SAN DIEGO REGIONAL STANDARD DRAWING CMWD - CARLSBAD MUNICIPAL WATER DISTRICT * NOTE: MODIFIED PER CITY OF CARLSBAD STANDARD **SECTION TO BE DETERMINED BY GEOTECH ENGINEER BASED ON R-VALUE TEST RESULTS THE IMPROVEMENT WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER.1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING IMPROVEMENTS SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER- OF-WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE MUST BE FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRENCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HAVE A RATING OF "A-" OR BETTER AND A SIZE CATEGORY OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RATING GUIDE. 5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER APPROPRIATE AGENCIES. 6. REVISION OF THESE PLANS MAY BE REQUIRED IF THE PROPOSED IMPROVEMENTS ARE NOT CONSTRUCTED PRIOR TO THE DEADLINE DATE OF THE IMPROVEMENT AGREEMENT. 7. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND TITLE SHEET. 8. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 9. THE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 10. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 11. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF COMPLETION OF FIELD TESTS. THE WRITTEN FIELD COMPACTION REPORT(S) SHALL BE IMMEDIATELY SUBMITTED TO THE CITY ENGINEERING INSPECTOR UPON COMPLETION OF THE FIELD TESTS. 12. A PRECONSTRUCTION MEETING SHALL BE HELD PRIOR TO THE BEGINNING OF WORK AND SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK. THE CONTRACTOR SHALL SCHEDULE THE MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 AT LEAST FIVE (5) WORKING DAYS PRIOR TO STARTING CONSTRUCTION. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. 13. ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCTION MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE WORK DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 14. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 15. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPE OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VARIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 16. NO BLASTING SHALL BE COMMENCED WITHOUT A CITY ENGINEER APPROVED BLASTING PROGRAM AND BLASTING PERMIT. 17. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK ZONE DURING CONSTRUCTION, OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 18. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 A.M. AND 6:00 P.M. EACH DAY, MONDAY THRU FRIDAY AND NO EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 19. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY INSPECTOR FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTE OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 20. IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 21. THE EXISTENCE AND LOCATION OF UTILITY STRUCTURES AND FACILITIES SHOWN ON THE CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. ATTENTION IS CALLED TO THE POSSIBLE EXISTENCE OF OTHER UTILITY FACILITIES OR STRUCTURES NOT SHOWN OR IN A LOCATION DIFFERENT FROM THAT SHOWN ON THE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON THE PLANS AND ANY OTHER EXISTING FACILITIES OR STRUCTURES NOT SHOWN. 22. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES ( ABOVEGROUND AND UNDERGROUND ) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF THE CONSTRUCTION TO PERMIT THE REVISIONS OF THE CONSTRUCTION PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. 23. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST TWO FULL WORKING DAYS PRIOR TO STARTING CONSTRUCTION NEAR THEIR FACILITIES AND SHALL COORDINATE WORK WITH A COMPANY REPRESENTATIVE. 24. IN ACCORDANCE THE CITY STORM WATER STANDARDS ALL STORM DRAIN INLETS CONSTRUCTED BY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTE DISCHARGE DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SATISFACTION OF THE CITY ENGINEER. UNDERGROUND SERVICE ALERT (800)422-4133 SDG&E (800)411-7343 AT&T (800)892-0123 TIME WARNER CABLE (760)438-7741 COX COMMUNICATIONS (619)262-1122 CITY OF CARLSBAD(STREETS AND STORM DRAIN) (760)434-2980 *CITY OF CARLSBAD(SEWER,WATER & RECLAIMED WATER)(760)438-2722 *SAN DIEGUITO WATER DISTRICT (760)633-2650 *LEUCADIA WASTEWATER DISTRICT (760)753-0155 *VALLECITOS WATER DISTRICT (760)744-0460 *OLIVENHAIN WATER DISTRICT (760)753-6466 * BUENA SANITATION DISTRICT (760)726-1340 x1330 * AS APPROPRIATE 1. ACTUAL STRUCTURAL SECTIONS WILL BE DETERMINED AFTER "R" VALUE TESTS HAVE BEEN CONDUCTED BY A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, ON THE PREPARED BASEMENT SOIL. THE "R" VALUE TESTS AND THE ENGINEERED STRUCTURAL SECTION MUST BE SUBMITTED TO THE ENGINEERING INSPECTOR FOR REVIEW AND APPROVAL A MINIMUM OF TWO (2) CITY WORKING DAYS BEFORE THE WORK BEGINS. 2. STREET LIGHTS SHALL BE INSTALLED AS SHOWN ON THESE PLANS, UNDERGROUND CONDUIT RUNS, SERVICE POINTS AND HAND-HOLES SHALL BE SHOWN ON THE "AS-BUILT" PLANS. NO DIRECT BURIAL STREET LIGHT FOUNDATIONS WILL BE ALLOWED. ALL LUMINAIRES SHALL BE "CUT OFF" TYPE. 3. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF CURBS, CROSS GUTTERS OR SURFACING OF STREETS. 4. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 5. WHEELCHAIR RAMPS SHALL BE INSTALLED PER REQUIREMENTS OF TITLE 24, CALIFORNIA ADMINISTRATIVE CODE. 6. STREET TREES SHALL BE INSTALLED PER SECTION VI OF THE CITY OF CARLSBAD LANDSCAPE MANUAL. 7. FIRE HYDRANT MARKERS SHALL BE PLACED IN THE STREET WITHIN THE LIMITS OF WORK OF THIS PLAN PER SDRS DWG M19. 8. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTURBED BY THIS WORK SHALL BE REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS ACT. 9. TWO (2) SETS OF SURVEY (CUT) SHEETS SHALL BE PROVIDED TO THE CITY ENGINEERING INSPECTOR. 10. STREET LIGHTS SHALL BE 4,000 LUMEN (25-32 WATT) #ERLI-0-04-C5-30-A-GRAY-L4 GE-EVOLVE-LED. 1. SEWER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CITY OF CARLSBAD ENGINEERING STANDARDS (LATEST EDITION), VOLUME 1- GENERAL DESIGN STANDARDS, CHAPTER 6-DESIGN CRITERIA FOR GRAVITY SEWER LINES AND APPURTENANCES, AND VOLUME 3 - STANDARD DRAWINGS AND NOTES AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, LATEST EDITION (GREEN BOOK). 2. BEFORE ANY CONNECTION TO THE CITY'S EXISTING SYSTEM, A PERMIT SHALL BE OBTAINED FROM THE CITY. IT MUST BE SIGNED AND APPROVED BY THE CITY ENGINEER OR DESIGNEE. 3. BEFORE CONSTRUCTION BEGINS IN ANY PUBLIC RIGHT OF WAY, A CITY RIGHT OF WAY PERMIT SHALL BE REQUIRED. 1. WATER & RECYCLED WATER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CITY OF CARLSBAD ENGINEERING STANDARDS" (LATEST EDITION) VOLUMES 2 & 3. 2. BEFORE ANY CONNECTION OR SHUT DOWN OF VALVES ON EXISTING C.M.W.D. LINES, A PERMIT SHALL BE OBTAINED FROM THE C.M.W.D. OFFICE AND MUST BE SIGNED AND APPROVED BY THE CITY OF CARLSBAD'S DEPUTY CITY ENGINEER AND THE UTILITY OPERATIONS' PUBLIC WORKS MANAGER. 3. ALL INSPECTION REQUESTS OTHER THAN FOR PRECONSTRUCTION MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 2:00 P.M. ON THE WORK DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2:00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 4. NO TREES OR STRUCTURES SHALL BE ALLOWED IN THE WATER LINE EASEMENT, ALL EXISTING TREES AND STRUCTURES SHALL BE REMOVED PRIOR TO COMMENCEMENT OF WORK - ANY EXCEPTIONS SHALL REQUIRE WRITTEN PERMISSION FROM THE DISTRICT ENGINEER. 5. ALL BURIED COPPER PIPING AND APPURTENANCES SHALL BE PROTECTED BY MEANS OF CATHODIC PROTECTION. IF DEVELOPER/OWNER CONDUCTS A SOILS TEST REPORT AND DEMONSTRATES THAT PROTECTION CAN BE PERFORMED IN ANOTHER MANNER, THE DISTRICT ENGINEER WILL CONSIDER AN ALTERNATIVE FORM OF PROTECTION. 6. THE EXACT HORIZONTAL AND VERTICAL ALIGNMENT AND TYPE OF MATERIALS OF THE FIRE LINE LOCATED BETWEEN THE DETECTOR CHECK VALVE AND BUILDING SHALL BE DETERMINED BY THE CITY OF CARLSBAD FIRE MARSHAL. 7. ALL POTABLE WATER SERVICES SHALL BE 1" AND ALL METERS SHALL BE 1" (UNLESS OTHERWISE NOTED ON PLANS). 8. ALL WATER METER BOXES SHALL BE 17" X 30" X 12" POLYMER CONCRETE AS MANUFACTURED BY ARMORCAST OR EQUAL. 9. MINIMUM SPACING BETWEEN POTABLE WATER SERVICES AND SEWER LATERALS SHALL BE 10 FEET. 10. THE TOP OF WATER METER BOXES SHALL BE FLUSH WITH THE FINISHED SURFACE GRADE. 11. CONSTRUCTION OF WATER MAINS AND RECYCLED WATER MAINS SHALL ADHERE TO THE "CRITERIA FOR THE SEPARATION OF WATER MAINS AND SANITARY SEWERS" PUBLISHED BY THE STATE OF CALIFORNIA'S DEPARTMENT OF HEALTH SERVICES. 12. AXIAL DEFLECTION AT THE PIPE JOINTS IS NOT ALLOWED. THE USE OF A HIGH- DEFLECTION COUPLING AT A PIPE JOINT MAY BE PERMITTED BY THE INSPECTOR ON A CASE BY CASE BASIS NOT TO EXCEED 4 DEGREES TOTAL DEFLECTION PER COUPLING (2 DEGREES/EACH GASKET). USE CERTAINTEED "VINYL-IRON" H.D. FOR C900. 13. BEFORE CONSTRUCTION BEGINS IN ANY PUBLIC RIGHT OF WAY, A CITY RIGHT OF WAY PERMIT SHALL BE REQUIRED. 14. NO CUTTING OR SNAPPING OF ASBESTOS CEMENT PIPE (ACP) IS PERMITTED. CONTRACTOR SHALL REMOVE ACP TO NEAREST COUPLING AND INSTALL ACP X PVC ADAPTORS AND THE NECESSARY PVC SIZE AND CLASS PIPE TO INSTALL THE TEE AT THE STATION. 15. PRIOR TO BACKFILL, INSTALL TRACER WIRE ON TOP OF PIPE AND SECURE IN PLACE WITH 2-INCH WIDE PLASTIC ADHESIVE TAPE AT MAXIMUM 10-FOOT INTERVALS. WIRE TO ENTER VALVE STANDS BY MEANS OF DRILLED HOLE IN PIPE STAND WALL JUST BELOW 4TTBOX. WIRE IS NOT TO INTERFERE WITH VALVE NUT OPERATION. RUN TRACER WIRE CONTINUOUSLY ALONG PIPE AND TERMINATE IN ADJACENT VALVE BOXES FOR BURIED ASSEMBLIES OR BURIED VALVES. WHERE BURIED SPLICES OCCUR, USE AN ELECTRICAL EPOXY RESIN SUCH AS SCOTCHCAST, OR APPROVED EQUAL. PROVIDE 24 INCHES OF COILED WIRE AT ACCESS POINTS FOR ATTACHMENTS OF PIPE LOCATING EQUIPMENT. EACH INSTALLED RUN OF PIPE SHALL BE CAPABLE OF BEING LOCATED USING THE TRACER WIRE. PROTECT WIRE INSULATION FROM DAMAGE DURING INSTALLATION AND BACKFILLING. WIRE INSULATION THAT IS BROKEN, CUT, OR DAMAGED SHALL BE REPLACED. TRACER WIRE SHALL BE AWG NO. 8 STRANDED COPPER WIRE WITH HIGH MOLECULAR WEIGHT POLYETHYLENE (HMW/PE) INSULATION SPECIFICALLY DESIGNED FOR DIRECT BURIAL IN CORROSIVE SOIL OR WATER. POLYETHYLENE INSULATION SHALL CONFORM TO ASTM D 1248, TYPE 1, CLASS C. WIRES WITH CUT OR DAMAGED INSULATION ARE NOT ACCEPTABLE AND REPLACEMENT OF THE ENTIRE WIRE WHICH HAS BEEN DAMAGED WILL BE REQUIRED AT THE CONTRACTOR'S EXPENSE. 16. CONTRACTOR TO SUBMIT E-28 FORM TO CM&I, MINIMUM 2 WEEKS PRIOR TO SCHEDULED WATER SHUTDOWN. I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. 12-31-2026 80356 TYLER G. LAWSON, R.C.E. DATE: REGISTRATION EXPIRATION DATE: R.C.E. NO.: BY: TELEPHONE: (858) 259-8212 CITY, STATE: SAN DIEGO, CA 92110 ADDRESS: 1911 SAN DIEGO AVE, SUITE 100 FIRM: PASCO, LARET, SUITER, AND ASSOCIATES, INC. TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON: JANUARY 15,2024 BY: PASCO, LARET, SUITER & ASSOCIATES TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS. THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S): 155-251-18 & -19 THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N_____________ E________________ (CCS 83) ADDRESS: 2502 & 2518 JEFFERSON STREET CARLSBAD, CA 92008 366 1665 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS 3. THIS SET OF PLANS 4. RESOLUTION NO 7543 DATED 5/21/2025 5. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK) 6. SOILS REPORT AND RECOMMENDATIONS BY GEOTEK, INC.: JOB. NO. 3988-SD DATED 5/14/2024 & 7/16/2025 7. SAN DIEGO REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDITIONS DATED _________ 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED________ 10. STORM WATER POLLUTION PREVENTION PLAN (TIER 2) PREPARED BY: ___________. 11. STORM WATER QUALITY MANAGEMENT PLAN PREPARED BY: ___________ DATED: _________________ 12. CALIFORNIA STORM WATER BMP CONSTRUCTION HANDBOOK AND CALTRANS CONSTRUCTION SITE BMP MANUAL PLSA PLSA N/A N/A PROPERTY LINE RIGHT-OF-WAY ADJACENT LOT LINE CENTERLINE OF ROAD EXISTING CONTOUR PROPOSED CONTOUR EXISTING WATER MAIN (SIZE AND MATERIAL PER PLAN) EXISTING WATER SERVICE (TO BE REMOVED) EXISTING SEWER MAIN (SIZE AND MATERIAL PER PLAN) EXITING GAS MAIN (SIZE PER PLAN) PROPOSED 6" PCC CURB AND GUTTER PROPOSED 6" PVC SEWER LATERAL AND CLEANOUT PROPOSED 2" DOMESTIC WATER SERVICE W/ 2" METER AND BACKFLOW PROPOSED 1" IRRIGATION SERVICE W/ 1" METER AND BACKFLOW PROPOSED 6" FIRE WATER SERVICE & BACKFLOW PROPOSED 14" PVC WATER MAIN PROPOSED 14" X 6" X 14" DI TEE PROPOSED AC SAWCUT CALTRANS VEHICULAR STOPPING SIGHT DISTANCE VIEW CORRIDOR PROPOSED TRENCHING AND RESURFACING W/ AC PAVEMENT PROPOSED 4" PCC SIDEWALK / PAVEMENT PROPOSED 3" AC GRIND AND OVERLAY PROPOSED 4" AC OVER 6" AB** PROPOSED 4' X 8' TREE WELL BMP (20' CANOPY) PROPOSED PCC DRIVEWAY APRON PROPOSED 3" PVC SIDE WALK UNDER DRAIN PROPOSED 3" X 3' CURB OUTLET PROPOSED 7.5" PCC CROSS GUTTER PROPOSED STREET TREE (PER SEPARATE LANDSCAPE PLANS SHOWN FOR REFERENCE ONLY) PROPOSED CURB RAMP WITH DOMES W W S S S S F F G G W W W W SDRSD G-2* CARLSBAD S-7 & S-8 CMWD W-4 & W-6 CMWD W-3 & W-6 CMWD W-7 & W-9 CARLSBAD GS-26 & GS-28 SDRSD G-7* 148 LF 1 EA 1 EA 1 EA 1 EA 120 LF 200 LF 1,850 SF 4,405 SF W W W 2 EA 2502 & 2518 JEFFERSON STREET CARLSBAD, CA 92008 APN: 155-251-18 & -19 1 EA 220 SFSDRSD G-14A* 140 140 350 SF THE NORTHERLY ONE-HALF OF LOT 11 AND ALL OF LOT 12 BLOCK "C" OF THE RESUBDIVISION OF A PORTION OF SUNNYSLOPE TRACT, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 995, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 6 1906. EXPECTING THEREFORM THE EASTERLY 57.5 FEET THEREOF. ALSO EXCEPTING THEREFORM THAT PORTION THEREOF DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHWEST CORNER OF SAID LOT 12; THENCE SOUTHERLY ALONG THE WESTERLY LINE OF SAID LOT 12, A DISTANCE OF 12.49 FEET TO THE BEGINNING OF A TANGENT CURVE CONCAVE SOUTHERLY, HAVING A RADIUS OF 14.00 FEET; THENCE NORTHEASTERLY ALONG SAID CURVE, THROUGH CENTRAL ANGLE OF 63° 10' 04", AN ARE DISTANCE OF 15.43 FEET TO A POINT ON THE NORTHERLY LINE OF SAID LOT 12; THENCE WESTERLY ALONG THE NOTHERLY LINE OF SAID LOT 12 TO THE POINT OF BEGINNING. APN: 155-251-18 LOT 10 AND THE SOUTH HALF OF LOT 11, BLOCK "C" OF RESUBDIVISION OF PORTINO OF SUNNYSLOPE TRACT, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 995, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY . EXCEPTING THEREFROM THE EASTERLY 57.5 FEET THEREOF APN: 155-251-19 SOUTH SIDEWALK NEAR THE EAST END OF LAS FLORES DRIVE BRIDGE OVER INTERSTATE 5, BASED ON POINT NUMBER 139. ROS 21047 CR 13447 ROS 12779 MAP 3845 MAP 995 MAP 486 DWG 118-9 DWG 146-8 DWG 159-3 DWG 365-2 THE CALIFORNIA COORDINATE SYSTEM OF NAD83 (CCS-83), ZONE 6, EPOCH 1991.35, AS DETERMINED LOCALLY BY A LINE BETWEEN STATIONS CLSB130 AND CADT 5-50.7 BEING A GRID BEARING OF N 21° 00' 57" E AS DERIVED FROM GEODETIC VALUES SHOWN ON RECORD OF SURVEY 17271, CITY OF CARLSBAD SURVEY CONTROL NETWORK SDRSD D-27 SDRSD D-25 TYPE A 1 EA 4 EA STORMWATER REQUIREMENTS THAT APPLY: STANDARD STORMWATER REQUIREMENTS PRIORITY PROJECT REQUIREMENTS YES NO EXEMPT FROM HYDROMODIFICATION? YES NO EXEMPT FROM TRASH CAPTURE? W W SDRSD G-12*160 SF TOM ST. CLAIR FOR: 2502 & 2518 JEFFERSON LLC SEE DETAILS ON SHEET 4 1. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ALL SIGNING AND STRIPING. 2. ALL SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LATEST VERSION), THE CALTRANS STANDARD PLANS AND SPECIFICATIONS (LATEST VERSION), THESE PLANS AND THE SPECIAL PROVISIONS. 3. ALL SIGNING AND STRIPING IS SUBJECT TO THE APPROVAL OF THE "CITY ENGINEER" OR HIS REPRESENTATIVE, PRIOR TO INSTALLATION. 4. ANY DEVIATION FROM THESE SIGNING AND STRIPING PLANS SHALL BE APPROVED BY THE "CITY ENGINEER" OR HIS REPRESENTATIVE PRIOR TO ANY CHANGE IN THE FIELD. 5. ALL STRIPING SHALL BE REFLECTIVE PER CALTRANS SPECIFICATIONS. STRIPING SHALL BE REPAINTED TWO WEEKS AFTER INITIAL PAINTING. 6. ALL PERMANENT SIGNAGE SHALL BE REFLECTIVE PER ASTM DESIGNATION D4956 AND SHALL USE TYPE IV PRISMATIC REFLECTIVE SHEETING (HIGH INTENSITY PRISMATIC OR EQUAL) UNLESS OTHERWISE SPECIFIED. R1-1 “STOP”, R1-2 "YIELD", R2-1 “SPEED LIMIT" AND STREET NAME SIGNS SHALL USE TYPE IX PRISMATIC CUBE-CORNER REFLECTIVE SHEETING (DIAMOND GRADE VIP OR EQUAL). 7. PRIOR TO FINAL ACCEPTANCE OF STREET IMPROVEMENTS, ALL STREET STRIPING AND MARKINGS WITHIN A 500' PERIMETER OF THE CONSTRUCTION PROJECT WILL BE RESTORED TO A "LIKE NEW” CONDITION, IN A MANNER MEETING THE APPROVAL OF THE CITY INSPECTOR. 8. EXACT LOCATION OF STRIPING AND STOP LIMIT LINES SHALL BE APPROVED BY THE "CITY ENGINEER" OR HIS REPRESENTATIVE PRIOR TO INSTALLATION. 9. CONTRACTOR SHALL REMOVE ALL CONFLICTING PAINTED LINES, MARKINGS AND PAVEMENT LEGENDS BY GRINDING. DEBRIS SHALL BE PROMPTLY REMOVED BY THE CONTRACTOR. 10. ALL PAVEMENT LEGENDS SHALL BE THE LATEST VERSION OF THE CALTRANS STENCILS. 11. LIMIT LINES AND CROSSWALKS SHALL BE FIELD LOCATED. 12. ALL CROSSWALKS, LIMIT LINES, STOP BARS, PAVEMENT ARROWS AND PAVEMENT SHALL BE THERMOPLASTIC UNLESS OTHERWISE SPECIFIED. PREFORMED THERMOPLASTIC ARROWS AND LEGENDS SHALL NOT BE ACCEPTABLE. 13. ALL BIKE LANE LEGENDS SHALL BE HELMETED BICYCLIST SYMBOL AND ARROW PER CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FIGURE 9C-3 AND PAINTED, UNLESS OTHERWISE SPECIFIED. 14. SIZE OF SIGNS SHALL BE BASED UPON THE RECOMMENDED SIGN SIZES FOUND IN THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES UNLESS OTHERWISE SPECIFIED. 15. SIGRI POSTS SHALL BE SQUARE PERFORATED STEEL TUBING WITH BREAKAWAY BASE PER SAN DIEGO REGIONAL STANDARD DRAWING M-45. 16. WHEN A SIGN IS ATTACHED TO A POLE, IT SHALL BE MOUNTED USING A STANDARD CITY OF CARLSBAD APPROVED MOUNTING BRACKET WITH STRAPS 17. EXISTING SIGNS REMOVED BY THE CONTRACTOR SHALL BE DELIVERED BY THE CONTRACTOR TO THE CITY OF CARLSBAD PUBLIC WORKS YARD AT 405 OAK AVENUE. 18. ALL SIGNS SHOWN ON THESE PLANS SHALL BE NEW SIGNS PROVIDED AND INSTALLED BY THE CONTRACTOR EXCEPT THOSE SIGNS SPECIFICALLY SHOWN AS EXISTING TO BE RELOCATED OR TO REMAIN. 19. FIRE HYDRANT PAVEMENT MARKERS SHALL CONFORM TO THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES AND SAN DIEGO REGIONAL STANDARD DRAWING M-19. 20. ALL NEW AND RELOCATED SIGNS SHALL BE CLEARLY VISIBLE, NOT BLOCKED BY ANY OBSTRUCTION. THE CONTRACTOR IS RESPONSIBLE TO TRIM OR REMOVE ANY VEGETATION BLOCKING THE NEW OR RELOCATED SIGNS. 21. ALL NEW STRIPING AND PAVEMENT LEGENDS SHALL BE CAT-TRACKED AND APPROVED BY THE TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE BEFORE FINAL INSTALLATION. THE CONTRACTOR SHALL NOTIFY THE TRANSPORTATION DIRECTOR OR HIS REPRESENTATIVE AFTER COMPLETING THE LAYOUT AND AT LEAST 3 WORKING DAYS PRIOR TO COMMENCING INSTALLATION OF STRIPING, LEGENDS, AND MARKERS. PAVEMENT LEGENDS SHALL BE MARKED OUT IN FULL SIZE FOR REVIEW. 4 EA SDRSD G-27 1 EA 01/09/26 NF NF OCTOBER 2025 QUALITY ASSOCIATION Docusign Envelope ID: F6F4EAEE-BFAF-4149-AEEB-7633014A93AF 5/4/2026 GRAPHIC SCALE: 1" = 10' 0 10'20'30' J:\ACTIVE JOBS\4138 RINCON JEFFERSON\CIVIL\DRAWING\IMPROVEMENT PLANS SA V E D A T E : 2 0 2 6 - 4 - 9 - P L O T D A T E : 2 0 2 6 - 4 - 9 1 0 : 1 6 A M - F I L E N A M E : J : \ A C T I V E J O B S \ 4 1 3 8 R I N C O N J E F F E R S O N \ C I V I L \ D R A W I N G \ I M P R O V E M E N T P L A N S \ 4 1 3 8 - C V - I P - 0 2 - B V W . d w g PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 "AS BUILT" DATE INSPECTOR DATE REVIEWED BY: 4 PLSA 4138 BAK CT 2024-0004 IMP 2025-0013 552-6 JEFFERSON STREET HOMES PUD 2024-0004 CDP 2024-0021 ALL EXISTING MONUMENTS TO BE PROTECTED IN PLACE. ANY MONUMENTS DESTROY DURING CONSTRUCTION SHALL BE REPLACED BY A LICENSED SURVEYOR AND PROPER DOCUMENTATION SHALL BE FILED WITH THE COUNTY RECORDER 1. UTILITIES ARE KNOWN TO EXIST IN THE AREA. INFORMATION SHOWN HEREON IS PER BEST AVAILABLE RECORD INFORMATION. EXACT HORIZONTAL AND VERTICAL LOCATION OF EXISTING UTILITIES UNKNOWN. CONTRACTOR TO VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO ORDERING MATERIALS AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD OF ANY DISCREPANCIES UPON DISCOVERY. 2. REMOVE EXISTING WATER SERVICES PER CITY OF CARLSBAD STANDARD SPECIFICATION 15000-3.12.A. REMOVE EXISTING SEWER LATERALS PER CITY OF CARLSBAD STANDARD 15000-3.12A. 3. EXISTING GAS AND ELECTRICAL SERVICE TO BE REMOVED PER SEPARATE SDGE WORK ORDER. SITE NOTES EXISTING SURVEY MONUMENT TO BE PROTECTED IN PLACE. MONUMENT SHALL BE REPLACED BY A LICENSED LAND SURVEYOR WHO SHALL FILE A CORNER RECORD WITH COUNTY IF DISTURBED OR DESTROYED. INSTALL 6" PVC SEWER LATERAL PER CITY OF CARLSBAD S-7 W/ CUT IN WYE CONNECTION PER S-8; WYE FITTING ROTATED 11.25 DEG FROM HORIZONTAL WITH 11.25 AND CARLSBAD S-10 TYPE C 3" AC GRIND AND OVERLAY SAWCUT EXISTING AC PAVEMENT SEE DETAIL SHEET 4 TRENCH AND RESURFACING W/ AC PAVEMENT PER CITY OF CARLSBAD GS-26, GS-28 INSTALL 1" IRRIGATION SERVICE METER AND BACK FLOW PER CMWD W-3 & W-6 INSTALL 2" DOMESTIC WATER SERVICE, W/ 2" METER AND BACKFLOW PER CMWD W-4 & W-6 INSTALL 6" FIRE SERVICE AND WILKINS 475DA 6" RPDA OR APPROVED EQUAL PER CMWD W-7 & W-9 CONSTRUCTION NOTES CONSTRUCT 6" PCC CURB AND GUTTER PER SDRSD G-2 SEE DATA TABLE THIS SHEET CONSTRUCT 20-FT WIDE PCC DRIVEWAY APRON PER SDRSD G-14A CONSTRUCT 4" PCC SIDEWALK PER SDRSD G-7 CONSTRUCT TYPE A PCC PED RAMP PER SDRSD G-27A SEE DETAIL SHEET 4 150-FT SIGHT DISTANCE CORRIDOR PER CALTRANS HIGHWAY DESIGN MANUAL INSTALL DUAL 3" PVC SIDEWALK UNDER DRAIN PER SDRSD D-27 INSTALL 2.7' X 3.0' THRUST BLOCK (8.0 SF MIN.) PER CMWD DWG W-19A STREET TREE PER SEPARATE LANDSCAPE PLANS DWG NO. 552-6L SHOWN FOR REFERENCE ONLY 1 2 3 4 5 10 11 12 13 9 6 7 8 BUENA VISTA WAY CENTER LINE DATA TABLE #BEARING / DELTA LENGTH RADIUS 550.01 -N 89° 25' 35" W CURB & GUTTER DATA TABLE #BEARING / DELTA LENGTH RADIUS 1 REMARKS 6" C&G SDRSD G-276.4'N 89° 25' 35" W - STREET STA. OF LAT @ MAIN IE @ MAIN LENGTH DROP TO MAIN LAT EL. @ PL (IE) LAT SLOPE GROUND EL. @ PL DEPTH BELOW PL (PL TO IE) UPSTREAM MH RIM EL. BACKWATER VALVE REQ'D 2+02.76 56.3'57.5 IE0.70'24.3'67.2 NO6.3'2.0%63.8' SEWER LATERAL DATA TABLE - 6" PUBLIC SEWER LATERAL 2 BUENA VISTA WAY IMPROVEMENTS PLAN VIEW - BUENA VISTA WAY IMPROVEMENTS SCALE: 1" =10' 14 CURB AND SIDEWALK NOTE: REPLACE PCC CURB, GUTTER AND SIDEWALK TO NEAREST JOINT PER CITY STANDARDS WATER MAIN SHUTDOWN NOTE: EXCEPTED SHUTDOWN OF EXISTING 14" WATER MAIN FOR INSTALLATION OF WATER SERVICES. CONTRACTOR SHALL SUBMIT E-28 FORM TO CM&I 2 WEEKS PRIOR TO SCHEDULED SHUTDOWN. AC WATER MAIN REPLACEMENT NOTE: REMOVE AND REPLACE EXISTING 14" AC WATER MAIN TO NEAREST JOINT WITH 14" PVC WATER MAIN PER ENGINEERING STD VOL.2 - 3.3.11.M. USING APPROVED TRANSITION COUPLINGS. RECONNECT EXISTING WATER SERVICE AFFECTED BY UPSIZING WITH SADDLE TAP CONNECTION EASEMENTS - PROPOSED INDICATES PROPOSED DEDICATION GRANTED TO THE CITY OF CARLSBAD FOR PUBLIC ROADWAY AND UTILITY PURPOSES INDICATES PROPOSED EASEMENT GRANTED TO THE CITY OF CARLSBAD FOR PEDESTRIAN ACCESS PURPOSES 1 2 15 16 18"TP18"TP 64.79 64.28 63.4963.00 63.35 62.85 62.67 65.21 64.63 62.89 TC 62.42 FL 63.07 TC 62.56 FL 62.81 TC 62.81 FL62.78 TC 62.79 FL 63.30 TC 62.81 FL 63.31 TC 62.81 FL 63.45 TC 62.96 FL 63.87 TC 63.39 FL 64.12 TC 63.64 FL 64.36 TC 63.90 FL 64.27 64.68 64.50 65.07 63.64 TC 63.18 FL 64.70 64.9164.48 63.32RIM 53.72BOT 18"TP18"TP E E G S W X X X X X X X X X X X X X X X OE OE OE OE OE OE OE OE OE OE OE OE OE OE 65 65 65 65 65 64 64 64 6464 64 64 64 63 63 63 63 63 63 X X X X XX X S S S S S S S S S S S S X X S S S G G G G W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S W W W IR R IR R IR R F F F F G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G W W W E E E E E E E E E E E EE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE X X X X X X E E E E E SD F F F F G G G G G G G G G G G G G G G G GW W W W W W W W W W W W W W W W W W W W W W W W W W W W E E E W SD SD SDSSS W W W W W W W W W S0 ° 3 6 ' 5 2 " W 1 5 0 . 1 3 ' L=15.43' R=14.00 =63.17 S89°25'35"E 149.82' BUENA VISTA WAY JE F F E R S O N S T R E E T 25 . 0 ' EXISTING DRIVEWAY APRON TO BE REMOVED; REPLACE WITH PCC SDWK EXISTING SEWER MH (63.3 RIM) (53.7 IE) EXISTING PCC CROSS GUTTER TO REMAIN EXISTING 14" AC WATER MAIN PER DWG 159-3 EXISTING 8" VCP SEWER MAIN PER DWG 118-9 ST A . 2 + 0 2 . 7 6 ~ 0 . 8 ' R T 57 . 0 I E @ L A T (5 6 . 3 I E @ M A I N ) EXISTING FIRE HYDRANT SERVICE AND HYDRANT TO REMAIN EXISTING OVERHEAD UTILITY TO BE REMOVED EXISTING OVERHEAD UTILITY TO REMAIN 6. 0 ' EXISTING 8" VC SEWER MAIN PER DWG 118-9 7. 5 ' REMOVE AND REPLACE EXISTING PCC CROSS GUTTER TO NEAREST JOINT LIMITS OF PROPOSED GRIND AND OVERLAY 30 . 0 ' 55 . 0 ' EXISTING PCC CURB AND GUTTER TO REMAIN EXISTING POWER POLE TO REMAIN EXISTING POWER POLE TO REMAIN 5.0' EXISTING OVERHEAD UTILITY TO REMAIN 2.0' 1+00 2+00 3+00 40 + 0 0 BUENA VISTA WAY STA. 1+00 = JEFFERSON ST. STA. 39+58.13 BUENA VISTA WAY STA. 2+10.76 = CL PVT DR. STA. 1+00.00 ST A . 2 + 3 0 . 5 0 ~ 7 . 7 5 ' L T CO N N E C T T O N E W 1 4 " P V C MA I N ST A . 2 + 3 5 . 5 0 ~ 7 . 7 5 ' L T CO N N E C T T O N E W 1 4 " P V C WA T E R M A I N ST A . 2 + 3 7 . 5 0 ~ 7 . 7 5 ' L T CO N N E C T T O N E W 1 4 " P V C WA T E R M A I N ST A . 1 + 4 4 . 0 5 ~ 1 7 . 5 ' R T PC R 63 . 3 1 T C ; 6 2 . 8 1 F L ST A . 2 + 4 4 . 8 9 ~ 1 7 . 5 ' R T MA T C H T O E X . C & G (6 4 . 0 T C ) ; ( 6 3 . 5 F L ) ST A . 2 + 1 0 . 7 6 ~ 1 7 . 5 ' R T CL O F 2 0 - F T DR I V E W A Y ST A . 2 + 3 5 . 5 0 ~ 2 4 . 2 5 ' R T IN S T A L L 2 " W A T E R ME T E R P E R C M W D W - 4 ST A . 2 + 3 7 . 5 0 ~ 2 4 . 2 5 ' R T IN S T A L L 1 " W A T E R ME T E R P E R C M W D W - 3 PRIMARY ELECTRICAL CONDUIT PER SEPARATE SDGE WORK ORDER 63.75 FS 63.27 FS 63.41 FS 64.0 FS63.77 FS 63.91 FS 9. 7 % 1. 0 % 2. 0 % MA X 2. 0 % MA X ST A . 1 + 6 5 . 8 3 ~ 7 . 7 5 ' L T EX I S T I N G W A T E R S E R V I C E AN D M E T E R T O B E R E M O V E D SE E N O T E 2 T H I S S H E E T PROJECT SITE SEE DWG 552-6A FOR ONSITE IMPROVEMENTS APN: 151-251-18 & -19 1 1 10 8 7 6 2 4 3 5 5 5 11 12 13 13 9 9 ST A . 2 + 0 7 . 8 4 ~ 1 2 . 5 ' R T CO N N E C T T O G A S M A I N PE R S E P A R A T E S D G E WO R K O R D E R 1 0.7% 63.4 FS 64.45 FS ROW ROW RO W EXISTING PED RAMP TO REMAIN CL CL CL CL PL64.2 FS63.55 FS 9 EXISTING PCC CURB AND GUTTER TO REMAIN (0.6%) ST A . 2 + 4 2 . 5 0 ~ 2 4 . 2 5 ' R T IN S T A L L D U A L 3 " SI D E W A L K U N D E R D R A I N S 63 . 4 8 I E / F L 14 63.8 RIM 57.5 IE N0 ° 3 5 ' 5 2 " E 1 3 7 . 6 8 ' SEE PED RAMP DETAIL SHEET 4 CL EXISTING 1.5" GAS MAIN PER DWG 159-3 EXISTING PCC SIDEWALK TO REMAIN 4' X 4' WELD HOLE ST A . 1 + 8 8 . 0 2 ~ 1 2 . 5 ' R T EX I S T I N G G A S S E R V I C E TO B E R E M O V E D P E R SE P A R A T E S D G E P E R M I T 11 5. 5 ' ST A . 2 + 4 4 . 8 9 ~ 1 8 . 0 ' R T BE G I N S D W K I M P R V . MA T C H T O E X . (6 4 . 3 5 F S ) EXISTING SEWER MH (67.2 RIM) (60.5 IE) REPLACE 14" AC WATER MAIN WITH 14" PVC WATER MAIN SEE NOTE THIS SHEET 4. 0 ' M I N . 1 2 15 1 1616 16 ST A . 2 + 4 4 . 8 9 MA T C H T O E X . C & G (6 4 . 0 T C ) (6 3 . 5 F L ) ST A . 1 + 7 5 . 0 0 63 . 5 1 T C ST A . 2 + 2 3 . 7 6 63 . 8 5 T C ST A . 1 + 9 7 . 7 6 63 . 6 6 T C ST A . 2 + 0 0 . 7 6 63 . 2 7 T C ; 6 3 . 1 9 F L ST A . 2 + 2 0 . 7 6 63 . 4 1 T C ; 6 3 . 3 3 F L ST A . 2 + 1 0 . 7 6 CL O F 2 0 - F T DR I V E W A Y PROPOSED TOP OF CURB DASH DOT REPRESENTS PROPOSED FLOWLINE62 TC 66 TC 62 TC 66 TC PROFILE VIEW - BUENA VISTA WAY TC RT HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' 1+50 2+00 2+50 9 910 0.7%ST A . 1 + 4 4 . 0 5 63 . 3 1 T C ST A . 2 + 7 0 . 0 0 (6 4 . 2 2 T C ) ST A . 2 + 8 7 . 4 9 (6 4 . 4 5 T C ) 2+50 0.7%0.7%(0.6%)PC R SE E D E T A I L SH E E T 4 & PR O F . L E F T (1.1%) DASHED LINE REPRESENTS EX. TOP OF CURBEX. TOP OF CURB ST A . 2 + 4 2 . 5 0 IN S T A L L D U A L 3 " S D W K UN D E R D R A I N S 6 3 . 5 I E / F L 14 0.7% 9 9 9 ST A . 2 + 0 2 . 7 6 ~ 0 . 8 ' R T CO N N E C T T O E X . SE W E R M A I N (5 6 . 3 I E @ M A I N ) 57 . 0 I E @ L A T 1+ 0 0 . 0 0 (6 3 . 3 2 F S ) 1+ 5 0 . 0 0 (6 3 . 5 0 F S ) 2+ 0 0 . 0 0 (6 4 . 2 6 F S ) 2+ 5 0 . 0 0 (6 4 . 5 2 F S ) 3+ 0 0 . 0 0 (6 5 . 2 6 F S ) DASHED LINE REPRESENTS APPROX. EXISTING GRADE AT CENTERLINE TOP OF EXISTING 14" AC WATER MAIN PER DWG 159-3 TOP OF EXISTING 1.5" GAS MAIN PER DWG 159-3 ST A . 2 + 3 0 . 5 0 ~ 7 . 7 5 ' L T CO N N E C T T O N E W 1 4 " P V C WA T E R M A I N ~ 6 1 . 0 T P ST A . 2 + 3 5 . 5 0 ~ 7 . 7 5 ' L T CO N N E C T T O N E W 1 4 " P V C WA T E R M A I N ~ 6 1 . 0 T P ST A . 2 + 3 7 . 5 0 ~ 7 . 7 5 ' L T CO N N E C T T O N E W 1 4 " P V C WA T E R M A I N ~ 6 1 . 0 T P TOP OF EXISTING 8" VC SEWER MAIN PER DWG 118-9 (0.4%) (1.6%)(0.4%)2.0%) ST A . 0 + 9 8 . 7 5 ~ 0 . 8 ' R T EX . S E W E R M H (6 3 . 3 R I M ) (5 3 . 7 I E ) PROFILE VIEW - BUENA VISTA WAY CL HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' 1+00 54 CL 58 CL 62 CL 66 CL 70 CL 2 8 7 6 2+00 3+002+501+5054 CL 58 CL 62 CL 66 CL 70 CL (2.5%) 31.56' 7.89'7.89'7.89'7.89' Δ/4 Δ/4Δ/4Δ/4 PROPOSED TOP OF CURB 63 . 0 7 T C 63 . 1 6 T C 63 . 2 4 T C BU E N A V I S T A A V E ST A . 1 + 4 4 . 0 5 MA T C H T O E X . C & G PC R 6 3 . 3 1 T C JE F F E R S O N S T . ST A . 3 9 + 2 0 . 4 8 MA T C H T O E X . C & G PC R 6 3 . 0 1 T C 0.7% 1+00 1+30 PROFILE VIEW - INT. CURB RETURN SOUTH HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' 62 TC 66 TC 62 TC 66 TC 0.7% DASHED LINE REPRESENTS PED RAMP CUT OUT 0.7% NF NF Docusign Envelope ID: F6F4EAEE-BFAF-4149-AEEB-7633014A93AF 5/4/2026 GRAPHIC SCALE: 1" = 10' 0 10'20'30' J:\ACTIVE JOBS\4138 RINCON JEFFERSON\CIVIL\DRAWING\IMPROVEMENT PLANS SA V E D A T E : 20 2 6 - 4 - 9 - P L O T D A T E : 2 0 2 6 - 4 - 1 7 7 : 5 1 A M - F I L E N A M E : J : \ A C T I V E J O B S \ 4 1 3 8 R I N C O N J E F F E R S O N \ C I V I L \ D R A W I N G \ I M P R O V E M E N T P L A N S \ 4 1 3 8 - C V - I P - 0 3 - J E F F . d w g PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 "AS BUILT" DATE INSPECTOR DATE REVIEWED BY: 4 PLSA 4138 BAK CT 2024-0004 IMP 2025-0013 552-6 JEFFERSON STREET HOMES PUD 2024-0004 CDP 2024-0021 ALL EXISTING MONUMENTS TO BE PROTECTED IN PLACE. ANY MONUMENTS DESTROY DURING CONSTRUCTION SHALL BE REPLACED BY A LICENSED SURVEYOR AND PROPER DOCUMENTATION SHALL BE FILED WITH THE COUNTY RECORDER 1. UTILITIES ARE KNOWN TO EXIST IN THE AREA. INFORMATION SHOWN HEREON IS PER BEST AVAILABLE RECORD INFORMATION. EXACT HORIZONTAL AND VERTICAL LOCATION OF EXISTING UTILITIES UNKNOWN. CONTRACTOR TO VERIFY LOCATION OF EXISTING UTILITIES PRIOR TO ORDERING MATERIALS AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD OF ANY DISCREPANCIES UPON DISCOVERY. 2. REMOVE EXISTING WATER SERVICES PER CITY OF CARLSBAD STANDARD SPECIFICATION 15000-3.12.A. REMOVE EXISTING SEWER LATERALS PER CITY OF CARLSBAD STANDARD 15000-3.12A. 3. EXISTING GAS AND ELECTRICAL SERVICE TO BE REMOVED PER SEPARATE SDGE WORK ORDER. SITE NOTES EXISTING SURVEY MONUMENT TO BE PROTECTED IN PLACE. MONUMENT SHALL BE REPLACED BY A LICENSED LAND SURVEYOR WHO SHALL FILE A CORNER RECORD WITH COUNTY IF DISTURBED OR DESTROYED. 3" AC GRIND AND OVERLAY SAWCUT EXISTING AC PAVEMENT SEE DETAIL SHEET 4 TRENCH AND RESURFACING W/ AC PAVEMENT PER CITY OF CARLSBAD GS-26, GS-28 CONSTRUCT 6" PCC CURB AND GUTTER PER SDRSD G-2 SEE DATA TABLE THIS SHEET CONSTRUCTION NOTES CONSTRUCT 4" PCC SIDEWALK PER SDRSD G-7 CONSTRUCT TYPE A PCC PED RAMP PER SDRSD G-27A SEE DETAIL SHEET 4 INSTALL 4' X 8' TREE WELL BMP WITH 20-FT TREE CANOPY DIAMETER PER DETAIL SHEET 4 CONSTRUCT PCC CROSS GUTTER PER SDRSD G-12 CONSTRUCT 3" X 3' CURB OUTLET PER SDRSD D-25 TYPE A INSTALL 3" PVC SIDEWALK UNDER DRAIN PER SDRSD D-27 STREET TREE PER SEPARATE LANDSCAPE PLANS DWG NO. 552-6L SHOWN FOR REFERENCE ONLY PAINT CURB RED 20-FT FROM EDGE OF PED RAMP 1 2 3 4 6 7 3 JEFFERSON STREET IMPROVEMENTS PLAN VIEW - JEFFERSON STREET IMPROVEMENTS SCALE: 1" =10' JEFFERSON ST CENTER LINE DATA TABLE #BEARING / DELTA LENGTH RADIUS -1 -N 0° 35' 52" W CURB & GUTTER DATA TABLE #BEARING / DELTA LENGTH RADIUS 1 REMARKS 6" C&G SDRSD G-27.2'N 0° 35' 52" W - 8 PROPOSED EASEMENT INFORMATION PROPOSED DEDICATION GRANTED TO THE CITY OF CARLSBAD FOR PUBLIC STREET AND UTILITY PURPOSES PER MAP. 1 9 JEFFERSON STREET SEWER MAIN UPSIZING: REFER TO SEPARATE IMPROVEMENT PLAN DWG 552-6B FOR JEFFERSON STREET SEWER MAIN IMPROVEMENTS BEYOND FRONTAGE. 10 115 CENTERLINE STATIONING NOTE: CENTERLINE STATIONING PER AS-BUILT DWG 146-8 38+00 39+00 50 CL 46 CL 42 CL 54 CL 58 CL 62 CL 66 CL 50 CL 46 CL 42 CL 54 CL 58 CL 62 CL 66 CL PROFILE VIEW - JEFFERSON STREET SEWER MAIN SCALE: 1" =10' HORIZONTAL; 1" = 4' VERTICAL 2 6" C&G SDRSD G-265.1'N 0° 35' 52" W - 39+50 CURB AND SIDEWALK NOTE: REPLACE PCC CURB, GUTTER AND SIDEWALK TO NEAREST JOINT PER CITY STANDARDS 12 13 STRIPING NOTE: EXISTING STREET STRIPING DISTURBED DURING CONSTRUCTION SHALL BE RE-STRIPED TO MATCH EXISTING STRIPING PATTERN **PAINT CURB RED 20-FT FROM EDGE OF RAMP 18 " T P 6" T D 63 . 0 0 63 . 3 5 62 . 9 4 62 . 4 8 62 . 2 6 62 . 8 5 62 . 6 7 64 . 6 3 62 . 7 2 61 . 9 9 T C 61 . 5 1 F L 62 . 1 3 T C 61 . 6 8 F L 62 . 2 3 T C 61 . 7 7 F L 62 . 3 5 T C 61 . 8 6 F L 62 . 1 1 T C 62 . 0 0 F L 62 . 8 9 T C 62 . 4 2 F L 63 . 0 7 T C 62 . 5 6 F L 62 . 8 1 T C 62 . 8 1 F L 62 . 7 8 T C 62 . 7 9 F L 63 . 3 0 T C 62 . 8 1 F L 63 . 3 1 T C 62 . 8 1 F L 63 . 7 4 63 . 9 7 63 . 3 9 64 . 2 7 64 . 5 0 63 . 1 4 63 . 2 1 62 . 8 7 64 . 1 7 63 . 3 5 63 . 3 2 R I M 53 . 7 2 B O T 18 " T P 6" T D G S W W X X X X X OE OE OE OE OE OE OE OE W W W 64 64 64 63 63 63 63 63 63 63 63 63 63 63 62 62 62 62 62 62 62 OEOE OEOE OEOEOE OEOE OEOE XXXXXXXXXXX X X X X S S S S S S S S S S S S S S S S S S S S S S S S S S S S S X X X X W W W W W W S S S S S S S S S S S G G G G G G G G G W W W W X X W W W W E E E E E E E OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE X X X X X X X X X SD SD SDSDSDSDSDSD X G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W S S S S S S S S S S S S S S S W W W W N0°35'52"E 137.68' JEFFERSON STREET EXISTING SEWER MH (63.3 RIM) (53.7 IE) EXISTING PCC CROSS GUTTER TO REMAIN EXISTING 14" AC WATER MAIN PER DWG 159-3 EXISTING 8" VCP SEWER MAIN PER DWG 118-9 EXISTING 8" VC SEWER MAIN PER DWG 118-9 REMOVE AND REPLACE EXISTING PCC CROSS GUTTER TO NEAREST JOINT EXISTING OVERHEAD UTILITY TO REMAIN 1+ 0 0 38+00 39+00 BUENA VISTA WAY STA. 1+00 = JEFFERSON ST. STA. 39+58.13 ROW CL 60 . 0 ' 30 . 0 ' 30 . 0 ' 62.9 FS EXISTING GUY WIRE AND ANCHOR TO REMAIN 62.35 FS 62.5 FS 62.25 FS EXISTING DRIVEWAY APRON TO BE REMOVED; REPLACE WITH PCC SDWK 1 1 EXISTING DRY UTILITY VAULT TO REMAIN EXISTING PCC CURB AND GUTTER TO REMAIN EXISTING WATER SERVICE AND METER TO REMAIN EXISTING WATER SERVICE TO REMAIN EXISTING PCC SIDEWALK TO REMAIN EXISTING PCC CURB AND GUTTER TO REMAIN 6. 0 ' 6. 0 ' 1 EXISTING 14" AC WATER MAIN PER DWG 146-8 EXISTING 42" INTERCEPTOR SEWER MAIN PER DWG 365-2 12 . 0 ' LIMITS OF PROPOSED GRIND AND OVERLAY 4. 0 ' 63.1 FS L=15.43' R=14.00 =63.17 CL CL ST A . 3 8 + 5 6 . 4 6 ~ 8 . 3 7 ' R T EX I S T I N G W A T E R S E R V I C E A N D ME T E R T O B E R E M O V E D S E E NO T E 2 T H I S S H E E T 1 ST A . 3 8 + 2 0 . 0 4 ~ 1 . 4 2 ' R T EX I S T I N G S E W E R L A T E R A L TO B E R E M O V E D S E E N O T E 2 T H I S S H E E T ST A . 3 8 + 5 7 . 2 7 ~ 2 6 . 5 ' R T 4' X 8 ' T R E E W E L L B M P W/ 2 0 - F T C A N O P Y 2 2 8 EXISTING POWER POLE TO REMAIN EXISTING OVERHEAD UTILITIES TO REMAIN 2 1 ST A . 3 8 + 7 5 . 0 6 ~ 2 4 . 0 ' R T MA T C H T O E X . C & G (6 2 . 6 6 T C ) ; ( 6 2 . 1 6 F L ) ST A . 3 7 + 9 1 . 6 7 ~ 2 4 . 0 ' R T MA T C H T O E X . C & G (6 2 . 1 1 T C ) ; ( 6 1 . 6 1 F L ) 2. 0 % MA X . 2. 0 % MA X . 2. 0 % MA X . (62.2 FS) EX. MAILBOX TO BE REMOVED 62.5 FS 62.6 FS 62.75 FS 62.75 FS 62.8 FS PROJECT SITE SEE DWG 552-6 FOR ONSITE IMPROVEMENTS APN: 151-251-18 & -19 ST A . 3 7 + 9 3 . 6 7 ~ 2 4 . 0 ' R T IN S T A L L C U R B O U T L E T 61 . 6 5 I E O U T / F L 63.05 FS 7 6 5 4 4 3 ROW ROW BU E N A VI S T A W A Y EXISTING PED RAMP TO REMAIN 55 9 SEE PED RAMP DETAIL SHEET 4 0.7%(0.7%)0.7% EX. 8" VC SEWER MAIN PER DWG 118-9; UPSIZING OF MAIN TO 12" PVC PER DWG 552-6B 10 ST A . 3 8 + 4 8 . 5 2 ~ 2 4 . 0 ' R T SI D E W A L K U N D E R D R A I N ; 62 . 0 I E / F L 11 EXISTING PCC CURB AND GUTTER TO REMAIN ABANDONED 12" C.L. STEEL WATER MAIN PER DWG 146-8 APN: 151-251-20 62.3 FS62.45 FS 62.6 FS 62.35 FS 62.9 FS 1. 7 % 1. 7 % 1. 7 % 1. 7 % 1. 7 % LIMITS OF STRUCTURAL SOIL ST A . 3 9 + 2 0 . 4 8 ~ 2 4 . 0 ' R T MA T C H T O E X . C & G (6 2 . 9 6 T C ) ; ( 6 2 . 4 6 F L ) 5 63.15 FS 3 5 1 5 REMOVE AND REPLACE CURB AND GUTTER TO NEAREST JOINT PRIMARY ELECTRICAL CONDUIT PER SEPARATE SDGE WORK ORDER ST A . 3 9 + 1 6 . 1 0 ~ 2 4 . 0 ' R T IN S T A L L 3 " P V C S D W K UN D E R D R A I N ; 6 2 . 5 I E 11 3 12 12 1212 **20.0' 13 4 ST A . 3 9 + 1 3 . 7 0 ~ 1 . 2 4 ' R T EX I S T I N G S E W E R L A T E R A L TO B E R E M O V E D S E E N O T E 2 T H I S S H E E T ABANDONED 27" INTERCEPTOR SEWER MAIN PER DWG 365-2 ST A . 3 9 + 2 0 . 4 8 ~ 2 4 . 0 ' R T PC R 63 . 0 1 T C PROPOSED TOP OF CURB DASH DOT REPRESENTS PROPOSED FLOWLINE 62 TC PROFILE VIEW - JEFFERSON STREET TC RT HORIZONTAL SCALE: 1" = 10'; VERTICAL SCALE: 1" = 4' 38+50 ST A . 3 7 + 9 1 . 6 7 MA T C H T O E X . (6 2 . 1 1 T C ) ; ( 6 1 . 6 1 F L ) ST A . 3 8 + 7 5 . 0 6 MA T C H T O E X . (6 2 . 6 6 T C ) (6 2 . 1 6 F L ) 62 TC 66 TC66 TC 39+00 5 5 0.7% 38+00 ST A . 3 9 + 0 0 . 0 0 (6 2 . 8 3 T C ) ST A . 3 9 + 2 0 . 4 8 63 . 0 7 T C ST A . 3 8 + 0 0 . 0 0 62 . 1 5 T C ST A . 3 7 + 8 2 . 9 7 62 . 0 6 T C 37+80 0.7% (0.7%) PC R PR O F I L E S H E E T 2 & SE E D E T A I L S H T 4 39+20 DASHED LINE REPRESENTS EX. TOP OF CURB DASHED LINE REPRESENTS EX. TOP OF CURB ST A . 3 8 + 3 2 . 7 5 CL O F T R E E W E L L B M P 61 . 9 5 F L 8 1.6% PROPOSED TOP OF CURB ST A . 3 7 + 9 3 . 6 7 CL O F C U R B O U T L E T (6 1 . 6 5 I E O U T / F L ) ST A . 3 9 + 1 6 . 1 0 IN S T A L L 3 " S D W K U N D E R DR A I N ; 6 2 . 5 I E / F L ST A . 3 9 + 1 3 . 2 5 (6 2 . 9 6 T C ) 10 11 ST A . 3 8 + 2 5 . 0 0 62 . 3 3 T C ST A . 3 8 + 5 0 . 0 0 62 . 5 0 T C 42" INTERCEPTOR SEWER PER DWG 365-2 (1.18%) ST A . 3 9 + 5 7 . 4 2 ~ 1 . 2 5 ' R T E X . S E W E R M H (6 3 . 3 R I M ) (5 3 . 7 I E ) TOP OF EXISTING 14" AC WATER MAIN PER DWG 146-8 TOP OF EXISTING 2" GAS MAIN PER DWG 146-8 DASHED LINE REPRESENTS APPROX. EXISTING GRADE AT CENTERLINE EX. 8" VC SEWER MAIN PER DWG 118-9; SEE DWG 552-6B FOR PROPOSED IMPROVEMENTS EXISTING 8" VC SEWER MAIN PER DWG 118-9 38 + 0 0 . 0 0 (6 2 . 2 5 F S ) 38 + 5 0 . 0 0 (6 2 . 5 7 F S ) 39 + 0 0 . 0 0 (6 2 . 8 6 F S ) 39 + 5 0 . 0 0 (6 3 . 2 7 F S ) 3 (0.6%)(04%) (0.7%) ST A . 3 8 + 5 6 . 4 6 ~ 8 . 3 7 ' R T EX . W A T E R S E R V I C E T O B E RE M O V E D S E E S I T E N O T E 2 T H I S S H E E T (0.4%) (0.4%) ST A . 3 8 + 2 0 . 0 4 ~ 1 . 4 2 ' R T EX . S E W E R L A T E R A L T O B E RE M O V E D S E E S I T E N O T E 2 TH I S S H E E T ; ( 5 3 . 1 5 I E @ M A I N ) ST A . 3 9 + 1 3 . 7 0 ~ 1 . 2 4 ' L T EX . S E W E R L A T E R A L T O B E RE M O V E D S E E S I T E N O T E 2 TH I S S H E E T ; ( 5 3 . 5 5 I E @ M A I N ) NF NF Docusign Envelope ID: F6F4EAEE-BFAF-4149-AEEB-7633014A93AF 5/4/2026 G G G G G G G G G G E E E E E E E E E E E E E OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE G G G G G G G G G G G 63.25 TC 62.75 FL MATCH TO EX. (63.63 FL) 62.68 FS62.64 FS 63.18 FS 63.14 FS 62.95 FS 62.91 FS 4.0' 4.0' L=15.43' R=14.00 =63.17 63.20 FS 63.24 FS 1.5% 1.0% 7.7% 7.0% 0.8% 1.0% 0.9 % 6.1 ' 7.3 % 8.2' 63.31 TC 62.80 FL PCR 63.08 TC 62.58 FL 63.1 FS 63.01 TC 62.51 FL PCR 1.9% 63.40 FS 1. 7 % 1.7% 1.3% 1.4% MATCH TO EX. (62.7 FS) MATCH TO EX. (63.7 FS) PROPOSED PRIMARY ELECTRICAL CONDUIT PER SEPARATE SDGE WORK ORDER EX. PROPERTY LINE ULT. PROPERTY LINE BUENA VISTA WAY JE F F E R S O N S T R E E T PROJECT SITE SEE DWG 552-6A FOR ONSITE IMPROVEMENTS 0.7% 0. 7 % EX. 1.5" GAS MAIN PER DWG 159-3 EX. PCC CROSS GUTTER TO REMAIN EX. OVERHEAD ELEC. UTILITIES TO REMAIN 1 2 3 3 12.0' 6.0'6.0' 6.5' 6. 0 ' 7. 5 ' 1. 5 ' LA LA 1 1 2 3 4 5 6.5' 0.9% 62.76 FL 62.71 FL 62.59 FL 62.62 FS 62.66 FS 62.61 FL 1.2% 0.7% 0.5 % 0.5 % GU T T E R L I N E SA W C U T L I N E 3.0' MIN 2.0' MIN *STRUCTURAL SECTION TO BE VERIFIED BY PROJECT GEOTECH ENGINEER BASED ON FIELD TESTED R-VALUE 6" 6" PCC CURB & GUTTER PER SDRSD G-2 *STRUCTURAL SECTION 4" AC OVER 6" CLASS II AB OVER NATIVE SUBGRADE COMPACTED TO 95% REL. COMP. COLD PLAN AND OVERLAY (3" MIN. DEPTH) TO PROVIDE SMOOTH TRANSITION EXISTING AC PAVEMENT B B A A 4.0' CLEAR MIN PCC CURB & GUTTER (SIZE PER PLAN) PCC CURB & GUTTER (SIZE PER PLAN) 5" WIDE CURB CUT CENTERED ON TREE WELL (SEE DETAIL D-D) SPLASH PAD PER GS-5.06 20' DIAMETER CANOPY STREET TREE WITH 628 CF MIN STRUCTURAL SOIL LIMITS OF 30 MIL PLASTIC IMPERMEABLE LINER ALONG SIDES OF STRUCTURAL SOIL 6" THICK, 18" DEEPENED EDGE SIDEWALK TREATMENT, SEE SECTION B-B BELOW TREE WELL GRATE COVER 4' X 8' CONSTRUCT CONTIGUOUS PCC SIDEWALK LIMITS OF STRUCTURAL SOIL BELOW (3.5 DEEP X 8' X 22.5') 3" PVC SIDEWALK UNDER DRAIN 4" ATRIUM GRATE; CONNECT TO SIDEWALK UNDER DRAIN 3" PVC 90° BEND 1. 5 5 ' 1. 0 ' 1. 0 ' C C D D 3. 5 5 0 ' G U T T E R D E P R E S S I O N 9" x 30" x 12" DEEP TYPE 1 SPLASH PAD PER SDC DS GS-5.06 (NO. 2 COARSE AGGREGATE ROCK) R=6" (TYP.) 6" PCC C&G PER SDRSD G-02GUTTER LIP 5" CURB CUT OPENING CENTERED AT TREE WELL GUTTER LIP 6" PCC C&G PER SDRSD G-02 LIMITS OF 9" X 30" TREE GRATE SUPPORT STREET FLOW COMPACTED SUBGRADE 8.0' LIMITS OF STRUCTURAL SOIL UNCOMPACTED SUBGRADE 8" 4.0' TREE GRATE FRAME 3" PL 12.0' COMPACTED SUBGRADE 6" PCC C&G PER SDRSD G-2 ROOT BARRIER PER SDRSD L-6 30 MIL PLASTIC IMPERMEABLE LINER 42" DEEP STRUCTURAL SOIL; STRUCTURAL PER A-1 STRUCTURAL SOIL OR APPROVED EQUAL DEEP ROOT TREE BUBBLER PER SDRSD DWG I-4 3" MIN MULCH LAYER 3" OPENING FOR DRAINAGE 30 MIL PLASTIC IMPERMEABLE LINER SPLASH PAD PER SDC GS DS GS-5.06 PCC SIDEWALK PER SDRSD G-7 4" X 8" SMOOTH DOWELS @ 18" OC, GREASED ON ONE END, TYP. ALL SIDES PER SDC GS DS GS-1.00 #4 @ 18" O.C. BOTH WAYS PER SDC GS DS GS 1-.00 CURB CUT PER DETAIL THIS SHEET 4' X 8' COHO TREE GATE FRAME BY URBAN ACCESSORIES; INSTALL GRATE PER MANUFACTER'S SPECIFICATIONS 6" SAND FILTER LAYER ROOT BARRIER PER SDRSD L-6 9" X 30" TREE GRATE SUPPORT ADJACENT LANDSCAPED AREA 6" 3" ATRIUM GRATE; OUTLET DOWNSTREAM THROUGH SIDEWALK UNDERDRAIN ROOT BALL 22.5' UNCOMPACTED SUBGRADE 8" 9.0' 8.0' TREE GRATE FRAME 3" 6" SAND FILTER LAYER ROOT BARRIER PER SDRSD L-6 30 MIL PLASTIC IMPERMEABLE LINER 42" DEEP STRUCTURAL SOIL; STRUCTURAL PER A-1 STRUCTURAL SOIL OR APPROVED EQUAL DEEP ROOT TREE BUBBLER PER SDRSD DWG I-4 30 MIL PLASTIC IMPERMEABLE LINER REMOVE AND REPLACE EXISTING SIDEWALK AS NECESSARY ROOT BARRIER PER SDRSD L-6 3" MULCH 9" X 30" TREE GRATE SUPPORT 4" X 8 SMOOTH DOWELS @ 18" OC, GREASED ON ONE END, TYP. ALL SIDES PER SDC GS DS GS-1.02 #4 @ 18" O.C. BOTH WAYS PER SDC GS DS GS-1.02 INSTALL 30 MIL PLASTIC IMPERMEABLE LINER WHERE CONCRETE IS POURED OVER ENGINEERED SOIL (TYP.) 4' X 8' COHO TREE GATE FRAME BY URBAN ACCESSORIES IRON TREE GRATE FRAME W/ MATTE BLACK FINISH; INSTALL GRATE PER MANUFACTER'S SPECIFICATIONS STREET FLOW COMPACTED SUBGRADE 12" 12" 6" PCC C&G PER SDRSD G-2 CURB CUT PER DETAIL THIS SHEET 30 MIL PLASTIC IMPERMEABLE LINER AND ROOT BARRIER 9" X 30" PCC TREE GRATE SUPPORT PER SDRSD L-4 SPLASH PAD PER GS-5.06 3.42' *0.42 CURB CUT OPENING1.0'1.0' 7"1" 1.42' *REPLACE CURB TO NEAREST JOINT TOP OF 6" PCC C&G TOP OF 6" PCC C&G FLOWLINE (PER PLAN) FLOWLINE (PER PLAN)1" GUTTER DEPRESSION @ TREE WELL1" VERTICAL GUTTER TRANSITION OVER 1' HORIZONTAL 3" PVC SIDEWALK UNDER DRAIN CL 55.0' 30.0'25.0' 7.7' EX. SDWLK 14.3' TRAVEL LANE 9.5' TRAVEL LANE 6.0' SDWK R/W R/W 8.0' PARALLEL PARKING 8.0' PARALLEL PARKING (2.0%)(2.0%)2.0%(2.0%) 1.5' LA PROPOSED 4" PCC CONCRETE SIDEWALK PROPOSED 6" PCC CURB AND GUTTER PROPOSED AC PAVEMENT SAWCUT PER DETAIL THIS SHEET EX 8" VCP SEWER MAIN PER DWG 118-9 EX. 14" AC WATER MAIN PER DWG 159-3 EX 1.5" HP GAS MAIN PER DWG 159-3 EX PCC CONCRETE SIDEWALK EX CURB AND GUTTER EX A.C. PAVING AND SUBGRADE CL NORTH R/W EX. ROW60.0' 30.0'36.0' 6.0' PKWY 16.0' TRAVEL LANE 16.0' TRAVEL LANE 6.0' EX. SDWLK 8.0' PARALLEL PARKING 8.0' PARALLEL PARKING (2.0%)(2.0%)(2.0%)2.0% ULT PL 6.0' DEDICATION FOR PUB. STREET & UTILITY PRURPOSES 6.5' SDWK PROPOSED 4" PCC CONCRETE SIDEWALK PROPOSED 4" PCC CONCRETE SIDEWALK AC PAVEMENT SAWCUT PER DETAIL THIS SHEET EX PCC CONCRETE SIDEWALK EX CURB AND GUTTER EX. 2" GAS MAIN EX A.C. PAVING AND SUBGRADE EXISTING 42" INTERCEPTOR SEWER MAIN PER DWG 365-2 EXISTING 14" AC WATER MAIN PER DWG 146-8 ABANDONED 12" C.L STEEL MAIN PER DWG 146-8 12" PVC SEWER MAIN PER DWG 552-6B 1 1 GRAPHIC SCALE: 1" = 4' 0 4'8'12' J:\ACTIVE JOBS\4138 RINCON JEFFERSON\CIVIL\DRAWING\IMPROVEMENT PLANS SA V E D A T E : 2 0 2 6 - 4 - 9 - P L O T D A T E : 2 0 2 6 - 4 - 9 1 0 : 1 7 A M - F I L E N A M E : J : \ A C T I V E J O B S \ 4 1 3 8 R I N C O N J E F F E R S O N \ C I V I L \ D R A W I N G \ I M P R O V E M E N T P L A N S \ 4 1 3 8 - C V - I P - 0 7 - D E T S . d w g PA S C O , L A R E T , S U I T E R & A S S O C I A T E S 19 1 1 S A N D I E G O A V E N U E , S A N D I E G O C A 9 2 1 1 0 PH : ( 8 5 8 ) 2 5 9 - 8 2 1 2 F A X : ( 8 5 8 ) 2 5 9 - 4 8 1 2 "AS BUILT" DATE INSPECTOR DATE REVIEWED BY: 4 PLSA 4138 BAK CT 2024-0004 IMP 2025-0013 552-6 JEFFERSON STREET HOMES PUD 2024-0004 CDP 2024-0021 TYPICAL DETAIL - AC PAVEMENT SAWCUT NOT TO SCALE PLAN VIEW - CURB CUT @ TREE WELL (BMP 14) NOT TO SCALE NOT TO SCALE NOT TO SCALE PLAN VIEW - CURB CUT @ TREE WELL SDC GS DS GS-5.01 (BMP 14) NOT TO SCALE SECTION C-C CURB CUT @ TREE WELL SDC GS DS GS-5.01 (BMP 14) NOT TO SCALE SECTION D-D CURB CUT @ TREE WELL SDC GS DS GS-5.01 (BMP 14) SECTION A-A TREE WELL W/ GRATE MODIFIED SDC GS 1.02 (LARGE TREE WELL - BMP 14) SECTION B-B TREE WELL W/ GRATE MODIFIED SDC GS 1.02 (LARGE TREE WELL - BMP 14) NOT TO SCALE TREE WELL BMP TO BE MAINTAINED BY JEFFERSON STREET HOMES HOA DETAIL - PED RAMP SCALE: 1" =4' PROPOSED EASEMENT INFORMATION PROPOSED DEDICATION GRANTED TO THE CITY OF CARLSBAD FOR PUBLIC STREET AND UTILITY PURPOSES. 1 CONSTRUCT TYPE A PCC PED RAMP PER SDRSD G-27A REMOVE AND REPLACE EXISTING PCC CROSS GUTTER TO NEAREST JOINT; CONSTRUCT PCC CROSS GUTTER PER SDRSD G-12 CONSTRUCT 4" PCC SIDEWALK PER SDRSD G-7 CONSTRUCTION NOTES 1 2 3 4 DETAILS TYPICAL STREET SECTION - BUENA VISTA WAY NOT TO SCALE TYPICAL STREET SECTION - JEFFERSON STREET NOT TO SCALE CURB & GUTTER DATA TABLE #BEARING / DELTA LENGTH RADIUS 1 REMARKS 6" C&G SDRSD G-27.53'Δ = 21° 33' 58"20.0' 2 0" TO 6" C&G TRANSITION6.11' 3 0" FLUSH CURB4.13' 4 8.23' 5 6" C&G SDRSD G-25.39' 0" TO 6" C&G TRANSITION Δ = 17° 30' 26" Δ = 11° 50' 22" Δ = 23° 33' 44" Δ = 15° 26' 35" 20.0' 20.0' 20.0' 20.0' NF NF Docusign Envelope ID: F6F4EAEE-BFAF-4149-AEEB-7633014A93AF 5/4/2026