HomeMy WebLinkAbout3182 LIONSHEAD AVE; ; FA120056; Permit6/30/26, 10:06 AM FA120056 Permit Data
City of Carlsbad
Fire Alarm Permit
Permit No: FA 120056
Job Address: 3182 LIONSHEAD AV Status: APPROVED
Permit Type: FALARM Applied 12/10/2012
Parcel No: 2218801000 Approved: 12/10/2012
Lot#: 0
Reference No.: Issued: 12/10/2012
PC#: Inspector:
Project Title: TAYLORMADE GOLF ADDITION OF 4 DUCT DETECTORS TO
EXISTING FA SYSTEM
Applicant:
DYNALECTRIC COMPANY
9505 CHESAPEAKE DR
SAN DIEGO, CA92123
619-560-0808
about blank
Fees($)
286
Add'I Fees ($)
0
Owner:
GATHERING STORM PROPERTIES LL C
3182 LIONSHEAD AVE
CARLSBAD CA
Total($)
286
Balance($)
0
1/1
Dynalectric
Service & Systems Group
Taylor Made
3182 Lionshead Ave.
Carlsbad, CA 920 I 0
Fire Alarm
Submittal
December 6, 2012
Submitted by:
Mats Mattson
Cl1Y OF CARLSBAD
PIE DlfWl1MENT
APPROVED
~ to field llllpectlon 111d 1'91,; I al
tllill; ,iclliillch'II herton, condllloN Ill
... , IIPDMMICI 111d llOlifa.#11• ..
IUIZ ti 11ill"M el U
,,,..._ P!lll■llll"" llllllelllld•--• ,,,., ....
By Data ••
California State License No. 749757
9505 Chesapeake Drive
San Diego, CA 92123
Phone: 858.712.4700
Fax: 858.712.4797
www.dyna-sd.com
A division of Dynalectric
An EMCOR Company
Dyna/ectric
Service & Systems Group
Manufacturer Part#
1. Initiating Devices
Fire Alarm System Submittal
Table of Contents
Description
EST SI GA-SD Duct Smoke Detector
2. CSFM Listing Sheets
California State License No. 749757
9505 Chesapeake Drive
San Diego, CA 92123
Phone: 858.712.4700
Fax: 858.712.4797
www.dyna-sd.com
CSFM Listing
3424-1657:0223
An EMCOR Company
SECTION 1
Initiating Devices
Application
SuperDuct detectors are ideally suited to duct smoke detection
applications where early indication of combustion is required within
the confined space of ventilation ductwork. Its primary purpose
is to provide early warning of an impending fire and to prevent
smoke from circulating throughout the building. It is typically used
to detect smoke in the supply side of the HVAC system but can
provide supervision of the return side as well.
,-Protected premises j
=1 -I ='
I I I I I I I I I
I
Alarm relay i
output
Duct smoke
detector
Duct smoke
detector
Alarm relay
output
I I
I I I I I
l _____ _ I I --------------'
SuperDuct detectors continually sample air flow in the HVAC duct
and initiate an alarm condition whenever smoke is detected. An
alarm is activated when the quantity (percent obscuration) of
combustion products in that air sample exceeds the detector's
sensitivity setting.
Signature Series Intelligence
Uke all Signature detectors, the SIGA-SD features electronic
addressing and issues a dirty sensor warning when it reaches its
preset limit. The dirty sensor warning indicates the sensor is op
erating within its specified limits but is in need of servicing. When
the detector's ability to compensate for environmental changes
has reached its limit, the duct smoke detector signals a trouble
condition.
The S!GA-SD also uses differential sensing to prevent gradual
environmental changes from triggering unwanted alarms. A rapid
change in environmental conditions, such as smoke from a fire,
causes the detector to signal an alarm state, but dust and debris
accumulated over time does not change alarm sensitivity.
Each Signature Series SuperDuct detector contains a microproc
essor that periorms comprehensive self-diagnostics and stores
the results in nonvolatile memory. Stored results include details
such as hours of operation, last maintenance date, and number
of alarms and troubles. This information can be retrieved and
reviewed when desired.
Detector Configuration
The detector assembly cover provides easy access to the smoke
sensor, its wiring connections, sample and exhaust tubes, and the
smoke chamber itself.
Air enters the detector's sensing chamber through a sampling
tube (ordered separately) that extends into the duct and is directed
back into the ventilation system through an exhaust tube (in
cluded). The difference in air pressure between the two tubes pulls
the sampled air through the sensing chamber. When a sufficient
amount of smoke is detected in the sensing chamber, the detector
initiates an alarm.
Page 2 of 4
The sampling tube may be installed from either the duct side of
the assembly or from inside the sensor compartment, as preferred
by the installer. (The exhaust tube must be installed from the duct
side.) Sampling tubes may be rotated in 45-degree increments so
that air-holes can be aligned to allow the unit to be mounted at
virtually any angle relative to the air flow.
In installations where the duct smoke detector's controls and indica
tors are hidden from view, a remote test station or an LEO indicator
can be connected to the detector to provide these functions.
Remote Test Stations
Labor-saving Remote Test/Reset stations provide
alarm testing from the convenience of a remote
location. Tests can be performed quickly and safely
-without having to climb to the roof. Magnetically
operated and key-operated one-gang models are
available. Signature SuperDuct detectors are also
compatible with SIGA-LED remote alarm LED.
Air velocity in the duct as low as 100 ft/min. maintains adequate
air flow into the sensor smoke chamber through air holes in the air
sampling tube and discharges through the exhaust tube. Su
perDuct air sampling tubes must be installed with the inlet holes
facing the airstream. Sampling tubes may be rotated in 45-degree
increments so that air-holes can be aligned to allow the unit to be
mounted in virtually any angle relative to the airflow.
SuperDuct sensors are engineered to operate optimally under the
harsh environmental conditions frequently found in HVAC duc
twork. Nonetheless, before installing the detector, test the duct
air velocity, temperature, and humidity to verify that it is within the
operating range of the SuperDuct detector. Consult the SuperDuct
installation sheet for details.
Dimensions
,._ ______ 6.70"1(22.1cm) -------
,._ ______ 6.15In{20,7em) -------
,__ _____ 7.151n(19,7ctn) ------,
1.60,n
(4.06cm)
22s,n
(5.78 cm)
1.901n
(4,63cm)
85001-0584
Issue 6
Assembly
Sampling tube ----
socket
Exhaust tube
socket
Mounting
Airflow
Wiring
Auxiliary
equipment
1U~
17 16 15
11
Page 3 of 4
-HVACduct
#1 O sheet metal screw (2X)
[1] No more than one remote test station
or LED indicator can be connected to
the detector at the same time. Wiring
is unsupervised. Maximum wire
resistance is 10 ohms per wire.
Data In(+)
Data !n (-)
0 0 0 0
~ Power indicator
Alarm indicator
High-humidity environments
Use the SD-PH Protective Housing when installing SuperDuct
detectors in high-humidity environments. The SD-PH is a weather
ized housing that prevents condensation on the device by insulat
ing the detectors and providing circulated air from the monitored
HVAC duct. The SD-PH also adds a layer of protection against
physical damage to the unit.
Hinged
Cover
Housing
air tube
Detector
conduit holes
The SD-PH is easy to install and service. The hinged and transpar
ent cover provides ready access to the detector, while keeping its
status indicators visible at all times.
Note: The SD-PH Protective Housing is weatherized against out
door air, but it is not intended for direct outdoor exposure.
I Ft,____t: 1
I ·T"
1 -
2
.!1
•
l
i§ii§ii§l~i§li§li§I~
14 13 12 11 10 9 8 7
_h
~ l AJm
Te_!t = 11
DataO
DataO
j
SD-TRK
" SD-TRM [1)
ut(-)
ut (+)
85001-0584
lssue6
Detection & alarm since 1872
U.S.
T 888 378 2329
F 866 503 3996
Canada
Chubb Edwards
T 519 376 2430
F 519 376 7258
Southeast Asia
T : +65 6391 9300
F : +65 6391 9306
India
T : +91 80 4344 2000
F : +91 80 4344 2050
Australia
T +61392391200
F +61 3 92391299
Europe
T+3227251120
F+3227218613
Latin America
T 305 593 4301
F 305 593 4300
utcfireandsecurity.com
@ 2010 UTC Fire & Security.
All rights reserved.
Page4of4
Specifications, detector Specifications, test stations
Dimensions 8.70 x 5.45 x 1.90 inches Remote Test/Reset Stations provide alarm test, trouble
(221 x 138 x 48 mm) indication, and reset capabmty from a remote loca-
Wire size 14 to 22 AWG tioo. They include a one-gang plate, momentary SPST
switch, red alarm LED, and terminal block. Magnet·1cally-
Detection Photoelectric operated models (TRM) or key-operated models (TRK)
method (light scattering principle) North American 1 -gang box
Air velocity 100 to 4,000 ft/min and Compatible Standard 4-in square box, meets the required minimum electrical rating 1-1/2 inches deep, with air pressure differential boxes 1-gang cover
Air pressure 0.005 to 1.00 inches of LED indicators -Alarm (red)
differential water LED type Clear lens --~---·-·--
Sensitivity 0.79 to 2.46 %/ft Wire size 14 to 22 AWG obscuration Resistance per Alarm test 5 seconds wire 1 O Ohms, max.
response time Current LED indicators Alarm (red), Power (green) requirements See contro!!er spec·1ficatlons
Unsupervised and power-LED circuit Voltage: 3 Vdc, max. limited ratings Current: 30 mA, max. Common Quantity: 1 Switch ratings Voltage: 125 Vdc, max. alarm relay Type: Form C (SD-TAK) Current: 4 A, max. Ratings: 2.0 A at 30 Vdc Switch ratings Voltage: 200 Vdc, max. (resistive)
Operating (SD-TRM) Current: 0.5 A, max.
voltage 15.2 to 19.95 Vdc Compatible SuperDuct conventional
Standby: 45 µA Alarm: 45 detectors two-wire and Signature duct
Operating smoke detectors
current µA Inrush: 1 mA Standalone -4°F to 158°F (-20°C to alarm: 18 mA Operating
Temperature (UL): -4 to 158 environment 70°C} Humidity: 93% RH,
'F (-29 to 70 °C). noncondensing
Operating Temperature (ULC): -4 to Storage -4 to 140 °F (-20 to 60 °C) environment 120 °F (-29 to 49 °C) temperature
Relative humidity: 10 to Agency listings UL, ULC, MEA, CSFM
93%, noncondensing
Agency UL, ULC, CSFM, FM, MEA listings
Ordering Information
Description Ship Wt., lb. {kg) Catalog Number
SIGA-SD Intelligent SuperDuct Detector 2.4 11.1 I
Accessories
SD-TS 8-inch sampling tube 0.5 (0.2)
SD-T18 18-inch sampling tube 1.5 (0.7)
SD-T24 24-inch sampling tube 2.7 (1.2)
SD-T36 36-inch sampling tube 3.0 (1.4)
SD-T42 42-inch sampling tube 3.5 (1.6)
SD-T60 6D-inch sampling tube 5.8 (2.6)
SD-T78 78-inch sampling tube 7.5 (3.4)
SD-T120 120-inch sampling tube 11.5 (5.2)
SD-PH Protective housing for high humidity environments 5.5 (2.5)
SIGA-LED Remote alarm LED 1.0 (0.5)
SD-TRM Remote test station, magnetic 1 .0 (0.5)
SD-TAK Remote test station, keyed 1.0 (0.5)
SD-VTK Air velocity test kit (stoppers only, etc) 1.0 (0.5)
SD-GSK Cover gasket kit 0.5 (0.2)
_S~D=-M_A_G==----"-es_t_m_a~g~n_e_t k_it_~--------_____ 0_.5 (0.2)
SIGA-SDPCB Replacement PCB/Signature sensor kit 1.0 (0.5)
85001-0584
Issue 6