HomeMy WebLinkAbout3182 LIONSHEAD AVE; ; FA120056; Permit6/30/26, 10:06 AM FA120056 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA 120056 Job Address: 3182 LIONSHEAD AV Status: APPROVED Permit Type: FALARM Applied 12/10/2012 Parcel No: 2218801000 Approved: 12/10/2012 Lot#: 0 Reference No.: Issued: 12/10/2012 PC#: Inspector: Project Title: TAYLORMADE GOLF ADDITION OF 4 DUCT DETECTORS TO EXISTING FA SYSTEM Applicant: DYNALECTRIC COMPANY 9505 CHESAPEAKE DR SAN DIEGO, CA92123 619-560-0808 about blank Fees($) 286 Add'I Fees ($) 0 Owner: GATHERING STORM PROPERTIES LL C 3182 LIONSHEAD AVE CARLSBAD CA Total($) 286 Balance($) 0 1/1 Dynalectric Service & Systems Group Taylor Made 3182 Lionshead Ave. Carlsbad, CA 920 I 0 Fire Alarm Submittal December 6, 2012 Submitted by: Mats Mattson Cl1Y OF CARLSBAD PIE DlfWl1MENT APPROVED ~ to field llllpectlon 111d 1'91,; I al tllill; ,iclliillch'II herton, condllloN Ill ... , IIPDMMICI 111d llOlifa.#11• .. IUIZ ti 11ill"M el U ,,,..._ P!lll■llll"" llllllelllld•--• ,,,., .... By Data •• California State License No. 749757 9505 Chesapeake Drive San Diego, CA 92123 Phone: 858.712.4700 Fax: 858.712.4797 www.dyna-sd.com A division of Dynalectric An EMCOR Company Dyna/ectric Service & Systems Group Manufacturer Part# 1. Initiating Devices Fire Alarm System Submittal Table of Contents Description EST SI GA-SD Duct Smoke Detector 2. CSFM Listing Sheets California State License No. 749757 9505 Chesapeake Drive San Diego, CA 92123 Phone: 858.712.4700 Fax: 858.712.4797 www.dyna-sd.com CSFM Listing 3424-1657:0223 An EMCOR Company SECTION 1 Initiating Devices Application SuperDuct detectors are ideally suited to duct smoke detection applications where early indication of combustion is required within the confined space of ventilation ductwork. Its primary purpose is to provide early warning of an impending fire and to prevent smoke from circulating throughout the building. It is typically used to detect smoke in the supply side of the HVAC system but can provide supervision of the return side as well. ,-Protected premises j =1 -I =' I I I I I I I I I I Alarm relay i output Duct smoke detector Duct smoke detector Alarm relay output I I I I I I I l _____ _ I I --------------' SuperDuct detectors continually sample air flow in the HVAC duct and initiate an alarm condition whenever smoke is detected. An alarm is activated when the quantity (percent obscuration) of combustion products in that air sample exceeds the detector's sensitivity setting. Signature Series Intelligence Uke all Signature detectors, the SIGA-SD features electronic addressing and issues a dirty sensor warning when it reaches its preset limit. The dirty sensor warning indicates the sensor is op­ erating within its specified limits but is in need of servicing. When the detector's ability to compensate for environmental changes has reached its limit, the duct smoke detector signals a trouble condition. The S!GA-SD also uses differential sensing to prevent gradual environmental changes from triggering unwanted alarms. A rapid change in environmental conditions, such as smoke from a fire, causes the detector to signal an alarm state, but dust and debris accumulated over time does not change alarm sensitivity. Each Signature Series SuperDuct detector contains a microproc­ essor that periorms comprehensive self-diagnostics and stores the results in nonvolatile memory. Stored results include details such as hours of operation, last maintenance date, and number of alarms and troubles. This information can be retrieved and reviewed when desired. Detector Configuration The detector assembly cover provides easy access to the smoke sensor, its wiring connections, sample and exhaust tubes, and the smoke chamber itself. Air enters the detector's sensing chamber through a sampling tube (ordered separately) that extends into the duct and is directed back into the ventilation system through an exhaust tube (in­ cluded). The difference in air pressure between the two tubes pulls the sampled air through the sensing chamber. When a sufficient amount of smoke is detected in the sensing chamber, the detector initiates an alarm. Page 2 of 4 The sampling tube may be installed from either the duct side of the assembly or from inside the sensor compartment, as preferred by the installer. (The exhaust tube must be installed from the duct side.) Sampling tubes may be rotated in 45-degree increments so that air-holes can be aligned to allow the unit to be mounted at virtually any angle relative to the air flow. In installations where the duct smoke detector's controls and indica­ tors are hidden from view, a remote test station or an LEO indicator can be connected to the detector to provide these functions. Remote Test Stations Labor-saving Remote Test/Reset stations provide alarm testing from the convenience of a remote location. Tests can be performed quickly and safely -without having to climb to the roof. Magnetically­ operated and key-operated one-gang models are available. Signature SuperDuct detectors are also compatible with SIGA-LED remote alarm LED. Air velocity in the duct as low as 100 ft/min. maintains adequate air flow into the sensor smoke chamber through air holes in the air sampling tube and discharges through the exhaust tube. Su­ perDuct air sampling tubes must be installed with the inlet holes facing the airstream. Sampling tubes may be rotated in 45-degree increments so that air-holes can be aligned to allow the unit to be mounted in virtually any angle relative to the airflow. SuperDuct sensors are engineered to operate optimally under the harsh environmental conditions frequently found in HVAC duc­ twork. Nonetheless, before installing the detector, test the duct air velocity, temperature, and humidity to verify that it is within the operating range of the SuperDuct detector. Consult the SuperDuct installation sheet for details. Dimensions ,._ ______ 6.70"1(22.1cm) ------- ,._ ______ 6.15In{20,7em) ------- ,__ _____ 7.151n(19,7ctn) ------, 1.60,n (4.06cm) 22s,n (5.78 cm) 1.901n (4,63cm) 85001-0584 Issue 6 Assembly Sampling tube ----­ socket Exhaust tube socket Mounting Airflow Wiring Auxiliary equipment 1U~ 17 16 15 11 Page 3 of 4 -HVACduct #1 O sheet metal screw (2X) [1] No more than one remote test station or LED indicator can be connected to the detector at the same time. Wiring is unsupervised. Maximum wire resistance is 10 ohms per wire. Data In(+) Data !n (-) 0 0 0 0 ~ Power indicator Alarm indicator High-humidity environments Use the SD-PH Protective Housing when installing SuperDuct detectors in high-humidity environments. The SD-PH is a weather­ ized housing that prevents condensation on the device by insulat­ ing the detectors and providing circulated air from the monitored HVAC duct. The SD-PH also adds a layer of protection against physical damage to the unit. Hinged Cover Housing air tube Detector conduit holes The SD-PH is easy to install and service. The hinged and transpar­ ent cover provides ready access to the detector, while keeping its status indicators visible at all times. Note: The SD-PH Protective Housing is weatherized against out­ door air, but it is not intended for direct outdoor exposure. I Ft,____t: 1 I ·T" 1 - 2 .!1 • l i§ii§ii§l~i§li§li§I~ 14 13 12 11 10 9 8 7 _h ~ l AJm Te_!t = 11 DataO DataO j SD-TRK " SD-TRM [1) ut(-) ut (+) 85001-0584 lssue6 Detection & alarm since 1872 U.S. T 888 378 2329 F 866 503 3996 Canada Chubb Edwards T 519 376 2430 F 519 376 7258 Southeast Asia T : +65 6391 9300 F : +65 6391 9306 India T : +91 80 4344 2000 F : +91 80 4344 2050 Australia T +61392391200 F +61 3 92391299 Europe T+3227251120 F+3227218613 Latin America T 305 593 4301 F 305 593 4300 utcfireandsecurity.com @ 2010 UTC Fire & Security. All rights reserved. Page4of4 Specifications, detector Specifications, test stations Dimensions 8.70 x 5.45 x 1.90 inches Remote Test/Reset Stations provide alarm test, trouble (221 x 138 x 48 mm) indication, and reset capabmty from a remote loca- Wire size 14 to 22 AWG tioo. They include a one-gang plate, momentary SPST switch, red alarm LED, and terminal block. Magnet·1cally- Detection Photoelectric operated models (TRM) or key-operated models (TRK) method (light scattering principle) North American 1 -gang box Air velocity 100 to 4,000 ft/min and Compatible Standard 4-in square box, meets the required minimum electrical rating 1-1/2 inches deep, with air pressure differential boxes 1-gang cover Air pressure 0.005 to 1.00 inches of LED indicators -Alarm (red) differential water LED type Clear lens --~---·-·-- Sensitivity 0.79 to 2.46 %/ft Wire size 14 to 22 AWG obscuration Resistance per Alarm test 5 seconds wire 1 O Ohms, max. response time Current LED indicators Alarm (red), Power (green) requirements See contro!!er spec·1ficatlons Unsupervised and power-LED circuit Voltage: 3 Vdc, max. limited ratings Current: 30 mA, max. Common Quantity: 1 Switch ratings Voltage: 125 Vdc, max. alarm relay Type: Form C (SD-TAK) Current: 4 A, max. Ratings: 2.0 A at 30 Vdc Switch ratings Voltage: 200 Vdc, max. (resistive) Operating (SD-TRM) Current: 0.5 A, max. voltage 15.2 to 19.95 Vdc Compatible SuperDuct conventional Standby: 45 µA Alarm: 45 detectors two-wire and Signature duct Operating smoke detectors current µA Inrush: 1 mA Standalone -4°F to 158°F (-20°C to alarm: 18 mA Operating Temperature (UL): -4 to 158 environment 70°C} Humidity: 93% RH, 'F (-29 to 70 °C). noncondensing Operating Temperature (ULC): -4 to Storage -4 to 140 °F (-20 to 60 °C) environment 120 °F (-29 to 49 °C) temperature Relative humidity: 10 to Agency listings UL, ULC, MEA, CSFM 93%, noncondensing Agency UL, ULC, CSFM, FM, MEA listings Ordering Information Description Ship Wt., lb. {kg) Catalog Number SIGA-SD Intelligent SuperDuct Detector 2.4 11.1 I Accessories SD-TS 8-inch sampling tube 0.5 (0.2) SD-T18 18-inch sampling tube 1.5 (0.7) SD-T24 24-inch sampling tube 2.7 (1.2) SD-T36 36-inch sampling tube 3.0 (1.4) SD-T42 42-inch sampling tube 3.5 (1.6) SD-T60 6D-inch sampling tube 5.8 (2.6) SD-T78 78-inch sampling tube 7.5 (3.4) SD-T120 120-inch sampling tube 11.5 (5.2) SD-PH Protective housing for high humidity environments 5.5 (2.5) SIGA-LED Remote alarm LED 1.0 (0.5) SD-TRM Remote test station, magnetic 1 .0 (0.5) SD-TAK Remote test station, keyed 1.0 (0.5) SD-VTK Air velocity test kit (stoppers only, etc) 1.0 (0.5) SD-GSK Cover gasket kit 0.5 (0.2) _S~D=-M_A_G==----"-es_t_m_a~g~n_e_t k_it_~--------_____ 0_.5 (0.2) SIGA-SDPCB Replacement PCB/Signature sensor kit 1.0 (0.5) 85001-0584 Issue 6