Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DWG 396-7T; CT 00-16; POINSETTIA SHORES WATERS END INTERIOR RETROFIT; 01-29
CITY OF OCEANSIDE HIGHWAY 78 PACIFIC OCEAN PROJECT CITY OF VISTA ROA VICINITY MAP CITY OF ENCINITAS @ ------~ SCALE: NO SCALE NOTES: A SEPARATE CITY REVIEW AND APPROVAL IS REQUIRED FOR ANY PORTIONS OF THESE PLANS REQUIRING A BUILDING PERMIT. CITY APPROVAL OF THESE PLANS IS FOR LANDSCAPE PLANTING AND IRRIGATION ONLY. IT IS RECOMMENDED THAT A FULL WEED ABATEMENT PROGRAM BE PROVIDED TO REDUCE THE AMOUNT OF WEEDS PRIOR TO PLANTING. UPON COMPLETION OF ALL FINE GRADING WORK AND SOIL PREPARATION, PERFORM WEED CONTROL MEASURES AS FOLLOWS: A. IRRIGATE ALL AREAS DESIGN A TED TO BE PLANTED FOR A MINIMUM OF 10 MINUTES PER SETTING, TWO SETTINGS PER DAY FOR SEVEN DAYS TO GERMINATE ALL WEEDS SEED POSSIBLE. B. APPLY A CONTACT WEED KILLER AND ALLOW SUFFICIENT TIME TO OBTAIN COMPLETE KILL OF ALL WEEDS GERMINATED. C. REPEAT STEP A ABOVE. D. REPEAT STEP B ABOVE. PRIOR TO PROJECT COMPLETION: PLEASE PROVIDE ALL OF THE FOLLOWING CLOSE OUT DOCUMENTS. A. CERTIFICATE OF COMPLETION (P-25D FORM) B. MAINTENANCE SCHEDULES C. IRRIGATION SCHEDULES D. SOILS REPORT E. CERTIFICATION FOR CITY PROJECT RELEASE (P-25E FORM) F. IRRIGATION AUDIT G. HYDROZONE DIAGRAM REDUCED, LAMINATED, AND STORED WITH THE IRRIGATION CONTROLLER. LANDSCAPE DRAvVINGS FOR: CARLS BAI), CALIFORNIA 92011 DRAWING INDEX: SHc.f. I Ii (Le. I SHEET /\/UMBER SEOUENCF /\/UMBER PROJECT SITE PLAN/ HYDROZONE MAP TITLE SHEET )-/ ' I ' ' GENERAL NOTES T-2 2 SPECIF/CATION NO TFS T-3 -, ' v ------- ----SHEETS Ll-11, LP-11 /,RR/GA T/ON PLANS L/-1 TRU L/-12 4 15 PLANTING PLANS LP-7 TRU LP-12 16-27 ----------------- SHEETS Ll-12, LP----SHEETS Ll-9, LP-9 I ANDSCAl'E DETAILS DTL-1 TRU OTL-2 28-29 TOTAL NU/v/BE.R OF SHEETS 29 I SHEETS -SHEETS ll-7, LP-7 SHEETS ---:SHEETS Ll-5, LP-5 SHEETS Ll-6, LP-6 -SHEETS Ll-3, LP-3 SHEETS SHEETS ~SHEETS Ll-1, LP-1 THIS SHEET ~ (NTS) NOTE: ALL IRRIGATED LANDSCAPE AREAS TO RECEIVE POTABLE WATER. REFER TO SHEET Ll-1 TRU Ll-12 IRRIGATION PLAN FOR HYDROZONED LAYOUT AREAS. P.O.C.-(HOA) INTERIOR PARKWAY WJAL IRRIGATED LANDSCAPE AREA: 52,900 SQ. FEET. ZONE 1-LOW WATER USE HYDROZONE AREA: 52,900 SQ. FEET DI RT WATER EFFICIENT LANDSCAPE DECLARATION: I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL & WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WIT HOSE REGULATIONS AND THE LANDSCAPE MANUAL. I CERTIFY THAT THE PLAN IMll'D'iME:NlS ""'-"'"E GULA Tl NS TO PROVIDE EFFICIENT USE OF WATER. BY: SIGNED UNO R PHONE NO: ( REGISTRA Tl N NAL O PERJURY 60 ) 692 -1924 O: 2961 EXP/RATION DA TE: DECLARATION OF RESPONSIBLE CHARGE: DATE: 10-31-2026 I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER OF WORK FOR THIS PROJECT, THAT I HA VE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THIS PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD AND SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH AND QUALITY IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION PLAN, FIRE PROTECTION PLAN, AND ALL CONDITIONS OF APPROVAL RELATED TO LANDSCAPING. l BY: THE r"' LIGHTFOOT PIANNING GROUP JAMES L. 0 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (7601 692-1924 .lightlootpg.com SI DESIGN VCTURE PHONE NO: ( 6 REGISTRATION 0: ) 692 -1924 ---'2_9_6_1 ___ EXP/RAT/ON DA TE: DA TE: 10-31-2026 BACKFLOW PREVENTER TESTING: ALL IRRIGATION BACKFLOW PREVENTERS SHALL BE TESTED BY A CERTIFIED TESTER AND RESULTS MUST BE GIVEN TO THE CITY AND THE CARLSBAD MUNICIPAL WATER DISTRICT. PIPE BETWEEN THE METER AND BACKFLOW PREVENTER SHALL BE "SCHEDULE K HARD COPPER". APPROVED CONTRACT BACKFLOW TESTERS CAN BE FOUND BY CALLING (760) 438-2722. INSPECTION PROCEDURES: INSPECTION OF THE PROJECT SHALL BE PERFORMED BY THE LANDSCAPE ARCHITECT OF WORK, OR THE LANDSCAPE ARCHITECT OF WORK'S DESIGNATED AGENT. REFER TO THE SPECIFICATIONS FOR THE SCHEDULE OF REQUIRED INSPECTIONS AND REQUIRED SUBMITTALS. FOLLOWING COMPLETION OF THE WORK, THE LANDSCAPE ARCHITECT OF THE WORK WILL CERTIFY THAT THE INSTALLATION HAS BEEN COMPLETED BY SUBMITTING THE "CERTIFICATION OF COMPLETION" FORM. E-MAIL THE FORM TO: glen@trib-la.com. TO MAKE A REQUEST FOR A FINAL LANDSCAPE INSPECTION BY THE CITY, CALL (760) 434-9300. PRIOR TO BEGINNING LANDSCAPE WORK: THE CONTRACTOR SHALL CONTACT THE DESIGNER OF WORK PRIOR TO BEGINNING LANDSCAPE WORK AND THE DESIGNER OF WORK SHALL REVIEW THE PROJECT UTILITY LOCATIONS AND REVISE PLANS ACCORDINGLY TO FULLY SCREEN ALL UTILITIES FROM VIEW AND PROTECT ALL UTILITIES (ABOVE & BELOW GRADE) FROM INVASIVE PLANT GROWTH AND ROOTS. IRRIGATION AS-BUil TS: IRRIGATION AS-BUILT PLANS ARE REQUIRED TO BE SUBMITTED TO THE CITY AND SHALL BE PREPARED AS REQUIRED BY THE ENGINEERING AND PLANNING DIVISIONS. THE FINAL PLANS SHOULD BE PREPARED BY THE LANDSCAPE ARCHITECT FROM DIMENSIONS PROVIDED BY THE CONTRACTOR. FINAL AS-BUil T PLANS WILL BE REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY PRIOR TO RELEASE OF SECURITIES. DIAL TOLL FREE 1 -800-422-4133 AT LEAST 1WO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA APPROVED FO1R l,RRIGATION AND PLAN 1ING ONLY, INCLUDING 17RECISE LOCATION OF PLAN IING /\RE/\. RCE __ _ lXP, ___ _ DATE REVIE'w'ED BY, T -1 INSPECTOR DATE REFERENCE DRAWINGS: 2237 FARADAY AVENUE SUITE120 r---::~=:::;:::-----, 1---_ -_ -_ -_t+--_ -_ -_ -_ t+ -_ -_ -~~~~~~~~~~~~~~~~~~~~~~~~~~~~~_j~~~~~__[~~~~.l~~~~_j~,=~~_J--1 l---+--+----------------1----t---t----t-----1 I SHE1 ET 11 CITY OF CAR LS BAD _ PLANNING DIVISION ~L=A=N==D=sc=A'-'P==E=· :::IM::::P:::R:::O:::V:::E:::M:::E:::N~T=P:::L==A~N==s=F~O:::R::::======::; CARLSBAD, CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE I /08/26 6/16/26 5/05/26 DESIGNED BY: _E-E __ DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.: J. TAYLOR JOB NO.: 1765.01.1 POINSETTIA PROPERTIES (WATERS £ND) TITL[ SHEET 1-----f----l-----------------t-----t---t---i----i ~=='=:::;:;:==;-~=======::;-;::::-~=--==-=--=--=--=--:::::_= OWN BY: _,E~E -~ PROJECT NO. DRAWING NO. DATE INITIAL ENGINEER OF WORK Fxpirotion Date:10/31 /26 RFVISIDN rJFSCRIPTIDN DATE INITIAL OTHER APPROVAL CHKD BY: ,cJT,___ LPC2026-0014, RVWD BY: CT000016 DATE INITIAL CrrY APPROVAL 396-?T r CITY OF CARLSBAD PROJECT NOTES GENERAL NOTES 1. SLOPE REVEGETATION/EROSION CONTROL a. Construction Schedule 1. Prior to start of grading, the applicant or applicant's agent shall obtain City approval of a construction schedule and/or exhibit outlining the timing of the slope planting and irrigation. 2. Special consideration shall be given to water and electrical services. 3. Irrigation and planting shall take place as grading progresses. 4. The schedule shall show timing of construction of free standing, retaining and crib walls immediately after rough grading at each location is achieved. 5. Water service (Point of Connection) installation, temporary or permanent, shall be in place to coincide with planting timing specified in Section E. 3-1. 6. Planting and irrigation for the slope areas shall be completely installed, as shown on the approved plans, within 30 days after the irrigation installation first commences. 7. Where planting occurs on slopes 6: 1 or steeper and slopes are to receive a hydroseed mix, contractor shall spray hydroseed mix and then cover the slopes with a City of Carlsbad approved Erosion Control Fabric. Refer to Specifications. Where the planting occurs on slopes 6:1 and steeper, and a hydroseed is not used, contractor shall install a City of Carlsbad approved reinforced straw mat. 2. LETTER OF CERTIFICATION (RELEASE OF BONDS) a. Prior to release of bonds, the licensed designer of record on the project shall submit a letter to the City Engineer certifying that he or she has inspected the work and that the project complies with the following conditions: 1. Has been maintained in substantial conformance. 2. Is growing in a healthy and thriving condition. 3. All plantings required under section IV.e of this manual have been established as an effective surface erosion control. 4. There is no evidence of excessive runoff from the irrigation system causing a soil erosion problem. 3. AS BUILTS a. As-builts for all projects (bonded and non-bonded, public and private) are required to be submitted. Submittal of as-built plans shall be as required by the Engineering and Planning Departments. b. Final as-built plans shall be drafted clearly to the satisfaction of the City, and the original bond shall be submitted to the City for their keeping. c. Final irrigation as-built plans will be required to be reviewed and approved by the City and final bond will be required to be approved and signed by the City prior to release of securities. 4. All building pad and street areas that are graded and remain vacant or undeveloped for a period of more than 6 months after the grading operation is completed shall be seeded to reduce erosion and visual impacts. If grading is phased, the six month time period shall start at the completion of each individual grading phase. 5. All unpaved areas shall be revegetated according to the approved landscape plans as as soon as possible after grading. 6. To reduce the visual impacts of manufactured slopes and roadway cuts, all cut and fill slopes shall be landform-graded, contoured, and heavily screened by landscaping. All planted slopes shall be watered with a complete irrigation system using low precipitation-rate sprinkler heads to stabilize exposed slopes and curtail visual impacts associated with possible erosion. 7. This plan pertains to Landscape items only, see Civil Plans for Grading and Erosion Control 8. MAINTENANCE: The Contractor or Owner is required to fully maintain all permanent slope landscaping and all non-mitigation landscape areas during ninety day ( 90 day) establishment period prior to City acceptance of all improvements in those areas. All landscape areas shall be permanently maintained by the Owner. 9. The Contractor shall have California native plant habitat restoration experience and shall provide a resume, complete with list of successful projects and contact information for Habitat Restoration Specialists and project Owners that can verify project experience. Prior habitat restoration experience shall include irrigation, planting, hydroseeding, weeding and maintenance under the monitoring and direction of a Habitat Restoration Specialist. Native plant species knowledge is essential for successful establishment, weed removal and long-term maintenance. ADDITIONAL NOTES 1. All construction and installation of landscape items are subject to requirements of the City of Carlsbad Landscape Manual and Environmental Documents. The contractor must notify the consulting City the Landscape Architect of Record for inspections, 48 hours ( 2 working days) minimum, prior to starting construction. 2. The Landscape Contractor is responsible for obtaining all permits necessary for installation prior to beginning work. This includes all building permits prior to commencing wall construction. 3. The Contractor is responsible for knowing all site conditions and all underground utilities, pipes and structures, and shall take sole responsibility for replacement costs incurred due to damage during construction. 4. The Landscape or Irrigation Contractor is to verify existing PSI at the job site prior to installing the landscape irrigation system. Discrepancies between the design pressures shown on the plan and existing static pressures shall be reported to the project Landscape Architect (760-692-1924). 5. The Contractor shall not willfully proceed with construction when it is obvious that discrepancies exist between this plan and actual site conditions, and assumes responsibility that any discrepancies are brought to the attention of the owner's representative. The Contractor shall bear the cost of necessary revisions due to failure to give such notification, and no change in contract price will be allowed for actual or claimed discrepancy between existing conditions and those shown on plan. 6. 48 hours (2 working days), prior to beginning construction, the Contractor's on-site supervisor shall meet with the owner's representative for a pre-construction site meeting. During construction, the owner's representative shall be available for site consultation. In case of any questions, the Contractor shall notify the owner's representative for clarification. Any work not meeting the approval of the Owner or his representative shall be corrected at the Contractor's expense. 7. All property and lot lines shall be verified and marked in an obvious manner 8. All reduced pressure backflow preventors and pressure vacuum breaker assemblies shall be tested by a City approved certified tester after installation, relocation, or repairs. The Developer/Owner is responsible for supplying a copy of the test results to the City Public Works Department. 9. Approved landscape plans and specifications, and the City of Carlsbad Landscape Manual shall be at the job site location at all times. 10. Ground cover areas shall have a maximum design slope of2:1. 11. Contractor shall provide certification by manufacturer that system controller, sensors, and valves are all installed per manufacturer specifications. 12. For details not referenced or shown on these plans, please refer to manufacturer's 13. All engineering information on these plans are for reference only. 14. All irrigation backflow preventers shall be tested by a certified tester and results must be given to the Carlsbad Municipal Water District. Contact the Carlsbad Municipal Water District for a list of approved certified backflow testers. Pipe between the meter and backflow preventer shall be per specifications and notes in Detail Drawing No. W-12. 15. Water sevice (point of connection) installation, temporary or permanent, shall be in place to coincide with planting timing specified in section E.3-1. 16. Prior to occupancy and/or security release the landscape architect of work shall review/inspect the project and provide a certification letter for release of securities, and an irrigation schedule and landscape maintenance schedule as required by the city water ordinance. THE PLANTING NOTES 1. Plant material locations shown are diagrammatic and may be subject to change in the field by the Landscape Architect. All easement areas to be verified in the field and all planting restrictions shall be conformed to by landscape contractor. 2. Refer to the Landscape Manual City of Carlsbad Policies and Requirements, February 2016. 3. Plant count is for the convenience of the Contractor. In case of discrepancies, the plan symbols shall govern. For Mitigation Areas, counts shall be per Habitat Restoration Specialist. 4. Each group of plant materials and seed mix delivered to the site shall be clearly labeled as to species, variety and nursery source. Any seed mix or native plant material for Mitigation Areas are subject to rejection by the Landscape Architect and Habitat Restoration Specialist. 5. The size of the plants will correspond with that normally expected for species and variety of commercially available nursery stock, or as specified in the drawings. The minimum acceptable size of all plants, measured before pruning with the branches in normal position, shall conform with the measurements, if any, specified on the drawings in the list of plants to be furnished. Plants larger in size that specified may be used with the approval of the City Landscape Inspector, but the use of larger plants will make no change in contract price. 6. All plants not conforming to the requirements herein specified, shall be considered defective, and such plants, whether in place or not, shall be marked as rejected and immediately removed from the site of the work and replaced with new plants at the Contractor's expense. The plants shall be of the species, variety, size and condition specified on the drawings. Under no condition will there be any substitution of plants or sizes for those listed on these plans, except with the expressed written consent of the Project Landscape Architect and the City Landscape Inspector. 7. The backfill mix for use around the rootball of container grown trees, shrubs, and groundcover shall be per specifications. Refer to sheet 9. Contractor to provide new soils report, as comprehensive as preliminary report, after rough grading, soil samples shall be taken from enough locations on the site to represent an adequate cross section of conditions. Soil test shall be performed by a soil testing laboratory (pre-approved by the City). The test shall indicate but not be limited to the following: a. organic matter content b. N,P,K c. pH d.EC e. soil texture (silt, clay, sand) f. recommendations for amendments, leaching, and maintenance fertilizations. The results and recommendations of the soil testing laboratory shall be submitted to and approved by the City. The approved recommendations for amendments and backfill shall be incorporated into the landscape plans prior to the start of construction and shall become part of the approved plans. 8. All landscape planting to be installed in accordance with the Landscape Manual City of Carlsbad Policies and Requirements, February 2016. 9. Erosion control measures are per Civil Engineer's Grading Plan. 10. A 1 quart physical sample of organic mulch and composted organic amendment shall be provided to the Landscape Architect for review prior to bulk delivery. 11. The contractor shall provide material submittals, catalog cut sheets, shop drawings or samples of all material, equipment and assemblies used to complete the contract. Submit three copies for landscape architect review. ADDITIONAL NOTES Erosion Control measures for slopes 6: 1 or steeper requiring erosion control measures as specified herin shall be treated with one or more of the following planting standards: a. City of Carlsbad Standard 1 -Cover Crop/Reinforced Straw Matting: Cover crop shall be a seed mix typically made up of quick germinating and fast covering grasses, clovers, and/or wild flowers. Submit specific seed mix to for City approval prior to application. The cover crop shall be applied at a rate and manner sufficient to provide 90% coverage within thirty (30) days. Reinforced straw matting shall be per specifications, and as approved by the city and staked to slope as recommended by the manufacturer. Reinforced straw matting shall be required when planting occurs between August 15 and April 15. The cover crop and/or reinforced straw mat shall be used the remainder of the year. b. City of Carlsbad Standard #2 -Ground Cover One hundred (100%) percent of the area shall be planted with a ground cover known to have excellent soil binding characteristics (planted from a minimum size of flatted material and spaced to provide full coverage within one year). c. City of Carlsbad Standard #3 -Low Shrubs Low Spreading woody shrubs (planted from a minimum of 1 gallon containers shall cover a minimum of seventy (70%) of the slope face (at mature size). d. City of Carlsbad Standard #4 -Trees and or large Shrubs Trees and /or large shrubs shall be (planted from a minimum of 1 gallon containers) at a minimum rate of one (1) per two hundred (200) square feet. 9. Erosion control measures for Slopes -6:1 or steeper and: a. 3' or less in vertical height and are adjacent to public walks or streets require at a minimum City of Carlsbad Standard #1. b. 3' to 8' in vertical height required City of Carlsbad Standards #1 (erosion control matting shall be installed in lieu of a cover crop), #2, #3. c. In excess of 8' in vertical height require City of Carlsbad Standards #1(erosion control matting shall be installed in lieu of a cover crop), #2, #3 and #4. 10. Areas graded flatter than 6:1 require City of Carlsbad standard #1 (cover crop) when they have one or more of the following conditions: a. Sheet graded pads not scheduled for improvements within 6 months of completion of rough grading. b. A potential erosion problem as determined by the City. c. Identified by the City as highly visible areas to the public or have special conditions that warrant immediate treatment. NON IRRIGATED FLAT PADS, SLOPE HYDROSEED AND IRRIGATED AND PLANTED AREAS TO BE INSTALLED PER PLANS. ADDITIONAL EROSION CONTROL DEVICES SHALL BE INSTALLED PER THE CIVIL ENGINEERS GRADING PLANS. SUPPLEMENTAL WATER SHALL BE APPLIED AS NECESSARY TO ACHIEVE 90% VEGETATION COVER TO LANDSCAPED SLOPES. AS PER CITY GUIDELINES AND REGULATIONS, SECURITY BOND RELEASE SHALL BE SUBJECT TO ALL CITY APPLICABLE GUIDELINES, AND REQUIREMENTS. TREE SELECTION A. Trees shall have a straight trunk with balanced crown structure. B. Trees shall have a single, strong central leader. double (co-dominant) leaders will not be accepted. C. Tree bark shall not be discolored, sunken, or swollen, cuts or scrapes that measure 1/4 of the tree circumference will not be accepted. D Trees showing insect galleries, sun scald, or frost damage will not be accepted. E. The caliper of the tree shall be in proportion to the rootball. F. No branches shall extend from the trunk with greater than a 45 degree vertical angle (angle less than 45 degrees). G. No tree with circling, j-hook or girdling roots which wrap around the trunk, will be accepted. H. Trees shall be free of crossing branches and branches growing too close together. I. Freshly pruned trees shall not be accepted for installation. The quality of all trees and their intended location in the field shall be approved by the owner representative, prior to planting for the project and public right-of-way property Standards for palm selections 1. All palms shall be specimen quality, free of insect pests, sun scorch leaf spot, diamond scale or any other disease or pest. 2. Palms shall be acclimated to the site per grower specifications prior to planting. allow as many months as necessary, per grower, to achieve climate adaptation. 3. 4. Palms shall be of matched height, naturally. do not bury rootball deeper, in order to match heights. IRRIGATION NOTES 1. This irrigation design is diagrammatic. All piping, valves, and all other irrigation devices shown within paved areas are for design clarification only and shall be installed in planting areas wherever possible. All irrigation work shall be installed to avoid any conflicts between the irrigation system, planting material and other architectural features. 2. Do not willfully install the sprinkler system as shown on the drawings when it is obvious in the field that obstructions, grade differences or differences in area dimensions exist that may not have been considered in the engineering of the site. Such obstructions or differences should be brought to the attention of the owner's authorized representative. In the event this notification is not performed, the irrigation contractor shall take full responsibility for any revisions necessary. 3. It is the responsibility of the Irrigation Contractor to familiarize himself with the landscape improvement plans, including all grade differences, the location of walls, retaining walls, paving and similar structures. He shall coordinate his work with the general contractor and all other sub-contractors for the location and the installation of pipe sleeves through walls, under roadways, paving, structures, and all other hardscape areas. 4. Due to the scale of these drawings, it is not possible to indicate all offsets, fittings, sleeves, and other items which may be required. The contractor shall carefully investigate the structural and finished conditions affecting all of his work and plan his work accordingly furnishing such fittings, and material, as may be required to meet such conditions. These drawings are diagrammatic and indicative of the work to be installed. 5. Each controller shall have RAIN SHUT OFF AND WEATHER SENSING TECHNOLOGY. 6. Controller locations shall be as shown on the drawings. 7. Splicing of 24 volt wires will not be permitted except in valve boxes. Leave a 24" coil of excess wire at each splice and at 100 feet on center along wire run. Tape wire in bundles at 10 feet on center. No splicing is permitted inside sleeves. 8. The irrigation system design is based on a minimum operating pressure of 40 PSI. The Irrigation Contractor shall verify the static water pressure (PSI) prior to construction and report any difference between the water pressure indicated on the drawings and the actual pressure reading at the irrigation point of connection to the owner's authorized representative and the Project Landscape Architect. 9. All irrigation equipment is to be installed in accordance with the standards and specifications of the City of C<1rlsbad Landscape Manual. 10. The Irrigation Contractor shall notify the respective jurisdictions for inspection and testing of the installed backflow prevention device and pressure mainlines. Test mains for 4 hours @ 125 PSI and obtain City Inspectors' approval of test prior to backfilling trenches. Contractor to verify which jurisdictions are to be notified. 11. Install a spare control wire of a different color along the entire main line. Loop 36" excess wire into each single valve box and into one valve box in each group of valves. 12. Install valve boxes 12" from and perpendicular to walk, curb, walls, fences or other landscape feature. At multiple valve box groups, each box shall be an equal distance from hardscape, or planting area, and all boxes shall be 6" apart. The short side of the valve box shall be parallel to hardscape, walls, fences, etc. 13. All heads & drip emitters are to be installed a minimum of 12" from fences, walls, or structures. 14. All irrigation heads within the right-of-way and within 1 O' of any path, walk, or pedestrian areas shall be pop-up heads. 15. All sprinkler heads shall be set perpendicular to the finish grade of the area to be irrigated unless otherwise designated on the plans. 16. Sprinklers where low head drainage occurs shall be fitted with a King Bros. CV series check valve, or equal, in lieu of schedule 80 coupling. 17. The Irrigation Contractor shall flush and adjust all sprinkler heads for optimum performance and to prevent overspray onto walks, roadways and/or buildings as much as possible. This shall include but not be limited to: selecting the best degree of arc to fit the existing site conditions, the inclusion of pressure compensating fittings or flow reduction devices, throttling the flow control at each valve to obtain the optimum operating pressure, and coverage for each system. All systems shall operate at the pressures specified in the irrigation legend. 18. The Irrigation Contractor shall install all irrigation lines and controller wires in sleeving that pass under paving. Sleeves shall be 2X pipe size diameter, and extend 12" minimum past paving or hardscape. End of sleeve shall be marked with a round valve box -see plan legends. For clarity, all sleeving is not shown on this plan. Sleeving shall be as follows: Schedule 80 PVC sleeving applications for pipe sleeves under roadways and vehicular paving 6" or less in diameter -36" cover Greater than 6" in diameter -48" cover Schedule 40 PVC sleeving applications for pipe sleeves under architectural paving (non-roadyway uses) Less than 3" in diamter -18" cover 3" -5-1 /2" in diameter -24" cover 6" or greater in diameter -36" cover 19. To use quick coupling valves when master valve is closed: wire the master valve to an unassigned controller station and manually start the station for the required time period. If no station is available, manually bleed the master valve to operate the quick coupler. 20. Install all irrigation lines below (perpendicular) to brow ditches. 21. If static pressure is 80 PSI or greater, install pressure regulator at POC as required by City. 22. Contractor shall provide and install mylar/metalic pipe detection tape over all irrigation mainline and sleeve crossings installed within public right-of way or areas of regular vehicular traffic. 23. The landscape contractor shall provide material submittals, catalog cut sheets, shop drawings or samples of all material, equipment and assemblies used to complete the contract. Submit three (3) copies for landscape architect review prior to installation. 24. All graded portions of the site that are not permanently landscaped and not scheduled for improvements within 6 months of completion of rough grading shall be temporarily irrigated and planted as approved by the City of Carlsbad. Otherwise, all areas shall receive complete coverage with automatic sprinkler irrigation systems. Any sprinkler system within 1 O' of hardscape, City right-of-way and any other areas where significant pedestrian traffic may occur shall be below grade. ' .DIGA -~RT _..,. ................ T.M. DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA T-2 APPROVED FOR IRR:GATION AND P1 ANTI NC; ONLY, INCLUDINC; PRF Cl St LOCATION OF rLANTING AREA. palm fertilizer shall be used to supply micronutrients .. 1;os;2s ,-7--r---~----------T---r--r---r--r;::::====:;';::====================:::::::==:::::::====;-1 6/1s;2s [s'HEE1 CITY OF CARLSBAD 5/05/26 1----+----+-----------------+---l----+---+-----t L..2._j PlANNING DIVISION r----~~~~~;--;----,-~~:::;:::---:t-1 _-_-_-+-I_-_--ti_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-.....,i--_-_-+t _-_-_i._1 _-_-_-t_-_---II ~==-=============:I I .,, LIGHTFOOT PIANNING GROUP 2237 FARADAY A VENUE SUITE 120 CARLSBAD, CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE I // As Bu T I I // t,-I-IOSCAP£ LANDSCAPE IMPROVEMENT PLANS FOR: '<.,<:) >'/'.y:=_YL-,...:::1!&~ 41'(' POINSETTIA PROPERTIES f Js /~;/ 1 1 "· "'1-,,~ _.,,. (WATERS £ND) ::i :f1 IIJ I -~ ':..\ GENERAL NOTES PLANNING RCE __ _ [XP, ___ _ DATE REV'.EwEJ 3Y, DESIGNED BY: ~EE~--DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED INSPECTOR DATE PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 ✓ .,,n,re IAPPR~ ~ I 1, 10/31/26 * ~A , ./ ,f In {~IA ;'\ /,v•n .. wcl ,LJ,c)te / t------+--+----------------+----+--+----+----f -~~~-/V\.~''--",,-,..~~-~~---t \u L.A.£ -7 /'/ r/. ~ l----+---1--------------------+--+---+---+----I .;.P:::LA::N:::Nl:::NG::::::::::;:==:::;-;:========~==D=AT=E==;· ,'-1, -0,-<-'-r 0FcAL~ =~ ~E=E __ DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: =JT __ ENGINEER OF WORK Expiration [)oh~:10/31/26 REVISION rJFSCRIPTION OTHER APPROVAL CITY APPROVAL RVWO BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING ND. 396-7T II. IRRIGATION A. SCOPE OF WORK 1. This work shall consist of the installation of a complete automatic irrigation system as shown on the plans. Bid price shall include all labor. materio!s, tools and equipment costs as well as any other expenses necessary for the completion of this project. B. IRRIGATION DESIGN 1. The pion is diagrammatic. Refer to notes, details, and legends to verify locations of irrigation equipment. 2. Contractor shall carefully check and verify conditions on-site and be familiar with the location and details of on-site connections of water and power sources. 3. Discrepancies between the plan elements and/or site conditions must be brought to the attention of the Owner's Representative during bidding and prior to proceeding with any work. Failure to do so will result in responsibility by the Contractor for any and all revisions that result therefrom. C. MATERIALS 1, All materials shall conform to the local ordinances governing irrigation equipment. 2. All materials and equipment shall be new, and shall conform to the standards of specification by the manufacturer. 3. Under any circumstances, no substitution of equipment will be allowed without prior written approval of the Landscape Architect and City Inspector. Contractor shall submit data to support claims of equal performance. Standards of performance of specified materials and equipment shall be used as a performance standard; substitute material must match specified material. • 4. Equipment and materials shall be as called out on the plan legend. D. LAYOUT 1. Prior to installation, Contractor shall mark-out, with chalk or equal, all pressure supply lines and laterals, indicate the locations of irrigation heads and valve 2. Layout shal! be such that no hindrance or interference with planting or hardscope construction occurs. 3. Owner's Representative shall approve layout and verify the location of control clocks prior to installation. E. INSTALLATION 1. Irrigation heads and risers shall be installed perpendicular to finish grade and/or manufactured slopes and checked for adequate coverage prior to permanent 2. Flush all lines prior to installation of sprinkler heads. 3. Spacing of heads shall not exceed the radius indicated in the irrigation legend. 4. Thoroughly flush all (lateral) lines prior to installation of sprinkler heads and/or drip emitters. After installation of drip emitters, flush laterals a second time before 6. Minimum depth of drip line shall be 3" to 4" inches for shrub areas, and 6" for turf areas. Install lines from planter edges maximum of 6" for shrub and 4" for turf. 7. Provide support for dripline and install soil staples 6' to 1 o• feet O.C. or as needed to secure lines and limit movement. 8. Overlap drip service sections, or install drip line above PVC headers to insure complete irrigation coverage being served by drip irrigation. F. TESTING 1. PRESSURE TESTS a. All pressure mains shall be capped and tested at a hydrostatic pressure of 150 p.s.i. for a period of four (4) hours and prove water-tight, prior to installing remote control valves. Any leaky fittings, joints and pipe shall be replaced and the line b. Lateral lines shall be capped and tested at the design pressure, at the last head, for three (3) hours, and prove water-tight, prior to installation of sprinkler heads. Any leaky valves. joints, fittings or pipe shall be replaced and the line retested. c. All pressure tests shall be performed in the presence of the Owner's Representative and City Landscape Inspector. d. Contractor shall provide all equipment necessary to conduct hydrostatic e. Contractor shall notify City Inspector 48 hours prior to hydrostatic testing. 2. Coverage Test a. When system is complete, Contractor shall perform a coverage test to determine that coverage is adequate and complete. b. Adjustments shall be mode by the Contractor to compensate for site conditions and variations in grade: {1) Heads shall be adjusted in height and alignment ofter planting is completed and prior to hydroseeding to ensure adequate coverage and that spray stream clears adjacent plant material. G. CONTROLLER SYSTEM 1. Controller shall be a solid state microprocessor based unit providing for manual or completely automatic function. a. Each station shall be capable of programming from 1-59 minutes and shall operate a minimum of one 24 VAC remote valve per station. b. • Controller shall have capacity for everyday, every other, or every third day programming and shall indicate the days watering occurs as well as indicating if watering occurs on the current day. c. Controller shall hove 4 separate start times per day, each individual start time shall be programmable at any time of day. d. Irrigation contr-oller shall be equipped witfl rain shut-off devices (weather based system or soil moisture detection system). 2. WIRING a. b. Control interconnect to be compatable with Roinbird irrigation equipment. 24 volt wires shall be used to operate the system. capping and pressurizing PVC lines. c. 5. Install sub-surface drip line per manufacturer's guidelines. Provide PVC supply lateral d. Splicing of 24 volt wires will not be permitted except in valve boxes. Leave o 24" coil of excess wire at each splice and at 100 feet on center along wire run/ and in change in direction. to PVC drip supply heoder. Use CL. 200 PVC crs drip exhcrust hecrders. e. Provide spore common and spare conductors. f. Tape bundles at 10 feet on center. g. No splicing is permitted inside sleeve. h. Wiring under hardscape, flatwork or vehicular ways shall be placed in pvc conduit and appropriate pvc pipe sleeve. i. All wire splices and connections shall be made with Rainbird 3M DBR/Y-6 splice kits for oB electrical wire connections. 3. Contractor shall conduct a pre-construction meeting with authorized Roinbird representative to review proper irrigation component installation .. H. FINAL ACCEPTANCE 1. Contractor shall demonstrate to Owner the operation of each system and piece of equipment. 2. Contractor shall provide all manufacturer's data for all equipment. 3. Contractor shall provide an 'as built' plan depicting the actual locations of lines, heads, valves and controlling systems. Each valve for each controller will be clearly shown and its station number indicated. 4. Contractor shall provide copies of each controller program, keys to the enclosure, and any special tools delivered as a stock accessory to any of the equipment. 5. Maintenance period shall not commence unt11 the requirements of this subsection have been fulfilled to the satisfaction and acceptance of the Owner. I. SUBMITT ALS 1. Contractor shall submit 3 copies of manufacturer cut sheets for all irrigation materials for review by the landscape architect. 2. Contractor shall review each submittal package for project application and conformance. Each submittal shall be stamped by the contractor certifying said review. J. GU ARAN TEE Contractor shall guarantee that the entire irrigation system is free from defects and workmanship, for a period of one year; ordinary wear and tear. unusual abuse, or neglect excepted. K. MAINTENANCE 1. OPERATION a. Contractor shall adjust his watering schedule equal to the application rote each area is capable of receiving, based on topography, sol! type, plant material, season and weather factors. Owner's Representative shall be given a key to controller and nstructions on how to turn off system in case of emergency. b. Periodically (a minimum of once a month) Contractor shall check all systems for proper operation and coverage. All heads are to be adjusted as necessary for unimpeded coverage. Adjust outlets of distribution tubing as required for growth of plant material. Observe the site regularly for puddling and run-off. Change length and/or frequency of the irrigation cycle to eliminate any problems. c. Check filter mesh condition within five to seven days of initial operation. If clean, check again in 30 days. Check condition of filter until a regular maintenance interval can be established for each site-specific system. d. The lines shalt be flushed periodically and whenever repairs hove been done on the system. If water quality is adequate, perform flushing at least once a month for 30 to 60 seconds. e. Monitor and maintain optimum operating pressures throughout the system. f. In Morch, all valve boxes shall be checked for soil invasion, cleaned out and new grove! replaced as noted in original specifications. g. All screens in backflow preventer strainers shall be checked and cleaned at least three (3) times per year or as often as necessary. h. Contractor shall utilize a repeat cycle on controller to eliminate excessive run-off. i. To insure minimal obstruction of irrigation spray patterns, Contractor will be responsible for trimming and making necessary adjustments to riser height as plant material growth rates indicate. j. All systems shall be personally observed by the Contractor during operation cycle at feast once per month to verify effectiveness of sprinkler operation. k. Contractor shal! throttle down valves enough to prevent useless fogging. allowing droplets for effective watering. I. Hours of scheduled operation will be programmed to minimize disease occurrence of plant material and reduce possible nuisance from sprinkler operation to pedestrians or vehicles. To prevent leaf burn of many plant species, do not operate the irrigation system during warm daylight hours, generally between 9: 00 a.m. and 5: 00 p.m. 2. MAINTENANCE a. Any repairs made by the Contractor will be in accordance with the original details or as directed by Owner's Representative. b. Repairs to irrigation system caused by conditions under which the Contractor does not have any direct control shall be paid for by the Owner as extra work. Such repairs are those caused by vandalism, normal wear and tear, storm damage {acts of God), or by other parties. It shall be the Contractor's responsibility to report such conditions immediately to Owner's Representative. c. Contractor shall make minor repairs under this contract. Minor repair shall be defined as an occasional repair such as a broken riser, which con be repaired easily without the need of a specialist. d. Malfunctions of any nature which □ re deemed to be the fault of materials or workmanship still covered under original installation guarantee shall be reported immediately to the Owner's Representative. e. Contractor shall furnish his own hoses, nozzles, sprays, and controller keys as required. f. Any damages to system caused by Contractor's operations shall be repaired without charge to the Owner. Repairs shall be made within one watering period. g. It will not be the responsibility of the Contractor to pay for heads requiring placement, but he will be responsible for the labor involved. Heads shall be of the exact type as previously installed. Substitution will be allowed only with prior approval of City. L. ADDITIONAL WATER LINE NOTES 1. SEP ARA llON BETWEEN WATER, SEWER, RECLAIMED WATER, AND OTHER UNDERGROUND UTILITIES Horizontal and vertical separation of water, reclaimed water, and sewer mains shall adhere to State of California Department of Environmental Health "Criteria far the Separation of Water Mains and Sanitary Sewers." a. Horizontal Separation: Ten (10') foot minimum separation between water, reclaimed water, and sewer mains shall be maintained. Any special situation requiring less separation will require District approval. b. Vertical Separation: Twelve (12n) inches minimum separation between water, reclaimed water, and sewer shall be maintained at all crossings, all crossing should be at 90 degree angles horizontally. Normally, water, reclaimed water. and sewer shall be located horizontally from the streets finish grade surface in the order of the higher quality, i.e., water shall be above reclaimed, reclaimed above sanitary sewer. Ill. LANDSCAPE PLANTING A. SCOPE OF WORK 1. This work shall consist of performance of soil preparation, planting and hydroseeding of those materials called out on the plans and installation of material per the details depicted on the plans. Bld price for this work shall include all labor, materials, tool and equipment costs as well as any other appurtenances necessary far the completion of this project. B. PLAN 1. The pion is diagrammatic. All plant material locations shown are approximate. Plant symbols take precedence over quantities. C. MATERIALS 1. PLANTS a. All plants shall be healthy, of normal growth, well rooted and free of diseases and pests. Quality and size shall conform to the state of California Grading Code of nursery stock, number one grade. b. Plant material shall not be root-bound. Owner reserves the right to reject any and oil material found to be defective. Defective material shall be removed from site and replaced with acceptable mater[al at Contractor's expense. c. Contractor shat! be responsible for damage to plant material due to negligence or irrigation system failure during construction or during the maintenance period. 2. SEED a. All seed is to be delivered to the job site unmixed and in separate sealed containers. Each sealed container shall bear the seed suppliers tags indicating the container weight, seed type, purity and germination. b. All seed shall be labeled according to State and Federal Seed Laws. c. A sample of each seed type shall be drawn and held for testing before seeding operations. If any discrepancy between specifications and germination material is discovered, Contractor shall pay for seed tests by Ransom Labs (805) 684-3427, and shall replace seeded area with specified mix. D. SOIL PREPARATION 1. Initially cross rip to a depth of 10-12 inches ond thoroughly leach.Then apply recommended materials and rototill a minimum of two directions, to a depth of 4-6inches aster soil preparation, but prior to planting, irrigate with overhead irrigation so that o minimum of 4-6 inches of quality water passes through the soil profile, beyond the root zone. Drainage is critical. Material recommended per 1000 square feet 150 lbs. Gro-Power Plus w/M 3 cu. yd of nitrolized shavings or good quality compost. 2. Backfill mix and amendments shall be as specified from soil tests. All backfill and amendments shall use native soil as a mix base. For bid purposes use: 70% native on site soil, by volume 30% nitrolized shavings or good quality compost 12 lbs. Gro-Power Plus w/M Gro-Power Pfanting Tablets for extended feed/conditioning Dig planting pits 1 ~ times the width and 1 time the depth of the root ball. Fill pits with backfill mix to the depth of the root ball and irrigate thoroughly. Be sure entire root ball area is covered when planting. 3.Contractor shall be responsible for obtaining soil tests and preparing backfill mix per soil test recommendations. Submit soil test results to City Inspector for approval prior to soi! amending and/or backfilling. 5. Pre-Planting Weed Abatement a. Upon completion of all fine grading and soil preparation, perform weed control measures as follows: 1) Irrigate all areas to be planted for a minimum of 10 minutes twice per day, for seven (7) consecutive days to sufficiently germinate all weed seed as possible. Adjust irrigation run times ta avoid run-off. 2) Apply □ contact herbicide Round-Up, Rodeo, or equal, and allow sufficient time to obtain a complete kill of germinated weeds. Approximately 7 to 10 days. 3) Repeat a second 'grow and kill' cycle repeating steps 1 and 2. Knack down and or grub-out dead noxious weed material as necessary during installation of straw netting and shrub installation. f. Prepared Soil for Drip Irrigated Planters g. Rake and clear all proposed turf planter areas clear of organic and/or construction debris. h. Rip existing soil to a minimum uniform depth of 12"inches and 3"minimum crumb size. i. Amend area per soil preparation note 0.3.above. Rototil in all amendments to a depth of 811 and a 1-1 /2" to 2" soil crumb size. E. PLANTING 1. General a. Set plant plumb and hold rigidly in position until soil has been tamped firmly around ball or roots. b. Use only specified backfill mix for bcrckfill of planter pit. c. Gro Power 7 Gram Plant tabs per the Fallowing: 1 gol shrub ... 3 tabs/plant 5 gal shrub ... B tabs/plant 15 gol tree ... 15 lobs/plant d. Tri-C Myco-Paks Endo/Ecto Mycorrhizae fn the following □mount: Tea Bag Qty Plant Size 1 1 Gal 2 5 Gal 4 15 Gal 5 24"Box e. Backfill pit with mix to half its depth and water thoroughly. Back fill remainder of pit with mix. Top down firmly to eliminate all air pockets. Do not compact. f. Construct watering basins equal to diameter of pit excavated for planting plant material. Depression of each basin shall be capable of holding a depth of 3 inches of water. g. After watering, any settlement within basins shall be refilled to required grade with prepared soil. 2. Container-Grown Plants a. Con removal: Do not injure root ball. Carefully remove plants without injury or damage to root ball. After removing plant. superficially cut edge-roots with knife on three sides. b. Box removal: Remove bottom of plant boxes before planting. Remove sides of box without damage to root boll ofter positioning plant and partially backfilling. c. Dig planting holes to accommodate root bolls as per detail on plans. d. Hand backfill and hand tamp leaving a slight depression around plants. F. STAKING OF TREES 1. Stoke designated trees as per detail, with minimum of one stake on windward side of tree. G. TREE ROOT BARRIERS 1.The Contractor shall furnish and install tree root barriers as specified. The tree root barriers shall be product /IUB36-2 (36 " depth) and /IUB24-2 (24" depth) as manufactured by DeepRoot Green Infrastructure, LLC; 530 Washington Street, San Francisco, CA 94111 info@deeproot.com Tel: 415-781-9700 Toll Free:800 458-7668, or approved equal. 2.The barriers shall be black, injection molded panels, of 0.085" wall thickness in modules 24" long by 36" deep; manufactured with a minimum 50% post-consumer recycled polypropyiene plastic with added ultraviolet inhibitors; recyclable. 3.The Contractor shall install the root barriers devices in a linear fashion adjacent to paving, sidewalk, or curb in all conditions where trees ore to be planted within 7' or closer to these improvements. Root barriers shall extend 8' on each side of tree as measured along length of improvement. 4.The vertical root deflecting ribs shall be facing inwards to the root ball and the double top edge shall be 1 /r above grade. DESIGNED BY: ~E-E __ _ DATE: 04/21/2026 DRAWN BY: ~E~E ____ SCALE: PS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 H. EROSION CONTROL 1. Erosion control straw and coir blankets or approved equal shall be installed along with plonting on all slopes in excess of 6: 1 (16% gradient). 2. Erosion control blankets shall be as manufactured by American Excelsior Company - Arlington, Texas and available through John Deere Landscapes. 3. Application of straw blanket shall conform to the following. a. Slopes 6: 1 and up to 3: 1 receiving container stock -Single Netting FibreNet b. Slopes steeper than 3:1 receiving container stock -Double Netting FibreNet. 1. Slopes 6:1 and steeper receiving hydroseed and container stack -Cair Mesh-40 weight coconut fiber net. All erosion control netting shall be natural biodegradable coir type fiber netting. Poly-fiber netting shall not be used.p 2. Best practices shall be incorporated to insure areas with straw balnkets receiving hydroseed are sufficiently prepared prior to hydroseeding. Coordinate work with hydroseed contractor prior to installing straw blankets. I. GENERAL 1. Maintenance for all palm planting areas will be for a minimum of 120 days exclusive of other maintenance requirements for the project. The Contractor shall also follow direct maintenance as specified. Refer to Specification Section J for additional information and direction. 2. Mulch Application a. All planting areas, with the exception of areas with slope gradients in excess of 33.3% (3: 1 and greater) shall receive o 3" layer of mulch. b. Mulch material shall be recycled tree trimmings containing no grass, weed seed, trash or other contaminants. Screened to 3" minus fines. conforming to 'Forest Fines' or eq. Available through Agri-Servlce 1-800-262-4167. Submit sample to Landscape Architect for approval prior to bulk delivery to job site. c. Additional mulch application may be required during maintenance/establishment to maintain 3» layer depth due to settling and compaction. J. SUBMITTALS 1. Contractor shall submit 3 copies of manufacturer cut sheets of all materials required to complete landscape planting phase. Submittal shall be reviewed by landscape architect. 2. Contractor shall review each submittal package for project application and conformance. Each submittal set shall be stamped by the contractor certifying sold review. 3. Landscape Plant Material a. Contractor shall submit color photos of all material over 15 gallon container size. b. All material less than 15 gallon size shall be listed and nursery source identified; no photos of stock ore necessary. 4. Soil Additives and Mulches a. contractor shall submit 1 quart physical samples of bulk soil additives for review. K. GUARANTEE Alt shrubs and trees shall be guaranteed by the Contractor for the following lengths of time upon completion of the specified maintenance period: 1. Al! trees and shrubs for duration of maintenance period. 2. All one gallon shrubs -120 days. 3. All five gallon trees and shrubs -120 days. 4. All 15 gallon trees and larger -1 BO days. L. MAINTENANCE 1. The entire project shall be completely and satisfactorily maintained for a period of 120 calender days. The Contractor shall call for the start of establishment/maintenace once the project is substantially complete -(100% hardscope, f!atwork and furnishings installed -95% Planting & Irrigation installed). Establishment and maintenance period shall commence upon the date of completion of the work, as authorized in a written notice from the Landscape Architect after a 'start of establishment period' inspection has been completed by the Owner's representative; and all punch list items have been corrected by the Contractor. 2. Maintenance shall consist, but not be limited to, the following: a. Care and maintenance of plant basins for container stock. Removal of known noxious weeds from project area. b. Replacement of diseased or dead container stock. c. Clearing of drainage structures of debris that might impede the flow of water through them. d. Weekly edging & mowing and/or inspection of all turf areas. e. Removal of all trash, debris and plant litter from site. f. Cleaning, brush or power washing of flatwork and furnishings at least one time, or more if directed by the Owner or Landscape Architect. g. Contractor shall be responsible for protecting the work from vandalism and accidental damage, damage by frost or torrential rains. Any damage shall be promptly repaired at no additional cost to the Owner. h. Contractor is responsible for all repairs or replacements caused by acts of vandalism, including removal of graffiti, and/or refinfshing as required. i. Contractor shall inspect the site no !ess than once per week during the maintenance period. j. Initially feed with 20 lbs. Gro-Power Plus per 1000 sq. ft on day 45 and 85. Thereafter, feed with same product at same rate every 8 to 12 weeks, depending on usage and/ or desired level of maintenance. 3. Finol Acceptance a. The Contractor shall show evidence to the Landscape Architect that the Owner has received oil required manuals, accessories, maintenance recommendations, etc. before final inspection con occur. b. Notification by the Contractor shall be made in writing to the Landscape Architect ot leost seven (7) calend-er days prior to final inspection for occeptonce. The final inspection of the work shall be made in the presence of the Owner's representative and the City Landscape Inspector at the time the work is completed. IV. HYDROSEEDING A. Hydroseed slurry composition shall be as follows: 1. Component Cel-Fiber, Central fibers 2nd Nature Gro-power Plus 5-3-1 w/M Gro-Power Controlled Release (12-8-8) Enviro-Mend M Binder I THE .. LIGHTFOOT PLANNING GROUP PLANNING QTY/ area 1500-2500 lbs/acre 1000-1300 lbs/acre 400 lbs/acre 40 to 160 lbs/acre 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE B. All seed shall be new crop seed labeled in accordance with US. Department of Agriculture rules and shall be furnished in sealed, standard containers. Seed which has become wet, moldy, or otherwise damaged, will not be acceptable. C. Seed and/or stolon types shalt be as specified and shall be applied at the rates indicated above. D. Mulch material shall be clean. natural wood cellulose fiber. Natural wood cellulose fiber shall be processed in such a manner that it will contain no growth or germination inhibiting factors and shall be dyed green to facilitate metering of materials. It shall be manufactured in such a manner that after each addition and agitation in slurry tanks with fertilizer, seed, water, and other approved additives, the fibers in the material will become uniformly suspended to form o homogeneous slurry; and that when hydraulically sprayed, will uniformly cover the ground with seed and mulch, and which after application, will allow the absorption of moisture and will allow rainfall to percolate to the underlying soil. Materials which inhibit germination or growth shall not be present in the mixture. E. Stabilization and water retaining agents shall be Ecology Controls nM" Binder, or approved equal. F. Fertilizer shall be an approved standard brand conforming with pertinent State fertilizer laws, uniform in composition, dry, and free flowing. G. Fertilizer shall be a commercial grade, uniform in composition, dry, and free flowing, of analysis as noted on drawings, and particle size of not less than 2% through a number 48 mesh. H. Fertilizer shall be delivered to the site in the original unopened container, bearing the manufacturer's guaranteed analysis. Any fertilizer that becomes caked or damaged will not be acceptable. l. Hydroseeding will follow container planting. All seed shall originate in the vicinity of coastal North San Diego County. All seed shall be delivered to the project area in sealed containers. All seed shall be labeled according to state and federal laws. Each sealed container shall bear the seed supplier's tags which shall indicate the container weight, seed type (genus and species), seed purity %, seed germination % and date seed tested. Samples of each seed mix may be drawn at the time of delivery to the area by the restoration ecologist. Samples may be tested to assure compliance with the seed specifications. The restoration ecologist shall conduct a pre-planting meeting to instruct the hydroseeding crew regarding acceptable application technique. The restoration ecologist shall then remain an-site to oversee hydroseeding. J. Per Hydroseeding weed abatement upon completion of fine grading installation of irrigation and soil preparation, The contractor shall perform weed control measures as follows: 1. Irrigation all areas to receive hydroseed to facilitate sufficient weed germination. 2. Weed and grub noxious weed growth. 3. Irrigate area thoroughly to generate any additional germination. 4. Spot spray herbicide Rodeo or Roundup 5. Wait 7 days prior to beginning hydroseed operations. _DI /\PPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PL1\NT!NC ARE.A. ' DIAL TOLL FREE 1 -800 -422 -4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA T-3 RCE ___ _ EXP. ____ _ DAT[ REVIE\./ED BY, INSPFCT □R DATE 7/08/26 6/16/26 5/05/26 1------+---+-----------+----+--+----+----t I SHE.3ET 11 CITY OF CARLS B i\D I ~==:::::_,':· :::::::::::::=::::::::::;P::;:LA~N:;N::IN::::G::::::Dl:::Vl::::S::::10:=N=====~ LANDSCAPE IMPROVEMENT PLANS FOR: POINSETTIA PROPERTIES (WATERS END) SPECIFICATIONS NOTES 1------+--+-----------+----1--+----+------1 \-AP_PR_o-----'v0'-"~=~----nh=,t=Jtfd,=V~-- . PLANNING Z, DATE INITIAL ENGINEER OF WORK Expiration Oote:10/31/26 REV!S 1ON DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL DWN BY: EE CHKD BY: JT RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-?T DI RT DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA I i "I I I ~- ~l-,c ... -t .. • ' 9 I . ... i ;· i . I I I I I I I CONTROL VALVE SYMBOL A TES VALVE NO. r-"fDICA TI:$ CONTROLLER NDICAT£S 8PM '--....,'NDICATES VALVE SIZE IRRIGATION EQUIPMENT LEGEND VALVES, CONTROLS, 4 MISC. EQUIFMENT DETAIL 5YM. MANIJFAC,TURER / MODEL # DESC.RIPTION • RAINBIRV XC.Z-150-LGS-SERIES DRIP RfMOTE WNTROL VALVE A95EMBL.Y C,/22, REMOTE WNTROL DRIP VAL VE Yl!TH C,HRISTIES I.D. TA6 FOR STATION NUMBER FILTER 4 PRE55URE REGULATOR BRAND BOX LID 'STA.#" 5U65UivACE DRIF LINE DETAIL 5YM. DE5C.RIPTION 6PM -AT 40 PSI REMARK ~ RAINBIRP XFD SERIES DRIPPER LINE 1.54 PER 100' L.F. A.-J/2! RAINBIRP XFD-o<!-12 FLOll'l, o_q 5PH ON-SURFACE EMITTER 5PAGlt.5, 'IN-LINE' EMITTER A/ 2a. AVAILABLE IN 100' OR 500' C,OIL LEN6TH5 12"0~. DRIP TUBIN6 HEADER AND EXHAUST LINES TO DRIP LINE ~IP LINE 5PAGlt.s, SHALL BE PYG C,LS. 200 SOL VENT 1/'lELD PIPIN6 0~. SURFACE DRIP LINE NOTES, INSTALL MAl'IJAL LINE FLJJ5HIN6 VALVE F!:R DETAIL 6/21!, AT LO>'l POINT AND AT END OF EACH SYSTEM INSTALL FLJJ5H VALVE PUMlED ON PVC, EXHAIJ5T HEADER I PER MAl'IJFAGTil<ERS RECOMMENDATIONS. INSTALL RAIN61RV AIR RELIEF VALVE ARVOSO AT Hl6H POINT OF EACH SYSTEM. INSTALL PER DETAIL E/2/!, AND MAl'IJFAGTil<ERS REGOMMENDATIONS. INSTALL DRIPLINE /'SOVE 6RADE IN A LINEAR PATTERN TO AVOID PLANTIN6 Dl5TIJl<6ANGI:. REFER TO LAYOl!r DETAIL ANC-HOR i'ITH 6" YllRE SOIL STAPLES AT 4' O~. C,HAN5E5 IN DIREC,TION, AND AT ALL PVC, TO POLY flTTIN65 DRIP LINES TO 6E INSTALl.fD 6" C,LEAR OF PAVIN6, HARD5GAPE, C,IJRB ED6E5 AND WVERED BY 3' OF BARK MJLC,H. DRIPLINE LATERAL SHALL NOT EXGEfD 230' LINEAR FEET BfTVEEN PVG 5IJPPL Y I EXHAUST HEADERS. INSTALL tlJNTER EW-ID DRIP OPERATION INDICATOR MIN. OF ONE FER VALVE SYSTEM. IT SHALL 6E PLACED AT THE END OF SYSTEM FER DETAIL D/22>. INDIGATOR TO 5HO>'l If DRIP 15 OPERA TIN6. PSI READIN6 SHALL 6E REWRVED AT END OF DRIP SYSTEM INSTALLMENT FOR Fl/ME MAINTENANGE MONITORIN6. IRRIGATION KEY NOTES EXISTING SPRAY I-IEADS TO BE REMOVED AND CONVERTED TO DRIP IRRIGATION SYSTEM. TYPICAL CONTRACTOR TO VERIFY PIPE LAYOUT OF PARKWAY DRIP CI-IANGES PRIOR TO MODIFICATION REFER TO TYPICAL FARKUJAY IRRIGATION DETAIL A/29. EXISTING IRRIGATION VALVE TO BE REPURPOSED AND REPLACED UJITI-I DRIP KIT <PRESSURE REGULATOR, AND FILTER TYP.J CONTRACTOR TO VERIFY VALVE OPERATION LAYOUT OF PARKWAY DRIP CI-IANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. NOTE: ALL INTERIOR PROJECT TO BE IRRIGATED USING POTABLE WATER. TYPICAL APPROVED r OR I RRi Gt\ Ti ON AND PLANTING ONLY, INCLUDING PRECIS LOCJ\TION OF PLANTING AREA. 2237 FARADAY AVENUE SUITE 120 CARLSBAD.CA 92008 {760) 692-1924 www.lightfootpg.com SITE DESIGN IANDSCAPE ARCHITECTURE Ll-1 // AS BUlL I II RC[ __ _ EXP. __ _ DATE REVIE\✓ED BY INSPECTOR DA TE 7/08/26 rl-====r====r===========================[===r===J====r===]r:::::==~::::::::=====================:::1 6/16/?6 ISH4EETII CITY OF CARLSBAD 5/05/26 l----+---+--------------l----l-----+---1----1 _ PLANNING DIVlSION r----:::;::=::;:::---,1-----_-_-i-_-_--+t_-_-_-_-_-_-_-_~---_-_-_-_-_-_-_-_-_-_-_-_--+t_-_-_-+1_-_--1t_-_-_--lt_-_---17 ;::::=='-==========:'::'::======~ I LANDSCAPE IMPROVEMENT PLANS FOR DESIGNED BY: -'E==-E __ DATE: 04/21/2026 DRAWN BY: EE SCALE: ftS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 POINSETTIA PROPERTIES (WATERS £ND) iRRIGA TION SHEET l---l---+----------------1-----1----+----I----I I APPROVED/ IJ _ _ _ 7A ~ /'~ 1/JJJ(-Zll 1-----+---+---------------+----+---+---+---I ;:::~P=LAN=N=ING========:::;-;:=:=='=====::;-;::::=D=AT=E==:I l--~--+---+--------------l-----1----1---+---I OWN BY: _.,,EE~_ l--□-AT_E......1...._INIT_IA_L +--------------+...=,DA::.::aE---1....::.IN::.clTIAL=-J__:;.OA::.::TE---1....::.'N::.clTIA::.::L-I CHKO BY: =JT __ Expiration Uote:10/31/26 ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-?T \ \ \ \ \ \ ; \ \ . \ \ I \ ' ' . \ • I I • I \ \ ' \ I RT DIAL TOLL FREE 1-800-422-4133 AT LEAST iWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA \ EXISTING MARINE IS LOCATED 8" TO 1. -0' FROIII BACK OF CUll8 !TYP.I TO REMAIN. I RED coftAL. T'T'P. el r------- DESIGNED BY: EE DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 EXISTING __ IIAIII.INE 18 LOCATED e• TO 1 '-0" FROII BACK OF CURI ITYP.I IRRIGATION EQUIPMENT LEGEND ' ' • I 7/08/26 6/16/26 5/05/26 TO REMAIN. PLANNING ' ' EXISTING VALVES, CONTROLS, 4 MISC. EGlUIFMENT DETAIL SYM. MANUFACTURER / MODEL # DESCRIPTION • RAINBIRD XC,Z-I50-LC,5-SERIES DRIP REM01l: CONTROL V ;,.J. VE A55EMBL Y (,/'le, REMOTE CONTROL DRIP V ;,.J. VE VilTH CHRISTIES 1.D. TA6 FOR STATION NUMBER FIL Tl:R 4 ~ RE6ULA TOR BRAND SOX LID ''STA. I" 5U65UFifACE DRIP LINE DETAIL 5YM. DESC,RIPTION 6PM • AT 40 PSI REMARK ~ RAINBIRD XFD SERIES DRIPPER LINE 1.54 PER 100' L.F. A·J/21 RAINBIRD XFD-0<!·I:2 FLOVi, o_q 6PH ON-SURFACE E11JTTER 5PAC.IN6, 'IN-LINE' EMITTER A/ 2<1 AVAILAELE IN 100' OR 500' COIL LEN6TH5 1:2 O.C,. DRIP 11Jll/N6 HEADER AND EXHAUST LINES TO DRIP LINE DRIP LINE 5PAC.IN6, SH1'J.L BE PVC CL5. 200 SOL VENT t'IELD PIPIN6 1211 O.C,. SIJRFACE DRIP LINE NOTES, INSTALL MANUAL LINE FLIF.lilN6 VM.VE PER DETAIL 6/2e AT LOVi POINT AND AT END OF EAC,H SYSTEM INSTM.L FLIF.li V;,.J.VE PLUMBED ON PVC. EXHAIJ5T HEADER 4 PER MANIIFAC,11JRER'5 REWMMENDATION5. INSTALL RAINBIRD AIR RELIEF VM.VE ARV050 AT Hl6H POINT OF EAC,H SYSTEM. INSTALL PER DETAIL E/2& AND MAN!JfAC,11JRER'5 REc.OMMENDATION5. INSTALL DRIPLINE AfXJVE 6RADE IN A LINEAR PATIERN TO AVOID PLANTIN6 DISllJRBANC.E. REFER TO LAYOUT DETAIL ANCHOR rlTH 6' Vi\RE SOIL STAPLES AT 4' O.C.., CHAN6E5 IN DIRECTION, AND AT ALL PVC, TO POLY FITTIN65 DRIP LINES TO BE INSTM.LED 6" C.LEAR OF PAVIN6, HARDSC,APE, GI.RB ED6ES AND W\IERED B'1' 5" OF BARK MULCH. DRIPLINE LATERAL SHALL NOT EXCEED 250' LINEAR FEET BETYffN PVC, SIJPPL Y 4 EXH/IIJST HEADERS. INSTALL HJNTER EW-ID DRIP OPERATION INDIC.ATOR MIN. OF ONE PER VM.VE 5'1'5TEM. IT SHALL BE PLAC.ED AT THE END OF SYSTEM PER DETAIL D/28. INDIC.ATOR TO SHOVi IF DRIP 15 OFERATIN6. PSI READIN6 5HALL BE REc.ORDED AT END OF DRIP SYSTEM INSTALLMENT FOR FIJT\A<E MAINTENANCE MONITORIN6. IRRIGATION KEY NOTES EXISTING SPRAY !-lEADS TO BE REMOVED AND CONVERTED TO DRIP IRRIGATION SYSTEM. TYPICAL CONTRACTOR TO VERIFY FIFE LAYOUT OF PARKWAY DRIP C!-lANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/2S. EXISTING IRRIGATION VALVE TO BE REPURF05ED AND REPLACED WIT!-l DRIP KIT (PRESSURE REGULATOR, AND FILTER TYFJ CONTRACTOR TO VERIFY VALVE OPERATION LAYOUT OF PARKWAY DRIP C!-lANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. IIAINUME 18 LOCA TEI) &" TO 1 • -0-' FROM BACK OF CURB ITVP J TO REMAIN. NOTE: ALL INTERIOR PROJECT TO BE IRRIGATED USING POTABLE WATER. TYPICAL 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 1]60) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE II HATCH INDICATES AREA SHOWN ON TIIS SIEET ICfflW' ~ Ll-2 APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDl,NG PRECISE LOCATIC)N C)F PLANTING /\REA. 11 AS BUILT 11 RCE ___ _ EXP _____ _ DATE REVIE\,JED BY, INSPECT DR DATE 0-----+--+----------------+-----+---1-----+---IISHESETII _ PLANNING DIVISION ~==--=======:::::':::::':==========::::::1 CITY OF CARLSBAD LANDSCAPE IMPROVEMENT PLANS FOR: POINSETTIA PROPERTIES {WATERS £ND) IRRIGATION SHFFT I APPROVED/'/) IL l----+---H---------------+---+---l---+-----1 ~ I"#~ 1-----;---t---------------------t----+----+---t----➔ PLANNING / J/111[21< DATE DATE INITIAL DATE INITIAL DATE INITIAL DWN BY: CHKD BY: EE JT PROJECT NO. DRAWING NO. ENGINEER OF WORK Expiration Date:10/31/26 REVISION DESCRIPTION OTHER APPROVAL Cm' APPROVAL RVWD BY: LPC2026-0014, CT000016 396-7T DI •. -· ' ' , .. RT DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU mG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA TYP. fZYJ r---...:: H Ii Ii ' •• I 11 l ' -DESIGNED BY: ~EE~--DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 I THE ,-LIGHTFOOT PIANNING GROUP PLANNING IRRIGATION EQUIPMENT LEGEND VALvES, CONTROLS, 4 MISC. EQUIFMENT DETAIL 5YM. MANUfAc.TIJRER /MODE!.# DESCRIPTION • RAINBIRD XCZ-I50-LGS-SERIES DRIP REMOTE CONTROL VALVE A55EM6LY e,/2e, REMOiE GOl-liROL DRIP VALVE YilTH CHRISTIES ID. TA6 FOR STATION NUMBER FILTER i PRE55URE RE51JLATOR 6RAND eox LID 'STA.#" SUBSURFACE DRIP LINE DETAIL 5YM. DE5C-RIPTION 6PM·AT40~ REMARK ~ RAINBIRD XFD SERIES DRIPPER LINE 1.54 PER 100' L.F. .6,-J/21 RAINBIRD XFD-O'T-I2 FLOYi, O.'I <SPH ON-SURFACE A/ 2Q. AYAILABU' IN 100' OR 500' COIL U'N6THS EMITIT:R 5PAGIN6, 'IN-LINE' El-!ITTl:R 12" 0.C,. DRIP TUBIN6 HEADER AND EXHAU5T LINES TO DRIP LINE ~I1~:N,NE 5PAGIN6, SHALL BE PVC CL5. 200 SOL VENT YiELD PIPING SURFACE DRIP LINE i'!OiES, INSTALL MANUAL LINE FLl.6HIN6 VALVE FER DETAIL r,r,e, AT LOYi POINT AND AT END OF EAGH SYSTEM INSTALL FLUSH VALVE PU,!,l8ED ON P'IC EXHAUST HEADER 4 FER MANUFAGTIJ<ER5 REGOMMENDATIONS. INSTALL RAINBIRD AIR RELIEF VALVE A~CfSO AT HIISH POINT OF EAGH SYSTEM. INSTALL PER DETAIL E/2t> AND MANUFAG'JU<ER5 REWMMENl?ATION5 . INSTALL DRIPLINE N30VE 6RADE IN A LINEAR PATIT:RN TO AVOID PLANTINS D\Si\JRBANGE. REFER TO LAYOJT DETAIL ANCHOR l'ITH 6' l'IRE SOIL STAPLES AT 4' O.C,., GHAN6ES IN DIREGTIQ!'\ AND AT ALL P'IG TO POLY FITTIN65 DRIP LINES TO 6E INSTALLED 6" CU'AR OF PAVINS, HARDSCAPE, C,l/R6 ED6ES AND WVERED BY 5" OF BARK t-lJLGH. DRIPLINE LATERAL SHALL NOT EXCEED 250' LINEAR FEET BETYiEEN P'IG 5\JPPLY 4 EXHAUST HEADERS. INSTALL HJNTER EW-ID DRIP OPERATION INDICATOR MIN. OF ONE FER VALVE SYSTEM. IT SHALL BE PLAGED AT THE END OF SYSTEM PER DETAIL D/'2t>. INDICATOR TO SHOYi IF DRIP 15 OFERATINS. PSI READIN6 SHALL 6E RfGORDED AT END OF DRIP SYSTEM IN5TALLl-!ENT FOR FI/T1JRf MAIITTENANGE MONITORIN6. IRRIGATION KEY NOTES EXISTING SPRAY I-IEADS TO BE REMOVED AND CONVERTED TO DRIP IRRIGATION SYSTEM. TYPICAL CONTRACTOR TO VERIFY PIPE LAYOUT OF PARKWAY DRIP CI-IANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/2S. EXISTING IRRIGATION VALVE TO BE REPURPOSED AND REPLACED WITl-1 DRIP KIT (PRESSURE REGULATOR, AND FILTER TYP.> CONTRACTOR TO VERIFY VALVE OPERATION LAYOUT OF PARKWAY DRIP CI-IANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/2S. ALL IRRIGATION 5Y5TEM5 5!-IALL BE EQUIPPED WIT!-! AN AUTOMATIC CONTROLLER CAPABLE OF DUAL OR MULTIPLE PROGRAMMING. CONTROLLER MU5T !-IA.VE NON-VOLATILE MEMORY, MULTIPLE CYCLE 5TART CAPACITY AND A FLEXIBLE CALENDAR PROGRAM. Tl-IE CONTROLLER 15 TO 5C!-IEDULE IRRIGATION EVENTS USING EIT!-IER ETO WEAT!-IER BASED OR MOISTURE 5EN50R DATA, AND MU5T INCLUDE A RAIN 5EN51NG 51-iUT OFF DEVICE. EXISTlNG POINT OF CONNECTION: 2237 FARADAY AVENUE SUITE 120 CARLSBAD.CA 92008 (760) 692-1924 www.lightlootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE II HATCH INDICATES AREA SHOWN ON TIIS SIEET .£!..i:j.. ---~ •,,..11 .. , ... ,~a-, D A.PPROVEO FOR IRRIGfa,TION ANO PLANTING ONLY, INCI_UOING PRECISE LOCATION U~ PLANTING AREA. 11 AS RCE __ _ EXP, ___ _ D/\TE REVIE\,/ED BY, INSPECTOR DATE 7/08/26 6/16/26 l---+--t-------------f----+--+----I----I I SHE6ET 11 CITY OF CARLSBAD 5/05/26 . PLANNING DIVISION .---~:=:=:::;::::---1,__-_-_-_ti-----_l-+---_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_J-_-_-_i+---_-J-_-_-_7+---_---l---1 ~==--'====:::::::::::===========~I I , LANDSCAPE IMPROVEMENT PLANS FOR: POINSETTIA PROPERTIES {WATERS END) IRRIGATION SHEET APPROVED , f, t.R lzlR PLANNING DATE DATE INmAL Expiration Dctc:10/31/26 ENGINEER OF WORK REVISION DESCRIPTION DWN BY: EE PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL CHKO BY: JT LPC2026-0014, OTHER APPROVAL C\1Y APPROVAL RVWD BY: CT000016 396-?T DIG RT DIAL TDLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA j EXISTING MAINLINE IS LOCATED r-12" -.___ FIIOII BACK OF CURB (T'IP.J TO REMAIN. f: ' • i / ' I ,' J f i ' . ! ' _/ I ' • i ' ; . - \ 1\ ., I \ i 112) \ ' "'i I VALVEN DESIGNED BY: _.,,,EE~--DATE: 04/21/2026 DRAWN BY: EE SCALE: PS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 ' ' \ l I i .. ' 11 .. I , .. 1 I THE I I I I I I I I ., LIGHTFOOT PIANNING GROUP PLANNING H IU IRRIGATION EQUIPMENT LEGEND VALVES, CONTROLS, 4 MISC. EQUIA"IENT DETAIL 5YM. MANUFACTURER/ MODEL# DESCRIPTION • RAINBIRD XQ-I50-1£5-SERIES DRIP REMOTE CONTROL VAL VE A55EMBLY (,/2/!J REMOTE CONTROL DRIP VAL VE l"IITH c.HRISTIES ID. TAf, FOR STATION NUM6ER FILTER t PRE9SIJRE RE6ULATOR 6RAND EIOX LID '~TA#" SU6SUFifACE DRIP LINE DETAIL 5YM. DESCRIPTION 6PM -AT 40 l'Sl REMARK ~ RAINBIRD XFD SERIES DRIPPER LINE 1.54 FER 100' L.F. A-J/2! RAINBIRD XFD-0'1-12 FLOl"I, o.q 6PH ON-SURFAa El:'IJT!ER 5PAC,IN6, 'IN-LINE' EMITTER A/ 2'1 AVAILA6LE IN 100' OR 500' WIL LEN<STHS 12 0,(,, DRIP TI!BIN6 HEADER AND EXHAUST LINES TO DRIP LINE P.!!,IP LINE 5PAC,IN6, SHALL BE PVC, C,LS. 200 SOL VENT l"IELD PIPIN6 12 0,(,_ SLRFAC,E DRIP LINE NOTES, INSTALL MANUAL LINE FLUSHIN6 VALVE PER DETAIL 6/2/!, AT LOl't POINT AND AT END OF EAC,H SYSTEM INSTALL fU!SH VALVE PJ.IJMBED ON PVC EXHAUST HEADER 4 PER MANl,fAC,ilJl<fRS RECOMMENDATIONS. INSTALL AAIN6IRD AIR RELIEF VALVE A'i'YOSO AT Hl5H POINT OF EAC,H SYSTEM. INSTALL PER DETAIL E/2/; AND MANJFAC,ilJl<fR'S RECOMMENDATIONS. INSTALL DR/PLINE "80VE 6RADE IN A LINEAR PATTERN TO AVOID l'LANTIN6 DIS1URBANCE. REFER TO LAYCI/T DETAIL• ANCHOR ~TH 6" f'!IRE SOIL STAPLES AT 4' O.C,., atAN6ES IN DIREC,TION, AND AT ALL PVC TO POL'!' FITTINGS DRIP LINES TO BE INSTALLED 6' aEAR OF PA'i'IN6, HARDSC,APE, C,IJR6 ED6ES AND COVERED BY 3' OF BARK ~H. DRIPLINE LATERAL SHALL NOT EXCEED 230' LINEAR FEET BETl"f'EN PVC SUPPL 'I' 4 EXHAIJ5T HEADE!<S. INSTALL HINTER EW-ID DRIP OPERATION INDIC,ATOR MIN. OF ONE PER VALVE SYSTEM. IT SHALL BE Pl.ACED AT THE END OF SYSTEM PER DETAIL D/2fl. INDICATOR TO SH0'1 IF DRIP IS Oi'fRATIN6. PSI Rl:ADIN6 SHALL BE RECORDED AT END OF DRP SYSTEM INSTALLMENT FOR Fl/ME MAINTENANC,E MONITORIN6. IRRIGATION KEY NOTES EXISTING SPRAY 1-lEADS TO BE REMOVED AND CONVERTED TO DRIP IRRIGATION SYSTEM. TYPICAL CONTRACTOR TO VERIFY PIPE LAYOUT OF PARKWAY DRIP Cl-lANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. EXISTING IRRIGATION VALVE TO BE REPLlRFOSED AND REPLACED WITJ-1 DRIP KIT (PRESSURE REGULATOR, AND FILTER TYP.J CONTRACTOR TO VERIFY VALVE OPERATION LAYOUT OF PARKWAY DRIP Cl-lANGE5 PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. NOTE: ALL INTERIOR PROJECT TO BE IRRIGATED USING POTABLE WATER. TYPICAL EXISTING • MAIN I.VE IS LOCATED r.12• FftOII BACK OF ¢UIII ITlP,I TO REMAIN. 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE L!-4 HATCH INDICATES AIIEA 9IIOWN ON THIS SIIEET .~PPROVED FOR IRRIGATIO,I\J AND PLAI\JTING ONLY, INCLUDI.I\JG PRECISE LOC;\ TION 01 PLANTl;I\JG AREA. RCE __ _ EXP. ___ _ DATE RE\/IEwED BY, INSPECTOR DATE 7 /0R/26 5/16/26 f------f-------+-------------l---l-----l----+--------1 I SH E7l TI CIT'{ 0 F CARLSBAD 5/05/26 PLANNING DIVISION r----==~==:::;:::::----7t=====t====j==================================±====jt====t=====t====j ~L=A=ND=s=c=A~P=E=JM=P=R=o=v=E=M=E:::::N::::1:::' ::::P::::L::::AN:=S==:F::::O::R:=:=::=====~I POINSETTIA PROPERTIES {WATERS END) IRRIGATION SHEET f---+--+--------------+--+--+--+-----11 APPROVED ~ ~ _ PLANNING / ~1/!CR(Zu DATE DATE INITIAL ENGINEER OF WORK txpirotion Do:.e:10/31/26 REVISION DESCRIPTION DATE INfTIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL OWN BY: CHKD BY: RVWD BY: EE JT PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-?T ... -EXISTING MAIM LINE IS LOCATED e•.12" FROM BACK Of CURii trYP.I TO REMAIN. DI RT DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA \ ' \ ' ' ' ' \ ' \ ' \ MAIK LINE IS LOCATED e• -12" FROM BACK OF CURB lT'IP.l TO REMAIN. DESIGNED BY: ~E~E __ _ DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 EXISTING NAIii t.lNE 1$ LOCAtm 1"-12" FROM BACK OF CURB tTYP.I TO REMAIN. I THE ., LIGHTFOOT PIANNING GROUP PLANNING IRRIGATION EQUIPMENT LEGEND VALVES, CONTROLS,, MISC. EQUIFMENT DETAIL 5YM. MANUFAC-TIJRER /MODEL# DE5C-RIPTION • RAINBIRD Xc,Z-I50-LCS-5ERIE5 DRIP REMOTI: CONTROL VAL VE A55EMBL 'I' C,/'2£:, REMOTI: GONTROL DRIP VAL VE i"llTH GHRISTIES I.D. TA6 FOR STATION NUMBER FIL Tl:R t PR!:55\JRE RE5\JLATOR SRAND BOX LID "STA.#" 5U65URFACE DRIP LINE DETAIL 5YM. DE5C-RIPTION 6PM -AT 40 PSI REMARK ~ RAINBIRD XFD SERIES DRIPPER LINE 1.54 PER 100' L.F. l>,-j/2f RAINBIRD XFD-D'l-I2 FLOl"l, o_q 5PH ON-5\JRFAGE AVAILABLE IN 100' OR 500' GOIL LENLSTHS Et1JTTl:R 5PAGIN6, 'IN-LINE' EMITTl:R A I 2«. 12 O.C,. DRIP7V6IN6 HEADER AND EXHAUST LINES TO DRIP LINE ~p LINE 5PAGIN6, SHALL BE PVG GLS. 200 50L VENT i"lELD PIPINLS O.C,. 51A<FAGE DRIP LINE NOTES, INSTALL MAHJAL LINE FUJ5HIN6 VALVE PER DETAIL r;,m AT LOl1 POINT AND AT END Of EAGH SYSTEM INSTALL FUJSH VALVE PLUlftD ON PVC, EXHAUST HEADER 4 PER MAttfAGil.RERS REGOMMENDATIONS. INSTALL RAINBIRD AIR RELIEF VALVE ARVO'SO AT Hl5H POINT Of EAGH SYSTEM. INSTALL PER DETAIL Em AND MAN!JFAGii.RERS REGO!-IMENDATIONS. INSTALL DRIPLINE Af:bvE 5RADE IN A LINEAR PATTERII TO AVOID PLANTIN6 D\51UR!lAIIC,E. REFER TO LA'l'Ol/1" DETAIL ANGHOR 111TH 6' VilRE SOIL STAPLES AT 4' OL., GHAH5ES IN DIREGTION, AND AT ALL PVC, TO POLY FITTIN55 DRIP LINES TO BE INSTALLED 6" GLEAR Of PAVIN6, HARD5GAPE, ClA<6 ED5E5 AND COVERED B'I' S' Of BARK MULGH. DRIPLINE LATl:RAL SHALL NOT EXCEED 250' LINEAR FEET BEn1EEN PVC, SUPPLY 4 EXH,',J,l5T HEADERS. INSTALL HUHTl:R EW-ID DRIP OPERATION INDIGATOR MIN. Of ONE PER VALVE 5Y5Tl:M. IT SHALL BE Pl.AGED AT THE END OF SYSTEM PER DETAIL D/28. INDIGATOR TO SHO~ IF DRIP 15 OPERATIN6. PSI READIN6 SHALL 6E RECORDED AT END Of DRIP SYSTEM INSTALLMENT FOR Mi,RE MAIN11:NA)tf MONITORN6 . IRRIGATION KEY NOTES @TI EXISTING SPRAY HEADS TO BE REMOvED AND CONvERTED TO DRIP IRRIGATION SYSTEM. TYPICAL CONTRACTOR TO VERIFY PIPE LAYOUT oF PARKWAY DRIP CHANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. EXISTING IRRIGATION VALvE TO BE REPURPOSED AND REPLACED WITH DRIP KIT (PRESSURE REGULATOR, AND FILTER TYP) CONTRACTOR TO vERIFY VALvE OPERATION LAYOUT oF PARKWAY DRIP CHANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. NOTE: ALL INTERIOR PROJECT TO BE IRRIGATED USING POTABLE WATER. TYPICAL • HATCH INDICATES AREA SH0\1,11 ON THIS SHEET ;\PPRC)VFD FOR IRRIGATION AND PLl11NTING ONLY, INCLUDING PR[CISE LOCATION OF PLANTING ARc_A. 2237 FARADAY AVENUE SUITE 120 CARLSBAO,CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE RCE __ _ REV !EwC:D BY, lNSPECT □ R I3UIL \-!I E'XP. ___ _ DATE DATl 7 /08/26 6/16/26 5/05/26 CJTY OF CARLSBAD PLANNING DIVISION l-----t---1----------------+---+--+-------+---I I SH8EETI ,---::::;::==::::::;::::----r-=--=--=--=--=-t-=--=--=--=-:t-=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=-:t-:=.:::t::::jt:-:=.:-:=.j::::j ;:L=A=:N::::n=s=c:'...AP'.:::r:=•=1=M::::P::::R:::O=:V::::E==M::::EN:=::::T=P=L=A=N:::S:::::::F::::O::::R=: =======:I POINSETTIA PROPERTIES {WATERS END) IRRIGATION SHl:.ET I A .. PPROVED / • /J ll. I r--+---+------------+--+---+---+---1 _ {./{)(d,A.1, ~UU4,/ 1/11112(.t__ t----+---+-------------------+---+---+----+---1 ~P:::LA::N:=N::IN::G=::::::;;::::=::::;-;==::::/::::========;;===D=AT=E=:::::;· DATE INITIAL ENGINEER OF WORK lxpiration Date:10/31/26 REVISION DESCRIPT,ON DATE INITIAL OTHER APPROVAL DWN BY: EE DATE INITIAL CHKD BY: JT CITY APPROVAL RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T ALL IRRIGATION SYSTEMS SI-IALL BE EQUIPPED UJITI-I AN AUTOMATIC CONTROLLER CAPABLE OF DUAL OR MULTIPLE PROGRAMMING. CONTROLLER MUST 1-!AVE NON-VOLATILE MEMORY, MULTIPLE CYCLE ST ART CAPACITY AND A FLEXIBLE CALENDAR PROGRAM. Tl-IE CONTROLLER 15 TO 5CI-IEDULE IRRIGATION EVENTS USING EITI-IER ETO UJEATI-IER BASED OR MOISTURE SENSOR DAT A, AND MUST INCLUDE A RAIN SENSING SI-IUT OFF DEVICE. ' I ' . \ \ \ \ •. \ \ • \ DI ' \ \ . ' \ I \ .. I ' \ ' ' RT DIAL TOLL FREE 1-800-422-4133 AT LEAST 1WO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUIBERN CALIFORNIA <18..1 EXISTINa POINT OF CONNEC110N: 1-V2" WATER MET'ER Willi 1-Vl!" REDUCED PRESSURE BACKfLOW PREVENTION DEVICE (POTABLE WATER) EXISTINa 24 &rA110N AUTOMATIC CONTROLLER T WITH RAIN SEtlSOR ATTACHED TI) CONTROLLER CONTROLLER GREEN 1ECH CA1-RBl-82/RSE - EXISTING -- \ '. \ \ -·- \ \ . \ . ' ; I \ \ \_ \ NOTE: ALL INTERIOR PROJECT TO BE IRRIGATED USING POTABLE WATER. TYPICAL MAIN LINE IS LOCA TEO &" • 12" FRON BACK OF CURB !TYP.I - \ .\. ' ' \ .. . \ \ "' \ ' - DESIGNED BY: EE DATE: 04/21/2026 DRAWN BY: EE SCALE: IS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 ---- 7 /08/26 THE ,. LIGHTFOOT PIANNING GROUP PLANNING IRRIGATION KEY NOTES \ \ EXISTING sPRAY l-lEADS TO BE REMOVED AND CONVERTED TO DRIP IRRIGATION SYSTEM. TYPICAL CONTRACTOR TO VERIFY PIPE LAYOUT OF PARKWAY DRIP Cl-lANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. EXISTING IRRIGATION VALVE TO BE REFURFO5ED AND REPLACED WITf-1 DRIP KIT (PRE55URE REGULATOR, AND FILTER TYPJ CONTRACTOR TO VERIFY VALVE OPERATION LAYOUT OF PARKWAY DRIP Cl-lANGE5 PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. ' \ • \ \ 1\ ... \ ' ' -- REFER TO IRRIGATION SHEET 4 FOR LEGEND. EXISTING II HATCH INDICATE$ AREA SHOWN ON THIS SHEET MAIN LICE IS LOCATED &' -12" FllON BACK OF CUll8 ITYP .I TO REMAIN. .. Kl!YMN' APPROVED FOR I RRI GA Tl ON AND PLANTING C)Nl_ Y, INCLUDING PRECISE LOCATION OF PLANTING AREA. RCE __ _ EXP ____ _ DATE 2237 FARADAY A VENUE SUITE 120 CARLSBAD,CA 92008 REV!EwED BY, (760) 692-1924 www.lightlootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE Ll-6 JNSPEC HJR CITY OF DATE CARLS BAI) 6/16/26 f----+----+-----------------1----1----l---_J_ _ __J I SHgEET 11 5/05/26 ,---::::;~==:::;::::-----i--t-_ -_ -_-_-_ft--_-_-_-_ t+--_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ l--l -_ -_ -_ -_ lj-e--_ -_ -_ -_t-1--_ -_ -_ -_ l--l -_ -_ -_ -_ -1_. :=L=A::N::::DS=C::::A~P::E==IM=P::R=o=VE:::=M::=E::::::LA:::T:::::::::::l::::::::S:=D F':=IVO:::l:=IO::::N:::======='.I POINSETTIA PROPERTIES {WATERS £ND) IRRIGATION SHl:.1:. I l---+---+---------------+--+---l-----1----11 A_P_P_R_o_v_E_D---"'---''/:' = I)'-"-"'---'~ /4-=""----~ (/j/'UUt,t/ 1{1ll(Z(R PLANNING / DATE DATE INITIAL DATE INITIAL DATE INITIAL / ENGINEER OF WORK Expiration Oate:10 31/26 REVISION DESCRIPTION OTHER AFPROVAL CITY AFPROVAL OWN BY: EE CHKD BY: JT RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T ' ' .. \ ' DI EXISTING ' ' MAIN LINE IS LOCATED $" FROM IIACK OF CURB (TYP.l TO REMAIN. RT DIAL TOLL FREE 1-800-422 -4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA DESIGNED BY: ~EE~--DATE: 04/21/2026 DRAWN BY: ~E~E ____ SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 \ ' ' I \ \ ' ' \ \ . \ \ ' . ' \\ \ ' \ . IRRIGATION EQUIFMENT LEGEND VALvE5, CONTROLS, 4 MISC. EQUIPMENT DETAIL SYM. MANIJFACTIJRER /MODEL# DESCRIPTION • RAINBIRD XCZ-I50-LC6-5ERIE5 DRIP REMOT!: GONTROL V 1'L VE A55EMBL Y C,/21!, REMOTE C,ONTROL DRIP VAL VE l'IITH C,HRl5TIE5 ID. TAf, FOR STATION NUMBER FILTER 4 PRESSURE RE<WLATOR BRAND BOX LID ''STA.#" 5U65URFACE DRIP LINE \ DETAIL SYM. DESCRIPTION 6PM -AT 40 PSI REMARK \ I ~ AAINBIRD XfD SERIES DRIPPER LINE 1.54 PER 100' L.F. A-J/21 RAINBIRD XFD·0'!-I2 FLOl'I, o_q 5PH ON-SURF AGE FJ:11TTER 5PA(;IN6, 'IN-LINE' EMTTER A/ 2'1 AVAILA6LE IN 100' OR 500' WIL LENl:>THS 12' O.C,. DRIP 11A3IN6 HEADER AND EXHAUST LINES TO DRIP LINE ~IP LINE 5P/\C,IN6, SHALL BE PVC, C,LS. 200 SOLVENT l'IELD PIPIN5 12' O.C,. EXISTING POINT OF CONNECTION: SURFAC,E DRIP LINE NOTES, INSTALL MANIJAL LINE FLLI5HIN6 VALVE PER DETAIL 5/U, AT LOYi POINT AND AT END OF E/\C,H SYST!:M 'f' WATER METER wrTH .,,--..,....a"':._-.. -11-1/4" REDUCED PRESSURE INSTALL FLLISH VALVE FLUM6fD ON PVG EXHAUST HEADER I PER MANIJFA(;i\JRERS REWMMENDATIONS. INSTALL AAINBIRD AIR RELIEF VALVE ARV050 AT Hl5H POINT OF EAGH SYSTEM. INSTALL PER DETAIL E/2!, AND MANLfAGTLIRER'S REWMMENDATIONS. I \ \ \ I \ i,. + BACKFLOW PREVENTION DEVICE INSTALL DRIPLINE ABOVE 5AADE IN A LINEAR PATTERN TO AVOID PLANTIN6 Dl511JR!l/\NC,E. REFER TO LAYOl/r DETAIL . \ \ \ ·. C. (POTABLE WATER) ANGHOR YilTH 6" YilRE SOIL STAPLES AT 4' Ot:, GHAN6E5 IN DIREGTIQI'\ AND AT ALL PVG TO POLY FITTIN65 DRIP LINES TO BE INSTALLED 6" CLEAR OF PAVIN5, HARD5GAPE, CURil ED5E5 AND GOVERED BY 9" OF BARK MIJLGH. \ ·:: . ._ ________________ _, \ DRIPLINE LAT!:RAL SHALL NOT EXCEED 2:30' LINEAR FEET BETl1:EN PVG 5IJPPL Y I EXHPIJ5T HEADERS. INSTALL HJNTER EW-ID DRIP OPERATION INDICATOR MIN. OF ONE PER VALVE SYST!:M. IT SHALL BE PLACED AT THE EXISTING 32 STATION AUTOMATIC END OF SYSTEM PER DETAIL D/2!l. INDlc:ATOR TO 5HOYi IF DRIP 15 OPEAATIN6. PSI READIN6 SHALL EE REWRDED 'D' WITH RAIN SENSOR A--fAl'TACHED TO CONTROLLER AT END OF DRIP SY&rfM INSTALLMENT FOR Fl/TURE MAINTENAHc:E MOHITORIN5. NTROLLER: GREEN TECH \ CA1-RBl-32/RSE \ ' \ I \ \_. ).-, \ ' \ \ \ \ \ \ I \ THE ' ' \,_ ., LIGHTFOOT PIANNING GROUP PLANNING IRRIGATION KEY NOTES [Q] EXISTING SPRAY 1-lEADS TO BE REMOVED AND CONVERTED TO DRIP IRRIGATION 5Y5TEM. TYPICAL CONTRACTOR TO VERIFY PIPE LAYOUT OF PARKWAY DRIP Cl-lANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. EXISTING IRRIGATION VALVE TO BE REPURP05ED AND REPLACED WIT!-l DRIP KIT (PRESSURE REGULATOR, AND FILTER TYF.J CONTRACTOR TO VERIFY VALVE OPERATION LAYOUT OF PARKWAY DRIP Cl-lANGE5 PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. ALL IRRIGATION 5Y5TEM5 SHALL BE EQUIPPED WITH AN AUTOMATIC CONTROLLER CAPABLE Of DUAL OR MULTIPLE PROGRAMMING. CONTROLLER MUST HAVE NON-VOLATILE MEMORY, MULTIPLE CYCLE START CAPACITY AND A FLEXIBLE CALENDAR PROGRAM. T+-IE CONTROLLER 15 TO SCHEDULE IRRIGATION EVENTS USING EITHER ETO WEATHER BASED OR MOISTURE 5EN50R DATA, AND MUST INCLUDE A RAIN 5EN5ING SHUT OFF DEVICE. NOTE: ALL INTERIOR PROJECT TO BE IRRIGATED USING POTABLE WATER TYPICAL 2237 FARADAY AVENUE SUITE 120 CARLSBAD,CA 92008 1760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE Ll-7 • HATCK INDICATES AREA SHOWN ON THIS SHEET IC!VIW' APPRC)V~IJ FOR IRRIC.ATION AND PLAN Tl NC ONLY, INCLUDINC.; PRFCISE LOC/\TION OF PLANTINC; ARE.A. BUILT II !<Cl __ _ EXP. ____ _ DATE REVEWED DY INSPC:CT □R DATE 7 /08/26 6/16/26 5/05/26 t---t--+----------------+---+--+----1--~ls~~ETI\ ,---::~~::::;:::------t-=--=--=--=--=-t-=--=--=--=-:t-=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=-t-::.-::.-::.-::.1-::.-::.-::.-::.-::.t-::.-::.-::.-::.-::.t-::.-::.-::.-=--.1 ~L=A=N==D=s=c A:'.,P'.::E:::::=l=M:::P::::R=o==v==E==M:::E:::N:::T =P::=L=A=N==s===F:::O:::R=: =======: CITY OF PLANNING DIVISION POINSETTIA PROPERTIES {WATERS £ND) IRRIGATION SHEET \ APPROVED!'·/} ✓A t-----1---+-----------------+---+---+----tr---1 ~ f/A.t«,t.«_L l----+---1---------------------f---+----+----f----l PLANNING / 1 /tll (Z(! DATE DATE INITIAL ENGINEER OF WORK Expiration Date:!9L~J/2~ REViSION DESCRIPTION DATE INITIAL OTHER APPROVAL DATE INITIAL CITY APPROVAL OWN BY: ~E~E~-- CHKD BY: ~JT~- RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T DI IRRIGATION KEY NOTES EXISTING 5PRA'r I-IEAD5 TO BE REMOVED AND CONVERTED TO DRIP IRRIGATION 5'r5TEM. T'T'PICAL CONTRACTOR TO VERIF'r FIFE LA'T'OUT OF PARK.WA'r DRIP Cl-lANGE5 PRIOR TO MODIFICATION REFER TO T'T'PICAL PARKWA'r IRRIGATION DETAIL A/29. RT DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA DESIGNED BY: ~EE~_ DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 THE I . _,. LIGHTFOOT _. _ PIANNING GROUP PLANNING 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (760) 692-1924 www.lightlootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE IRRIGATION EQUIA1ENT LEGEND VAL YES, CONTROLS, 4 MISC. EQUIFMENT DETAIL 5YM. MANUFACTURER/ MODEL# DESCRIPTION • RAINBIRD Xc;l-I50-l.CS-SERIES DRIP RE),IOTE CONTROL VALVE A55EMBLY C,/2/?, REMOTE WNTROL DRIP VAL YE l'IITH c-HRl5TIE5 ID. TM FOR STATION NUMeER FILTER< PRE55URE RE6U..ATOR BRAND eox LID ''STA I" SU65Ur-:FACE DRIP LINE DETAIL 5YM. DE5C.RIPTION 6PM -AT <40 PSI REMARK 1.54 PER 100' L.F. ~ RAIN6IRO XFO SERIES DRIPPER LINE ~-J/21 RAIN6IRO XFO-O'l-I2 FLOl'I, O.'f 6PH ON-5\JRFAc.E AVAILABLE IN 100' OR 500' COIL LEN6TH5 r:!:!JTTER SPACIN6, 'It-I-LINE' EMITTER A / 2"i 2 O.C,. DRIPTUBIN6 HEADER AND EXHAUST LINE5 TO DRIP LINE ~l~i;!NE 5PACIN6, 5HALI. BE PVC C.L5. 200 SOL VENT l't:LO PIPI"'7 SURFACE DRIP LINE N01E5, INSTALL MANJAL LINE FLU5HIN5 VALVE PER DETAIL 5/21?, AT I.OYt POll'IT AND AT END OF EACH SYSTEM INSTALL FLU5H VALVE Pw-el:D ON PVC EXHIIIJST HEADER I PER MANJFAC11.M:R5 RECOMMENDATIONS. INSTALL RAIN6IRD AIR RELIEF VALVE ARV050 AT HIISH POll'IT OF EACH SYSTEM. INSTALL PER DETAIL E/2& AND MAltJFAC~5 RECOMMENDATIONS. INSTALL DRIPLINE /lOO'vE 5RADE IN A LINEAR PATTERN TO AVOID PLAIITIN5 DISlURBAIICE. REFER TO LAYCUT DETAIL ANCHOR mH 6" l'IRE SOIL STAPLES AT 4' Ot,, CHAN5ES IN DIRECTIQtl. AND AT ALL PVC, TO POLY FITTIN5S DRIP LINES TO llE INSTALLED 6' CLEAR OF PA'IIN5, I-IARDSC,Al'f, GUR6 ED5E5 AND COVERED BY 9' OF BARK MUI.C,H. DRIPLINE LATERAL SHALL NOT EXCEED 290' LINEAR FEET EIE1Y£EN PVC 5Ll'FI. Y I EXH,!,IJST HEADERS. INSTALL HJHTER EGO-ID DRIP OPERATION INDICATOR MIN. OF ONE PER VALVE SYSTEM. IT SHALL llE PLACED AT 11IE END OF SYSTEM PER DETAIL D/2&. INDICATOR TO SHOYI IF DRIP IS Of'ERATIN5. PSI READIN5 SHALL llE RECORDED AT END OF DRIP SYSTEM INSTALLMEl'IT FOR F1mRE MAll'ITENANCE MONITORIN6 . • HATCH INOICATIS AREA SHOWN ON THIS SHEET RCE __ _ EXP __ _ REVIE\-/ED BY: DATE LI • 8 INSPECTOR DA lE 7/08/26 rl-::::r:::J::::::::::::::::::::::::::::J::::r:::J::::J::::..r:::====~=======================::I 6/16/26 ISH1E1ETII CITY OF CARLSBAD 5/05/26 l----+-----1----------------1----l-----l---+---I _ PLANNING DIVISION ,----:::::;::==:::;:.:-___;, __ ~====t===j============================jt===t===j====j===j ~L=AN=n=s=cA~P=E=r=M=P=Ro=VE=M=EN=T=Pl=,A=N=s=F=o=R:=====~1 POINSETTIA PROPERTIES (WATERS END} IRRIGATION SHEET !APPROVED~ ,1,,, /J. l----+-----1----------------1----l-----1---+---I ___ __,td&:1....,__..,===---H~'+-,f,,'4U14<1£.r,,4;(,L.:c:::'. __ "t / 1Lt[Z& 1----f-----f----------------1----J-----l---+---I PLANNING ,' DATE l--;:-;-;;:-f--::-:=;,,..--1---------------+---+----l---+---I OWN BY: ~EE~_ I--D_A_TE......1..._IN_ITIAL---l------------------1--..'.D::::.AT~E __L.'.'..:IN::._:mA::::L--1--::::.DA.::_:TE:........1_.::IN.::_:ITl:_::AL:._J CHKD BY: J~T __ Expiration Dote:10/31/26 ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T DI DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA ' ' \ \ \ ' DESIGNED BY: _,E=-E __ DATE: 04/21/2026 DRAWN BY: EE SCALE: PS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 • l~IGATION EQUIFMENT LEGEND VALVES, CONTROLS,• MISC. EQUIA'1ENT DETAIL SYM. MANUFACTURER / MODEL # DESCRIPTION • AAlll6IFID XCZ-150-I..CS-SERIES DRIP REMOiE CONTROL V/'d.VE ASSEMBLY C,/2b REMOTE CONTROL DRIP V I'd. YE VilTH alRl5TIE5 ID. TA6 FOR STATION NUMBER FILTI:R t PRESSURE RE6ULATOR 6RAND ElOX LID ''STA.#" SUBSURFACE DRIP LINE DETAIL SYM. DESCRIPTION iSfM -AT 40 PSI REMARK ~ RAIN6IRD XFD 9ERIE5 DRIFFfR LINE 1.54 PER 100' L.F. A-J/21 RAIN6IRD XFD·O'l-I2 FLOVi, O.'I 6PH ON-a!Rf At:,E ~TIER SPAC,IN6, 'IN-LINE' EMITTER A/2d, AVAILABLE IN 100' OR 500' WIL LENGTHS 2 Ot:,. DRIP1\.l;IN6 HEADER AND EXHAUST LINES TO DRJP LINE ~P LINE SPAC,IN6, 5HALL BE P-/C, GL5. 200 SOL VENT ViELD PIPIN6 O.C. SURFACE DRIP LINE NQT!:5, IN5TALL MANJAL LINE FLU5HIN6 VALVE PER DETAIL 6/28 AT LOl'l POINT AND AT 00 OF EACH SYSTEM IN5TALL FU/5H VALVE PUJM!3ED ON PYG EXHAUST HEADER$ PER MANLfAC,11-'<ER'S REWMMENDATIOt,15. IN5TALL AAlll6IRD AIR RELIEF VALVE Af/NO'SO AT Hl6H POINT OF EAC,H SYSTEM. INSTALL PER DETAIL E/28 AND MAftfAC,11-'<ER'S REWMM:HDATIOt,15. INSTALL DR/PLINE /'BOVE 6RADE IN A LI/IEAR PATTERN TO AVOID PLAIITIN6 DISTIA<BANGE. l<EFER TO LAYOIIT DETAIL ANGHOR l"i/lli 6' NIRE SOIL STAPLES AT 4' O.C.., c,HANi,E5 IN DtREGTI~ AND AT ALL PYG TO POLY FITTIN65 DRIP LINES TO BE INST/'d.LED 6' CLEAR OF PAVIN6, HAADSC,APE, CURB ED6E5 AND COVERED B'I' 9' OF BARK HJLC,H. DRIPLINE LATERAL SHALL NOT EXCEED 290' LINEAR ffET BETl1EEN PVC, :U'PLY t EXHAUST HEADERS. IN5TALL tU<TER Ero-ID DRIP OPERATION INDIGATOR MIN. OF ONE PER VALVE SYSTEM. IT SHALL BE PlAC,ED AT 11iE 00 OF SYSTEM l'l:R DETAIL D/28. INDIGATOR TO SHON IF DRIP 15 Ol'l:RATIN6. PSI READIN6 SHALL BE REGORDED AT END OF DRIP SYSTEM INSTALLMENT FOR Fll1U<f MAINTI:NANGE MONITORIN6. IRRIGATION KEY NOTES @TI EXISTING SPRAY I-IEADS TO BE REMOVED AND CONVERTED TO DRIF IRRIGATION SYSTEM. TYFICAL CONTRACTOR TO VERIFY FIFE LAYOUT OF FARKWAY DRIF CI-IANGES FRIOR TO MODIFICATION REFER TO T'r'FICAL FARKWAY IRRIGATION DETAIL A/2'3. EXISTING IRRIGATION VALVE TO BE REFURFOSED AND REFLACED WITI-I DRIF KIT (PRESSURE REGULATOR, AND FILTER TYF) CONTRACTOR TO VERIFY VALVE OFERATION LA'r'OUT OF FARKWAY DRIF CI-IANGE5 FRIOR TO MODIFICATION REFER TO TYFICAL FARKWAY IRRIGATION DETAIL A/2'3. NOTE: ALL INTERIOR PROJECT TO BE IRRIGATED USING POTABLE WATER TYPICAL 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN IANDSCAPE ARCHITECTURE Ll-9 • HA TCII lllllCATl'M,::;;; AREA 8ltOWII OM TIIS SIEET APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCAT!ON OF PLANTING AREA. RC[ __ _ EXP, __ _ DATE REVIEIJED BY, INSPECTOR DATE 7/os/26 r1--====r====:r:===========================:r:===1===J====1===Jr:=:::::::::~;:==::::::::====::::=====::::::::===::::::::::::::===::;i 6/16/26 ISH1E2ETII CITY OF CARLSBAD 5/05/26 1-----+----+----------------+------l-----l--_j__----l _ PLANNING DIVISION ,-----=~===::;::::----11---_ -_-_-_ti--_-_-_ t+ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ t+--_ -_ -_ i..j. -_ -_ -_ -_t-1--_ -_ -_ i..j. -_ -_ -_ i_. :=LAN====D==sc==AP~E=l==MP:;:R::O::;::VE:::M:::E:::::NT====P=LAN===s=F==o==R:=====~ POINSETTIA PROPERTIES {WATERS £ND) IRRIGATION SHEET l---t-----f------------+--+--e------l----11 A_P_P_Ro_v_ED_.,,,&1'-"it"'""""Aa_4 -U~'-L,MJ.u,,tttr,./=""----1, (111/7,c, 1-----+----+-----------------1------1-----l'----_j___....l ~~-P:::LAN::N:::ING:::::=::;;;:==::;:-;::::='=======;;==D=Aft=~ l--,--c---+---+----------------l-----1-----<1----1--------1 OWN BY: _.,,EE~_ PROJECT NO. DRAWING NO. 1-0A_TE_L._INIT_IAL-+----------------l--=-DA::.:TE----1-..::.'N::::ITl:.:::AL-1-.::DA:::JE----1-..::.'N::::ITl:.:::AL--1 CHKO BY: =Jr__ LPC2026-0014, 396 7T Exp;rnUon D□te,10/31/26 ENGlNEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL ~RWl~D_':'.BY"--: ~==l '--...:C=-.:T-.ec..OO=Qc.-=O..c..16=-------' - DI IRRIGATION KEY NOTES @TI I \ EXISTING SPRAY 1-lEADS TO BE REMOVED AND CONVERTED TO DRIF IRRIGATION SYSTEM. TYPICAL CONTRACTOR TO VERIFY FIFE LAYOUT OF PARKWAY DRIF Cl-lANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. EXISTING IRRIGATION VAL VE TO BE REFURFOSED AND REPLACED WITl-l DRIF KIT (PRESSURE REGULATOR, AND FILTER TYF.) CONTRACTOR TO VERIFY VALVE OPERATION LAYOUT OF PARK.WAY DRIF Cl-lANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL A/29. \ \ \ \ RT \ \ \ I ' \ DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG \ \ \ \ \ \ \ -, •1 UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA DESIGNED BY: ~E=.E __ DATE: 04/21/2026 DRAWN BY: EE SCALE: PS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 THE ==t=lbill! -~ .. LIGHTFOOT -_. _ PIANNING GROUP PLANNII\IG ' 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (760) 692-1924 www.lightlootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE EXISTING __..-IIAIIILIIE LOCA1ED ... t· FROM 8ACIC OF CUIB IT'IP,I TO REMAIN. RCE __ _ REVIE\JED BY, Ll-10 EXP. __ _ DATE DATE INSPECTOR 7/08/26 rf-====c===r===========================c===r===J====r===]r;:::::::::;::;:;;::-;::::::::::::::::::::;:::::;:::::::::::::::;:::::;::=::::::::::;::::;::::::::;::::::::=::=:;t 6/16/26 ISH1[3ETII CITY OF CARLSBAD 5/05/26 t----+---+--------------+----+---t--+---1 . PLANNING DIVISION ,--::;:::§::::;:::----r-,__ -_-_ -_r ..... -_ -_-_t_,__-_-_ -_ -_ -_ -_ -_ -_ -_-_ -_ -_ -_ -_ -_-_ -_ -_ -_ -_ -_-_-_ -_ -_ -_-_t+---_ -_-_ t-+--_ -_ -_ ,_, -_ -_-_ -_ t-+----_ -_ i_, :=L==AN==D==sc:;:A~P==E=I::::MP==R::::O==VE===M==E~NT~P~LA:::N:::S=;F::::O~R:=====~1 POINSETTIA PROPERTIES (WATERS £ND) IRRIGATION SHEET 1----+---+-------------t----+----+----+---flAPPROVED :' A ,,, /J,!//~J-\ UM= ~,,, 1 ( :!r1f-i1t 1-----+-----+----------------+----+---+---+-----1 ~P=LAN::N::ING:::::::::::;;::=::::;-;:=='======;-;====r=~- 1-----+----+----------------+----+---+---+-----1 OWN BY: EE PROJECT NO. DRAWING NO. 1--D_AT_E__L__1Nm_A_L +--------------+--DA_JE__,__1N_1TJA_L-+-_DA_JE__,__1N_mAL--f CHKD BY: _JT__ LPC2026-0014, RVWD BY: CTOOOO 16 ENGINEER OF WORK Ex iration Date:10/31/26 REVISION DESCRIPTION 01HER APPROVAL CITY APPROVAL 396-7T DI RT DIAL TOLL FREE 1-800-422-4133 AT LEAST lWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA EXISTING MAIIIUIIE 18 LOCATED O" • 12" FIIOM BACK OF CURB tTVP.l TO REMAIN. EXIS11NG POINT OF CONNECnON: 1-112' WAlER MEIER wmt 1-112' QEDUCEI) PRESSURE BACKFLOW PREVENTION DEVICE (POTABLE WATER) IRRIGATION EQUIPMENT LEGEND VALVE&, CONTROL&, 4 Ml5C. EQUIPMENT DETAIL 5YM. MANUFAGTIJRER /MODEL# DESCRIPTION • RAINBll<D XGZ-150-LG5-9ERIES DRIP REMOTE WN"TROL VALVE A55EMElL Y (,/21!; REMOTE (,ONTROl. DRIP VAL VE Vi!TH l:,HRISTIE5 1.D. TM FOR STATION NUMBER FILTER 4 ~ RE61A..ATOR BRAND BOX LID "STA.#" SU65UF:FACE DRIP LINE DETAIL 5YM. DESCRIPTION 6PM -AT -40 PSI REMARK ~ RAINl:IIRD XFD SERIES DRIFl'ER LINE 1.54 Pl:R 100' L.F. 6,-J/2f RAINl:IIRD XFD-o<l-12 FLOl"I, o_q 6PH ON-SURF AGE AVAILABLE IN 100' OR 500' WIL LENEiTHS f!:l!TTER SPAC.IN6, 'IN-LINE' EMITTER A I 2"-. 12 O.C,. DRIPTUBIN6 HEADER AND EXHAUST LINES TO DRIP LINE ~~NE SPAC,N6, SHALL !lE PVC, C,L5. 200 SOLVENT /'ELD PIPIN<:> SURFAGE DRIP LINE NOiES, INSTALL MAN/AL LINE FLIJ5HIN& VALVE PER DETAIL f,/2/!J AT LOl'i POINT AND AT END OF EACH 5Y5m1 INSTALL FLIJ5H VALVE PLUMBED ON PVC, EXHAUST HEADER 4 PER MANLfAC,1\IRER'S RECOMMENDATIONS. INSTALL RAINBll<D AIR RELIEF VALVE Af1:!IC150 AT HIIOH POltlT OF EAC,H 5YSm1. INSTALL PER DETAIL E/2/!J AND MAILl'AC,1\IRER'5 REGOMM:NDA110H5. INSTALL DRIPLINE R,(J-Jf. f>l<ADE IN A LINEAR PATTERN TO AVOID PLANTIN6 DISTl.!iBAll(,E, REffR TO LAYOl/l' DErAIW ANCl'OR l'llili 6' l'IIRE SOIL STAPLES AT 4' o.c,, GHAN6E5 IN DtRfC,TION, AND AT ALL PVr, TO POLY FITTIN65 DRIP LINES TO !IE INSTALLED 6" GI.EAR OF PA'i'!Nf>, HAl<D5C,l\ff, GURB EDf>E5 AND GOYERED B'!' 6' OF 6ARK MIA.GI!. DRIPLINE LAll:RAL 5HALL !CT EX(;El:D 260' LINEAR FEET eEMEN pyr, 51-"PLY I EXHAUST HEADERS. INSTALL ttJl!tER EW-ID DRIP OPERATION IHDIC.ATOR MIN. OF ONE PER VALVE SY5m1. IT SHALL !IE PLAC,ED AT TIIE END OF SY5m1 PER DETAIL D/2e,. IHDll:,ATOR TO SHOl'I IF DRIP 15 OPERATINf>, PSI READINf> SHALL !IE RECORDED AT END OF DRIP SYSTEM INSTALLMENT FOR FU11JRE MAIN'IENANCE MONITORINIS. IRRIGATION KEY NOTES EXISTING SFRAY 1-lEADS TO 6E REMOVED AND CONVERTED TO DRIF IRRIGATION SYSTEM. TYPICAL CONTRACTOR TO VERIFY FIFE LAYOUT OF PARKWAY DRIF CI-IANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL An9. EXISTING IRRIGATION VALVE TO 6E REFURFOSED AND REPLACED WITl-l DRIF KIT <PRESSURE REGULATOR, AND FILTER TYF.J CONTRACTOR TO VERIFY VALVE OPERATION LAYOUT OF PARKWAY DRIF CI-IANGES PRIOR TO MODIFICATION REFER TO TYPICAL PARKWAY IRRIGATION DETAIL Ans. ALL IRRIGATION 5Y5TEM5 51-!ALL BE EQUIPPED WITI-! AN AUTOMATIC CONTROLLER CAPABLE OF DUAL OR MULTIPLE PROGRAMMING. CONTROLLER MU5T 1-!AVE NON-VOLATILE MEMORY , MULTIPLE CYCLE 5T ART CAPACITY AND A FLEXIBLE CALENDAR PROGRAM. Tl-IE CONTROLLER 15 TO 5Cl-!EDULE IRRIGATION EVENT5 U5ING EITl-!ER ETO WEATl-!ER BA5ED OR MOISTURE 5EN50R DATA, AND MU5T INCLUDE A RAIN 5EN5ING 51-!UT OFF DEVICE. • IIATCH IIIDICA TES AREA SHOWN ON 11IIS SHEET ICIVIIAP APPRO\/ED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. EX1811N8 32 SFA110N AUl'OMATIC CONTR0U.ER '8' wmt RAIN SENSOR ATTACHED TO BUIL T 11 ..._-I CONTROUER CONTROLLER: GREEN TECH CA1-RBl-32/RSE THE uUGHTFOOT PIANNING GROUP RCE __ _ EXP, ___ _ DATF DESIGNED BY: _E=E~_ DATE: 04/21/2026 DRAWN BY: EE SCALE: I'S INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 I PLANNING 2237 FARADAY AVENUE SUITE 120 CARLSBAD. CA 92008 (760) 692-1924 www.fightfoatpg.com SITE DESIGN LANDSCAPE ARCHITECTURE REVTEwED BY, Ll-11 INSPECTOR DATE 7/08/26 rl-====1====[=============================1====[===]=====c===]-:::::==='===============::::t 6/16/26 I SH1E4ETI I CITY OF CARLSBAD 5/05/26 l----+--+---------------+---+---1---+---I _ PLANNING DIVISION r---::;;;:::::::::::;:::::--,1--=--=--=-t-=--=-1-=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=-j-=.-=.-=-t-=--=-i-=--=--=-1-=--=-j ~==-'===================:::::: I LANDSCAPE IMPROVEMENT PLANS FOR POINSETTIA PROPERTIES (WATERS £ND} IRRIGATION SHEE I I APPROVEDfi~ A. ~ I 1----+---+---------------+---+---+---+---I · <.A,&,U,( '-6,~ 1 l /Df.PA.JME'2 l----+--+----------------+---+----l---l----1 '.::P:::lA:::NN::IN=:G=:::::::::==;-;:=='======::;;:::===~- l--::-=:--t-::-:=,.,.,..-+---------------+---+---1---+---I OWN BY: EE I---DA_TE__.__IN_IT_IAL-+-----------------+...::.D;.:..ATE::...._L.::..CINIT:c;:IA...::.L-1--.::..0A-"JE:__Ll::.C:NITIAL:.c...::..-1 CHKO BY: =JT __ ENGINEER OF WORK Expiration Oote:10/31 /26 REVISION DESCRIPTION OTHER APPROVAL Cl1Y APPROVAL R\IWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-?T II 11A TCH IIIIIICA TES AREA SHO'MI ON TIIS SHEET KmMP ... ~ ' \ \ \ ' \ \ .' ALL IRRIGATION 5Y5TEM5 5!-IALL BE EQUIPPED WIT!-1 AN\ AUTOMATIC CONTROLLER CAPABLE OF DUAL OR MULTIPLE PROGRAMMING. CONTROLLER MUST I-IAVE NON-VOLATILE MEMORY, MULTIPLE CYCLE START CAPACITY AND A FLEXIBLE CALENDAR PROGRAM. Tl-IE CONTROLLER 15 TO 5CI-IEDULE IRRIGATION EVENTS USING EITI-IER ETO WEATI-IER BASED OR MOISTURE 5EN50R DATA, AND MUST INCLUDE A RAIN 5EN5ING 5!-IUT OFF DEVICE. CONTROLJ.ER: GREEN TECH CA'MUll-32/RSE DI RT DIAL TOLL FREE 1-800-422-4133 AT LEAST JWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA EXl8'TINQ POINT OF CONNECTION: 1-V2" WATER METER WITH 1-V2" REDUCED PRESSURE BACKFLOW PREVEN110N DEVICE (POTABLE WATER) IRRIGATION Y NOTES EXISTING SPRA'f !-lEADS TO BE REMOVED AND CONVERTED TO DRIP IRRIGATION SYSTEM. TYPICAL CONTRACTOR TO VERIFY PIPE LAYOUT Of PARK.WAY DRIP C!-lANGES PRIOR TO MODIFICATION REFER TO T'r'PICAL PARKWAY IRRIGATION DETAIL A/29. EXISTING IRRIGATION VALVE TO BE REPURPOSED AND REPLACED WIT!-l DRIP KIT (PRESSURE REGULATOR, AND FILTER TYP) CONTRACTOR TO VERIFY VALVE OPERATION LAYOUT Of PARK.WA'f DRIP C!-lANGES PRIOR TO MODIFICATION REFER TO T'r'PICAL PARK.WA'( IRRIGATION DETAIL A/29. DESIGNED BY: ~E~E __ _ DATE: 04/21/2026 DRAWN BY: EE SCALE: PS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 IRRIGATION EQUIPMENT LEGEND VAL VE5, CONTROLS, 4 MISC. EQUIPMENT DETAIL 5YM. c12e MANUF AG 11JRER / MODEL # RAINBIRV xa-I50-LCS-SERIES REMOTE CONTROL DRIP VALVE i"IITH FILTER 4 PRESSURE RE6ULATOR 5U65UFIFACE DRIP LINE DETAIL SYM. DESGRIPTION RAINBIRD XFD SERIES DRIPPER LINE RAINBIRD XFD-O'l-12 DESC.RIPTION DRIP REMOTE COITTROL VALVE ASSEMBLY CHRISTIES I.P. TA5 FOR STATION NUMBER BRAND eox LID "STA.#" 6PM-AT 40 P5I REMARK 1.54 PER 100' L.F. FLOl'l, o.q ~H ON-SURFACE -J/2 D A/2Gftj AVAILABLE IN 100' OR 500' COIL l.EN5TH5 HEADER AND EXHAUST LINES TO DRIP LINE SHALL 6E PVC CLS. 200 SOLVENT i"IELD PIPIN6 EMITTER SPACINIS, 'IN-LINE' EMITTER 12' O.C. DRIP ilJBIN6 P,!IIP LINE 5PACIN6, 12' o.c. SURFACE DRIP LINE NOTES, INSTALL MANUAL LINE FLUSHIN6 VALVE PER DETAIL 6/25 AT LOi"I POINT AND AT END Of EACH SYSTEM INSTALL FLUSH VALVE PLIJM6ED ON PVC EXHAUST HEADER 4 PER MAtt!FAC'T\JRER'S REWMMENDATION5. INSTALL RAINBIRV AIR RELIEF VALVE ARV050 AT Hl6H POINT OF EACH SYSTEM. INSTALL PER DETAIL E/W AND MANUFAC'T\JRER'S RECOMMENDATIONS. INSTALL DRIPLINE Af30IE 6RADE IN A LINEAR PATTERN TO AVOID PLANTIN6 Dl5'MBANCE. REFER TO LAYOUT DETAIL ANCHOR V<ITH 6" Jl'llRE SOIL STAPLES AT 4' Ot:,., CHAN6E5 IN DIRECTIO~ AND AT ALL PVC TO POLY FlmN65 DRIP LINES TO BE INSTALLED 6" a.EAR OF PAVINIS, HARDSCAPE, CIA<B ED6E5 AND COVERED 61' 9" OF BARK 1-U.CH. DRIPLINE LATERAL SHALL NOT EXCEED 290' LINEAR FEET Bl:Tl"IEEN PVC SLl"PLY 4 EXHAUST HEADERS. INSTALL HUNTER EGO-ID DRIP OPERATION INDICATOR MIN. OF ONE PER VALVE SYSTEM. IT SHALL BE PLACED AT THE END OF SYSTEM PER DETAIL D/28. INDICATOR TO 5HOl"I IF DRIP 15 OPERATINIS. FSI READIN6 SHALL BE RECORVED [i\ F AT END OF DRIP SYSTEM INSTALLMENT FOR AJT\!<E MAINTENANCE MONITORIN6. "&42,0'-x-------,,-------------------------- THE .,. LIGHTFOOT PIANNING GROUP PLANNING ·. -·_: ➔ NOTE: ALL INTERIOR ---.... ~ --~ ~ -----__ ,,,_.-. 2237 FARADAY AVENUE SUITE 120 CARLSBAD,CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE U-12 PROJECT TO BE IRRIGATED USING POTABLE WATER. TYPICAL APPROVED FOR IRR,GATION AND PLANTING ONLY, lf\JCLUUINC; PRFCISE LOCATION OF PLANTING ARr:-A. RCE __ _ EXP, ___ _ DATl R[Vl[\i[D BY, INSPECTOR DATE 1/os/26 i---,--r-------.... ------T-,--r-,--~ 1 :-===~ 1 ======:::::::::::::::::::::;:::::::::::==::::::::;::::::::::;:::::::::::====:::;i 6/16/26 SH1E5ET I CITY OF CARLSBAD 5/05/26 1----+---+-----------------+---t----+---+-----1 _ PLANNING DIVISION :=L=A=N==D=s=c='--Ac'=PE===I==M==P==R==o==VE;::::M==E:;:N==T=P==L;:A==N:;:S~F==o==R=: ======::::; I POINSETTIA PROPERTIES {WATERS END) IRRIGATION SHEET 1----+--+--------------1------+--+--+---1\A-P_P_Ro_\_1E_o_(=.P,-'A=M---J ,,,~,~ _PLANNING ~ 1{{lPl'IUfl DATE DATE INrTIAL ENGINEER OF WORK Ex irclior Date:10/31/26 R[VISION DESCRIPTION DATE INrTIAL DATE INITIAL OTHER APPROVAL CfTY APPROVAL DWN BY: EE CHKD BY: JT RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-?T DIGA MATCtUE SEE Sl&T I.P-3 I--111 -I 111111 , -J , i1 t.__ _ __ / I I ====1J RT ~ ~- ---~ ------------ DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG , I / I UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA 0 fll I !\\ 4 !lJ j I _L_ - I I i ' " • I, '(_ i I I I \ I EXl&TING ei ET 1-+-, ➔ n.l=E& TO l'<EMAIN ·-, . TYPICAL l .- / I ·• [' I I I D : I • : t • I I I I I I I I I I -() ! ~ ,~~-I I ' '7 . ' I -- I I -- I I I I I I t I ' -I -' ! I I ! -' - I I I I I ' \ \ ' \ \ ' \ \ \ \ \ ' \ I I I : I i I I I I I I I i l I I I I I I I I I ):::.. ~ ~ ~ ' \ \~ Q ~ en THE .. LIGHTFOOT PlANNING GROUP PLANNING 2237 FARADAY AVENUE SUITE 120 CARLSBAD.CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE Ill PLANTING LEGEND 5YMElOL ~ ~~-. DESCRIPTION rrF!' CONTAINER/ PET At ..,,ri.v. ,.,..,,.......,.._,. LCMANDRA 'ARCTIC FROST' /ARCTIC HAT RU5H) AND LOW S GAL. x 4' O.C. ~!I IIESFERAI.OEPARV. ~IGHT5'(f'lM(ELIGIIT5!iEDlllCCAIWI™ LOW S GAL. x 4' O.C. El/ 29 tr'':'.":-'-:'"q LANTANA HON. 'FU!sf'LE' (TRAILNG LAMTANA ~El LOW I GAL. x 5' O.C. vvvvv vvvvv vvvvv v_v_v_v_ (i)21 EPIL061U1 CA'i!.11 (CALl'ORNIA AJC!l6IA! 111TH LOW S GAL. x 4' O.C. El / 29 Q) 5ALYIA LEUCANTHA 'SANTA BARBARA' 155. SAclE/ #D LOW 5 GAL. x 4' O.C. @ F105HA\WUS 'PRO&TRAiUS' <CREEPli-1:!, ROSEMARY) LOW I GAL. x f,' O.C. ///// ///// ///// ///// i..r ,.r' ,.r' ,.r' (i)21 r;w Q) F105HARNUS 'f'R06TRA1U5'/CREEPNG R06EHARr/ WI LOW I GAL. X f>' O.C. 6 / 29 Cl51U5 ~T' <MAGENTA ROCl<RO&EJ LOW S GAL. X 48' O.C. LANT,1/;A Mal. 'AJl<A.E' (Jl<AILIII!; LANT,1/;A f'lffl..E/ WI LOW I GAL. X J;' O.C. El / 29 isl-lAP!llot..EPIS INDICA 'PINKIE' /Fil-KIE INDIAN HAWTHORN, LOW S GAL. X 36' O.C &AL VIA 'BEES 6l le&' (BEE'& 6Lle& 5AGEJ WI SAL YIA LEllC.INTHA 'SANTA 6Al<!l,ARA' 156. SAGE/ LOW I GAL. X S' OC.. El / 29 LOW S GAL. X 4' OC.. LANTANA MOO. 'RlmE' (Tf<AILll>k:; LANTANA Rm.El UJ/ LOW I GAL. X J;' O.C. 6 / 29 La-lANDRA 'ARCTIC FROST' ( ARCTIC MAT ~! LOW S GAL. X 4' O.C. PLANTING KEYNOTE& r,:;-:;i EXl5Tlllt:, TUfiif AREAe IN PA!<l<WAY TO 6E REHOYl=D AND FLANTED WITI-I PROPOSED PLANTING. l.::'...'.J TYPICAL r;:;;;! FLANTli-1:!, ALON:; PA!<l<WAY eHALL 6E MAINTAINED AT A MAX OF 3~ INCHES IN I-IEIGHT FOR 51ul-lT ~ DISTANCE. WHICH INCLUDE ElOULDERS. TYPICAL ~ ANY TREE& LOCATED WITHIN A VEHICULAR 5Iul-lT LINE HLIST HAVE ALL LIMElS REMOVED TO A I.'::'..:::! I-IElul-lT OF 6 FEET A60VE THE ADJACENT TOP OF CUREl. TYPICAL NOTE: FOR LAND5CAFE IN5TALLATION5, COMP05T AT A RATE OF A MINIMUM OF FOUR CUBIC Y ARD5 FER 1,000 5QUARE FEET OF PERMEABLE AREA 51-lALL BE INCORPORATED TO A DEFTl-l OF 5IX INC!-lE5 INTO Tl-IE 501L. 501L5 WIT!-l GREATER T!-lAN 6% ORGANIC MATTER IN Tl-IE TOF 6 INCl-lE5 OF SOIL ARE EXEMPT FROM ADDING COMF05T AND TILLING. PRIOR TO PLANTING OF ANY MATERIAL5, COMPACTED SOILS 5!-lALL BE TRAN5FORMED TO A FRIABLE CONDITION. Tl-IE APPLICATION OF ORGANIC MULC!-l MATERIALS MADE FROM RECYCLED OR FOST-CON5UMER MATERIAL5 S!-lALL TAKE PRECEDENCE OYER INORGANIC MATERIALS UNLE55 RECYCLED OR F05T-CONSUMER ORGANIC PRODUCT5 ARE NOT LOCALLY AVAILABLE. A MINIMUM OF 3' OF ORGANIC MULC!-l 5!-lALL BE ADDED IN NON-TURF PLANTING AREA5. ALL EX15TING PLANTING DESIGNATED TO REMAIN ON 51TE 51-lALL BE PROTECTED IN PLACE. ANY EXISTING PLANTING DAMAGED DURING Tl-IE COUR5E OF Tl-IE PROJECT 51-lALL BE REPLACED IN KIND TO Tl-IE SATl5FACTION OF Tl-IE CITY AND FER LAND5CAFE MANUAL REQUIREMENT5. NO EXISTING TREE5 ARE TO BE REMOvED AND 51-lALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION. TYPICAL APPROVED FOR IRRIGATION AND PLANTING iJNI Y, INCLUDINC PI\FCISE LOCAliC)N C)F PLAI\TING AREA. RCF __ _ EXP, ___ _ DATE REVIEwlD BY: LP-1 INSPECTOR DATE 1;as;2s r---i--r--------------T---r--r-,----,r. 1 =:::::::::::::;';I ::::::::::::::::::::::::;::=-====;:::::::::::=:::::::====:::::::==:::;-1 6/16/26 Srl1t6tT I CITY OF CARLSBAD 5/05/26 1-----+--+-------------------+---+---t-----+------1 _ PLANNING DIVISION ,----::::;;:~==::;:::---1, _-_---:__----+t_-_-_---+, _-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_::::__::::__::::__:-::_--::_::-_::---It--_-_---+t ---=--=--1=--=--=--=--~t_::::__::::__~j :=L=AN==D=s=c=--AP;:E===IM=P==R=o==VF:::;:,M:::F:;:,N~'l'=P~T=,A~N:;S ~F:::O~R=: =======:I DESIGNED BY: EE DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 POINSETTIA PROPERTIES (WATERS £ND) PLANTING SI lr,T 1----+---1----------------i---+---+----+-----' ___ _,,<AK/4~='A4-----. _t/,,_,,.',tt-0_~:;--~--'1 l tl.L(Z.IP I AFJPROVED / .I! . -fi _ .,,,- DATE INITIAL ENGINEER OF WORK Exp ira:ion Date:10/31/26 ~EVISICJN DcSC:RIPTiCJN DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL PLANNING DATE OWN BY: EE CHKD BY: JT RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-?T DI AT LEAST TINO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA EXISTING I.AND&cAPE TO REMAIN TYPICAi. EXISTING LAND5CAPE TOl'o!:MAIN TYPICAi. \ \ , / I i/ • -1' ~ I \ ------ ' I - DESIGNED BY: ~EE~-DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 51.3 I 2237 FARADAY AVENUE SUITE 120 CARLSBAD.CA 92008 (760) 692-1924 www.lightfootpg.com Sill' DESIGN LANDSCAPE ARCHITECTURE Ill PLANTING LEGEND IT1160L '"' --~;: DESCRIPTION ~ ,._,.__.._v._.., (D21 iffUW.CE PAR/. IIM<ELIG!!T5' (flAAl(E.IG!!f5 ,ft) lllCCA! lln™ LOW 5 GAL. x 4' 0.C. 6 / 2S G) LOMANDRA 'ARCTIC FR06T' (ARCTIC MAT~) AND LOW 5 GAL x 4' 0.C. vvvvv 111 V VV V ,_vvvvv 11VVVV @ L.WANA MON. 'RIRPLE' /TRAILlt-t. LANTANA RIRPLEJ LOW I GAL x 5' o.c. ~ EFIL06klM CANll1 (CALIFOlsNIA ~SIA/ UITH LOW S GAL. x 4' oc. 6 / 2,1 SALVIA LEUCANTHA 'SANTA BARBARA' /SB.SAGE/~ LOW S GAL x 4' O.C. l<OSMARINU5 'FROSTRATUS' /CREEPING l<05EMAR'r'J LOW I GAL. x b' O.C. K> O IB "x --, X' 21 R05MAR!i'i.15 'FROSTRATUS'(CREEPING f<OSEMAR'(J WI LOW I GAL X b' 0.C. 6 / 2S Cl511JS 'Sl.1>15ET' <MAGENTA F10Cl<ROSE/ LOW 5 GAL. X 48' O.C. / / / / / LANTII-¼ MON. 1'UFiFLE' /TRAILi-i:; LANTII-¼ RlmEJ WI LOW I GAL. X 5' 0.C. 6 / 2S /,,,,,,,, IB~ ~ ~ ~ ~ ~ RllAF!ilOLEF15 INDICA 'Fll<IE' (Fl~IE INDIAN HAWtll@I LOW 5 GAL X %' O.C l::===l (D21 SALVIA 'BEES 6Ll55' /BEE'S BLISS SAGE! WI (I) SALVIA LEUCANTI-IA 'SANTA BAJ;!lARA' rsa SAGE) LOW I GAL X 5' O.C. 6 / 2,1 LOW 5 GAL. X 4' O.C . .i::,-i-_,.r _,.r _,.r IBI ~~/_Is LANTANA MON. 'Rll<FLE' /TRAILi-i:; LANTANA RlmE/ WI LOW I GAL X 5' O.C. 6 / 2,1 ·.r ..r'J .r LOMANDRA 'ARCTIC FROST' ( ARCTIC MAT f<U51.1J LOW S GAL. X 4' 0.C. PLANTING KEYNOTE& r,,:;] EXISTNG TUl,f AREAS IN FA!sKWAY TO BE REMOVED AND Fl.ANTED WITH PROPOSED PLANTING. ~ TYPICAL M PLANTING ALONG PA!sKWAY 5f.lALL BE MAINTAINED AT A MAX OF 30 INCHES IN f.lEIGHT FOR SIGHT ~ DISTANCE. WHICH INCLUDE BOULDERS. TYPICAL ~ ANY TREES LOCATED WITHIN A VEHICULAR SIGHT LINE MUST HAVE ALL LIMBS REMOVED TO A l;:'..::;J f.lEIGI-IT OF E> l'EET A60VE Tl-IE ADJACENT TOP OF CUlsB. TYPICAL NOTE, FOR LANDSCAPE INSTALLATIONS, COMPOST AT A RATE OF A MINIMUM OF FOUR CUBIC YARDS PER I,@@@ SQUARE FEET OF PERMEABLE AREA Sl-lALL BE INCORPORATED TO A DEPTl-l OF SIX INCHES INTO THE SOIL SOILS WITH GREATER THAN 6% ORGANIC MATTER IN Tl-lE TOP 6 INCl-lE5 OF SOIL ARE EXEMPT FROM ADDING COMPOST AND TILLING. PRIOR TO PLANTING OF ANY MATERIALS, COMPACTED SOILS Sl-lALL BE TRAN5FORMED TO A FRIABLE CONDITION. Tl-lE APPLICATION OF ORGANIC MULCl-l MATERIAL& MADE FROM RECYCLED OR PO5T-CON5UMER MATERIAL& 51-lALL TAKE PRECEDENCE OVER INORGANIC MATERIAL& UNLE55 RECYCLED OR PO5T-CON5UMER ORGANIC PRODUCT& ARE NOT LOCALLY AVAILABLE. A MINIMUM OF 3' OF ORGANIC MULCl-l Sl-lALL BE ADDED IN NON-TURF PLANTING AREA&. ALL EXISTING PLANTING DESIGNATED TO REMAIN ON 51TE 51-lALL BE PROTECTED IN PLACE. ANY EXISTING PLANTING DAMAGED DURING Tl-lE COURSE OF Tl-lE PROJECT 51-lALL BE REPLACED IN KIND TO Tl-lE SATl5FACTION OF Tl-lE CITY AND PER LANDSCAPE MANUAL REQUIREMENT&. NO EXISTING TREE& ARE TO BE REMOVED AND 51-lALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION. TYPICAL APPROVED FOR :RRICATiON AND PLANTING ONLY, !NCLUDING PRECISE LOCATION 01 PLANTING AREA. 11 A S B LJ I L T 11 RCE __ _ EXP, ___ _ DATE REVIE'v/ED BY, PLANTING SI l[[T I A,)PROVED / /l. Rt I t---t----+-------------l--+---l----1-----1 __ __,µ'-"'A~-=Ia.,_.d4-1,--,.,_,,,.J~"'-""Ui,.,,/ __ i ( 1l.f{1.l_p 1----+--l----------------+----l-----11------1-----1 PLANNING ~ DATE . :=======:;;;:::=:=:;-;========;~==~I DATE INITIAL ENGINEER OF WORK l:.xpiration Date:10/7!_!/2_? REVISION DC:SCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL OWN BY: ~E~E __ CHKD BY: ~JT __ R'MD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T RT DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA -- \ I -' \..,.I--__. DESIGNED BY: ~EE~_ DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 ' \ \ -' \ -- ' '1 ' ' ' 7/08/26 \ m \ z \ 0 \ -' z \ ~ I ' I / J I f / ---~----/ THE ., LIGHTFOOT PIANNING GROUP PLANNING EXl&TINCi LANDSCAPE TOl'<EMAIN TTPICAL \ \ \ \ I \ 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 \760) 692-1924 www.lightlootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE • PLANTING LEGEND SYMBOL 10 "=' DESCRIPTION '"""' CONT ~lf'!ERI DET All 6PAO•= .,.,,,..,.,_.,...,_, , LOMANDRA 'ARCTIC FROST' /ARCTIC MAT RUS!-1/ AND LOW 5 C:iAL. x 4' O.C. ~3 1 fESFERALCEPARl'.1lR!!la16H15'!a<lm.16H15"8>11lCCAJUI™ LOW 5 C:iAL x 4' O.C. 6129 ~1'::'.:::'.:::':~ LANTANA Mai f\.lRFLE1 (TRAILi~ LANTAl-lA R!Rf'LEJ LOW \ ~AL x 5' O.C. vvvvv vvvvv vvvvv v_v_vv cp EPIL06IUM CAHrl (CALFOl<NIA ru:;HSIAJ WITH LOIIJ 5 C:iAL x 4' O.C. 6 / 29 G) SALVIA LEOCANTHA 'SANTA BA"6ARA' 15.6.SAGE/ AND LOW 5 C:iAL x 4' O.C. (]) ROSMARINi.15 'FR05mAT1JS' /CREEFll'i; i.DSEMART) LOW I C:iAL. x t!>' O.C. Q)2i 1'05MARINU5 'FR051RAT1JS'(CREEPll'I; i.oSEMAl<Y) UV LOW I C:iAL. X 6' O.C. 6 / 29 Q) Cl511JS '5UN5ET' (MAGENTA fiOO<fiiOSE) LOW 5 C:iAL X 46' O.C. ///// ffi' / / / / / LANTANA MCN. Rm£' /TRAILING; LANTANA RIW!.El UV LOW I C:iAL. X 5' O.C. 6 / 29 ~ ~ ~ ~ ~ RI-IAPHIOLEPIS INDICA ,=1t1<IE' IPllll<IE INDIAN LOW 5 C:iAL. X 36' O.C Q)2I SAL VIA 'BEES BUSS' (BEE'S BUSS SAGE) UV l====l G) SAL VIA LEUCANTHA 'SANTA BARBARA' (5£. SAGE) LOW I C:iAL. X 5' O.C. 6 / 29 LOW 5 C:iAL. X 4' O.C. LANTANA MCI'< 'PIIRPLE' (TRAILi~ LANTANA RJRFI.E) 11/1 LOW I C:iAL. X 5' o.c. 6 / 29 LOMANDRA 'ARCTIC FROST' (ARCTIC MAT~) LOW 5 C:iAL. X 4' O.C. PLANTING KEYNOTES ~ EXISTINC:i TURF AREAS IN PARKWAY TO BE REMOVED AND PLANTED WIT!-< FROFOSED FLANTll'i;_ ~ TYPICAL r,:;-;;J FLANTINC:i ALONC:i FAl<KWAY 61-<AUL 6E MAINTAINED AT A MAX OF 3" INC!-<ES IN 1-<EIC:il-lT FOR SIC:iHT l::=:J DISTANCE. WHICH INCLUDE 60LILDER6. TYPICAL ~ ANY TREES LOCATED WITHIN A VEHICULAR 61C:iflT LINE MUST HAYE ALL LIMBS REMOVED TO A 1::.:::1 HEIC:iHT OF & FEET ABOVE THE ADJACENT TOP OF CURB. TYPICAL NOTE, FOR LANDSCAPE IN5TALLATION5, COMPOST AT A RATE OF A MINIMUM OF FOUR CUBIC , ARD5 PER l,001Zl 5QUARE FEET OF PERMEABLE AREA 51-JALL BE INCORPORATED TO A DEPTI-J OF 5IX INCI-JE5 INTO Tl-lE 5OIL 50IL5 WITI-J GREATER Tl-JAN 6% ORGANIC MATTER IN Tl-IE TOP 6 INCI-JE5 OF 5OIL ARE EXEMPT FROM ADDING COMPO5T AND TILLING. PRIOR TO PLANTING OF AN, MATERIAL$, COMPACTED 5OIL5 51-JALL BE TRANSFORMED TO A FRIABLE CONDITION. TI-JE APPLICATION OF ORGANIC MULCl-l MATERIALS MADE FROM REC,CLED OR PO5T-CON5UMER MATERIALS 51-JALL TAKE PRECEDENCE OVER INORGANIC MATERIALS UNLE55 REC,CLED OR PO5T-CON5UMER ORGANIC PRODUCTS ARE NOT LOCALL 1 AVAILABLE. A MINIMUM OF 3' OF ORGANIC MULCl-l 51-JALL BE ADDED IN NON-TURF PLANTING AREA5. ALL EXISTING PLANTING DESIGNATED TO REMAIN ON 5ITE 51-JALL BE PROTECTED IN PLACE. AN, EXISTING PLANTING DAMAGED DURING TI-JE COUR5E OF TI-JE PROJECT 51-JALL BE REPLACED IN KIND TO TI-JE 5ATl5FACTION OF TI-JE CIT, AND PER LANDSCAPE MANUAL REQUIREMENTS. NO EXISTING TREE5 ARE TO BE REMOVED AND 51-JALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION. T,PICAL APPRO\JED FOR IRRIGAT ON AND PLANTING ONI_ Y, INCLUDING PRECISE HA Teti IIIDICA TES I OC~A.TION OF PLA,NTING ARE,~. AREA SIIOWM ON TIIS SHEET 11 A S B U I L T 11 RCE __ _ EX"----- R[Vl[\./[D llY Ll-3 INSPlCIIJR DATF DATE 6/' 6/26 l---+------+------------+--+------11-----1------1 I SH1E8ET 11 CITY OF C i\RLS BAD 5/05/26 t-----+--+-----------------+-----+--t----+------1 . PLANNING DIVISION ,---::::;;:~~;::::---1_1 _-_-_-_--+t _-_-_-_-+-I_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-➔t_-_-_-_-+-t _-_-_--~I_-_-_-_-+-I_-_-_--.i '=L=AN=Tl=s=c='-A P'=E=, =1M=P=R=o=VE=M=E=N=T=P=L=A=N=s =F=o=R=: ======:I POINSETTIA PROPERTIES {WATERS ENO) Pl ANTING SHEET \ APPROVED/~ /4 l-----+--+----------------+----+---1------+--__. ~-"1 ~ .. l-----+--+----------------+----+---1------+--__. PLANNING I DATE DATE INITIAL ENGINEER OF WORK Expiration Date:10/31/26 DATE INITIAL DATE INITIAL RI:. VISION DESCRIPTION OTHER APPROVAL CITY APPROVAL ;:::::::::==:==;;;:::==;-;========;;====;1 OWN BY: EE CHKD BY: ~JT __ RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-?T DI RT DIAL TOLL FREE 1-800-422-4133 AT LEAST lWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA \ \ DESIGNED fJY:)---'E"'--E __ DATE: 04/21/2026 DRAWN BY: IEE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 7:,,, EXl&TING &TR:ET Tl'<EES TO ~AIN TYPICAL ' THE -::::::)jEi~II'-~-~--LIGHTFOOT _. _ PIANNING GROUP PLANNING 2237 FARADAY AVENUE SUITE 120 CARLSBAD.CA 92008 1760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE PLANTING LEGEND SYMBOL ~IN: DESCRIPTION ,,., __ , • C::f'NTAINER/ bET All 5,-,ACING ~: IE5FERAI.OE P/il>I. llAA'(Elk,HIS' /em:El.lGHT5 J,ED YOCCA/ Ul1H LOW 5 GAL. x 4' 0£. 6 / 29 µ.,-'-,.-'..-Yvl LOMANDRA 'ARCTIC FROST' /ARCTIC MAT 1'!11514) AND LOW 5 GAL. x 4' O.C. ::':;-'::':;:'~ L/INTANA l1Ctl 'FUl<FLE' /TRAILll'I'.; LANTANA F'Ui<FLEJ LOW I GAL. x 5' O.C. vvvvv 17VVVV vvvvv 17VVVV CD2 EPIL06I111 CAtU1 /CALFOJ<NIA !UCl-15IAJ 111114 LOW 5 GAL. x 4' o.c. 6 / 29 G) 5Al.VIA LEUCANTHA 'SANTA 6AFi6,<1RA' /5.6. SA(lf/ AND LOW 5 GAL. x 4' O.C. @ R05MARIN\J5 'PR05TRATU5' /CREEPING ROSE11ARYJ LOW I GAL. x 6' O.C. R05MARIM.IS 'PROSTRAl\15'/CREEPINGi R05EMARYJ UI/ LOW I GAL. X 6' O.C. 6 / 29 CISTU5 'SUN5ET' /MAGENTA ROC:Kls05EJ LOW 5 GAL. X 48' O.C. LANTANA MON. ~E' ITRAIUr-t; LANTANA RJl<PLEJ WI LOW I c;AL. X 5' O.C. 6 / 29 RHAPHIOl.~5 INDICA 'Plll<IE' /PH<IE INDIAN HAW™Ol<N LOW 5 c;AL. X 3h' O.C (i)2I SALVIA '6EE5 BLISS' /BEE'S BLISS SAc;EJ UI/ LOW IGAL.X5'O.C. 6/29 (J) SAL VIA LEUCll!tAA 'SANT A 6Als!lARA' /SB. 5AtlEJ LOW 5 GAL. X 4' O.C. LANTANA MON. 'Flm.E' ITRAILlr,t; LANTANA FU!sPLEJ WI LOW I GAL. X 5' O.C. 6 / 29 LOMANDRA 'ARCTIC FROST' ( ARCTIC MAT Rl.15H) LOW 5 GAL. X 4' O.C. PLANTING KEYNOTES r;:;-:;, EXISTING TUl<f AREAS IN PARKWAY TO 6E REMOVED AND A-ANTED WITH PROPOSED A-ANTIN5. l.::'.!J TYPICAL r,:;;:;) A-ANTIN5 ALCN:;; PARKWAY SliALL 6E MAINTAINED AT A MAX OF 30 INCHES IN HEIGHT FOR SIGHT ~ DIST ANGE. WHICH INCLUDE BOULDERS. TYPICAL r,:,:;J ANY TREES LOCATED WITHIN A VEHICULAR SIGHT LINE MUST i-lAYE ALL LIM65 REMOVED TO A l::'.:::J HEIGHT OF 6 FEET A60VE THE ADJACENT TOP OF CUREl. TYPICAL NOTE: FOR LAND5CAFE INSTALLATIONS, COMPOST AT A RATE OF A MINIMUM OF FOUR CUBIC YARDS FER 1,000 SQUARE FEET OF PERMEABLE AREA SI-IALL BE INCORPORATED TO A DEFTI-I oF SIX INCI-IES INTO Tl-IE SOIL SOILS WITI-I GREATER TI-IAN 6% ORGANIC MATTER IN Tl-lE TOF b INCl-lES oF SOIL ARE EXEMPT FROM ADDING COMPOST AND TILLING. PRIOR TO PLANTING oF ANY MATERIALS, COMPACTED SOILS Sl-lALL BE TRANSFORMED TO A FRIABLE CONDITION. Tl-lE AFFLICATION oF ORGANIC MULCI-I MATERIALS MADE FROM RECYCLED OR POST-CONSUMER MATERIALS SI-IALL TAKE PRECEDENCE OVER INORGANIC MATERIALS UNLESS RECYCLED OR POST-CONSUMER ORGANIC PRODUCTS ARE NOT LOCALLY AVAILABLE. A MINIMUM oF 3' OF ORGANIC MULCI-I SI-IALL BE ADDED IN NON-TURF PLANTING AREAS. ALL EXISTING PLANTING DESIGNATED TO REMAIN ON SITE SI-IALL BE PROTECTED IN PLACE. ANY EXISTING PLANTING DAMAGED DURING Tl-IE COURSE oF Tl-IE PROJECT SI-IALL BE REPLACED IN KIND TO Tl-IE SATISFACTION oF Tl-lE CITY AND FER LANDSCAPE MANUAL REQUIREMENTS. NO EXISTING TREES ARE TO BE REMOVED AND 51-lALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION. TYPICAL ' . C I c_JL.I!\ I • ~~-L HATCH IIIIIICA AREA SffO'MI -._.. ~ 11tS SHEET IK!?I# LJ APPROVED FOR IRRIGATIO.N ANO PLANTING ONLY, INCLUDING PR~CISL LOCATION OF rLAN IING AREA. 11 A S B U I L 1 11 RCE __ _ EXP. __ _ DATE REVIE\/[D BY, LP 4 INSPECTOR DATE i/0B/26 ,-,-,--------------,--,-,---,-----y-===============================:I 6/16/26 l---+---1-----------------if---+---+-----+----cl I SH1E9ET 11 CITY OF C i\.RLS BAD 5/05/26 . PLANNING DIVISION r ------:~:::::.=::::---t1--=--=--=-t-=--=-1-=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=-~t-=--=-t-=--=-j-=--=--=-1-=--=-j ~====-================~I LANDSCAPE IMPROVEMENT PLANS FOR: POINSETTIA PROPERTIES (WATERS £ND} PLANTING SHEET 1------+-----!---------------+-----+-----l----l---' APPROVED --~~&::L__fd,l,d,,i'l~-~ 1 I a, (iv 1------+-----!---------------+-----+-----l---+---I '.=~P=lA=N_N=:_IN=G---=---=---=--=--=---=-=;-=±=======:;::==DA=TE=~I l--=-c=-+-c=---!---------------+---+----l---+-----cl DWN BY: -'c',EE~_ 1_D_AT_E___.__INIT_IAL--1-----------------l---"D'-"AT.=_E -1...c.clNIT__:_IAL_::___+-----=-cDA-'-=JE'----'--"-INc_:_ITl:_c:AL'--I CHKD BY: =JT __ ENGINEER OF WORK Fxpi:ation Date:10/31/26 REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T DI RT DIAL TOLL FREE 1 -800 -422 -4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA ' ' EXISTING &~ET ~ES TO F<EMAIN TYPICAL \ \ \ DESIGNED BY: ~EE~_ DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 I THE .,. LIGHTFOOT PIANNING GROUP PLANNING \ 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 1760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE • PLANTING LEGEND 5TM80L " ~=• DE6CRIPTION """ T I ' ' vvvvv ivvvvv• vvvvv IO'VVVV ///,I/ /,//,// ///// ,/,//// ~ ~ ffi ffi ffi ffi IE5ftRALIE P/JR/. tll<lmlGIITS' reR.<ll<EI.IGll15 ~ 'l'llCCA)Wffil LOMANDRA 'ARCTIC FR05T' (ARCTIC MAT F<USHJ AND LANT ANA MON. 'FUl<FLE' (TRAILII-I':; LANT ANA FURFLEJ EPILO!llUM CANUM (CAL\fOliNIA FUCl45IA/ WI™ &ALVIA LEOCANTI-IA '&ANJA 6AR6Al<A' (5.6. 5AC,El AND ROSMARINJ5 'FROSTRA11l5' (CREEf'it-1':; ROSEMARf/ ROSMARlr-1.JS 'FROSTRA11l5'(CREEFIN-:; ROSEMARY! WI Cl51\J5 '51.N5ET' /MAGENTA .oo<FiOSE/ LANT ANA MON. 'RJRFI.E' rTRAILl-15 LANTANA RJRFLE/ WI RMAPHIOLEFl5 INDICA 'PINKIE' (PIIKIE INDIAN I-IAII/I~ SALVIA '6EE5 6Ll55' (6EE'S 6Ll55 SAGE/WI SALVIA LEOCANT~ 'SANTA 6ARBARA' (S.B. SAGE/ LANTANA MON. T'Ul<Pl.E' (Tl<AILIN-:; LANTANA RJFIF'LEJ WI Lct'IANDRA 'ARCTIC FROST' (ARCTIC MAT FcUSl-lJ PLANTING KEYNOTES IWCOL! CONTAINER/ ~ET AIL ""'ACING LOW S GAL. x 4' O.C. 6 / 2~ LOW S GAL. x 4' O.C. LOW I GAL. x S' O.C. LOW S GAL. x 4' O.C. 6 /2~ LOW S GAL. x 4' 0.C. LOW I GAL. x 6' O.C. LOW I GAL. X 6' O.C. 6/2~ LOW S GAL. X 4&' OC. LOW I GAL. X S' O.C. 6 / 29 LOW S GAL. X 36' O.C LOW I GAL. X S' OC. 6129 LOW S GAL. X 4' OC. LOW I GAL. X S' O.C. 6129 LOW S GAL. X 4' OC. fn:;J EXl5Tlt-l':; 11.llsf AREAS IN PAl<KWAY TO 6E REMOVED AND PLANTED WITI-I FROF05ED PLANTING. L':'...'..I TYPICAL r;:;:;:;] PLANTING ALONG FAlsl<WAY ~ALL 6E MAINTAINED AT A MAX OF 31!l 1~5 IN ~IGI-IT FOR 51GI-/T ~ D15TANCE. ll.!41CH INCLUDE 60ULDER5. TYPICAL r;:;-:,J ANY TREES LOCATED WITI-IIN A VEl-llCULAR 51Gi-lT LINE MU5T 1-lAVE ALL LIM65 REMOVED TO A ~ ~IGI-IT OF 6 FEET A60VE T~ ADJACENT TOP OF CUR6. TYPICAL NOTE, FOR LANDSCAPE IN5TALLATION5, COMFO5T AT A RATE OF A MINIMUM OF FOUR CUBIC Y ARD5 FER l,01Zl1Zl 5QUARE FEET OF PERMEABLE AREA 5HALL BE INCORPORATED TO A DEPTH OF 51X INCHE5 INTO THE 5O1L. 5OIL5 WITH GREATER THAN 6% ORGANIC MATTER IN THE TOP 6 INCHE5 OF 5O1L ARE EXEMPT FROM ADDING COMFO5T AND TILLING. PRIOR TO PLANTING OF ANY MATERIAL5, COMPACTED 501L5 5HALL BE TRAN5FORMED TO A FRIABLE CONDITION. THE APPLICATION OF ORGANIC MULCH MATERIAL5 MADE FROM RECYCLED OR FO5T-CON5UMER MATERIAL& 5HALL TAKE PRECEDENCE OVER INORGANIC MATERIAL5 UNLE55 RECYCLED OR FO5T-CON5UMER ORGANIC FRODUCT5 ARE NOT LOCALLY AVAILABLE. A MINIMUM OF 3' OF ORGANIC MULCH 5HALL BE ADDED IN NON-TURF PLANTING AREA5. ALL EX15TING PLANTING DE51GNATED TO REMAIN ON 51TE 5HALL BE PROTECTED IN PLACE. ANY EX15TING PLANTING DAMAGED DURING THE COUR5E OF THE PROJECT 5HALL BE REPLACED IN KIND TO THE 5AT15FACTION OF THE CITY AND FER LAND5CAFE MANUAL REQUIREMENT5. NO EX15TING TREE5 ARE TO BE REMOVED AND 5HALL BE PROTECTED FROM DAMAGE DURING CON5TRUCTION. TYPICAL I 1 APPRO'✓ED FOR IRRIGATION AND PLANTING ONLY, INC] UDING PRECISE LOCfa,TION Or PLANTING AR~-A._ RCE __ _ EXP. __ _ DATE R[Vl[wED BY= DATE LP-5 INSPECTUI./ 1/os/26 r-,-,---------------r----r--r-1----r-::=::::::::-:::::::;,;:::::::::::~:::::::::::::::::::::::::;::::::::::::;:::::::::::::::::==:::::==:::::;1 6/16/26 SHE_ET I CITY OF CARLSBAD I I 1----+----,t-----------------+---+--t-----+----'I 2(1 5 05 26 , PLANNING DIVISION ,---=~~~;::----t====t===j============================j====t===j====j====i :=L=AN=D=s=cA'...,'P::::E=I:::::M:::P:::::RO==VE====M:::::EN==T====PL=AN====s ::::F==o==R:=====:::::;i POINSETTIA PROPERTIES (WATERS £ND) PLANTING SHEET I APPROVED/~ /J, . ;J_ I -----------------+---+---+----+----t -----=-~--'-"-~~,n~,.,.'d,-utJ<.ee.=,,__,.,.~_ 1 / 1u(Up t-----+----t---------------+----+---1---+----t ;::P::::LAN::::N::IN::::G =::::::::::=::;-;::::='=======;-;:==DA=JE=:::::;·i OWN BY: ~E~E __ DATE INITIAL ENGINEER OF WORK Fxpirntion r)ote:10/31/26 REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL CHKD BY: =JT __ RVWD BY: PROJECT ND. LPC2026-0014, CT000016 DRAWING NO. 396-7T \ \ \ \ \ \ \ DI \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ' \ \ RT \ DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG \ UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ' \ \ \ \ \ \ \ \ \ \ \ \ \ \ EXl!TING LANDecAPE TOIEMAIN TYPICAL SIGHT DISTANCE LINE TYPICAL EXISTING !TIEET TIEES TO REMAIN TYPICAL ,=-, f--~ . i • \ (~~~, ' ~ l. L_/ ' ~ ~ ' j ~ ' 52. 4 i \ \ \ - PLANTING LEGEND 'T11BOL R.ANT DESCRIPTION ffi IESA:RALOE P~-'6i<AKELlllHl5' ll!R.lmlllHl5 l<ED rOCCA/ Ul1H LOW !; GAL. x 4' OC. 6 / 29 LOMANDRA 'ARCTIC FR05T' (ARCTIC MAT RU&HJ AND LOW !', GAL. x 4' O.C. Q) LANT ANA MON. 'FURPLE' (TRAILING LANT ANA FUl<F'LE! LOW I GAL. x !',' O.C. vv vvv ffi fPILO!llLM CANltl /CALIFOFiNIA ~IA! WITH LOW & GAL. x 4' OC. 6 / 29 vv vv vv vvv 5AL VIA LEUCANTHA 'SANTA BAl<BARA' /$ll. 5,l,6E) AND LOW S GAL. x 4' 0£. vv vv Q) R06MARINUS 'FR05TRATU5' (CREEPING R05EMARYJ LOW I GAL. x 6' OC. ' ' ' ~"'~~['-~ ~ '·-ffi R05MARINU5 'F'R05TRATU5'(CREEPING ROSEMARY! WI LOW I GAL. X E>' OC. 6/29 Cl5TU5 'SUNStr (MAOOITA ROCKROSE! LOW & GAL. X 48' O.C. // /// ffi // /// LANTANA MON. 'RJRFLE' (TRAILING LANTANA FIJRFI.EJ WI LOW I GAL X S' OC. 6 /29 // /// ~AFI-IIOLEFIS INDICA ~NKIE' /Fli'l<:IE INDIAN i<A\1/1 LOW S GAL. X 3E>' O.C // /// \ \ ffi SALVIA BEES 6Ll55' 16EE'S 6Ll55 SAGEJ UV LOW I GAL. X S' OC. 6 / 29 &Al. VIA LEUCANTHA 'SANTA 6Al<6ARA' (5!l. 5,l,6EJ LOW S GAL. X 4' O.C. ✓-~ { (i)21 LANTANA MON. 'Rffl.E'/TRAILl~LANTANARR'LEJWI LOW I GAL. X &' OC. 6129 ~ ~ r• r r, Q) La1ANDRA 'ARCTIC FROST' /ARCTIC MAT RUSHJ LOW & GAL. X 4' OC. \ ( R 7 ,,__'l ....... , \,_,/ .r / ------- \ \ l ,~~·-~J \ \ ~ ,,.,--=;-- •5~ · -4 J ~ ~-.l \\..--~- .~--~-- PLANTING KEYNOTES r,:;-:;i EX15TIN<'.:I TlJl,!F AREAS IN PAJ;!<IIJAY TO 6E REMO® AND Ft.ANTED Wlrn FROP05ED FLANTINCil. ~ TYPICAL r,::;-;;f PLANTING ALONG PARKWAY &HALL 6E MAINTAINED AT A MAX OF 312) INCHE5 IN H:IGHT FOR SIGHT l'.::.'.:J DISTANCE. W-IICH INCLUDE 60UI.DERS. TYPICAL r;:;-::;J ANY TREE5 LOCATED WITHIN A VEHICULAR 51GHT LINE MUST +.AVE ALL LIM65 REMOVED TO A ~ +.EIGHT OF E> FEET ABOVE T+.E ADJACENT TOP OF CUR!l. TYPICAL REFER TO SHEET LP-7 ADDITIONAL NOTES. FOR ~~, __ ' ...... " .... _ ... , ... "'-...._ .>-\ ·,"--... ~ ........ -..------, ~ I -• t' 7S ''I "'-~~~~.... \,.... , APPRO\/ED coR I.RRICATION ,""ND PLAN Tl NG O~L Y, INCLUDING PRECISE LOCATION OF PLANTING AREA. ==•==== THE I .,. LIGHTFOOT _. PLANNING GROUP PLANNING 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE // A s B u I I I I/ RCE __ _ EXP. __ _ DATE REV!EwED BY• LP-6 INSPECTOR DA I l 7/08/26 r1-====+===~=============================c===1====c===J===:.i1-::==-!-:=.========================I 6/16/26 ISH2E1ETII CITY OF CARLSBl'I.D 5/D5/26 t---+----1---------------l----l---f----1----1 . PLANNING DIVISION ,----:::;;;::=:=::;:::----~====t===j=============================t===i====t===j===j ~L=AN=D=s=cA~P=E=, =1M=P=Ro=VF:=,=,M=IcN=T'f'=PL=A=N=s=F=o=R=, =====:;I DESIGNED BY: -'=EE~-DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 POINSETTIA PROPERTIES {WATERS ENO} PLANTING SI l[ET l---+--+--------------+-----+---l------+---11 APPROVED 4).-tq /1~ l----+---1---------------1----l--___j __ _J_ _ __J . PLANNING fb , 1 / tu/u., DATE DATE INITIAL I I ENGINEER OF WORK b iration Datc:10 31 26 REVISION DESCRIPTION DATE INITIAL OTHER APPROVAL DATE INITIAL CITY APPROVAL DWN BY: EE CHKD BY: =JT __ RVWD BY, PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T DI AT LEAST TWO DAYS BEFORE YOU D!G UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA \ ' - \ t-- -- ' \'._ • ··s< ,.,,, \ \ \ \ I \ leMAIN !CAL \ \ EXISTING STIIIEET TIIIEESTO!eMAIN TYPICAL DESIGNED BY: ~EE~--DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 I THE .. LIGHTFOOT PIANNING GROUP PLANNING SIGI-IT DISTANCE LINE TYPICAL ~ \ ' \ m z \ \ \ -0 ')> 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 {760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE FL.ANTING LEGEND ~rMeOL ~ DESCRIPTION ilwcoLI <;01!.<lil'IER/ DETAIi I as 0) I I I vvvvv 3s1 !vvvvv vvvvv ;,,v_v_v_v @ " "' ><">< (D21 X O<XX Q) ///// ///// ///// ///// IB IIE5FERALCE FIR-I. llRl1<EL~ llil1li<l:LIGll!5 .!:D Y0CCAJ um! LOW LCl1ANDlsA 'ARCTIC fROST' /ARCTIC MAT~) AND LOW LANTANA Mctl 'F\.IRFLE' (TRAILING LANTANA F\.IRFLEJ LOW EPILOOlll"I CAt-111 /CALFO!iNIA rl.OlSIAi WIT~ LOW SALVIA LEUCANTllA ~A ElARBARA' (55. 5.11:le) AND LOW ROSMARNJS 'PR05TRATIJ5' /CREEPll'l:ir ROSEMARY) LOW !', GAL x 4' O.C. 6 / 29 5 GAL x 4' O.C. I GAL. x !',' O.C. !; GAL. x 4' O.C. 6 / 29 5 GAL. x 4' O.C. I GAL. x 6' O.C. R05MARINU5 'PR05TRATU5'/CREEPING ROSEMARY! WI LOW I GAL. X 6' O.C~, 6 /29 Cl51115 '5ltl5ET' /MAGfNTA 1'10Cl<!<05EJ LOW S GAL. X 48' 01.. LANTANA MON. 'Rm.E' /IRAILll'l:ir LANTANA Rffl.EJ IJJ/ LOW I GAL.XS' O.C. 6 / 29 RllAFHIOLEPl5 8'1DICA 'FN<IE' /PINKIE 8'1DIAN 1-lAWT~ LOW S GAL. X 36' O.C '-===I (D21 SALVIA 'BEES 61.155' /BEE'S 6Ll55 SAGEi WI t-Q) 5AL VIA LEUCAIIT~A 'SANTA ElAR!!ARA' /55. 5.11:le) LOW I GAL X !',' O.C. 6 / 29 LOW S GAL. X 4' O.C. LANTANA MON. 'FlffiE' /TRAILi+::. LANTANA AJRPLEI IJJ/ LOW I GAL. X !;' O.C. 6 / 29 LCl1ANDRA 'Al<CTIC FROST' /Al<CTIC MAT f<U5HJ LOW !:> GAL. X 4' O.C. FL.ANTING KE1NOTE5 r;:;-:,] EXISTING TUFif AREAS IN PARKWAT TO BE REMOVED AND PLANTED WITH PROPOSED PLANTING. l:'_'_I rTFICAL i;;-;:;J PLANTING ALONG PAf,,Kf!JAY Sf.lALL BE MAINTAINED AT A MAX OF 3J!) IN~E5 IN l-!Ef61.iT FOFi! 5ICil-lT ~ DISTANCE. ILi-ii~ INCLUDE BCUI.DERS. TTPICAL fn::;J ANY TF:!:E5 LOCATED WITHIN A VEHICULAR 5lul-lT LINE MUST HAVE ALL LIM65 REMOVED TO A ~ HEICil-lT OF 6 FEET AflOYE THE ADJACENT TOP OF CURB. TTPICAL NOTE, FOR LANDSCAPE INSTALLATIONS, COMPOST AT A RATE OF A MINIMUM OF FOUR CUBIC YARDS FER l,@IZ'IZ' SQUARE FEET OF PERMEABLE AREA Sl-lALL BE INCORPORATED TO A DEFTl-l OF SIX INCi-JES INTO Tl-lE SOIL. SOILS WITl-l GREATER Tl-JAN 6% ORGANIC MATTER IN Tl-lE TOP b INCi-JES OF SOIL ARE EXEMPT FROM ADDING COMPOST AND TILLING. PRIOR TO PLANTING OF ANY MATERIALS, COMPACTED SOILS Sl-lALL BE TRANSFORMED TO A FRIABLE CONDITION. Tl-lE APPLICATION OF ORGANIC MULCl-l MATERIALS MADE FROM RECYCLED OR POST-CONSUMER MATERIALS Sl-lALL TAKE PRECEDENCE OVER INORGANIC MATERIALS UNLESS RECYCLED OR POST-CONSUMER ORGANIC PRODUCTS ARE NOT LOCALLY AVAILABLE. A MINIMUM OF 3' OF ORGANIC MULCl-l Sl-lALL BE ADDED IN NON-TURF PLANTING AREAS. ALL EXISTING PLANTING DESIGNATED TO REMAIN ON SITE Sl-lALL BE PROTECTED IN PLACE. ANY EXISTING PLANTING DAMAGED DURING Tl-lE COURSE OF Tl-lE PROJECT Sl-lALL BE REPLACED IN KIND TO Tl-lE SATISFACTION OF Tl-lE CITY AND FER LANDSCAPE MANUAL REQUIREMENTS. NO EXISTING TREES ARE TO BE REMOVED AND Sl-lALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION. TYPICAL LP-7 APPROVED F01R IRRIGATIO~~ AND PL/\NTING ONI Y, INCLUDING PRLCISE LOCATION OF PLANTING ARE/\. RC[ __ _ lXf-', ___ _ JAT[ REVJF\vFD BY, INSPECTOR DAil 7/08/26 ,----,------.------------------,----,----.-----,----,,-----...L.;_c..._.;;. ___ ;;;;.._;;.._.,;;,_;;.. ____ ~_-_-_-_-_-~~----_-_-_-_-_-_-_-_-_-_-_-_-_-~__:i 6/16/26 I SH2E2ETI I CITY OF CARLSBAD o/05/26 l---l---+-----------------1--__j---+----I----I . PLANNING DIVISION r---:::~==:::;:::------i-1---_ -_-_-_II--_-_-_-_ t+--_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_-_-_ -_ -_-_ -_ -_ -_ -_ -_ -_ -_ -_ i-1 -_ -_ -_ -_ i-1 -_ -_ -_-_-_II--_-_-_-_ i-1 -_ -_-_ -_ i-1 :::T.=A==ND::::s=c=A~P==E==IM:::P::R::O=VE===M==E=N=T=P=L=A=N=s=F==o==R=: ======::: POINSETTIA PROPERTIES (WATERS £ND) PLANTING SHEET l---l-----1---------------4---1---1---1-----II APPROVED~ . ~ . PLANNING f/ '1 I l(fj1.lf DATE DATE INITIAL ENGINEER OF WORK Fxpirotion [)ote:10/31/26 REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL OWN BY: ~EE~_ CHKD BY, =JT __ RVWD BY, PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T \ \ \ \ \ DI \ \ \ RT DIAL TOLL FREE 1-800-422-4133 AT LEAST nN'O DAYS BEFORE YOU DIG EXISTING LANPSCAFE TOFiEMAIN TYPICAL • 1 6,ri~:\ l 51. • ,,'/ / i I ////;/ . ///1, ·;,1,/ • I I :' ' , .. \ \ I - __.\,.__\(Jc,_'~-\ UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA \ \ \ \ \ \ \~ > \ \ ,./4's ~; c.b""~ \ DESIGNED BY: --="EE~-DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 __.._ t:.' ,,,.,.-\ ''(. ( I '-'-• .., I /_. / . ~--_ _.,,,/ / ti§J1 ) ;.. r•-··· -....-"!'" i • -...:..-..:__; I r ~--------../ I .,.____ . .--. \ \ \ I - EXISTING 5TIEEET TIEEES TO F.EMAIN TYPICAL ----- \ '.;. \ ------- \'-.,. ---. ....._ THE ... LIGHTFOOT PLANNING GROUP PIANNING 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 {760) 692-1924 www.lightfootpg.com SITE DESIGN IANOSCAPE ARCHITECTURE PLANTING LEGEND 'f'MSOL FVNT DESCRIPTION ETAI IB 1£5A:RAI.OE PAR-I. llRAKELkil<15' /Jll<IJ(EIX,1!15 RED YIWJ UlllH LOW S GAL x 4' OC. 6 / 29 LOMANDRA 'ARCTIC FROeT' (AlsCTIC MAT "1J51.1! AND LOW S GAL. x 4' OC. @ LAtl!ANA MON. 'RJRPLE' /TRAILING LANTANA FURFLE! LOW I GAL. X S' o.c. vvvvv IB EALOBlll1 CAlitl /CALFOFiNIA FUCHSlA! WITH LOW 5 GAL. x 4' OC . 6/~ vvvv !',ALVIA LEIJCANTHA '5;NTA ~• (5.6. 5AGI:) A"iD LOW 5 GAL. x 4' oc. vvvvv vvvv @ ROSMAl<INUS 'ffiOSTRATU5' (CR!:EP!Nu ROSEMARY! LOW I GAL. x 6' oc. ffi ROSMARINU5 1"!s06TRATU5'(CREEFING ROSEMARY! WI LOW I GAL X 6' OC. 6 / 29 CISl\l& 'SI.INSET' /MAGl:NTA IIOCKR05EJ LOW S GAL. X 48' OC ///// ffi L;NT ANA MON. 'RIRPLE' /TRAILINu LANT ANA RIRPI.El Ill/ ///// LOW I GAL. X 5' OC. 6 / 29 ///// RJ-!APHIOLEPIS U'OICA 'Plll<IE' (Plll<IE INDIAN l!Allll LOW S GAL. X 36' OC ///// (i)21 SALVIA l:ll:ES BLISS' <eEE'S BLISS SAG.El WI G) SALVIA LEll::AlllllA 'SANTA BAR6ARA' /S.6. SAGE! LOW I GAL. X 5' OC. 6 / 29 LOW S GAL. X 4' OC. (i)21 LANTANA MON. f'lm_E' ITRAILll't. LANTANA RJRFLE! W/ LOW I GAL. X :,' O.C. 6 / 2~ ,.. ,... ,,.. ,.. ,,.., G) LOMANDRA 'ARCTIC FROST' (Al<CTIC MAT R\.ISl1! LOW 5 GAL. X 4' O.C. PLANTING KEYNOTES r,:;-:;i EXIST\l,I'.; TURF AREAS IN PARKUIAT TO BE REMOYED AND PLANTED WITI-I PROPOSED PLANTll«::I. ~ TTPICAL r,:;;;J PLANTING ALON:. PAl-l<WAT 51-iALL BE MAINTAINED AT A MAX OF 31Z' INCl-ll:5 IN I-IEIG,I-IT FOR 51fil1T ~ DISTANCE. ll.l-llCI-I INCLLIDE BOULDERS. TYPICAL ~ ANT TREES LOCATED WITHIN A YEI-IICULAR SIG,I-IT LINE MU5T I-IAYE ALL LIMBS REMOVED TO A l:'..::::l I-IEIG,I-IT OF 6 FEET A60YE Tl-IE ADJACENT TOP OF CURB. TYPICAL NOTE, FOR LANDSCAPE INSTALLATIONS, COMPOST AT A RATE OF A MINIMUM OF FOUR CUBIC YARDS FER lt,l!2l1Zl SQUARE FEET OF FER"!EABLE AREA Sl-lALL BE INCORPORATED TO A DEFTl-l OF SIX INCl-lES INTO Tl-lE 501L. SOILS WITl-l GREATER Tl-lAN 6% ORGANIC MATTER IN Tl-lE TOF 6 INCl-lES OF 501L ARE EXEMPT FROM ADDING COMPOST AND TILLING. PRIOR TO PLANTING! OF ANY MATERIALS, COMPACTED SOILS Sl-lALL BE TRANSFORMED TO A FRIABLE CONDITION. Tl-lE AFFLICATION OF ORGANIC MULCl-l MATERIALS MADE FROM RECYCLED OR FOST-CON5UMER MATERIALS Sl-lALL TAKE PRECEDENCE OVER INORGANIC MATERIALS UNLESS RECYCLED OR FOST -CONSUMER ORGANIC PRODUCTS ARE NOT LOCALLY AVAILABLE. A MINIMUM OF 3' OF ORGANIC MULCl-l Sl-lALL BE ADDED IN NON-TURF FLANTING AREAS. ALL EXISTING PLANTING! DESIGNATED TO REMAIN ON SITE Sl-lALL BE PROTECTED IN FLACE. ANY EXISTING FLANTING DAMAGED DURING Tl-lE COURSE OF Tl-lE PROJECT 51-!ALL BE REPLACED IN KIND TO Tl-lE SATISFACTION OF Tl-lE CITY AND FER LANDSCAPE MANUAL REQUIREMENTS. ~ NO EXISTING! TREES ARE TO BE REMOVED AND Sl-lALL BE \ PROTECTED FROM DAMAGE DURING CONSTRUCTION. TYPICAL - APPROVED FOR IRRIG.A !ION AND PLANTING ONLY, INC:LlJDING l)RECISE LOCA IIC)N OF PLANTING AREA. 11 AS RC[ __ _ EXP ___ _ DATE REVIE\.JFD BY, INSPECTOR DATE 7/08/26 ~====+====[=============================r====[===J=====c===J-;:l====:::;l1:=:==============~ ~11~~11~~ 1---+--+-------------1---1---+---1----1 ~ CITY OF CARLSBAD 1 --:::;~==:;::::----11-I _-_-_-_--ti_-_-_-_--+t _-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_--~-_-_-_-_-_--~-_-_-_-_-_--~t _-_-_-_-+t -~-_-_-+f _-_-_-_--I-+_-_-_-_J ::==:::::=:::'..:::::::====::::PLA"'::::N::::N:::IN::G::::D::::IV:=l:=Sl::O::::N======; LANDSCAPE IMPROVEMENT PLANS FOR: POINSETTIA PROPERTIES (WATERS £ND) PLANTING SHEET l---+--+------------1----1--+----I---I I APPROVED/. /J !!A /J ,,,/,.,_.,,. \ --~~~""-{-"'-<--,J///~AA/l/Vf=,,-__ 11 tD(.PAT'i:tJLE PLANNJNG I' . DATE lNtTIAL ENGINEER OF WORK Expi~ation Date:10/31/26 REVISION DESCRll'TION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL OWN BY: ~EE~_ CHKD BY: ~JT __ RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWJNG NO. 396-7T DI &161-lT Pl&TANCE LINE TYPICAL DIAL TOLL FREE 1 -800-422 -4133 AT LEAST TWO DAYS BEFORE YOU D1G UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA \ -\ 212 ) ,-. ~~ ~c~01 5 --/ ~"t'i"'::..,,~~.~,'"I, / ? 1 (~ \ ~-~' ' _____ ,-• '". ---····\ \ . '· -. ,,.. 58.6 \ \ _____ } \ .'.I \ ' \ . ~- ,.-----. ,,,_ - ,,,,,.-r1 ,_...l .~ -"- ( /L',.....-, I '.. L -·v / -~ __ _,./ \ DESIGNED BY: ~EE~_ DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 - ' ' 196 (~~ \_/0 l .... _., \ ' 2237 FARADAY AVENUE SUITE 120 CARLSBAD,CA 92008 (760} 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE - PLANTING LEGEND WCOU CONTAINER/ lt)ETAIL ""°ACINC, I I I l l l l vvvvv lvvvvv vvvvv ivvvvv " )', ><,; ,C X / / / / / .///// ///// ///// ffi @ ffi @ IB IB IB IB 1£5A:RALOI: P/>RI. 'llR,!l(EUll!TS' (eRIV<Elt;l!TS ~ lOCCAJ Ul1ll La-lANDRA 'ARCTIC fROST' / ARCTIC MAT !i:!J51.l) AND LANT ANA HON. 'R.IRFLE' /TRAILll'l5 LANT ANA F'URf'LE) EALOBILM CANll'1 /CALn=oi.NIA FUQj5fA) WITH SAL VIA LEUCANTHA 'SANT A 6Al<6ARA' /SB. 5AllE) AND ROSMARllffi 'F'l<OSTRATUe' f~EPll'I:; ~Alsl') "105H~INU5 'F'l<OSTRATUe'/C~EPING, ~Alsl') WI Cl5TUS '51.NSET' /MAGENTA ~J LANT.INA MON. 'AfflE' <TRAILi~ LANT.INA RJRFLEJWI Fll¼~IOLEPIS INDICA 'PINKIE' /PIN<IE INDIAN H SALVIA '6EE5 61.155' /BEE'S 61.155 5Ac.E/WI SALVIA LEUCANTHA 'SANTA 6AR6ARA' /SB. 5AllEJ LANTANA MON. 'FlmE' /mAL~ LANT .!NA RJRFLEJ WI LOMANDRA 'ARCTIC FROST' (ARCTIC MAT RIJ&l.l) PLANTING KEYNOTE& LOW 5 C.AL. x 4' oc. 6129 LOW 5 C.AL. x 4' O.C. LOW IC.AL. x !>' O.C. LOW 5 C.AL. x 4' O.C. 6 /29 LOW !, C.AL. x 4' O.C. LOW I GAL. x h' O.C. LOW IC.AL X 6' O.C. 6129 LOW E, ,:;AL. X 48' O.C LOW I C.AL. X 5' O.C. 6 / 29 LOW E> c.AL. X 3&' O.C LOW I C.AL. X 5' OC.. 6 / 29 LOW 5 C.AL. X 4' O.C. LOW I c.AL. X 5' OC.. 6 /29 LOW 5 c.AL. X 4' OC.. r,:;-:;-, EXl5Tlt,i:; TUI-if A~A5 IN PAl<KUIAY TO 6E l<EMOVED AND PLANTED WITH ffiOPOSED PLANTINc.. ~ TYPICAL Irv,! PLANTINc. ALOi'i:; PAl<KWAY 51-lALL 6E MANTAINED AT A MAX OF 311) NCI-IES IN I-IEl(;I-IT fOFs Sl(;I-IT l::'.=I DISTANCE. WHICH INCLUDE BOULDERS. TYPICAL r,:;-=,i ANY T~ES LOCATED WITHIN A YEHICULAR Sic.HT LINE HU5T HAYE ALL LIM65 ~MOYED TO A i:::'.:::'.I HEl(;I-IT OF 6 FEET A60YE THE ADJACEr-lT TOP OF CURB. TrFICAL NOTE: FOR LANDSCAPE INSTALLATIONS, COMPOST AT A RATE OF A MINIMUM OF FOUR CUBIC YARDS PER 1,000 SQUARE FEET OF PERMEABLE AREA Sl-lALL BE INCORPORATED TO A DEPTl-l OF SIX INCl-lES INTO Tl-lE SOIL. SOILS WITl-l t:;iREATER Tl-lAN 6% ORt:;iANIC MATTER IN Tl-lE TOP b INCl-lES OF SOIL ARE EXEMPT FROM ADDING COMPOST AND TILLING. PRIOR TO PLANTING OF ANY MATERIALS, COMPACTED SOILS Sl-lALL BE TRANSFORMED TO A FRIABLE CONDITION. THE APPLICATION OF ORt:;iANIC MULCl-l MATERIALS MADE FROM RECYCLED OR POST-CONSUMER MATERIALS Sl-lALL TAKE PRECEDENCE OVER INORt:;iANIC MATERIALS UNLESS RECYCLED OR POST-CONSUMER ORt:;iANIC PRODUCTS ARE NOT LOCALLY AVAILABLE. A MINIMUM OF 3' OF ORt:;iANIC MULCl-l Sl-lALL BE ADDED IN NON-TURF PLANTING AREAS. ALL EXISTING PLANTING DESIGNATED TO REMAIN ON SITE 51-lALL BE PROTECTED IN PLACE. ANY EXISTING PLANTING DAMAGED DURING THE COURSE OF Tl-lE PROJECT SHALL BE REPLACED IN KIND TO THE SATISFACTION OF Tl-lE CITY AND FER LANDSCAPE MANUAL REQUIREMENTS . NO EXISTING TREES ARE TO BE REMOVED AND SHALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION. TYPICAL APPRO\/t:_D F(JR I RRI G/i_TI ON AND Pl ANTING ONLY, INCLUDING PRECISE LOCATION 0~ PLANTING AREA. 11A TCH llllllCAlES -//,°is AREA SHOIIIN ON THIS SHEET 1Wb r, RCE __ _ REVIE\.JED BY, L.::o-9 iNSPE.C I L:R lXf'. ___ _ DATE DAil 7/os/26 r---r--r--------------T-,--r-,-7r:=====-;-;--_================::::::::::::::;:::::;;;==:;;:::::==:::::;-1 6/16/26 I SH2E4ET 11 CITY OF CARLSBAD 5/05/26 1----+--+----------------+---+--+----+----1 _ PLANNING DIVISION ,--~:::=:::::;:::----i-1-_-_-_-_--+t_-_-_-_-+t _-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_--ti_-_-_-_-+t _-_-_-_-+-I_-_-_-_-+t _-_-_--ti ~LA=N==D=s=c=-A-'=PE===rM==P==R==o=VE==M==E:::::K:::'T=P==L=A==N::;:s==F==o:::;R=, =====::::;I POINSETTIA PROPERTIES {WATERS £NO) PLA"ITiNG SHEET I (1PPROVED /. /J. J. I 1----+---+-----------------1--1---+----+---1 ____ v_U::AA,t,~.c..,c_,/jlp,,.__d1,l,,..,..,.~6-'/:~_~ --it Llff z..v l----+--+----------------+---+--+----+----1 :::::P:::::LA:::::NN=:IN:::::G=;;;;::::=::;--;:=="======;;::_=-=-=D-=AT.=E==~- DATE INITIAL ENGINEER OF WORK Expiration Date:10/.31/26 Rt VISION DESCRIPTION DATE INmAL DATE INITIAL OTHER APPROVAL CITY APPROVAL DWN BY: ~E~E -- CHKD BY: =JT __ RYWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-?T \~/ \ ....... \ \ ' ,\ \ \ \ \ \ ,---. \ \,.... \ \\· DI '-~, _ RT DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA \ &IGI-IT DISTANCE LINE TYPICAL 147 J nl------ --· • --- ' \ '\ <IE) ~- ( 5(1~) EXl&Tn-trs LANDSCAFE TO i;£MAIN TYPICAL ~ ? EXl&Tn-trs &mEET ~&TOi;£MAIN TYPICAL R .... _ ~~=-:±~---- .... ' ' ,, , / \ ( ·-r -, rm ... ~,., .--\ i \, K,f,-,t-, • 56. l ' -------·1 ~-q .) ; \..../ ,_, --- PLANTING: LEGEND YM60L DESCRIPTION RI DETAI 85 1E5FERA1.a, PARI'. !lRAl(Elk'.illTS' (llRA'(]:Lr.HJ5 ~ YOCCA! 111TH LOW S GAL. x 4' O.C. B / 29 LOMANDRA 'ARCTIC FROST' (ARCTIC MAT RUSI-I) AND LOW S C:IAL x 4' O.C. CT> LANTANA MON. 'RJRFLE' <TRAILING. LANTANA FURFLEJ LOW I GAL. x S' O.C. vvvvv 85 EPIL0611.M CANil'1 (CALIFOl<NIA ~A! lll!TH LOW S C:IAL. x 4' o.c. B /29 vvvv &AL VIA LEUCANTHA 'SANTA 6A1'!6ARA' (5.6. 5AGEJ AND LOW S C:IAL. x 4' o.c. vvvvv vvvv CT> ROSMARINU5 'F!WSTRAiUS' <CREEPING. ROSEMARY! LOW I GAL. X Ii,' o.c. ffi ROSMARINUS 'PROSTRAiUS'/CREEPINGi R05EMARYJ WI LOW I GAL X Ii>' O.C. Bi 29 Cl511JS '5UN5ET' /MAGENTA ROCKRO!iE) LOW S C:IAL. X 48" OC ///// ffi ///// LANTANA MON. l'URPI.E' (TRAILl!lkl LANTANA f\JfsFLEJ WI LOW I GAL. X S' O.C. BI 29 / / / / / RHAFHIOLEPl5 WICA 'Plll<IE' /Plll<IE INDIAN l-!Al!IT~ LOW S C:IAL. X 36' O.C ///// ffi &ALVIA 'BEES 6LI55' <BEE'S BLl55 SAGE! WI LOW I C:IAL. X S' O.C. BI 2~ SAi.ViA LEUCANTHA 'SANTA 6A1'!6ARA' (5.6. SAGE) LOW S GAL. X 4' OC. 0)21 LANTANA MON. 'FIJRFLE' <TRAILl!lkl LANTANA AJRPLE)W/ LOW I GAL.XS' O.C. B 12~ " • • • " @ LOMANDRA 'ARCTIC FROST' (ARCTIC MAT RU51-1) LOW 5 &AL. X 4' 0£. PLANTING: KEYNOTES r;:;:;, EXl&TINC. Tiff AREAS N PA!sKLUAY TO BE REMOVS) AND PLANTED WITI-I PROPO&ED Fl-ANTING. L::..!J TYPICAL Irv,! PLANTING ALONG PAR<l!JAY &I-IALL 6E MAii-IT ANED AT A MAX Cf 3i!l INCi-iE& IN 1-!Elt:,I-IT FOR 5I(:il-!T ~ DISTANCE. WfllCI-I NCLIJDE 60\JLDEJs&. TYPICAL r,:;-:,J ANY TREES LOCATED WITI-IIN A VEI-IICULAR 5IGI-IT LINE MUST I-IAVE ALL LIM65 REMOVED TO A l:'..::::I 1-!Elt:,I-IT Cf Ii> FEET A60VE Tl-IE ADJACENT TOP Cf CUl<f!. TYPICAL REFER TO SHEET LP-11 ADDITIONAL NOTES. ---7----tEXl&Tn-trs LANDSCAFE TO i;£MAIN TYPICAL ' ,... ' -\, '\ ....,......_~ ~, FOR ) i ($ ....-;---, I .. ,, ( 53. ~ I ' \ 4 'CJ ~-L -HATCH INDICATES~ • ;:A= OIi ICIIJ'f PP ..-.... ~ • DESIGNED BY: ~EE~_ DATE: 04/21/2026 DRAWN BY: EE SCALE: I'S INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 /,, ,1,I/. /./.,./// "//// ... / / .. /; . --1//li/ ~- I THE ,-LIGHTFOOT PLANNING GROUP PLANNING 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE APPROVED 1OR IRRIGATION AND Pl_ANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING ARE/\. RCE __ _ EXP. ___ _ DAT[ R[Vl[\i[D BY, INSPECTOR DATE 7/08/26 ~====r====i============================J====r===J====J====.r:::=======~=======================:;i 6/16/26 SIW,T CITY OF CARLSBAD 5/05/26 l----+--t---------------+---+--1-------+---I 25 PLANNING DIVISION r---~=====:;::---tt--=---=--~t.-=---=--t-=---=---=---=---=---=---=---=---=---=---=---=---=---=---=---=---=---=---=--~t-=---=--t-=---=--t-=---=--~t-=--"=i ;::=:::::===-'======================; I LANDSCAPE IMPROVEMENT PLANS FOR: WATERS £NO INTERIOR RETROFIT PLANTING SHEET l---+---+--------------l-----1---+----1---11 APPROVFDC-ieu-t J.tutr/ l----+--t---------------+---+--1-------+---1. PLANNING l Tu VI Zl!_ I DATE _ l--::-:DA=rE-+-::1N:::ITc:-:IAL-+---------------+-D-AT-E -+-1N-ITIAL-I---DA-TE-l-1N1-r1A-L-I DWN BY: EE PROJECT NO. I DRAWING NO. 1---~--t---------------+=:..::..::..--'--=--=-f-C--=--____L_=-=---i CHKD BY: ~JT__ CT 00-16 )()()( X Exp;rat;on Dote1O/31/26 ENGINEER OF WORK REVISION r:JFSCRIPTION OTHER APPROVAL CITY APPROVAL L::Rc'.!Wl!!cD..=B"'-Of:---'===-1 ~--------' - \ ,,-· \ I -\ 1 j..":-=-\,,,,.,,--1 DI EXISTING STR!!!ET r---..... TIEE& TO f'<EMAIN TYPICAL RT DIAL TOLL FREE 1-800-422-4133 AT LEAST 1VJO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA ,-.. ( ,___, . I \ \_ """ \ I \ \ : QI_! 7~-,, •. ' I_..,/; r -, I • l • I l__ ,.J ,_,. /. ' \ I \ I \ \ \ (174 :,-:c~\ \ l 57.oJ ' \ ,56 J I 'l '-=' \ .,# ; I ' . ....., __ ' ·, I . ! / ~--~~ I r r DESIGNED BY: _E=E~-DATE: 04/21/2026 DRAWN BY: EE SCALE: PS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 l / ·-. --1---, __J ! !,1 ' / I I ' I ·/ ; / ,/ Y.. i \~---lEXISTING LANDecAFE TO f'<EMAIN TYPICAL ----TKE ==II==--==: .. LIGKTFOOT 2237 FARADAY AVENUE SUITE 120 PIANNING CARLSBAD, CA 92008 GROUP (760) 692-1924 www.lightfootpg.com PLANTING LEGEND YM60L R.,WT DESCRIPTION ETAI ~ ~OE P1'R/. ~5• /~li,IITS l<ED llJCCA)lli™ LOl!J &GALx4' O.C. 6 / 29 LOMANDRA 'ARCTIC FR05T' /ARCTIC MAT FaJSI.IJ AND LOl!J !', GAL x 4' O.C. LANTANA MON. 'FURfl.E' /TRAILING LANTANA FURPLE! LOl!J I GAL. x !',' O.C. vv vvv ~ Ef'IL06111'1 CANll'I /CALIFOl'iNIA l'OC~IA/ WITH LOl!J !', GAL. x 4' O.C. 6/29 vv vv vv vvv SAL VIA LE\ICAl'!THA 'SANTA 6AR!lARA' 15.6. 5.<!6EJ AND LOl!J !', GAL. x 4' O.C. vv vv ROSMARIIIJ& 'FROSTRAl\l&' (CREEPING ROSEMARY! LOl!J I GAL. x 6' O.C. ffi ROSMARINU& 'PROSTRAl\l&'/CREEPING ROSEMARY! WI LOl!J I GAL X 6' O.C. 6 / 29 CloTU5 'euNSET' (11A(;fNTA ROCKROSEJ LOl!J !', GAL. X 4a' O.C // /// ffi // /// LAWl>NA Mal. 'RWLE' (TRAIL/1'6 LAWl>NA FURPLE! WI LOl!J I GAL. X &' O.C. 6 / 29 // /// i<HAPl!IOLEFIS INDICA 1"N<IE' IPINKrE INDll>N l<Alll!HC)Ji!,I LOl!J !', GAL. X 36' O.C // /// (D21 SAL YIA '!lEES 6Llo5' /6EE'5 6Llo5 SAGE! WI Q) SAL VIA LEI.Cl>NTI-IA 'Sl>NTA 6AR!lARA' 15.6. 5AGEJ LOl!J I GAL. X !',' O.C. 6 / 29 LOl!J !', GAL X 4' O.C. (D21 Ll>NTl>NA MON. 'RJRPLE' ITRAIL/1'6 LANTANA FIJRPLE! WI LOl!J I GAL X !',' O.C. 6 / 29 Q) LOMANDRA 'ARCTIC FR05T' /Af<CTIC MAT 1<11514! LOl!J !', GAL. X 4' O.C. PLANTING KEYNOTES r;:;-:;] EXISTING TURF AREAS IN PAi'il<UIAl TO 6E REMOVED AND PLANTED l!JITH PROPOSED PLANTING. ~ TYPICAL r,;-;:;J PLANT!tol::i ALONG PAF<KWAT SHALL 6E MAINTAINED AT A MAX Cf 311') INCHES IN HEIGHT FOR 516H ~ DISTANCE. lll-41CH INCLUDE 60ULDERS. TTPICAL lrvi! AN-r Tli?EES LOCATED WITHIN A VEHICULAR SIGHT LINE MUST HAVE ALL LIM65 REMOVED TO A l':::.::1 HEIGHT Cf fa FEET A60VE THE ADJACENT TOP Cf CUR6. TYPICAL NOTE, F~ LAND5CAFE INSTALLATIONS, COMPOST AT A RATE OF A MINIMUM OF FOUR CUBIC YARDS FER 1,e>@@ SQUARE FEET OF PERMEABLE AREA SI-IALL BE INCORPORATED TO A DEFTI-I OF SIX INCI-IES INTO Tl-IE SOIL. SOILS WITI-I GREATER TI-IAN lb% ORGANIC MATTER IN Tl-IE TOF lb INCI-IES OF SOIL ARE EXEMPT FROM ADDING COMPOST AND TILLING. PRIOR TO PLANTING OF ANY MATERIALS, COMPACTED SOILS SI-IALL BE TRANSFORMED TO A FRIABLE CONDITION. Tl-IE APPLICATION OF ORGANIC MULCI-I MATERIALS MADE FROM RECYCLED OR POST-CONSUMER MATERIALS SI-IALL TAKE PRECEDENCE OVER INORGANIC MATERIALS UNLESS RECYCLED OR POST -CONSUMER ORGANIC PRODUCTS ARE NOT LOCALLY AVAILABLE. A MINIMUM OF 3' OF ORGANIC MULCI-I SI-IALL BE ADDED IN NON-TURF PLANTING AREAS. ALL EXISTING PLANTING DESIGNATED TO REMAIN ON SITE SI-IALL BE PROTECTED IN PLACE. ANY EXISTING PLANTING DAMAGED DURING Tl-IE COURSE OF Tl-IE PROJECT SI-IALL BE REPLACED IN KIND TO Tl-IE SATISFACTION OF Tl-IE CITY AND FER LANDSCAPE MANUAL REQUIREMENTS. NO EXISTING TREES ARE TO BE REMOVED AND SI-IALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION. TYPICAL i\PPRC)VED FOR I RRI c;A Tl ON 1\ND PLANTING ONLY, I NC:LLJDI NG PRECI SC:: LOCATION 0~ PLANTING ARFA. RCE __ _ EXP. ___ _ DATE REVEwED BY: ~====~====l============PLA=N=Nl=NG====Sl=TE=□E=Sl=GN===LAN==□=SC=AP=ErAR=CH=IT=ECT=UrRE====r====1====-.rrL=P=-==1==1::!-;=1 N=S=P=Ec=·=10=R============D=A=T=l =~ 7/08/26 6/16/26 t---t----+------------1---1---1-------1-----I fsHml I CITY OF C ARLSBi\D 5/05/26 ~ . PLANNING DIVISION ,--~:::===:;;::::----lt====j====1===============================±====t====t====i===j ~L=AN:::D::::S::::C=,A,':PE:::::::::I=M:::PR:::O::::V::::E=M:::E::::NT==::P=:L=AN:::S:::=;F':::O:::R::::: =====~I POINSETTIA PROPERTIES (WATERS £ND} PLANTING SHEET IAPP __ ROVED /',/J _ _ 7 l----+--1-----------------1----L----1---l..--_j -__ ...,,Y=....L-'~"" ~ fq),~ l----+--+------------------1----l----.l.----L--.J PLANNING / ' l--=c--t~~+------------------1----l----+-----L--.J OWN BY, -'cEE.,___ DATE INITIAL DATE INITIAL □ATE INITIAL 1----'---+----------------+..=C::.::.......L.::.::.:..::.:::.....,_.:::..::.:.~..::.:.:.:::.:::...__J CHKD BY: JT __ Expication Dote:10/3_1/26 ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: PROJECT NO. LPC2026-0014, CT000016 ---i ( ({_p(Zk I DATE DRAWING NO. 396-?T _, EXISTING LANDSCAPE TO REMAIN TYPICAL ~· \ \ ... t. I · • \1\ I ,-\ ~\ \ , \·\,:__\,('\ \_ ...... \ \ ' \~\ ~\ \ \-=-\\ ~ \ \\\ 1 \ \ _, . '~ \ -· \ \\l. \ \\\ \ ~ ~·•"" \ ....... \ ~ /1. \ ..,..\ \ \,\ \ NOTE, \ \ • \\\.-7 \ '\ :'...:;.'\' \ \ -\ 't FOR LANDSCAPE INSTALLATIONS, COMPOST AT A RATE OF A \.,, \ MINIMUM OF FOUR CUBIC 'I' ARDS PER 1,0@@ SQUARE FEET OF \~\ ' PERMEABLE AREA 51-lALL BE INCORPORATED TO A DEPTl-l OF 5~:>!,'·_\ '\\ \ INCI-IE5 INTO Tl-IE SOIL 5O1L5 WITl-l GREATER TI-IAN b% ORGANIC \..,..&"1 \ ~~ \ MATTER IN Tl-IE TOP b INCI-IE5 OF SOIL ARE EXEMPT FROM ADDING'.•\ ~1 ~ , COMPOST AND TILLING. \-::..\\ 1:. \ PRIOR TO PLANTING OF ANY MATERIALS, COMPACTED 5O1L5 51-lALL \;t. \ \~ \ BE TRANSFORMED TO A FRIABLE CONDITION. \-... \ \ ),.t7\ \ \ ¥'.-' ' \ Tl-IE APPLICATION OF ORGANIC MULCl-l MATERIALS MADE FROM RECYCLED OR POST-CONSUMER MATERIALS 51-lALL TAKE PRECEDENCE OVER INORGANIC MATERIALS UNLE55 RECYCLED OR POST-CONSUMER ORGANIC PRODUCTS ARE NOT LOCALLY AVAILABLE. A MINIMUM OF 3' OF ORGANIC MULCl-l 51-lALL BE ADDED IN NON-TURF PLANTING AREAS. ALL EXISTING PLANTING DESIGNATED TO REMAIN ON SITE 51-lALL BE PROTECTED IN PLACE. AN'!' EXISTING PLANTING DAMAGED DURING Tl-IE COURSE OF Tl-IE PROJECT 51-lALL BE REPLACED IN KIND TO Tl-IE SATISFACTION OF Tl-IE CIT'!' AND PER LANDSCAPE MANUAL REQUIREMENTS. NO EXISTING TREES ARE TO BE REMOVED AND SHALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION. T'r'PICAL \/\\ ~ \ . \ \ .....-\ ~ ~ \'\\ •• \ \-...... \ \t. \ '-~-~~ '· \ '' \ .,, • .. \ ,\ DI RT DIAL TOLL FREE 1-800-422-4133 AT LEAST TWO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA 181 J ~-----/' , DESIGNED BY: -""EE~_ DATE: 04/21/2026 DRAWN BY: EE SCALE: AS INDICATED PROJECT MGR.· J. TAYLOR JOB NO.: 1765.01.1 5 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE PLANTING LEGEND YM60L DESCRIFTICN CONTAINER/ ETA! ACIN6 ffi IIE5FERALOE PIIN. '6RA'(ELr.H15' ~IG!ITS FiED 11.IXA) 11111 LOW !', GAL. x 4' OC. El/ 29 La-1,IJ,IDRA 'ARCTIC FROST' (ARCTIC MAT l<ll$-I) ,IJ,ID LOW !', GAL. x 4' OC. @ LANTANA M<:1'-1. 'FIJl<f'LE' (TRAILING LANTANA FUl<f'LEJ LOili I GAL. x !',' OC. vv vvv ffi EFIL061UM CAIU1 (CAL~IA i'I.ICI-ISIA) Wlrn LOW f, GIAL. x 4' OC. El/ 29 vv vv SALVIA LEOCANIHA 'SANTA BARBARA' /55. SAGE! AND LOW !', GAL. x 4' OC. vv vvv vv vv @ ROSMARINUS 'PROSTRATUS' /CREEPING RCSEMARYJ LOW I GAL. x 6' O.C. ffi ROSMARIHLI& l'RCSTRATUS'ICREEPING RCSEMARYJ WI LOili I GAL. X 6' OC. 6/2':I CISTUS '51JNSET' /MAGENTA ROCKRCSEJ LOili 5 GAL. X 48' OC ~··· // /// ffi LANTANA l'ION. 'FUl<FLE' /TRAILING LANTANA FIJRFLEJ WI // /// LOW I GAL X f,' O.C. El/ 2':I // /// RHAPHIOLEPIS n-lDICA 'PINKIE' /Fir-!<!£ INPIAN M LOW 5 GAL X 36' OC // /// ffi SAL VIA 'BEES !3LIS5' /!3EE'S !3LIS5 SAGEJ WI LOW I GAL. X 5' OC. El /29 SALVIA LEUCANTMA 'SANTA 6AR!3ARA' /55. SA(;f) LOW 5 GAL. X 4' OC. PLANTING KEYNOTES. r;:;:;J EXISTING TUl':f AREAS IN FAl<KlllAY TO ElE REMOVED AND PLANTED WITH PROPOSED PLANTING,. l::'...:.I TYPICAL r;:;-;:;J Fl.ANTING ALc;,i,«; PA!iKWAY ~ALL ElE MAINTAINED AT A MAX OF 3~ INCHES IN HEIGHT FOR 51GtHT ~ DISTANCE. ~IOI INCLUDE BOULDERS. TYPICAL .,_, ANY 11-!EES LOCATED WITHIN A VEHICULAR Sl~T LINE MUST HAVE ALL LIMl35 REMOVED TO A llEI~ OF 6 FEET ABOVE THE ADJACENT TOP OF CURB. TYPICAL ' ---1: _.l. • -• ,,_ .... \ 11 AS RCE __ _ EXP, ___ _ DATE REVl[VED BY, lNSP[CTDR DATE 1/os/26 r-7--r--------------r-,-,r-T-,r~=-=-=-::....,:::;';:=========:::::::========::;1 6/16/26 SHEET CITY OF CARLSBAI) 5/05/26 1----+--+----------------+---t-----<>----+----1 2 I PLANNING DIVISION ,---:::::;;:::=~;::::---1-r-_-_-_-_-+t _-_-_-_--1-t _-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_--=-=-:-_-_-_-_-_-_-_--+1--_-_----1-t _-_-_---"j_=-=--_-_-j-1_-:-_=-=-.1 ~L=AN=D=s=c=-AP'=E=IM=P=R=o=v=EM=E=,N==T=P==L=A=N=s =F==o==R=: =====:::;I POINSETTIA PROPERTIES {WATERS END) PLANTING SHEET ,___.,__--+------------+--+----<~--<---I I APPROVED~ d~ ~ 1 (r<J{zv\ . PLANNING ~T DATE . DATE INITIAL ENGINEER OF WORK Exp:ration Date:10/31/26 REVISION DESCRIPTION DATE INITIAL OTHER APPROVAL DATE INITIAL CITY APPROVAL OWN BY: EE CHKD BY: =JT __ RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T ~-PVC EXI-IAU5T I-IEADER AIR RELIEF VAL --POLY DRIFLINE TEE FITTING (TYF.J --PVC 5UPFL Y HEADER MANUAL FLUSH 28. VALVE PVC EXHAUST _ __, HEADER ® TEARDROP/ UNDIJLA TEIN6 DRIP LAYOUT SCAif: NTS ~---10" ROUND VALVE BOX - BRANDED 'FV' ----3/4" MIFT X MIPT THREADED KBI &ERIES BALL VAL VE OR APPR EQUAL T X B MALE ADAPTER -~ LINE SIZE HUNTER 3/4" PLD -Mlil.Wi'tt:~;:==::==:ij~t==~U.!_'.l"'..,:TYI::0'.P~ 075 OR EQUAL Ii FINISH GRADE • _j HUNTER PLD BLANK ~ () 3/4" PVC LINE FROM EXHAUST HEADER - 11MM TUBING OR EQUAL ---REFER TO 5PECIFICATION5 42" LONG COIL ir:~r-~==!__-BRICK SUPPORT FULL PERIMETER ,.._::: _______ l CUBIC FT 3/4" MINUS 'o !fd;i?8 CRUSI-IED ROCK 0 @~M_A..;_NU.;..;.AL-=-F;_;;UJ;;;.;;..;;;..;SH~V;_AL;;;._YE.;...;;;__ __________ SC_AI-F:-NTS-- FEED END LAYO UT le I I I I I I I I I E 0 REMOTE CONTROL VAL VE WITH DISC FILTER AND PRV ED CENTER FE LAYOUT lfi .J. ~ :iii .._ ~ ~ f I/ I -' = ~ "' I PVC OR POLY 5UFFL Y HEADER DRIP &TART CONNECTION MALE ADAPTER DRIFLINE TUBING LATERAL AIR/VACUMN RELIEF VALVE -(PLUMBED TO TECHLINE AT EACH HIGH POINT) AREA PERIMETER PERIMETER LATERALS 2' T0 4" FROM EDGE BLANK DRIPLINE TUBING ( CENTERED ON MOUND OR BERM PVC OR FOL Y EXHAUST I-IEADER POPUF DRIP INDICATOR FOR 5Y5TEM ~ OPERATION. &EE DETAIL DI 28 ~1[21-----PLUMBED TO PVC OR POLY LINE FLUSHING 't'..I VALVE DRIFLINE "END FEED' LAYOUT I I I I I I I I I 1M -1L ~ ~ I'-" 1"'- I I ,r I/ • / 1 V I/ •• ::□) I J I I/ I ' I ' -k-- g)---------------~ \__ LF @ DRIPLINE T'rPICAL LAYOUT H f----~------SCALF: N. T.5. I 3" MULCI-I _l LAYER ICATOR FOR SYSTEM OPERATION. 5E fffiftl-lr§,li<!.fl_Df 3" ·-----L BLANK TUBING (PER DETAIL5J I . GAL V. TIE DOWN 5T AKE, RAIN BIRD TDS-060 i i i' ', 1, ~----DRIPLINE OR ~--' .,_, ~"-'--11 __ JU--'~.....,_--~ BLANK TUBING 10' O.C. SLOPE, 20' O.C. FLAT, EACI-I CI-IANGE IN DIRECTION BARB FEMALE TEE ADAPTER 11mm X 3/4' FFT PVC NIPPLE '□ ~--BARB MALE ADAPTER 11mm X 3/4' MPT NET AFIM ADAPTER ~===:=:::--PVC TEE 5xSxT ~ ,r PVC TEE 5xSxT ="'I/ OR STREET EL "---------L------'---~--FVC SUPPLY I-IEADER PVC TO DRIPLINE OR XF BLANK 1\JBING CONNECTION r--PVC LATERAL "---------L------'----"' SIZED FER FLOW/PIPE SIZE CI-IART PVC RISER TO 1\BNG @ TYPICAL FITTIN6S FOR DRIPLINE TO HEADERS AND= ~~N6S D .. ' -11 I-- =1 I 1=1 11::::':,ll---u........rµ'-I I I==--I I --1 Tf 111 I 111-:--FINISHED GRADE PLANTING AREA 11 111 111=1 11- ,1,l..,1_..l,...l;,-----HUNTER ECO-ID SYSTEM OPERATION INDICATOR ~-&Cl-I 405TREET ELL 5CI-I. 40 PVC. STREET ELL &Cl-I 80 PVC NIPPLE -LENG Tl-I AS REQUIRED (8' MIN.J ~--SCI-I. 40 PVC TEE SST ~-&cl-I 40 STREET ELL ~ J~d~-----PVC LATERAL LINE. INSTALL I-IEAD ON LATERAL .._ JU5T DOWNSTREAM FROM VALVE, TO INDICATE OPERATION OF DRIP 5Y5TEM IRRIGATION 6 11 POP UP DRIP SYSTEM OPERATION INDICATOR SCALE: N.T.5. FINI~ GRADE 6' ROUND VAL VE BOX AIR/ VACUUM l]~~ RELIEF VALVE ~o 1/2" PVC COUPLING (TxT) 00 C3 FILTER FABRIC 0 Q O 0 Q 0 1/2' 5CH 80 RISER oo oC3 0 0 tLENGTI-I A& REQUIREDJ 0 BRICK SUPPORTS (TI-IREEJ 3/4' CRU51-1ED GRAVEL 5UMF Q_ ____ L _ _J. ___ _o,---pvc PIPING AND FITTINGS ® AIR/V ACUIJM RELIEF VAL YE E------'----~----sc•• e: N.T .s. LINE FLUSHING VALVE PLUMBED TO PVC OR FOL Y ISLAND LAYOUT DRIFLINE 5T ART CONNECTION MALE ADAPTER PVC OR POL 'f EXI-IAU5T I-IEADER PVC OR FOL Y SUPPLY HEADER DRIFLINE 5T ART CONNECTION 5EE DETAIL 4 OF 4 REMOTE CONTROL VAL VE WITI-I DISC FILTER AND FRV BLANK DRIPLINE TUBING (CENTERED ON MOUND OR BERM) AREA PERIMETER AIR/VACUUM RELIEF VALVE DRIFLINE TUBING LATERAL PERIMETER LATERALS 2' TO 4' FROM EDGE FOPUF DRIP INDICATOR FOR 5Y5TEM OPERATION. CENTER FEED HEADER ! !I I " ' i! i w',; -9F~iiil=iiiii:::1::i:=l□-REMOTE CONTROL VAL VE 11 WITI-I DISC FILTER AND PRV I IU...U----DRIFLINE TUBING lh rr;,,-~,;,=;==~1----PVC TEE I I 5UFPL Y I-IEADER lh""'=-=="=dl~----ISLAND PERIMETER _..,---FOFUF DRIP INDICATOR FOR SYSTEM OPERATION. :;;£{;,ft~==== PVC ELL r,;::;..; ~--AIR/VACUUM RELIEF VAL VE 11 <PLUMBED TO DRIPLINE AT EACH I-IIGI-I POINT) I LINE FLU51-11NG VALVE lb PLUMBED TO DRIFLINE DRIP LINE BARB MALE ADAPTER IMPORT ANT NOTE&, PRE55URE LINES (LANDSCAPE) L DEFTI-I OF COVER ~ALL CONFORM TO CITY 5T ANDARD5 LE55 TI-IAN 3" DIA. -18" COVER 2. FIFING AND CONDUIT 51-!ALL BE SLEEVED UNDER ALL I-IARD5CAPE 5LEEVE5 &HALL BE 2X FIFE/CONDUIT DIA. 3-5-1/2" DIA. -24" COVER b" OR GREATER -3b" COVER 3. NO OTHER TRADE WORK ~ALL BE ALLOWED IN TRENCH LATERAL& (LANDSCAPE) 12" COVER w w -\I) -N \I) - w li'-'k----'lrl ~ 11-011 MYLAR TYPE DETECTOR TAPE ENTIRE LENGTI-I OF MAIN FINl51-1 GRADE DRIFLINE LATERALS / ~8tFACTED PER FLAN FINISI-I GRADE FINl&I-I COMPACTED ,4" MIN.. GRADE -'k---~--,.......,.,,..,_--.-'-i'----5_0IL 'i l COMPACTED &OIL -N ' . i-•-itAi~IEf:,·•.•··. :,.~--./.•.,:··.·:{ .... ~_:.:· ,_-...:.:~-:,,·/·): '·/ ," ,_ .. ·-:··· --.: .. ··.··~· -•. , .. : .. ·---,. ~· .. __ .-. ,, -· r' ,:--,......__CONTROL CONDUIT : -· ·: -. • • • -• --' OR DB WIRES -< :_< :.; .-·;;-": .' TIE/TAPE WIRE • ·._., . •. ·-.. ·- BUNDLE TO PIPE t," t," MIN. LATERAL LINE& &AND MAINLINE 20' O.C. OR Cl-ING. MAIN AND CONDUCTORS IN DIRECTION LATERALS .J.-lL}:::!2::;_z::1-._~coNTROL CONDUIT CONDUCTORS ONLY ® TRENCHIN6 DETAIL SC&I F: NO SC.Alf CONG. SIDEWALK NATIVE 5UBGRADE PLANTING PER PLAN PREPARED 50IL BED FOR DRIP IRRIGATED TURF/ PLANTING REFER TO 5FECIFIACTION5 IN-LINE DRIP TUBING <TYP.J ON GRADE-COVERED BY 3' BARK DEPTI-I 12' MAX. OC. LINE &PACING CURBl GUTTER (TYF.J "' ... 'f <J LI ® n'PIGAL DRIPLINE BURIAL B f--------'------- SCA! F: 1-1/2"=1'-0" -~--------------PVC SCI-I 40 ELL AND 5Cl-l 80 NIPPLE ~------------PVC 5Cl-l Bel NIPPLE AND TRUE UNION ~----------30-INCI-I LINEAR LENGTl-l OF WIRE, COILED ----------WATER PROOF CONNECTION (I OF 2J ---------ID TAG FOR VALVE, STA.I POC 2-~==cir,"\i""~~,.-,---~;l---'----TOP OF MULCI-I OR TURF . I :I I r---- ·1u f ];:;;;:~ , = I FINl51-1 GRADE I JUMBO VALVE BOX W/ COVER-BRAND WI STA. No. FVC &Cl-I Bel UNION I ..,........,___ PVC 5Cl-l 40 MALE ADAPTER c;;,, '--kl'.hlk-'-i---+~ F OW .J ' 11~0" PVC LATERAL PER PLAN& "'o\Soo ~~t-,, 0 ,,8 a GEOTEXTILE FABRIC n,p..111-,+.e~-1--t-3/4" MINUS CRU51-1ED ROCK -8' DEPTI-I T"jT-1 , _ _f_L:_~~~~§:::~~fnH::1--:=!..!.' 1:...· -CONTROL A5&EMBL'r -BALL VALVE, RCV 4 FILTER I-REFER TO PLANS =~~~~<==============-PVC MAINLINE PER PLAN& PVC 5Cl-l 40 TEE OR ELL ~--------------PVC 5Cl-l W NIPPLE /2-1~ LENG Tl-I, I-IIDDEN) AND PVC 501 40 ELL C, DRIP VALVE ASSEMeLY-(RC,V RE6ULATOR, FILIER) SCA! e l"=l'-0" "AS BUILT" FER LEGEND 11mm X 3/4' MFT 3/4" PVC TEE (TXTX5) ..--RIGID PVC RISER ,___...., ...--pvc TEE (5XSX5) v,;.--,;,-J OR PVC ELL/5XSJ ------PVC CENTERFEED I-IEADER SIZED FER FLOW& I THE ...., I.IGHTFOOT PIANNING GROUP PLANNING 2237 FARADAY AVENUE SUITE 120 CARLSBAD, CA 92008 (7601692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARCHITECTURE APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PI_ANTINC; ARlA. DI RT DIAL TOLL FREE 1-800-422-4133 AT LEAST 1WO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA REVIE'w'ED BY, INSPECTOR DAT[ DATE END FEED SUPPLY OR EXHAUST HEADER " I I U I I DTL-1 7/08/26 i-1-===J~===r===================~=======[===r===J====r===j-';::::::=:::::::-::::::==========================::1 6/16/26 ISH2E8ETII CITY OF CARLSBAD " I I i, I j DRIFLINE PER LEGEND EIARB MALE ADAPTER 11mm X 3/4' MPT 3/4" PVC ELL (5XT) ---RIGID PVC RISER ,___ ..... ...--PVC TEE (5X5X5J OR ELL<5X5J ~--PVC END FEED I-IEAD SIZED FER FLOWS DESIGNED BY: _,Ea'=-.E --DATE: 04/21/2026 DRAWN BY: --'E"""E ___ SCALE: AS INDICATED PROJECT MGR.: J. TAYLOR JOB NO.: 1765.01.1 5/05/26 1----1----l----------------l-----l-----1-----1------1 _ PLANNING DIVlSION r--::?=::::;:::---71--_-_--1-~ _----+t_-_-_-_-_-_-_-:_-_-_-_-_-_-_-_-_-_-_-_-_-:_-_--+t_-_-_-+-t-_-_---li_-_-_---tt_-_----17 ==='----'====:::::::::'::::::':::::::===::::'::=::::=====~ LANDSCAPE IMPROVEMENT PLANS FOR: POINSETTIA PROPERTIES (WATERS END) LANDSCAPl DETAILS 1-----l----1--------------4---l----l---1-----IIAPPROVlU~ R;;,Ut.u;/' l----1----l----------------1-----1-----1---4-----I . PlANNING p l----l---+---------------1-----1-----1---4-----I DWN BY: ~EE~_ 1-D_AT_E ~I_NIT_IA_L +---------------1--DA_TE__i__lN_ITIA_L-+-_DA_JE__i__lN_ITIAL---I CHKD BY: _,_,__JT __ Expiration Ootel0/31/26 ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CllY APPROVAL RWID BY, PROJECT NO. LPC2026-0014, CT000016 1./tV/11.P I DA-it DRAWING NO. 396-?T l TIil .,.,UGHTFOOT PIANNING GROUP PLANNING 2237 FARADAY AVENUE SUITE 120 CARLSBAD,CA 92008 (760) 692-1924 www.lightfootpg.com SITE DESIGN LANDSCAPE ARC'J-\ITECTURE 7/06/26 NOTES: PA!sl<WAY LANDSCAPE TO HAVE ONE IRRJGATION ZONE, [II SIJl;!'ACE DRIP -PAl<KIIJAY IRRIGATION TO 6E CONVER1ED !EXIST/I-I'.:! SFRAY HEAD TO 6E l<EMOVEDJ REl'ER TO NOTES, DETAILS AND MANUFACTURER'S GUIDELINES FOR PROPER LINE SPACING AND LOCATION OF MANUAL FLUSH VALVE AND AIR RELIEF VALVE. :?; STREET DR/FL/NE TYP. LAYOUT DRIVEWAY CTYPJ CURB PAi.KWAY PLANTER STRIP ~ --"l<--1;---==-== =-~=-_= ~= =--.--i-=--_ -=-=_ -_ -=~= =_ =--,~-n-,--- ~ -. - - - --. - - ----- - Q ------3 __ ------• [I] 51 EWALK LENGTH VARIES -ADJUST FER FLAN ~EX-M-AI-NL-IN_E_-+ 'LONG' PAl<:KWAY STRIP _____ _,, FE LAN SLEEVE CR0551N6 LENGTH VARIES 'SHORT' R<llJ'r STRIP RP SEE PLAN FOR LOCATION ® TTPICAL PARK}1AY IRRIGATION -SCHEMATIC A f----___,;,,___ ______ _ SCA! e NO SCALE NOTE, QUANTITIES V<IILL VARY DEPENDING ON LENGTH OF PARKV<IAY PLANTING KEY PLANTINS PER CD PLANTING TYPE 4 SPACING PER PLANTING KEYNOTES REFER TO PLANTING PLAN O LESEND ~ m ,-,T-T777'-~~~--BOULDER TYPICAL@ l~ ~~ <l)w PLANTING TYPE $ SPACING PER PLANTING KEYNOTES REFER TO PLANTING PLAN IL L---t--J NOTE: PLANTING SHALL BE MAINTAINED AT A MAX OF 30" HEIGHT FOR SIGHT VISIBILITY ALONG PARKV<IAY. TYPICAL 'V PLANTING TYPE 4 SPACING PER \.:::V PLANTING KEYNOTES REFER TO PLANTING PLAN ~ 2'-30" DIA. SUNRISE BOULDER -~BY KRC ROCK (BOULDERS SHALL NOT EXCEED 30" HEIGHT FOR SIGHT CLEARANCE TYP. '---BARK MULCH TYPICAL ~-:;;,..c..+----cONCRETE SIDEJl,IALK ® CORNER PARKNAY PLANTING 1YPICAL B ---------SCN e I/e,"=l'-O" NOTE, QUANTITIES V<IILL VARY DEPENDING ON LENGTH OF PARKV<IAY PLANTING PLANTING SHALL BE MAINTAINED AT A MAX OF 30" HEIGHT FOR SIGHT VISIBILITY ALONG FARKV<IAY. TYPICAL CONCRETE --~ SIDEWALK DRIVEV<IAY 1/3 DISTANCE SIDEV<IALK 1/3 DIST ANGE KEY CD PLANTING TYPE 4 SPACING PER PLANTING KEYNOTES REFER TO PLANTING PLAN PLANTING TYPE 4 SPACING PER PLANTING KEYNOTES REFER TO PLANTING PLAN PLANTINS PER LESEND BARK MULCH TYPICAL SPACING ,J'ER LEGEND -+--~1j'- DRIVEAAY / / 1/3 DISTANCE VARIES REFER TO PLAN ROAD SMALL PARKWAY PLANTERS © PARK}1AY PLANTING 1YPICAL C,--------~ sc.u e I1e,•=I·-o· APPROVED FOR IRI\IGATION AND PLANTING ONL~ INCLUDING PRECISE LOCATION OF PLANTING AREA. DI """""'""'"loll RT DIAL TOLL FREE 1-800-422-4133 AT LEAST 1lNO DAYS BEFORE YOU DIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA DTL~2 "AS BUILT" REVIE,IED BY, INSPECTOR DATE DATE 6/16/26 l---+------+------------+--+-----,f-----,---1 I SH2E9ET 11 CITY OF CARLS BAD 5/05/26 . PLANNING DIVISION r--~===~;::::----1-1 _-_-_-_-... t _-_-_-_-+-I_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_--+t_-_-_-_-+-t _-_-_-_i_r _-_-_-_-+-I_-_-_-_,1 =L=AN=D=s=c::'.AP=E=IM=P=R=o=VE=M=E=N=T=P=L=A=N=s =F=o=R=· =====~1 DESIGNED BY: ~EE~-DATE: 04/21/2026 DRAWN BY: EE SCALE: PS INDICATED PROJECT MGR.: J. TAYLOR JOB NO.: 1765.01.1 POINSETTIA PROP£RTl£S {WATERS £ND} LANDSCAPE DETAILS I APPROVED~ 3== >------+---+-----------+-----+--+----+--.1 V 1£,Uf ~ 1) 11'{,Ztf PLANNING DATE l-----+--+-----------------+---+---1----+----I DATE INITIAL ENGINEER OF WORK Expiration Date: 10/31 /26 REVIS!ON DESCRIPTION DATE tNmAL DATE INITIAL O1HER APPROVAL Cl1Y APPROVAL OWN BY: ~E~E __ CHKO BY: =JT __ RVWD BY: PROJECT NO. LPC2026-0014, CT000016 DRAWING NO. 396-7T