HomeMy WebLinkAboutPRE 2026-0023; LUCIERNAGA TWIN HOMES; Admin Decision LetterJune 8, 2026
Murtaza Bahrami
3216 Rancho Campanero
Carlsbad, CA 92009
SUBJECT: PRE 2026-0023 (DEV2026-0037) -LUCIERNAGA TWIN HOMES
APN 215-310-05-00
{cityof
Carlsbad
Thank you for submitting a preliminary review application to subdivide a vacant lot into two lots and
develop the lots with an attached two-story twin home, with each lot sharing one common property line
(i.e., "zero lot line") and one common wall. The approximately 0.25-acre (11,177 square feet) site is
located on the north side Luciernaga Street, west of the intersection with Corintia Street, and outside of
the Coastal Zone.
In response to your application, the Planning Division has prepated this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans, policies, and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal, new plans, policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning:
General
1. General Plan and zoning designations for the property are as follows:
a. General Plan: R-8, Residential 4-8 du/ac
b. Zoning: R-2, Two-Family Residential
c. Master Plan: La Costa Master Plan (MP 149), R-2 designation
2. The project requires the following permits:
a. Minor Subdivision (MS, 4 or fewer units/lots)
b. Planned Unit Development {PD) to construct a twin home on individual lots.
The City Planner is the decision-making authority for the above-noted administrative permits.
3. Density. The proposal to develop the property with two dwellings has a proposed density of 8
dwelling units per acre {du/ac) and is therefore consistent with the R-8 General Plan Land Use
Designation, which permits a density range of 4-8 du/ac. •
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600
PRE 2026-0024 (DEV2026-0037) – LUCIERNAGA TWIN HOMES
June 8, 2026
Page 2 __________________________
Community Development Department
Planning Division 1635 Faraday Avenue Carlsbad, CA 92008-7314 442-339-2600
4. Citywide Objective Design Standards. Subject to the Carlsbad Municipal Code (CMC) Section
21.88, all projects that propose two or more attached dwelling units require compliance with the
city’s Objective Design Standards (ODS) standards. The Citywide ODS apply to this project. The
below-linked Objective Design Standards Manual Compliance Checklist is required with a formal
submittal. As elevations have not been submitted, compliance with the ODS cannot be verified at
this time.
Citywide Objective Design Standards Manual Compliance Checklist:
https://www.carlsbadca.gov/home/showpublisheddocument/15323/638411703853170000
Citywide Objective Design Standards Manual:
https://www.carlsbadca.gov/home/showpublisheddocument/13768/638860217609330000
5. Development Standards. Per CMC Section 21.45, Planned Developments, objective development
standards that are not addressed by ODS for twin-family homes must be met. This includes
building height, yards and setbacks, and lot size.
Please see link to CMC Section 21.45 for additional information: https://ecode360.com/44010002
6. Setbacks. Pursuant to CMC Section 21.45.070, the following setbacks apply to the lot:
a. Front: Luciernaga St – Setbacks from a direct entry garage must observe a 20-foot
setback from the front property line. The front yard setback currently complies.
b. Interior side yards: One side yard - 0 feet (the side yard where the dwellings on each
lot are attached). The other side yard setback shall be at least 20% of the lot width
and shall not exceed 20 feet. The proposal does not currently comply with this
requirement.
c. Rear: This property is considered a “through lot” due to it having frontage on both
Alga Rd and Luciernaga Rd. Therefore, the rear lot line will also need to observe a
front yard setback of 20 feet. The project is currently complying with this setback, but
the rear setback requirement needs to be relabeled on the plans to 20 feet.
7. Minimum Lot Size and Width. Pursuant to CMC Section 21.45.070, the following lot size and width
apply:
a. Lot size: The minimum lot area for twin homes is 3,750 square feet per lot. It appears
the proposed lot size is approximately 5,500 square feet, which would meet this
standard, but is not clearly dimensioned. Please include the square footage of each
lot and plot the parcel line separating the units on the site plan.
b. Lot width: Twin home projects require a lot width of a minimum of 35 feet per lot. It
appears the proposed width is approximately 42 feet, which would meet this
standard, but is not clearly dimensioned. Please include this measurement on the site
plan.
8. Private Recreation Space. Pursuant to CMC Section 21.45.070, Table D, Ref. No. D.11, the
following private recreational space requirements apply:
PRE 2026-0024 (DEV2026-0037) – LUCIERNAGA TWIN HOMES
June 8, 2026
Page 3 __________________________
Community Development Department
Planning Division 1635 Faraday Avenue Carlsbad, CA 92008-7314 442-339-2600
a. Minimum total area per unit: 400 square feet (may consist of more than one
recreational space). The project is currently meeting this requirement.
b. Minimum dimension of recreational space: 15 feet. The project is currently meeting
this requirement.
c. Required private recreational space shall be located at ground level and designed so
as to be functional, usable, and easily accessible from the dwelling it is intended to
serve, and shall not have a slope gradient greater than 5%. The project is currently
meeting this requirement.
d. Required private recreational space shall not be located within front yard setback
areas, and may not include any driveways, parking areas, storage areas, or walkways
(except those walkways that are clearly integral to the design of the recreation area).
The project is currently meeting this requirement.
9. Parking. Pursuant to CMC Section 21.45.070, the following parking requirement must be met:
a. Two spaces per unit, provided as either:
i. A two-car garage (minimum 20 feet by 20 feet), or
ii. Two separate one-car garages (minimum 12 feet by 20 feet each)
b. The project is currently meeting this requirement.
10. Height. Building height is determined by the underlying zone, Two-Family Residential (R-2). The
R-2 zone allows a maximum height of 30+ feet and two stories if a minimum roof pitch of 3:12 is
provided, or 24 feet and two stories if less than a 3:12 roof pitch is provided for lots under 20,000
square feet. As no elevations were provided, compliance cannot be verified.
11. Lot Coverage. Pursuant to CMC Section 21.45.070, Table D, Ref. No. D.3, maximum lot coverage
is determined based on the number of stories of the proposed residences. Since the minimum lot
size for the project as proposed is 3,750 square feet, the applicable lot coverage is 45%. Based on
the submitted plan, an approximately 1,980 square foot pad area on an approximate 5,550 square
foot lot (per twin home) is approximately 35%, which would meet the requirement. This is only
an estimate and would need to be clearly labeled and the calculation confirmed in future
submittals.
12. Inclusionary Housing. Please be aware that the proposal to create two units will require the
payment of an inclusionary housing in-lieu fee prior to recording the final map. The current fee is
$18 per square foot of net livable area (i.e., excluding garages). Please see link to the city’s
Informational Bulletin below for more information.
IB-157, Inclusionary Housing Program:
https://www.carlsbadca.gov/home/showpublisheddocument/9634/638938058103500000
13. Landscape Plan. A conceptual landscape plan shall be submitted with the project application in
compliance with the city's Landscape Manual and the standards set in the Objective Design
Standards Manual. Please note that the Parks Department may have additional requirements.
Landscape Manual:
https://www.carlsbadca.gov/home/showpublisheddocument/11160/637985942877070000
PRE 2026-0024 (DEV2026-0037) – LUCIERNAGA TWIN HOMES
June 8, 2026
Page 4 __________________________
Community Development Department
Planning Division 1635 Faraday Avenue Carlsbad, CA 92008-7314 442-339-2600
14. Noise Analysis. The subject parcel is located within the 60-65 and 65-70 dB(A) CNEL noise contour
lines of the Future Noise Contour Map. All residential lots and dwellings are to be sound
attenuated against present and projected roadway noise, which shall be the sum of all noise
impacting the project, so as not to exceed an exterior standard of 60 dB(A) CNEL (see Noise
Measurement Location in the Definitions Section for the description of Noise Measurement
Location) in outdoor living areas and an interior standard of 45 dB(A) CNEL in all habitable rooms.
Please submit a noise analysis of the project’s consistency with the General Plan and Noise
Guidelines Manual.
Noise Guidelines Manual:
https://www.carlsbadca.gov/home/showpublisheddocument/238/637425974092370000
General Plan, Noise Element:
https://www.carlsbadca.gov/home/showpublisheddocument/3426/637434861102600000
15. New requirements related to the city’s goals to reduce greenhouse gas (GHG) emissions will likely
impact development requirements of this project. A formal application submittal will need to
include a completed Climate Action Plan Checklist (Form P-30) to determine what requirements
will apply to the project. New GHG reduction requirements are related to energy efficiency,
photovoltaic, electric vehicle charging, water heating and traffic demand management
requirements, as set forth in the California Green Building Standards Code and in Carlsbad
Municipal Code Sections 18.21, 18.30 and 18.51 which is available on the city’s website at the
following address:
http://www.qcode.us/codes/carlsbad/view.php?topic=18&frames=on
To the extent that new GHG reduction requirements are in effect at the time of application for
grading or building permits, the project will be required to comply with the effective requirements
even if different than what is proposed in the project’s planning approvals. GHG reduction
Noise Co n o rs
Fu ureTrans-Noise-Contour
.2035 • ransi Noise Co our
60-65 C E
65-70 C IE
■ 70..-CNEL
PRE 2026-0024 (DEV2026-0037) – LUCIERNAGA TWIN HOMES
June 8, 2026
Page 5 __________________________
Community Development Department
Planning Division 1635 Faraday Avenue Carlsbad, CA 92008-7314 442-339-2600
requirements may impact, but are not limited to, site design and local building code requirements.
If incorporating new GHG reduction requirements results in substantial modifications to the
project after planning approvals are obtained, then prior to issuance of grading or building
permits, the applicant may be required to submit and receive approval of a Consistency
Determination or an Amendment application for the project through the Planning Division.
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
https://www.carlsbadca.gov/departments/community-development/planning. You may also access the
General Plan Land Use Element and the Zoning Ordinance online at the website address shown. Please
review all information carefully before submitting.
Land Development Engineering:
1. Complete a Stormwater Standards Questionnaire Form E-
34, https://www.carlsbadca.gov/home/showpublisheddocument/604/638683035715330000.
This questionnaire will guide you and the city in determining what type of reports and stormwater
mitigation must be completed to satisfy state and city stormwater quality requirements. The
questionnaire is located on the City of Carlsbad website. The plans do not show driveway
improvements, sidewalk replacement to current standards (6-ft sidewalk), or any other potential
patios, walkways, etc. If the project creates 10,000 square feet or more of impervious surfaces
collectively over the entire project site, a Storm Water Quality Management plan will need to be
prepared and submitted with the grading plan submittal.
2. Project plans shall show all source and site design BMPs on the conceptual grading and drainage
plans.
3. Provide a Preliminary Title Report (current within the last six (6) months).
4. Annotate and delineate all existing easements and encumbrances listed in the Preliminary Title
Report on the site plan. If any vacations or quitclaims are planned with this development annotate
on the site plan.
5. A Preliminary Hydrology Study, including map and calculations, is required to demonstrate the
capacity/sizing of proposed and existing storm drain infrastructure. Show 100-year storm
hydrologic calculations before and after development for each drainage basin.
6. A preliminary geotechnical report is required to evaluate the feasibility of the project and the
extent of earthwork (cut, fill, remedial grading). Guidelines for preliminary geotechnical studies
are available on the City of Carlsbad Engineering website through the following
link: https://www.carlsbadca.gov/home/showpublisheddocument/326/638054006747270000.
7. Grading quantities are not shown on the preliminary review site plan submitted. Please note, per
CMC15.16.060 this project will likely require a grading permit and grading plan.
8. A separate improvement plan for work within the right-of-way is required for this project. The
improvements include but are not limited to: removal and replacement of existing water service,
PRE 2026-0024 (DEV2026-0037) – LUCIERNAGA TWIN HOMES
June 8, 2026
Page 6 __________________________
Community Development Department
Planning Division 1635 Faraday Avenue Carlsbad, CA 92008-7314 442-339-2600
trench repair/AC resurfacing, ADA compliant driveway and replacement of existing sidewalk to 6-
ft sidewalk as per current Engineering Standards.
9. This project shall utilize City of Carlsbad Survey Control Network established on Record of Survey
Map 17271, NAD83, Zone VI, 1991.35 Epoch for horizontal control and NGVD 29 datum for vertical
control per City of Carlsbad Engineering Standards.
10. Delineate and annotate the limits of grading.
11. Delineate and annotate approximate topographic contours for existing and proposed condition.
Provide 1-foot contours for slopes less than 5%; 2-foot intervals for slopes between 5% and 10%,
and 5-foot intervals for slopes over 10%. Extend contours a minimum 25 feet beyond the project
boundary.
12. On the site plan, show and identify all existing surface improvements screened back (curb, gutter,
sidewalk, paving, manholes, inlets, street lights, adjacent driveways, vaults, transformers, etc.) at
the project site, project frontage and within 25 feet of the boundary. Utilize La Costa Meadows
Unit 2 record drawings available on the city’s website: DWG 172-6 (Public
Improvements) and DWG 172-6A (Grading).
13. Delineate location of all existing and proposed buildings, walls, fences and permanent structures
onsite and within 25 feet of the site.
14. Indicate the earthwork quantities (cut, fill, import, export, remedial) proposed for the project in
cubic yards.
15. Provide spot elevations at the corners of pad in the proposed condition. Include finish pad and
floor elevations.
16. Provide the method of draining lot. Unless otherwise specified by a geotechnical engineer,
method of drainage shall comply with California Building Code (latest version) section 1804.4.
17. Delineate all walls that will be utilized on the project site and show top of wall and bottom of wall
elevations, including at the highest and lowest points. Walls are measured from bottom of footing
to top of wall and maximum height measured from finish surface to top of wall.
18. Provide a cross section to show the existing and proposed ground, the proposed wall, the footing
and remedial excavation.
19. The project frontage has been identified in the city’s inventory as a vacant planting site.
Coordinate with the parks and recreation department for planting requirements per Section 11.12
of the Carlsbad Municipal Code for additional information.
20. Provide typical street cross sections for existing frontage streets (Luciernaga St and Alga Rd).
Provide existing right-of-way width and existing improvements and proposed improvements and
dedications.
PRE 2026-0024 (DEV2026-0037) – LUCIERNAGA TWIN HOMES
June 8, 2026
Page 7 __________________________
Community Development Department
Planning Division 1635 Faraday Avenue Carlsbad, CA 92008-7314 442-339-2600
21. Delineate and annotate all proposed driveways and driveway widths.
22. Show all existing and proposed utilities and callout size for: water, sewer, storm drain,
underground dry utilities, overhead lines, traffic signals, street lights in Luciernaga St and laterals
affecting the property.
23. Replace existing water service with a new PVC tee, meter and backflow per CMWD standard
drawing W-5.
24. Provide multiple cross-sections of the site to demonstrate differences in grade from adjacent
properties, existing and proposed grades on-site, fences and location of structures on-site and on
adjacent properties.
25. Coordinate with Leucadia Wastewater District since the proposed development is located within
their district for sewer service. This project will require their written approval.
26. Please be advised that a more in-depth review of the proposed development will occur with the
permit application when a more complete design of the project is provided.
Building:
1. New building is located in a Fire Hazard Severity Zone or Wildland Urban Interface Fire area shall
comply with 2025 CA WUI Code. Please note that building construction shall be in compliance
with Chapter 5. 2. Provide a completed Climate Action Plan (CAP) Consistency Checklists (city form
B-50). Address all elements on the plans.
Fire:
1. Parcel is located in a mapped High FHSZ. On the title sheet, please add a reference to another
applicable code: 2025 California Wildland-Urban Interface Code.
2. Dwellings shall be sprinklered throughout.
3. Fire department access is OK.
4. Defensible space is not required for this property mapped in the High FHSZ.
Public Works/Utilities:
1. Provide updated Civil Site Plan indicating utility connection locations, meter and backflow sizes,
and piping arrangements detailed up to the back flow preventers based on approved plumbing
and fire flow demands. All connections to the public utilities shall be detailed on plans in
accordance with current city engineering standards.
a. Plumbing analysis and Fire Department approved fire flow requirements shall be used to
determine the size(s) and number of potable water utility connections that are required.
b. Separate dedicated domestic potable water services for each unit.
PRE 2026-0024 (DEV2026-0037) – LUCIERNAGA TWIN HOMES
June 8, 2026
Page 8 __________________________
Community Development Department
Planning Division 1635 Faraday Avenue Carlsbad, CA 92008-7314 442-339-2600
2.Proposed Ground floor layout shall preserve suitable locations and space for all required utility
connections, meters, and backflow devices in conformance with current Engineering Standards.
Identify locations and detail fire service, water, irrigation, and sewer connections at property line
for the new development in compliance with current Carlsbad Engineering Design Standards.
3.Project is within Leucadia Wastewater District. Submit plans with Leucadia Wastewater District
for sewer review.
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
https://www.carlsbadca.gov/departments/community-development/planning/planning-applications-
forms. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the
website address shown; select Department Listing; select Planning Home Page. Please review all
information carefully before submitting.
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
contact Mackenzie VanZyverden at the email below. You may also contact each department individually
as follows:
•Planning Division: Mackenzie VanZyverden, Assistant Planner, at
Mackenzie.VanZyverden@CarlsbadCA.gov
•Land Development Engineering: Linda Ontiveros, Associate Engineer, at
Linda.Ontiveros@carlsbadca.gov
•Building Division: Jesse Sanchzes, Building Official, at Jesse.Sanchez@Carlsbadca.gov
•Fire and Life Safety Division: Darcy Davidson, Fire Chief, at Darcy.Davidson@Carlsbadca.gov
•Public Works/Utilities: Zac Taylor, Associate Engineer CMWD, at Zac.Taylor@carlsbadca.gov
Sincerely,
ROBERT EFIRD, AICP
Principal Planner
RE:MV:cf
c: Linda Ontiveros, Project Engineer
Laserfische/File Copy
Data Entry