December 3, 1993
ADL Planning Associates
5962 La Place Court, Suite 205
Carlsbad, CA 92008
Attention: Tony Lawson
SUBJECT: PRE 93-33 -CARL.5BAD LUTIIERAN HOMS
APN: 203-23f-t:ff 'MJfj 20i:232-15 J
Preliminary review of your project was conducted. Listed below are the issues raised by staff.
Please note that the purpose of a preliminary review is to provide you with direction and comments
on the overall concept of your project. The preliminary review does not represent an in-depth
analysis of your project. Additional issues of concern may be raised after your application is
submitted and processed for a more specific and detailed review.
It is apparent that Carlsbad Lutheran Homes is making a genuine and concerted effort to provide
the City of Carlsbad with a quality development while also attempting to satisfy CLH's requirements.
The proposed facility would offer senior residents many fine amenities, as well as provide Carlsbad
citizens a promenade to the beach and additional formalized beach parking. While the Professional
Care use at this location remains a desirable one, the issue of compatibility in the Beach Area
Overlay Zone/VR Zones is an extremely important one that the City cannot overlook. The scale
(height) and intensity (coverage) of the proposed development exceeds that which the City
considers to be consistent with surrounding development in both the BAOZ and VR zones.
The following issues addressing compatibility as well as other general issues and items that need
to be addressed prior to formal application submittal are offered to assist Carlsbad Lutheran in their
project redesign:
Planning Department
Compatibility
1. The project (Buildings 1, 2, and 3) exceeds maximum building height permitted in both the
BAOZ/R-3 and VR Zones. The proposed berms surrounding Buildings 1 and 3 do not allow
the lower level to qualify as basement units and building height is therefore measured from
existing grade. The height measurement along the west elevation of Building 2 also exceeds
30'. The Planning Department cannot make the necessary variance findings to permit
building height to exceed the standard for each zone and therefore cannot support the
project unless the project is redesigned to comply with maximum building height standards.
2. Compatibility concerns necessitate the provision of the required 20' minimum landscaped
setback along Ocean Street to reduce intensity of buildings at this location. Due to the
proposed intensity of the development, landscaped setbacks will ensure compatibility with
the surrounding residential development in the BAOZ.
2075 Las Palmas Drive • Carlsbad, California 92009-1576 • {619) 438-1161
PRE 93-33 -CARLSBAD L&ERAN HOME
APN: 203-231-01 AND 203-232-15
DECEMBER 3, 1993
PAGE 2
General Issues/Comments
3. In addition to the proposed benches and landscaping at the comer of Grand Avenue and
Carlsbad Boulevard, the Planning Department recommends an amenity such as a clock,
sculpture, fountain, or monument which focuses on Carlsbad's history.
4. The proposed island separating lanes at the Grand Avenue/Carlsbad Boulevard intersection
should be omitted to avoid the appearance of a private street.
5. Also of concern is the building facade of Building 3 facing Carlsbad Boulevard. This facade
should be designed to tie this segment of the development together with the main facility.
6. The proposed use will have to comply with noise standards through the submittal of a noise
analysis identifying exterior noise levels. The General Plan Update (Noise Element) likely
to be adopted identifies as conditionally acceptable an exterior noise level for this use of 65
CNEL. Interior noise levels may not exceed 45 dBA. It may be necessary to step the second
and third levels of Building 3 (south of Grand) back from Carlsbad Boulevard to achieve
this noise level.
7. In addition to the previous comments regarding environmental review of this project, a
cultural resource analysis of the existing CLH structure must be performed to determine its
historical status. If the proposed development represents a significant impact, the analysis
must include a recommendation of satisfactory mitigation.
8. The issue of unit classification must be resolved by the proposed zone code amendment in
advance of a decision on this project.
Engineering Department:
1. Please show all easements with future disposition, as indicated in a current Preliminary Title
Report (PTR). (Current PTR must be submitted with formal submittal application.)
2. Although the potential for full right-of-way width street vacation was previously discussed
for Christiansen Way, to accommodate for enhanced beach area circulation and to provide
for additional parking on Garfield Street staff recommends that a 24' ( curb to curb) alley
be constructed with a 5' concrete sidewalk within a 30' right-of-way at Christiansen Way
from Ocean Street to Garfield Street. Staff will require that agreement be obtained from
adjacent property owners (Best Western) to accommodate this design. If the adjacent
property owners do not agree with this design, then the proposed Christiansen Way alley
will have to be shifted southerly thereby impacting the proposed development.
In regards to any street vacations, please be advised that a street vacation application must
be submitted and signed by all of the involved property owners.
3. Please show courtyard drainage patterns and drainage facilities, i.e., sump drains and
failsafe overflow.
4. Please show handicap ramps at all intersections.
PRE 93-33 -CARLSBAD L-ERAN HOME
APN: 203-231-01 AND 203-232-15
DECEMBER 3, 1993
PAGE 3
5. Please identify rectangular areas shown on Ocean Street along the project frontage. If this
is proposed vehicular parking striping, please delete it. Parking stall striping is not required
in this area.
6. Please show all existing underground and overhead utilities, i.e., sewer, storm drain, water,
light standards, SDG&E, etc.
7. Please show existing and proposed topography and finished floor elevations.
8. Please show typical street sections for all of the roadways adjacent to the project.
9. Please indicate average daily traffic (ADT) generated by the project.
10. Please indicate grading quantities for the project, i.e., amount of cut/fill.
11. Please supply a striping plan for all legs of the Grand Avenue/Carlsbad Boulevard
intersection.
Underground Garage Issues
12. Circulation design of the underground parking garage is slightly confusing. Why cannot 90°
parking be put on the westerly side of the garage as well as on the easterly side? This
could create a standard two-way traffic circulation pattern and add more parking spaces.
Depending on whichever design is used, please redesign the corner parking spaces to
facilitate better vehicular ingress, egress and turning movements.
13. Please show the structure columns in the garage. Note that all parking stall dimensions
must be "clear" dimensions around these columns.
14. Please show garage drainage and garage water discharge location. Be advised, that National
Pollutant Discharge Elimination System (NPDES) criteria will be required for this project.
15. Please indicate percent grade of the garage driveway ramp.
16. Building and Fire Department staff were contacted regarding the underground garage and
the following are their comments:
• Building Department: Be advised that underground parking will
require substantial ventilation. Since this garage is entirely
subterranean, extensive ducting may be required. It is staffs
recommendation that prior to formal submittal the applicant contact
Mr. Mike Peterson of the Carlsbad Building Department for direction
on any building issues.
• Fire Department: The use of underground parking results in various
Fire Department personnel access issues. It is staffs recommendation
that prior to formal submittal the applicant contact Mr. Mike Smith
of the Carlsbad Fire Department for direction on any fire issues.
PRE 93-33 -CARLSBAD -HERAN HOME
APN: 203-231-01 AND 203-232-15
DECEMBER 3, 1993
PAGE 4
Please contact Anne Hysong at ( 619) 438-1161, extension 44 77 if you have any questions.