Loading...
HomeMy WebLinkAboutCDP 12-24; Board & Brew; Coastal Development Permit (CDP)201 OAK AVE SUITE E, CALSBAD, CA. 92008 SYMBOLS DETAIL NUMBER ~ -SECTION ~SHEET NUMBER DETAIL NUMBER . 2 ~ DETAIL A-4 SHEET NUMBER kDETAIL NUMBER B~ ~IN~TE=R~IO~R~E=LE=V~A~TI~ON~ \~SHEET NUMBER '\.._______ELEVATION NUMBER ~ 01.08' 107 KITCHEN AREA r0 0 DATUM ELEVATION DOOR NUMBER ROOM NUMBER & NAME KEYNOTE EQUIPMENT NUMBER ACCESSIBILITY NOTES 100410 ENTRANCES AND CIRCULATION 100410 1. TH£ TENANT SPACE, ALL 11> EXITS fROM THE BUILDING, THE PRIMAR"I PATH Of TRAVEL fROM THE ENTRANCE TG THE TENANT SPAC~ AND SANITARY FACIUTIES, DRINKING FOUNTAINS AND PUBUC TELEPHONES SE:RVING THE TENANT SPACE MUST BE ACCESSIBLE TO THE HI\NDICAPPED, SUBJECT TO FIELD VERIFICATION. 2. !.,JNIMUM MANEUVERING CL£ARANCE AT DOOR SHALL BE AS SHOWN IN FIGURES 11B-26A AND 118-268. TI-lE FlOOR OR GROUND AREA WITHIN THE REQUIRED CLEARANCES SHAU. BE LEVEL AND CLEAR. T~jE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF THE DOOR SWING OF AT LEAST 60 INCHES AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF +B INCHES AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. 1 1338.2.4.2 THE WIDTH OF TdE LEVEL AREA ON THE SIDE TO WHICH TrlE DOOR SWINGS SHALl EXTEND 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18 INCHES PAST TrlE STRIKE EDGE fOR ~TERIOR DOORS. 1133B.2.4.3 3. t.:·~TERIOR lAND:NG MAY SLOPE UP TO 1/4• PER FOOT IN Nrf DIRECTION FOR SURFACE DRAI~GE. 4. CLOSER-EFFORT TOP OPARAT£ DOORS. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5LBF FOR EXTERIOR .6ND INTERIOR DOORS, SUCH PULl OR PUSH EFFORT BEING .APPLIED AT RIGHT /'I.NGLES TO HINGED DOORS AND AT THE CENTER PLAN OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTIUZED TO MEET TI£ ABD\IE STANDARDS. WHEN fiRE DOOR ARE REQUIRED, lHE MAXlMJf.l EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM A.llOWABL£ BY TKE APPROPRIATE ADMINISTRATIVE AliTHORilY, NOT TO EXCEED 15 L.BF. 11338.2.5 "I'ND-ACTWATED DOOR OPENING HARDWARE, HANDLES, PULLS, LATCHES, LOCKS, /'ND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHAU. HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. HARDWARE SHALL BE CENTERED BETWEEN 30 INCHES AND 44 INCHES ABOVE THE fLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND WHICH ARE IN A PATH Of TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER-TYPE 1-IARDWARE, PANIC BARS,. PUSH-PULL ACWATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE. LOCKED EXIT DOORS SHALL OPERATE />S ABOVE IN EGRESS DiRECTION. 11338.2.5.2 5, r:1_00RS SHALL I-lAVE A NON-SLIP SURFACE. 6. THE INTERNATIONAL SYMBOL OF A.CCESSIBIUlY SHALl BE THE STANDARD USED TO IDENnFY FACIUTlES THAT ARE ACCESSIBLE TO AND USABLE BY PrlYSICALLY DISABLED PERSONS~ SET FORTH IN THESE BUILDING STANDA..R.DS AND JlS SPECIFICAllY REQUIRED IN SECTION 11178.5.8. SEE FIGURE 11 B-6. 11 1 78.5.8.1 THE SYMBOL SPEClFlED /IBOVE SJ-'ALL Cot~SIST Of A WHITE FliGURE ON A BLUE BACKGROUND. THE BLUE SHALl BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 5958. 11178.5.8.1.1 C:\ARACTERS, SYMBOLS AND THEIR B.6.CKGROUND SHALL HA.VE A NONGLARE FINISH. CHARACTERS AND SYI.IBOLS SKALi CONTRAST WITH THEIR BACKGROUND. EITHER LIGHT ON DARK BACKGROUND OR DARK ON LIGHT BACKGROUND. 1117B.5.2 CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HIEGHT R.'JIO Of BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HIEGHT RATIO Of BETWEEH 1:5 AND 1:10. 11178.5.J 7. DOORWAYS LEADING TO MEN'S SANITARY fACILITIES SHAIJ. BE IDENTIAED BY AN EQUILATERAL TRI/'NGLE, 1/4 INCH THICK WITH EDGES 12 INCHES LONG AND A VERTEX POINTING UPWARD. WOMEN'S SANITARY cACILITIES SHALL BE IDENTIAED BY A CIRCLE, 1/4 INCH THICK AND 12 INCHES IN DIA~ETER. UNISEX SI'NITARY FACILITIES SHALL BE UlENTifiED BY A CIRCLE, 1/4 INCH THICK, 12 INCHES IN D~METER WITH A 1/4 INCH THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12-INCH OlA.MfTER. THESE GEOMETRIC SYMBOLS SHALl BE CENTERED ON THE DOOR AT A HSIGHT OF 60 INCHES AND THEIR COLOR IND CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR PND CONTRAST OF THE DOOR. SEE . ~.LSO SECTION 11178,5.1, ITE~ I FOR ADDITIONAL SIGNAGE RIEQUIREI.IENTS APPLICABLE TO S.6.NITARY FACILmES. 111158.6 DINING FACILITIES 100410 GENERAL NOTES 091410 ---==-=:..::......::..=:..::.._:::.._==._....:.......:...-=-=-=::.....:=--------------....::.::..:....:..:..::...; 1. EACH DINING, BANQUET AND BAR AREA SHALL HAVE ONE WHEELCHAIR SEATING SPACE FOR EACH 20 SEATS, WITH AT LEAST 1. ALL WORK, INCLUDING MATERIALS AND WORKMANSHIP, SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES, LAWS, AND ORDINANCES AND AS SPECinED BY ALL GOVERNING AUTHORITIES WHERE APPLICABLE. REFERENCE IS TO THE LATEST ACCEPTED EDITION OR REVISION. IN THE EVENT OF CONFLICT WITH CODE REQUIREMENTS, THAT CODE REQUIREMENT OR NOTE WHICH ESTABLISHES THE HIGHER STANDARD SHALL TAKE PRECEDENCE. 2. THE INTENTION OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT, AND TRANSPORTATION NECESSARY FOR THE COMPLETE AND PROPER EXECUTION OF THE WORK. 3. THE CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BIDDING ANY PORTION OF THE WORK. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING WORK. SHOULD ANY CONDITION ARISE WHERE THE INTENT OF THE DRAWINGS IS IN DOUBT OR WHERE THERE IS A DISCREPANCY BE1WEEN THE CONTRACT DOCUMENTS AND THE FIELD CONDITIONS, OR WITHIN TilE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING IMMEDIATELY FOR CLARIFICATION. 4. DIMENSIONS ARE FROM FACE OF WALL OR TO CENTER OF WALL AS INDICATED ON ORP.WINGS, UNLESS NOTED OTHERWISE. 5. WRITTEN DIMENSIONS TAKE PRECEDENCE. DO NOT SCALE DRAWINGS. WALLS NOT DIMENSIONED ARE TO ALIGN WITH EXISTING WALLS OR BE ABUTTED OR APPLIED TO EXISTING WALLS PER DRAWINGS. DOORS NOT DIMENSIONED AND SHOWN JP.MB TIGHT SHALL BE SET 3" FROM PERPENDICULAR WALL TO OUTER EDGE OF DOOR JAMB. 6. REFERENCE TO ANY DETAIL OR DRAWING IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAILS OR DRAWINGS. 7. THE DESIGN, ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILI1Y OF THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILI1Y OF THE STRUCTURE AND PROVIDE NECESSARY BRACING PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, ROOF AND FLOOR DIAPHRAGMS, AND FINISH MATERIALS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. 8. THE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS, AS WELL AS THE DRAWINGS OF OTHER CONSULTANTS, ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILI1Y OF THE GENERAL CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF WORK SHOWN ON THE DRAWINGS OF CONSULTANTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCY BE1WEEN THE ARCHITECTURAL DRAWINGS AND THE DRAWINGS OF THE CONSULTING ENGINEERS TO THE ATTENTION OF THE ARCHITECT IN WRITING FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS AND NOT BROUGHT TO THE ARCHITECT'S AlTENTIDN SHALL BE CORRECTED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE AND AT NO EXPENSE TO THE OWNER OF ARCHITECT. 9. PRIOR TO PERFORMANCE OF WORK, THE CONTRACTOR SHALL REQUIRE EACH SUBCONTRACTOR TO I~OTIFY THE CONTRACTOR OF ANY WORK CALLED OUT IN THE DRAWINGS FOR HIS TRADE THAT CANNOT BE FULLY GUARANTEED. 10. CONTRACTOR SHALL VERIFY THE LOCATION AND SIZE OF ALL OPENINGS WITH ALL DRAWINGS AND MANUFACTURED ITEMS WHERE APPLICABLE. 11. THE ARCHITECT SHALL NOT HAVE CONTROL OVER OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFElY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH TiiE WORK, SINCE THESE ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY UNDER THE CONTRACT FOR CONSTRUCTION. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S SCHEDULES OR FAILURE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. THE ARCHITECT SHALL NOT HAVE CONTROL OVER OR CHARGE OF ACTS OR OMISSION OF THE CONTRACTOR, SUBCONTRACTORS, OR THEIR AGENTS OR EMPLOYEES, OR OF ANY OTHER PERSONS PERFORMING PORTIONS OF THE WORK. 12. THE CONTRACTOR HEREIN AGREES TO REPAIR OR REPLACE ANY OR ALL WORK, TOGETHER WITH ANY OTHER ADJACENT WORK WHICH MAY BE DISPLACED IN CONNECTION WITH SUCH REPLACEMENT, THAT MAY PROVE TO BE DEFECTIVE IN WORKMANSHIP OR MATERIALS WITHIN A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE, ORDINARY WEAR AND UNUSUAL ABUSE OR NEGLECT EXCEPTED. 13. CONTRACTOR SHALL PROTECT ALL EXISTING STRUCTURES, LANDSCAPING, MATERIALS, ETC., DURING CONSTRUCTION. CONTRACTOR SHALL PATCH AND REPAIR ALL SURFACES DISRUPTED OR DAMAGED DURING CONSTRUCTION TO MATCH EXISTING ADJACENT SURFACES. 14. THE CONTRACTOR SHALL ON A DAILY BASIS KEEP THE PREMISES FREE FROM ALL ACCUMULATIONS OF WASTE MATERIAL OR RUBBISH CAUSED BY HIS EMPLOYEES, SUBCONTRACTORS, OR WORK, AND AT THE COMPLETION OF THE WORK SHALL REMOVE ALL RUBBISH, DEBRIS, EQUIPMENT, AND SURPLUS MATERIALS FROM IN AND ABOUT THE BUILDING AND LEAVE THE PREMISES "BROOM CLEAN". 15. ANY DEVIATION FROM THE CONSTRUCTION DOCUMENTS OR SPECIFICATIONS BY THE CONTRACTOR OR OWNER WITHOUT THE ARCHITEcrs APPROVAL IN WRITING RELEASES THE ARCHITECT OF RESPONSIBILilY AND LIABILilY IN CONNECTION WITH ALL WORK SO INVOLVED. 16. CLARIFICATIONS ON AND/OR INCONSISTENCIES WITH THE DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATIENTION OF THE ARCHITECT BY THE CONTRACTOR PRIOR TO COMMENCEMENT OF WORK. ADDITIONAL CHARGES WILL NOT BE GRANTED BASED ON CLAIMS OF INCOMPLETE, INACCURATE, OR INCONSISTENT DRAWINGS AND SPECIFICATIONS. CNE IAINIMUM WHEELCH.AJR SEATING SPACE PER FUNCTIONAL AREA. SUCH SEATING SHALL BE DESIGNED AND ARRANGED TO P'RMIT USE BY WHEELCHAIR OCCUPANTS, AND SHALL COMPLY WITH SECTION 1122B, fiXED OR BUILT-IN SEATING, TABLES, AND COUNTERS. ACCESS TO SUCH SEATING SPACES SHALL BE PROVIDED WITH MAIN .AJSLES NOT LESS THAN 36 INCHES CLEAR '." ilTH. IN ESTABLISHMENTS WHERE SEPARATE AREAS ARE DESIGNATED FOR SMOKING AND NONSMOKING PATRONS, THE REQUIRED ~''IMBER Of ACCESSIBLE FIXED TABLES (OR COUNTERS) SHALL BE PROPORTIONALLY DISTRIBUTED BEnVEEN THE SMOKING AND NONSMOKING AREAS. ACCESSIBLE SEATING SPACES SHAI! BE INTEGRATED WITH GENERAL SEATING TO ALLOW A REASONABLE SELECTION OF SEATING AREA AND TO AVOID HAVING 01>1 AREA SPECIFICALLY HIGHLIGHTED />S THE AREA FOR PERSONS WITH DISABIUTIES. THE RATIO Of P.CCESSIBLE SEATING IS BASED ON TiiE TOTAL NUMBER OF SEATS PROVIDED. WHERE FLOOD OR lRINK IS SERVED AT COUNTERS EXCEEDING 34 INCHES IN HEIGHT FOR CONSUMPTION BY CUSTOMERS SEATED OR STANDING II THE COUNTER, A PORTION OF TiiE M.AJN COUNTER I~HICH IS 6D INCHES IN LENGTH MINIMUM SHALL BE PROVIDED IN COMPLIANCE WITH SECTION 1122B. 1104 B.5( 4) 2. KNEE SPACE FOR WHEELCHAIR SEATING IS 27" MAX. HIGH X 30' WIDE X 18' DEEP. THE MAX. HEIGHT Of THE TABLE TOP IS BETWEEN 28" -34". 3. T.\BLEWARE, DISHWARE, CONDIMENTS, FOOD. BEVERAGE DISPLAY SHELVES SHALL COMPLY WITH SECTION 1122B.4. SEE fiGURE 11 B-17. 4. KITCHEN SINKS ARE REQUIRED TO HAVE A LEVER, PUSH JYPE OR ELECTRONICALLY OPERATED FAUCETS, WITH A 5 LB. MAX OPERATING FORCE. SELF CLOSING fAUCETS SHALL REMAIN OPEN 10 SECONDS MIN. SECTION 1115B.4.7. SANITARY FACILITIES 100410 I. RESTROOM$ SHALL MEET ACCESSIBILITY STANDARDS AS DEFINED BY SECTION 1115B. 2. TOILET AND URINAL FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44 INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. 3. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. 4. cAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS PER FOOT. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE: EXAMPLES Of ACCEPTABLE DESIGNS. SELF CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 5. THE STRUCTURAL STRENGTH OF GRAB BARS, TUIB AND SHOWER SEATS, FASTENERS, AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS, !1115B.7.21 A. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION OF A 250-LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT. !1115B.7.21111 B. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250-LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT, AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES SHALL NOT !EXCEED THE ALLOWABLE SHEAR STRESS. 11115B.7.21211 C. SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICES FROM THE APPLICATION OF A 250-LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE LOAD. 11115B.7.2.1311 D. TENSILE FORCE INDUCED IN A FASTENER B.Y A DIRECT TENSION FORCE OF A 250-LB POINT LOAD, PLUS THE MAXIMUM M0~1ENT FROM THE APPLICATION OF A 250-LB POINT LOAD, SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND SUPPORTING STRUCTURE. 11115B.7.214)) · E. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. II115B.7.2151) 6. LOCATE FLOOR DRAINS SO AS NOT TO INTERFERE WITH A LEVEL PATH OF TRAVEL TO AND AROUND ALL FIXTURES. ELECTRICAL 100410 I. TilE CENTER OF JUNCTION BOX FOR ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLE OUTLETS SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION MEETINIG THE CLEARANCES AND REACH RANGE REQUIREMENTS OF SECTION IIIBB AND NOT 11117B.6.3 a 3·210-7IG.III LESS THAN 15" ABOVE THE FLOOR OR WORKING PLATFORMS. 2. THE CENTER OF THE GRIP OF THE OPERATING H.ANDLE OF CONTROLS OR SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO COI'ITROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING, AND VENTILATING EQUIPMENT SHALL MEET THE REQUIREMENTS OF PART 2, CALIFORNIA BUILDING CODE ICBCI, SECTION IIIBB, SPACE ALLOWANCE AND REACH RANGES, FOR PERSONS WITH DISABILITIES AND SHALL NOT BE MORE THAN 46" ABOVE THE FLOOR OR WORKING PLATFORM. ABBREVIATIONS A.C. ASPHALTIC CDNCRfTE A.F.F. ABOVE FINISHED FLOOR AC.T. ACOUSTICAL TILE ADMIN. ADMINISTRATION BLD'G BUILDING B.N. BULL NOSE B.L. BUILDING UNE C.B. CHALK BOARD GEM. CEMENT GEM. PLAS. CEMENT PLASTER C.F. CUBIC FEET CL'G CEILING CLSR'M CLASSROOM CLR CLEAR CMU CDNCRfTE MASONRY UNIT CONC. CONCRfTE C.T. CERAMIC TILE DET. DETS DIA (E) EXISrG EL. ELEV. E.P. EQ. F. G. F.H.C. nN • FLR FTG GA. GALV GYP. BD. DETAIL DETAILS DIAMETER EXISTING EXISTING ELEVATION ELEVATION, ELEVATOR ELECTRICAL PANEL EQUAL FINISH GRADE FIRE HOSE CABINET FINISH, FINISHED FLOOR FOOTING GAUGE GALVANIZED GYPSUM BOARD SITE PLAN (E) WATER MAINE __ _.- FOR OUR USE ONLY (E) GAS METER ----' (E) SEWER LINE __ / CLEAN OUT EXISTING TRASH ENCLOSURE ~ I.J.J ~ I- V') z _J 0 u z -_J MAX. MIN. M.B. MET. (N) N.I.C. NO. D.C. D.O. DPEN'G OPP. PL PLYW'D PR. REQ. S.F. SHT SIM. S.S., ST.S. s. STRUC. T.O. T.A. T.B. T.C. T.W. lYP. U.N.O. V.C.T. VERT. VEST. MAXIMUM MINIMUM MARKER BOARD METAL NEW NOT IN CONTRACT NUMBER ON CENTER OUTSIDE DIAMfTER OPENING OPPOSITE PLATE PLYWOOD PAIR REQUIRED SQUARE FEET SHEET SIMILAR STAINLESS STEEL STANDARD STRUCTURAL TOP OF TOP OF ASPHALT PAVING TACK BOARD TOP OF CONC., T.O. CURB TOP OF WALL lYPICAL UNLESS NOTED OTHERWISE VINYL COMBINATION TILE VERTICAL VESTIBULE SCALE: 1/16"~1'-0" -+tt-H-tt-DN (E) STAIRS <.n I. 0 • 10'-o" 9'-6" 8'-6" B'-6" "' I. o, CITY OF CARLSBAD Administrative Permit c~; ~; · · · g;· · lt.; Jo · · · · · · · · · · · · · · · · · · -~--------~--~·-k·-~-----·-····· -----·· E1Jlibit No. :4 ' ( Date f[i ZU, I 3 SHEET INDEX VICINITY MAP T -1.0 INDEX NOTES, PROJECT INFO, VICIN11Y MAP, SITE PLAN T -1.1 GENERAL NOTES T -1.2 GENERAL NOTES T -1.3 ACCESSIBILI1Y NOTES T-1.4 ACCESSIBILI1Y DETAILS T -1.5 ENVIORMENTAL HEALTH NOTES & PARKING ANALYSIS A-1.0 FLOOR PLAN AND ROOM FINISH SCHEDULE A-1.1 REFLECTED CEILING PLAN & SCHEDULE A-3.0 DETAILS A-3.1 DETAILS K-1.0 EQUIPMENT PLAN & SCHEDULE E -I GENERAL NOTES, SCHEDULE, LEGEND, AND SINGLE-LINE DIAGRAM E-2 LIGHTING PLAN & TITLE 24 E-3 POWER PLAN M-0.0 MECHANICAL NOTES, SCHEDULES AND ABBREVIATIONS M-1.0 MECHANICAL FLOOR AND ROOF PLAN M-2.0 MECHANICAL DETAILS M-3.0 HOOD DETAILS M-3.1 HOOD DETAILS M-4.0 TITI£ 24 M-5.0 TITLE 24 M-6.0 TITLE 24 M-7.0 TITLE 24 P-1.0 GENERAL NOTES, LEGENDS, & SCHEDULE P-2.0 WATER & GAS PLAN, WASTE & VENT PLAN P-3.0 PLUMBING DETAILS *201 OAK AVE SUITE E, CALSBAD CA 92008 PROJECT SUMMARY PROJECT ADDRESS: 201 OAK AVE SUITE E CALRSBAD, CA. 92008 PROJECT DESCRIPTION: TENANT IMPROVEMENT OF A RESTAURANT OF IN AN EXISTING TENANT SPACE. CODE ANALYSIS: 2010 CALIFORNIA BUILDING CODE 2010 CALIFORNIA MECHANICAL CODE 201 0 CALIFORNIA ELECTRICAL CODE 201 D CALIFORNIA PLUMBING CODE 201 D CALIFORNIA FIRE CODE 201 D CALIFORNIA ENERGY CODE DEFERRED SUBMITIALS: CONSTRUCTION TYPE: V-NON SPRINKLER NO. OF STORIES: OCCUPANCY: T.l. AREA OF WORK: NO. OF EMPLOYEES: OCCUPANT LOAD: 1-STORY B 1237 SQ.FT. 4 MAX. PER SHIFT CUSTOMER AREA SERVICE AREA KITCHEN/PREP . 672 S.F /15 = 45 G6.75 S.F /100 ~ 1 2:6.82 S.F /200 ~ 2 TOTAL DCC UP ANT LOAD: NO. OF EXIT REQUIRED (BEW/1 50 DCC.) NO. OF EXIT PROVIDED EXIT WIDlH CALCULATION: REQUIRED EXIT = TOTAL OCCUPANTS X .15 .15 ~ 48 ARCHITECT: GARY WANG 1255 CORPORATE CENTER DR., SUITE 8, MONTEREY PARK, CA 91754 PH: (626) 288-6898 FAX: (626) 768-7101 TENANT: CLAYTON WHEELER 760-519-2169 BOARD AND BREW 201 OAK AVE SUITE E CARLSBAD, CA. 92008 /---?,-,,~~--o, ~, ,..-- / ,' / / .. / .. .. : 7 ELEVEN LEVELED I ICE CREAM/ BOARD 8: YOGURT BREW RESTAURANT TOTAL AREA~ 1237 SQ.FT. ' ,c / ' ' ,' ,-· ,' /1" ,' .. --,' ,' .. ' .. ' '' / / / I ' ' ' ' ' ' /, ,-_ , __ -·_.-,·1\pJ .>·-_, -· , __ , __ ->-_,, P,ROPERT'/-<,/_/ :/ , / <-Not/PARt/>/ - ""'~--..l,,..----r----L--------....L.+~,...,r------rl / ,' / /' '.. .... ' .. --' _.... / ' .... / .. B'-6" 8'-6" ACCESSIBLE PATH OF ADA PARKING ACCESSIBLE PATH nc _ __..,--- TRAVEL FROM PUBLIC STREET. MAX. 5% SLOPE & MAX. CROSS SLOPE OF 2%. 8'-6" 6'-10" LIEVEL LANDING MAX. 2% SLOPE ANY DIRECTION B'-6" s'-6" s'-6'~ s'-6" a·-s· s'-6" 10'-o" ' ' / ' ' ' ' / / ' ' ' ' ' ' .' .' !" .. / / ' / ' ' ' ' ' ' ' ' ' 17. THE ARCHITECT SHALL REVIEW OR TAKE OTHER APPROPRIATE ACTION UPON CONTRACTOR'S SUBMITIALS SUCH AS SHOP DRAWINGS, PRODUCT DATA AND SAMPLES, BUT SHALL DO SO ONLY FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE CONTRACT DOCUMENTS. REVIEW OF SUCH SUBMITIALS IS NOT CONDUCTED FOR THE PURPOSE OF DETERMINING THE ACCURACY AND COMPLETENESS OF OTHER DETAILS SUCH AS DIMENSIONS AND QUANTITIES DR FOR SUBSTANTIATING INSTRUCTIONS FOR INSTALLATION OR PERFORMANCE OF EQUIPMENT OF SYSTEMS, ALL OF WHICH REMAIN THE RESPONSIBILilY OF THE CONTRACTOR. THE ARCHITECTS REVIEW SHALL NOT CONSTITUTE ACCEPTANCE OF SAFElY PRECAUTIONS OR, UNLESS OTHERWISE SPECIFICALLY STATED BY THE ARCHITECT, OF ANY CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES. LANDSCAPING LANDSCAPING 3. THE CENTER OF FIRE ALARM INITIATING DEVICES IBOXESI SHALL BE LOCATED 48" ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE, OR SIDEWALK. SEE SHEET T -1.5 FOR PARKING ANALYSIS 5.0' WALK WAY OAK AVE NORTH ~ TritS£ Oi!AVIIIOS I.NIJ 5'WflCAll0115 N«l IPUS, 111'511:115 00 l.llRAI!<am~rs Ra'RC>e>~TID Jl£f£8Y ......: oo guu. rctW.t~ f>£ PllOI'EIIIY OF ll\'1'1' 'liANG Ill ...SSOQ.I.Q AAO ~0 rllllT iHOWJ' iiH.'IJ. Ell: CCPIOD, Ol:iCU)SOI) W CTHE!l~ ~ 11:0 I~ xtjNECT!Cfl YII1H AN~ IIOik Oil PRoJECT OI'£11 '!hAN ll1~ SPECI~C PR:J.Eel fOil YIHI~ lHEf IIA\'E aut~ ?1\W/\IIfD oo O!olf.I.U"E[l wmM IJI( lftll£1< CO!IIt/IT or G.VJY WJ..Ij~ l ASS~AlU. V.SUN-CONTACT \\'l1ll lHESE DIV.~OS .I.~D !i'tan::Allll.'li SIIAU. CllNS1111J1t W!ICLUSilt tWIW<:t OF lH~ IIE>!RIC~[lll!l \lfllfll)j 011m<SKt15 ~ ne;E ORA\ItllG>i !iWJ. ~4\'1: Plii:CE!:ONI:I: 0\Pl ~ O~!l(ft$; CallllAtTtll9 SII.'IJ. 'oWY, HlC « m:S/'0/l;>OU: fQ'I A1l. ~ll:tiSIOH:i NlD crl>IOJlKIHll C1o1 Til' .re_ Nil 1HI' t:fflct WU5f !II: ~OllrFn OF .oflT V.o.HIW~S tllilN lH~ PIIOUIS!Dll5 mP ~110.45 il:IO\Ij BT TIICII:: OIIAII.IIOS. SliCII' otl.\II.IIUST IIi: SUillollltD W 1Hl!i Offl!:E Fell I!EYIEII' BUURE PR<ItllillfW \!illli1H~ f...a/UCAll.:ii. ;: w 0: Ol c z <C JS co 0 0 N 0) JOB NUMBER 12-108 BUILDING CORRECTIONS HEALTH DEPT. CORRECTIONS SHEET CONTENT INDEX NOTES, PROJECT INFO, VICINITY MAP, SITE PLAN SHEET NUMBER T-1.0 ~-~-- POLICIES AND PROCEDIRES FOR ROOFTOP MOUNTED EQUIPMENT CITY OF CARLSBAD POLICIES AND PROCEDURE NUMBER: 80-6 SUBJECT: ROOF MOUNTED EQUIPMENT I-E:.:F...:.F..:E..:C..:..TI:.:.V;:E::..,:5::_/1::.:/9:.:2:__ ____ -J SECTION: BUILDING DEPARTMENT SUPERSEDES: 80-6(9/1 0/80) 80-6(5/01/81) PURPOSE: PROVIDE INsTALlATION STANDARDs FOR ALL ROOF MOUNTED EQUIPMENT AND PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGs. INTENT: A. Maintain roof integrity. POLICY; B. Prevent hazardous condition to firemen who must fight fire on the roof. C. Provide an installation that is aesthetically sensitive to the building and the adjoining properties. 1. 2. 3. 4. 5. 6. 7. All equipment shall be concealed from view and the design* shall meet the approval of the Planning Department. All equipment shall be specifically designed and approved for exterior use and shall be approved by the City of Carlsbad Building Department. All roof mounted equipment shall be on a platform which shall be an integral part of the roof-flashed and waterproofed. When a screen is approved, it shall have .as few roof connections as possible and be structurally adequate. All electrical, plumbing, mechanical duct work and related piping shall be inside the building and not on the roof. All connections related to equipment shall be made in the same roof opening on the pliltfonn or h!'lve the prior approval from the building official, Sewer vents shall be brought to one main vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity. Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrooms and other equipment are back to back or in general proximity. . Existing buildings and equipment, remodel or replacement, shall meet thoo above regulations or shall have the prior approval from the building official. Where new equipment is installed, unused or abandoned equipment, including all roof mounted piping, electrical, mechanical, duct, and other related appurtenances shall be removed from roof and unused op\'lnings properly sealed to maintain roof integrity. •The architect should, through design, conceal the heating/AC unit and other equipment whether they are on the roof or el~>ewhere. Initiated By: Approved By: · ENVIORNMENTAL HEALTH NOTES Environmental Health Notes The following Environmental Health notes are to be placed on your plans to assist In providing clear direction between those involved in the actual construction of a food facility including contractors and Environmental Health Specialists. These notes will encompass most food facilities but are not meant to be comprehensive for all food facilities or situations: 1. A concrete slab is provided for trash, garbage, and grease container. If walls enclose area, the interior wall surfaces will be smooth, sealed and washable (e.g., plastered smooth and painted, etc.). 2. All food-related and utensil-related equipment shall meet or be equivalent to sanitation standards established by an American National Standards Institute (ANSI) accredited program. 3. All floor mounted equipment will be installed on minimum 6" sanitary legs, castors, or completely sealed in position on a 4 ·high curb with continuously caved base. Countertop equipment will be on 4-inch sanitary legs or sealed to the counter unless readily movable. 4. If soft drink, ice or other dispensers are self-service, or If refills are provided they must be push button types, or lever types where the lever contacts the container at least one inch below the rim. 5. Any openable windows vent openings or other similar openings must be provided with tigl1t fitting screens of minimum 16-mesh to the inch. Windows to be fixed at food prep, utensil-washing, open food and utensil storage areas. 6. All exterior doors open outward and are self-closing and tight fitting. 7. Bi-fold, French, accordion style and roll-up doors cannot open into the food prep, utensil washing or unpackaged food service areas. 8. Toilet room and dressing room doors must be self-closing, tight fitting. 9. Delivery doors to have air curtain fans that span the width over the door. The fan must activate via a microswitch providing a minimum velocity of 1600 fpm measured 3 feet above the ground. 10. A minimum of 10 foot-candles of ligh1 measured 30" off floor is provided in walk-in refrigerated storage and dry storage rooms and at least 20-foot candles is provided where food is provided for consumer self-service, where fresh produce or prepackaged foods are sold or offered for consumption; inside equipment such as reach-in and under-counter refrigerators; In areas used for handwashing, warewashlng, equipment and ulensil storage, and in toilet rooms. 11. A minimum of 50 foot-candles of light measured 30" off fioor is provided when working with food or working with utensils or equipment such as lm!ves, slicers, grinders, or saws where employee safety is a factor and in all areas during periods of cleaning. 12~ Shattershields for all lights above food preparation, work, and storage areas will be provided. 13. All warewashing sinks to have 3 comparlments that are a minimum size of at least 1B"x1B"x12" deep (or 16"x20"x12" deep) with a minimum 18" drainboard at each and. If against a wall, it must have an a· integral backsplash. However, it must be capable of accommodating the largest utensil to be washed. A warewashing machine does not substitute for the sink requirement. 14. Sinks to have spout(s) capable of reaching each compartment. 15. Food prep sink compartment(s) to be at least 18"x18"x12" deep (or 16"x20"x12" deep) with a minimum 1 B" drainboard. Separate food prep sinks to be provided for meats and produce. 16. The 3 or 4 compartment bar sink to be at least 12"x12"x10" deep (or 10"x14"x10" deep) with a minimum 18" drain board at each end. 17. A separate wet waste dump fixture shall be provided for disposal of drink or waste ice or coffee waste. 18. Each handwashing sink must have permanently mounted single-service soap and paper towel dispensers. SCREENING OF EQUIPMENT Exterior com:ponents of plumbing, processing, heating, cooling, and ventilation systems (iilcluding but not limited to piping, tanks, stacks, collectors, heating, cootlng, and ventOstlng equlpmt;nt fan!!l, blowers, ductwork, vents, louver, meters, com~ressors1, motors, Incinerators, ov~ns, etc ... ) shall not be directly visible from a height of five feet from the closest bulldmg wall on any IDL Scaled elevations of all such equipment, as well as screening materials, are required on alt site plans. See example below. EXAMPLE OF SCREENING MATERIAL DISPLAY EAL TH DEPT. NOTES 1. lYPE OF FOOD F:ACILilY-FAST CASUAL RESTAURANT (SINGLE-SERVE UTENSILS ONLY) 2. THIS FOOD FACIL.IlY WILL BE SERVED BY CllY OF CARLSBAD WASTEWATER DIVISION & CARLSBAD MUNICIPAL WATER DISTRICT 3. EXISTING TRASH ENCLOSURE: A CONCRETE SLAB IS PROVIDED FOR TRASH, GARBAGE AND GREASE CONTAINER STORAGE. THE INTERIOR WALL SURFACES ARE SMOOTH, SEALED P.ND WASHABLE (E.G., PLASTERED AND PAINTED, ETC.) 4. ANY OPENABLE ~VINDOWS , VENT OPENINGS OR OTHER SIMILAR OPENINGS MUST BE PROVIDED WITH TIGHT -FITIING SCREENS OF MINIMUM 16 MESH. WINDOWS TO BE FIXED AT FOOD PREP, UTENSIL-WASHING, OPEN FOOD AND UTENSIL STORAGE AREAS. 19. The hot 1water heater will be a commercial type capable of constantly supplying hot water at a temperature of 12D'F to all sinks. In sizing the water heater, the peak hourly demand for all sinks, etC.1 are added together to determine the minimum required recovery rate. 20. Alllavatowies or hand sinks will have a combination faucet or premixing faucet capable of supplying water tempered to 1DO'F. Self~dosing or metered faucet to provide at least 15 seconds of water without reactivation. 21. All plumbing, electrical and gas lines shall be concealed witl1in the building structure to as great an extent as possible. All exposed conduits, plumbing, etc. shall be installed at least 6" off floor and 314" from walls using standoff brackets. 22. Conduits, plumbing or piping cannot be installed across any aisle way, traffic area or door opening. 23. Multiple runs or clusters of conduit or pipelines shall be furred in or encased in an approved sealed enclosure. 24. All liquid waste shall be drained by means of indirect waste pipes into a floor sink. Floor sinks are to be installed flush wilh the finished floor surface and have suitable easily removable safety cover grates. 25. Floor sink to be 50% exposed when no access is provided for cleaning or be in line with the front face of elevated freestanding equipment. 26. Approved backflow prevention devices shall be properly installed upstream of any potential hazard between ·ihe potable water supply and a source of contamination. Hoses shall not be attached to a faucet or hose bibb unless an approved backflow preventer is provided. 27. Water supply to carbonators shall be protected by an approved reduced pressure principle backfiow pre venter. The relief valve shall drain indirectly to sewer with a legal air gap. 28. For cleaning floor mats, the janitorial sink to be a minimum 24" by 36" floor-mounted type. Mops shall be placed in a position that allows them to air·dry without soiling walls, equipment, or supplies. 29. The janitorial sink faucet will have a threaded outer lip for hose attachment and an approved backflow prevention device. No chemical dispensing systems or shutoff valves to be attached to mop sink faucet outlet (unless a "sidekick" plumbing device is installed). 30. No condensate or wastewater including HVAC will drain into the janitorial sink. 31. Grease trap to be located outside the food service activity area, flush with the finished floor when indoors. tocal wastewater district or building department to be contacted for grease removal requirements. 32. Floor drains shall be installed in floors that are water-flushed for cleaning and in areas where pressure spray methods for cleaning equipment are used, in restrooms, janitorial rooms, sculleries, and at bars with warewashing. Floor surfaces in areas pursuant to this shall be sloped 1 :50 to the floor drains. 33. Adequate ventilation is to be provided to all toilet rooms, janitor closets with mop sinks, and indoor trash rooms and in dressing/change room(s). 34. The floor finish will have a smooth surface under all equipment and walkways will have a light texture only. 35. The paint used on walls and ceilings of all kitchen, food preparation, work, and storage areas will be a gloss or semi-gloss enamel. Finish material shall be a light color in food prep areas for easy cleaning. 36. Prior to installation, samples of finishes to be submitted to Environmental Health for approval as needed. 37. Cold storage rooms shall be provided with a section of shelving installed to hold shallow cool down pans -nol to exceed 4" in height. Space between shelving to be at least 8" high. 38. Backup dry storage shelving shall be a minimum of 96 linear feet (measured with tiers) or 25% of kitchen, food prep, and work areas, whichever is greater. Shelving shall be at least 18 inches deep and start a minimum six inches off the floor surface. 39. Shelving over wet areas (sinks, mop sinks etc.} and food prep surfaces will be metal. 40. All seams, gaps, openings to be properly sealed. 2 PARKING ANALYSIS ) BUSINESS NAME NET SQUARE FEET GROSS SQUARE FEET PARKING RATIO SPACES REQUIRED 7-11 2672 SQ. FT. 3356 SQ. FT. 1/200 SQ. FT. 13 ICE CREAM/YOGURT 1000 SQ. FT. 1095 SQ. FT. 1/300 SQ. FT. 3 BOARD AND BREW 954 SQ. FT. 1147 SQ. FT. 1/100 SQ. FT. 1D TOTAL SPACES REQUIRED: 26 PARKING ANALYSIS PLAN: FOR REFERNECE ONLY SCAlE: 1 /16" 1' 0" -r-------------~ 90'-0" 29'-8" ,------~ {E) OUTSIDE SPACE • 0 I 0 ..,. ~ ,.: I~ - b . lt> (E) TRASH [IOCLOSURE 1-- IJJ IJJ a:::: 1- U1 z _.J 0 u z -_.J LANDSCAPING LANDSCAPiNG ,,~ -~ 5.0' WALK WAY ------------------~- OAK AVE , , ADJ. , , -· ' ' . P'ROPERTY ,, NOT PART lliE!f: (IR~YIING!i ~.., ,.P[W"l(Ali:..IS Ahll JtiU.S, DrSiii/IS IJO I.~RI.WOEIENTS fi£F'RE5EHTEO TH£1£BT /lit£ ~D ~l.ll ~[i.ll.l"l 1lli: PRDP<RTY CF [;AA~ WI.Nii & IISSOCIO.lE'5; 1.NU NO fiJH lllllll:Of :i!IAU. Dt co."lll. D~ TD OliO~ M USCO 1"1 CO~I>ECTIO~ "'nl 1m \110111<, 00 Pflo.JECT 01\£R ~o\11 TIE SI'Ec;fl" PROJECT FOR. Wr111:11 TH[Y H~I'E 11[01 Pllfi'~RW /JIO DE\IJ.JlP£11 1'1\HOOT 11£ il!lml< OO'!WIT Ill" G/J!Y WAlll & liS~ I. liS 11SJ.II. cot. MCT \\011 lHE51' PRMINO~ AWl >PEI:Fic..\~~li SHIO.L C~SliT\IllO C~U.·SII'> -~~l'lil'l' D'" llltst Rll"IRICrJQfl. ~TOJ DNillt.OlS 00 "KSE DfM\'1\N~~ Slt.W. ~~If PI!OI:f:IIDIIX OlD SCI.WI ).UDI~OHS; a;.,IR/ICIDiS 5/tJ.JJ. ,piFY, ..no liE ~(lf-1>!81.E fOO AU DI'IDIS.OII> AAD CO'IOITI:ltlli ~ THE JOB, AAII THS CffiCE MUST a!' f!Clln•o Of ~y VAftl~110~> F1la.l 1m" DMQIS.PII~ .>,i-ll C:rtlDollOI<S SilO~ IIJ TO!:>!: PilM\\~~S. !j,(F HTA" MUSOT liE ~u!ll.lmO TO llUS Ornc:t rOll I!C\I[W a:rrR: PROCl:d:IING IIITit 111~ fA~~C~llON ~ w a: fll !!.1 !!.1 c !!I co il: w 0 z 0 0 w 0 "( <( 1-N -0) -:::> . w c CJ)<( d wO F-> " -a: F-<(0 1-~~ <( (.) (§~ Ul .., 0 0 ,....0::: ill: m ~C) @.. DATE DRAWN 10/25/12 DRAWN BY JS JOB NUMBER 12-108 REVISED = PlANNING CORRECTIONS 2 = BUILDING CORRECTIONS 3 = HEAlTH DEPT. CORRECTIONS SHEET CONTENT HEALTH NOTES & PARKING ANALYSIS SHEET NUMBER T-1.5 • ROOM FINISH SCHEDULE All FINISHES SPECIFIED ARE FOR PERFORMANCE. EQUAL MANUFACTURES MAY FLOOR PLAN KEYNOTES BE PROVIDED W/ APPROVAL FROM CUENT AND JERSEY MIKE'S ROOM DESCRIPTION FLOOR ~ F 15:: ~ ~ F i"i ~------------------~0 ~ ~ X ROOM NAME ~ ~ BASE NEW GREASE TRAP. SEE P-1.0 (E) 2" WATER STUB UP TO BE RELOCATED. (E) ELECTRICAL PANELS TO BE RELOCATED. (N) WATER-UP LOCATION. SOV @ CLG. (N) WATER HEATER. SEE P-1.0 (N) LOCATION OF fLECTRICAL PANEL (N) LOCATION OF ENTRY SERVICE DOORS, (E) ENTRY SERVICE DOORS TO BE RELOCATED. (N) CLOSET DOOR ~(@D=oo~~W~A~S~H~/P~R=E~P~A~R=EA~---~-t-·f--r-T-t-·-r-r-t-·-r-r-t~r-t-•f--r-T-t-·-r-t-f--r~--t-·-r-r-r-·-r-·~-----------------1 1--(§)"'10~1-+-K_IT_CH_E_N_AR_E_A ____ --j-·-t--t-+-+--.+-1-l-·-+--t--+-+--t-·+--+-+-+--. +-+--+-+-+-+-.+--t-t ._ • WALL LEGEND @ WALK-IN COOLER e e e e e • @ SERVICE AREA e • • • • • • • @ CUSTOMER AREA e e • e e ~@)~oso:-J~B~A~R~A=R=EA'-'--------r-T-•f--r-T-t-•-r-r-t-•-r-r-t~f--·-T-•f--r-T-t-•-r-t-f--r•-r-r~-t-·-t-•-r-J L _____ ..J 1--EXISTING WAll TO REMAIN @) RESTROOM e e e e • e • e e !--"=''-+-------····-·· - -----l- f---r---------~-t-+--r-r-t~-t-+--r-r-t~r-t-+--r-r-t~-+--+~r-t-+--r-r-t~-lrl~7. v_v, >::.v·v_ »0'X':z.;;<'7· .v·n .. 1-NON-BEARING INTERIOR PARTITION SEEf3\ g r---l--------------------~--t-t-i--t-t-l--t-t-i--t-t-ll-t-t-i--t-t-l---t--t-ll-t-t-l--l-l-l~lti·~/~;/2'2/~/=.L/~/~/=.I);·j----MQAL STUD WW ~~ --.. _ --.... -~· --------t-1-+---+-+-f---l--+-+-1-t--t---l---SEE@ ----------ttii-l'----1-ttii-l-r-ttii-l-r-ti-r-ttii-l-l-ti~b~i!j&5~l/y/Q:t:t:~~ti§R..J..Jjii·r.y~vJfi:VJij;~0::~·~~\]);j-WALK-IN COOLER WALL SEE@ f--+----------+-+---+-+--+-+---t-f-t---+--r-- - - ---------·------- ---· -t---t-1 ~~f------------------r-r-r~~~+-+-+-+-+-~~~~~-+-+~-1-~--t---t---t--t--f-·- NOTE: @ ALL WALLS AND CEILINGS WILL BE SMOOTH, WASHABLE AND LIGHT COLORED 70% LRV. @ ALL FLOORS SHAll HAVE A SMOOTH , HARD NON-ABSORBENT SURFACE SUCH AS PORTLAND CEMENT, CERAMIC TILE, OR OTHER APPROVED MATERIAL THAT EXTENDS UPWARD ONTO THE WALLS AT LEAST 4" (1210.1) WALL SCHEDULE GENERAL NOTES NO. DESCRIPTION 1-7,..,--~-----------------------------------------t1. CONSIDERATION WILL NOT BE GRANTED FOR ANY ~)> EXISTING WALL TO REMAIN. ALLEGED MISUNDERSTANDINGS OF THE ftMOUNT OF .{. ,_ WORK TO BE PERFORMED. TENDER OF PROPOSAL 'f!y 3 5/B" X 20 GA. MTL. STUD NON-BEARING INTERIOR PARTITION WALL W/ 5/8" TYPE "X" GYP. BD. ON BOTH SIDES. SHALL CONVEY FULL AGREEMENT TO THE ITEMS AND <§13'> 3 5/B" X 25 GA. MTL. STUD LOW WALL W/ 5/8" TYPE "X" GYP. BD. ON EXPOSED SIDES (U.N.O.). CONDITIONS INDICATED ON THE DRAWINGS. SHOULD v THIE CONTRACTOR FIND DISCREPANCIES DR OMISSIONS I ~'li) WALK-IN COOLER WALL IN THE CONTRACT DOCUMENT OR BE IN DOUBT AS Tl) THE INTENT THEREOF, THE CONTRACTOR SHALL Ll ~ lt.J\ c m '"~~ EXISTING OBITAIN CLARIFICATION FROM THE DESIGNER AND/OR ( <§> BOUNDARY WALL TO REMAIN J · THE OWNER'S REPRESENTATIVE PRIOR TO SUBMmiNG HIS PROPOSAL FOR WORK. -z.rs: f--t----~"""=d..--~-----------------------------------12. G. C. SHALL FIELD VERIFY THE EXACT EXISTING DOOR SCHEDULE NO. DESCRIPTION I MFG. SIZE MATERIAL @) NEW SERVICE DOOR r-=--+--------+----· --·----.. @ RESTROOM 6' -o"x7' -o" 3' -O"x6' -8" SOLID CORE THK. THRES. 1 3/B" NO FINISH LITE PAINT HARDWARE PUSH PULL LOCK SET SELF CLOSER LEVER TYPE REMARKS PUSH-PUll SELF CLOSING ODOR SPACE CONDITIONS, DIMENSIONS AND COLUMN SPACING PRIOR TO CONSTRUCTION AND INFORM DESIGNER IMMEDIATELY IF ANY DISCREPANCIES ARE fD,UND BETWEEN DRAWINGS AND SITE CONDITIONS. ANY CHANGES OR REWORK DUE TO UNREPORTED DIFFERENCES SHALL BE AT G.C.'S EXPENSE HEALTH DEPT. NOTES f---+----------r----i-------jr--~---+----f------j-----+-----~1. ALL EQUIPMENT SHALL MEO NATIONAL SANITATION FOUNDATION DESIGN AND INSTALLATION REQUIREMENTS OR IT'S EQUiVALENT. 2. LIGHT FIXTURES IN FOOD PREPARATION, OPEN FOOD f--'-----------'-----.L_ ______ -..J'-----..J------'-------.L--------'----------'---------~ STORAGE AND UTENSIL WASHING .~REAS ARE TO BE STOREFRONT ELEVATION • 0 I a, IQ I }-. w----------·-- ' ' SCALE: 1/4"=1'-0" 20'-1" 19'-9" 'o I -... ~ v < < < < < < < < i < < < < ~ ~.A.~.A.~.A.~.A.~.A..A.A..A.A..A.A.~~~~.A~/ PROTECTED AGAINST BREAKAGE THROUGH THE USE OF PLASTIC SHIELDS, PLASTIC SLEEVES, SHADER PROOF BULBS AND/OR OTHER APPROVED DEVICES. 3. E)(fERIOR DOORS SHALL BE SELF-CLOSING AND FIT TO A MAXIMUM 1/ 4" AT THE BASE AND SIDES. 4. PROVIDE PERMANENTLY MOUNTED SINGLE SERVICE SOAP AND TOWEL DISPENSERS AT ALL HAND WASH BASINS. PROVIDE PERMANENTLY MOUNTED SIHGLE SERVICE SOAP AND TOWEL DISPENSERS AT ALL HAND WASH BASINS. 5. SEAL ALL CRACKS AND CREVICES IN COUNTERS, CABINETS, AROUND METAL FLASHING, SINK BACK SPLASHES AND AROUND PIPES AND CONDUITS WITII A NON-HARDENING SILICONE SEALANT. 6. QUARRY TILE TO BE "DAL-TILE" 7. ALL WALL & DRYWALL CEILING ARE TO BE PAINTED W/ SAME PAINT AS INDICATED ON THE FINISH SCHEDULE. B. ALL EXTERIOR WINDOWS, STOREFRONT ARE FIXED & NON OPERABLE. 9. ALL EXTERIOR DOORS ARE SELF-CLOSING & ( 10. NiJ"MixED DRINKS sERVED. 3 FIRE NOTES 1. PROVIDE PORTABLE FIRE EXTINGUISHER WITH A RATING OF 2A IOBC-ORY CHEM. FOR KITCHEN 2. PROVIDE FIRE EXTINGUISHER AS REQUIRED BY FIRE DEPT. FIELD INSPECTOR. 3. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 4. EXIT LIGHTING AND SIGNS: MINIMUM 6" X 3/4" LffiERS ON CONTRASTING BACKGROUND. 5. THIE INSTALLATION OR OPERATION OF SPECIAL FIRE EXTINGUISHER SYSTEM MUST BE CHECKED AND APPROVED BY THE FlRE DEPT. PRIOR TO INSTALLATION. 6. SEPARATE PLANS FOR ALL FIXED AND MOBILE FIRE PROTECTION EQUIPMENT, AND ALL FIRE ALARM SYSTEMS SHALL BE SUBMITIED TO THE FIRE MARSHALL FOR APPROVAL PRIOR TO INSTALLATION. 7. BUILDING OCCUPANT SHALL SECURE PERMITS REQUIRED BY THE FIRE DEPARTMENT FROM THE FIRE PREVENTION BUREAU PRIOR TO OCCUPYING THIS BUILDING. 28'-10" GC TO VERIFY 5'-8" / I I - ... . 1'"71 9'-2" l.l~.l ~l'D ~~~,.--_,~--Jv.>i"' __ -ct---+-R-'-~-, ... --.--'Q·-. ,_9 -~~-·-_ -_-----.l'i---~---_ ;c--" •• -,_1i ·,- ' V !~illlllllllll--1~ ',. '1<1 ! '-I !" ; '§ \.. ). ' ''.,!!.....!1,.-··--. :~·:,·"': ". 1-- HOOD ABOVE SEE MECH. ...-1 -... ·-· 6'::.g•----, -- @~ WASHING/ PREP AREA +·-"-1-_·_~1 I ·~').-·~~----_ ..&... • ~ I - -, . _v ;_:_ T __ ·':: . 1:.~.(::-_ :~·-' ·r;: ·. · 6'-6" 5'-0" • 0 J @v A 5'-o" WALKIN~ v1f.t;;=='=~~±-L--~~ C:OOLER 11~ __ · )'-6" II 5'-6" > @ SERVICE AREA ALL WAllS HAVE < A CURRENT R VALUE OF R-13. TYP. ~ ~ ./ s·-o· v v .". RODF ABOVE HAVE A CURRENT R VALUE OF R-22. TYP. : '--.. .A. .A t-' 2 i ; ; ... I 30'-10" . r.c.. m " £1. 13'-11" ,'~j)~ __-/e--1--~QI\)_~, ______......------\\\' ~ p., > OUTSIDE DINING AREA \ v ,Y is\ . l"lh,""J: ./.:.. ~-3 _, ---u:-iJ-· --<Yivl'> ' _,, . i • ..... . . v 4'-0" . ·I '· . I 5'-4" > FOR COMMON USE. APPROX. 470 SQ FT. ~ 2,_4, 3._6• 3•_6• ' 3•_0• \.... ~ ~ > > > > > > 19'-4" • ~-~~ • 'T "' • '"' I ;.., • "i' ~ \ J FLOOR PLAN SCALE: 1/4"=1'-0" N CD ffi lltEl!E DMMiiS ..., S!'f:CI~CI.~~ A~P ICI!C~ "ESICW:S o.~<n I.JI~IliGilltl!lS RU'IIESEII'Ial 'Hl\rliY All~ IJID SHill !tWAIN llit: Pri~Pll'o' Of ~AAY 11y;c; f. Mi>O~~'llS; .'II~ 110 P'-f<f Til~ SHO.U. BE COPI£!), 0.5a.OSOl TO Ol!lEIIS OR Ustll IN C~H!CTI~ \.m-1 ANY 1100~ 011 r~MCT ClhEII Til/oil iliE S"ECIFJ:: fRO.ECT fill; MtJCH llir'l' ~liVE D::a.l fRUARm '-'Ill DDIE..OPfD Wlhlllll lHf YlftU'lEII COiiSOil IX foi.Rr ll'l<lolti 3< ~SSOC~'JES Vl~AI-COiilACl 111111 lltrst CI/I\111UC>S mJ OP.OFlC~lllllli> S.1m C~ST\1\11'1: COOCI.U!iM: ~~IDU<t:E OF TUCSC ftCSlm::JIOOS. \llll'lltH tiiiCH~ON~ OH T\ICst UA'IIINOS ;ttO.U. H~Vl: f~fCE:lf!il:i: 0'/DI SI:MfC w.:IISI-l15. COI!ll\AC101'5 ~·iAI.I-~n. AN) E'!E: I<Uof'LtiS.s..l: rllli '1.-l-OIIIW\olllNS ~I·P tc::t-IOITIC:ViS ON '00 JOB AMD TillS omcr Wn I.E NOllflW 01" ANY VMIAT\ONS mOM lllE O.M:~SIOJtS o\NO CtlNiliTilt<S :,.tO\Oij or "fjESE o~·..,.~tos. 5IIOP Pni.IL loiJ5T liE "'~'"mr ro THIS atT.cc ro~ ~w SEfQJIC I'RoctwmQ \lint ll·t F.>.BftiCilliCK !/.!\ !12\ l/3\ !/.\ !/~ 1/~\ 3: w a: Cl c z <( c a: <( 0 Cl wro 0 wo i-N (j) :) . (/)<( wO > . <(0 ~[Jj (3~ ..-0:::: ~<3 DATE DRAWN 10/25/12 DRAWN BY JS JOB NUMBER 12-108 REVISED : PlANNING CORRECTIONS : BU!LDJNG CORRECTIONS : HEALTH DEPl CORRECTIONS - - - SHEET CONTENT FLOOR PLAN & ROOM FINISH SCHEDULE SHEET NUMBER A-1 .0