Loading...
HomeMy WebLinkAboutCDP 98-36; Rowan Residence; Coastal Development Permit (CDP)crry-OF CARLSBAD REVIEW AND CEMENT MFMO DATE TO JUNE H. 1998 REVISED PLAN ENGINEERING DEPARTMENT *POLICE DEPARTMENT - J. SASWAY •FIRE DEPARTMENT - MIKE SMITH -BUILDING DEPARTMENT - PAT KELLEY A 'COMMUNITY SERVICES - MARK STEYA •COMMUNITY SERVICES - VIRGINIA McC * WATER LANDSCAPE PLANCHECK CONSULTANT - SCHOOL D1ST •NORTH COUNTY TRANSIT DISTRICT - Planning Department SAN DIEGO GAS AND ELECTRIC - BICH TRAN (Memo Only) -ALWAYS SENT EXHIBITS FROM Planning Department REQUEST FOR REVIEW AND COMMENT ON APPLICATION NO NOTE Please use this number on all correspondence. CDP 98-36 V PROJECT TITLE: APPLICANT: PROPOSAL: ROWAN RESIDENCE RALPH ROWAN SINGLE FAMILY RESIDENCE Please review and submit written comments and/or conditions to: GREG FISHER the Project Planner in the Planning Department. 2075 Las Palmas Drive, by JUNE 18. 1998 . If not received by that date, it will be assumed that you have no comment and the proposal has your endorsement as submitted If you have any questions, please contact C. FISHER at 438-1161. extension U328 THANK YOU COMMENTS 1X2 'I AN:, ATTACHED FRM0020 5/94 Memorandum TO: Planning Technician, Greg Fisher FROM: Engineering Technician, David Rick DATE: September 22, 1998 CDP 98-36: Rowan Residence COMPLETENESS & ISSUES REVIEW Engineering Department staff has completed a review of the above-referenced project for application completeness. The application and plans submitted for this proposed project are considered complete. Additionally, staff has conducted a review of the project for engineering issues of concern. Engineering issues which need to be resolved or adequately addressed prior to staff making a determination on the proposed project are as follows: A 4. The swale which extends along each side of the house must be located one foot from the property line and 5 feet from the building foundation. Please revise plans to indicate these distances on the plan. Show correct direction of grade on driveway. The lot slopes down eastward yet the driveway slopes down westward. Please revise plan to show the driveway's correct grade. The front property line is located 23 feet from the street center line, not 20 feet. Please revise plans accordingly. Until recently, the City did not permit concentrated drainage (i.e. underground drains, drainage ditches, etc.) to flow onto any underlying properties. All drainage had to sheet- flow to the underlying property. Many property owners were informed of this restriction and have designed their lots to drain accordingly. Do to issues which have surfaced regarding this restricted design, City staff is now permitting underground drains to be installed across the underlying property provided that the necessary easements for such cross drainage are obtained from the underlying property owner. Although the proposed "sheet flow" design is still acceptable, you may redesign your drainage with the use of an underground drain. If you choose to redesign accordingly, Condition No. 3 written below will apply. Once the aforementioned issues are adequately addressed the following conditions of approval shall be incorporated into the adopting resolution: 1. The developer shall pay all current fees and deposits required. 2. The owner of the subject property shall execute an agreement holding the City harmless regarding drainage across the adjacent property. 3. The owner^shall record a deed restriction on the property which relates to the proposed cross lot drainltgsshown on the site plan. The deed restriction document shall be in a form acceptable to the City^ngineer and shall: A. clearly delineate the limits of the drainage course; \.NB. state that the drainage course is to be maintained in perpetuity by the underlying property owhec and C. state that all future use of the property along the drainage course will not restrict, impede, divert or otherwise after drainage flows in a manner that will result in damage to the underiying^qnd adjacent properties or the creation of a public nuisance. If you or the applicant have any questions, please either see or contact me at extension 4324. DAVID RICK Engineering Technician Land Development Division