HomeMy WebLinkAboutCP 93-05; Cove Condominiums Stipe Conversion; Condo Permit (CP) (12)City of Carlsbad
Engineering Department
July 27, 1993
James F. Gillen,
Williamson and Schmid
15101 Red Hill Avenue
Tustin, CA 92680
MS 93-08, COVE PARK STIPE CONDO CONVERSION
Thank you for your application for a tentative parcel map, Minor Subdivision. The application
is incomplete and unsuitable for further review. The items needed to make the application
complete are as follows:
1. A signed and notarized Agreement to Pay a Public Facilities Fee was not submitted. Two
agreements and instructions for completing the agreement are enclosed and these items
are also enclosed in the letters to the listed owners. Please note that all owners as shown
on a complete title report must sign the agreement. The tentative map shows the
ownership to be in two parts:
I. "Unit" 1 held by McCain, address 1324 Laurelwood Court Dallas, OR 97338
II. "Unit" 2 held by Mullin, address 4549 Cove Dr. Carlsbad, CA 92008
The tax assessor's roll shows McCain's address to be 6498 Crampton Drive, No., Keizer,
Oregon. Please advise us which address is correct.
Due to the physical separation of the ownership parties the City will accept two separate
agreements, signed and notarized by each separate owner.
2. Postage for the two required notice mailings was not submitted. Our policy is to accept
a 500 dollar deposit or the actual postage required. We find that after eliminating
duplicates that there are 85 property owners to notify and two notices each are required.
At 29 cents each the actual postage required is .29 cents times two times 85 or $49.30
required postage. Your application cannot be found complete until this amount, $49.30,
is received.
H-\T.TRBARY\ENn\WIT)ATA\PAVlS\MS<>S-ar!V.STP
2O75 Las Palmas Dr. • Carlsbad, CA 92OO9-1576 • (619) 438-1161 • FAX (619) 438-O894
James F. Gillen
MS 93-08, Cove Park Stipe Condo Conversion
July 27, 1993 Page: 2
3. A complete tide report showing all the holders of interest, that is the owners of both
"units". This title report is required in order to process the Agreement to Pay a Public
Facilities Fee.
4. The tentative map must show the following data:
• the density in dwelling units per acre
• the existing General Plan designation (RH)
• iot area and unit/lot area for each unit/lot
' '• total building coverage (separately for each unit/lot)
• traffic generation, 16 ADT (eight per dwelling unit)
• show which of the three gas and water meters and the two electric meters serve
which unit. See also issue 4, below. Alternatively you may submit letters from
S.D.& G. and the Carlsbad Municipal Water District stating that satisfactory
services for two units has been arranged or can be arranged.
• correct unit/lot division lines and dimensions (see issue 1, below)
• vegetation (plans show an area marked "Landscape", but no details).
In addition to the incomplete items, above, there are some issues with the project as presented.
These issues must be resolved before any approval the tentative map and condominium permit
can be recommended. These issues are as follows:
1. The structure on site appears to have a three-car garage. The condominium plan and
tentative map shows a residential building line passing straight through the middle
garage, and die condominium plan shows only two garage spaces, each 16 feet wide by
21.75 feet in length. Minimum two-car garage in«fid^ dimensions are 20 feet by 20 feet.
See also 2, below.
2. The applicant must provide sufficient information on die plans to demonstrate diat die
proposed conversion satisfies die requirements of die Planned Development regulations,
Chapter 21.45 of die Carlsbad Municipal Code. The current submittal does not
demonstrate such compliance, for example:
H:\IJBRAaY\ENO\WPDATA\DA VIS\MS93-»CV.STP
James F. Gillen
MS 93-08, Cove Park Stipe Condo Conversion
July 27, 1993 Page: 3
Section 21.45.090 (c) of the Carlsbad Municipal Code requires all dwelling units to have
two covered parking spaces. A total four is required for two units. As per 1, above there
appears to be three spaces and insufficient room for four.
See the enclosed Chapter 21.45 of the Code for all the requirements.
3. The R-W Zone allows a maximum structure height of 35 feet. The plans submitted do
not include elevations,therefore it is not clear whether the existing structure is within this
limit.
4. Prior to approving a final map, or a Certificate of Compliance in lieu of a final map, the
applicant must provide evidence that the structure to be converted meets present City
building regulations per Section 21.45.100 (a) of the Carlsbad Municipal Code. A
compliance inspection by the City of Carlsbad Building Department will need to be made
and the structure and two dwelling units will need to be found in compliance with all
building regulations for two condominium units.
Since there are three gas and water meters and three single-car garage doors, the proposal
to subdivide into two condominium units may not, at this time, comply with all
regulations.
Enclosed for information only is a copy of a letter from Lindsay Management Services,
representing the Bristol Cove Property Owners Association.
If you need more information on this letter please contact me at (619) 438-1161, extension 4500.
JIM DAVIS
Associate Engineer
Enclosures (4)
c: Assistant City Engineer
Principal Civil Engineer, LUR
Project Planner, Elaine Blackburn
Richard and Debra Mullin, enclosures (3)
James and Bonnie McCain, enclosures (3)
Steven G. Stipe Construction, enclosures (4)
Landsey Management Services
H:\UBRARY\ENG\WPDATA\DAVIS\MS93-8CV.STP