Loading...
HomeMy WebLinkAboutCP 99-07; Chestnut Condos; Condo Permit (CP) (2)\ city of May 4, 1999 Barry Blue 2231 La Mirada Vista, CA 92083 SUBJECT: CP 99-07KDP 99-l 6 - 140 - Chestnut Condos Thank you for applying for Land Use Permits in the City of Cartsbad. The Planning Department has reviewed your Condominium Permit and Coastal Development Permit, application no. CP 99-07 & AV 99-16, as to its completeness for processing. The application is incomplete, as submitted. Attached are two lists. The first list is information which must be submitted to complete your application. This list of items must be submitted directly to your staff planner by appointment. All list items must be submitted simultaneously and a copy of this list must be included with your submittals. No processing of your application can occur until the application is determined to be complete. The second list is issues of concern to staff. When all required materials are submitted the City has 30 days to make a determination of completeness. If the application is determined to be complete, processing for a decision on the application will be initiated. In addition, please note that you have six months from the date the application was initially filed, April 5, 1999, to either resubmit the application or submit the required information. Failure to resubmit the application or to submit the materials necessary to determine your application complete shall be deemed to constitute withdrawal of the application. If an application is withdrawn or deemed withdrawn, a new application must be submitted. Please contact your staff planner, Greg Fisher, at (760) 438-l 161, extension 4328, if you have any questions or wish to set up a meeting to discuss the application. Sincerely, Planning Director MJH:GF:mh c: Gary Wayne Chris DeCerbo David Rick Bobbie Hoder File Copy Data Entry Planning Aide 2075 La Palmas Dr. - Carlsbad, CA 92009-l 576 - (760) 438-l 161 - FAX (760) 438-0894 LIST OF ITEMS NEEDED TO COMPLETE THE APPLICATION Nos. CP 99-07KDP 99-16 Planning: 1. The subject site is located within the Beach Area Overlay Zone. The proposed two unit condominium project requires the processing and approval of a Site Development Plan (SDP). The fee for the SDP is $2,670.00 and was omitted from the original application submittal on April 5, 1999. The Planning Department will deem your application complete as soon as the check for the SDP is received. For your convenience, you may either bring the check in person or mail the check to the City of Carlsbad. Be sure to reference the project by name or application number when mailing the check. NOTE: There is no other information required for the SDP other then the fee. Engineering: Refer to separate engineering letter. ISSUES OF CONCERN Planning: 1. The common (“BBQ”) area must meet the required 200 square feet minimum per the Planned Development Ordinance 21.45.090. This common area shown on the site plan appears to be less then 200 square feet, please clarify and dimension. Engineering: Refer to separate engineering letter. Date: Mav 10. 1999 Planning Department City of Carlsbad 2075 Las Palmas Drive Carlsbad, California 92009 TO: Grea Fisher FROM: Kellv Efimoff CMWD NO. 99-C.523 SUBJECT: Chestnut Condominiums CDP 99-16/CP 99-7 The District is providing comments on the subject project dated March 31, 1999. Based on our review of the documents submitted, we have the following comments regarding potable water, recycled water and sewer systems: 1. The Developer will be expected to provide detailed information to the District Engineer regarding water demand, irrigation demand, fire flow demand in gallons per minute, and projected sewer flow in million gallons per day. 2. The entire potable water system, recycled water system and sewer system shall be evaluated in detail by Developer and District Engineer to insure that adequate capacity, pressure and flow demands can be met. 3. All District pipelines, pump stations, pressure reducing stations and appurtenances required for this project by the District shall be within public right- of-way or within easements granted to the District or the City of Carlsbad. Page 2 -- -- Planning Department Date: May 10, 1999 4. Sequentially, the Developer’s Engineer shall do the following: 5. 6. 7. A. Meet with the City Fire Marshal and establish the fire protection requirements. B. Prepare and submit a colored recycled water use area map and submit this map to the Planning Department for processing and approval by the District Engineer. C. Prior to the preparation of sewer, water and recycled water improvement plans, the Developer shall submit preliminary system layouts to the District Engineer for review, comment and approval. All potable water and recycled water meters shall be placed within public right of way. No more than 19 homes (dwelling units) shall be served on a single potable water distribution pipeline. For those locations with more than 19 homes (dwelling units), a looped potable water pipeline system shall be designed. The Developer should verify with the District Engineer that a looped system will not be required for this project. If fire hydrant(s) are required by the Fire Marshal, a looped fire line system may be required for any fire line run greater than 150 feet. The Developer shall verify with the District that a looped fire line system will not be required for this project. If you have any questions, please contact the undersigned. Kelly Efimoff Associate Engineer cc: David Rick, Engineering KJE: kje