Loading...
HomeMy WebLinkAboutCT 06-27; Muroya Subdivision; Tentative Map (CT)~(~'t~ ~ CITY OF CARLSBAD LAND USE REVIEW APPLICATION P-1 Development Services Planning Department 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov APPLICATIONS APPLIED FOR: (CHECK BOXES) Development Permits 0 Administrative Permit (FOR DEPT. USE ONLY) Legislative Permits (FOR DEPT. USE ONLY) 0 Coastal Development Permit (*) OMinor 0 Conditional Use Permit(*) 0 Minor 0 Extension 0 Environmental Impact Assessment 0 Habitat Management Permit 0 Minor 0 Hillside Development Permit (*) 0 Planned Development Permit (!) Residential 0 Non-Residential 0 Planned Industrial Permit 0 Planning Commission Determination 0 Site Development Plan 0 Special Use Permit 0 Tentative Tract Map 0 Variance 0Administrative 0 General Plan Amendment 0 Local Coastal Program Amendment (*) D Master Plan 0 Specific Plan 0 Zone Change (*) 0Amendment [l]Amendment D Zone Code Amendment List other applications not specified 0 Condominium Permit D D (*) = eligible for 25% discount NOTE: A PROPOSED PROJECT REQUIRING MULTIPLE APPLICATIONS BE FILED, MUST BE SUBMITTED PRIOR TO 3:30P.M. A PROPOSED PROJECT REQUIRING ONLY ONE APPLICATION BE FILED MUST BE SUBMITTED PRIOR TO 4:00P.M. ASSESSOR PARCEL NO(S).: 215-040-03 ---------------------------------------------------------------------PROJECT NAME: Muroya Residential Subdivision BRIEF DESCRIPTION OF PROJECT: Residential subdivision of 2 residential lots, 1 Private StreeUDriveway Lot and OS lot for the construction of 37 detached condominiums units on 20.3 acres OWNER NAME (Print): Muroya Family Trust 05-18-98 MAILING ADDRESS: PO Box 131016 CITY, STATE, ZIP: ...:C..;;.a.;.;.rls.;.;.b;..;.a:..:.;d.:...., C.:..:A...:_ ____ __:9..:::2...;..01.;_3;....___ TELEPHONE: 858-864-6206 -----------------------------EMAIL ADDRESS: I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY E. APPLICANT NAME (Print): Taylor Morrison of CA, LLC MAILING ADDRESS: 15 Cushing -----------------------------; CITY, STATE, ZIP: ..:..:lrv...;;.i..:..:n...;..e,:....C;;.;;A....;...;;..92;;;;..6;;....1...:8 ________ --I TELEPHONE: 858-864-6206 ------------------------------~ EMAIL ADDRESS: atornillo@taylormorrison.com P-1 Page 1 of 5 Revised 04/09 BRIEF LEGAL DESCRIPTION: The East one-half of the Northeast quarter of the Northwest quarter, Section 27, Township 12 South, Range 4 West, San Bernardino Base and Meridian, in the City of Carlsbad. LOCATION OF PROJECT: Not Assigned Yet ----~------------------S~T=R~E~ET~AD~D~R~E~S~S------------------------ ON THE: West SIDE OF Black Rail Road (NORTH, SOUTH, EAST, WEST) (NAME OF STREET) BElWEEN Corte Orchidia AND Avena Ct (NAME OF STREET) (NAME OF STREET) IN THE PROCESS OF REVIEWING THIS APPLICATION IT MAY BE NECESSARY FOR MEMBERS OF CITY STAFF, PLANNING COMMISSIONERS, DESIGN REVIEW BOARD MEMBERS OR CITY COUNCIL MEMBERS TO INSPECT AND ENTER THE PROPERTY THAT IS THE SUBJECT OF THIS APPLICATION. 1/WE CONSENT TO ENTRY FOR THIS PURPOSE. NOTICE OF RESTRICTION: PROPERTY OWNER ACKNOWLEDGES AND CONSENTS TO A NOTICE OF RESTRICTION BEING RECORDED ON THE TITLE TO HIS PROPERTY IF CONDITIONED FOR THE APPLICANT. NOTICE OF RESTRICTIONS RUN WITH THE LAND AND BIND ANY SORS IN INTEREST. =- FOR CITY USE ONLY P-1 RECEIVED NOV 1 0 2009 CITY OF CARLSBAD PLANNING DEPT Page 2 of5 RECEIVIO ',,, 1 0 2009 CiTY OF CARLSBAD i..ANNING DEPT DATE STAMP APPLICATION RECEIVED RECEIVED BY: Revised 04/09 e . • ·_ Cit}' of Carlsbad I#IL'·"""·'•*4·L''"·'4"' DISCLOSURE STATEMENT Applicant's statement or disclosure of certain ownership interests on all applications which will require discretionary action on the part of the City Council or any appointed Board, Commission or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print. Note: Person is defined as "Any individual, firm, co-partnership, joint venture, association, social club, fraternal organization, corporation, estate, trust, receiver, syndicate, in this and any other county, city and county, city municipality, district or other political subdivision or any other group or combination acting as a unit." Agents may sign this document; however, the legal name and entity of the applicant and property owner must be provided below. 1. 2. APPLICANT (Not the applicant's agent) Provide the COMPLETE. LEGAL names and addresses of ALL persons having a financial interest in the application. If the applicant includes a corporation or partnership, include the names, title, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON- APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation. include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person ~(I"\ Title. __ -=-:~M ....... A---=-------- Address ~(~ Corp/Part._..,....-tJI_t=\ ______ _ Title __ --:~...;_( A ______ _ Address___,l'-=---l._[,Pc;. ______ _ OWNER (Not the owner's agent) Provide the COMPLETE. LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (i.e., partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, title, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation. include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Perso;-W.t;, 'kiP d.o/4 Corp/Part. ________ _ Title 7l<UsTEE --OWNOZ Title. _________ _ 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us <i) 3. NON-PROFIT ORGANIZATION OR TRUST If any person identified pursuant to (1) or (2) above is a nonprofit organization or a trust, list the names and addresses of ANY person serving as an officer or director of the non-profit organization or as trustee or beneficiary of the. Non Profitrrrust Non Profitrrrust ________ _ Title Title. ____________ _ Address. ________ _ Address __________ _ 4. Have you had more than $500 worth of business transacted with any member of City staff, Boards, Commissions, Committees and/or Council within the past twelve (12) months? 181 Yes D No If yes, please indicate person(s): (J l.lll"'cr '.l 6vsr--~s.t_, ~ "', o 1t~t. t;f'oVI~-s, oLa.. s-s; •"'4( l7 -* 1/ s wk.-le.s.<4./-c pt:~t.lw.. tr~J f.J c; t.:~'1 d t c.., tJ , .. ~. NOTE: Attach additional sheets if necessary. Prinf or type mime of owner 7 Print or type name of applicant Signature of owner/applicant's agent if applicable/date Print or type name of owner/applicant's agent 2 of2 CITY OF CARLSBAD LAND USE REVIEW APPLICATION 1) APPLICATIONS APPLIED FOR: (CHECK BOXES) (FOR (FOR DEPARTMENT DEPARTMENT USE ONLY) USE ONLY) 0 Administrative Permit D Planned Industrial Permit 0 Administrative Variance D Planning Commission Determination C8j Coastal Development Permit L:D?Ob-3 {] Precise Development Plan 0 Conditional Use Permit D Redevelopment Permit [g] Condominium Permit cp o& -('i D Site Development Plan m1 Environmental Impact Assessment D Special Use Permit C8J General Plan Amendment S Mol.:-~6 'B Specific Plan ~ Hillside Development Permit Itt DP C*"-lC +eAtati>Je F!aFsel Maf} )' Obtain from Engineering Department [g] Local Coastal Program Amendment L. r'Pt\-0~ -Cf 1~ Tentative Tract Map ~~c&-2:7 0 Master Plan D Variance 0 Minor Conditional Use Permit [g) Zone Change c.~O~-D 0 Non-Residential Planned Development ~ tf;;. fca67o~s;c;_ 0 Planned Development Permit 2) ASSESSOR~RCELNO(S).: ~21~~~M~~~m~~~~~~~~~~~~~~~~~~~~~~ 3) PROJECT NAME: ___;..;M..:..:u=ro:....r..y=-a ~Re=s..:..:id=en=ti=ai;....:S=u=bd=iv.;...;.is=io=n;....__ ______________ _ 4) BRIEF DESCRIPTION OF PROJECT: Residential s11bdivision of 2 residential lots 1 Private Street/Driveway I at and 2 OS lots for the construction of 37 detached condominiums units on 20 3 acres A d S lsb d ~pplicant Representative: Jack Hent wm & Associates, 5365 Aveni a Encinas, 'uite A, Car a, CA 92008 5) OWNER NAME (Print or Type) 6) APPLICANT NAME (Print or Type) Muroya Family Trust 05-18-98 Taylor Woodrow Homes, Inc MAILING ADDRESS MAILING ADDRESS PO Box 131016 167 45 W. Bernardo Dr., Ste 140 CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHONE Carlsbad, CA 92013 (858) 943-5100 San Diego, CA 92127 (858) 943-5100 EMAIL ADDRESS: EMAIL ADDRESS: I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE I CERTIFY THAT I AM THE LEGAL REPRESENTATIVE OF THE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY OWNE;e~ND THAT ALL THE ABOVE INFORMATION IS TRUE AND KNOWLEDGE. CORR ·~MYKNOWLEDGE. ~.U'Jw.f&<.:J4 · ~ /.z -6--,yuC, IJ tthlrf- SIGNATURE ' ATE SIG~RE DA--~ 7) BRIEF LEGAL DESCRIPTION Fast 1/? of the NF O!Jarter of the NW O!!arter Sec 27 Township 12S Bange 4W San Bernardino Base and Meridian City of Carlsbad Co11nty of San Diego NOTE: A PROPOSED PROJECT REQUIRING MULTIPLE APPLICATIONS BE FILED, MUST BE SUBMITTED PRIOR TO 3:30 P.M. A PROPOSED PROJECT REQUIRING ONLY ONE APPLICATION BE FILED, MUST BE SUBMITTED PRIOR TO 4:00 P.M. Form 14 Rev. 03/06 • c 0 ' 8) LOCATION OF PROJECT: . ~~ _____ No_n_e_a_ss_ig_n_ed_y_e_t. ____ ~~~~~------------------~ 9) 10) 13) 16) 19) 22) 25) ONTHE~I --~~W~e~st~~~~~ (NORTH, SOUTH, EAST, WEST) BEnNEEN~~---=C~or=te~O~rc=hi=di=a=---~ (NAME OF STREET) LOCAL FACILITIES MANAGEMENT ZONE 20 STREET ADDRESS Sl DE oFI ~ -------::-B.,...,.Ia.,....,c=""k =Ra,...,i I=R=o=ad,.....-__ __. (NAME OF STREET) AND~~----~~A~ve~na=C=t~----~ (NAME OF STREET) PROPOSED NUMBER OF LOTS 011) NUMBER OF EXISTING 012) PROPOSED NUMBER 0 OF RESIDENTIAL UNITS 38 RESIDENTIAL UNITS TYPE OF SUBDIVISION ~14) PROPOSED IND OFFICE/~ 15) PROPOSED COMM ~ SQUARE FOOTAGE SQUARE FOOTAGE PERCENTAGE OF PROPOSED I Approx 117) PROPOSED INCREASE ~18) PROPOSED SEWER 0 PROJECT IN OPEN SPACE INADT USAGE IN EDU GROSS SITE ACREAGE ~20) EXISTING GENERAL ~21) PROPOSED GENERAL B PLAN PLAN DESIGNATION EXISTING ZONING 023) PROPOSED ZONING I RO-M 124) HABITAT IMPACTS ~ IF YES, ASSIGN HMP # IN THE PROCESS OF REVIEWING THIS APPLICATION IT MAY BE NECESSARY FOR MEMBERS OF CITY STAFF, PLANNING COMMISSIONERS, DESIGN REVIEW BOARD MEMBERS OR CITY COUNCIL MEMBERS TO INSPECT AND ENTER THE PROPERTY THAT IS THE SUBJECT OF THIS APPLICATION. 1/WE CONSENT TO NTRY FOR THIS PURPOSE FOR CITY USE ONLY FEE COMPUTATION APPLICATION TYPE FEE REQUIRED TOTAL FEE REQUIRED Form 14 Rev. 03/06 DEC f ~ 2006 CITY OF CARLSBAD DATE~~~~~lRECEIVED I '/L PAGE 2 OF 5 c CITY OF CARLSBAD APPLICATION REQUIREMENTS FOR: COASTAL DEVELOPMENT PERMIT (SINGLE FAMILY REGULAR AND MINOR) COASTAL DEVELOPMENT PERMIT SUPPLEMENTAL APPLICATION (FOR ALL COASTAL DEVELOPMENT PERMITS) This supplemental application is to be filed for any development requiring a Coastal Development Permit issued by the City of Carlsbad. **Application checklist for Non-Single Family Regular Coastal Development Permits covered under separate handout. A proposed project requiring that multiple applications be filed must be submitted prior to 3:30 p.m. A proposed project requiring that only one application be filed must be submitted prior to 4:00 p.m. All joint application exhibits, i.e. Tentative Map and Planned Development Site Plan should be prepared at the same scale. (Use a scale no smaller than 1" = 40'.) This supplemental application is to be filed for any development requiring a Coastal Development Permit issued by the City of Carlsbad. I. GENERAL BACKGROUND A. Estimated Cost of Development: Development costing $60,000 or more does not qualify as a Minor Coastal Development Permit. The Planning Director shall make the final determination regarding a project's cost of development. The primary basis for determining cost of development will be the application of dollar costs per square foot for different types of residential construction. These costs are set by the International Conference of Building Officials (ICBO) and are applied throughout San Diego County. Please complete the following information to assist in the determination of this project's cost of development (Contractor proposals may also be submitted for consideration by the Planning Director). Please refer to the current fee schedule for the appropriate $/square foot fee rate. New Residential Square Footage: 1 02 677 square feet x $ 1 02 /sq. ft.= $ __ ____.1-"'0·..:L47'-"'3""'0""54L.._ __ _ Residential Addition Square Footage: ______ square feet x $ /sq. ft.=$ __________ _ Any Garage Square Footage: ______ square feet x $ /sq. ft. = $ __________ _ Residential Conversion Square Footage: ______ square feet x $ /sq. ft.=$ __________ _ Please contact the City of Carlsbad Building Department for current fee rate for Non- Residential uses (i.e. RetaiVStore; Restaurants; Office; and Manufacturing/Ware house uses.) ______ square feet x $ __ /sq. ft.=$ ___________ _ COST OF DEVELOPMENT ESTIMATE: $ ______ 1.:..::0.J...:.4.:....:73=,0=54-'------- • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 13 Revised 04/04 Page I of7 ·. c B. Do you wish to apply for: 1. A Minor Coastal Development Permit (Under $60,000 cost estimate) D 2. A Regular Coastal Development Permit ($60,000 or more cost estimate) IXJ C. Street address of proposed development None Assigned Yet D. Assessor's Parcel Number of proposed development 215-040-03 E. Development Description: Briefly describe project: 37 detached condominium project on a 20.27 acre site within Local Facilities Management Zone 20. Applications include a tentative map, condominium permit, coastal development permit, hillside development permit, general plan amendment, zone change and local coastal program amendment. F. Describe the present land uses (i.e. vacant land, single family homes, apartments, offices, etc.) that surround the proposed development to the: G. North: Existing Single Family Homes South: Existing Condominiums East: Existing Single Family Homes and Vacant Land West: Existing Single Family Homes Is project located within a 100-year flood plain? [!] No II. PRESENT USE OF PROPERTY III. A. Are there existing structures on the property? [!]Yes D No If yes, please describe. B. Existing single family residence within the southeastern portion of the site that will remain and existing shade houses/maintenance sheds. Will any existing structure be removed/demolished? [!]Yes D No If yes to either question, describe the extent of the demolition or removal, including the relocation site, if applicable (also show on plans). The shade houses and maintenance sheds will be demolished and removed as part of the proposed project. LOT COVERAGE A. Existing and Proposed Existing New ProQosed Total Building Coverage 4,800 sq. ft. 65,005 sq. ft. 69,805 sq. ft. Landscaped Area 344,125 sq. ft. 191,416 sq. ft. 191,416 sq. ft. Hardscape Area 34,685 sq. ft. 72,597 sq. ft. 107,282 sq. ft. Unimproved Area (Left Natural) 490,487 sq. ft. 484,887 sq. ft. 484,887 sq. ft. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 13 Revised 04/04 Page 2 of7 ' .. c B. Parking: Number of existing spaces 2 Number of new spaces proposed 91 Existing/Proposed TOTAL: 93 Number of total spaces required 86 Number of covered spaces 74 Number of uncovered spaces 17 Number of standard spaces 17 Number of compact spaces 0 Is tandem parking existing? DYes#_ [!]No Is tandem parking proposed? DYes#_ [!]No C. Grade Alteration: Is any grading proposed? [!]Yes DNo Ifyes, please complete the following: 1. Amount of cut 23,350 cu. yds. 2. Amountoffill 20,100 cu. yds. 3. Maximum height of fill slope 20 feet 4. Maximum height of cut slope 16 feet 5. Amount of import or export 0 cu. yds. 6. Location of borrow or disposal site N/A • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Form 13 Revised 04/04 Page 3 of7 0 PROJECT DESCRIPTION/EXPLANATION PROJECT NAME: ____ ...,o.M=u=r=o..l-'ya=P"-'r=o.&:-pe=rty~------------ APPLICANT NAME: ---~T.:::.avl..!.lo;:;;.:r;_W~o:::..;od=r=ow..:...:.....:;H=o=m=e=s"-', I=n=c _______ _ Please describe fully the proposed project by application type. Include any details necessary to adequately explain the scope and/or operation of the proposed project. You may also include any background information and supporting statements regarding the reasons for, or appropriateness of, the application. Use an addendum sheet if necessary. Description/Explanation: Taylor Woodrow Homes, Inc is requesting the approval of a tentative tract map, condominium permit, coastal development permit, hillside development permit, general plan amendment, zone change and local coastal program amendment for a proposed detached condominium development located within Local Facilities Management Zone 20 on the west side of Black Rail Road (APN 215~040~03). The proposed project will consist of 3 7 detached condominium units. The proposed homes will consist of four (4) floor plans ranging in size from approximately 2,068 to 2,827 square feet. Plan 1 -Approximately 2,228 sq. ft. Elevation Styles -Adobe Ranch Andalusian Plan 2-Approximately 2,068 sq. ft. Elevation Styles-Adobe Ranch Andalusian Santa Barbara Plan 3 -Approximately 2,495 sq. ft. Elevation Styles -Adobe Ranch Andalusian Santa Barbara Plan 4-Approximately 2,827 sq. ft. Elevation Styles -Andalusian Santa Barbara City of Carlsbad M$@illliill.i•M•Siiill@lll DISCLOSURE STATEMENT !Applicant's statement or disclosure of certain ownership interests on all applications which will require discretionary action on the part of the City Council or any appointed Board, Commission or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print. Note: Person is defined as "Any individual, firm, co-partnership, joint venture, assoc1atwn, social club, fraternal organization, corporation, estate, trust, receiver, syndicate, in this and an other county, city and county, city municipality, district or other political subdivision or any other group or combination acting as a unit." Agents may sign this document; however, the legal name and entity of the applicant and property owner must be provided below. 1. APPLICANT (Not the applicant's agent) Provide the COMPLETE, LEGAL names and addresses of ALL persons having a financial interest in the application. If the applicant includes a corporation or partnership, include the names, title, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON- APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person Taylor Woodrow Homes. Inc Corp/Part Title------------- Address 167 45 W. Bernardo Drive. Ste 140 San Diego, CA 92127 2. OWNER (Not the owner's agent) Title--------------- Address-------------- Provide the COMPLETE, LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (i.e, partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly- owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person Muroya Family Trust 05-18-98 Corp/Part Title------------- Address PO Box 131 016 Carlsbad. CA 92013 Title---------------- Address -------------- 1635 Faraday Dr. • Car1sbad, CA 92009-1576 • (760) 602-4600 • FAX (760) 602-8559 • www.cl.carlsbad.ca.us 3. NON-PROFIT ORGANIZATION OR TRUST If any person identified pursuant to (1) or (2) above is a non12rofit organization or a trust, list the names and addresses of ANY person serving as an officer or director of the non-profit organization or as a trustee or beneficiary of the. Non Profit/Trust Akira Muroya Title Trustee Address PO Box 131016. Carlsbad. CA Non Profit/Trust _T.!-'o~se!..!:hi~ko~M~u!..!:ro:.z.:va~----­ Title Trustee Address PO Box 131016. Carlsbad. CA 4. Have you had more than $250 worth of business transacted with any member of City staff, Boards, Commissions, Committees and/or Council within the past twelve (12) months? DYes C8J No If yes, please indicate person(s): -------------- NOTE: Attach additional sheets if necessary. I certify that all the above information is true and correct to the best of my knowledge. ~-l11tutf--~.!J;;c_6-~rt7& Signature of owner/date /J /Ct',e.A I-f J~o /A- -~~54/,k~ dt;~P(/f Print or type name of owner Signature of owner/applicant's agent if applicable/date Print or type name of owner/applicant's agent H:ADMIN\COUNTER\DISCLOSURE STATEMENT 5/98 Signature of applicant/date Print or type name of applicant Page 2 of 2 c CERTIFICATE OF RESOLUTION OF 0 TAYLOR WOODROW HOMES, INC. The undersigned, being the Secretary of Taylor Woodrow Homes, Inc., a California corporation (the "Corporation"), does hereby certify that on June 12, 2006 the following resolutions were duly and regularly passed and adopted in all respects as required by law and the Bylaws of the Corporation and that such resolutions are still in full force and effect and have not been amended, modified, revoked or rescinded: RESOLVED, that as of the date set forth below, Gilbert J. Miltenberger, formerly the Vice President of the South Division of the Corporation, is appointed to the position of Southern California Vice President. RESOLVED FURTHER, that in his capacity as Southern California Vice President, acting alone or jointly with other officers of the Corporation, be, and hereby is authorized to execute on behalf of the Corporation any and all documents and to take such action as he may deem necessary or advisable in order to carry out the purposes of the Corporation and these resolutions as same may be related to the business, management and operations of the Corporation in Southern California. Dated: December 4, 2006 Donald D. Steffensen, Jr., Secretary 1 _,. ' City of Carlsbad I#IJFI,J.ii.t.I•J§.Jjji .. t§.il HAZARDOUS WASTE AND SUBSTANCES STATEMENT Consultation OfLists of Sites Related To Hazardous Wastes (Certification of Compliance with Government Code Section 65962.5) Pursuant to State of California Government Code Section 65962.5, I have consulted the Hazardous Wastes and Substances Sites List compiled by the California Environmental Protection Agency and hereby certify that (check one): · [8J The development project and any alternatives proposed in this application are not contained on the lists compiled pursuant to Section 65962.5 of the State Government Code. 0 The development project and any alternatives proposed in this application are contained on the lists compiled pursuant to Section 65962.5 of the State Government Code. APPLICANT Name: Taylor Woodrow Homes, Inc Address: 167 45 W. Bernardo Drive Ste 140 San Dieao. CA 92127 Phone Number: (858) 943-5100 Address of Site: None assigned yet. PROPERTY OWNER Name: Muroya Family Trust 05-18-98 Address: PO Box 131016 Carlsbad CA 92013 Phone Number: (858) 943-5100 Local Agency (City and County): City of Carlsbad, County of San Diego Assessor's book, page, and parcel number:--=2:...:.1.::..5-...:0..:..40=--..:.0.::..3 ---------------- Specify list(s):_~N'L!.A:L-__________________________ _ Regulatory Identification Number:_....!N.:!L,!;!A _______ ___,.. ____________ _ Date ofList:_·~N!L!A:L----------------------------- AclminiCowllcr!HazWurc 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 (i I I L {""" '-"' PLEASE NOTE: · Time limits on the processing of discretionary projects established by state law do not start until a project application is deemed complete by the City. The City has 30 calend;:tr days from the date of application submittal to determine whether an application is complete or incomplete. Within 30 days of submittal of this application you will receive a letter stating whether this application is complete or incomplete. If it is incomplete, the letter will state what is needed to make this application complete. When the application is complete, the processing period will start upon the date of the completior;liE~tt~. ' ;' ' / / /// / / /> / j/ ; 'i Applicant Signature: / .--'/ i ,F Staff Signature: (\ Ji~j Date: \ c· I \:Jio ~~, ' t? • To be stapled with receipt to the application • Copy for file Form 20 STATEMENT OF AGREEMENT TENTATIVE PARCEL MAP CITY OF CARLSBAD The Subdivision Map Act and the Carlsbad Municipal Code sets a fifty (50) day time restriction on Engineering Department processing. This time limit can only be extended by the mutual concurrence of the Applicant and the City. By accepting applications for Tentative Parcel maps concurrently with applications for other approvals which are prerequisites to the Map (i.e., Environmental Assessment, Environmental Impact Report, Condominium Plan, Planned Unit Development, etc.), the fifty (50) day time limits are often exceeded. If you wish to have your application processed concurrently, this agreement must be signed by the Applicant or his agent. If you choose not to sign the statement, the City will not accept your application for the Tentative Parcel Map until all prior necessary entitlements have been processed and approved. The Undersigned understands that the processing time required by the City may exceed the time limits; therefore, the Undersigned agrees to extend the time limits for City Engineer action and fully concurs with any extensions of time up to one (1) year from the date the application was accepted as complete to properly review all of the applications. Name (please print) Date .. RelatlShip to Application (Property Owner/Agent) H:/Development Services/Masters/Applications-Counter/Statement of Agreement Tentative Parcel Map 5/19/00 Bakersfield 661.334.27 55 0 0 ENVIRONMENTALSERVICES • PLANNING. NATURALRESOURCESMANAGEMENT MEMORANDUM Date: December 11, 2006 To: Ms. April Tornillo, Taylor Woodrow Homes, Inc From: Jennifer M. Sanka, M.A., Staff Archaeologist Subject: Summary of Cultural and Paleontological Resource Findings for the Taylor Woodrow, Inc. Muroya Project in the City of Carlsbad, San Diego County, California At the request of Ms. April Tornillo, Michael Brandman Associates (MBA) has conducted a Phase I cultural and paleontological resource assessment at the proposed Project Area located in the City of Carlsbad, San Diego County, California. The.detailed Phase I Cultural Resources Assessment will be available in the forthcoming document entitled: Phase I Cultural Resources Assessment and Paleontological Records Review Muroya Project City of Carlsbad, San Diego County, California (MBA, 2006). The following information has been adapted from this Phase I report. Project Location and Description Totaling approximately 20 acres, the Muroya Project Area can be found on the Encinitas, California, United States Geological Survey (USGS) 7.5-minute topographic quadrangle map, in the northern half of section 27 of Township 12 South, Range 4 West. Specifically, the Project Area is located west of Black Rail Road, north of Aviara Parkway and east of Towhee Lane. The proposed use of the Project Area is for future residential development. Summary of Cultural Resource Findings On November 28, 2006, MBA Consulting Archaeologist Jonathan Wright conducted a records search at the South Coastal Information Center (SCIC), which is located at San Diego State University. According SCIC files, approximately 75 previously known cultural resources are recorded within the 0. 75 mile search radius. One of these cultural resources is located in the southern portion of the plant nursery, which presently occupies the northern and eastern portions of the overall Project Area. MBA Project Archaeologist Jennifer M. Sanka surveyed the Project Area on December 3 and 5, 2006. As a result of the pedestrian survey, an additional isolated cultural resource was identified. Fresno 559.497.0310 Irvine '14.508.4100 '>V\VW. branclman.com Palm Springs 760.322.88+7 Sacramento 916.383.09-IA San Bernardino 909.884.2255 San Ramon 925.830.2733 mba@branclman.com Santa Cruz 831.262.1731 ... Ms. April Tornillo December 11, 2006 Page2 c Summary of Paleontological Resource Findings 0 The paleontological review, conducted by Margaret M. Hart, Lab Manager of the San Diego Natural History Museum (SDNHM), showed that the sedimentary rocks mapped in the vicinity of the Project Area are middle Pleistocene Terrace Deposits (approximately 0.5 to 1 million years old) which correlate with the Lindavista Formation, as well as middle Eocene Santiago Formation sediments ( 45 to 49 million years old). Excavation within the Project Area would likely impact deposits of the Lindavista Formation, the Santiago Formation and Torrey Sandstone. While deposits of the Lindavista Formation and Torrey Sandstone have moderate paleontological sensitivity, sediments belonging to the Santiago Formation are assigned high sensitivity. Any fossils recovered from these sediments have high potential to be considered scientifically significant. The review additionally revealed that there are 32 known paleontologic resource localities within the 1 mile search radius. Three of these localities are situated directly south ofthe proposed Project Area. Cultural Resource Recommendations Due to the presence of the numerous cultural resources within the 0.75 mile search radius, the known resource within the Project Area boundaries and the previously undocumented isolated cultural resource finding during the pedestrian survey, MBA finds that the Project Area has a high probability for retaining intact, subsurface cultural resources. Therefore, MBA recommends that cultural resource monitoring take place during all ground disturbing activities associated with the proposed development. This monitoring program should be developed prior to any grading within the Project Area. MBA also recommends that Native American monitoring take place if required or recommended by the City of Carlsbad. Paleontological Resource Recommendations Due to the high sensitivity designation of sediments from the Santiago Formation and the presence of the numerous paleontological resource localities within the 1 mile search radius, many of which were recovered from sediments similar to those present within the Project Area, MBA finds that the Project Area has a high probability for retaining significant, nonrenewable paleontological resources. Therefore, MBA recommends that paleontological resource monitoring take place during all ground disturbing activities associated with the proposed development. This monitoring program should be developed prior to any grading within the Project Area and should be consistent with the provisions of CEQA. JMS:ji H:\Client (PN-JN)\l617\l6170007\Cultural\l6170007_Memo to Ms. Tomillo.doc ('r 1 2 3 4 5 6 7 8 9 0 10 11 12 13 14 15 16 Name 0 #!# Taylor Woodrow Taylor Woodrow Homes, Inc. South Division-Southern California 16745 W. Bernardo Dr. Suite 140 San Diego, CA 92127 6600 Block Black Rail Road -Muroya Property Neighborhood Meeting, November 14th Olympic Resort Hotel and Spa -Savannah Room, 6111 El Camino Real, Carlsbad, CA 92011 SIGN -IN SHEET Home Address Please check here if interested in add. Info. ~~~ .v Order Number: Title Officer: Phone: Fax No.: E-Mail: Escrow Officer: Phone: Fax No.: E-Mail: Buyer: Owner: Property: Order Number: DIV-1387671 (MR) Page Number: 1 Updated 12-7-2006 First American Title Company 411Ivy Street San Diego, CA 92101 DIV-1387671 (MR) Moon Rash (619)231-4656 (866)559-1850 mrash@firstam.com Karen Hagen (KH) (619)768-4046 (866)414-9488 khagen@firstam.com Taylor Woodrow Homes, Inc. Akira Muroya and Toshiko Muroya 6521 El camino Real Carlsbad, CA PRELIMINARY REPORT In response to the above referenced application for a policy of title insurance, this company hereby reports that it is prepared to issue, or cause to be issued, as of the date hereof, a Policy or Policies of Title Insurance describing the land and the estate or interest therein hereinafter set forth, insuring against loss which may be sustained by reason of any defect, lien or encumbrance not shown or referred to as an Exception below or not excluded from coverage pursuant to the printed Schedules, Conditions and Stipulations of said Policy forms. The printed Exceptions and Exclusions from the coverage of said Policy or Policies are set forth in Exhibit A attached. Copies of the Policy forms should be read. They are available from the office which issued this report. Please read the exceptions shown or referred to below and the exceptions and exclusions set forth in Exhibit A of this report carefully. The exceptions and exclusions are meant to provide you with notice of matters which are not covered under the terms of the title insurance policy and should be carefully considered. It is important to note that this preliminary report is not a written representation as to the condition of title and may not list all liens, defects, and encumbrances affecting title to the land. This report (and any supplements or amendments hereto) is issued solely for the purpose of facilitating the issuance of a policy of title insurance and no liability is assumed hereby. If it is desired that liability be assumed prior to the issuance of a policy of title insurance, a Binder or Commitment should be requested. Rrst American Title RECEIVED DEC 1 :~ ?~06 CITY OF CARLSBAD PLANNING DEPT Dated as of December 1, 2006 at 7:30 A.M. Order Number: DIV-1387671 (MR) Page Number: 2 The form of Policy of title insurance contemplated by this report is: To be determined A specific request should be made if another form or additional coverage is desired. litle to said estate or interest at the date hereof is vested in: Akira Muroya and Toshiko Muroya, Trustees of the Muroya Family Trust dated May 18, 1998 The estate or interest in the land hereinafter described or referred to covered by this Report is: A fee. The Land referred to herein is described as follows: (See attached Legal Description) At the date hereof exceptions to coverage in addition to the printed Exceptions and Exclusions in said policy form would be as follows: 1. General and special taxes and assessments for the fiscal year 2006-2007. First Installment: $2,398.56, Due Penalty: $239.86 Second Installment: $2,398.56, Open Penalty: $249.86 Tax Rate Area: 09165 A. P. No.: 215-040-03-00 2. The lien of supplemental taxes, if any, assessed pursuant to Chapter 3.5 commencing with Section 75 of the California Revenue and Taxation Code. 3. Rights of the public in and to that portion of the land lying within roads, streets or highways. 4. An easement for public utilities and incidental purposes, recorded February 28, 1957 as Book 6475, Page 552 of Official Records. In Favor of: San Diego Gas and Electric Company Affects: A portion of the herein described property Rrst American Title Order Number: DIV-1387671 (MR) Page Number: 3 5. An easement for roadway purposes and right of way for installation of public utilities and pipelines and incidental purposes, recorded August 26, 1960 as instrument no. 174500 of Official Records. In Favor of: Frank H. Ayres and Son, a corporation Affects: A portion of the herein described property 6. An easement for a pipeline or pipelines for any and all purposes, together with their necessary fixtures and appurtenances including but not limited to conduits, and cables for power transmission and communication purposes, together with the right of ingress thereto and egress therefrom, to and along said right of way by a practical route or routes and incidental purposes, recorded August 14, 1961 as instrument no. 139572 of Official Records. In Favor of: Carlsbad Municipal Water District Affects: A portion of the herein described property 7. An easement for public utilities and incidental purposes, recorded June 24, 1965 as instrument no. 113006 of Official Records. In Favor of: San Diego Gas and Electric Company Affects: A portion of the herein described property 8. An easement for public utilities and incidental purposes, recorded June 16, 1966 as instrument no. 99308 of Official Records. In Favor of: San Diego Gas and Electric Company Affects: A portion of the herein described property 9. The effect of an easement for a pipeline or pipelines for any and all purposes, together with their necessary fixtures and appurtenances including but not limited to conduits and cables for power transmission and communication purposes, together with the right of ingress thereto and egress therefrom to and along said right of way by a practical route or routes and incidental purposes in favor of carlsbad Municipal Water District, recorded January 5, 1977 as file no. 77-003537 of Official Records, described as follows: An easement sixty feet in width, the center line of said easement of right of way is particularly described as follows: Beginning at the South quarter corner of Section 22, Township 12 South, Range 4 West, San Bernardino Base and Meridian, according to United States Government Survey Approved April 21, 1890; thence Northerly along the North-South centerline of Section 22, 990 feet, more or less, to the Northwest corner of the Southwest quarter (SW 1/4) of the Northwest quarter (NW 1/4) of the Southwest quarter (SW 1/4) of the Southeast quarter (SE 1/4) of said section 22, said point being the true point of beginning; thence southerly retracing the north-south centerline of said section 22, 990 feet more or less, to the intersection with the northerly line of Section 27, Township 12 South, Range 4 West, San Bernardino Base and Meridian, according to United States Government Survey approved April 21, 1890; thence continuing southerly along the north- south centerline of said section 27, 1,320 feet. Reference is made to said instrument for further particulars. At the date of said instrument Frank H. Ayres and son, a corporation had no record interest in said land nor since acquired any. Rrst American 77tle 0 Order Number: DIV-1387671 (MR) Page Number: 4 10. The fact that said land lies within the bridge and thoroughfare district no. 2 (Aviara Parkway- Poinsettia Lane), as disclosed by instrument recorded July 22, 1997 as file no. 1997-0349124 of Official Records. 11. An easement for public street and public utility purposes and incidental purposes, recorded March 2, 1998 as instrument no. 98-0107903 of Official Records. In Favor of: Affects: City of Carlsbad, a Municipal corporation A portion of the herein described property Said instrument also grants the privilege and right to extend and maintain drainage structures and excavation and embankment slopes beyond the limits of said right of way where required for the construction and maintenance thereof. 12. Prior to the issuance of any policy of title insurance, the Company will require: With respect to the trust referred to in the vesting: a. A certification pursuant to Section 18100.5 of the California Probate Code in a form satisfactory to the Company. b. Copies of those excerpts from the original trust documents and amendments thereto which designate the trustee and confer upon the trustee the power to act in the pending transaction. c. Other requirements which the Company may impose following its review of the material required herein and other information which the Company may require. Rrst American Tttle c Order Number: DIV-1387671 (MR) Page Number: 7 LEGAL DESCRIPTION Real property in the City of Carlsbad, County of San Diego, State of California, described as follows: THE EAST ONE-HALF OF THE NORTHEAST QUARTER OF THE NORTHWEST QUARTER, SECTION 27, TOWNSHIP 12 SOUTH, RANGE 4 WEST, SAN BERNARDINO BASE AND MERIDIAN, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO UNITED STATES GOVERNMENT SURVEY. APN: 215-040-03-00 Rrst American Title c 0 SAN DIEGO COUNTY REGIONAL AIRPORT AUTHORITY AIRPORT LAND USE COMMISSION (ALUC) NOTICE OF PUBLIC HEARING PROJECT /LOCATION: San Diego County Regional Airport Authority Airport Land Use Commission Determination -6697 Black Rail Road, City of Carlsbad; General Plan Amendment and Zone Reclassification to construct 37 single-family residential units; APN 215-040-03; McClellan-Palomar Airport, Airport Land Use Compatibility Plan LOCAL JURISDICTION: City of Carlsbad Mr. Dan Halverson 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4631 A public hearing on the above referenced project will be held by the San Diego County Regional Airport Authority, acting in its capacity as the Airport Land Use Commission (ALUC) for the County of San Diego, on May 6, 2010. The ALUC will follow the conclusion of the Airport Authority Board meeting, which begins at 9:00 am. The hearing will be held in the Commuter Terminal, 3rd Floor, 3225 N. Harbor Drive, San Diego, California 92101. Please check Authority web site for any possible changes to dates and times of meetings. Persons are invited to attend the public hearing and provide oral or written comments regarding the project. The project will be described and a staff recommendation will be given. Copies of the agenda, staff report, and draft resolution will be available on SDCRAA's web site no later than Monday, May 3. http://www.san.org/sdcraa/leadership/staff reports.aspx?tvpe=aluc. If you have any questions please contact Ed Gowens, SDCRAA, Airport Planner (619) 400-2244 or egowens@san.org. -~----------------------------------~---~-·-·· ·----- SAN DIEGO COUNTY REGIONAL AIRPORT AUTHORITY Airport Land Use Commission · P. 0. Box 82776 ·San Diego, California 92138-2776 APPLICATION FOR DETERMINATION OF CONSISTENCY Project Address: 6697 Black Rail Road, Carlsbad, CA 92008 Assessor's Parcel Number(s): _2_1_5_-0_4_0_-0_3 ______________________ _ Jurisdiction: City of Carlsbad Jurisdiction Project Manager: Dan Halverson, Assistant Planner Address: 1635 Faraday Avenue, Carlsbad, CA, 92008 Telephone number: 760-602-4631 Fax number: 760-602-8559 ---------------Email address: Daniei.Halverson@carlsbadca.gov Brief Project Description: The grading and development of a 20.27 acre site, currently a palm tree farm and family residence, into 5 lots (2 residential, 2 open space, and 1 private roadway) and construct 37 detached air-space condominium single family residences and retaining the existing residence for 38 units. Height ofbuilding(s) above grade: ~Maximum feet above mean sea level: 364 Lot coverage: 12.8% Total square footage of building space: Area of property in square feet: ..::.8.:.8_:_2:_.:_,9.:.6_1 ___ _ Date project was deemed complete per Government Code: Floor Area Ratio: ------ Attach the following documents to this application: (I) Property deed or title report listing current owner of record (2) Assessor's parcel map page showing property (3) FAR Part 77 determination of hazard (if applicable) ( 4) Project site plans with floor plans and dimensioned elevations The San Diego County Regional Airport Authority, acting in its capacity as the local Airport Land Use Commission (ALUC), reserves its right to request additional information and documents regarding any proposed project submitted for a consistency determination. The submittal shall not be deemed complete by the Authority until such time as all required documents and information, as determined by Authority staff, have been submitted and reviewed for completeness. Any determination rendered by the Authority is limited to the project plans and description submitted with this application and is not transferable to any revision ofthis or any similar, future project involving any change in the use, area, or height of structures as depicted and described therein. Any changes in these project characteristics subsequent to Authority review but before decision-making consideration by the local jurisdiction must be resubmitted via new application to the Authority for a new determination of consistency. As representative of the local jurisdiction named above, I hereby certify that I understand the foregoing statements and further that this application and attached documents constitute a true and correct statement of facts to the best of my knowledge. Project Manager Signature: ___________________ Date: _________ _ BELOW FORST AFF USE ONLY AlA---------------AAOZ limit __ _ RPZ FAZ APZ zone __ _ CNEL (dB): outside 60 60-65 65-70 70-75 75-80 80+ Max Elev AMSL ____ _ Latitude 0 __ _ ___ " North Longitude o __ _ __ __ .. West FAA Notification Required? Y I N USMC Review Letter? Y I N PrintForm ] ' ' ~ . ~CARLSBAD 0 0 FILE COPY 3·0>&J•Io Planning Department www.carlsbadca.gov NOTICE OF PUBLIC HEARING NOTICE IS HEREBY GIVEN to you that the Planning Commission of the City of Carlsbad will hold a public hearing at the Council Chambers, 1200 Carlsbad Village Drive, Carlsbad, California, at 6:00 p.m. on Wednesday, April7, 2010, to consider a request for the following: CASE NAME: GPA 06-09/ZC 06-08/SP 203(D)/LCPA 06-09/CT 06-27/CP 06-19/CDP 06- 32/HDP 06-10/HMP 07-02-Muroya Subdivision PUBLISH DATE: March 26, 2010 DESCRIPTION: Request for a recommendation of adoption of a Mitigated Negative Declaration and Mitigation Monitoring and Reporting Program; a recommendation of approval for a General Plan Amendment, Zone Change, Local Coastal Program Amendment, and a Specific Plan Amendment; and a request for approval of a Tentative Tract Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit, and Habitat Management Plan Permit for the subdivision of a 20.27-acre site into five (5) lots (two residential, two open space lots, and one private street lot) and the grading and development of 37 detached air-space condominium one-family dwelling units on property located north of Aviara Parkway, south of Corte Orchidia, east of Towhee Lane, and west of Black Rail Road, and within the Mello II Segment of the Local Coastal Program and Local Facilities Management Zone 20. Those persons wishing to speak on this proposal are cordially invited to attend the public hearing and provide the decision makers with any oral or written comments they may have regarding the project. Copies of the staff report will be available online at http://www.carlsbadca.gov/planning/pcvideo.html on or after the Friday prior to the hearing date. If you have any questions, or would like to be notified of the decision, please contact Dan Halverson in the Planning Department at (760) 602-4631, Monday through Thursday 7:30a.m. to 5:30p.m., Friday 8:00a.m. to 5:00p.m. at 1635 Faraday Avenue, Carlsbad, California 92008. APPEALS The time within which you may judicially challenge these projects, if approved, is established by State law and/or city ordinance, and is very short. If you challenge this project in court, you may be limited to raising only those issues you or someone else raised at the public hearing described in this notice or in written correspondence delivered to the City of Carlsbad at or prior to the public hearing. o Appeals to the Citv Council: Where the decision is appealable to the City Council, appeals must be filed in writing within ten (10) calendar days after a decision by the Planning Commission. o Coastal Commission Appealable Project [8J [8J This site is not located within the Coastal Zone Appealable Area. Application deemed complete: 02/02/2010 Where the decision is appealable to the Coastal Commission, appeals must be filed with the Coastal Commission within ten (10) working days after the Coastal Commission has received a Notice of Final Action from the City of Carlsbad. Applicants will be notified by the Coastal Commission of the date that their appeal period will conclude. The San Diego office of the Coastal Commission is located at 7575 Metropolitan Drive, Suite 103, San Diego, California 92108-4402. CITY OF CARLSBAD PLANNING DEPARTMENT T (760) 602-4600 F (760) 602-8559 • N NOT TO SCALE Muroya Subdivision GPA 06-09 I ZC 06-08 I SP 2030 I LCPA 06-09 I CT 06-27 I CP 06-19 I COP 06-32 I HOP 06-10 I HMPP 07-02 _4f~.A._ C I T Y 0 F VcARLSBAD Planning Department AprilS, 2010 Jack Henthorn Jack Henthorn & Associates 5365 Avenida Encinas, Suite A Carlsbad, CA 92008 PLANNING COMMISSION NOTICE OF DECISION AdOO 311~ www.carlsbadca.gov SUBJECT: GPA 06-09/ZC 06-08/SP 203(D)/LCPA 06-09/CT 06-27/CP 06-19/CDP 06- 32/HDP 06-10/HMP 07-02-MUROYA SUBDIVISION At the April 7, 2010 Planning Commission meeting, your application was considered. The Commission voted 5-0 to Recommend Adoption/Recommend Approval/Approve of your request. The decision of the Planning Commission is advisory and will be forwarded to the City Council. If you have any questions regarding the final dispositions of your application, please contact your project planner Dan Halverson at (760) 602-4631 or daniel.halverson@carlsbadca.gov. DON NEU Planning Director DN:DH:bd cc: Data Entry File Enclosed: Planning Commission Resolutions No. 6681, 6682, 6683, 6684, 6685, 6686, 6687, 6688, 6689, and 6690 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T (760) 602-4600 F (760) 602-8559 PROOF OF PUBLICATION (2010 & 2011 C.C.P.) STATE OF CALIFORNIA County of San Diego I am a citizen of the United States and a resident of the County aforesaid: I am over the age of eighteen years and not a party to or interested in the above- entitled matter. I am the principal clerk of the printer of North County Times Formerly known as the Blade-Citizen and The Times- Advocate and which newspapers have been adjudicated newspapers of general circulation by the Superior Court of the County of San Diego, State of California, for the City of Oceanside and the City of Escondido, Court Decree number 171349, for the County of San Diego, that the notice of which the annexed is a printed copy (set in type not smaller than nonpariel), has been published in each regular and entire issue of said newspaper and not in any supplement thereof on the following dates, to-wit: February 17th, 2010 I certify (or declare) under penalty of perjury that the foregoing is true and correct. Dated at Escondido, California Jane AI s ouse NORTH COUNTY TIMES Legal Advertising This space is for the County Clerk's Filing Stamp CITY OF CARLSBAD FEB 2 2 2010 PLANNING Dt:t'ARTMENT Proof of Publication of CASE NAIIIIE: Mllli!Yl! CASE NO: G,fA -PA ~ ~ 06-27/CP06- ~06-32/HDP -1 PROJECT LOCATION: l:!!Q!!!J Qj Aviara Parkway, south 2! ~ Orchidia, east Qj ~ ~ ruJ2 ~ Qj ~ .B.ai! .BQM (APN 215-040-031. PROJECT DESCRIPTION: The proposed project involves a General Plan Amendment (GPA), Zone Change (ZC), Local Coastal Program Amendment (LCPA), SpecHic Plan Amendment (SPA), Tentative Tract Map (CT), Condo- minium Permit (CP), Coastal Development Permit (CDP), Hillside Develop- ment Permit (HDP), Habitat Management Plan Permit (HMPP) to allow for the subdivision and development of a 20.27 acre parcel (APN 215-040-03) located north of Aviara Parkway, south of Corte Orchidia, east of Towee Lane, and west of Black Rail Road. The Parcel will be subdivided into five (5) separate lots. Lot 1 is approximately 6.3 acres in size and will contain 37 detached con- dominium units clustered in the northern and eastern portions of the lot. Lot 2 is 0.9 acres in size and is the site of the owners existing residence which will remain on this parcel. Lot 3 and 4 are 1.6 acres and 9.8 acres in size and will be open space lots (lot 3 as a buffer zone and lot 4 as open space habitat). Lot 5 is a 0. 7 acre size lot which will be developed as private road for common access to the 37 detached condominium units. The current General Plan and Local Coastal Program Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with the Local Coastal Program and Zoning classification as L-C (Limited Control). The General Plan Amendment and LCPA will change the two (2) proposed open space lots 3 and 4 from RLM to OS (Open Space), the pro- posed residential lot 1 and the proposed private street lot 5 from RLM to AM (Residential Medium Density, 4-8 dwelling units per acre), with lot 2 remaining RLM . Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots (3&4) will change from L-C to OS (Open Space), the zoning for the residential lots (1 &5) will change from L-C to RP-M (Residential Density -Medium), and lot 2 will change from L·C to Single Family Residential (R-1). PROPOSED DETERMINATION: The City of Carlsbad has conducted an en- vironmental review of the above described project pursuant to the Guidelines for Implementation of the California Environmental Quality Act (CEQA) and the Environmental Protection Ordinance of the City of Carlsbad. As a result of said review, the initial study (EIA Part 2) identified potentially significant effects on the environment, but (1) revisions in the project plans or proposals made by, or agreed to by, the applicant before the proposed negative declaration and initial study are released for public review would avoid the effects, or mitigate the effects to a point where clearly no significant effect on the environment would occur, and (2) there is no substantial evidence in light of the whole record be- fore the City that the project "as revised" may have a significant effect on the environment. Therefore, a Mitigated Negative Declaration will be recom- mended for adoption by the City of Carlsbad City Council. A copy of the initial study (EIA Part 2) documenting reasons to support the proposed Mitigated Negative Declaration is on file in the Planning Department, 1635 Faraday Avenue, Carlsbad, California 92008. Comments from the public are invited. Pursuant to Section 15204 of the CEQA Guidelines, in reviewing Mitigated Negative Declarations, persons and public agencies should focus on the proposed finding that the project will not have a significant effect on the environment. If persons and public agencies believe that the project may have a significant effect, they should: (1) identify the specific effect; (2) explain why they believe the effect would occur; and (3) explain why they believe the effect would be significant. Please submit comments in writing to the Planning De- partment within 30 days of the date of this notice. The proposed project and Mitigated Negative Declar~tion are subject to review and approvaVadoption by the City of Carlsbad Planmng Comm1ss1on and City Council. Additional public notices will be issued when those pubhc heanngs are scheduled. If you have any questions, please call Dan Halverson 1n the Planning Department at (760) 602-4631. PUBLIC REVIEW PERIOD: ~ lL ZlUQ: .Ml!rd:Jla. ZlUQ PUBLISH DATE: Eill!YA..ry lL gQ1Q NCT 2249033 PROOF OF PUBLICATION (2010 & 2011 C.C.P.) STATE OF CALIFORNIA County of San Diego I am a citizen of the United States and a resident of the County aforesaid: I am over the age of eighteen years and not a party to or interested in the above- entitled matter. I am the principal clerk of the printer of North County Times Formerly known as the Blade-Citizen and The Times- Advocate and which newspapers have been adjudicated newspapers of general circulation by the Superior Court of the County of San Diego, State of California, for the City of Oceanside and the City of Escondido, Court Decree number 171349, for the County of San Diego, that the notice of which the annexed is a printed copy (set in type not smaller than nonpariel), has been published in each regular and entire issue of said newspaper and not in any supplement thereof on the following dates, to-wit: December 25th, 2009 I certify (or declare) under penalty of perjury that the foregoing is true and correct. Dated at ESCONDIDO, California This ~day of Decembt:J-.J::'=A.I I Jane Allshouse NORTH COUNTY TIMES Legal Advertising This space is for the County Clerk's Filing Stamp Proof of Publication of Please be advised that t!'le City of Carlsbad is consideriqg text amendments to 1ts LQ:Cal Coastal Prc;>-gram {LCI-') as summarized below. :Th1s amendment IS oeing proposed by the Muroya Fam1ly Trust an<~ 1s cur-rently under review. T~is notice herE!bY o_pens ~ S!X week review period after wh1ch the Planning CommiSSIOn and City Council will consider all comments ancj a9t on the proposed amendment. The Pl~nmng_ CommiSSIOn hear-Ing is expected to take glace 1.n Apnl. 2010. and Will be duly noticed. The City Counc.1l heanng 1s .expected to take place in May 2010, and w1ll be duly not1ced. Copies of the LCP amendment are available f9r review at the following locations: {1) Carlsbad.Pianmnj\1 Dep!lrt-ment, 1635 Faraday Avenue· {2\ C1ty Cler~ s Qfhce, 1200 Carlsbad Village Drive; {:~1) Carlstiad Main L1brary, 1775 Dove Lane; { 4) Georgina ColE! Libral\', 1250 Carls-bad Village Drive· and .(5) thE! Cahfqrma Coastal <;:om-mission 7575 Melropohtan Dnve, SUite 103, San D1ego, CA 921 bB-4402 PROPOSED LCP AMENDMENT SUMMARY LCPA 06-09 -MUROYA SUBDIVISION This specific Local Coastal Program Map Amendment is proposed as follows: The project site is af:jproximately 20.27 acres in size and is located north of Aviara Parl<way south of Corte Or-chidia and west of Black Rail Road (APN 215-040-03). The 8roject site is located within the Mello II Seg_ment of the ity of Carlsbad Local Coastal Program. The pro-P.Osed project includes a Local Coastar Program MaP. Amendment {LCPA 06-09) to. change the Locai .Coastal Prog_ram Land Use designation from Res!dent!al Low-Medium Density (fiLM (J-4 dulac) to f'lesld!Jntlal L!)w-Medium Density (RLM 0-4 dulac), Res1dent1al Med1um Density (RM 4-ll dulac) and Open Spa9e (OS) and to change the Local Coaslal Program zom~g des1gnat1c;>n from 'Limited Control {L-C) to Qne-FamiiY Residential (R-1), Residential Density-Multiple {RD-M), and Open Space {OS). The proposed project also includes a Tentative Subdivi-sion MaR (CT 06-27) Condominium Permit IGP .06-19), Coastal Developmenl Permit ~COP 06-321 .. H1lls1de De-velopment Permit IHDP 06-1 0 and a Hab1tat Manage-ment Plan Permit {HMPP 07-0 )\to allow fqr the. subdivi-sion of the 20.27-acre site into Slots (1 resldenlll!l lot for future development of 37 detached. cc;>ndormmums,, 1 residential lot to retain the owners ex1stmg single-family residence 1 lot for a road el!sement, and~ open space lots for buller zones and hab1tat preservation). If you have any questions, please call Dan Halversqn in the Planning Department at {760) 602-4631. Wntten comments sflould be sent to the Plan~ing ,Del)artm_ent at 1635 Faraday Avenue, Carlsbad, Cal1fom1a 92008 PUBLISH DATE: December 25, 2009 NCT 2242010 CITY OF CARLSBAD DEC 3 0 2009 P' • -~ J The Coast vews Decreed A Legal Newspaper by the Superior Court of San Diego County. Mail all correspondence regarding public notice advertising to The Coast News, P.O. Box 232-550, Encinitas, CA 92023 (760) 436-9737 Proof of Publication STATE OF CALIFORNIA, ss. COUNTY OF SAN DIEGO, I am a citizen of the United States and a resident of the county aforesaid; I am over the age of eighteen years, and not a party to or interested in the above entitled matter. I am principal clerk of the printer of The Coast News, a newspaper printed and published weekly and which news- paper has been adjudged a newspaper of general circulation for the cities of Del Mar, Solana Beach, Encinitas/Cardiff, Carlsbad, Oceanside, San MarcosNista and the County Judicial District by the Superior Court of the State of California, County of San Diego (8/4/94, #677114, B2393, P396); and that the notice , of which the annexed is a print- ed copy, has been published in, each regular and entire issue of said newspaper and not in any supplement thereof on the following dates, to-wit: December 25. 2009 I certify under penalty of perjury that the foregoing is true and correct. Executed at Encinitas, County of San Diego, State of California on the 28th day of December, 2009 U~D.~ Clerk of the Printer I Space above for County Clerk's Filing Stamp (j CITY OF CARLSBAD PUBLIC NOTICE TO INTERESTED PARTIES: Please be advised that the City of Carlsbad is con- sidering text amendments to its Local Coastal Program (LCP) as summarized below. This amendment is being proposed by the Muroya Family Trust and is currently under review. This notice hereby opens a six week review period after which the Planning Commission and City Council will consider all comments and act on the proposed amendment. The Planning Commission hearing is expected to take place in April 2010, and will be duly noticed. The City Council hearing is expected to take place in May 2010, and will be duly noticed. Copies of the LCP amendment are available for review at the fol- lowing locations: (1) Carlsbad Planning Department, 1635 Faraday Avenue; (2) City Clerk's Office, 1200 Carlsbad Village Drive; (3) Carlsbad Main Library, 1775 Dove Lane; (4) Georgina Cole Library, 1250 Carlsbad Village Drive; and (5) the California Coastal Commission, 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402 PROPOSED LCP AMENDMENT SUMMARY LCPA 06-09 -MUROYA SUBDIVISION This spec~ic Local Coastal Program Map Amendment is proposed as follows: The project site is approximately 20.27 acres in size and is located north of Aviara Parkway, south of Corte Orchidia, and west of Black Rail Road (APN 215-040-03). The project site is located within the Mello II Segment of the City of Carlsbad Local Coastal Program. The proposed project includes a Local Coastal Program Map Amendment (LCPA 06-Q9) to change the Local Coastal Program Land Use designation from Residential Low-Medium Density (RLM Q-4 dulac) to Residential Low-Medium Density (RLM 0-4 dulac), Residential Medium Density (AM 4-8 dulac), and Open Space (OS) and to change the Local Coastal Program zoning designation from Limited Control (L-C) to One-Family Residential (A-1), Residential Density-Multiple (AD-M), and Open Space (OS). The proposed project also includes a Tentative Subdivision Map (CT 06-27), Condominium Permit (CP 06-19), Coastal Development Penni! (COP 06-32), Hillside Development Permit (HOP 06-10), and a Habitat Management Plan Pennit (HMPP 07- 02) to allow for the subdivision of the 20.27-acre site into 5 lots (1 residential lot for future development of 37 detached condomini- ums, 1 residential lot to retain the owners existing single-family res- idence, 1 lot for a road easement, and 2 open space lots for buffer zones and habitat preservation). If you have any questions, please call Dan Halverson in the Planning Department at (760) 602-4631. Written comments should be sent to the Planning Department at 1635 Faraday Avenue, Carlsbad, California 92008. CN 9211 , Dec. 25,2009 - CITY OF CARLSBAD DEC 2 9 2009 PLANNING DEPArt I v NT ru 0 0 0 I U.S. Postal Servicer., CE.@TIFIED MAIL., RECEIPT - (Domestic Mail Only; No Insurance Coverage Pro~.-.:ld) . .. . ' . . -· . OFFICIAL USE Postage $ Certified Fee Retum Receipt Fee Postmark Here (Endorsement Required) J.;J • .;J I • oct Restricted Delivery Fee (Endorsement Required) _!-.<PI pto-oc;. fbbr.t. N-oti((.../l>l-+ Total Postr • • C l C · · Cahforma oasta ommtsswn Attn: Toni Ross Suite 103 7575 Metropolitan Drive San Diego, CA 921 08-4402 I c o FILE COPY lt:iJ· 0> I· 09 City of Carlsbad IQfbhiJib.lai§•Jhlllei§.JI PUBLIC NOTICE TO INTERESTED PARTIES: Please be advised that the City of Carlsbad is considering text amendments to its Local Coastal Program (LCP) as summarized below. This amendment is being proposed by the Muroya Family Trust and is currently under review. This notice hereby opens a six week review period after which the Planning Commission and City Council will consider all comments and act on the proposed amendment. The Planning Commission hearing is expected to take place in April 2010, and will be duly noticed. The City Council hearing is expected to take place in May 2010, and will be duly noticed. Copies of the LCP amendment are available for review at the following locations: (1) Carlsbad Planning Department, 1635 Faraday Avenue; (2) City Clerk's Office, 1200 Carlsbad Village Drive; (3) Carlsbad Main Library, 1775 Dove Lane; (4) Georgina Cole Library, 1250 Carlsbad Village Drive; and (5) the California Coastal Commission, 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402 PROPOSED LCP AMENDMENT SUMMARY LCP A 06-09-MUROY A SUBDIVISION This specific Local Coastal Program Map Amendment is proposed as follows: The project site is approximately 20.27 acres in size and is located north of Aviara Parkway, south of Corte Orchidia, and west of Black Rail Road (APN 215-040-03). The project site is located within the Mello II Segment of the City of Carlsbad Local Coastal Program. The proposed project includes a Local Coastal Program Map Amendment (LCPA 06-09) to change the Local Coastal Program Land Use designation from Residential Low-Medium Density (RLM 0-4 dulac) to Residential Low-Medium Density (RLM 0-4 dulac), Residential Medium Density (RM 4-8 dulac), and Open Space (OS) and to change the Local Coastal Program zoning designation from Limited Control (L-C) to One-Family Residential (R-1 ), Residential Density-Multiple (RD-M), and Open Space (OS). The proposed project also includes a Tentative Subdivision Map (CT 06-27), Condominium Permit (CP 06-19), Coastal Development Permit (CDP 06-32), Hillside Development Permit (HDP 06-10), and a Habitat Management Plan Permit (HMPP 07-02) to allow for the subdivision of the 20.27-acre site into 5 lots (1 residential lot for future development of 37 detached condominiums, 1 residential lot to retain the owners existing single-family residence, 1 lot for a road easement, and 2 open space lots for buffer zones and habitat preservation). If you have any questions, please call Dan Halverson in the Planning Department at (760) 602-4631. Written comments should be sent to the Planning Department at 1635 Faraday Avenue, Carlsbad, California 92008. PUBLISH DATE: December 25,2009 PUBLISH DATE FOR NORTH COUNTY TIMES: December 25, 2009 PUBLISH DATE FOR COAST NEWS: December 25,2009 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us (!) LCPA 06-09 LOCAL COASTAL PROGRAM AMENDMENT-LAND USE MUROYA SUBDIVISION '"'- RL~ OS EXISTING PROPOSED Related Cases File No(s): GPA 06-09/ZC 06-08/LCPA 06-09/CT 06- 27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 G. P. Map Designation Change Property From: To: A. 215-040-03 RLM RLM/RM/OS B. 0 c. D. LCPA 06-09 LOCAL COASTAL PROGRAM AMENDMENT-ZONING MUROYA SUBDIVISION P-C '""' L-C"" Related Cases File No(s): GPA 06-09/ZC 06-08/LCPA 06-09/CT 06- 27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 Zone Change Property From: To: A. 215-040-03 L-C R-1 /RD-M/0-S B. ~ C. D. c ATTACHMENT "2" CERTIFICATION OF POSTING I certify that the "Notice of Project Application" has been posted at a conspicuous location on the site on ____ _ PROJECT NAME: MUF.o-fA. ~\l<t1cN PROJEcT NUMBER: cr O<a--z-7/aah-lc., ... RETURNTO: --~~~~~Go~~~------­ (Pianner) CITY OF CARLSBAD PLANNING DEPARTMENT 1635 Faraday Avenue Carlsbad, CA 92008-7314 4 ' I 0 0 J{ll /6"1- FIL[ CDPY PROJECT NAME: PROJECT NUMBER: City of Carlsbad l:lJfhhhlh.i•J§.Fiiii•i§hl EARLY PUBLIC NOTICE Muroya Subdivision GPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/ COP 06-32/HDP 06-10 This early public notice is to let you know that a development application for a 37 unit detached condominium project within your neighborhood has been submitted to the City of Carlsbad on December 13, 2006. The project application is undergoing its initial review by the City. LOCATION: The project site is generally located on the west side of Black Rail Road, south of Corte Orchidia, north of Avena Court, and east of Towhee Lane. The 20-acre project site is currently developed with a single-family home and a palm tree nursery. PROJECT DESCRIPTION: The project proposes to develop 37 detached residential condominium units clustered in the northeasterly portion of the site with two points of access from Black Rail Road at Songbird Avenue and Ocean Crest Avenue. The existing single-family home on the south easterly portion of the project site will remain. The remaining portions of the site will be preserved in Open Space. Please keep in mind that this is an early public notice and that the project design could change as a result of further staff and public review. A future public hearing notice will be mailed to you when this project is scheduled for public hearing before the Planning Commission. CONTACT INFORMATION: If you have questions or comments regarding this proposed project please contact Jason Goff, Associate Planner at jgoff@ci.carlsbad.ca.us, (760) 602-4643, City of Carlsbad Planning Department, 1635 Faraday Avenue, Carlsbad, CA 92008. I 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us (!) / / / 1\I!!IUI..Ail5TI!I!!1.1"'1!t1CZ-6'MIN.~TO MAXIMIZ!: V11!!H ~LOT !PeGPI(;. / / / HO~~OH~~!IL.DI"'!. l1TILIZI!oti.YM.I>.T'I'It"e~AHD GOASTAL.~~~M.IC VICINTTY MAP "''""' FENCINe LE6END I'!A11!RI~PT10N GOMeO-'n..I!!JI.LAA ~TEE!.. VI~ r=eHC.e ON w.soNit'f ~-..!.-SEE DETAIL "e' SteT 4 t>' !!I.JJMP' ~ l"eRRH!T!!R HALl..-!lei!! DeTAIL 'C' !5leT 4 I'IOOD 5C101!1!!N f"'!NCe-SEE DeTAIL 'A' etl!eT 4 'IIJE!l.ILAit ,,_, Vl&ll'eiGI:-SEE DeTAIL .,. !5H!I!T 4 ~__,.I ~'Qt.~ """""""""""' II!I!S«<!T21"011t~110N~ !n!Pm!I!L ..,..,..,..,., """""" ......... -.-ref"'Ol~T............,..LI!III!IC) /IIKI .... ~TJON ZQM!! ........, _..,.4f'OIIt~~.AIL5N<O~~ !II!I!~SI"''Oti"'N!P'ItD'fl!l:.f'ION~ tee-..r 6 f"'Ol NoiroliR~A'T'IC:IN N#D ~~ ..... 121t"-AN II!I!!M!e'"tf"'R.~~ """""'""" """" J.ANDSCN>EIFENC CONCEPT PIAN MUROYA City 01 Cal1abad, Califcmla () () Plan4C Santa Barbara Plan4B Andalusiim Plan 28 Andalusian Pian 18 Andalusian Conceptual Streetscene Plan2A Adobe Ranch Pian 3A Adobe Ranch Plan 3t Santa BaTbara r 11 r w 111 _..._,_, -...,~,..._) ~ .. J/1 ........ 4 ~ .... ~U.1·0NW8 nnnfl· 1 .......... ~~~~------------------------------------~~~ ·-· T~d~U~ •• WWN-UW& Muroya Property ---------------------------------------"'..:..'---.. _UUUI_..,_.;," .. =· no· w. .c...r ""-....,_. ...... C. •• .,..-,.,. , ... _,,. Carlsbad, California o.-.-a~ ..... ~ .... ...-n..., Slteet01 City of Carlsbad Muroya Subdivision GPA 06-09/ZC 06-08/LCPA 06-09/ CT 06-27/CP 06-19/CDP 06-32/ HOP 06-10 N A 0 600 --~=====:~Feet 300 Map created by the City of Carlsbad GIS. Portions of the DERIVED PRODUCT contain geographic information copyrighted by SanGIS. All Rights Reserved ATTACHMENT "1" I HEREBY CERTIFY THAT THE PROPERTY OWNERS LIST AND LABELS SUBMITTED TO THE CITY OF CARLSBAD ON THIS DATE REPRESENT THE LATEST AVAILABLE INFORMATION FROM THE EQUALIZED ASSESSOR'S ROLES. APPLICATION NAME AND NUMBER TOR APPLICANT'S REPRESENTATIVE BY: RECEIVED BY DATE: __________________ _ 3 ... Notice of Determination To: D Office of Planning and Research P.O. Box 3044 Sacramento, CA 95812-3044 From: CITY OF CARLSBAD Planning Department 1635 Faraday Avenu1 Carlsbad, CA 92008 100173 OF CARLS~ SD County Clerk Attn: Linda Kesian Mail Stop A-33 I?Ol1t:§C0 bav ti!Mler,Recorder/County Clerk (760) 602-4600 1600 Pacific Highway San Diego, CA 921 0 1 JU L 0 8 2010 esian I • 1 3 Z01 Community & Econo1 me Development Department Project No: GPA 06-09/ZC 06-08/LCPA 06-09/ SP 203(D)!CT 06-27/CP 06-19/CDP 06-32 /HDP 06- 1 0/HMP 07-02 Filing of Notice of Determination in compliance with Section 21108 or 21152 of the Public Resources Code. Muroya Subdivision Project Title 2010021061 City of Carlsbad, Dan Halverson (760) 602-4631 State Clearinghouse No. Lead Agency, Contact Person Telephone Number North of A viara Parkway, south of Corte Orchidia, east of Towhee Lane, and west of Black Rail Road, Carlsbad, CA (San Diego County). Project Locations (include County) Name of Applicant: Taylor Morrison of CA, LLC Applicant's Address: 15 Cushing Street, Irvine, CA 92618 Applicant's Telephone Number: 858-864-6206 Project Description: A proposal to subdivide a 20.27 acre site into 5 lots (2 residential, 2 open space, and 1 private access lots) and develop 37 detached condominium single fami ly residences. This is to advise that the City of Carlsbad has approved the above described project on June 22 2010, and has made the following determination regarding the above described project. 1. The project will not have a significant effect on the environment 2. A Mitigated Negative Declaration was prepared fo:::-this project pursuant to the provisions ofCEQA. 3. Mitigation measures were made a condition of the approval of the project. 4. A mitigation reporting or monitoring plan was adopted for this project. 5. A statement of Overriding Considerations was not adopted for this project. 6. Findings were made pursuant to the provisions of CEQ A. This is to certify that the final Mitigated Negative Declaration with comments and responses ecord of project approval is available to the General Public at THE CITY OF CARLSBAD. DON NEU, City Planner Date received for filing at OPR: OUNTYCLERK ~an Diego Counzy on JUl 0 8 1010 ::>osted JUL 0 8 h Remo AUG 1 1 ?r1n .;>eturned to agenr,y on . ~fJG 1 1 Z010 oeputy ~--L~ Keslan Revised 0511 0 _I~A_ CITY OF VcARLSBAD Planning Department www.carlsbadca.gov CASE NAME: CASE NO: PROJECT LOCATION: MITIGATED NEGATIVE DECLARATION Muroya Subdivision GPA 06-09/ZC 06-08/SP 203(D)/LCPA 06-09/CT 06-27/CP 06-19/CDP 06- 32/HDP 06-10/HMPP 07-02 North of Aviara Parkway, south of Corte Orchidia. east of Towhee Lane, and west of Black Rail Road. PROJECT DESCRIPTION: The proposed project involves a General Plan Amendment (GPA), Zone Change (ZC), Local Coastal Program Amendment (LCPA), Specific Plan Amendment (SPA), Tentative Tract Map (CT), Condominium Permit (CP), Coastal Development Permit (CDP), Hillside Development Permit (HDP), Habitat Management Plan Permit (HMPP) to allow for the subdivision and development of a 20.27 acre parcel (APN 215-040-03) located north of Aviara Parkway, south of Corte Orchidia, east of Towhee Lane, and west of Black Rail Road. The Parcel will be subdivided into five (5) separate lots. Lot 1 is approximately 6.3 acres in size and will contain 37 detached condominium units clustered in the northern and eastern portions of the lot. Lot 2 is 0.9 acres in size and is the site of the owners existing residence which will remain on this parcel. Lot 3 and 4 are 1.6 acres and 9.8 acres in size and will be open space lots (lot 3 as a buffer zone and lot 4 as open space habitat). Lot 5 is a 0.7 acre size lot which will be developed as private road for common access to the 3 7 detached condominium units. The current General Plan and Local Coastal Program Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with the Local Coastal Program and Zoning classification as L-C (Limited Control). The General Plan Amendment and LCPA will change the two (2) proposed open space lots 3 and 4 from RLM to OS (Open Space), the proposed residential lot land the proposed private street lot 5 from RLM to RM (Residential Medium Density, 4-8 dwelling units per acre), with lot 2 remaining RLM . Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots (3&4) will change from L-C to OS (Open Space), the zoning for the residential lots (1&5) will change from L-C to RD-M (Residential Density - Medium), and lot 2 will change from L-C to Single Family Residential (R-1). DETERMINATION: The City of Carlsbad has conducted an environmental review ofthe above described project pursuant to the Guidelines for Implementation of the California Environmental Quality Act and the Environmental Protection Ordinance of the City of Carlsbad. As a result of said review, the initial study (EIA Part 2) identified potentially significant effects on the environment, and the City of Carlsbad finds as follows: Although the proposed project could have a significant effect on the environment, there will not be a significant effect in this case because the mitigation measures described on the attached sheet have been added to the project. A copy of the initial study (EIA Part 2) documenting reasons to support the Mitigated Negative Declaration is on file in the Planning Department, 1635 Faraday Avenue, Carlsbad, California 92008. ADOPTED: DONNEU City Planner June 29, 2010. pursuant to City Council Resolution No. 2010-163 ~~·~----------------------------------------------------------------·": · 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T (760) 602-4600 F (760) 602-8559 ® r State of California-The Resources ~cy DEPARTMENT OF FISH AND GAME 2010 ENVIRONMENTAL FILING FEE CASH RECEIPT SEE INSTRUCTIONS ON REVERSE. TYPE OR PRINT CLEARLY LEAD AGENCY CITY OF CARLSBAD COUNTY/STATEAGENCY OF FILING SAN DIEGO PROJECT TITLE MUROYA SUBDIVISION PROJECT APPLICANT NAME TAYLOR MORRISON OF CA, LLC PROJECT APPLICANT ADDRESS 15 CUSHING STREET PROJECT APPLICANT (Check appropriate box): 0 Local Public Agency 0 School District CHECK APPLICABLE FEES: 0 Environmental Impact Report IZl Negative Declaration CITY IRVINE 0 Other Special District 0 Application Fee Water Diversion (State Water Resources Control Board Only) 0 Projects Subject to Certified Regulatory Programs 1Zl County Administrative Fee 0 Project that is exempt from fees 0 Notice of Exemption 0 DFG No Effect Determination (Form Attached) [] Other __________________________________ ___ PAYMENT METHOD: 0 Cash 0 Credit 1ZJ Check 0 Other_1_3_9_75 ___ _ SIGNATURE X 0 RECEIPT# SD2010 0641 STATE CLEARING HOUSE# (ttappticabteJ 2010021061 STATE CA 0 State Agency $2,792.25 $2,010.25 $850.00 $949.50 $50.00 $ $ $ $ $ DATE 07-08-2010 DOCUMENT NUMBER *20100173* PHONE NUMBER 858-864-6206 ZIP CODE 92618 0 Private Entity $2,010.25 $50.00 $ ______ _ TOTALRECEIVED $ ____ $2_:.,_06_0_.2_5_ I IIIII I IIIII IIIII IIIII 1111111111 IIIII IIIII 1111 1111 ORIGINAL-PROJECT APPLICANT COPY· DFG/ASB COPY-LEAD AGENCY COPY-COUNTY CLERK FG 753.5a (Rev. 7/08) Notice of Completion & Environmental Document Transmittal Mail to: State Clearinghouse, P. 0. Box 3044, Sacramento, CA 95812-(916) 445-0613 See NOTE Below: Project Title: MUROY A SUBDIVISION -GPA 06-09/ ZC 06-08/LCP A 06-09/SP 203D/CT 06-27 CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 SCH # ------Lead Agency: CITY OF CARLSBAD Contact Person: ~D""an!.!.;.H.,a""'lv'-"e:.!..!rs~o""'n _____ _ Street Address: 1635 FARADAY AVENUE County: SAN DIEGO COUNTY Phone:(760)602-4631 City: CARLSBAD Zip: 92008 PROJECT LOCATION~ County: San Diego City/Nearest Community: ___:C~ar'-!!ls~b~a~d ________________________ _ Cross Streets: West of Black Rail Road-North of Aviara Parkway Total Acres: 20.27 Zip Code: 92008 Assessor's Parcel No. 215-040-03 Within 2 Miles: State Hwy #: _5_ Waterways: ---'B~at~iq'i.!u~it~o~s2oL~a~g"""oo""n!"'--'P-"a"'c"'"'ifi"'Ic::...;O=ce,_,a'-!!n'------------------ Airports: McCLELLAN/PALOMAR Railways: NCTD Schools: Aviara Elementary and Middle School DOCUMENT TYPE: CEQA: 0 NOP 0 Early Cons I:8'J Neg Dec 0 Draft EIR LOCAL ACTION TYPE: 0 General Plan Update I:8'J General Plan Amendment 0 General Plan Element 0 Community Plan DEVELOPMENT TYPE: I:8'J Residential: UnitsJ]_ 0 Office: Sq. Ft. 0 Commercial: Sq. Ft. 0 Industrial: Sq. Ft. 0 Educational: 0 Recreational: 0 D D Supplement/Subsequent EIR (Prior SCH No.) Other: 0 Specific Plan 0 Master Plan I:8'J Planned Unit Development [8J Site Plan Acres 20.27 Acres Employees Acres Employees Acres Employees PROJECT ISSUES DISCUSSED IN DOCUMENT: 0 AestheticNisual 0 Flood Plain/Flooding 0 Agricultural Land 0 Forest Land/Fire Hazard D Air Quality 0 Geological/Seismic I:8'J Archaeological/Historical 0 Minerals D Coastal Zone I:8'J Noise D Drainage/ Absorption 0 Population/Hsg. Balance D Economic/Jobs 0 Public Services/Facilities D Fiscal 0 Recreation/Parks Present Land Use/Zoning/General Plan Use NEPA: 0 NOI OTHER: 0 Joint Document 0 0 D 0 D D I:8'J I:8'J D EA D Draft EIS D FONSI I:8'J Rezone D Prezone 0 Use Permit I:8'J Land Division (Subdivision, Parcel Map, Tract Map, etc.) 0 Water Facilities: 0 Transportation: 0 Mining: 0 Power: 0 Waste Treatment: 0 Hazardous Water: 0 Other: Schools/Universities Septic Systems Sewer Capacity D Final Document D Other: D Annexation D Redevelopment I:8'J Coastal Permit I:8'J Other: LCP A Amendment/ Hillside Development Permit/ Habitat Management Plan Permit Type MGD Type Mineral Type Watts Type Type 0 Water Quality D H20 Supply/Ground H20 D Wetland/Riparian Soil Erosion/Compaction/Grading I:8'J Wildlife Solid Waste 0 Growth Inducing Toxic/Hazardous D Land Use Traffic/Circulation I:8'J Cumulative Effect Vegetation D Other: Single Family House and Agricultural Use/ Limited Control (L-C)/ Residential Low-Medium Density (0-4 DUlAC) Project Description: The proposed project involves a General Plan Amendment (GPA), Zone Change (ZC), Local Coastal Program Amendment (LCPA), Specific Plan Amendment (SPA), Tentative Tract Map (CT), Condominium Permit (CP), Coastal Development Permit (CDP), Hillside Development Permit (HDP), Habitat Management Plan Permit (HMPP) to allow for the subdivision and development of a 20.27 acre parcel (APN 215-040-03) located north of Aviara Parkway, south of Corte Orchidia, east of Towee Lane, and west of NOTE: Clearinghouse will assign identification numbers for all new projects. If a SCH number already exists for a project (e.g. from a Notice of Preparation or previous draft document) please fill it in. January 2008 Black Rail Road. The Parcel will be subdivided into five (5) separate lots. Lot 1 is approximately 6.3 acres in size and will contain 37 detached condominium units clustered in the northern and eastern portions ofthe lot. Lot 2 is 0.9 acres in size and is the site of the owners existing residence which will remain on this parcel. Lot 3 and 4 are 1.6 acres and 9.8 acres in size and will be open space Jots (lot 3 as a buffer zone and Jot 4 as open space habitat). Lot 5 is a 0.7 acre size Jot which will be developed as private road for common access to the 3 7 detached condominium units. The current General Plan and Local Coastal Program Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with the Local Coastal Program and Zoning classification as L-C (Limited Control). The General Plan Amendment and LCPA will change the two (2) proposed open space lots 3 and 4 from RLM to OS (Open Space), the proposed residential lot land the proposed private street lot 5 from RLM to RM (Residential Medium Density, 4-8 dwelling units per acre), with lot 2 remaining RLM . Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space Jots (3&4) will change from L-C to OS (Open Space), the zoning for the residential lots (1&5) will change from L-C to RD-M (Residential Density-Medium), and lot 2 will change from L-C to Single Family Residential (R-1 ). The site currently has a single-family structure in the southeast comer of the Jot, while the north and northeast section of the lot is presently used for agricultural production. The southwest section of the lot is predominantly occupied by natural vegetated hillsides and canyons. Topographically, the site slopes downhill from east to west. The northeast section, the agricultural section, is a flat pad and then slopes steeply down to the south and west property lines. A 150-ft wide SDG&E easement bisects the site diagonally in a northwest/southeast direction. Surrounding land uses include single-family residential to the north on Courte Orchidia, open space and single-family residential to the south, single-family and vacant Jots to the east across Black Rail Road, and single-family homes to the west off To wee Lane. \ \ . j _) Reviewing Agencies Checklist Resources Agency __ Boating & Waterways _S_Coastal Commission __ Coastal Conservancy __ Colorado River Board __ Conservation, Dept. of _S_Fish & Game __ Forestry & Fire Protection __ Office of Historic Preservation __ Parks & Recreation __ Reclamation Board __ S.F. Bay Conservation & Development Commission __ Water Resources (DWR) Business, Transportation & Housing __ Aeronautics __ California Highway Patrol __ CAL TRANS District# ____ _ __ Department of Transportation Planning (headquarters) __ Housing & Community Development __ Food & Agriculture Health & Welfare __ Health Services __________ _ State & Consumer Services __ General Services __ OLA (Schools) Public Review Period (to be filled in by lead agency) Smrting ~February :r: S1gnatur~~ U Lead Agency (Complete if applicable): Consulting Firm: _______________ _ Address: __________________ _ City/State/Zip: ----------------- Contact: __________________ _ Phone:L__j ------------------------------ Applicant: __ ---'T~a:!,!y...!.Cio~r'-'M~oe!..!rre!.!is""'o""n'-'o""'f""'C""A~.,--"L~L,_,C~ ___ _ Address: 15 Cushing Street City/State/Zip: Irvine CA 92618 Phone: (858) 864-6206 Form A, continued KEY S = Document sent by lead agency X = Document sent by SCH ~= Suggested distribution Environmental Protection Agency ____ Air Resources Board ____ California Waste Management Board ____ SWRCB: Clean Water Grants ___ SWRCB: Delta Unit ___ ,SWRCB: Water Quality ___ SWRCB: Water Rights ___ Regional WQCB # __ _ Youth & Adult Corrections ___ Corrections Independent Commissions & Offices ____ Energy Commission __ __ Native American Heritage Commission ___ Public Utilities Commission ___ Santa Monica Mountains Conservancy ___ State Lands Commission ___ Tahoe Regional Planning Agency ___ S_Other US Fish & Wildlife Service Ending Date _ ___,M~ar=ch~l9~2'-"0...!.l""-O------------ Date ____ d.=-+{_Lt~l~/~----'t_,t..:>=------------ For SCH Use Only: Date Received at SCH Date Review Starts: Date to Agencies Date to SCH Clearance Date Notes: NOTE: Clearinghouse will assign identification numbers for all new projects. If a SCH number already exists for a project (e.g. from a Notice of Preparation or previous draft document) please fill it in. January 2008 SITE MAP • N NOT TO SCALE Muroya Subdivision GPA 06-09 I ZC 06-08 I SP 2030 I LCPA 06-09 I CT 06-27 I CP 06-19 I COP 06-321 HOP 06-10 I HMPP 07-02 CASE NAME: CASE NO: PROJECT LOCATION: City of Carlsbad *i·i··'··"'·I'N•*M4t·i·i··'4·'' NOTICE OF INTENT TO ADOPT A MITIGATED NEGATIVE DECLARATION Muroya Subdivision GPA 06-09/ZC 06-08/LCPA 06-09/SP 2030/CT 06-27/CP 06-19/CDP 06-32/HDP 06-1 0/HMPP 07-02 North of A viara Parkway, south of Corte Orchidia, east of To wee Lane, and west of Black Rail Road CAPN 215-040-03). PROJECT DESCRIPTION: The proposed project involves a General Plan Amendment (GPA), Zone Change (ZC), Local Coastal Program Amendment (LCPA), Specific Plan Amendment (SPA), Tentative Tract Map (CT), Condominium Permit (CP), Coastal Development Permit (COP), Hillside Development Permit (HOP), Habitat Management Plan Permit (HMPP) to allow for the subdivision and development of a 20.27 acre parcel (APN 215- 040-03) located north of Aviara Parkway, south of Corte Orchidia, east ofTowee Lane, and west ofBlack Rail Road. The Parcel will be subdivided into five (5) separate lots. Lot 1 is approximately 6.3 acres in size and will contain 37 detached condominium units clustered in the northern and eastern portions of the lot. Lot 2 is 0.9 acres in size and is the site of the owners existing residence which will remain on this parcel. Lot 3 and 4 are 1.6 acres and 9.8 acres in size and will be open space lots (lot 3 as a buffer zone and lot 4 as open space habitat). Lot 5 is a 0. 7 acre size lot which will be developed as private road for common access to the 37 detached condominium units. The current General Plan and Local Coastal Program Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with the Local Coastal Program and Zoning classification as L-C (Limited Control). The General Plan Amendment and LCPA will change the two (2) proposed open space lots 3 and 4 from RLM to OS (Open Space), the proposed residential lot land the proposed private street lot 5 from RLM to RM (Residential Medium Density, 4-8 dwelling units per acre), with lot 2 remaining RLM. Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots (3&4) will change from L-C to OS (Open Space), the zoning for the residential lots (1&5) will change from L-C to RO-M (Residential Density-Medium), and lot 2 will change from L-C to Single Family Residential (R-1 ). PROPOSED DETERMINATION: The City of Carlsbad has conducted an environmental review of the above described project pursuant to the Guidelines for Implementation of the California Environmental Quality Act (CEQA) and the Environmental Protection Ordinance of the City of Carlsbad. As a result of said review, the initial study (EIA Part 2) identified potentially significant effects on the environment, but (1) revisions in the project plans or proposals made by, or agreed to by, the applicant before the proposed negative declaration and initial study are released for public review would avoid the effects or mitigate the effects to a point where clearly no significant effect on the environment would occur, and (2) there is no substantial evidence in light of the whole record before the City that the project "as revised" may have a significant effect on the environment. Therefore, a Mitigated Negative Declaration will be recommended for adoption by the City of Carlsbad City Council. A copy of the initial study (EIA Part 2) documenting reasons to support the proposed Mitigated Negative Declaration is on file in the Planning Department, 1635 Faraday Avenue, Carlsbad, California 92008. Comments from the public are invited. Pursuant to Section 15204 of the CEQA Guidelines, in reviewing Mitigated Negative Declarations, persons and public agencies should focus on the proposed finding that the project will not have a significant effect on the environment. If persons and public agencies believe that the project may have a significant effect, they should: (1) identify the specific effect; (2) explain why they believe the effect would occur; and (3) explain why they believe the effect would be significant. Please submit comments in writing to the Planning Department within 30 days of the date of this notice. The proposed project and Mitigated Negative Declaration are subject to review and approval/adoption by the City of Carlsbad Planning Commission and City Council. Additional public notices will be issued when those public hearings are scheduled. If you have any questions, please call Dan Halverson in the Planning Department at (760) 602-4631. PUBLIC REVIEW PERIOD: PUBLISH DATE: February 17, 20 I 0-March 19, 20 I 0 February 17, 2010 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2710 • FAX (760) 602-8560 <!) c STATE OF CALIFORNIA GOVERNOR'S OFFICE of PLANNING AND RESEARCH STATE CLEARINGHOUSE AND PLANNING UNIT ARNOLDSCHWARZENEGGER GOVERNOR March 24,2010 Dan Halverson City of Carlsbad Planning Department 1635 Faraday Avenue Carlsbad, CA 92008 Subject: Muroya Subdivision -GPA 06-09 I ZC 06-08/LCPA 06-09/SP 203D/CT 06-27 SCH#: 2010021061 Dear Dan Halverson: CYNTHIA. BRYANT DIRECTOR CITY OF CARLSBAD MAR 2 9 1010 Community & Economic Devek>pment Department The State Clearinghouse submitted the above named Negative Declaration to selected state agencies for review. On the enclosed Document Details Report please note that the Clearinghouse has listed the state agencies that reviewed your document. The review period closed on March 23,2010, and the comments from the responding agency (ies) is (are) enclosed. If this comment package is not in order, please notify the State Clearinghouse immediately. Please refer to the project's ten-digit State Clearinghouse number in future correspondence so that we may respond promptly. Please note that Section 21104(c) of the California Public Resources Code states that: "A responsible or other public agency shall only make substantive comments regarding those activities involved in a project which are within an area of expertise of the agency or which are required to be carried out or approved by the agency. Those comments shall be supported by specific documentation." These comments are forwarded for use in preparing your fmal environmental document. Should you need more information or clarification of the enclosed comments, we recommend that you contact the commenting agency directly. This letter acknowledges that you have complied with the State Clearinghouse review requirements for draft environmental documents, pursuant to the California Environmental Quality Act. Please contact the State Clearinghouse at (916) 445-0613 ifyou have any questions regarding the environmental review process. ~~ Acting Director, State Clearinghouse Enclosures cc: Resources Agency 1400 lOth Street P.O. Box 3044 Sacramento, California 95812-3044 (916) 445-0613 FAX (916) 323-3018 www.opr.ca.gov c Document Details Report State Clearinghouse Data BaseQ SCH# 201 0021061 Project Title Muroya Subdivision -GPA 06-09 I ZC 06-08/LCPA 06-09/SP 2030/CT 06-27 Lead Agency Carlsbad, City of Type Neg Negative Declaration Description The proposed project involves a General Plan Amendment (GPA), Zone Change (ZC), Local Coastal Program Amendment (LCPA), Specific Plan Amendment (SPA), Tentative Tract Map (CT), Condominium Permit (CP), Coastal Development Permit (COP), Hillside Development Permit (HOP), Habitat Management Plan Permit (HMPP) to allow for the subdivision and development of a 20.27 acre parcel (APN 215-040-03) located north of Aviara Parkway, south of Corte Orchidia, east of Towee Lane, and west of Black Rail Road. The Parcel will be subdivided into 5 separate lots. Lot 1 is -6.3 acres in size and will contain 37 detached condominium units clustered in the northern and eastern portions of the lot. Lot 2 is 0.9 acres in size and is the site of the owners existing residence which will remain on this parcel. Lot 3 and are 1.6 acres and 9.8 acres in size and will be open space lots (lot 3 as a buffer zone and lot 4 as open space habitat). Lot 5 is a 0.76 acre size lot which will be developed as private road for common access to the 37 detached condominium units. Lead Agency Contact Name Agency Phone email Address City Dan Halverson City of Carlsbad 760-602-4631 Planning Department 1635 Faraday Avenue Carlsbad Project Location County San Diego City Carlsbad Region Lat!Long Cross Streets West of Black Rail Road-North of Aviara Parkway 215-040-03 Fax State CA Zip 92008 Parcel No. Township Range Section Base Proximity to: Highways 5 Airports McClellan Palomar Railways NCTD Waterways Batiquitos Lagoon/Pacific Ocean Schools Aviar ES and MS Land Use Single Family House and Agricultural Use/Limited Control (L-C)/Residential Low-Medium Density (0-4 DUlAC) Project Issues Archaeologic-Historic; Cumulative Effects; Noise; Traffic/Circulation; Vegetation; Wildlife Reviewing Resources Agency; Department of Fish and Game, Region 5; Office of Historic Preservation; Agencies Department of Parks and Recreation; Department of Water Resources; Office of Emergency Management Agency, California; Caltrans, Division of Aeronautics; California Highway Patrol; Caltrans, District 11; Regional Water Quality Control Board, Region 9; Department of Toxic Substances Control; Native American Heritage Commission Date Received 02/22/2010 Start of Review 02/22/2010 End of Review 03/23/2010 Note: Blanks in data fields result from insufficient information provided by lead agency. c ENVIRONMENTAL IMPACT ASSESSMENT INFORMATION FORM (To be Completed by Applicant) Date Filed: ~C.. \;,1 ?..UOCo (To be completed by City) Application Number(s): Girts rio-CS!btPP.. Qb·di' u.. Dlo~oBI C.T ob.-ZJ I C..? Cb~\9 {c.or Ci?-~ HPP Ol::.-ID I I t I General Information I. Name of project: Muroya Property --~--~~----------------------------------------------- 2. Name of developer or project sponsor: Taylor Woodrow Homes, Inc. -------------------------------------------- Address: 167 45 W. Bernardo Drive, Ste 140 City, State, Zip Code: San Diego, CA 92127 ------------------------------------------------------ Phone Number: (858) 943-51 00 ---------------------------------------------------------- 3. Name of person to be contacted concerning this project: April Tornillo --------------------------------- Address: 167 45 W. Bernardo Drive, Ste 140 City, State, Zip Code: San Diego, CA 92127 ----~------------------------------------------------ Phone Number: (858) 943-5100 ---------------------------------------------------------- 4. Address of Project: None Assigned -------------------------------------------------------- Assessor's Parcel Number: 215-040-03 5. List and describe any other related permits and other public approvals required for this project, including those required by city, regional, state and federal agencies: Tentative Ma~ Condominium Permit, Coastal Develoament Permit, Hillside Development Permit, General Plan Amendment, one Change, Local Coastal Plan Amen ment 6. Existing General Plan Land Use Designation: R....,.e""si ..... de ..... n .... tj...,ai_..L,.,ow~-..... Mu.e:.udi.ld.!um.l..!.-l.JIR..u.L.uM.J.J,..\ ____________________ _ 7. Existing zoning district: ...l:L..,_,_im!.:.!.it~e~d-~C~on~tr~o.l..,;l (u.L...::-C~l ---------------------------------------- 8. Existing land use(s): Single Family Residence and palm tree nursery 9. Proposed use of site (Project for which this form is filed): Residential subdivision for 37 detached condominium units. Project Description 10. Site size: 20.27 acres ~~~~------------------------------------------------------- II. Proposed Building square footage: 102,677 sq. ft. total ---------------------------------------------- 2 02/22/06 12: Number of floors of construction: Proposed structures are 1-story and 2-story buildings 13. Amount of off-street parking provided: 84 --------------------------------------------- 14. Associated projects: N/A ---------------------------------------------------- 15. If residential, include the number of units and schedule of unit sizes: The proposal includes 4 plan types. Plan 1 is 2,228 sq.ft. and is plotted 6 times. Plan 2 is 2,068 sq. ft. and is plotted 15 times. Plan 3 is 2,495 sq. ft. and is plotted 9 times. Plan 4 is 2,827 sq. ft. and is plotted 7 times within the project. 16. If commercial, indicate the type, whether neighborhood, city or regionally oriented, square footage of sales area, and loading facilities: · __ N/_A ____________________________________ _ 17. If industrial, indicate type, estimated employment per shift, and loading facilities: _N_IA ______ _ 18. If institutional, indicate the major function, estimated employment per shift, estimated occupancy, loading facilities, and community benefits to be derived from the project: N/A --------------------------- 19. If the project involves a variance, conditional use or rezoning applications, state this and indicate clearly why the application is required: General Plan amendment is required per the City's HMP for the designation of the open space as OS and the remainder of the property has RM for land use consistency. The current zoning is L -C which is only for aaricultural uses. The Zone Chanae aoolication is to chanae the existina zonina to RO-M that implements the RM land use Are the following items applicable to the project or its effects? Discuss all items checked yes (attach additional sheets as necessary). 20. Change in existing features of any bays, tidelands, beaches, or hills, or substantial alteration of ground contours. 21. Change in scenic views or vistas from existing residential areas or public lands or roads. 22. Change in pattern, scale or character of general area of project. 23. Significant amounts of solid waste or litter. 24. Change in dust, ash, smoke, fumes or odors in vicinity. 3 Yes w w r r r No r r w w w 02/22/06 25. 26. 27. 28. 29. 30. 31. 0 0 Yes Change in ocean, bay, lake, stream or ground water quality or quantity, or r alteration of existing drainage patterns. Substantial change in existing noise or vibration levels in the vicinity. r Site on filled land or on slope of I 0 percent or more. p Use of disposal of potentially hazardous materials, such as toxic I substances, flammables or explosives. Substantial change in demand for municipal services (police, fire, water, I sewage, etc.). Substantially increase fossil fuel consumption (electricity, oil, natural gas, I etc.). Relationship to a larger project or series of proJects. ~ Environmental Setting Attach sheets that include a response to the following questions: No p w r r 32. Describe the project site as it exists before the project, including information on topography, soil stability, plants and animals, and any cultural, historical or scenic aspects. Describe any existing structures on the site, and the use of the structures. Attach photographs of the site. Snapshots or Polaroid photos will be accepted. 33. Describe the surrounding properties, including information on plants and animals and any cultural, historical or scenic aspects. Indicate the type of land use (residential, commercial, etc.), intensity of land use (one-family, apartment houses, shops, department stores, etc.), and scale of development (height, frontage, set-back, rear yard, etc.). Attach photographs of the vicinity. Snapshots or polaroid photos will be accepted. Certification I hereby certify that the statements furnished above and in the attached exhibits present the data and information required for this initial evaluation to the best of my ability, and that the facts, statements, and information presented are true and correct to the best of my knowledge and belief. Date: /Z-t/-exo Signature: For: 4 02/22/06 0 SUPPLEMENTAL TO THE ENVIRONMENTAL IMPACT ASSESSMENT INFORMATION FORM ENVIRONMENTAL SETTING The subject property includes an active palm tree nursery and an existing single family residence · located in the southeastern portion of the property that is occupied by the Muroya family. The nursery operation includes shade houses, equipment sheds and associated access roads. A 150, foot wide easement for SDG&E transmission lines extends through the central portion of the property. The remaining property is undeveloped and covered with native vegetation. Topographically, the eastern and northern portions of the site, where the existing residence and nursery are located, generally consist of a relatively level to gently sloping mesa. The property in these areas has a total elevation drop of approximately twenty (20) feet from Black Rail Road to the west. The western and southern portions of the property consists of moderately to steeply inclined natural and fill slopes extending from the SDG&E easement south and west into a large canyon. The elevation differential in these areas is approximately eighty (80) feet from east to west. Soil conditions on the site include surficial soil consisting of debris fill, undocumented fill, topsoil, colluviums, alluvium and formation materials of the Lindavista and Santiago Formations. Pursuant to the enclosed preliminary geotechnical investigation, the site contains no soil or geologic condition that would adversely impact the proposed development as long as the recommendations contained within the report are incorporated. As mentioned above, the subject property includes a palm tree nursery, a single family residence with the remainder of the property undeveloped and dominated by natural vegetation. Per the enclosed biological report, there are nine plant communities that were identified on the subject site. They include southern maritime chaparral, coastal sage scrub, southern mixed chaparral, baccharis scrub, developed land, grassland, ornamental plantings, disturbed habitat and agricultural lands. No plant species listed as rare, threatened or endangered by the state or federal government agencies were detected on the property. Three special,status plant species were observed on the site within the natural vegetated areas. These include the Nuttall's scrub oak, wart stemmed ceanothus and the Engelmann oak. In addition, the California gnatcatcher was documented to be on the property and is a federally,listed threatened species. Cultural resources on the subject property include one documented site that was listed as insignificant within the Zone 20 Final Program Environmental Impact Report and an additional isolated cultural resource identified during a pedestrian survey by the applicant's archaeologist. As a result a detailed Phase I Cultural Resources Assessment of the property is currently being prepared and will be submitted to the City as soon as the report is completed. A paleontological review of the subject property was conducted and found that the sedimentary rocks mapped in the vicinity of the site have moderate to high Paleontological sensitivity. The soil types within the property contain the same type of sedimentary rock and have the potential to contain paleontological resources. JACK HENTHORN & ASSOCIATES Muroya-Supplemental EIA . ~ . . 0 SUPPLEMENTAL TO THE 0 ENVIRONMENTAL IMPACT ASSESSMENT INFORMATION FORM The topography of the surrounding area is approximately 330 to 360 feet above mean sea level (MSL). Given the location and elevation of the property, there are scenic views to the west from internal viewpoints of the site as well as from the surrounding developed properties through and over the property. The subject site is surrounded by existing residential development on all four sides. The developments to the west and south of the subject property are within the Aviara Master Plan. The development to the west is a detached single~family neighborhood having lot sizes that range in size from 7,500 to 10,000 square feet. The development to the south is a condominium development located on both sides of Black Rail Road. The residential development to the north contains thirty~two (32) existing detached single family homes on minimum 10,000 square foot lots. The residential developments to the east across Black Rail Road are in different stages of the development process. Some units are constructed and currently occupied, another property is currently graded and the southern most property has an active application in the City for residential development. All of the properties to the east are small~ lot developments with minimum lot sizes of 5,000 square feet. PROJECT DESCRIPTION The applicant is proposing thirty~seven (37) detached condominium units on a five (5) lot residential subdivision on the Muroya property located within the Zone 20 Specific Plan area. The proposed project has been designed to cluster the development in the areas of the site that have been previously disturbed by the palm tree nursery operation. This results in a significant portion of the property covered by native vegetation being left undisturbed. The subject project does propose grading that will alter the existing topography. However, the proposed grading will maintain the overall contours of the existing property by stepping the proposed pad grades progressively down to the west. The project does propose a balance between cut and fill grading quantities once the spoils from utility and foundation trenching are calculated into the cut and fill numbers. With the proposed grading of the site and construction of the future residential units, there will be a change in scenic views from the site as well as from the surrounding existing residential developments. In the preparation of the enclosed plans, the applicant and their consultants made the utmost effort to address the potential impacts to the scenic views to the west. The proposed architecture for the project includes single~story elements that were situated along the northern boundary to provide some view corridors. The site plan also lowers the proposed pad heights as much as possible while maintaining a balanced grading operation as mentioned above. As mentioned above, the subject property is located within the boundaries of the Zone 20 SpeCific Plan area that designated the site for residential development. The Zone 20 Specific Plan provided the framework for the future development of the properties within Zone 20 that ensured the most logical and efficient provision of public facilities and community amenities for JACK HENTHORN & ASSOCIATES Muroya-Supplemental EIA 2 ... ' " c SUPPLEMENTAL TO THE ENVIRONMENTAL IMPACT ASSESSMENT INFORMATION FORM the future residents of the area. All of the surrounding properties have been previously developed or are currently under review with the City per the provisions of the either the Zone 20 Specific Plan or the adjacent Aviara Master Plan. The subject property is one of the last properties in the southern portion of the specific plan area to develop. All impacts associated with the project can be mitigated to below a level of significance pursuant to the recommendations found within the enclosed technical reports. In lieu of these findings the applicant is requesting the processing of a mitigated negative declaration for the impacts associated with the proposed project. SOURCE DOCUMENTS The following documents were used in the analysis of this project and are enclosed as a part of the submittal for the Muroya property. 1. "Final Program Environmental Impact Report for Zone 20 Specific Plan" and Planning Commission Resolution 3525 for EIR 203 dated June 16, 1993. 2. "Preliminary Geotechnical Investigation, Muroya Property, Carlsbad, California" dated April, 2006, prepared by Geocon, Inc. 3. "Tentative Map Drainage for Muroya, City of Carlsbad, California" dated November 30, 2006 prepared by Hunsaker & Associates, San Diego, Inc. 4. "Biological Resources Technical Report and Impact Analysis for the Muroya Property, City of Carlsbad, California" dated December 2006, prepared by Dudek, Anita M. Hayworth, Ph.D., Senior Biologist. 5. "Summary of Cultural and Paleontological Resource Findings for Taylor Woodrow, Inc., Muroya Project in the City of Carlsbad, San Diego County, California" dated December 11, 2006, prepared by Michael Brandman Associates, Jennifer M. Sanka, M.A., Staff Archaeologist. JACK HENTHORN & ASSOCIATES Muroya-Supplemental EIA 3 (t't C I TY O F ~~~ CARLSBAD Memorandum July 26, 2011 To: From: Re: John Kim, Traffic Engineering Division Mike Peterson, Development Services Manager Nick Roque, Transportation -Streets Lori Allen, Police Department GIS Department Greg Ryan, Fire Department Glen Van Peski, Land Use Engineering Chris Sexton, Planning Technician STREET NAMES FOR CT 06-27 -MUROYA SUBDIVISION FiLE COF'l The following street names have been approved as a part of the final map processing for CT 06-27 - MUROYA SUBDIVISION. A map delineating street locations is attached. Private Streets: White Sage Way Hollyleaf Court Sweetclover Lane As much as you are able, please make sure approved street names are shown and spelled correctly on all final map and construction drawings. Attachment c: Dan Halverson, Project Planner Clyde Wickham, Project Engineer Mario Remillard, Maintenance & Operations Community & Economic Development 1635 Faraday Ave. I Carlsbad, CA 92008 I 760-602-2710 I 760-602-8560 fax DATE: TO: FROM: CITY OF CARLSBAD REQUEST FOR CONDITIONS JANUARY 19. 2010 FINAL REVISED PLANS INCLUDED [SI [g] ENGINEERING, DEVELOPMENT SERVICES -TERIE ROWLEY 0 POLICE DEPARTMENT-J. SASWAY [g] FIRE DEPARTMENT-JIM WEIGAND 0 BUILDING DEPARTMENT-WILL FOSS 0 RECREATION -MARK STEYAERT [g] LANDSCAPE PLANCHECK CONSULTANT-PELA 0 PARKS/TRAILS-LIZ KETABIAN 0 M & 0-CMWD -STEVE PLYLER *ALWAYS SEND EXHIBITS PLANNING DEPARTMENT REQUEST FOR CONDITIONS ON PROJECT NO(S): GPA 06-09/ZC 06-08/SP 203D/ LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMP 07-02 PROJECTTITLE~:M==ur=o~va~----------------------------------------­ APPLICANT: Jack Henthorn & Associates ------------------------------- PROPOSAL: 37 detached condo units. Please review and submit written conditions to MICHELE MASTERSON in the Planning Department at 1635 Faraday Avenue, by If you have "No Conditions", please so state. If you have any questions, please contact Dan Halverson at ext. 4631 . THANK YOU COMMENTS: ________________________________________________ _ c: File Request for Conditions 9/08 Memorandmn TO: Jason Goff, Assistant Planner FROM: Clyde Wickham, Associate Engineer DATE: November 23, 2009 CT 06-27 I COP 06-321 CP 06-191 GPA 06-091 HOP 06-10 I HMP 07-021 LCPA 06-09 I ZC 06-08 I SP 203-D --MUROYA RESIDENTIAL SUBDIVISION COMPLETENESS & ISSUES REVIEW Engineering Department staff has completed another review of the above-referenced project for application completeness. The application and plans submitted for this proposed project is considered complete with issues to be resolved prior to support of the application(s). The following issues need to be resolved prior to resubmittal: 1. The City has attached comments and corrections from Geotechnical third party review. Please correct and resubmit the geotechnical report, or submit an addendum to address these comments. 2. The design speed for Street "A" is 25 mph. Please correct the profile design on sheet 4. Show compliance with design requirements identified in chapter 3 and 4 of the City's Engineering Standards. 3. The proposed Stormfilter unit and filter inserts shown on sheet 3 and sheet 5 is acceptable as a filtration unit for the anticipated development of the north half of this project. The southern portion of the project has no structural filtration device as identified on sheet 3, please revise. 4. The project is a Priority Project and must incorporate Low Impact Design (LID) features per Engineering Standards Volume 4, Section 2.3.3.1 and Appendix B. This will be a condition of approval that could require redesign or modification. If you have any questions please contact let me at (760) 602-27 42 or email at Clyde.Wickham@carlsbadca.gov Mr. Clyde Wickham City of Carlsbad 1635 Faraday Avenue Carlsbad, California 92008 Subject: Geotechnical Peer Review Proposed Muroya Residential Subdivision Carlsbad Tract 06-27 Carlsbad, California Dear Mr. Wickham: November 11, 2009 Project No. 106560003 At your request and the authorization of the City of Carlsbad (the City), we have performed a third party (or peer) review of project geotechnical docum~nts for the proposed Muroya Residenti~l Sub-. . . division, Carlsbad Tract 06-27; The subject tract is located along the west side of Black Rail Road across from Songbird and Ocean Crest Avenues in Carlsbad, California. Reviewed documents pro- vided by the City included: the project geotechnical report (Geocon, 2009a); a response to review comments letter (Geocon, 2009b ); and, a review memorandum prepared by the City. Our general scope of services was to review the materials provided and check them for compliance with mini- mum code standards, completeness, factual errors, consistency of data with the conclusions offered, and conformance to the standards of geotechnical practice. A list of reviewed references is appended. SCOPE OF SERVICES Our specific scope of services included the following: • Review of the referenced project geotechnical documents provided by the City of Carlsbad. • Review of available published geologic and geotechnical maps and reports pertinent to the site arei • Reconnaissance of the site by a Certified Engineering Geologist from our office. • Preparation of this letter presenting the findings of our peer review. REVIEW COMMENTS From our review of the provided documents, we have developed the following review comments: 57 1 0 Ruffin Road • San Diego. California 92123 • Phone (858! 576-1000 • Fax {858) 576-9600 San D1ego • INine • Rancho Cucamonga • Los Angeles • Oakland • Las Vegas • Phoenix • Denver • B Paso Proposed Muroya Residential Subdivision, Carlsbad Tract 06-27 Carlsbad, California November 11, 2009 Project No. 106560003 • There are minor deficiencies on the cross sections. These include mislabeling T-10 as T-4 on Cross Section A-A', not showing T-4 and T-5 on Cross Section B-B', and (also on B-B') not showing the seepage. • The logs for trenches T-3, T-4, and T-5 indicate that the debris fill is in an "overall poor, uncom- pacted condition." However, Page 15 of the project geotechnical report recommends that surficial soils be considered as a Type B soil classification for temporary excavations. Due to the poor condition of the debris fill, consideration should be given to classifying the debris fill as a Type C soil for temporary excavations. • Page 2 of the project geotechnical report concludes that the debris fill is "unsuitable for support of additional fill." However, Cross Section B-B' and Pages 7 and 12 ofthe report indicate that due to grading restraints for sensitive habitats, portions of the fill slope at the southeast portion ofthe site will be supported on debris fill. Due to the potential instability ofthe underlying de- bris fill, consideration_ should be given to provide additional grad~ng recommendations in this area of the project. • The log for trench T-4 indicates that alluvial materials may exist to depths greater than 7'h. feet. Based on the recommendations on Page 8 of the project geotechnical report, the existing allu- vium should be removed and recompacted. Based on the anticipated depths ofthe recommended removals at the location of trench T-8, the horizontal limits of temporary excavations rriay be limited due to the adjacent Nightshade Road. Consideration should be given to provide tempo- rary shoring recommendations for this area. • The report does not provide a recommendation for the construction of a backdrain within the keyway for the 1.5:1 slope at the western portion of the project. Consideration should be given to provide such a recommendation. • Seepage was encountered within trench T-4. This seepage was not depicted on Cross Section B-B' or discussed as part of the slope stability analysis presented on Figure 5 of the report. We appreciate the opportunity to be of service on this project. Respectfully submitted, NINYO & MOORE ~~:::GE. Senior Project Engineer JTKIRI/kh Attachment: References Distribution: ( 1) Addressee I 06560003 L.doc 2 ~r~ Chief Engineering Geologist .. " Proposed Muroya Residential Subdivision, Carlsbad Tract 06-27 Carlsbad, California REFERENCES November 11, 2009 Project No. 106560003 American Society of Civil Engineers, 2005, ASCE Standard 7, Minimum Design Loads for Buildings and Other Structures. California Building Standards Commission (CBSC), 2007, California Building Code (CBC), Title 24, Part 2, Volumes 1 and 2. City of Carlsbad Engineering Development Services, 2009, CT 06-27/CDP 06-32/CP 06-19/GPA 06-09/HDP 06-1 0/LCPA 06-09/ZC 06-08, Muroya Residential Subdivision Completeness & Issues Review: dated September 8. Geocon, 2009a, Muroya Property, Carlsbad, California, Response to Review Comments, Project No. 07671-52-01: dated July 10. Geocon, 2009b, Geotechnical Investigation, Muroya Property, Carlsbad, California, Project No. 07671-52-01: dated-July 14. - Kennedy, M.P., 1996, Geologic Maps of the Northwestern Part of San Diego County, California: California Division of Mines and Geology, Open-File Report 96-02. Kennedy, M.P. and Tan, S.S., 2008, Geologic Map of the Oceanside 30' x 6Q' Quadrangle, California: California Geological Sur:vey, Regional Geologic.Map Series. · Tan, S.S. and Giffen, D.G, 1995, Landslide Hazards in the Northern Part of the San Diego Metro- politan Area, San Diego County, California, California Division of Mines and Geology: Landslide Hazards Identification Map No. 35, Open-File Report 95-04. 106560003 L.doc 1 of 1 CITY OF CARLSBAD REVIEW AND COMMENT MEMO NOVEMBER 12. 2009 Review #1 SP 203D Review #4 GPA 06-09, etal FROM: [gl Engineering, Development Services-Terie Rowley D Police Department-J. Sasway [gl Fire Department -James Weigand D Building Department-Will Foss D Recreation -Mark Steyaert D Public Works Department (streets)-Thomas Moore D Water/Sewer District [gl Landscape Plancheck Consultant -PELA D School District D North County Transit District -Planning Department D Sempra Energy - Land Management D Caltrans (Send anything adjacent to 1-5) D Parks/Trails -Liz Ketabian *ALWAYS SEND EXHIBITS PLANNING DEPARTMENT REQUEST FOR REVIEW AND COMMENT ON PROJECT NO(S): GPA 06-09/ZC 06- 08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMP 07-02 & SP 2030. APPLICANT: Jack Henthorn & Associates PROPOSAL: 37 detached condo units. Please review and submit written comments and/or conditions to Michele Masterson in the Planning Department at 1635 Faraday Avenue, by 12/01/09. If you have "No Comments," please so state. Thank you COMMENTS: __ ,Lh_-L...Jee~:::...-_./:~:.('-.::/9~7'~J::._-~/'J~o:::.__::C~~=-....:...·z...n--;,~-,=::;;;v;::_::....:..::..'KJ=------------ PLANS ATTACHED Review & Comment 09/07 ( HMP/MHCP Compliance Review Proposed Project: Muroya Property Date Received: Reviewed By: 9/09/09 Rosanne Humphrey Preserve Stevvard • For HMP compliance purposes, all vegetation categories should fit within the Holland classification system, or at least be identified as Habitat Group A-F (HMP Table 11). o "Baccharis scrub" should be identified as coastal sage scrub (Group D, if unoccupied by coastal California gnatcatcher) o "Leymus condensatus grassland" should be identified as "native grassland" (Group B). o "Ornamental plantings" are naturalized non-native species. There is no ideal Holland classification for this, but the closest would be "non-native grassland," (Group E) which tends to be a catch-all for areas dominated by non-native grasses and broadleaf plants. • There should be an exhibit showing an overlay of the property with Linkage F and surrounding Core Areas since this is specifically mentioned in the Standards for properties within LFM Zone 20. • Please change the date of gnatcatcher breeding season from March 1-August 15 to February 15-August 30 to conform to the dates listed in the USFWS survey protocol. • Section 6.0: Impacts to ornamental Plantings (changed to Non-native Grassland, as noted above) should be mitigated with an in-lieu fee. Please add this to Section 6. • ·Page 42, paragraph 3, add red text "A buffer zone of 500 feet will be established ... " • Page 42 paragraph 5, add red text "The open space area will need to be protected by a conservation easement, and a non-wasting endowment will need to be established for permanent management of the area." Landscape plans • Unless you can show that it's not invasive, please remove Pennisetum alopecuroides HMP/MHCP Compliance Review 1 HMP Compliance Review Routing Sheet Project Name/Number: Requested By (Planner): Authorized By (Supervisor): Type of Review*: Date Received: *Project review for HMP compliance, biological technical report assistance, response to public comments, other. Description of attachments: -~io hz.~n:c.c~ ~ : J::>v-~'<.... JcA \ '1 , ~C) -5rk. PI~ Co.r ~4c. j..... ;-~' ...fko_ ~.., C-~ ~ ~(.;Je.. f'Ac..{J (c..r'r..~: I ? ,.,. "''<> ",) Le7....r-hc.~p e.... ( O,f\. c..C-f* (>1,..,. :> ) The above items are submitted: D For your approval/action D For your information/files Instructions • On the document, number the comments you want addressed. Highlight specific portions if relevant. • Include a list of questions below, and specify your needs. Examples: ( 1) general ["Please review project per HMP and MHCP guidelines."], or (2) specific [For each numbered comment, provide your specific question] • Include all comment letters, biological tech reports, graphic showing project footprint overlaid onto aerial photo, CEQA and NEPA documentation and any other reports, plans, or documents that are pertinent to this review. • Provide Michele Masterson with a copy of your signed routing sheet. ,....., """'· '-' """"" CITY OF CARLSBAD REVIEW AND COMMENT MEMO DATE: AUGUST 10, 2009 REVIEW NO: 3 TO: ~ Engineering, Development Services-Terie Rowley D Police Department -J. Sa sway FROM: i f8J. . Fe Department-James Weigand D Building Department -Will Foss D Recreation -Mark Steyaert D Public Works Department (streets)-Thomas Moore D Water/Sewer District ~ Landscape Plancheck Consultant -PELA D School District D North County Transit District -Planning Department D Sempra Energy -Land Management D Caltrans (Send anything adjacent to 1-5) D Parks/Trails-Liz Ketabian *ALWAYS SEND EXHIBITS PLANNING DEPARTMENT ··--·------------------------------, ;,.~. ~(JUEST FOR REVIEW AND COMMENT ON PROJECT NO(S): CT 06-27/CP 06-19/ ,., COP 06-32/HDP 06-10/HMP 07-02/GPA 06-09/ZC 06-08 PROJECT TITLE: Muroya Subdivision APPLICANT: __ _:C::..:.it:!.J.y-=o::..:...f-=C=a.:..:;rls=b=a=d _________________ _ PROPOSAL: 37 detached condo units. Please review and submit written comments and/or conditions to Michele Masterson in the Planning Department at 1635 Faraday Avenue, by 08/28/09. If you have "No Comments," please so state. Thank you COMMENTS: _____________________________________________ __ -PJOC.. /-1/fJ 111 o /{f/?I?.JJ1bJJttL GO}t')WleA~r...r ?-i-o9 PLANS ATTACHED Review & Comment 09/07 c 0 Memorandum TO: Jason Goff, Assistant Planner FROM: Clyde Wickham, Associate Engineer DATE: September 8, 2009 CT 06-27 I COP 06-32/ CP 06-19/GPA 06-09/HDP 06-10/LCPA 06-09/ZC 06-08 MUROYA RESIDENTIAL SUBDIVISION COMPLETENESS & ISSUES REVIEW Engineering Department staff has completed another review of the above-referenced project for application completeness. The application and plans submitted for this proposed project are from an Engineering perspective considered complete with issues to be resolved prior to support of the application(s). The following issues need to be resolved prior to resubmittal: 1. The remedial grading quantities shown on sheet 1 state 36,000 cy "remedial remove and recompact" with 36,000 cy export. Will there be a total of 38,570 cy exported? Will there be 36,00cy (structural/ clean fill) imported? Please review your estimated quantities and correct as necessary. I believe the proposed remedial grading is to remove 36,000 cy and export debris, and to import 36,000 cy of clean fill to recompact and stabilize. Adding these numbers to the remaining project quantities will resolve the conflict. 2. Show the house on the uphill and downhill pad of the Plantable (sideyard) Detail on sheet 2. Based upon the 5' sideyard setback shown on (2) details of the same sheet, the proposed retaining wall would be located 2' from the dwelling unit. The sideyard detail shows 3' positive drainage from buildings. The proposed retaining wall should also be shown on (2) Typical Surface Drainage, Building Setback Details to the right and below on the same sheet as well. 3. The request to reduce drainage distance between sideyards should be supported by your Geotechnical Consultant. Typically this request is backed up with Deepened footings, drainage system and possible curb to avoid saturation of building footings, retaining walls and fences between properties. The Geotechnical Report should support this request and should identify mitigation for the reduced positive drainage between buildings. An addendum will suffice to address these concerns and supply recommendations. 4. As we discussed, please submit 2 copies of the Geotechnical Investigation and Tentative map for 3rd party review. I will send out request for proposal as soon as I receive these copies. 5. The design speed for Street "A" is 25mph. Please correct the profile design on sheet 4. 6. Please submit support or easement information to allow the offsite connection to c Nightshade road. Also provide calculations to support the size and capacity of the facility downstream to accommodate this project. The Aviara Subdivision CT 90-15 has calculations and hydrology study that limits the capacity of downstream drainage facilities. Please address the ultimate upstream drainage in this system. 7. The Tentative Map Drainage Study discusses the detention basin(s) and standpipe overflow. Please clarify the capacity of the existing storm system you are using downstream. Will the increase (or decrease) have an impact on either downstream system? Please check more than just the immediate pipe. Follow the design a little further to be assured that capacity or watertight joints are necessary. The overflow design seems to flow to the headwall adjacent to Nightshade Drive, will there be capacity for both drainage basins (Carnation Project and Muroya property) at this location? How about downstream to Alga Road? Same question applies to the headwall at Caspian Lane to Alga Road. 8. Please show street lights (if existing) at Blackrail Road and Avena Ct. If you have any questions please contact let me at (760) 602-27 42 or email at Clyde.Wickham@carlsbadca.gov c Memorandum TO: Jason Goff, Assistant Planner FROM: Clyde Wickham, Associate Engineer DATE: July 17, 2007 PLANNING DEPT TRACKING DESK / REC'D: 0'"'0r@7 y I CT 06-27 I COP 06-32/ CP 06-19/GPA 06-09/HDP 06-10/LCPA 06-09/ZC 06-08 MUROYA RESIDENTIAL SUBDIVISION COMPLETENESS & ISSUES REVIEW Engineering Department staff has completed another review of the above-referenced project for application completeness. The application and plans submitted for this proposed project are from an Engineering perspective considered complete with issues to be resolved prior to support of the application(s). The following issues need to be resolved prior to resubmittal: 1. The drainage basin information (General Design Note 19, Sheet 1) should include City of Carlsbad Master Drainage Plan I Basin "C". 2. Please add remedial estimated grading quantities and limits of over excavation as identified in the geotechnical report dated 4/26/2006. 3. The Preliminary Geotechnical Report (dated 4/26/2006) identified several areas of Debris Fill, Undocumented Fill, Colluvium, and generally undesireable geologic conditions requiring remedial grading to support the proposed development. Please show the full extent of over cut, offsite slopes, keys or buttresses anticipated to provide a stable pad and building foundation. 4. Units 21, thru 29 and the Rec. Area should be consistent with City Standard GS-14 & GS-15. Provide slope setbacks, brow ditches and lot or boundary condition. Please review Units 35 thru 37 for the same issue. 5. The proposed Water Meter and Sewer Cleanout locations must be reconsidered. Please locate meters and cleanouts out of driveways and travel ways. The typical detail (P1 R, 3R, 4R) should be revised to correct the meter and sewer cleanout located within the proposed driveway. The notes: Typical Water Meter Locations . . . and Typical Sewer (meter?) Locations subject to change ... are not acceptable, please correct the mistake and remove the note. We understand change is a possibility, but the plan should be as close to an approved design. 6. Please show Right of Way for Typical Pedestrian Ramp Detail (sheet 2) 7. Please discuss parking detail with Planning Department. The 20' end space is permitted, provided there is drive in and out access. The proposed angled curb prohibits this maneuver. .. . .. 8. The parking on Drive "C" overhangs 5' sidewalk by 2.5 feet. Relocate sidewalk or parking or provide a wider sidewalk to accommodate both. The parallel parking on Drive "B" is also an issue per item 7 above. 9. The proposed street and access plan (private drive "B" and "C) is extremely congested and difficult to maneuver. The minimum street width Street "B" and "C" should be 34' within a 56' General Utility and access Easement, similar to Street "A". Our Hillside Ordinance allows for a 32' wide street, single loaded which would work fine as a compromise. 10. Please submit support or easement information to allow the offsite connection to Nightshade road. Also provide calculations to support the size and capacity of the facility downstream to accommodate this project. Submit copies of contact and negotiations with adjacent property owner to validate acquisition. 11. Please follow proposed drainage downstream to determine capacity or mitigation to accommodate the proposed project. Check-dams or downstream mitigation to address the additional runoff and velocity should be shown. Perhaps a basin (Structural BMP) and safe overflow structure could be provided on Lot 4. In reference, this is similar to DeJong Project CT 98-05 that your company designed and processed a few years ago with sensitive offsite drainage. 12. The Tentative Map Drainage Study section 1.3 discusses the detention basin and overflow. Please clarify the capacity of the existing storm System you are using downstream. Will the increase (or decrease) have an impact on either downstream system? Please check more than just the pipe connected to, follow the design a little further to be assured that capacity and watertight joints are necessary. The overflow design seems to flow to the Headwall, will there be capacity for both drainage basins at this location?. 13. Provide specific product or design specs for proposed water treatment unit(s). "Per Manufacturer" is insufficient to support the proposed system or BMP. 14. There are no street lights proposed along the project frontage (Black Rail Road), please take a look at this and revise if necessary. 15. Provide information to back up and explain why the power pole adjacent to Lot 2 and adjacent to Unit 37 needs to remain. We would hope this project would underground all power lines and poles along the complete project frontage. CARLSBAD FIRE DEPARTMENT Fire Protection Services PRELIMINARY REVIEW REPORT PROJECT NAME: Muroya Residential Subdivision Date: 6/12/07 Project number: CT 06-27 I CP 06-19 I CDP 06-32 Staff Planner: J. Goff Engineer: PLANN~NG DEPT TRACKING DESK/ REC'O: ok,le/o} Preliminary comments: (Note: This report identifies missing information that must be included with the official project submittal. It may also identify fire protection issues associated with the project.) Fire Department has reviewed this application and has the following comments or conditions to submit. 1. All dwelling units shall be provided with Automatic Fire Sprinklers. This item is a requirement because of the narrow street section (<36') and Fire Department vehicular access from the street places each proposed residence outside of our primary hose reach of 150 feet. This measurement is taken from the centerline of the street and as a man and hose would travel in a provided path of travel to the center of the furthest reaching wall of the dwelling. If you refer to the City Engineering Standard for Cul-de-sac streets you will find that cul-de-sac streets are to be 36 feet curb-to-curb with 24 DU's of less. This street is 34' curb-to-curb serving 34 units. If you were to use the livable streets concept plan you would find that 20 DU's are permitted on 36-foot streets and all dwelling units are sprinkled, with fire resistive construction on all DU's. 2. Pursuant to Section IV.F Fire Protection Program Policies and Requirements of the City of Carlsbad Landscape manual Item F.3-6, absolutely no combustible wood fencing shall be allowed within 100 feet of native undisturbed areas. 3. This shall also require that Lots 21 thru 27, 29 and 35 thru 37 be restricted as not to permit the construction or installation of combustible structures within 100 feet of undisturbed natural vegetation, examples of which would be pool houses, cabanas, gym sets and patio decks and covers/canopies. GR DATE: TO: FROM: c CITY OF CARLSBAD REVIEW AND COMMENT MEMO MAY, 25, 2007 REVISED PLANS ~ 2 ~ ~ D D D D ~ D D D D ~ ENGINEERING -DEVELOPMENT SERVICES, ATTN: TERIE ROWLEY POLICE DEPARTMENT-ATTN: J. SASWAY PLANN!NG DEPT FIRE DEPARTMENT-GREG RYAN TRACKING DESK BUILDING DEPARTMENT-MIKE PETERSON R&C•O: (1(4?/B()/p? RECREATION -MARK STEYAERT PUBLIC WORKS DEPARTMENT (STREETS)-THOMAS MOORE ___________ WATER/SEWER DISTRICT LANDSCAPE PLANCHECK CONSULTANT-PELA ___________ SCHOOL DISTRICT NORTH COUNTY TRANSIT DISTRICT-PLANNING DEPARTMENT SEMPRA ENERGY-LAND MANAGEMENT CAL TRANS (send anything adjacent to 1-5) PARKS/TRAILS-LIZ KETABIAN *ALWAYS SEND EXHIBITS PLANNING DEPARTMENT REQUEST FOR REVIEW AND COMMENT ON PROJECT NO(S): CT 06-27, CP 06-19, HOP 06-10. COP 06-32. HMP 07-02, GPA 06-09, ZC 06-08, LCPA 06-09 PROJECT TITLE: MUROYA SUBDIVISION APPLICANT: TAYLOR WOODROW HOMES INC PROPOSAL: RESIDENTIAL SUBDIVISION OF 2 RESIDENTIAL LOTS, 1 PRIVATE STREET/DRIVEWAY LOT AND 2 OS LOTS FOR THE CONSTRUCTION OF 37 DETACHED CONDOMINIUM UNITS ON 20.3 ACRES Please review and submit written comments and/or conditions to MICHELLE LENKOWSKI, Senior Office Specialist in the Planning Department at 1635 Faraday Avenue, by 06/13/2007. If you have "No Comments", please so state. If you have any questions, please contact JASON GOFF, at 602-4643. PLANS ATTACHED Review & Comment 01/07 CARLSBAD FIRE DEPARTMENT Fire Protection Services PRELIMINARY REVIEW REPORT PROJECT NAME: Muroya Residential Subdivision Date: 1102107 Project number: CT 06-27 I CP 06-19 I CDP 06-32 Staff Planner: J. Goff Engineer: Preliminary comments: (Note: This report identifies missing information that must be included with the official project submittal. It may also identify fire protection issues associated with the project.) Fire Department has reviewed this application and has the following comments or conditions to submit. 1. All dwelling units shall be provided with Automatic Fire Sprinklers. 2. All streets recorded as Fire Lanes, and subject to the restrictions and enforcements afforded to this designation. 3. On-street parking shall not be permitted on Pvt. Streets B and C as the street width is to narrow to accommodate any on-street parking. The bulb at the end of Pvt Street A shall also be designated as a No Parking zone. GR Gor::~~ / City of Carlsbad ·o~ • :m •caw .xg ·t• ''; .c=a ''' Date: December 21, 2006 To: From: Plan Review Recommendations Carlsbad Police Department's Crime Prevention Unit has provided the following optimal security recommendations. The purpose of this document is to safeguard property and public welfare by regulating and reviewing the design, construction, quality of materials, use and occupancy, location, and maintenance of all buildings and structures. The standards used in this document represent model international standards. Crime Prevention through Environmental Design The proper design and effective use of the built environment can lead to a reduction in the fear and incidence of crime and an improvement in the quality of life. The proper design influences this by positively affecting human behavior. The design includes the physical environment, the planned behavior of people, the productive use of space and an effective crime floss prevention program. Natural Surveillance 1. Place and design physical features to maximize visibility. This will include building orientation, windows, entrances, walkways, landscape trees and shrubs, fences and any other physical obstruction. 2. Design the placement of persons and or activities to maximize surveillance possibilities. 3. Design lighting that provides for appropriate nighttime illumination of walkways, entrances and driveways. Natural Access Control 1. Use sidewalks, pavement, lighting and landscaping to clearly guide guests to and from selected entrances. 2. Use real or symbolic barriers like fences or landscaping to prevent and or discourage access to or from dark and or unmonitored areas. Provisions for territorial reinforcement 1. Use pavement treatments, landscaping and fences to defme and outline ownership or property. • Homes Lighting 1. Keep in mind when creating a light plan: placement, intensity, reflection, balance, contrast, color and glare. Eyes see lighter colors better than dark. We loose 90% of the 2560 Orion Way • Carlsbad, CA 92010-7240 • (760) 931-2100 • FAX (760) 931-8473 <!) ., ' light we use if we place it around dark surfaces without anything to reflect the light. Unshielded lights cause a glare and reduce what they eye can see. 2. All types of exterior doors should be illuminated during the hours of darkness, with a minimum maintained one (1) foot-candle of light, measured within a five-foot radius on each side of the door at ground level. 3. Choose light fixtures with dawn to dusk sensors or timers. 4. Recessed areas of buildings or fences, which have a minimum depth of two feet, a minimum height of five feet, and do not exceed six (6) feet in width and are capable of human concealment, should be illuminated with a minimum maintained 0.25 foot- candles of light at ground level during the hours of darkness. This recommendation applies to defined recessed areas, which are within six feet of the edge of a designated walking surface with an unobstructed pathway to it, not hindered by walls or hedgerow landscaping a minimum of two (2) feet in height. 5. All exterior pedestrian walkways, interior common corridors, external community areas and open parking areas should be illuminated with a minimum maintained one (1) foot- candle of light on the walking or driving surface during the hours of darkness. 6. Accessible luminaries should have vandal resistant light fixtures and be not less than three feet in height from ground level when used to illuminate walkways and a minimum of eight feet in height from ground level when illuminating surfaces associated with vehicles. Light fixtures should be deemed accessible if mounted within fifteen feet vertically or six feet horizontally from any accessible surface or any adjoining roof, balcony, landing, stair tread, platform or similar structure. 7. Halide is a good light for use in large complexes. 8. The parking and drive surface lighting should have a rated average bulb life of not less than 10,000 hours. Landscaping 1. Plan a landscaping design that enhanced surveillance and security. 2. Tree canopies should be no lower than six (6) feet and should not allow access to roofs or balconies. 3. Let landscaping augment, not deter from lighting and addressing. 4. Plant only low profile shrubs and maintain below two (2) feet. 5. Use security plants where necessary to prevent entering and tampering. 6. Install walls and fences that are see through for surveillance. 7. Install lockable gates that allow surveillance 8. Keep entranceways clear of clutter Addressing 1. Locate numerals where they are clearly visible from the front street. 2. They should be a contrasting color to the background on which they are affixed. 3. Numerals shall be no less than four (4) inches in height and illuminated during the hours of darkness. 1. There should be positioned at each entrance of a multiple family dwelling complex with more than four buildings, an illuminated diagrammatic representation of the complex, which depicts the location of the viewer and the unit designations within the complex. It should be lighted during the hours of darkness. Entrances 1. Keep entranceways clear of clutter. Doors .· . ' . 1. Install wooden doors of solid core construction with a minimum thickness of one and three-fourths (1-3/4) inches. 2. Further, equip all doors with a single cylinder dead-bolt lock using a S-pin tumbler. Connect the dead bolt to the inner portion of the lock by connecting screws. Ensure the lock has a one-inch throw that can withstand a Cl,ltting tool attack. Choose a deadbolt that embeds at least three-fourths of an inch into the strike plate. Viewer 1. Arrange entrance doors so that the occupant has a view of the area immediately outside the door without opening the door. Except doors requiring a fire protection rating that prohibits them, such a view may be provided by a door viewer having a field of view of not less than 190 degrees. Mounting height should not exceed fifty-four (54) inches from the floor. Strike Plates 1. Reinforce all deadbolt strike plates. Choose Strike plates constructed of a minimum 16 U.S. gauge steel, bronze, or brass and secure it to the jamb by a minimum of two screws, which should penetrate at least two (2) inches into the solid backing beyond the surface to which the strike is attached. Keying 1. Upon occupancy by the owner, each single unit in a tract constructed under the same general plan, should have locks using combinations that are interchange free from locks used in all other separate dwellings. Window and sliding glass doors 1. All exterior sliding glass doors and windows should be equipped with locking devices which will keep the sliding panel of the door or window from being opened from the outside horizontally or vertically. Hinges 1. Equip hinges for out-swinging doors with non-removable hinge pins or a mechanical interlock to preclude removal of the door from the exterior by removing the hinge pins. • Recreation Areas and Club House Areas like passive plazas, tennis courts, and basketballs courts without good community surveillance become areas of negative behavior especially at night. 1. Place recreation areas inside the community allowing good lines of surveillance. Community policing and resident territoriality in these areas are key. Without these features they could become negative zones contributing to negative behavior. 2. Use sidewalks, pavement, lighting and landscaping to clearly guide guests to and from selected entrances. 3. Use real or symbolic barriers like fences or landscaping to prevent and or discourage access to or from dark and or unmonitored areas. · 4. All exterior pedestrian walkways, interior common corridors, and open parking lots should be illuminated with a minimum maintained one (1) foot-candle of light on the walking or driving surface during the hours of darkness. 5. Metal halide is a good commercial purpose light. . . . c 6. Overhead light poles should not be placed in an area planted with shade trees or other canopy producing species. Only basic ground cover, including but not limited to hedges and shrubs, should be used. 7. Accessible luminaries should have vandal resistant light fixtures and be not less than three feet in height from ground level when used to illuminate walkways and a minimum of eight feet in height from ground level when illuminating surfaces associated with vehicles. Light fixtures should be deemed accessible if mounted within fifteen feet vertically or six feet horizontally from any accessible surface or any adjoining roof, balc.ony, landing, stair tread platform or similar structure. 8. To provide greater visibility, demonstration of ownership (territorial reinforcement), an enhanced pedestrian environment, and a suitable buffer with the adjoining properties, the basic landscaping theme should consist of low ground cover with a maximum height of 2 feet and canopy trees with a minimum lower canopy of 6 feet. 9. Overhead light poles should not be placed in an area planted with shade trees or other canopy producing species. Only basic ground cover, including but not limited to hedges and shrubs, should be used. 10. Use security landscaping in areas to deter loitering or entrance where pedestrians are not wanted. Club Houses Lighting 1. Keep in mind when creating a light plan: placement, intensity, reflection, balance, contrast, color and glare. Eyes see lighter colors better than dark. We loose 90% of the light we use if we place it around dark surfaces without anything to reflect the light. Unshielded lights cause a glare and reduce what they eye can see. 2. All types of exterior doors should be illuminated during the hours of darkness, with a minimum maintained one (1) foot-candle of light, measured within a five-foot radius on each side of the door at ground level. 3. Choose light fixtures with dawn to dusk sensors or timers. 4. Recessed areas of buildings or fences, which have a minimum depth of two feet, a minimum height of five feet, and do not exceed six (6) feet in width and are capable of human concealment, should be illuminated with a minimum maintained 0.25 foot- candles of light at ground level during the hours of darkness. This recommendation applies to defined recessed areas, which are within six feet of the edge of a designated walking surface with an unobstructed pathway to it, not hindered by walls or hedgerow landscaping a minimum of two (2) feet in height. 5. All exterior pedestrian walkways, interior common corridors, external community areas and open parking areas should be illuminated with a minimum maintained one (1) foot- candle of light on the walking or driving surface during the hours of darkness. 6. Accessible luminaries should have vandal resistant light fixtures and be not less than three feet in height from ground level when used to illuminate walkways and a minimum of eight feet in height from ground level when illuminating surfaces associated with vehicles. Light fixtures should be deemed accessible if mounted within fifteen feet vertically or six feet horizontally from any accessible surface or any adjoining roof, balcony, landing, stair tread, platform or similar structure. 7. Halide is a good light for use in large complexes. 8. The parking and drive surface lighting should have a rated average bulb life of not less than 10,000 hours. Landscaping 1. To provide greater visibility, demonstration of ownership (territorial reinforcement), an enhanced pedestrian environment, and a suitable buffer with the adjoining properties, .. . . the basic landscaping theme should consist of low ground cover with a maximum height of 2 feet and canopy trees with a minimum lower canopy of 6 feet. 2. Overhead light poles should not be placed in an area planted with shade trees or other canopy producing species. Only basic ground cover, including but not limited to hedges and shrubs, should be used. 3. Use security landscaping in areas to deter loitering or entrance where pedestrians are not wanted. Addressing 1. Numerals should be located where they are clearly visible from the street on which they are addressed. They should be of a color contrasting to the background to which they are affixed. 2. Numerals should be no less than six inches in height, if located less than 100 feet from the centerline of the addressed street or 12 inches in height if placed further than 100 feet from the centerline of the addressed street. 3. The numerals should be illuminated during the hours of darkness. 4. The rear doors of all building should have address numbers not less than six inches in height and be of a color contrasting to the background to which they are affixed. Doors 1. The police department recommends that hollow steel doors be a minimum sixteen (16) U.S. gauge and have sufficient reinforcement to maintain the designed thickness of the door when any locking device is installed. 2. Only use glass doors with fully tempered glass or rated burglary resistant glazing. Protect all exterior doors with security hardware. 3. Equip all doors with a latch cover constructed of steel. Ensure the latch cover is a minimum of .125 inch thick. Attach the latch cover to the outside by welding or with non-removable bolts spaced apart on not more than ten-inch centers. 4. Construct the jamb of all aluminum frame-swinging doors to withstand 1600 pounds of pressure in both a vertical distance of three inches and horizontal distance of one inch each side of the strike, to prevent violation of the strike. 5. Equip rear doors used for shipping and receiving and employee entrances with a viewer. 6. A single or double door shall be equipped with a double cylinder deadbolt with a bolt projection exceeding one inch or a hook-shaped or expanding deadbolt that engages the strike sufficiently to prevent spreading. The dead bolt lock shall have a minimum of five- pin tumblers and a cylinder guard. Windows 1. Equip movable windows with security hardware and burglar resistant glazing. 2. Cover other vulnerable non-movable windows with burglar resistant glazing. Windows of commercial buildings are vulnerable to breakage during the hours of darkness when the business is non-operational especially windows within 40 inches of any door locking mechanism 3. Glaze should be constructed of either two part laminated glazing with a 0.60 inch inner layer or burglary resistant glazing Alarm Systems 1. When considering an alarm system, the police department recommends a "verified system" in an effort to eliminate false alarm activations and increase breach detection. A verified system is verified through audio or visual components. 2. If considering electronic assess as a security feature, consider managed electronic . { . . ~ ... I access. This information is a representation of information gathered on a national level. The purpose is to provide effective and consistent information. If you would like additional assistance concerning building security or employee security issues, please contact the Crime Prevention Unit at (760) 931-2105. By, Jodeene R. Sasway Crime Prevention Specialist Carlsbad Police Department (760) 931-2195 ·~ ~CARLSBAD ~i~~ ~d 1\h~\1\ LJ FILE Planning Division www.carlsbadca.gov November 16, 2011 Janet Stuckrath U.S. Fish and Wildlife Service 6010 Hidden Valley Road, Suite 101 Carlsbad, CA 92008 Libby Lucas California Department of Fish and Game 3883 Ruffin Road San Diego, CA 92123 SUBJECT: CT 06-27-MUROYA PROPERTY WITHIN ZONE 20 STANDARDS AREA Dear Ms. Stuckrath and Ms. Lucas: This letter is a request for concurrence that the Muroya project is consistent with the requirements and conservation standards of the City's Habitat Management Plan . (HMP). As detailed below, the project impacts will be mitigated in accordance with mitigation ratios contained in Table 11 of the HMP and all applicable HMP Adjacency Standards will be applied. The project site is located within the Local Facilities Management Zone 20 Standards Area and the Coastal Zone and is therefore subject to the zone-specific standards (beginning on page D-79 of the HMP) and the site-specific Coastal Zone conservation standards (beginning on D-114 of the HMP). Consistency with these standards is also described below. Mitigation Ratios for Habitat Impacts VEGETATION EXISTING IMPACTED MITIGATION MITIGATION REQUIREMENT COMMUNITY ACREAGE ACREAGE RATIO Southern Maritime 5.39 0.29 3:1 0.87 acres will be restored onsite Chaparral {5.3%) as Open Space (Lot 3&4) (Group B habitat) 5.1 acres (94.6%) will be preserved onsite as Open Space Southern Mixed 0.77 0.27 1:1 0.27 acres will be restored onsite Chaparral {6.5%) as Open Space (Lot 3&4) (Group D habitat) 0.50 acres (93.5%) will be preserved onsite as Open Space Agriculture 7.90 7.90 Mello II LCP In-lieu fee (Group F habitat) Ag. 10,000 per acre Mitigation Fee Disturbed Land 1.83 1.56 In-lieu fee In-lieu fee (Group F habitat) Totals 15.89 10.02 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 ® ' ... CT 06-27-MUROYA PROPERTY WITHIN ZONE 20 STANDARDS AREA November 16, 2011 Pa e 2 Adjacency Standards The project is located adjacent to and north of the future HMP Hardline Preserve. In order to minimize edge effects, the following adjacency standards have been incorporated into the project: 1. Fire Management: A Fire Protection Plan has been included as part of the project design and includes a 60-foot wide fire suppression zone between the proposed structures (Lots 21-27, 29 and 35-37) and the HMP Preserve boundary to the west. Fire Suppression Zones 2 and 3, which are closest to the HMP Preserve boundary, will be planted with a low water use, naturalizing plant species, known to have low fuel characteristics. As such, implementation of fire management requirements as proposed would be consistent with the HMP buffer requirements. 2. Erosion Control: Prior to construction of the proposed project, the project proponent shall develop an erosion control plan. The plan shall identify areas susceptible to erosion on the property and immediately adjacent to the existing HMP Preserve Area. All potentially sensitive slopes shall be stabilized and, if necessary, planted with native vegetation consistent with the plant community in the adjacent preserve area. The erosion control plan shall contain elements preventing runoff and the transport of fertilizers, pesticides, and similar materials into the existing HMP Preserve Area. 3. Landscaping Restrictions: The project shall prohibit the use of any non-native, invasive plant species in landscaping adjacent to the existing HMP Preserve or in any area where undesirable plant materials may have the opportunity to spread into the adjacent preserve area. The Final Landscape Plans prepared for the project shall include a list of HMP non-native invasive plant species that are to be avoided. Lastly, the project shall control landscape irrigation located adjacent to the existing HMP Preserve in order to prevent runoff from spreading into it. 4. Fencing, Signs, and Lighting: The proposed project has been designed to provide an Open Space Lot (Lot 3) between the proposed natural vegetated Open Space Lot (Lot 4) and residential Lots 21-27, 29 and 35- 37. A 6ft. tall tubular steel view fence is proposed along the rear property lines of Lots 21-27, 29 and 35- 37, which will further separate these two areas. Where Open Space Lot 3 and the Proposed HMP Preserve Area meet, a 4 to 5 ft. tall black vinyl coated chain link fence shall be constructed along the entire boundary. Sign age shall be installed on the fence to educate and inform the public about the goals of the HMP Preserve and to prohibit public access. Lighting in back yards adjacent to the existing HMP preserve area shall be of the minimum necessary for safety and security and shall be shielded and directed to shine downward and not into the HMP Preserve. Homeowner lighting restrictions shall be included in the project CC&R's. 5. Predator and Exotic Species Control: Project CC&R's shall educate homeowners regarding responsible pet ownership (e.g., keeping pets indoors, spaying/neutering pets, and not releasing pets into the wild). The proposed project has been designed to provide an Open Space Lot (Lot 3) between the proposed natural vegetated Open Space Lot (Lot 4) and residential Lots 21-27, 29 and 35-37. A 6 ft. tall tubular steel view fence is proposed along the rear property lines of Lots 21-27, 29 and 35-37, which will further separate these two areas. For exotic species control, the project shall not use any non-native, invasive plant species in landscaping adjacent to the existing HMP Preserve. The use of invasive exotic plant species as listed in the HMP shall be avoided. Additionally, in accordance with the HMP, the open space area shall be protected by a Conservation Easement and an endowment shall be established for long-term management, monitoring and reporting of the area in perpetuity. Title to the open space parcel shall be transferred to an appropriate land trust entity. CT 06-27-MUROYA PROPERTY WITHIN ZONE 20 STANDARDS AREA November 16, 2011 Pa e 3 Local Facilities Management Zone 20 Specific Standards The HMP conservation goals for Zone 20 require conservation of the majority of sensitive habitats in or contiguous with biological core and linkage areas, including no net loss of wetlands habitats, southern maritime chaparral, maritime succulent scrub, and coastal sage scrub within Core Area 6 and Linkage Area F. A habitat assessment of the project site was prepared by Dudek Engineering and Environmental in October and November of 2006 and later revised on November 2009. According to the report, the 20.27 acre site contains nine plant communities or land covers: Agricultural Lands (7.90 acres), Coastal Sage Scrub (2.03 acres), developed lands (1.11 acres), disturbed lands (1.83 acres), Native Grassland (0.19 acres), ornamental plantings (1.05 acres), Southern Maritime Chaparral (5.39 acres), Southern Mixed Chaparral (0.77 acres), and Waters of the U.S. (0.02 acres). No Narrow Endemic species, riparian habitats or wetlands are located within the property. There is 0.02 acres of waters of the U.S. however this is located within the upland plant community and does not contain any wetland or riparian habitat. The proposed project, which is directed by the HMP to cluster development on disturbed areas to the maximum extent feasible, will primarily impact agricultural and disturbed lands. The project is proposing grading and compacting of slopes within the project area that will impact a minor amount of Chaparral habitat. Impacts to 0.29 acres of Southern Maritime Chaparral and 0.77 acres of Southern Mixed Chaparral, will be mitigated by restoration of like habitat onsite. The subject site is identified as a Standards Area in the HMP and mitigation to a "no net loss" standard is required for impacts to sensitive habitats. Table 11 (Pg. D- 113) of the HMP identifies mitigation ratios for impacts to habitats identified as sensitive in the HMP. The HMP also allows impacts to agriculture and disturbed habitat areas to be mitigated through the payment of an in-lieu mitigation fee Coastal Zone Standards The HMP requires a 20-foot buffer for all other native habitats (i.e., coastal sage scrub) between preserved habitats and development. The HMP requires preservation of 67% the Coastal Sage Scrub (CSS) onsite, with a "no net loss" of CSS within the Coastal Zone. Project impacts to occupied CSS require a 2:1 mitigation ratio with a minimum 1:1 creation component that achieves the "no net loss" standard. As part of the project all CSS will be retained in an open space easement and will not be impacted. Based upon the analysis above, the City finds that the Muroya project is consistent with the HMP and hereby requests concurrence from the Wildlife Agencies. Supporting documentation for the above information is contained in the Mitigated Negative Declaration, publish date February 17, 2010, and the project specific "Biological Resources Technical Report and Impact Analysis" prepared by Dudek, dated February 2009, which were transmitted to the Wildlife Agencies on February 17, 2010. Please contact the project planner, Daniel Halverson at 760-602-4631, if you have any questions or require additional information. Sincerely, DON NEU, AICP Planning Director c: Chris DeCerbo, Principal Planner Michael Grim, Senior Planner Jack Henthorn & Associates P.O. Box 237 November 14, 2011 Dan Halverson Planning Department City of Carlsbad 1635 Faraday Avenue Carlsbad, California Carlsbad, California 92018-0237 (760} 438-4090 Fax (760} 438-0981 Subject: Grading Permit Items-MUROYA Dear Dan: RECEIVED NOV 1 4 2011 CITY OF CARLSBAD PLANNING DIVIS,ON Enclosed please find responses to each of the items noted in your e-mail of November 10, 1011. The final page in the package is a check list containing a summary of your comments along with status notes related to each item. As you will note, it appears that items 1, 3, 4, 7 and 8 can be determined to be complete in that they do not require further review by the City. The agricultural conversion (item 6) and HMP fees were paid this morning. You can check the computer to verify this. Finally, the Conceptual Upland Mitigation Plan (Item 5) has been revised to incorporate the comments from Environmental Management. A copy of detailed comments from Rosanne which provides detailed information on the location of each comment has been provided for ease of confirmation. Taylor Morrison is at a deadline point in their time line related to the property transaction where they must have the grading permit released so that the pre-con meeting can be established and a FIRM date set for the start of grading activities. Since it appears that the only item requiring confirmation on the part of the staff is item 5, it is requested that the review be expedited, so that planning can sign off on 1902 Wright Place, Ste 200, Carlsbad, CA 92t-08 the release of the grading permit. To this end, I am providing a separate copy of the updated Upland Mitigation Plan and associated e-mail directly to Mike Grim. Please contact me at your earliest convenience to discuss these items and confirm the release of the permit by planning. encl. cc: file DonNeu Mike Grim Document! -2- ' .. r SAN DIEGO NATURAL HISTORY MUSEUM BALBOA PARK-SAN DIEGO SOCIETY OF NATURAL HISTORY-ESTABLISHED 1874 9 November 2011 Ms. April Tomilla Taylor Morrison of CA, LLC 8105 Irvine Center, Suite 1450 Irvine, CA 92618 RE: Paleontological mitigation; Muroya Property Dear Ms. Tomilla: This letter is to confirm that the Department of Paleo Services at the San Diego Natural History Museum (SDNHM) has been retained by Taylor Morrison of CA, LLC to provide paleontological mitigation services during mass grading activities for the constructing of the Muroya Property project. The Museum is run and operated by the San Diego Society ofNatural History, which is a private non-profit scientific organization incorporated in 1874. Our proposed scope of work includes the following tasks: 1. attend any pre-construction meetings; 2. monitor the grading operations and inspect cuts for unearthed fossil remains; 3. salvage remains as they are uncovered; 4. document the stratigraphic and geologic context of salvaged fossil remains; 5. remove fossils from the project site; 6. clean, repair, and sort salvaged fossils for eventual donation to the SDNHM; 7. identify and catalog prepared fossil remains; 8. prepare a final report summarizing the results of the mitigation program. This report will include a discussion of methods employed, fossils recovered, geologic context of fossil remains, and significance of mitigation program. Please feel free to call me if you have any questions concerning our scope of work. Sincerely, ~.u- Melissa Soetaert Office/Curatorial Manager Department of Paleo Services Post Office Box 121390 *San Diego, California 92112-1390 *Telephone 619-232-3821 *FAX 619-255-0187 * www.sdnhm.org r • r SAN DIEGO NATURAL HISTORY MUSEUM BALBOA PARK-SAN DIEGO SOCIETY OF NATURAL HISTORY-ESTABLISHED 1874 9 November 2011 Ms. April Tomilla Taylor Morrison ofCA, LLC 8105 Irvine Center, Suite 1450 Irvine, CA 92618 RE: Paleontological mitigation; Muroya Property Dear Ms. Tomilla: The following paleontological monitors may participate in the construction monitoring of excavation operations at the above mentioned project site: Ms. Shayne Boney Mr. Gino Calvano Mr. Richard A. Cerutti Mr. John L. Pfanner Mr. Christopher S. Plouffe Mr. Bradford 0. Riney Mr. Patrick J. Sena Mr. Donald R. Swanson Mr. Todd Wirths The Principal Investigators are Dr. Thomas A. Demere and Sarah A. Siren. If you have any additional questions, please feel free to contact me at ( 619) 255-0309 or msoetaert@sdnhm.org. Sincerely, ti.JJ- Melissa Soetaert Office/Curatorial Manager Department of Paleo Services Post Office Box 121390 *San Diego, California 92112-1390 *Telephone 619-255-0309 *FAX 619-255-0187 * www.sdnhm.org DUDEK November 4, 2011 April Tornillo, P.E. Land Project Manager Taylor Morrison of CA, LLC 8105 Irvine Center Drive, Suite 1450 Irvine, CA 92618 5332-03 Subject: Avoidance of Breeding Bird Impacts for the Muroya Project, Carlsbad, California Dear Ms. Tornillo: Dudek has prepared a number of biological resource documents and conducted a number of focused surveys for the Muroya Project, located in the City of Carlsbad (City), California. The mitigation and avoidance requirements are outlined in the Biological Resources Technical Report (BTR), dated February 2010 and also summarized in the Mitigated Negative Declaration prepared by the City. The federally listed threatened coastal California gnatcatcher (Polioptila californica) was detected onsite. Two pairs were observed: one in the central part of the site and one in the southern portion. Both pairs are anticipated to be preserved onsite and no impact to coastal sage scrub, their preferred habitat, is proposed. However there are very small impacts to southern maritime chaparral and southern mixed chaparral, habitat that can be used by California gnatcatcher or other sensitive bird species. To avoid indirect impacts to the species, mitigation measures are proposed that would prohibit clearing, grubbing, grading or other construction activities in the coastal sage scrub from February 15 to August 30, which is the breeding season of the California gnatcatcher. In addition, during the breeding season, no construction activities will occur within any portion of the site where they would result in noise levels exceeding 60 dB( A) hourly average at the edge of the coastal sage scrub habitat if nesting birds are present. In order to implement the avoidance and protection of the California gnatcatcher within the preserve area onsite, if clearing, grubbing, grading or other construction activities are anticipated to occur during the breeding season (February 15 through August 30), within the potentially suitable habitat of the species, a focused survey will be conducted immediately prior to the clearing activities. The survey will be conducted in accordance with the currently accepted U.S. WWW.DUDEK.COM . . Ms. April Tornillo Subject: Avoidance of Breeding Bird Impacts for the Muroya Project, Carlsbad, California Fish and Wildlife Service protocol. The survey includes conducting three survey visits approximately one week apart within the suitable habitat. If the California gnatcatcher or other sensitive bird species are determined to be nesting within the area proposed to be impacted, the clearing or other construction activity will be postponed until after the breeding season or until the birds are determined to be finished with their nesting activity. In addition to construction resulting in direct impacts to California gnatcatcher and other sensitive birds, construction activity, including grading has the potential to indirectly impact nesting birds that are protected under the Migratory Bird Treaty Act. Construction noise should be avoided during the breeding season by avoiding grading during that time. However, this restriction can be waived by the City of Carlsbad with concurrence from the Wildlife Agencies upon completion of a nesting bird survey. The sur-Yey will be conducted immediately prior to any grading activity during the breeding season and will include surveying within 500 feet of the limits of grading. If nests are present within 500 feet of the proposed grading, no grading or removal of habitat may take place until the nesting season is over or until the project biologist confirms that the nesting birds have completed breeding. A buffer will be established around any nests observed in coordination with the project biologist. The buffer will ensure that no noise levels will exceed 60 dB(A) hourly average at the edge of the habitat. Please feel free to contact me at 760.479.4239 with questions or if you require additional information. Sincerely, ~~ Senior Project Manager/Senior Biologist cc: Jack Henthorn, Jack Henthorn Associates DUDEK 2 25332-03 November 4, 2011 _4(~~ CITY OF VcARLSBAD Planning Division August 24, 2011 Jack Henthorn c/o Jack Henthorn & Associates P.O. Box 237 Carlsbad, CA 92018 www.carlsbadca.gov SUBJECT: NOTICE OF RESTRICTION and NOTICE CONCERNING AIRCRAFT -CT 06-27/CP 06- 19/CDP 06-32/HDP 06-10/HMPP 07-02-MUROYA SUBDIVISION Dear Applicant: Please find the enclosed Notice of Restriction and Notice Concerning Aircraft that needs to be signed, notarized, and returned for recordation. This is to fulfill a condition of approval of the CT 06-27 /CP 06- 19/CDP 06-32/HDP 06-10/HMPP 07-02-MUROYA SUBDIVISION. Please ensure the following items are addressed prior to returning the Notice of Restriction: ../ Correct Notary Acknowledgement Required (Effective January 1. 2008, all Certificates of Acknowledgement used by a California notary on a document that will be recorded in the State of California must NOT HAVE "PERSONALLY KNOWN TO ME" in the acknowledgement. (Assembly Bill 886, Chapter 399)) ../ Document must be properly notarized . ../ Name on signature page and name on Notarial Acknowledgement must match . ../ Property owner's signatures/initials must be the same as on Notary Acknowledgement . ../ Notary seal cannot be blurry/too light (County will not record the document if any portion of the Notary Seal is blurry or too light) ../ Include property owner's name in the designated space above the owner's signature . ../ Please pay particular attention to the signature requirements at the bottom of the signature page. It is our goal to assist you in getting the Notice of Restriction recorded as expeditiously as possible. If you have any questions or need additional assistance, please contact Michele Masterson, Senior Management Analyst at (760) 602-4615 or via email at michele.masterson@carlsbadca.gov. DAN HALVERSON Assistant Planner c: April Tornillo, Taylor Morrison of CA, LLC, 15 Cushing, Irvine, CA 92618 CED Senior Management Analyst File Copy ~~·-------------------------------------------------------------··:-1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 ~· 4~ CITY OF VcARLSBAD Planning Division July 14, 2011 Toni Ross California Coastal Commission 7575 Metropolitan Dr, Suite 103 San Diego CA 92108 RE: MUROYA LCPA (CITY OF CARLSBAD LCP AMENDMENT NO. 1-lOA) Toni, www.carlsbadca.gov The City Planning Department has been made aware of your Geo Technical issues regarding soil conditions and the debris/undocumented fill remediation. The following information is provided to demonstrate that the project design complies with all regulations, including the Coastal Commission endorsed HMP. • The HMP states {Page D-119): "Assessor's Parcel No. 215-040-03 (Muroya) -Cluster development on disturbed areas to the maximum extent feasible. Maximum 10% impact on CSS and SMC for access purposes." This lot is a "Standards Area" and this is what the Coastal Commission agreed to when approving our HMP. The City-approved project design clusters the development on disturbed areas to the maximum extent feasible and in fact, abandons disturbed areas that are located internal to the proposed open space preserve lot in favor of creating a more viable environmental condition for the future. Pursuant to the HMP, the development envelop on this site is defined as the disturbed areas of the site. Development is to be clustered specifically in these areas. The subject slope area is within the disturbed area of the site. As such, there are no requirements to locate development away from the top of the slope beyond those imposed by the Carlsbad Hillside Development Ordinance. There is no defined bluff edge on this site and the design meets the setback requirements for slope edge conditions. As a result of the project design, significant amounts of otherwise developable, disturbed areas are being re-vegetated and incorporated into the open space preserve lot. Since access is an integral part of the clustering of development within the disturbed area, the HMP provides for a maximum of 10 percent impact on SMC to accommodate access. The language does not state that there is a requirement for a road to be located in the area of impact, but simply indicates that such impact is permitted for access purposes. In this instance, the placement of the road in its most efficient location within the disturbed area results in an impact of 5 percent to SMC. The location of the 1.5 safety factor limit is immaterial. The necessity of the grading as an integral part of the clustered design is documented both in the soils report and the supplemental letter of June 22, 2011. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 MUROYA LCPA (CITY OF CARLSBAD LCP AMENDMENT NO. 1-10A) July 13, 2011 Pa e 2 It is my understanding that the developer, in response to your request, is providing a copy of the requested plotting for the purpose of demonstrating that that location of the 1.5 safety factor line has been established. However, as previously noted, the location of this point should have no bearing on the site plan since all proposed development (grading) has been approved pursuant to the HMP language. DON NEU, AICP City Planner c: Sherilyn Sarb, California Coastal Commission Lesley Ewing, California Coastal Commission Jack Henthorn, PO Box 237, Carlsbad CA 92008 Don Neu, City Planner Chris DeCerbo, Principal Planner Dan Halverson, Assistant Planner .4f~A_ C I T Y 0 F VcARLSBAD Planning Division www.carlsbadca.gov February 8, 2011 Ms. Deborah Lee California Coastal Commission San Diego Regional Office 7575 Metropolitan Drive San Diego, California 92108 SUBJECT: MUROYA LCPA (CITY OF CARLSBAD LCP AMENDMENT NO.l-10 A (MUROYA)) Dear Deborah, I have been approached by the applicant and property owner of the Muroya property regarding their need to move forward with the pending LCPA to meet certain contractual obligations relating to the property. It is my understanding that the Commission granted a time extension for the processing of the pending LCPA due to Commission staff work load related to pending City of Carlsbad items, including code revisions and the Habitat Management Plan. Since we are involved in on-going issue resolution discussions related to the pending City items, it is requested that you expedite the Muroya application. Thank you for your cooperation. Please feel free to contact me at 760-602-4601 should you wish to discuss this request. Sincerely yours, QLnu DON NEU, AICP Planning Director c: Jack Henthorn, JHA Chris DeCerbo, Principal Planner Dan Halverson, Assistant Planner Kevin Pointer, Associate Planner 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 ® 4~~ CITY OF ~~CARLSBAD Planning Division www.carlsbadca.gov September 22, 2010 Deborah Lee San Diego Coast District California Coastal Commission 7575 Metropolitan Drive, Suite 103 San Diego, CA 92108 RE: CITY OF CARLSBAD LCP AMENDMENT #1-10 Dear Ms. Lee, This transmittal is in response to your September 9, 2010 letter regarding the incomplete/unfiled status of the city's first Local Coastal Program (LCP) Amendment application of the 2010 calendar year (LCP Amendment #1-10). Included with this transmittal is the information necessary for the executive director of the California Coastal Commission to deem the city's application submitted. The attached information consists of two attachments that provide the information you requested related to each of the following components of the City of Carlsbad's LCP Amendment (#1-10): 1. Muroya Subdivision-LCP Amendment 1-10 A 2. Village Area Title Amendment-LCP Amendment 1-10 B As detailed in my August 2, 2010 letter, the City is requesting that this component of the City's LCP Amendment be considered and processed as de minimis. If you have any additional questions, please do not hesitate to contact the individual planners assigned to each of the aforementioned projects using the respective email/phone numbers contained herein. Sincerely, ~~~£ KEVIN POINTER Associate Planner c: Gary Barberio, Community and Economic Development Director David de Cordova, Principal Planner Corey Funk, Associate Planner Daniel Halverson, Assistant Planner Jennifer Jesser, Senior Planner Don Neu, Planning Director 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 ® t • " ~ ~CARLSBAD Planning Division www.carlsbadca.gov September 22, 201 0 Deborah N. Lee California Coastal Commission San Diego Area 7575 Metropolitan Drive, Suite 103 San Diego, CA 92108-4421 SUBJECT: RESPONSE TO CALIFORNIA COASTAL COMMISSION LETTER DATED SEPTEMBER 9, 2010 -RE: CITY OF CARLSBAD LCP AMENDMENT #1-lOA (Muroya Subdivision)-CITY REFERENCE LCPA 06-06 Dear Ms. Lee, This letter is in response to your September 9, 2010 letter, whereby you requested several additional items to assist in completing your review of LCP Amendment # 1-1 OA (Muroya Subdivision). We have compiled each of the items that you have requested and enclosed them as part of this letter. Below is a breakdown of each item raised in your letter and a brief explanation of how we have addressed your concern, or instead, where in the application submittal you can find the information necessary to address your concern. Item No. 1: You have requested a copy of the habitat assessment that was prepared for the site, including a topographic/slope analysis, a color vegetation map, and any gnatcatcher surveys that were prepared. For your records, please find enclosed a copy of the biological study (Biological Resources Technical Report and Impact Analysis for the Muroya Property, prepared by Dudek in November, 2009) that was prepared for the project and used in our environmental analysis. The Gnatcatcher survey is provided within this report (Appendices D) and is referenced within the staff reports (Exhibit "G" of the Application for Local Coastal Program Amendment sent with the initial application) and within all environmental review documents (Exhibits "C 1, C2, and G"). The report also includes several vegetation maps (Page 11, 27, and 35). Also for your reference is a full size set of the "Hillside Development Permit Constraints Map" which also includes a "Cut/Fill" exhibit, a "Bio/Slope" analysis, a "Dual Criteria Impact" analysis, a "40% Slope Overlay with Geology" exhibit, and a "40% Slope Overlay with Biology" exhibit. Item No. 2: You have requested a copy of the HMP permit that was processed with the other permits for this project. For your records, please find enclosed a copy of the Planning Commission Staff report and the signed HMP resolution (Resolution No. 6690). These items may also be found in the initial submittal package in Exhibit "G." 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 ® CITY OF CARLSBAD LCP AMENDMENT #1-lOA (Muroya Subdivision-LCPA 06-06) September 22, 20 I 0 Page 2 Item No. 3: You have requested an address for the speaker (Vince Lombardi) that was present at the City Council meeting on June 22, 2010. Mr. Vincent Lombardi resides at 1377 Nightshade Dr, Carlsbad, CA 92011. I hope this helps in expediting the processing of our LCP A application. If you have any additional questions, or would like to discuss these matters further, please do not hesitate to contact me via email at Daniel.Halverson@carlsbadca.gov, or by telephone at (760) 602-4631. Sincerely, 1 / fl eLk~ I • DAN HALVERSON Assistant Planner DH: C: Jack Henthorn & Associates, P.O. Box 237, Carlsbad, CA 92018 Toni Ross, California Coastal Commission, San Diego Area Don Neu, Planning Director Chris DeCerbo, Principal Planner Kevin Pointer, Associate Planner STATE OF CALIFORNIA-THE NATURAL RESOURCES AGENCY ARNOLD SCHWARZENEGGER, Governor CALI FORNIA COASTAL COMMISSION DIEGO AREA METROPOLITAN DRIVE, SUITE 103 SAN DIEGO, CA 92108-4421 CITY OF CARLSBAD (619) 767-2370 Kevin Pointer Associate Planner City of Carlsbad Planning Division 1635 Faraday Avenue Carlsbad, CA 92008 Community & Economic Development Department September 9, 2010 Re: City of Carlsbad LCP Amendment #i -10 A (Muroya Subdivison) and B (Village Area Title Amendment) Dear Mr. Pointer, In response to your cover letter, dated August 2, 2010, this letter addresses the status of the City of Carlsbad's first amendment submittal for this calendar year. This amendment package was received here on August 2nd as well; and, as noted above, it includes two separate and unrelated items. The package includes changes to both the land use plan designations and companion rezoning for the Muroya property and further updating of the Village Area Master Plan and Design Manual, as well as it zoning ordinance, to primarily reflect the expiration of the redevelopment area designation from the planning area. Therefore, as a whole, the amendment package will amend both the City's certified LCP land use plan(s) and implementation plan. Section 13553 of the California Code.ofRegulations states "[a]n amendment to a certified LCP or LRDP together with all necessary attachments and exhibits shall be deemed "submitted" after having been received and found by the executive director of the Commission to be in proper order and legally adequate to comply with Public Resources Code Section 3 051 O(b ). Said review shall be completed within a reasonable time, but unless there are unusual circumstances, no later than ten ( 1 0) working days after the date it is received in the Commission offices during normal working hours[ ... ]". Due to existing LCP workload, staffing constraints and imposed statewide furloughs, we have had to take additional time to review this submittal. Although both amendment requests were quite thorough and well-organized, as of the date ofthis letter, the amendment package is not complete or deemed filed. The entire submittal will not be deemed complete until all the outstanding items for each component has been received. The following paragraphs will describe the outstanding items for each component. For the Muroya Subdivision amendment, City reference LCPA 06-06, this submittal was very complete, with the exception of certain exhibits and background information identified below, and very well-organized. While a cursory review of the submittal indicates that the recent history of the site was a palm tree nursery, the information also Q indicates the site is included as a "Standards Area" in the City's adopted Habitat Management Plan (HMP) which has been incorporated into the LCP. Given that an important part of our review will be to evaluate and establish the appropriate • Kevin Pointer City of Carlsbad LCP Amendment #1-10 AlB September 9, 2010 Page 2 development envelope for the property, as well as consider future development in the context of the HMP implementation efforts, we will need to have the habitat assessm~ d) and topographic/slope analyses prepared for the site, including color vegetation maps and {ff!-r-s-_ ~natcatcher surveys. Hopefully, these documents are part ofthe City's d--------environmental review materials and/or discretionary review file for the companion ~ subdivision and are readily available. In addition, please forward a copy of the project's HMP Permit (HMPP 07-02). While the actual discretionary reviews (i.e. Hillside Development Permit and Coastal Development Permit) for the subdivision will be or likely have been processed by the City and are not directly before the Coastal Commission, the City's staff reports for those actions may inform and provide important background material for our review of the proposed LCP amendment. Therefore, if those reviews have been finalized, please provide a copy of those staff reports or provide a status report on those actions. Lastly, for a minor administrative record component, can you please provide an address for the ~ one speaker (Mr. Vince Lombardi) at the City Council hearing? Unlike the Planning ~~.._, ----rc....,-o--mm--=-~Is:-:"src;;_ minutes, there was no address provided for City Council participants. Relative to the proposed amendment for the Village Area, City reference LCP A 1 0-01 , the submittal again was quite thorough. For it, we only need a copy ofthe adopted City Council minutes and confirmation that there were no other written comments received throughout the local hearings to complete the submittal. Once we receive all of the identified items and review your responses, we will be able to proceed with our more detailed review. As always, ifthere are any other supplemental materials that the City has on record for either item that you or other City staff believes would be helpful, please provide them as well. Given that we continue to work under staffing constraints and the re-imposed furloughs, we certainly appreciate your assistance and patience. I have copied this letter to your colleagues and we thank you in advance for your attention to providing the above information. Please call Toni Ross of our staff or me if you have any questions or need to discuss the above mentioned items. cc: Toni Ross Sherilyn Sarb Don Neu Dan Halverson \.> Corey Funk s· rely, "~/. \../~ ~ .;[ r !"; r1 // j v {,(/(;\' ·,_, 1 .. ,;/{-·< ---. Deborah N. Lee - District Manager (G:\San Diego\Toni:Carlsbad LCPA 1.10 A (Muroya Subdivision) and B (Village Area Title) non filing ltr.doc) (~CITY OF ~·"·~ CARLSBAD Planning Division www.carlsbadca.gov August 2, 2010 Deborah Lee San Diego Coast District California Coastal Commission 7575 Metropolitan Drive, Suite 103 San Diego, CA 92108-4402 SUBMITTAL: CARLSBAD LOCAL COASTAL PROGRAM AMENDMENT (LCPA): 1-10 Please find enclosed the first City of Carlsbad LCPA package for the 2010 calendar year. The LCPA batch involves the projects as shown below. PROJECT NAME 'LCPAFILE# 'STAFF PLANNER PHONE CONTACT Muroya Subdivision LCPA 06-06 Dan Halverson 760-602-4631 Village Area Title Amendment LCPA 10-01 Corey Funk 460-602-4645 Please process this application as the first of three Local Coastal Program Amendments for the City of Carlsbad for the 2010 calendar year. Additionally, The City of Carlsbad is requesting that the following amendment: Village Area Title Amendment (GPA 10-01/LCPA 10-01/ZCA 10-02), be reviewed and determined to be de minimis by the executive director of the California Coastal Commission. Carlsbad staff considers the Village Area Title Amendment submittal to be consistent with the criteria for de minimis review required by Section 30514 of the Coastal Act, as outlined below: • The executive director of the Coastal Commission determined the previous Village Master Plan and Design Manual/Redevelopment Plan amendment (LCPA #03-09) was de minimis. On November 5, 2009 the commission concurred with the executive director's determination (staff report Th27b}, which made numerous minor changes to Carlsbad's Village Master Plan and Design Manual and Zoning Ordinance related to the expiration of the Village Redevelopment Plan. • The proposed LCPA 10-01 Village Area Title Amendment is a follow-up to the above project and consists of minor amendments to correct terminology related to the Village area and to remove the term "redevelopment" from references to the Village area. No changes to policies or standards are proposed. • The proposed amendment will not change the land use or the allowable use for any property. • The proposed amendment will have no impact on coastal resources and is consistent with Chapter 3 of the Coastal Act. . " • Notice to the public was provided consistent with Section 30514( d) of the Coastal Act ~ • No public comments were received regarding LCPA 10-01. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 ® Carlsbad Local Coastal Program Amendment 1-10 August 2, 2010 Page2 If you have any questions, or require additional information, please feel free to contact me at (760) 602-4620, or the project planners at the numbers listed above. Thank you for your consideration. Sincerely, v-P~ KEVIN POINTER Associate Planner enc c: Gary Barberio, Community and Economic Development Director David de Cordova, Principal Planner Dan Halverson, Assistant Planner Corey Funk, Associate Planner Jennifer Jesser, Senior Planner Don Neu, Planning Director _, SAN DIEGO CO~TY REGIONAL AIRPORT AUTHORITY P.O. BOX 82776. SAN DIEGO, CA 92138-2776 619.400.2400 'w''w''w'.SAN.ORG May 19,2010 Mr. Dan Halverson City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 0 CITY OF CARLSBAD MAY 2 4 ZOlO Community & Economic Development Department Re: Airport Land Use Commission Consistency Determination-6697 Black Rail Road, City of Carlsbad; General Plan Amendment and Zone Reclassification to construct 3 7 single-family residential units; APN 215-040-03; McClellan-Palomar Airport -Airport Land Use Compatibility Plan-PAL-10-002; Resolution No. 2010-0029 ALUC Dear Mr. Halverson: This letter is to notify the City of Carlsbad ("City") of the May 6, 2010, consistency determination that was made by the San Diego County Regional Airport Authority ("Authority" or "SDCRAA"), acting in its capacity as the San Diego County Airport Land Use Commission ("ALUC"), for the referenced project. The ALUC has determined that the proposed project is conditionally consistent with the McClellan-Palomar Airport-Airport Land Use Compatibility Plan ("ALUCP"). A copy of Resolution 2010-0029 ALUC, approved by the ALUC on May 6, 2010, and memorializing the consistency determination, is enclosed for your information. The ALUC's determination that the 6697 Black Rail Road project is conditionally consistent with the McClellan-Palomar ALUCP was made consistent with the ALUC Policies and the State Aeronautics Act provisions (Cal. Pub. Util. Code §21670-21679.5), and was based on numerous facts and findings, including those summarized below: 1) The proposed project involves a general plan amendment and zone reclassification to construct 37 detached, single-family residential units with one existing, detached single- family residence to remain. 2) The proposed project is located outside the 60 dB CNEL noise contour. The ALUCP identifies residential uses located outside the 60 dB CNEL noise contour as compatible with airport uses. 3) The proposed project is in compliance with the ALUCP airspace protection surfaces because it does not exceed an airspace threshold which would require an obstruction evaluation from the FAA. SAN DIEGO INTERNATIONAL AIRPORT '· Mr. Halverson Page2 0 0 4) The proposed project is located within Safety Zone 6 of the ALUCP. The ALUCP identifies residential uses located within Safety Zone 6 as compatible with airport uses. 5) The proposed is located within the overflight notification area. The ALUCP requires that an overflight notification for new residential land uses be recorded with the County Recorder. Therefore, as a condition of project approval, an overflight notification must be recorded with the County Recorder for the new residences proposed by the project. 6) Therefore, if the proposed project contains the above-required conditions, the proposed project would be consistent with the McClellan-Palomar Airport ALUCP. 7) This Board action is not a "project" as defined by the California Environmental Quality Act (CEQA) Pub. Res. Code Section 21065; and is not a "development" as defined by the California Coastal Act Pub. Res. Code Section 30106. Please contact Ms. Sandi Sawa at (619) 400-2464 if you have any questions regarding the issues addressed in this letter. Thella F. Bowens President/CEO TFB/SS Enclosures: Resolution 2010-0029 ALUC cc: Amy Gonzalez, SDCRAA-General Counsel Terry Barrie, Caltrans-Division of Aeronautics •. RESOLUTION NO. 2010-0029 ALUC A RESOLUTION OF THE BOARD OF THE SAN DIEGO COUNTY REGIONAL AIRPORT AUTHORITY MAKING A DETERMINATION THAT THE PROPOSED PROJECT: GENERAL PLAN AMENDMENT AND ZONE RECLASSIFICATION TO CONSTRUCT 37 SINGLE-FAMILY RESIDENTIAL UNITS AT 6697 BLACK RAIL ROAD, CITY OF CARLSBAD, IS CONDITIONALLY CONSISTENT WITH THE MCCLELLAN-PALOMAR AIRPORT - AIRPORT LAND USE COMPATIBILITY PLAN. WHEREAS, the Board of the San Diego County Regional Airport Authority, acting in its capacity as the Airport Land Use Commission (ALUC) for San Diego County, was requested by the City of Carlsbad to determine the consistency of a proposed development project: General Plan Amendment and Zone Reclassification to Construct 37 Single-Family Residential Units at 6697 Black Rail Road, City of Carlsbad, which is located within the Airport Influence Area (AlA) for the McClellan-Palomar Airport -Airport Land Use Compatibility Plan (ALUCP), adopted in March 2010; and WHEREAS, the plans submitted to the ALUC for the proposed project indicate that it would involve a general plan amendment and zone reclassification to construct 37 detached, single-family residential units with one existing, detached single-family residence to remain; and WHEREAS, the proposed project would be located outside the 60 decibel (dB) Community Noise Equivalent Level (CNEL) noise contour, and the ALUCP identifies residential uses located outside the 60 dB CNEL noise contour as compatible with airport uses; and WHEREAS, the proposed project is in compliance with the ALUCP airspace protection surfaces because it does not exceed an airspace threshold which would require an obstruction evaluation from the Federal Aviation Administration (FAA); and WHEREAS, the proposed project is located within Safety Zone 6 of the ALUCP, and the ALUCP identifies residential uses located within Safety Zone 6 as compatible with airport uses; and WHEREAS, the proposed project is located within the overflight notification area, and the ALUCP requires that an overflight notification for new residential land uses be recorded with the County Recorder; and . . c Resolution No. 2010-0029ALUC Page2 of3 WHEREAS, the Board has considered the information provided by staff, including information in the staff report and other relevant material regarding the project; and WHEREAS, the Board has provided an opportunity for the City of Carlsbad and interested members of the public to present information regarding this matter. NOW, THEREFORE, BE IT RESOLVED that the Board, acting as the ALUC for San Diego County, pursuant to Section 21670.3 of the Public Utilities Code, determines that the proposed project: General Plan Amendment and Zone Reclassification to Construct 37 Single-Family Residential Units at 6697 Black Rail Road, City of Carlsbad, is conditionally consistent with the McClellan- Palomar ALUCP, which was adopted in March 2010, based upon the following facts and findings: (1) The proposed project involves a general plan amendment and zone reclassification to construct 37 detached, single-family residential units with one existing, detached single-family residence to remain. {2) The proposed project is located outside the 60 dB CNEL noise contour. The ALUCP identifies residential uses located outside the 60 dB CNEL noise contour as compatible with airport uses. {3) The proposed project is in compliance with the ALUCP airspace protection surfaces because it does not exceed an airspace threshold which would require an obstruction evaluation from the FAA. {4) The proposed project is located within Safety Zone 6 of the ALUCP. The ALUCP identifies residential uses located within Safety Zone 6 as compatible with airport uses. (5) The proposed project is located within the overflight notification area. The ALUCP requires that an overflight notification for new residential land uses be recorded with the County Recorder. Therefore, as a condition of project approval, an overflight notification must be recorded with the County Recorder for the new residences proposed by the project. (6) Therefore, if the proposed project contains the above-required conditions, the proposed project would be consistent with the McClellan-Palomar Airport ALUCP. Resolution No. 2010-0029ALUC Page3 of3 BE IT FUTHER RESOLVED that this Board action is not a "project" as defined by the California Environmental Quality Act (CEQA), Pub. Res. Code Section 21065, and is not a "development• as defined by the California Coastal Act, Pub. Res. Code Section 30106. PASSED, ADOPTED AND APPROVED by the Board of the San Diego County Regional Airport Authority at a regular meeting this 6th day of May, 2010, by the following vote: AYES: Board Members: NOES: Board Members: ABSENT: Board Members: APPROVED AS TO FORM: BRETON K. LOBNER GENERAL COUNSEL Boland, Cox, Desmond, Finnila, Panknin, Smisek None Gleason, Young ATIEST: USSELL DIREC I CORPORATE SERVICES/ AUTHORITY CLERK SAN DIEGO COQTY REGIONAL AIRPORT AUTHORITY P.O. BOX 82776. SAN DIEGO. CA 92138-2776 619.400.2400 W'W'W'.SAN.ORG April 21, 2010 Mr. Dan Halverson City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 Re: Airport Land Use Commission Determination 0 CITY OF CARLSBAD APR 2 2 2010 Community & Economic Development Department General Plan Amendment and Zone Reclassification to construct 37 single-family residential units at 6697 Black Rail Road, City of Carlsbad; APN 215-040-03 · Dear Mr. Halverson: As the Airport Land Use Commission (ALUC) for San Diego County, the San Diego County Regional Airport Authority acknowledges receipt of an application for a determination of consistency for the project described above. This project is located within the Airport Influence Area (AlA) for the McClellan-Palomar Airport --Airport Land Use Compatibility Plan (ALUCP). ALUC staff has reviewed your application and accompanying materials and has determined that it meets our requirements to complete a consistency determination. ALUC staff will proceed with review of the project and report its findings to the Airport Authority Board, acting as the ALUC, to issue a determination of consistency with the ALUCP within 60 days of the date of this letter. You will receive notice of the Airport Authority Board hearing which will consider your project. If you have any questions, please contact Ed Gowens at (619) 400-2244 or egowens@san.org. ~-~ Sandi Sawa Manager, Airport Planning cc: Amy Gonzalez, SDCRAA, Director, Counsel Services Terry Barrie-Caltrans, Division of Aeronautics SAN DIEGO INTERNATIONAL AIRPORT IY)/1/u;t...~ ,l,J{J...C5}Jc '~ (~4')> C I T Y 0 F ~CARLSBAD Planning Department March 25, 2010 CEQA Tracking Center Department of Toxic Substances Control Attn: AI Shami, Project Manager 1001 I Street, 22nd Floor, M.S. 22-2 Sacramento, CA 95814 0 FILE COPY www.carlsbadca.gov SUBJECT: RESPONSE TO DTSC COMMENTS (SCH#2010021061)-GPA 06-09/ZC 06-08/SP 203(D)/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMP 07-02- MUROYA SUBDIVISION-MITIGATED NEGATIVE DECLARATION Dear Mr. Shami, Thank you for your comment letter dated March 17, 2010 pertaining to the Mitigated Negative Declaration (MND) that was prepared for the proposed Muroya Subdivision project located on a lot (APN:215-040-03) north of Aviara Parkway, south of Corte Orchidia, east of Towhee Lane, and west of Black Rail Road in the City of Carlsbad. City staff has evaluated the subject agricultural property with respect to the historic release of hazardous wastes/substances. Specifically, the applicant has provided to the City a Phase I and sul:)sequent Phase II Environmental Site Assessment (April 2006) by Dudek Environmental and Engineering, a Geotechnical Investigation Report by Geocon, Inc. (Project No. 07671-52-01, July 14, 2009), as well as Biological Resource Study and a Cultural Assessment Study, Drainage Study that staff referenced in the preparation of the Mitigated Negative Declaration for this project. The project has been assessed for all potentially significant impacts through the MND and all identified impacts have been mitigated to a less than significant level. A review of the above mentioned studies enabled City staff to conclude in the MND that the project does not have any hazardous wastes/substances on site nor are any expected during the grading and construction phases. For your convenience staff has responded below to each of the comment listed in your letter: Comment #1 -The NO should indentify and determine whether current or historic uses at the project area may have resulted in any release of hazardous wastes/substances. Reply -The applicant completed a Phase I Environmental Site Assessment and a Phase II Site As~essment (April 2006) for the project by Dudek Environmental and Engineering. The studies identified and assessed any hazardous wastes or substances. Comment #2 -The document states that the (M)ND would identify any known or potentially co11taminated sites within the proposed project area. For all identified sites, the (M)ND should evah,Jate whether conditions at the site may pose a threat to human health or the environment. Reply -The applicant completed a Phase I Environmental Site Assessment and a Phase II Site Assessment (April 2006) for the project by Dudek Environmental and Engineering. The Phase I study includes a section (pages 9-12) of "Public Agency Recort;:js Search Review" which includes all of the regulatory agency data bases, among many others, presented in your comment letter. Comment #3 -The (M)ND should indentify the mechanism to initiate any required investigation - and/or remediation for any site that may be contaminated, and the government agency to provide 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T (760) 602-4600 F (760) 602-8559 '-"' ...._,. GPA 06-09/ZC 06-08/SP 203(0)/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMP 07-02-MUROYA SUBDIVISION March 25, 2010 Pa e 2 appropriate regulatory oversight. If hazardous materials ~or wastes were stored at the site, an environmental assessment should be conducted to determine if a release has occurred. Reply-A Phase I and II Environmental Site Assessment was prepared for the project property by Dudek Engineering and Environmental (April 2006). The Phase 1 Environmental Site·Assessment identified a 500-gallon aboveground fuel storage tank and pesticide use during the past agricultural activities as potential concerns, and recommended a Phase II study be done so that soil samples could be investigated for hazardous materials. As part of the Phase II Environmental Site Assessment, Dudek collected five different soil samples at two locations adjacent to the aboveground storage tank for petroleum hydrocarbons (TPH). None of the soil samples had detectable concentrations of TPH diesel. One of the samples, a surface sample taken from underneath the nozzle of the fuel storage tank had detectable amounts of hydrocarbons in the motor oil range. There are no specified action levels for motor oil hydrocarbons so the report recommendation is for the visibly stained soil to be dug out and properly disposed of prior to any grading for the project. Dudek also collected eight soil samples from throughout the nursery site for pesticides analysis. Laboratory test results reported small concentrations of organochlorine pesticides in all eight of the samples. The US EPA Region IX has published Preliminary Remediation Goals (PRGs) and the California EPA has published the California Human Health Screening Levels (CHHSLs). Both the EPA PRGs and CAUEPA CHHSLs have a set base which allows for residential development. The report demonstrates that none of the eight samples contaired. concentrations greater than the US EPA Region IX Residential PRGs or CAUEPA Residential CHHSLs. Comment #4 -The project construction may require soil excavation and soil filling in certain areas. Appropriate sampling is required prior to disposal of the excavated soil. If soil is contaminated; properly dispose of it rather than placing it in another location. Reply -The Phase II Environmental Site Assessments prepared for the project property by Dudek Engineering and Environmental (April 2006) concludes that the site doesn't contain contaminated soils which require excavation and removal. Comment #5 -Human health and the environment of sensitive receptors should be protected during the construction or demolition activities. A study of the site overseen by the appropriate government agency might have to be conducted to determine if there are, have been, or will be any releases of hazardous materials that may pose a risk to human health or the environment. Reply -The Phase I Environmental Site Assessment also recommends that the existing house and maintenance building be analyzed for asbestos and lead based paint prior to any demolition, which will be incorporated into the conditions of approval. The existing house is proposed to remain. By following the recommendations contained within the referenced report, the site is suitable for the proposed project, and exposure of people to hazardous materials is considered to be less than significant. Comment #6 -If during construction/demolition of the project, soil and/or groundwater contamination is suspected,-construction/demolition in the area should cease and appropriate health and safety procedures should be implemented. If it is determined that contaminated soil and/or groundwater exists, the (M)ND should identify how any required investigation and/or remediation will be conducted, and the appropriate government agency to provide regulatory oversight. Reply -The project has provided a Phase I and Phase II Environmental Site Assessment (April _ 2006) by Dudek Environmental and Engineering, a Geotechnical Investigation Report by Geocon, Inc; (Project No. 07671-52-01, July 14, 2009), as well as several other studies which concur that no GPA 06-09/ZC 06-08/SP 2cC)/LCPA 06-09/CT 06-27/CP 06-19/C06-32/HDP 06-10/HMP 07-02-MUROYA SUBDIVISION March 25, 2010 Pa e 3 hazardous waste are present on site or are likely to be found on site. The project also involves grading operations and construction activity for the development of single-family homes. During the construction phases of the proposed project, construction equipment and materials typically associated with land development (i.e. petroleum products, paint, oils and solvents) will be transported and used onsite. Upon completion of construction of the project, some use of hazardous cleaning products on the site may occur. Other than during this construction phase, the project will not routinely utilize hazardous substances or materials. All transport, handling, use, and disposal of any cleaning substances will comply with all federal, state, and local laws regulating the management and use of such materials. No extraordinary risk of accidental explosion or the release of hazardous substances is anticipated with construction, development, and implementation or operation of the proposed project. It is concluded that the routine amount of hazardous materials utilized during the construction period is riot significant, and therefore the impact to the public or the environment through the routine transport, use, or disposal of hazardous materials is considered to be less that significant. Comment #7 -If weed abatement occurred, onsite soils may contain on-site residue. If so, proper investigation and remedial actions, if necessary, should be conducted at the site prior to construction of the project. Reply -The project has provided a Phase I and Phase II Environmental Site Assessment (April 2006) by Dudek Environmental and Engineering, a Geotechnical Investigation Report by Geocon, Inc. (Project No. 07671-52-01, July 14, 2009), as well as several other studies which concur that no hazardous waste are present on site or are likely to be found on site. Comment #8 -If it is determined that hazardous wastes are, or will be generated by the proposed operation, the wastes must be managed in accordance with the California Hazardous Waste Control Law and the Hazardous Waste Control Regulations. Reply -The project has provided a Phase I and Phase II Environmental Site Assessment (April 2006) by Dudek Environmental and Engineering, a Geotechnical Investigation Report by Geocon, Inc. (Project No. 07671-52-01, July 14, 2009), as well as several other studies which concur that no hazardous waste are present on site or are likely to be found on site. In light of the Phase I and Phase II Environmental Site Assessment studies referenced in the MND, it can be concluded that the MND adequately addresses and mitigates for potential of hazardous waste impacts. If you have any further questions, or wish to meet, please do not hesitate to contact me at (760) 602-4631. Sincerely, C[L DAN HALVERSON Assistant Planner DH:sm c: Jack Henthorn & Associates, Attn: Jack Henthorn, PO Box 237, Carlsbad, CA 92018 Taylor Morrison of CA, LLC, Attn: April Tornillo, 15 Cushing, Irvine, CA 92618 Don Neu, Planning Director Chris DeCerbo, Team Leader File Copy -- Department of Toxic Substances Control Linda S. Adams Secretary for Environmental Protection March 17,2010 Mr. Dan Halverson City of Carlsbad 1635 Faraday Avenue Carlsbad, California 92008 Maziar Movassaghi, Acting Director 5796 Corporate Avenue Cypress, California 90630 Arnold Schwarzenegger CITY OF CARLSBADovernor MAR 2 2 2010 Community & ECOil()l1lic Development Department DRAFT MITIGATED NEGATIVE DECLARATION (NO) FOR MUROYA SUBDIVISION (SCH# 2010021061) Dear Mr. Halverson: The Department of Toxic Substances Control (DTSC) has received your submitted document for the above-mentioned project. As stated in your document: "The proposed project involves a General Plan Amendment (GPA), Zone Change (ZC), Local program Amendment (LCPA), Specific Plan Amendment (SPA), Tentative Tract map (CT), Condominium Permit (CP) Coastal Development Permit (COP), Hillside Development Permit (HOP), Habitat Management Plan Permit (HMPP) to allow for the subdivision and development of a 20.27 acre parcel (APN 215-04-03) located north of Aviara parkway, south of Corte Orchidia, east of Towee Lane, and west of Black Rail Road. The Parcel will be subdivided into five (5) separate lots. Lot 1 is approximately 6.3 acres in size and will contain 37 detached condominium units clustered in the northern and eastern portions of the lot. Lot 2 is 0.9 acres in size and is the site of the owners existing residence which will remain on this parcel. Lot 3 and 4 are 1.6 acres and 9.8 acres in size and will be open space lots. Lot 5 is a 0.7 acres size lot which will be developed as private road for common access to the 37 detached condominium units". Based on the review of the submitted document DTSC has the following comments: 1) The ND should identify and determine whether current or historic uses at the project area may have resulted in any release of hazardous wastes/substances. 2) The document states that the NO would identify any known or potentially contaminated sites within the proposed project area. For all identified sites, the NO should evaluate whether conditions at the site may pose a threat to human health or the environment. Following are the databases of some of the regulatory agencies: ® Printed on Recycled Paper Mr. Dan Halverson March 17, 2010 Page 2 ""' National Priorities List (NPL): A list maintained by the United States Environmental Protection Agency (U.S.EPA). • EnviroStor, a database primarily used by the California Department of Toxic Substances Control, at www. Envirostor.dtsc.ca.gov. """ Resource Conservation and Recovery Information System (RCRIS): A database of RCRA facilities that is maintained by U.S. EPA. 0 Comprehensive Environmental Response Compensation and Liability Information System (CERCUS): A database of CERCLA sites that is maintained by U.S.EPA. • Solid Waste Information System (SWIS): A database provided by the California Integrated Waste Management Board which consists of both open as well as closed and inactive solid waste disposal facilities and transfer stations. • GeoTracker: A List that is maintained by Regional Water Quality Control Boards. Local Counties and Cities maintain lists for hazardous substances cleanup sites and leaking underground storage tanks. The United States Army Corps of Engineers, 911 Wilshire Boulevard, Los Angeles, California, 90017, (213) 452-3908, maintains a list of Formerly Used Defense Sites (FUDS). 3) The NO should identify the mechanism to initiate any required investigation and/or remediation for any site that may be contaminated, and the government agency to provide appropriate regulatory oversight. If hazardous materials or wastes were stored at the site, an environmental assessment should be conducted to determine if a release has occurred. If so, further studies should be carried out to delineate the nature and extent of the contamination, and the potential threat to public health and/or the environment should be evaluated. It may be necessary to determine if an expedited response action is required to reduce existing or potential threats to public health or the environment. If no immediate threat exists, the final remedy should be implemented in compliance with state laws, regulations and policies. 4) The project construction may require soil excavation and soil filling in certain areas. Appropriate sampling is required prior to disposal of the excavated soil. If the soil is contaminated, properly dispose of it rather than placing it in another Mr. Dan Halverson March 17, 2010 Page 3 location. Land Disposal Restrictions (LDRs) may be applicable to these soils. Also, if the project proposes to import soil to backfill the areas excavated, proper sampling should be conducted to make sure that the imported soil is free of contamination. 5) Human health and the environment of sensitive receptors should be protected during the construction or demolition activities. A study of the site overseen by the appropriate government agency might have to be conducted to determine if there are, have been, or will be, any releases of hazardous materials that may pose a risk to human health or the environment. 6) If during construction/demolition of the project, soil and/or groundwater contamination is suspected, construction/demolition in the area should cease and appropriate health and safety procedures should be implemented. If it is determined that contaminated soil and/or groundwater exist, the NO should identify how any required investigation and/or remediation will be conducted, and the appropriate government agency to provide regulatory oversight. 7) If weed abatement occurred, onsite soils may contain herbicide residue. If so, proper investigation and remedial actions, if necessary, should be conducted at the site prior to construction of the project. 8) If it is determined that hazardous wastes are, or will be, generated by the proposed operations, the wastes must be managed in accordance with the California Hazardous Waste Control Law (California Health and Safety Code, Division 20, Chapter 6.5) and the Hazardous Waste Control Regulations (California Code of Regulations, Title 22, Division 4.5). If it is determined that hazardous wastes will be generated, the facility should also obtain a United States Environmental Protection Agency Identification Number by contacting (800) 618-6942. C~rtain hazardous waste treatment processes or hazardous materials, handling, storage or uses may require authorization from the local Certified Unified Program Agency (CUPA). Information about the requirement for authorization can be obtained by contacting your local CUPA. 9) DTSC can provide guidance for cleanup oversight through an Environmental Oversight Agreement (EOA) for government agencies that are not responsible parties, or a Voluntary Cleanup Agreement (VCA) for private parties. For additional information on the EOA or VCA, please see www.dtsc.ca.gov/SiteCieanup/Brownfields, or contact Ms. Maryam Tasnif- Abbasi, DTSC's Voluntary Cleanup Coordinator, at (714) 484-5489. Mr. Dan Halverson March 17, 2010 Page4 c If you have any questions regarding this letter, please contact me at (714) 484-5472 or at "ashami@DTSC.ca.gov". AI Shami Project Manager Brownfields and Environmental Restoration Program -Cypress cc: Governor's Office of Planning and Research State Clearinghouse P.O. Box 3044 Sacramento, California 95812-3044 state.clearinghouse@opr.ca.gov CEQA Tracking Center Department of Toxic Substances Control Office of Environmental Planning and Analysis 1001 I Street, 22nd Floor, M.S. 22-2 Sacramento, California 95814 ADelacr1 @dtsc.ca.gov CEQA#2830 (~4) CITY OF • CARLSBAD F\LE COPY Planning Department www.carlsbadca.gov March 16, 2010 Jack Henthorn & Associates Attn: Jack Henthorn PO Box 237 Carlsbad, CA 92018 SUBJECT: GPA 06-09/ZC 06-08/SP 203(0)/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06- 10/HMP 07-02-MUROYA SUBDIVISION The preliminary staff report for the above referenced project will be sent to you via email on Wednesday, March 24, 2010, after 8:00 a.m. This preliminary report will be discussed by staff at the Development Coordinating Committee (DCC) meeting which will be held on March 29, 2010. A twenty (20) minute appointment has been set aside for you at 9:00 AM. If you have any questions concerning your project you should attend the DCC meeting. It is necessary that you bring the following required information with you to this meeting or provide it to your planner prior to the meeting in order for your project to go forward to the Planning Commission: 1. Unmounted colored exhibit(s) of your site plan and elevations 2. A PDF of your colored site plan and elevations The colored exhibits must be submitted at this time to ensure review by the Planning Commission at their briefings. If the colored exhibits are not available for their review, your project could be rescheduled to a later time. The PDF of your colored site plan and elevations will be used in the presentation to the Planning Commission and the public at the Planning Commission Hearing. If you do not plan to attend this meeting, please make arrangements to have your colored exhibit(s) and the PDF here by the scheduled time above. Should you wish to use visual materials in your presentation to the Planning Commission, they should be submitted to the Planning Department no later than 12:00 p.m. on the day of a Regular Planning Commission Meeting. Digital materials will be placed on a computer in Council Chambers for public presentations. Please label all materials with the agenda item .number you are representing. Items submitted for viewing, including presentations/digital materials, will be included in the time limit maximum for speakers. All materials exhibited to the Planning Commission during the meeting (slides, maps, photos, etc.) are part of the public record and must be kept by the Planning Department for at least 60 days after final action on the matter. Your materials will be returned upon written request. If you need additional information Halverson at (760) 602-4631. Sincerely, Q_)'t DON NEU Planning Director DN:DH:sm C": Taylor Morrison of California, LLC, Attn: April Tornillo, 15 Cushing, Irvine, CA 92618 File Copy Project Engineer 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T (760) 602-4600 F (760) 602-8559 March 12, 2010 JACK HENTHORN & ASSOCIATES P.O. BOX237 CARLSBAD, CA. 92108 RE: MUROYA RESIDENTIAL DEVELOPMENT-REQUEST TO PURCHASE OFF-SITE AFFORDABLE HOUSING CREDITS Dear Jack: Thank you for your letter dated February 25, 2010 requesting staff support for the Muroya Residential Development to purchase housing credits in either the Villa Lorna or Cassia Heights Affordable Housing developments in order to satisfy the project's inclusionary housing requirement. The Carlsbad Housing Policy Team reviewed your request and met to discuss the proposal. On March 1, 2010, the Carlsbad Housing Policy Team (City Staff) agreed to support the purchase of credits for the Muroya Residential Development. If the developer receives approval to build 37 market rate units on the Muroya property, the developer will be required to purchase 7 credits. Staff will recommend approval of the credit purchase to the Planning Commission and City Council as a result of the Housing Policy Team's support. As a reminder, staff will recommend that the credit purchase agreement expire no more than two (2) years after project approval. If the credits have not been purchased and the building permits for the subject project are not issued before expiration of the term of the agreement, you will need to resubmit your request for reconsideration at that time. There is no guarantee at this time that an approval to purchase the credits will be extended beyond the two (2) year period. In addition, it is important to remind you that the credit price is subject to change. You will be required to pay the credit purchase price that is in effect at the time of purchase; the credit price is not set at this time or within the agreement. If you have any other questions regarding this matter, please contact my office at (760) 434-2935. ~~-r~ DEBBIE FOUNTAIN Housing and Redevelopment Director C: Project Planner-Dan Halverson 2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2397 • (760) 434-2810/2811 • FAX (760) 720-2037 <!} ,.-, - '-"' ~ Jack Henthorn & Associates P.O. Box 237 Carlsbad, California 92018-0237 (760) 438-4090 Fax (760) 438-0981 February 25, 2010 Ms. Deborah K Fountain Housing and Neighbmhood Services Director City of Carlsbad 2965 Roosevelt Street, Suite B Cadsbad, CA 92008-2389 Subject: Mul'oya Residential Development -Request to Purchase Off-site Affordable Housing Credits Dear Ms .. Fountain: This letter serves as a fotmal request by Taylor Monision Homes, Inc., acting on behalf of the property owners of the Muroya Property to satisfy their affordable housing obligations fot the Muroya Residential Development through the purchase of off-site affordable housing credits in the existing Villa Lorna combined housing development as permitted by CMC 21 .85 and City Council Policy 57. The Muroya residential ptoject ptoposes the construction of 37 single family detached condominium units on a 20 acre site located on the west side of Blacktail Road, in local facilities management zone 20.. The units are proposed to range from approximately 2100 to 2800 square feet, with an average projected sales price of approximately $700,000 .. This application has been in process since 2004 when a proposal for an attached residential pwject was ptesented to the Planning Department for preliminary review and was rejected. The project was presented again in 2006 with an on site affordable housing component and rejected as being incompatible with the surrounding development and land use designations. The latest 37 unit project was revised and presented to the City in late December of 2006 with a proposal to purchase credits under City Council policy 57 Due to design constJaints imposed by the Habitat Management Plan, the project was placed on hold pending Coastal Commission approval of the City's Planned Development Ordinance revisions The Coastal Commission approved the ordinance revisions and the project application was determined complete and is being scheduled for Planning Commission consideration in early April. The options that are available to a developer to satisfy his inclusionary housing obligations are: 1) constJuct affordable units on-site, 2) participate in an off-site combined inclusionary project within the southwest quadrant in accordance with the requirements set forth in Chapter 2185 of the Carlsbad Municipal Code and City Council 5927 Balfour Court, Ste .. 112 • Carlsbad, CA 92008 Policy 57 dated August 8, 1995, or 3) enter into an agreement with the City to purchase credits fiom the Villa Lorna Combined Inclusionary Housing Project in accordance with City Council Policy 58 dated Septembet 12, 1995 .. In the case of the Mw-oya Residential application, there are particular circumstances that warrant this project's pruticipation in the purchase of ctedits in the Villa Lorna combined affordable housing project, pwsuant to Council Policy 58 criteria Significant feasibility issues affect the ability to provide on site affordable units as discussed below.. • Given the small size of the project (37 total units) and the restricted sale prices associated with affordable units (approximately $200,000 based on providing a 1400 square foot two bedroom unit affordable at 80% AMI), it will NOT be possible to make the pr~ject profitable and economically feasible with on-site affordable units. • The pr~jected cost of land acquisition, cru1ying costs associated with the land, funding an open space endowment and improving the site on a 3 7 unit basis is in excess of $380,000 pet unit The cost of bringing a market tate unit to sale including pet mit fees, constmction and sales costs is approximately $21 0,000 .. This leaves approximately $110,000 or 18% per unit for contingency and pre tax profit, based on an average sales ptice of $700,000 • The construction of the 6 affordable units on-site at a cost of $536,000 per unit and a sales price of$200,000 would result in the ptojecfs mruket-rate units being required to subsidize the 6 affordable units by over $65,000 per market unit 01 nearly $2 .. 0 million dollars. This represents over 60% of the project's pre-tax profit and contingency funds .. • The developer cannot afford to build the affordable housing product on-site.. The pwchase of 6 credits in the Villa Lorna combined affordable housing pr~ject at a cost of approximately $300,000 will reduce the the projected pre-tax profit and contingency funds to approximately 17% and maintain the project's feasibility This request complies with City Ordinances and City Council policies previously adopted by the City Council.: Contribution to the existing off-site ptoject versus ptoviding 6 affordable units on-site will also result in increased public benefit by retwning funding currently tied up in the Villa Lorna project, for use in other affordable housing activities. In addition, the project will be completing the last remaining frontage improvements along the western fiuntage of Blacktail Road, providing unintenupted pedestrian access between Poinsettia Lane and A viara Parkway Please call if you need additional infoxmation or if we may be of any othet assistance We look forward to receiving your response to this request. Enclosure cc: Dan Halvorsen, Planning Department Aptil I omillo, 1 aylor Monison Homes, Inc .. Cit February 8, 2010 Jack Henthorn c/o Jack Henthorn & Associates P.O. Box 237 Carlsbad, CA 92018 FILE COPY ...;;.9·/0 of SUBJECT: GPA 06-09/ZC 06-08/SPA 2030/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/ HOP 06-10/ HMPP 07-02 -MUROYA SUBDIVISION -CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) APPLICABILITY/PROCESS DETERMINATION This is to advise you that after reviewing the application for the project referenced above, the City has determined that the following environmental review process (pursuant to CEQA) will be required for the .Project: · The project is subject to the provisions of CEQA. Based on the City's analysis of the proposed project, the following CEQA documentation/process is required for the project: A MITIGATED NEGATIVE DECLARATION (MND) will be prepared for the project pursuant to the provisions of CEQA. Please submit the Environmental Impact Assessment Fee of $1604.00 for the continued processing of the CEQA documentation. For additional information related to this CEQA applicability/process determination, please contact the project planner, Dan Halverson, at (760) 602-4631 or Daniel. Halverson@carlsbadca.gov Sincerely, 9;&,/lr DON NEU Planning Director DN:DH:It c: April Tornillo, Taylor Morrison of CA, LLC, 15 Cushing, Irvine, CA 92618 Chris DeCerbo, Team Leader Clyde Wickham, Project Engineer File Copy Data Entry 1635 FaradaY Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us ~ JC Henthorn & AssociateO P.O. Box 237 January 13, 2010 Dan Halverson City of Carlsbad Planning Department 1635 Faraday Avenue Carlsbad, CA 92018 Carlsbad, California 92018-0237 (760) 438-4090 Fax (760) 438-0981 RECEIVED JAN 1 3 2010 CITY OF CARLSBAD PLANNING DEPT / /' / ,/ SUBJECT: 4th REVIEW FOR GPA 06-09/ ZC 06-08/ SPA 2030/ LCPA 06-09/ CT A6-27/ CP 06-19/ CDP..,...06-32/ HOP Q.6-10/ HMPP 07-02 -MUROYA SUBDIVISION ..,.- Dear Dan, Enclosed is the response to comments from the fourth submittal letter dated December 24, 2009 for the Muroya project. At this time, we are providing four (4) complete sets of the revised development plans along with the specific responses so that the project can continue to be reviewed. If you would like to schedule a meeting to discuss this response letter or any of the attached items, please contact me at your convenience. JEH:wpc c: April Tornillo, Taylor Morrison of CA, LLC, 15 Cushing, Irvine, CA 92618 Chris DeCerbo, Team Leader Clyde Wickham, Project Engineer File Copy 5927 Balfour Court, Ste. 112 • Carlsbad, CA 92008 ISSUES OF CONCERN Planning: 1. On the Civil Plan, sheet 1, please revise General Note #9 to include all proposed lots. (i.e. Lots 1 &5 proposed density 5.3 dulac - 7 acresl37 units and Lot 2 proposed density 1.1 dulac-0.9 acresl1 unit. Planning Item 1 response: Modifications have been made to notes as requested and are reflected on the resubmitted plans 2. On the Civil Plan, please provide the lot coverage for proposed Lot 2, the existing residence. Planning Item 2 response: Engineering: Lot coverage has been added to proposed lot 2 to reflect the existing residence 1. The City has attached comments and corrections from a Geotechnical third party review. Please correct and resubmit the geotechnical report, or submit an addendum to address these comments. Engineering Item 1 Response: A detailed response to the third party review letter, prepared by GEOCON Incorporated, is enclosed with the resubmittal package. 2. The design speed for Street "A" is 25 mph. Please correct the profile design on sheet 4. Show compliance with design requirements identified in chapter 3 and 4 of the City's Engineering Standards. Engineering Item 2 Response: Street "A" profile design on sheet 4, has been modified to comply with 25 mph design requirements identified in chapter 3 and 4 of the City's Engineering Standards. c 3. The proposed Stormfilter unit and filter inserts shown on sheet 3 and sheet 5 is acceptable as a filtration unit for the anticipated development of the north half of this project. The southern portion of the project has no structural filtration device as identified on sheet 3, please revise. Engineering Item 3 Response: The Storm Water Management Plan proposes a treatment train on the southerly outfall from the property including Catch Basin Inlet Filters and an Extended Detention Basin. The Extended Detention Basin will provide pollutant removal efficiencies in accordance with the Regional Permit Requirements. Please see Section 7.3 of the SWMP for sizing calculations. We are in compliance with the R WQCB permit for the southerly portion of the project as well as the northerly portion. 4 The project is a Priority Project and must incorporate Low Impact Design (LID) features per Engineering Standards Volume 4, Section 2.3.3.1 and Appendix B. This will be a condition of approval that could require redesign or modification Engineering Item 4 Response: Landscaping: REPEAT COMMENTS 1-11 Completed We concur that this can be a Condition of approval requiring LID. We are proposing many LID measures in our current SWMP. Though we acknowledge that LID requirements and technology are both moving targets, we are comfortable that we can achieve compliance without redesign of the site plan. 9A. The combination view fence/block wall appears to be within the sight line. Please resolve. 12. RETURN REDLINES and provide 2 copies of only the concept plans on the next submittal. NEW COMMENTS 1 B. Clarify that large shrubs will not be planted in zone 1 fire suppression areas. 28. Artemisia is a high fuel species. Please provide a low fuel species where used within the fire suppression zone. Landscaping items 9 A, 12 and new comments 1A and 1B: These comments are addressed in the enclosed letter from GMP dated January 7, 2012, and are reflected in the revised Landscape plan sets. City December 24, 2009 Jack Henthorn c/o Jack Henthorn & Associates P.O. Box 237 Carlsbad, CA 92018 FILE COPY J~·,LI· 09 of Carlsbad 1 #IF 1 ;t; 1 1; t· 1 •14. t t a 1;. 14; 1 1 SUBJECT: 4th REVIEW FOR GPA 06-09/ ZC 06-08/ SPA 2030/ LCPA 06-09/ CT 06-27/ CP 06-19/ COP 06-32/ HOP 06-10/ HMPP 07-02-MUROYA SUBDIVISION Dear Jack, The Planning Department has reviewed your fourth submittal dated November 10, 2009 for the Muroya project. Please note that the application is still considered incomplete due to the legislative actions that are associated with this project. Furthermore, there are issues left to resolve before the project can be scheduled for a public hearing (please see attached list). At this time, the City asks that you provide four (4) complete sets of the revised development plans so that the project can continue to be reviewed. If you would like to schedule a meeting to discuss this letter or your application, please contact me at the phone number listed below. You may also contact each commenting department individually as follows: • Planning Department comments: Dan Halverson, Assistant Planner, at (760) 602-4631 or Daniei.Halverson@carlsbadca.gov • Engineering Department comments: Clyde Wickham, Associate Engineer-Engineering Development Services, at (760) 602-2742 or Clyde.Wickham@carlsbadca.gov. • Fire Department comments: James Weigand, Fire Inspections, at (760) 602-4661. Sincerely, dw\li{J CHRIS OeCerbo Principal Planner CD:DH:It c: April Tornillo, Taylor Morrison of CA, LLC, 15 Cushing, Irvine, CA 92618 Chris DeCerbo, Team Leader Clyde Wickham, Project Engineer Michael Elliott, PELA James Weigand, Fire Inspection File Copy Data Entry 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us (i} GPA 06-091 ZC 06-081 SPA2'Q3DI LCPA 06-091 CT 06-271 CP 06-19I~P 06-32/ HOP 06-10/ HMPP 07-02-MUROYA SUBDIVISION December 24, 2009 Pa e 2 ISSUES OF CONCERN Planning: 1. On the Civil Plan, sheet 1, please revise General Note #9 to include all proposed lots (i.e. Lots 1 &5 proposed density 5.3 dulac - 7 acres/37 units and Lot 2 proposed density 1.1 dulac-0.9 acresl1 unit). 2. On the Civil Plan, please provide the lot coverage for proposed Lot 2, the existing residence. Engineering: 1. The City has attached comments and corrections from a Geotechnical third party review. Please correct and resubmit the geotechnical report, or submit an addendum to address these comments. 2. The design speed for Street "A" is 25 mph. Please correct the profile design on sheet 4. Show compliance with design requirements identified in chapter 3 and 4 of the City's Engineering Standards. 3. The proposed Stormfilter unit and filter inserts shown on sheet 3 and sheet 5 is acceptable as a filtration unit for the anticipated development of the north half of this · project. The southern portion of the project has no structural filtration device as identified on sheet 3, please revise. 4. . The project is a Priority Project and must incorporate Low Impact Design (LID) features per Engineering Standards Volume 4, Section 2.3.3.1 and Appendix B. This will be a condition of approval that could require redesign or modification. Landscaping: REPEAT COMMENTS 1-11 Completed 9A. The combination view fence/block wall appears to be within the sight line. Please resolve. 12. RETURN REDLINES and provide 2 copies of only the concept plans on the next submittal. NEW COMMENTS 1 B. Clarify that large stlrubs will not be planted in zone 1 fire suppression areas. 2B. Artemisia is a high fuel species. Please provide a low fuel species where used within the fire suppression zone. GEOCON INCORPORATED Project No. 07671-52-01 November 3, 2009 Taylor Woodrow Homes Incorporated 16745 West Bernardo Drive, Suite 140 San Diego, California 92127 Attention: Subject: Ms. April Tornillo MUROY A PROPERTY CARLSBAD, CALIFORNIA GEOTECHNICAL DESIGN CRITERIA FOR DRAINAGE SWALES Dear Ms. Tornillo: GEOTECHNICAl CONSUlTANTS In accordance with your request, this letter has been prepared to provide our opinion regarding the precise grading of sideyard swales along residential units within the subject development. If drainage swales are planned for a location within 5 feet from the structure perimeter, the footings should be deepened to accommodate minimum foundation embedment. We recommend that the location of the deepened footing be shown on the plot plans. We understand that Geocon Incorporated will be provided copies of the plot plans and will observe in the field that the deepened footings are properly excavated during the foundation excavation observation. Should you have any questions regarding this letter, or if we may be of further service, please contact the undersigned at your convenience. Very truly yours, ]b(~ORATID Shawn Weedon · GE2714 AS:dmc (2) (2/del) Addressee Hunsaker & Associates Attention: Ms. Marybeth Murray 6960 Flanders Drive B Son Diego, California 92121-297 4 B Telephone (858) 558-6900 B Fox ( 858) 558-6159 JO Henthorn & AssociateO P.O. Box 237 Carlsbad, California 92018-0237 November 2, 2009 Jason Goff, Associate Planner City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 438-4090 Fax (760) 438-0981 RECEIV£0 ~·!'\I 1 0 2009 CITY OF CARLSBAD PLANNING DEPT Subject: Muroya Subdivision-Re-submittal Package for CT 06-27/CP 06-19/CDP 06-32/ HDP 06-10/HMPP 07-02/GPA 06-09/ZC 06-08 Dear Mr. Goff: Enclosed is there-submittal package for the proposed Muroya Subdivision. The project has been revised to reflect the issues of concern identified in the City Planning Department letter dated September 15, 2009. Please refer to the transmittal letter for a listing of specific items contained in this re-submittal. PLANNING ISSUES OF CONCERN Issue 1 -1.c. General Plan/Zoning/LCP revisions All documents have been modified to incorporate the requested changes related to General Plan, Zoning and Local Coastal Program Amendments. Update documents are provided with this re-submittal. ~~sue 2 -General Plan/Zoning/LCP exhibits Updated General Plan , Zone Change and Local Coastal Program Amendment exhibits reflecting comments 1 -1.c. are included in this re-submittal. 1 ,.--Issue 3 -Zone 20 Specific Plan r Text revisions to Planning Area E and modifications to exhibits 3, 7 and 10 as required to amend the Zone 20 Specific Plan to reflect changes requested in items 1 -l.c. are included. Issue 4-Setbacks/coverage lot 2 Setbacks and lot coverage info has been added to the plan to confirm conditions on Lot 2 5927 Balfour Court, Ste. 112 • Carlsbad, CA 92008 Issue 5 -JHA contact info Contact information for JHA has been modified Issue 6 -Lot summary table The lot summary table has been updated; plan and table are consistent. Issue 7 -Loggia setbacks The loggias have been eliminated on units 13 and 14 and the setback dimensions have been revised. Item 8 -Hillside development regulations The submittal contains four constraints map sheets (Sheets 4 thru 7) to clearly distinguish Growth Management Constraints from Hillside and Coastal Constraints. • The HDP BIO/SLOPE ANALYSIS map (sheet 4 of 7) addresses items required by the Growth Management Ordinance to be used in calculating the lot/unit yield based on net acreage and growth control point information. • The DUAL CRITERIA IMPACT ANALYSIS map (sheet 5 of7) delineates those areas with slope gradient in excess of 25%, habitat types and grading limits. • The 40% SLOPES OVERLAY ON GEOLOGY map (sheet 6 of 7) delineates those areas that are natural and manufactured slope areas with gradients in excess of 40% in relationship to the proposed limits of grading. • The 40% SLOPES OVERLAY ON BIO map (sheet 7 of 7) is provided to further delineate natural and manufactured slope areas with gradients in excess of 40%. The Hillside Development Mapping delineates slope areas and categories pursuant to 21.95.110 and 21.203.040.A. It identifies all natural and manufactured slopes within each of the City Hillside Development Ordinance required categories. The project design includes the grading of 425 square feet, or 0.3% (three tenths of one percent), ofthe 2.99 acres of natural slope areas over forty percent gradient found on site. Justification for this impact is included in the discussion of dual criteria impacts, below. The project also proposes the grading of previously manufactured slopes over Forty Percent Gradients as defined in 21.95.120.C. The impacted slope area is not located along a perimeter property line and as such, the slope standards contained in 21.95.120 do not apply. The following findings are offered to demonstrate compliance with the Hillside Development Ordinance. 1. Hillside conditions have been properly identified on the constraints map which shows existing and proposed conditions and slope percentages. 2. Undevelopable areas of the project have been properly identified on the Hillside Development Constraints Map prepared in compliance with 21.95.110 3. The project complies with the purpose and intent of the Hillside Development Permit in that : a. Implements the goals and obtjective of the land use and open space conservation elements of the General Plan, the zone 20 specific plan, the Habitat Management Plan and the City's certified Local Coastal Program. b. Hillside conditions have been properly identified and incorporated in to the planning for the area by limiting development to areas previously disturbed by agricultural operations and eliminating the need to access flatter areas of the site to the southwest of the SDG&E easement c. The project's total grading quantity of 3005 cubic yards per acre is within the acceptable volume range of the Hillside Development Ordinance. d. The project design preserves and enhances the aesthetic quality by incorporating slope edge setbacks, concentrating development on the flatter agricultural areas of the site eliminating the need to grade natural slope areas to provide access to flatter developable areas and replicating the natural slope areas by employing contour grading and natural landscaping into the design of the remediated slope areas e. The alteration of natural hillsides has been minimized and has been designed to protect downstream areas as shown in the hydrology and storm water management plans. Impact to natural resource areas, wildlife habitats or native vegetation areas are proposed to be mitigated pursuant to the PHMP. All natural habitat will be placed in an open space easement, encumbered by a restrictive covenant with perpetual management activity funded through a non wasting endowment. f. The proposed encroachment into slopes of twenty five percent and over will result in the preservation of natural habitats pursuant to the City Habitat Management Plan that would not otherwise be possible with strict adherence to the requirements of21.95.120 A and B. c Item 9 -Coastal Resource Protection Overlay Zone The mapping produced to comply with Section 21.95.110 also meets the requirements associated with 21.203.040.A of the Coastal Resource Protection Overlay Zone. Supplemental exhibits are included. The project has been designed to minimize impacts to natural slope (dual criteria) areas exceeding 25% grade. The proposed project design would impact 0.36 acres, or 6.36% of total on-site dual criteria slope areas. The design complies with the City's habitat management plan in that it conserves flat areas where construction of access routes would have resulted in additional disturbance to habitat and core and linkage areas. Preservation levels provided by the current design could not have been achieved by strict adherence to the requirements of21.203.040.Al.a. & b. The HMP contains standards that are intended to direct development to the existing disturbed areas to the maximum extent feasible, limit impacts to native vegetation and establish viable core and linkage areas as designated in the HMP. Specifically, the subject property (APN 215 040 03) is required to cluster development on disturbed areas to the maximum extent feasible. A maximum 10% impact on CSS and SMC is allowed for access purposes. The site design eliminates any circulation related impact to CSS and SMC. A supplemental exhibit is included demonstrating how the design contiributes ot he establishment of planned core and linkage areas. The project proposes limited grading of dual criteria slope areas (0.36 acres or 6.36% of the total on-site acreage). This clustered design eliminates the need to disturb additional Southern Mixed Chaparral to gain access to flatter areas of the site to achieve a viable level of development. Section 21.203.040 A.l.c provides for removal of native vegetation to create firebreaks.. Supplemental exhibits are included as requested and previously noted. The following findings are offered to demonstrate compliance with the Coastal Resource Protection Overlay Zone, CMC 21.203.040.A.3: 1. A soils investigation has been completed and 75 year slope stability finding is made in the supplemental letter included with this submittal. 2. The grading of the anomalous slope area is essential to the development intent and design and implements the provisions of the Zone 20 specific plan and preserves those areas designated as Specific Plan open space (Zone 20 Specific Plan Exhibit 1 0). The design of the site 3. The slope disturbance will not result in substantial damage or alteration to major wildlife habitat or native vegetation areas in that mitigation is being proposed pursuant to the bio technical report to insure that any potential impacts are mitigated in accordance with the provisions of the HMP. Items 10, 11, 12, 13 and 15-Miscellaneous Landscape plan comments These items have been addressed in the revised landscape plans and letter from GMP provided in this re-submittal package Item 14 -Building Elevation Design Elements The requested updated matrix is included. Items 16, 17, 18, 19, 20 and 22-Biological Resources Technical Report!HMP Compliance These items have been addressed in the revised Biological Resources Technical Report included with this re-submittal. Item 21 -Mitigation for 20 ft. upland habitat buffer The BRTR has been updated to include mitigation for the entire 20ft upland habitat buffer in accordance with HMP-Table 11 (D-113)-Mitigation Ratios for Impacts to HMP Habitats. The buffer design includes an area (approximately 186 feet or 12% of the total length) where the proposed buffer area, varying from 20 to 40 feet in width is located in a restricted Home Owners Association common area lot within the proposed grading limits. The modified buffer area is proposed to be landscaped with native plants that will achieve the purposes of the buffer as defined in the Carlsbad HMP. The area will also be covered by a restriction prohibiting development, grading or alterations including clearing of vegetation except for fuel modification associated with brush management zone 3. The proposed design will reduce impacts to Southern Maritime Chaparral habitat by preserving over 7200 square feet of the highest value upland natural habitat in the Coastal Zone. This area is proposed to be included within the habitat preservation lot where it will be actively managed and further restricted by the SDG&E NCCP. Engineering Item 1 -Remedial quantity calculations The removal quantity estimate has been updated based on geotechnical report information. Item 2 -Retaining wall details Retaining wall details have been added to the typical lot grading details on Sheet 2. Item 3 -Sideyard drainage Details on sheet 3 have been modified per discussions between engineering staff and representatives of Hunsaker and Associates. The requested Geotechnical letter is provided as a part of this re-submittal package. Issue 4-Geotechnical3rd party review Two copies of the Geotechnical report were previously submitted along with a check for the cost of 3rd party review. Issue 5-Street "A" design speed Private Street "A" is designed with a 25 M.P.H. speed with the exception of the crest vertical curve at the project entry. The calculated vertical curve length for 25 M. P. H. with a 6.5% grade differential is 96'. At 20M. P. H. the curve length is calculated to be 46'. The crest vertical curve was designed at 20 M.P.H. with a 60' vertical curve in order to push back the PVI 20' to allow the entire site to drop by approximately 2' to reduce overall grading, earthwork and retaining walls. The justification points for this requested reduction in design speed at this location are: 1) this location is at the entry and exit of the site where cars will be slowing to turn in or to stop at the intersection; 2) there will be a stop sign at the intersection and the required sight distance of 150' extends well beyond the stopping point; and 3) Street "A" is a private street. Issue 6-Nightshade Road storm drain easement/capacity Reference information for the public storm drain easement on Nightshade Road has been added to the plan. Per discussion between Dave Hammar and Clyde Wickham, capacity issues have been resolved. This project will not increase flows leaving the site. Issue 7-Downstream storm drain capacity. The drainage report verifies that the capacity of the existing connection point is adequate to convey the Muroya Project site drainage. Per discussion between Dave Hammar and Clyde Wickham, further downstream analysis is not required. Again, this project will not increase flows leaving the site. Issue 8 -Street light verification. The location of existing street lights within the project's immediate vicinity has been verified. c If you have any questions or need additional information, please contact me at your convenience, at (760) 438-4090, extension 225, or by e-mail, at henthorn@jhenthorn.com. cc: April Tornillo, Taylor Morrison Anita Hayworth, Dudek & Associates Chuck Cater, Hunsaker & Associates Marybeth Murray, Hunsaker & Associates Rob Streza, GMP, Inc. Roy Capitan, Roberty Ridley Architects .. .~ , ...••. ,\ '-" ·.....,; Mr. Jason Goff September 11,2009 City of Carlsbad Page 1 of 5 Muroya -GPA 06-09/ ZC 06-08/ LCPA 06-09/ CT 06-27/ CP 06-19/ CDP 06-32/ HDP 06-10/ HMPP07-02 3rd Review Comments Response Letter GMP# 06-152-00 October 22, 2009 Mr. Jason Goff Associate Planner City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008-7314 Re: Muroya-GPA 06-09/ ZC 06-08/ LCPA 06-09/ CT 06-27/ CP 06-19/ CDP 06-32/ HDP 06- 10/ HMPP 07-02 3rd Review Comments Response Letter GMP# 06-152-00 Dear Mr. Goff: In response to the 3rd review comments for the above-referenced project, the following are our responses: COMMENT LETTER (9/15/09) Planning Comment 10: (REPEAT COMMENT) Landscape. Include a detail of proposed retaining walls. Any retaining walls that are facing the street or are visible from the interior of the project or public right-of-way should include a decorative type cap. The plantable wall must also include an irrigation detail. The plantable wall detail has been provided as requested in the June 23, 2007 issues letter. However, the details of the other retaining walls as requested have not. Please provide details of these walls showing consistency with the above request and also showing consistency with design features of the other decorative walls provided throughout the project. Response 10: A typical retaining wall detail has been added, see detail G sheet 4. Comment 11: Landscape Plans (Sheet 2) -The 5,236 sq. ft. of grassy play area does not fully meet the 75% active recreational component. In order for the grassy play area to count for the 75% active recreational component by itself, it will need to be increased in size to 5,550 sq. ft. with the minimum 50 ft. dimension (37 units x 200 sq. ft. per unit= 7,400 sq. ft. x .75 = 5,500 sq. ft.). However, the plans could remain as similarly proposed with the addition of another active recreational component chosen from the list, such as a children's playground equipment added to the adjacent turf area, etc. Please revise. Response 11: The active recreation area has been redesigned to be 5,614 sq.ft, see sheet 2. Comment 12: Please revise the Landscape Plan to include visitor parking space P-15. . ' ~ ,..,......, '--"' ..._, Mr. Jason Goff September 11, 2009 City of Carlsbad Page 2 of 5 Muroya -GPA 06-09/ ZC 06-08/ LCPA 06-09/ CT 06-27/ CP 06-19/ CDP 06-32/ HDP 06-10/ HMPP07-02 3rct Review Comments Response Letter GMP# 06-152-00 Response~·· Revised. Comment 13: Please provide pedestrian scaled landscape lighting within the recreational areas and walkways to provide a safe walkable environment. This, in addition to the proposed street lights, will further fulfill the intent of the Planned Development Regulations, Table C (Section C.1 0 -Lighting). Respons~: (5) light beacons (low ground mounted light fu:tures) have been provided along the pathway. Additional lighting is provided to the area by the street light in front of Lot 32. See sheet 2. Comment 15: Unless you can show that it 1s not an invasive species, please remove Pennisetum alopecuroides. Response U:/Removed, see sheet 1 a. Landscaping (PELA) REPEAT COMMENTS Comment 4: All slopes which have been graded or disturbed, including "natural slopes", must meet the slope planting requirements. It does not appear that groundcover and shrub planting requirements have been met on "natural slopes". 3rct Review: See NEW COMMENTS 2A, 3A, and 4A. Address all areas and address all required standards. Response 4: On 10122109, I clarified with Michael Elliott that the notes on sheets 1 and 1a would be edited per the redlines in order to address this comment. Comment 8: Fire Zone A2, B2 and A3 must have permanent irrigation. The design must provide for head to head coverage. 3rct Review: Please revise the note to clearly indicate complete irrigation of all planted areas. Fire suppression zones A1, A2, A3, B1 and B2 along with any planted areas require irrigation. Response 8: On 10122109, I clarified with Michael Elliott that the note on sheet 1 would be edited per the redlines in order to address this comment. NEW COMMENTS Comment 1A: Please address landscaping of all off-site graded areas. Response 1A: Landscape has been provided to all off-site graded areas, see sheet 1. Comment 2A: Please revise note to indicate that plantings are to meet slope revegetation requirement standards 1-4 except as modified by fire suppression requirements. Response 2A: The note on sheet 1a has been revised. •' '-' """"' Mr. Jason Goff September 11,2009 City of Carlsbad Page 3 of 5 Muroya -GPA 06-09/ ZC 06-08/ LCPA 06-09/ CT 06-27/ CP 06-19/ CDP 06-32/ HDP 06-10/ HMPP 07-02 3'd Review Comments Response Letter GMP# 06-152-00 Comment 3A: Please revise note to include plantings per slope revegetation requirements except as modified by fire suppression requirements. Response 3A: The notes on sheets 1 and 2 have been revised. Comment 4A: Trees and/or larger shrubs are required per standard number 4 of the slope revegetation requirements. Please insure all slope revegetation requirements are met except as modified by the fire suppression requirements. Check all notes on plans. Response 4A: The note has been revised, see sheet 1, all other notes have been checked for consistency. Comment 5A: Please insure landscaping is provided up to the back of the existing street landscape. Add landscaping as appropriate. Response 5A: Landscaping has been provided up to the existing street landscape as shown on sheet 1. Comment 6A: Please provide appropriate container plants in the plantable wall cells. Seed alone is not sufficient. Response 6A: 1 gallon container plants for the plantable wall are indicated on sheet la in the planting legend. Comment 7 A: Civil plans for the tentative map do not show a retaining wall in this location. Please coordinate plans or provide a copy of plans that show the wall for cross checking. Response 7A: Plans have been coordinated and the retaining wall is shown on the civil engineer's plans .. Comment 8A: Landscape elements over 30" in height (including planting measured at maturity) are not allowed at street comers within a triangular zone drawn from two points, 25' outward from the beginning of curves and end of curves. (See Appendix C4). The same height limitation applies at driveways 25' from edge of the apron outward along the curb then 45-degrees in toward the property. Please show and label the 25' sight line along with the 330' sight line and relocate wall/fence as required to be outside of these sight lines. Response SA: The triangular zone is drawn on the plans, see sheets 1 and 2a. A note has also been added to sheet 1 clarifying the intent to not provide any plant material over 30" in height within this area. Comment 9A: Please show the 330' sight line on the entry enlargement on sheet 2a. Insure no conflicts. Response 9A: The sight line is shown and a note has been added on sheet 2a to insure that there will be no conflicts. Comment 1 OA: Please add these trees with sizes to the legend. Response lOA: The trees as noted have been added to the planting legend on sheet la. •' '-' Mr. Jason Goff September 11,2009 City of Carlsbad Page 4 of 5 Muroya -GPA 06-09/ ZC 06-08/ LCPA 06-09/ CT 06-27/ CP 06-19/ CDP 06-32/ HDP 06-10/ HMPP 07-02 3rd Review Comments Response Letter GMP# 06-152-00 Comment 11A: Please add the palm symbol to the legend. Response IJA: The palm symbol has been added to the planting legend on sheet 1a. Comment 12A: There are several plants listed in the legend that are on the "Exotic Pest Plants of Greatest Ecological Concern in California" list (Schinus, Olea, Cistus). Please review all plants and modify as appropriate deleting invasive plant species. Response 12A: The Schinus and Cistus species have been removed. Correspondence with Michael Elliot on 10123109 indicated that the Olea species was okay to be used as long as it is fruitless. Comment 13A: The recreation area amenities have been revised deleting the pool area. Additional amenities are needed such as a play area (active), and additional picnic tables and barbecues, etc. (passive). Please review. Response 13A: Per Planning comment number 11, the design has been revised to provide an active play area of 5,614 sq. ft. which is in excess of the 5,500 sq. ft. required. Additional picnic areas are provided at the adjacent turf area and barbecues are provided at the overhead steel trellis in order to meet these requirements. Comment 14A: Plans have been revised deleting a recreation area and substituting a "future retention basin lot". Please explain the future retention basin. It is recommended that this area be returned to a recreation area .. Response 14A: The area is shown as turf, however future engineering may require that this lot serve as a retention basin. Comment 15A: Plans have been revised deleting a recreation area and substituting landscaped area. Landscaping shall be used to provide and enhance opportunities for outdoor recreation, relaxing, and eating. Although another recreation area is provided, recreational amenities are minimal. Please revise this area back to provide recreational activities. Response 15A: The recreational areas as provided meet the City requirements for the project per Planning comment #11. The area was redesigned because SDG&E did not want a totlot within their easement. Comment 16A: Please provide a revised colored recycled water use plan for review. The plan will be forwarded to Public Works Maintenance and Operations for review and any comments will be returned to the applicant. Response 16A: Provided. ..,,, '~ Mr. Jason Goff September 11,2009 City of Carlsbad Page 5 of 5 Muroya -GPA 06-09/ ZC 06-08/ LCPA 06-09/ CT 06-27/ CP 06-19/ CDP 06-32/ HDP 06-10/ HMPP 07-02 3rd Review Comments Response Letter GMP# 06-152-00 This response letter and the attached revised plans are being resubmitted to the City of Carlsbad to address the above review comments. Please do not hesitate to contact our office if you have any questions or require additional information for this project. Sincerely, Gillespie Moody Patterson, Inc. Rob Streza, RLA, ASLA, LEED AP Senior Project Manager G: 06-PROJECTS 06-152 Landarch Admin Muroya 10-22-09 Response letter-GMP,doc September 15, 2009 Jack Henthorn c City Jack Henthorn & Associates P.O. Box 237 Carlsbad, CA 92018 FILE COPY 9·15·0"1 of Carlsbad r:;aenun;t~i·JJ.t;Jai;.cg;a• SUBJECT: 3rd REVIEW FOR GPA 06-09/ ZC 06-08/ LCPA 06-09/ CT 06-27/ CP 06-19/ COP 06-32/ HOP 06-10/ HMPP 07-02-MUROYA SUBDIVISION Dear Jack, The Planning Department has reviewed your third submittal dated August 7, 2009 for the Muroya project. Please note that the application is still considered incomplete due to the legislative actions that are associated with this project. Furthermore, there are issues left to resolve before the project can be scheduled for a public hearing (please see attached list). At this time, the City asks that you provide five (5) complete sets of the revised development plans so that the project can continue to be reviewed. If you would like to schedule a meeting to discuss this letter or your application, please contact me at the phone number listed below. You may also contact each commenting department individually as follows: • Planning Department comments: Jason Goff, Associate Planner, at (760) 602-4643 or Jason. Goff@carlsbadca.gov. • Engineering Department comments: Clyde Wickham, Associate Engineer-Engineering Development Services, at (760) 602-2742 or Clyde.Wickham@carlsbadca.gov. • Fire Department comments: James Weigand, Fire Inspections, at (760) 602-4661. Sincerely, CY~ JASON GOFF Associate Planner JG:It c: April Tornillo, Taylor Morrison of CA, LLC, 15 Cushing, Irvine, CA 92618 Chris DeCerbo, Team Leader Clyde Wickham, Project Engineer Michael Elliott, PELA James Weigand, Fire Inspection File Copy Data Entry 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us {!) GPA 06-09/ZC 06-08/LC~6-09/CT 06-27/CP 06-19/CDP 06-320P 06-10/HMPP 07-02- MUROYA SUBDIVISION September 15, 2009 Pa e 2 ISSUES OF CONCERN Planning: 1. General Plan/Zoning/Local Coastal Program (LCP): Please revise any General Plan, Zoning, and LCP discussion(s)/note(s) on the plans/studies/exhibits to reflect the following: a. Proposed Lot 2, which contains the existing single-family house, will need to remain RLM (0-4 dulac), but will require a Zone Change from Limited Control (L-C) to One- Family Residential (R-1 ). The resultant density for this area will be 1.9 dulac (1 unit + 0.9 acres), which is consistent with the RLM density range of 1-4 dulac. A Local Coastal Program Amendment (LCPA) will also be required to change the LCP Zoning from L-C to R-1. b. Proposed Lots 1 and 5, which contains the proposed 37 unit condominium project, will require a General Plan Amendment from RLM (0-4 dulac) to RM (4-8 dulac) and a Zone Change from L-C to Residential Density-Multiple (RO-M). The resultant density for this area will be 5.3 dulac (37 units + 7 acres), which is consistent with the RM density range of 4-8 dulac. A LCPA will also be required to change the LCP Land Use designation from RLM to RM and the LCP Zoning designation from L-C to RO-M. c. Proposed Lots 3 and 4 will require a General Plan Amendment from RLM to Open Space (OS), and a Zone Change from L-C to OS. A LCPA will also be required to change the LCP Land Use designation from RLM to OS and the LCP Zoning designation from L-C to OS. Please be aware that because the total property will only yield 38 dwelling units, and 38 units are proposed, a condition will be added to the map restricting any future subdivision of any of these lots. 2. Please provide an updated General Plan Amendment, Zone Change & Local Coastal Program Amendment Map Exhibit addressing the issue item raised above. The previous exhibit was prepared by Jack Henthorn & Associates. 3. Specific Plan Amendment. The project will require an amendment to the Zone 20 Specific Plan in order to address the changes to land use and zoning that are being proposed for this site. 4. Please revise the site plan to include setbacks, lot coverage, lot width, etc. for the existing house on proposed Lot 2 in accordance with the proposed R-1 zone, so it can be determined that the lot dimensions and proposed orientation are not creating a nonconforming situation. 5. Civil Plan (Sheet 1) -Please revise the project representative's (Jack Henthorn & Associates) contact information as the address shown on the plans is no longer correct. ... GPA 06-09/ZC 06-08/LCF06-09/CT 06-27/CP 06-19/CDP 06-320P 06-10/HMPP 07-02- MUROYA SUBDIVISION September 15, 2009 Pa e 3 6. Civil Plans (Sheet 2) -Lot Summary Table: The lot area for Lots 1, 3, and 4 are inconsistent with the lot areas shown on Sheets 3 and 4. Please revise to be consistent. FYI: the calculations listed above in Issue Item No. 1 (a-c) were calculated using the lot area information shown on Sheets 3 and 4. 7. Civil Plan (Sheet 5): For Units 13 and 14, have the Loggia's been removed from the plan since the last plan review or was a layer turned off? If they've been removed, then please revise the setback dimension in the rear yard area so that it extends to the face of the building. · 8. Hillside Development (C.M.C. Ch. 21.95): Please note that pursuant to C.M.C. Section 21.95.120.8.1. development of natural slopes over 40% within the Coastal Zone, which have all of the following characteristics shall be considered undevelopable: a. A gradient of greater than 40%; and b. An elevation differential of greater than 15ft.; and c. A minimum area of 10,000 sq. ft.; and d. The slope comprises a prominent land form feature. Please note that grading is considered development per the definition of "Development (in the Coastal Zone)" (see C.M.C. Section 21.04.1 07), even if it is considered remedial. Furthermore, per the Exclusions section of the Hillside Development Regulations, grading of hillside areas with unusual geotechnical or soil conditions necessitating corrective work or significant amounts of grading is only allowed when outside of the Coastal Zone (see C.M.C. Section 21.95.130). There are two areas of the project proposing major grading of slopes over 40%, which appear to have all of these characteristics and thus would be considered undevelopable within the Coastal Zone. If it is believed otherwise, please prepare a supplemental exhibit, specifically demonstrating how this project complies with the above. Additional data in the form of revised exhibits iind/or new exhibits along with a detailed written explanation is required in order for staff to determine compliance and to write the necessary findings to support the approval of the Hillside Development Permit. 9. Coastal Resource Protection Overlay Zone (Ch. 21.203}: Approval of the Coastal Development Permit requires compliance with the Coastal Resource Protection Overlay Zone chapter. The project is proposing development of what is defined as "dual criteria slopes" in the form of project grading and fire suppression/brush management zones. Please demonstrate how this project is compliant with the provisions of C.M.C. Chapter 21.203. Additional data in the form of a supplemental exhibit along with a detailed written explanation is required in order for staff to determine compliance and to write the necessary findings to support the approval of the Coastal Development Permit. 10. (Repeat Comment) Landscape. Include a detail of proposed retaining walls. Any retaining walls that are facing the street or are visible from the interior of the project or public right-of-way should include a decorative type cap. The plantable wall must also include an irrigation detail. GPA 06-09/ZC 06-08/LCFC6-09/CT 06-27/CP 06-19/CDP 06-320P 06-10/HMPP 07-02- MUROYA SUBDIVISION September 15, 2009 Pa e4 The plantable wall detail has been provided as requested in the June 23, 2007 issues letter. However, the details of the other retaining walls as requested have not. Please provide details of these walls showing consistency with the above request and also showing consistency with design features of the other decorative walls provided throughout the project. 11. Landscape Plans (Sheet 2) -The 5,236 sq. ft. of grassy play area does not fully meet the 75% active recreational component. In order for grassy play area to count for the 75% active recreational component by itself, it will need to be increased in size to 5,550 sq. ft. With the minimum 50 ft. dimension (37 units X 200 sq. ft. per unit = 7,400 sq. ft. X .75 = 5,500 sq. ft.). However, the plans could remain as similarly proposed with the addition of another active recreational component chosen from the list, such as a children's playground equipment added to the adjacent turf area, etc. Please revise. 12. Please revise the Landscape Plan to include visitor parking space P-15. 13. Please provide pedestrian scaled landscape lighting within the recreational areas and walkways to provide a safe walkable environment. This, in addition to the proposed street lights, will further fulfill the intent of the Planned Development Regulations, Table C (Section C.1 0 -Lighting). 14. Please provide an updated "Building Elevation Design Elements" matrix to go along with the Policy 44 Compliance Tables. This exhibit has been prepared in the past by Jack Henthorn & Associates. 15. Unless you can show that it is not an invasive species, please remove Pennisetum a/opecuroides. Biological Resources Technical Report/HMP Compliance: 16. For HMP compliance purposes, all vegetation categories should fit within the Holland classification system, or at least be identified as Habitat Group A-F (HMP Table 11 ). a. "Baccharis scrub" should be identified as coastal sage scrub (Group D, if unoccupied by coastal California gnatcatcher) . b. "Leymus condensatus grassland" should be identified as "native grassland" (Group B). 17. There should be an exhibit showing an overlay of the property with Linkage F and the surrounding Core Areas since this is specifically mentioned in the Standards for properties within LFM Zone 20. 18. Please change the date of gnatcatcher breeding season from March 1 -August 15 to February 15 -August 30 to conform to the dates listed in the USFWS survey protocol. 19. Page 42, Paragraph 3, please add the following underlined text "A buffer zone of 500 feet will be established ... " 20. Page 42, Paragraph 5, please add the following underlined text "The open space area will need to be protected by a conservation easement, and a non-wasting endowment will need to be established for permanent management of the area." GPA 06-09/ZC 06-08/LCtV6-09/CT 06-27/CP 06-19/CDP 06-30P 06-10/HMPP 07-02- MUROYA SUBDIVISION September 15, 2009 Pa e 5 21. Please revise the report to include mitigation for the entire 20ft. upland habitat buffer in accordance with HMP -Table 11 (D-113) -Mitigation Ratios for Impacts to HMP Habitats. 22. Please revise Section 6.0 to provide a mitigation table for the impacts to "Disturbed Land" (Habitat Group F) and "Agricultural Land". For this project the report needs to clearly identify that the mitigation for the conversion of 7.90 acres of agricultural land will be subject to the Mello II Segment of the Local Coastal Program Agricultural Conversion Mitigation Fee, and not the in-lieu mitigation fees as established by the HMP .. The Agricultural Conversion Mitigation Fee is presently set at $10,000 per net converted acre of agricultural land. Please revise all portions of the report to address this. Engineering: Engineering Department staff has completed their 3rd review of the above-referenced project for application completeness. The application and plans submitted for this proposed project are from an Engineering perspective considered complete with issues to be resolved prior to support of the application(s). The following issues need to be resolved prior to resubmittal: 1. The remedial grading quantities shown on Sheet 1 state 36,000 CY "remedial remove and recompact" with 36,000 CY export. Will there be a total of 38,570 CY exported? Will there be 36,000 CY (structural/ clean fill) imported? Please review your estimated quantities and correct as necessary. I believe the proposed remedial grading is to remove 36,000 CY and export debris, and to import 36,000 CY of clean fill to recompact and stabilize. Adding these numbers to the remaining project quantities will resolve the conflict. 2. Please show the house on the uphill and downhill pad of the Plantable (sideyard) Area Detail on Sheet 2. Based upon the 5 ft. sideyard setback shown on (2) details of the same sheet, the proposed retaining wall would be located 2 ft. from the dwelling unit. The sideyard detail shows 3 ft. positive drainage from buildings. The proposed retaining wall should also be shown on (2) Typical Surface Drainage, Building Setback Details to the right and below on the same sheet as well. 3. The request to reduce drainage distance between sideyards should be supported by your Geotechnical Consultant. Typically this request is backed up with deepened footings, drainage system and possible curb to avoid saturation of building footings, retaining walls and fences between properties. The Geotechnical Report should support this request and should identify mitigation for the reduced positive drainage between buildings. An addendum will suffice to address these concerns and supply recommendations. 4. As we discussed, please submit two (2) copies of the Geotechnical Investigation and Tentative Map for a 3rd party review. I will send out a request for proposal as soon as I receive these copies. 5. The design speed for Street "A" is 25 mph. Please correct the profile design on Sheet 4. .. GPA 06-09/ZC 06-08/LCC6-09/CT 06-27/CP 06-19/CDP 06-30P 06-10/HMPP 07-02- MUROYA SUBDIVISION September 15, 2009 Pa e 6 6. Please submit support or easement information to allow the offsite drainage connection to Nightshade Road. Also provide calculations to support the size and capacity of the facility downstream to accommodate this project. The Aviara Subdivision CT 90-15 has calculations and hydrology study that limits the capacity of downstream drainage facilities. Please address the ultimate upstream drainage in this system. 7. The Tentative Map Drainage Study discusses the detention basin(s) and standpipe overflow. Please clarify the capacity of the existing storm system you are using downstream. Will the increase (or decrease) have an impact on either downstream system? Please check more than just the immediate pipe. Follow the design a little further to be assured that capacity or watertight joints are necessary. The overflow design seems to flow to the headwall adjacent to Nightshade Drive; will there be capacity for both drainage basins (Carnation Project and Muroya property) at this location? How about downstream to Alga Road? Same question applies to the headwall at Caspian Lane to Alga Road. 8. Please show street lights (if existing) at Black Rail Road and Avena Court. landscaping (PELA): The numbers listed below are referenced on the enclosed set of red line plans where appropriate for ease of locating each area of comment concern. Please revise accordingly. REPEAT COMMENTS 1-3 Completed. 4. All slopes which have been graded or disturbed, including "natural slopes", must meet the slope planting requirements. It does not appear that groundcover and shrub planting requirements have been met on "natural slopes". yrJ Review: See NEW COMMENTS 2A, 3A and 4A. Address all areas and address all required standards. 5-7 Completed. 8. Fire Zone A2, 82 and A3 must have permanent irrigation. The design must provide for head to head coverage. yri Review: Please revise note to clearly indicate complete irrigation of all planted areas. Fire suppression zones A 1, A2, A3, B 1, and 82 along with any planted areas require irrigation. 9-11 Completed. 12. RETURN RECLINES and provide 2 copies of only the concept plans on the next submittal. NEW COMMENTS 1A. Please address landscaping of all off-site graded areas. 2A. Please revise note to indicate that plantings are to meet slope revegetation requirement standards 1 - 4 except as modified by fire suppression requirements. ... GPA 06-09/ZC 06-08/LCC6-09/CT 06-27/CP 06-1~/CDP 06-30P 06-10/Hf'JiPP 07-02- MUROYA SUBDIVISION September 15, 2009 Pa e 7 3A. Please revise note to include plantings per slope revegetation requirements except as modified by fire suppression requirements. 4A. Trees and/or larger shrubs are required per standard number 4 of the slope revegetation requirements. Please insure all slope revegetation requirements are met except as modified by the fire suppression requirements. Check all notes on plans. 5A. Please insure landscaping is provided up to the back of the existing street landscape. Add landscaping as appropriate. 6A. Please provide appropriate container plants in the plantable wall cells. Seed alone is not sufficient. 7 A. Civil plans for the tentative map do not show a retaining wall in this location. Please coordinate plans or provide a copy of plans that show the wall for cross checking. 8A. Landscape elements over 30" in height (including planting measured at maturity) are not allowed at street corners within a triangular zone drawn from two points, 25' outward from the beginning of curves and end of curves. (See Appendix C.4). The same height limitation applies at driveways 25' from the edge of the apron outward along the curb then 45-degrees in toward the property. Please show and label the 25' sight line along with the 330' sight line and relocate wall/fence as required to be outside of these sight lines. 9A. Please show the 330' sight line on the entry enlargement on sheet 2a. Insure no conflicts. 10A. Please add these trees with sizes to the legend. 11A. Please add the palm symbol to the legend. 12A. There are several plants listed in the legend that are on the "Exotic Pest Plants of Greatest Ecological Concern in California" list (Schinus, Olea, Cistus). Please review all plants and modify as appropriate deleting invasive plant species. 13A. The recreation area amenities have been revised deleting the pool area. Additional amenities are needed such as a play area (active), and additional picnic tables and barbeques, etc. (passive). Please review.· 14A. Plans have been revised deleting a recreation area and substituting a "future retention basin lot". Please explain the future retention basin. It is recommended that this area be returned to a recreation area. 15A. Plans have been revised deleting a recreation area and substituting landscaped area. Landscaping shall be used to provide and enhance opportunities for outdoor recreation, relaxing, and eating. Although another recreation area is provided, recreational amenities are minimal. Please revise this area back to provide recreational activities. 16A. Please provide a revised colored recycled water use plan for review. The plan will be forwarded to Public Works Maintenance and Operations for review and any comments will be returned to the applicant. GPA 06-09/ZC 06-08/LC~6-09/CT 06-27/CP 06-19/CDP 06-32,_)P 06-10/HMPP 07-02- MUROYA SUBDIVISION September 15, 2009 Pa e 8 Fire: The Fire Department has no further issues with the project. August 5, 2009 Jason Goff City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 Ok Henthorn & AssociaO P.O. Box 237 Carlsbad, California 92018-0237 (760) 438-4090 Fax(760)438-0981 Subject: Muroya Subdivision-Re-submittal Package for CT 06-27/CP 06-19/CDP 06-32/ HDP 06-10/HMPP 07-02/GPA 06-09/ZC 06-08 Dear Mr. Goff: Enclosed is there-submittal package for the proposed Muroya Subdivision. The project has been revised to reflect the issues of concern identified in the City Planning Department letter dated June 23, 2007 and the comment supplement of July 18, 2007. Please refer to the transmittal letter for a listing of specific items contained in this re-submittal. In addition to items related to the response to City comments specifically addressing the letters of June 23, 2007 and July 18, 2007, you will find included documentation regarding discussions with San Diego Gas and Electric related to habitat and easement encroachments. The comment responses are numbered to be consistent with the numbering in the two comment letter for ease of review. Finally, an exhibit has been included to clarify overlaps between brush management zone 3 and the HMP required 20' habitat buffer. These items are identified in the transmittal form accompanying this letter. Pursuant to the Planning Department letter, now that all actions have been taken by the City Council and the California Coastal Commission relative to the revision of the Planned Development Ordinance, the application components should now be deemed complete. Each of the items contained in the letter and the engineering comment supplement of July 18, 2007, are addressed below: PLANNING ISSUES OF CONCERN ,, 1. Planned Development Ordinance-Section 21.45.060 (Table C): a) Section C.3 -Permitted Intrusions into Setback/Building Separation. Building plans for units 2 and 4 have been revised to remove media niches from building separation areas. The plan 2 fireplace protrusion into building separation area has been -1- 5927 Balfour Court, Ste. 112 • Carlsbad, CA 92008 c 0 reconfigured and does not exceed the maximum allowed 8 foot width. The plan 4 fireplace protrusion has been eliminated. b) Section C.4 -Streets. . Street tree locations in parkways have been modified to comply with spacing requirements. c) Section C.5-Drive-aisles. I. The plans provided in this re-submittal package have been reviewed with Monty Kalin, of the City Fire Prevention Division. The plans have been modified to provide variable width Fire Suppression Zones. In all instances the minimum configuration consists of a 20' wide A-1 zone and a 30' wide A-2 zone. Site design issues related to driveways and walls have been addressed on the plans. A width of 24' was maintained to accommodate public utilities and address access and turning issues identified in the engineering comment supplement dated July 18, 2007. II. Due to the fact that the design included excess visitor parking, spaces P-14 and P-15 have been redesigned and P-16 has been eliminated. d) Section C.8 -Screening of Parking Areas. An alternative parking design for visitor parking spaces P-14, P-15, and P-16 is being proposed per c) II , above. The landscape plans have been modified to conform to screening requirements of this section. e) Section C.10-Lighting. The proposed exterior unit lighting for the project is shown in the specification sheets provided by the applicant as noted in the transmittal form. Front lights will be photocell controlled 26 W fluorescent fixtures incorporating frosted glass diffusers. Rear patio lights will be manually controlled units. The locations of the lighting are shown on the front and rear elevations of the architectural plans. All street lights will conform to the City's standard overhead lighting requirements. 2. Planned Development Ordinance-Section 21.45.060 (Table E): a) Section E.3-Maximum Coverage. The acreage of the development lot (7.48 Ac.) is being used in the calculation of building coverage. The building area (60,900) that is used does not include porches without living area above, or loggias that meet the same definition. Second story overhangs in excess of 30" and balconies are included -2- c in building area. Recreation buildings have been removed from the plans and as such, the associated square footage has been eliminated. The proposed coverage is 18.7%. b) Section E.6 -Maximum Building Separation. Please see the response to No. 1(a) above. c) Section E.8-Private Recreational Space. The 400 square foot of private recreational space that is required for each unit (minimum 15 foot dimension) is now shown on the plans. 3. Architecture. a) City Council Policy 44 does apply to Table E projects. Revised applicable tables per the City Planned Development Ordinance are included with this re-submittal, please see transmittal form. b) Plan 1: The rear elevations of the Adobe Ranch and Andalusian styles were revised to provide additional architectural shutter features that are consistent with the architectural features included on the front elevations. The French doors were shown intended to be optional items. The floor plans have and elevations have been revised to reflect sliding doors. c) Plan 2: Including a Juliet balcony on the rear elevation off of the master bedroom was evaluated and found to undesirable for the Master Bedroom floor plan layout. In lieu of a Juliet balcony, shutters were added to rear elevation at the Master Bedroom. 4. Hillside Development/Constraints Map. Black Rail Road has been labeled on the vicinity map that is included on Sheet 1 of the tentative map. - 5. Geo-technical. A supplemental letter from the geo-technical consultants specifically addressing Section 21.203.040(3)(a) of the Coastal Resource Protection Overlay Zone, (addressing slope stability for a period of at least 75 years, or life of structure) is included, please see transmittal form. 6. Landscape. Details of proposed retaining walls have been included in the landscape plans. Decorative caps have been added to retaining walls that are facing the street or are visible from the interior of the project or public right-of-way. An irrigation detail for the plantable wall has been added to the landscape plans on sheet 2a. 7. Landscape. The type of vegetation that will be installed on the plantable wall has been clearly identified to eliminate concerns over adjacency impacts. A planting schedule for the proposed wall has been reviewed by the biologist to specifically address adjacency standards and the species of plants that are proposed. A letter from the project biologist is included in the re-submittal package, please see transmittal form. -3- 0 0 8. Fire Suppression/Brush Management Plan. The existing single-family dwelling does not need to be included as part of the Fire Suppression/Brush Management Plan since it is an existing occupied residence that will not be modified by the proposed project. This has been confirmed by Monty Kalin of the Carlsbad Fire Prevention Division. 9. The project site consists of 20.27 gross acres. The plans have been revised to correctly account for the right of way improvements to Black Rail Road. 10. Units 22 and 35 have been evaluated given the City's slope edge setback requirements. The future homeowner's ability to have a patio cover off the rear elevation given the slope edge building setbacks is feasible. The slope edge setback will accommodate patio covers and shade structures within depths of 13' and 12', respectively. No modifications are necessary. 11. The required mailing list must include the San Diego County Assessor's parcel number from the latest equalized assessment rolls. The rolls will be equalized before the mailing list could be used, thereby effectively rendering it invalid. The required list and labels will be provided subsequent to the equalization date later this month. 12. Project photo-simulation exhibits will be completed and submitted to the Planning Department upon receipt of confirmation that the project application is deemed complete. Engineering: The Engineering Department comment responses to the July 18, 2007, supplement are provided below: 1. The drainage basin information (General Design Note 19, Sheet 1) has been revised to include City of Carlsbad Master Drainage Plan I Basin "C". 2. Remedial estimated grading quantities and limits of over excavation as identified in the revised Geo-technical Report have been added to the plans. 3. The revised Geo-technical Report provided with this re-submittal package shows the full extent of over cut, offsite slopes, keys or buttresses anticipated to provide a stable pad and building foundation. 4. The plans and details have been revised to reference City Standard GS-14 and GS-15 and insure that units 21 thru 29, units 35 thru 37 and the Recreation Area are consistent with City Standards. Slope setbacks, brow ditches and lot or boundary condition have been shown on the plans. 5. The proposed Water Meter and Sewer Cleanout locations have been reviewed and revised. The typical detail (P1R, 3R, 4R) have been revised to correct the meter and -4- c 0 sewer cleanouts that are located within the proposed driveway. The notes: "Typical Water Meter Locations ... " and "Typical Sewer Locations subject to change ... " have been removed. 6. The RightofWay line has been added to the Typical Pedestrian Ramp Detail (Sheet 2). 7. The parking spaces (end and Drive "B") have been redesigned to a 24' length where the proposed angled curb prohibits drive in and out access. 8. The parking stalls on Drive "C" have been redesigned to accommodate the proposed overhangs ... The parallel parking on Drive "B" has been addressed in item 7, above. 9. The proposed 24 foot wide private drive and access plan (private drive "B" and "C) .has been retained. Truck turn details have been provided to demonstrate turning movements within this width. 10. Calculations to support the size and capacity of the offsite Nightshade facility downstream to accommodate this project are included in the revised drainage study included with this re-submittal package. Contact has been initiated with the A viara Master Association to obtain necessary easements to allow connection to facilities in Nightshade. Copies of the most recent contact letter and the July 16, 2009 A viara Master Association· Agenda ar~ provided to document that negotiations on-going between the private parties. Please see transmittal form. · 11. A revised drainage report is provided with this re-submittal package to demonstrate the ability of the down stream system to accommodate the proposed project. A basin has been added to address concerns expressed in this comment. 12. The· Tentative Map Drainage Study has been revised to address concerns with downstream capacities and the capability of the system to handle flows from the propos~d development. 13. Specific design specifications for proposed water treatment unit (s) are included in the revised drainage report provided with this re-submittal package. 14. A new street light is proposed along the project frontage at the intersection of Black Rail Road and Private Drive C. 15. The power pole adjacent to Lot 2 and adjacent to Unit No. 37 does not need to remain. The plan has been corrected to reflect that the existing pole is to be removed and the lines placed underground. Landscape: The numbers listed below are consistent with those referenced on the red line check prints as described in the Planning Department letter of June 23, 2007. -5- c 0 1. "Large Shrubs" have been broken out from "Accent Trees" in the legend. 2. One tree species has been assigned for each symbol used on the plan. 3. The species used in the hydro-seed mix on the natural slopes have been reviewed using the City of Carlsbad Restricted Lot or Parcel Fire Suppression Zone Planting Requirements as provided by Monty Kalin of the Carlsbad Fire Prevention Division. 4. All slopes whi~h have been graded or disturbed_have been addressed on the revised landscape plans. The slope between lots 32 and 33 as marked on the redline plan set does not need to meet these requirements as it is less than 3' in height. 5. Planting has been shown to the edge of the disturbance/ grading line. 6. Plans have been revised as.necessary to address item number 6 on the redlines. 7. Trees have been removed from the plan in Fire Protection Zone A-1. 8. Fire Zone· A2, B2 and B3 are proposed to have permanent irrigation that provides for head to head coverage. 9. Note A has been removed from the plans. 10. Trees and walls have been revised as shown on the re-submittal plan set. Historical Kentia Palms from the long existing Muroya nursery will be utilized at the entry. 11. Item No. 11 has been addressed on the re-submittal plan set and an entry wall now appears at the top of slope. 12. REDLINE CHECK PRINTS as provided are included in this re-submittal package, please see transmittal form. Fire: 1. Street A has been widened to 36' from curb to curb. 2. The plans have been revised to insure that no combustible wood fencing is provided within 100 feet of native undisturbed areas. A new symbol has been· added to the landscape plans on sheet 1 to clarify the use of non-combustible wood per the requirements. This is reinforced in detail H on sheet 4 of the plan set. 3. Brush management zones have been designed in conjunction with Monty Kalin of the City Fire Prevention Division to insure that Lots 21 thru 27 and 35 thru 37 comply with existing City of Carlsbad regulations relating to building restrictions. -6- 0 0 If you have any questions or need additional information, please contact me at your convenience, at (760) 438-4090, extension 225, or by e-mail, at henthom@jhenthom.com. cc: April Tornillo, Taylor Morrison Marybeth Murray, Hunsaker & Associates Rob Streza, GMP, Inc. Roy Capitan, Roberty Ridley Architects -7- c 0 Taylor Morrison June 26, 2009 To: Molly Dana, San Diego Gas and Electric From: April Tornillo, P.E. Subject: San Diego Gas and Electric Meeting Minutes June 26, 2009 Muroya Development CC: Jack Henthorn, Jack Henthorn and Associates Chuck Cater, Hunsaker and Associates Anita Hayworth, Dudek Tom Baine, Taylor Morrison of CA, LLC. Dear Molly, TAYLOR MORRISON bF CALIFORNIA, LLC Southern California Division 15Cushing Irvine, CA 92618-4220 p. (949) 341-1200 f. (949} 341-1 400 taylormorrison.com Thank you for meeting with us on Friday June 261h to discuss our development at the Muroya growers in Carlsbad. To be sure that the issues are correctly addressed, I would like to outline the meeting and items that were brought to our attention, including the new SDG&E policy as of recent. From our discussion, I understand that SDG&E has a firm stance against certain permanent improvements in the easement related to SDG&E future facilities and maintenance liability. The preliminary plans presented at our meeting on the development included proposed detention basins within the SDG&E easement. I understand that the detention basins proposed are not agreeable to SDG&E and Taylor Morrison will be making accommodations for them to remain outside of the SDG&E easement. I correct 1 It is my understanding from our meeting that SDG&E policy has changed and conceptual approval letters for developments in San Diego County are no longer written. Such a letter was prepared in the past for the Muroya development. I understand from our discussion, that as of recent, SDG&E has experienced difficulty with conceptual approvals and found plans on other projects inconsistent when it came to final engineering. However, we would like to be able to demonstrate to the City, that Taylor Morrison and SDG&E are communicating regarding the proposed preliminary plans. jcorrect I The development at the Muroya growers was given an original review by SDG&E in 2006 and /2007, and the review considered the inclusion of streets and sidewalks acceptable. From our meeting, I understand it to be allowable to have streets and sidewalks in the SDG&E easement, n fa o date. In this particular situation, since it was previously approved, SDG&E would work with the proposal as seen on the preliminary plans in 2006/2007. I indicated where those mitigations areas are located and that they are not within the easement area. jcorrect I Included in our discussion was the removal of undocumented fill and restoring the slope to a better condition within the SDG&E easement. This was illustrated on the preliminary plan updates to the tentative map. I gathered from our conversation that the removal of undocumented fill to repair the slope is considered acceptable by SDG&E. Taylor taylor . correct, see guidelines for Woodrow • • • • mornson u · · compaction. Communities~ ~~ Homes Inspired by You !a~ L...-___________ ___j 0 2 Muroya Development ~ Carlsbad The proposed storm drain inlets and pipes within the easement, as previously approved for the project, would be found acceptable in that they take storm water out of the easement area. Upon completion of final engineering and after Tentative Map approval, I understand that SDG&E will enerate consent a reements and Permission to Grade letters. Correct, only since the storm drain inlets and pipes within the easement as shown on the plans were previously approved. nex mee mg. ease sen us a copy o e m orma 1on regar mg weight requirements and truck weight requirements at the tower. Included with this, we appreciate any other information that you can provide for us to help facilitate us finalizing our tentative map updates. Please feel free to use the plans that were distributed in 'the meeting and a condensed copy is included in this letter. Please use the encroachment guidelines attached and sufficient H20 loading for the weight requirements. ~k~ pril T 11!0, P.E Desk:949~341-1289 Cell858 864 6206 april. tornill,o@us.taylotwoodrow. com GEOCON INCORPO R AT E D ProJect '\o. 0767 l-2-0 l Jul · I 0, 2009 Taylor Woodrow Homt:~ lncorporatt:d 15 Cushing !nine, Californ ia 9261R Attention: Ms. April Tornillo Subject: MUROYA PROPER Y CARLSBA D. CALIFO R\'lA GEOTECHN<AL CONSULT<NTS 0 RE PO SE TO REVIE\v COM\1E 'T' Rt:ferences: I. Pr •li" in<1ry Geotechnical lnl'estigation, J/umya Properw. Carlsbad, Calijom ia. prepared by Geoc.on Tncorpornte , dated JanuaJ)' 25, 2007 (Project No. 07671-52-0 l ). 2. Memomndum -Completeness and lssu RevieH, MuroJ a ResiJ ntial . ubdivision, Calrsbad. California prepared by The City of Carlsbad, dated June 23, 2007. Dear Ms. Torni llo: In accordance with your request, we have prepared this letter to address the re fe renced re\ iev. comment prepared by The City of Carlsbad. Specifically, this letter is intended to address Planning Js~u ' 5. The issue i~ li~ted below with the re~ponst: immediately following. ltem 5: Response: Geotcclln ic d. Pleas pr01•ide a supplemen;al letter from the g<'ntechnical ousultants specl}ically oddressing ection 21.20 .0-10(3)(a} of the oasral Rl'SOtii'C<! Protection Overlay Zon , which discusses slope stability .for a period oj at lea~ I 7 5 y~.:ars, or the /iff: of rite struullre. The referenced geotechnical inve·tigation presents a lope tabi lity , nalysi:> of the planned slopes with a calculated factor of afety of at lca:t 1.:, which is common standard of practice. We ex pect the planned ·lope can maintain :J factor of safety of at least 1.5 if th stte conditions remain the same for 75 )ears subs qu.:nt t our testing and observation serv ices durin0 the planned grading operations. We can not guar.:~nlct: that the slopes \\ill be stable for the requested time eriod. Water flO\\ ing over he top of lope. infiltrat ion of \\ater from hea\'y rain, broken utility line~. e.\ccssi\e land ·cape irrigation or fai led drainage de,·ices can reduce the calcu lated facto r of safety of the slope!.. Should you have que ·tions regarding this letter, or if\\ c may be of further service, pleJ. ·e contact the undersigned at your convenience. Vei) truly ) OUI~. GEOCO!\lt\CORPORATED If( , ~~~ Timotfiy P. \1alley Staff .eologist IPv!·S\'v :dmc 13) Addrt:,.,,ee t e-mail) Hunsal-er & A~soc1atcs ,\ttention: \1r. Chuck Cater J./ /Shawn Weedon Gl::'. 2714 6960 Flanders Drive • San Diego, California 92121-297 4 • Telephone (858) 558-6900 • Fax (858) 558-6159 DUDEK Ms. April Tornillo 0 CORPORATE OFF:CE 505 THiRD $TR.EH Taylor Morrison Services, Inc. 15 Cushing Irvine, CA 92618 Subject: Muroya Project Landscape Plan Review Dear April: 0 5332-01 As biologist for the Muroya Project, I have reviewed the Landscape Plans (dated July 14, 2009) as prepared by Gillespie Moody Patterson, Inc. The purpose of the review is to determine if non- native invasive plants are proposed to be located within the areas adjacent to the open space. I have reviewed the plant palettes for Hydrozone 3 planting, Hydroseed "A" and Hydroseed Mix 'B"and have compared them to the California Invasive Plant Council Invasive Plant Inventory (2007) as well as our in-house list of native plants for San Diego County which is based on the Jepson Manual. Based on that review, I can confirm that only indigenous, native species are proposed to be planted adjacent to the sensitive open space habitat area onsite. There are no plant species proposed to be planted adjacent to the open space that are considered invasive/noxious as determined by the Invasive Plant Inventory. If you have any questions regarding this letter, please contact me via telephone at (760) 479- 4239. Sincerely, Project Manager cc: Rob Streza, Gillespie Moody Patterson Inc. Jack Henthorn, Jack Henthorn & Associates WWW.DUDEK.COM , . o o FILE COPY 7/CJ'-I/o7 City of Carlsbad IQfUhhlh.M•X§.tllll•l§hl July 18, 2007 Bryan Bennett Jack Henthorn & Associates, Inc. 5365 Avenida Encinas, Suite A Carlsbad, CA, 92008 SUBJECT: GPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06- 10/HMPP 07-02-MUROYA SUBDIVISION The following is a list of items which are considered to be supplemental to the previous letter of incompleteness dated June 23, 2007. In that letter it was stated that the Engineering Department comments would follow under separate cover. Please find those comments attached below. If you should have any questions or wish to set up a meeting to discuss your application, please contact Jason Goff at (760) 602-4643. Sincerely, ~/L DONNEU Planning Director c: Gary Barberio, Team Leader Clyde Wickham, Project Engineer File Copy Data Entry 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us G) ''hp1'~~:19/ZC 06-08/LCPAQ-09/CT 06-27/CP 06-19/CDP 06-32~ 06-10/HMPP 07-02 (Muroya Subdivision) July 18, 2007 Pa e 2 Issues of Concern Engineering: , The following issues need to be resolved prior to resubmittal: 1. The drainage basin information (General Design Note 19, Sheet I) should include City of Carlsbad Master Drainage Plan I Basin "C". 2. Please add remedial estimated grading quantities and limits of over excavation as identified in the geotechnical report dated 4/26/2006. 3. The Preliminary Geotechnical Report (dated 4/26/2006) identified several areas of Debris Fill, Undocumented Fill, Colluvium, and generally undesirable geologic conditions requiring remedial grading to support the proposed development. Please show the full extent of over cut, offsite slopes, keys or buttresses anticipated to provide a stable pad and building foundation. 4. Units 21 thru 29 and the Recreation Area should be consistent with City Standard GS-14 & GS-15. Provide slope setbacks, brow ditches and lot or boundary condition. Please review Units 35 thru 37 for the same issue. 5. The proposed Water Meter and Sewer Cleanout locations must be reconsidered. Please locate meters and cleanouts out of driveways and travel ways .. The typical detail (P1R, 3R, 4R) should be revised to correct the meter and sewer cleanout that are located within the proposed driveway. The notes: "Typical Water Meter Locations ... " and "Typical Sewer (meter?) Locations subject to change ... " are not acceptable. Please correct the mistake and remove the note. We understand change is a possibility, but the plan should be as close to an approved design. 6. Please show Right of Way for Typical Pedestrian Ramp Detail (Sheet 2). 7. Please discuss parking detail with Planning Department. The 20 foot end space is permitted, provided there is drive in and out access. The proposed angled curb prohibits this maneuver. 8. The parking on Drive "C" overhangs 5' sidewalk by 2.5 feet. Relocate sidewalk or parking or provide a wider sidewalk to accommodate both. The parallel parking on Drive "B" is also an issue per item 7 above. 9. The proposed street and access plan (private drive "B" and "C) is extremely congested and difficult to maneuver. The minimum street width Street "B" and "C" should be 34' within a 56' General Utility and access Easement, similar to Street "A". Our Hillside Ordinance allows for a 32' wide street, single loaded which would work fine as a compromise. 10. Please submit support or easement information to allow the offsite connection to Nightshade road. Also provide calculations to support the size and capacity of the facility • 1 I ~ Q ~ GPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 (Muroya Subdivision) July 18, 2007 Pa e 3 downstream to accommodate this project. Submit copies of contact and negotiations with adjacent property owner to validate acquisition. 11. Please follow proposed drainage downstream to determine capacity or mitigation to accommodate the proposed project. Check-dams or downstream mitigation to address the additional runoff and velocity should be shown. Perhaps a basin (Structural BMP) and safe overflow structure could be provided on Lot 4. In reference, this is similar to the DeJong Project (CT 98-05) that your company designed and processed a few years ago with sensitive offsite drainage. 12. The Tentative Map Drainage Study Section 1.3 discusses the detention basin and overflow. Please clarify the capacity of the existing storm system that you are using downstream. Will the increase (or decrease) have an impact on either downstream system? Please check more than just the pipe connected to, follow the design a little further to be assured that capacity and watertight joints are necessary. The overflow design seems to flow to the Headwall. Will there be capacity for both drainage basins at this location? 13. Provide specific product or design specs for proposed water treatment unit(s). "Per Manufacturer" is insufficient to support the proposed system or BMP. 14. There are no street lights proposed along the project frontage (Black Rail Road), please take a look at this and revise if necessary. 15. Provide information to back up and explain why the power pole adjacent to Lot 2 and adjacent to Unit No. 37 needs to remain. We would hope this project would underground all power lines and poles along the complete project frontage. Page 1 of 1 Jason Goff-Muroya Subdivision From: Jason Goff To: henthorn@jhenthorn.com; Date: 07/06/2007 11:15 AM Subject: Muroya Subdivision Attachments: muroya2[1].pdf Jack, Please disregard the previous completeness letter dated June 23, 2007. The Muroya Subdivision as proposed in the second review is still deemed incomplete. Attached is a copy of the revised incompleteness letter also dated June 23, 2007. Sorry for any confusion. Jason Goff Associate Planner City of Carlsbad Planning Department 1635 Faraday Avenue Carlsbad, CA 92008 760-602-4643 jgoff@ci.carlsbad.ca.us file://C:\Documents and Settings\J goff\Local Settings\Temp\XPGrp Wise\468E2440GW-... 07/06/2007 ·,, City of Carlsbad I iJ 61 ,J II I ;t. I •A§ ·fill I; .t§ Ill June 23, 2007 Bryan Bennett Jack Henthorn & Associates 5365 A venida Encinas, Suite A Carlsbad, CA 92008 SUBJECT: GPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06- 10/HMPP 07-02-MUROYA SUBDIVISION Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning Department has reviewed your development applications, application nos. GPA 06-09, ZC 06-08, LCPA 06- 09, CT 06-27, CP 06-19, CDP 06-32, HDP 06-10, and HMPP 07-02, as to their completeness for processing. The items requested from you earlier to make your General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit, application nos. GPA 06-09, ZC 06-08, LCPA 06-09, CT 06-27, CP 06-19, CDP 06-32, HDP 06- 10, and HMPP 07-02 complete have been received and reviewed by the Planning Department. The General Plan Amendment (GPA), Zone Change (ZC) and Local Coastal Program Amendment (LCPA) applications are complete, as submitted. The remaining development applications consisting of a Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit are deemed to be incomplete. Since the legislative actions (GPA, ZC and LCPA) are being processed concurrently with the quasi-judicial actions, the other development permit applications must remain incomplete until the legislative actions are approved by the City Council. Furthermore, as acknowledged by Taylor Woodrow Homes in their letter dated May 21, 2007, the application will remain incomplete until such time as the California Coastal Commission has adopted the City of Carlsbad's amended Planned Development Ordinance. Staff will continue to concurrently process and take the development applications to the decision-making bodies together and in an order by which the applications can be decided upon. Although the initial processing of your application may have already begun, the technical acceptance date is acknowledged by the date of this communication. The City may, in the course of processing the application, request that you clarify, amplify, correct, or otherwise, supplement the basic information required for the application. In addition, you should also be aware that various design issues may exist. These issues must be addressed before this application can be scheduled for a hearing. The Planning Department will begin processing your applications as of the date of this communication. At this time, the City asks that you provide five (5) complete sets of the revised development plans so that the project can continue to be reviewed. 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us (!} GPA 06-09/ZC 06-08/LC~ 06-09/CT 06-27/CP 06-19/CDP 06-~P 06-10/HMPP 07-02- MUROYA SUBDIVISION June 23, 2007 Pa e2 Please contact your staff planner, Jason Goff, at (760) 602-4643, if you have any questions or wish to set up a meeting to discuss the application. Sincerely, ~ ftW,O¥- DONNEU Planning Director DN:JAGO:lt c: Gary Barberio, Team Leader Clyde Wickham, Project Engineer File Copy Data Entry GPA 06-09/ZC 06-08/L& 06-09/CT 06-27/CP 06-19/CDP 06-~P 06-10/HMPP 07-02- MUROYA SUBDIVISION June 23, 2007 Pa e3 ISSUES OF CONCERN Planning: 1. Planned Development Ordinance-Section 21.45.060 (Table C): a) Section C.3 -Permitted Intrusions into Setback/Building Separation. Media niches are not considered a permitted intrusion into the required yard or building separation area, and fireplaces also cannot exceed an 8 foot width when protruding into the building separation area. This project has a minimum requirement of 10 feet of building separation. It appears that the Plan 2 and 4 violates this requirement in several areas. Please revise all plans to be consistent. b) Section C.4 -Streets. Street trees are required to be spaced no further apart than 30 feet on center when located within a parkway. There are several areas along Street "A" where additional trees are necessary to fulfill the minimum spacing requirements. Please revise. c) Section C.5-Drive-aisles. I. The Fire Department is requiring that all dwelling units be outfitted with automatic fire sprinklers (see Fire Department comments below). As such, we would suggest reducing the private drives down to the minimum 20 foot width in order to reduce retaining walls and provide additional landscape and yard areas to each of the units and the project as a whole. II. Visitor Parking Spaces P-14, P-15 and P-16 need to be redesigned to provide the minimum 24 foot vehicle back-up/maneuvering area. d) Section C.8 -Screening of Parking Areas. Please explore an alternative parking design for visitor parking spaces P-14, P-15, and P-16, to better conform to screening requirements of this section. e) Section C.1 0 -Lighting. Please include details of the proposed exterior lighting for the project. Given the scale of the development and the surrounding sensitive habitat, smaller scale decorative type lighting should be considered. 2. Planned Development Ordinance-Section 21.45.060 (Table E): a) Section E.3-Maximum Coverage. Please show how you are calculating the maximum lot coverage for the project. What is being used as the net developable area? The net developable area for the purposes of lot coverage is not the same as the net developable acreage for determining density of the entire 20.27 acre site. Also, it doesn't appear that the building coverage calculations shown on Sheet 2 of the Civil Plans is accounting for loggias, covered porches, second story overhangs, or the pool GPA 06-09/ZC 06-08/LC~ 06-09/CT 06-27/CP 06-19/CDP 06-~P 06-10/HMPP 07-02- MUROYA SUBDIVISION June 23, 2007 Pa e4 area recreation facilities. Please revise the plans and the Table "E" Compliance Table to show exactly how you are calculating total lot coverage. b) Section E.6-Maximum Building Separation. Please see No. 1(a) above and revise plans to comply. c) Section E.8-Private Recreational Space. Please plot the 400 square foot of private recreational space that is required for each unit (minimum 15 foot dimension). Private recreational space shall be designed to be functional, usable, and easily accessible from the dwelling unit it is intended to serve. 3. Architecture. Please revise as follows: a) Please note that City Council Policy 44 does not apply to a Table E projects. b) Plan 1: Please revise the rear elevations of both the Adobe Ranch and Andalusian to provide additional architectural features that are more complimentary with the architectural features included on the front elevations. Also, please revise the front elevations to show French doors off of Bedroom No. 3 in order to match the proposed floor plans. c) Plan 2: Please consider including a Juliet balcony on the rear elevation off of the master bedroom in accordance with each architectural style. 4. Hillside Development/Constraints Map. Please label Black Rail Road on the vicinity map that is included on Sheet 1. 5. Geotechnical. Please provide a supplemental letter from the geotechnical consultants specifically addressing Section 21.203.040(3)(a) of the Coastal Resource Protection Overlay Zone, which discusses slope stability for a period of at least 75 years, or life of structure. 6. Landscape. Include a detail of proposed retaining walls. Any retaining walls that are facing the street or are visible from the interior of the project or public right-of-way should include a decorative type cap. The plantable wall must also include an irrigation detail. 7. Landscape. With the plantable wall being located adjacent to the natural habitat, staff is concerned about adjacency impacts from the type of vegetation that will be installed on the wall. Nothing is included on the landscape plans to identify what type of vegetation will be planted on the wall. Please include a planting schedule for the proposed wall, and have the biologist provide a supplemental letter that specifically addresses adjacency standards as it relates to the plantable wall and the species of plants that are proposed. .. GPA 06-09/ZC 06-08/LC~ 06-09/CT 06-27/CP 06-19/CDP 06-~P 06-10/HMPP 07-02- MUROYA SUBDIVISION June 23, 2007 Pa e 5 8. Fire Suppression/Brush Management Plan. The existing single-family dwelling needs to be included as part of the Fire Suppression/Brush Management Plan. Please revise the plans and the Biology Report to reflect this revision and any type of biological impacts. 9. The project site consists of 22.27 gross acres, where as the combined acreage of proposed Lots 1-5 equates to 19.4 acres. Where's the difference? Please note the difference on plans if it is coming out of the right of way improvements to Black Rail Road. 10. The plotting of Units 22 and 35 will seriously impact the future homeowner's ability to have a patio cover off the rear elevation given the slope edge building setbacks. In order to provide future homeowner's with the ability to have a patio cover, or other shade type structure, we would strongly suggest that you redesign these two units such that future opportunities could be available. One option would be to eliminate the center courtyard altogether and make up the difference in the rear yard. 11. A State-mandated 6 week public review period is required for the Local Coastal Program Amendment (LCPA). The notice has been prepared for LCPA 06-09. However, mailing labels are necessary in order to send the notice out. Please submit the following information as soon as possible for the notice and please sign the enclosed form: a) 600' Owners List-a typewritten list of names and addresses of all property owners within a 600 foot radius of the subject property, including the applicant and/or owner. The list shall include the San Diego County Assessor's parcel number from the latest equalized assessment rolls. b) 100' Occupant List-(Coastal Development Permits Only) a typewritten list of names and addresses of all occupants within a 100 foot radius of the subject property, including the applicant and/or owner. c) Mailing Labels-two (2) separate sets of mailing labels of the property owners within a 600 foot radius of the subject property. For any address other than a single-family residence, an apartment or suite number must be included. DO NOT provide addressed envelopes -PROVIDE LABELS ONLY. Acceptable fonts are: Arial11 pt, Arial Rounded MT Bold 9 pt, Courier 14 pt, Courier New 11 pt, and MS Line Draw 11 pt. Sample labels are as follows: ACCEPTABLE Mrs. Jane Smith 123 Magnolia Ave., Apt #3 Carlsbad, CA 92008 ACCEPT ABLE (with APN) 209-060-34-00 MRS JANE SMITH APT3 123 MAGNOLIA AVE CARLSBAD CA 92008 d) Radius Map-a map to scale, not less than 1" = 200', showing all lots entirely and partially within 600 feet of the exterior boundaries of the subject property. Each '• .,...... ~. GPA 06-09/ZC 06-08/L~ 06-09/CT 06-27/CP 06-19/CDP 06-~P 06-10/HMPP 07-02- MUROYA SUBDIVISION June 23, 2007 Pa e6 of these lots should be consecutively numbered and correspond with the property owner's list. The scale of the map may be reduced to a scale acceptable to the Planning Director if the required scale is impractical. e) Fee - a fee shall be paid for covering the cost of mailing notices. Such fee shall equal the current postage rate times the total number of labels. Cash check (payable to the City of Carlsbad) and credit cards are accepted. 12. Project photo-simulation exhibits must be completed and submitted to the Planning Department upon a determination that the project application is complete. The photo simulation exhibits should be scaled representations of the project, as viewed from adjacent streets and adjacent developed single-family residential properties. Engineering: The Engineering Department comments will follow under separate cover. Landscape: The numbers listed below are referenced on the red line check prints where appropriate for ease of locating the area of the comment concern. 1. Break out "Large Shrubs" from "Accent Trees" in the legend. 2. Select one tree species for each symbol used on the plan. The legend is too broad to know whether appropriate tree species have been selected. The trees range from very large to small trees. 3. The species used in the hydroseed mix on the natural slopes contain many species which are considered to be high fuel, including Artemisia, Baccharis, Dodonaea, Eriogonum, Muhlenbergia and Salvia. Since these slopes are within the Fire Protection Zones the species are not appropriate in this area. 4. All slopes which have been graded or disturbed, including "natural slopes", must meet the slope planting requirements. It does not appear that groundcover and shrub planting requirements have been met on "natural slopes". 5. Show planting to the edge of the disturbance line. 6. Please refer to Item No.6 on the redlined check prints and explain what is happening this area of disturbance. Please revise plans as necessary. 7. Fire Protection Zone A-1 should not have trees. The legend indicates this, but the plan shows trees in this zone. . . . . -.......... , GPA 06-09/ZC 06-08/L~ 06-09/CT 06-27/CP 06-19/CDP 06-~P 06-10/HMPP 07-02- MUROYA SUBDIVISION June 23, 2007 Pa e7 8. Fire· Zone A2, B2 and B3 must have permanent irrigation. The design must provide for head to head coverage. 9. Note A is not appropriate. All areas of disturbance to existing soil must be restored to their original condition. 10. These trees should be located on the street side of any back yard fence. 36" box trees are problematic on slopes. Adjust walls to provide an appropriate location for specimen entry trees. 11. Please refer to Item No. 11 on the redlined check prints and identify whether or not a fence exists in this location? Please revise plans to clarify. 12. Please RETURN all REDLINE CHECK PRINTS with the next submittal. Fire: 1. All dwelling units shall be provided with Automatic Fire Sprinklers. This item is a requirement because of the narrow street section ( <36'), and Fire Department vehicular access from the street places each proposed residence outside of our primary hose reach of 150 feet. This measurement is taken from the centerline of the street and as a man and hose would travel in a provided path of travel to the center of the furthest reaching wall of the dwelling. If you refer to the City Engineering Standard for cul-de-sac streets you will find that cul-de-sac streets are to be 36 feet curb-to-curb with 24 dwelling units or less. This street is 34' curb-to-curb and is serving 34 units. If you were to use the livable streets concept plan you would find that 20 dwelling units are permitted on 36-foot streets and all dwelling units are sprinkled with fire resistive construction on all dwelling units. 2. Pursuant to Section IV .F Fire Protection Program Policies and Requirements of the City of Carlsbad Landscape Manual Item F.3-6, absolutely no combustible wood fencing shall be allowed within 100 feet of native undisturbed areas. Please revise plans to be consistent. 3. This shall also require that Lots 21 thru 27, 29 and 35 thru 37 be restricted as not to permit the construction or installation of combustible structures within 100 feet of undisturbed natural vegetation, examples of which would be pool houses, cabanas, gym sets and patio decks and covers/canopies. IJrm Taylor Woodrow May 21,2007 City of Carlsbad Planning Department 1635 Faraday Ave. Carlsbad, CA 92008 Attention: Don Neu 0 Taylor Woodrow Homes, Inc Southern California 15 Cushing Irvine, CA 92618 Tel 949-341-1200 Fax 949-341-1400 Subject: GPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02-Muroya Tentative Map and Condominium Plan Permit Consent Letter Dear Mr. Neu, In response to our meetings with the City of Carlsbad's planning department, Taylor Woodrow Homes is pleased to submit a detached condominium development consistent with the standards of the amended Planned Development ordinance, approved by City Council in February 2007. The California Coastal Commission has not to date adopted the City of Carlsbad's amended PO ordinance, and it was expressed by planning staff that the proposed tentative tract map would be processed alongside the approval of the amended PO ordinance. Taylor Woodrow understands that the enclosed tentative map will be processed at-risk and is subject to PO ordinance changes. Also, we understand the possibility of a prolonged adoption process. Taylor Woodrow looks forward to the adoption of the PO ordinance and establishing the ground work for infill projects in the City of Carlsbad. Sincerely, Gil Miltenberger Sr. VP/Regional Manager I I May 21,2007 Jason Goff City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 Ock Henthorn & AssociaO 5365 Avenida Encinas, Suite A Carlsbad, California 92008 (760) 438-4090 Fax (760) 438-0981 Subject: Muroya Subdivision-Resubmittal Package for CT 06,27/CP 06,19/CDP 06,32/ HDP 06,10/HMPP 07,02/GPA 06,09/ZC 06,08 Dear Mr. Goff: Enclosed is there-submittal package for the Muroya Subdivision residential project. The project has been revised to reflect the incomplete items and issues of concern identified in the City's letters dated January 12, 2007. Each of the items contained in the letter are addressed below: PLANNING: INCOMPLETE ITEM 1. Enclosed with the project resubmittal are the compatibility matrices that demonstrate project compliance with Tables C (General Development Standards) & E (Condominium Projects) of the newly adopted Planned Development Ordinance. Please see Planning: Issues of Concern No. 1 below for further discussion. 2. The vicinity map on all of the plan sets have been updated to label Black Rail Road as requested. 3. HMPP 07-02 has been added to the upper right hand corner of the enclosed plan sets. 4. Enclosed with the resubmittal package is a full sized colored recycled water use plan, as requested. 5. Photographs of the subject property have been enclosed as requested. 6. Enclosed with the project resubmittal is the signed certification form for the posting of the site along with photos of the early public noticing sign. 7. Policy No 37: a. The site has been posted pursuant to the Early Public Noticing requirement. The certification form along with photographs of the sign are enclosed. b. Once the application is deemed complete a photo-simulation of the proposed project will be prepared. -1- '' '' c 0 8. An additional copy of the exhibit illustrating the requested General Plan Amendment, Zone Change and modifications to the Local Coastal Program designations with the acreages involved is enclosed with the resubmittal package. 9. The enclosed Hillside Development Permit/Constraints Map has been stamped and signed by Hunsaker & Associates, the civil engineer of work for the project. 10. Two slope edge setback sections have been provided on Sheets 5 and 6 of the enclosed tentative map for those lots applicable to the setback. Please refer to the enclosed tentative map for details. 11. The recommended surveys of the Biological Resources Report have been completed and will be forwarded under a separate cover. 12. The Biological Resources Report has been updated to include the Type "F" mitigation fee for disturbed habitat. The updated report will be forwarded under a separate cover with the surveys for the special status plant species. 13. The Biological Resources Report has been updated to include a discussion for the project's compliance with the management and conservation goals for HMP species. Please refer to the updated report for details. 14. The Biological Resources Report has been updated to include additional sections that specifically address each of the five adjacency standards that are outlined in the HMP. Please refer to the updated report for a detailed discussion. 15. The references within the biological report for the grading restrictions during the rainy season have been removed as requested. 16. Enclosed with the project resubmittal please find the Phase I and Phase II reports for the subject property, including an updated Soils report that addresses the testing and analysis of soils. An analysis of the agricultural affects on the site was also conducted and is found within the Phase II report. PLANNING: ISSUES OF CONCERN 1. A number of the items listed in the City's comment letter addressed the inconsistencies of the project with the current Planned Development Ordinance, Section 21.45 of the Carlsbad Municipal Code. On March 13'h of this year the project applicant along with representatives from this office met with Gary Barberio and yourself at the City of Carlsbad to review these comments and for the continued review of the. subject project under the modified Planned Development ordinance recently adopted by the City Council. The applicant is aware and understands that the new ordinance will not take effect until the California Coastal Commission approves the amendment to the Local Coastal Program. They are also aware that the continued review of the project under the new regulations will be solely at their risk and the project application cannot be deemed complete until that approval from the -2- '' c 0 Coastal Commission is granted. Enclosed with the resubmittal package is a letter from Taylor Woodrow Homes that states the above. a. Minimum lot sizes are not applicable with the new Planned Development Ordinance for condominium projects. b. The project complies with the maximum allowed building coverage of 60% for condominium projects per the new Planned Development Ordinance. The proposed project's building coverage has been calculated at 12% and is noted on the cover sheet of the enclosed tentative map. c. Minimum lot widths are not applicable with the new Planned Development Ordinance for condominium projects. d. The project has been revised to reduce the number and size of the proposed retaining walls to the greatest extent possible. Please refer to the enclosed tentative map for the exact locations and heights of the proposed retaining walls. e. All applicable setbacks were evaluated under the new Planned Development Ordinance for condominium projects. As proposed the subject project meets or exceeds all of the applicable setbacks for the subject project. f. Side yard setbacks pursuant to TableD are not applicable with the new Planned Development Ordinance for condominium projects. g. Rear yard setbacks pursuant to Table D are not applicable with the new Planned Development Ordinance for condominium projects. h. The 18'x18' private rear yard area is not applicable with the new Planned Development Ordinance for condominium projects. Sheet 3 of the enclosed tentative map includes an exhibit that illustrates compliance with the requirements for private recreational space per the new ordinance. i. The Garage Standards are not applicable with the new Planned Development Ordinance for condominium projects. j. Additional areas of enhanced pavement have been provided as required by the Planned Development Ordinance for private driveways and motorcourts. Please refer to the enclosed plan sets for details. k. Private Drive "B" has been reduced in width to 24 feet as suggested to reduce the height and number of the proposed retaining walls. 1. Additional landscaping has been provided around the visitor parking spaces located at the southern portion of the project adjacent to Black Rail Road. The proposed landscaping adequately screens the parking spaces from the public view as required by code. A detailed section has been provided on the -3- conceptual landscape plans to illustrate the proposed landscape screening for this area. m. The enclosed site plan for the subject project includes designations for the elevation styles. Please refer to the enclosed site plan within the tentative map plan set for details. n. See item "m" above. No identical plan types with the same elevation style occur adjacent to one another. Please refer to the enclosed site plan within the tentative map plan set for details. o. The proposed single-story units have been revised to reduce and break up the footprint of the unit as much as possible. Unfortunately in order to create a single-story unit that compares in size with the square footages of the other plan types the footprint of the unit must be larger than those of the two-story plan types. The alternative to utilize a reduced second story unit pursuant to Guideline No. 6 of Policy 44 does not entirely eliminate the requirement for a single-story unit it only reduces the number required. The net result is an increase to the number of plan types with a larger building footprint. Therefore due to the constrained nature of the site the original proposal of six single-story units with a slightly modified footprint is still being proposed as a part of the subject application. p. The calculations for the single story edge illustrating compliance with Guideline No.9 are shown on the enclosed architectural plan sets. q. The Policy 44 Compliance Table has been revised to correctly state Guideline No. 10. Enclosed please find the updated compliance table. r. Pursuant to the meeting with City staff, it was discussed that the average side yard setback requirement does not directly correlate with the proposed condominium product type. Though the project does meet the average side yard setback as stated in the City's comment, the intent to provide cutouts and offsets was lacking for the Plan 1. It will be at the City's discretion whether or not a deviation of the standards is the appropriate vehicle for showing compliance with this guideline. s. As discussed during the meeting with City staff, with the addition of walkways from the front entries to the proposed sidewalks along Private Street "A" and the relocation of the front entries for the plan types 4 along the northerly boundary, the intent of Guideline No. 16 is met. t. As discussed during the meeting with City staff the project does include a combination front, side loaded and recessed garage configurations that meet the intent of Principal No. 2 of City Council Policy No. 66. -4- c 2. As stated above, the project has been revised to reduce the number and size of the proposed retaining walls to the greatest extinct possible. Please refer to the enclosed tentative map for the exact locations and heights of the proposed retaining walls. The pad height proposed for the area encompassing Units 35,37 is constrained by the driveway elevations for Private Drive "C" and the elevations of the existing sewer main within Black Rail Road. As a result of these constraints the pad height for this area is proposed at the lowest elevation to meet the City engineering standards. 3. The project is proposing the development of natural slopes with a gradient of 40% or greater as shown on the enclosed slope analysis on Sheet 4 of the Hillside Development Permit/Constraints Map plan set. However, those areas proposed for development do not meet the criteria of undevelopable as defined by Section 21.95.120(B)(1), specifically these areas individually are not greater than ten thousand (10,000) square feet and do not comprise a prominent land form feature. The existing slopes that meet the criteria have been preserved as shown on the slope analysis exhibit. Please refer to Sheet 4 of the Constraints Map for further details. 4. The note for the impacts to dual criteria slopes has been updated to separate the impacts due to grading and those due to fire suppression. 5. Section 21.95.120(F)(1) of the Carlsbad Municipal Code is not applicable to the proposed 2:1 slope located in the northwestern comer of the property. The proposed slope is not greater than twenty feet in height and not more than two hundred feet in length. Therefore contour grading for the proposed slopes is not required per the cited section of the municipal code. 6. An additional slope profile has been included on Sheet 2 of the Hillside Development Permit/Constraints Map that crosses Units 6, 10, 14 and 18 from Black Rail Road to Nightshade Road as requested. 7. The use of double retaining walls within the project has been eliminated as requested. As mentioned above, the overall heights of the proposed retaining walls were reduced to the maximum extent feasible. However, the proposed retaining wall behind Units 35-37 was not able to be reduced due to the constraints of the existing utilities and the nature of the steep slopes within the preserved open space adjacent to the proposed development. The applicant is therefore proposing a plantable retaining wall that will exceed the maximum six (6) feet permitted by the municipal code for a limited distance but will be planted to blend in with the surrounding slope landscaping. The maximum height of the proposed wall is nine and a half (9.5) feet at its peak in the middle of the wall and reduces quickly as it stretches out along the proposed toe of the slope. Please refer to the enclosed tentative map for details. 8. The retaining walls previously proposed along Private Street "A" have been reduced in height or eliminated within the front yard setback. Please refer to the enclosed tentative map for details. -5- c 9. The 'Property Line -Side Yard Plantable Area Detail' on Sheet 2 of the tentative map has been revised to show a minimum of three (3) feet between the retaining walls as requested. 10. Additional elevations for the retaining walls near Unit 15 have been included as requested. The retaining wall previously proposed adjacent to Unit 9 was eliminated with the current resubmittal. 11. Comment noted. The number of inclusionary housing credits proposed for purchase for the project will be seven (7). 12. The fire suppression zones have been shown on the enclosed plan sets as requested. The only rear yard affected by the fire suppression zones is behind Unit 23. It is only a small portion of the rear yard for Unit 23 that will include a portion of the Zone 1 Fire Suppression Zone. This area will be disclosed to the future homebuyer as well as documented within the project CC&R's for enforcement. 13. The enclosed conceptual landscape plans and tentative map have been revised to illustrate the proposed project entry at the intersection of Private Street "A" and Black Rail Road. A detail and associated section of the proposed entry are shown on Sheet 2a of the enclosed conceptual landscape plan set. 14. An additional copy of the exhibit illustrating the requested General Plan Amendment, Zone Change and modifications to the Local Coastal Program designations with the acreages involved is enclosed with the resubmittal package. 15. Under the provisions of the new Planned Development Ordinance the requirement for RV storage is no longer applicable to projects less than one hundred (100) dwelling units. Therefore the previously proposed RV storage area has been removed from the enclosed plan sets. 16. Please see No. 15 above. ENGINEERING: ISSUES OF CONCERN 1. The project application numbers have been included within the upper right hand comer of the enclosed plan sets as requested. 2. Note No. 19 has been added to the cover sheet of the enclosed tentative map under the 'General Design Notes' that includes the requested CFS and drainage basin information. The project ADT is located within Note No. 11 under 'General Notes' and the water and sewer generation information is located within Notes No. 15 & 18 under 'General Design Notes'. Please refer to Sheet 1 of the enclosed tentative map for details. 3. Enclosed with the resubmittal package is an 'Earthwork Balance Sheet' prepared by Hunsaker & Associates for the subject project. Included within the work sheet are -6- c the corrective grading estimates based on the information ascertained from the soils report for the project. 4. The areas of debris fill, undocumented fill and colluvium are still being evaluated by Geocon, Inc and Hunsaker & Associates as to extent of the effect on the proposed grading. When the soils and civil engineers have completed their evaluations of the existing conditions and prepare alternative solutions to rectify the conditions, it will be necessary to meet with the project engineer and planner to determine the best solution for the project. 5. Hunsaker & Associates did evaluate the proposed condition along the northern property for consistency with City Standard QS,14 and QS,15. 6. Pursuant to the new regulations contained with the Planned Development Ordinance, recently adopted by the City Council, exclusive use areas are no longer required for condominium projects. Therefore conflicts with access, utilities, etc and the exclusive use boundaries is no longer an issue. Typical details have been provided on Sheet 2 of the enclosed tentative map that illustrates the anticipated locations of future water and sewer laterals. These typical locations are preliminary and are subject to be modified during the final engineering process. 7. Per the request of the Planning Department, the widths of Private Drives "B" and "C" were reduced to twenty,four (24) feet in order to reduce the height and number of the proposed retaining walls. The widths proposed are consistent with the minimum dimensions for private drives with the Planned Development ordinance. All proposed parking along either of the private drives is located within parking bays outside of the minimum drive aisle width. Please refer to the enclosed tentative map for details. 8. Pursuant to Section 21.44.050 of the Carlsbad Municipal Code the minimum drive aisle for ninety,degree parking is twenty,four (24) feet. The proposed drive aisle for Private Drive "C" is twenty,four (24) feet providing adequate ingress and egress for the proposed parking spaces. 9. T ypicallocations for the water and sewer service of each proposed unit have been illustrated on Sheet 2 of the enclosed tentative map. These typical locations are preliminary and are subject to be modified during the final engineering process. A joint utility trench for the dry utilities has also been included the proposed private street/drive sections on Sheet 2 of the tentative map. 10. The applicant is currently in discussions with the adjacent property owner for the permission to connect the water, sewer and storm drain to the existing facilities within Nightshade Road. Once the project design has been found to be acceptable by both the Planning and Engineering Departments formal documentation will be prepared and submitted to the City. A condition of approval for offsite improvements is also acceptable to the applicant. The calculations for the size and capacity of the existing downstream facility are included within the enclosed drainage study for the project. -7- c 11. A full downstream analysis of the existing storm drain infrastructure located within the adjacent Nightshade Road is provided within the Appendix of the "TM Drainage Study for Muroya" by Hunsaker & Associates, dated May 2007. This analysis illustrates the existing systems ability to safely convey peak flows generated via the residential tributary areas. It should also be noted that developed peak flows generated via the Muroya development tributary to the aforementioned existing storm drain system are mitigated via a proposed detention basin within the Muroya development. Developed flows are reduced to flows experienced in current pre-developed conditions, hence the Muroya development has no hydraulic impact on the existing storm drain. A basin is not required at lot 4 as peak flows draining from this portion of the developed have been reduced by approximately 4. 7 cfs from those experienced in current pre-developed conditions. As flows have been reduced, check damns will not be implemented within the site (as the portion of the site the plan checker is referring to will not be developed and is located within environmental sensitive portions of the site). 12. The requested SWPP notes and structural BMP information has been included on Sheet 3 of the enclosed tentative map. Please refer to the enclosed tentative map for details. 13. A note has been added to the parking detail located on Sheet 2 of the enclosed tentative map that identifies the typical structural section per the Carlsbad Engineering Standards. 14. The location of the existing street lights has been evaluated and documented by Hunsaker & Associates. Enclosed please find the photo documentation for the existing improvements along Black Rail Road. LANDSCAPE: ISSUES OF CONCERN The following responses are from Chris Gustard of GMP, Inc., the landscape architect of record: 1. We are confident that the level of detail on our resubmitted concept plans will facilitate you to make a full and complete review on the 2nd submittal and offer our team additional staff comments where necessary and within the requirements set forth in the Carlsbad Landscape Manual. 2. Our plant legend was revised to meet this request. Our hatching is consistent throughout the plan sheets and ties back to the plant legend located on sheet 1 a. 3. The hydroseed mixes were modified and detailed out within the plant legend and concept plan. The coastal sage scrub mix location was changed to be solely on the perimeter slopes. Our streetscape design theme is more of a refined and transitional plant palette utilizing many drought tolerant grasses and shrubs along with the use of -8- '. some succulents and rushes. Groundcover species, not hydroseed, will primarily be used in the streetscape and common areas throughout the site. 4. The plant legend was completely revised. See response #3. 5. All easements and ROW lines, property lines and lot lines are shown where appropriate on the concept plan and also on new enlargements. 6. There are no planned bio-swales at this time, however we did add in a number of locations of decorative cobble in the passive park area and overlook park. These areas will be able to take some level of nuisance water drainage. 7. Per the phone discussion between Chris Gustard and the City's landscape consultant, it determined to be acceptable if we noted on the plans that the quantity of shrubs did not have to be shown, however 50% of the shrubs are to be a minimum size of 5 gallons and with the remaining 50% to be a minimum size of 1 gallon. We have noted this in many areas of the revised plans including the plant legend Sheet 1 and Sheet 1 a of the enclosed conceptual landscape plan. 8. A separate recycled water use plan was prepared and included with the resubmittal package for the Water Departments' review. 9. The maintenance responsibility plan has been revised and clearly delineates areas of responsibility. The plan is labeled with locations of concrete maintenance strips or maintenance separators such as walls, sidewalks etc. Generally, the front yards will be installed by the builder and then will be maintained by the individual homeowners. 10. On the revised plans we are showing full landscaping in all front yards through the typical front yard landscape concept plan. Please see Sheet 8 of the enclosed conceptual landscape plans for details. The developer is to install all landscape and irrigation per the typical front yard concept plan for each unit throughout the subdivision. The main concept plan shows only street trees, front yard trees and accent trees for clarity reasons and do coordinate back to the project plant legend on Sheet 1a. 11. We have noted on Sheet 1 of the enclosed plans within the top left corner of the sheet that the proposed trees are to alternate Cupaniopsis anacardiodes and Tristania conferta along Blackrail Road. 12. The plans have been revised to remove any grading outside the property boundary in the northwestern corner of the site therefore we did not feel it necessary to go to the effort of locating the trees if they were to remain. Please see revised civil plans for updated grading. 13. Groundcover as well as shrub planting have been shown here. 14. The landscape plans have been revised to show screen shrubs in this area to buffer parking from Blackrail Road. Additionally, we have shown a section of the parking -9- '. relationship to Blackrail Road. Please see Sheet 4 of the enclosed conceptual landscape plan. 15. The fire protection plan has been revised to show more detailed hatching boundaries that tie back to the legend and requirements. The concept plan sheet 1 has been shown screened back on the Fire Protection Plan. 16. Columnar shrubs are used in the common areas for screening. Please see revised legend sheet 1 a. 17. Enlargements have been provided at each of the key activity or focal areas of the site including the main entry drive, pool and passive recreation area, new tot lot area, and overlook park area. 18. The entire passive park area is located under the existing SDG&E transmission line easement. Our plans are subject to compliance with their Guide for Encroachment species list. We have located some trees where you requested but they will not be the size you had in mind. The underlined species listed in plant legend are approved by SDG&E for use in their easements. A copy of the e-mail from Michael Williams at SDG&E is included with portions of the guide and approved species. His phone number, if you need to reach him with any questions, is 858-654-1201. 19. We could not add trees to this location due to the fact that they would fall within the Cal Trans 330' site distance easement. If it is acceptable to the City to locate trees within this easement, we will gladly revise the plan to show them as requested. 20. The Fire Protection Plan has been revised to correctly delineate and hatch the fire suppression zones. Please see Sheets 3 & 5 of the enclosed landscape plans. 21. Red-line plans are being returned to you as part of the re-submittal package as well as the e-mail from Sempra Energy. FIRE: ISSUES OF CONCERN 1. Pursuant to our review of the applicable Building and Fire Codes, the project meets or exceeds all of the minimum requirements for access, fire suppression and no building is larger than ten thousand (10,000) square feet. Based upon our review we have not included automatic fire sprinklers as part of the proposed project. We are willing to discuss your interpretation of the codes for the requirement of fire sprinklers, however, the applicant strongly feels that the system is not required. 2. All streets will be recorded as fire lanes and subject to the restrictions and enforcements afforded to this designation. 3. Parking located along Private Drives "B" and "C" is only proposed within parking bays outside of the twenty-four (24) foot drive aisle. The remainder of the private drives, along with the bulb at the end of Private Street "A" will be designated as a no parking zone. -10- ... ~ ' . . c If you have any questions or need any additional information, please feel free to contact myself at (760) 438-4090 ext 104 or e-mail me at bennett((J;jhenthorn.com. Sincerely, Senior Planner encl. Resubmittal Package-Muroya Subdivision, CT 06-2 7 /CP 06-19 cc: April Tornillo, Taylor Woodrow Homes, Inc Marybeth Murray, Hunsaker & Associates Christopher Gustard, GMP, Inc Roy Capitan, Robert Hidey Architects file -11- )HA!BDB/Muroya Rc>uh 0 0 CALIFORNIA INDIAN LEGAL SERVICES Escondido Office 609 South Escondido Boulevard, Escondido, CA 92025 +Phone 760/746-8941 +Fax 760/746-1815 www.calindian.org + contactCILS@calindian.org BISHOP EUREKA ESCONDIDO April 11, 2007 WA FACSIMILE (760-602-8559)AND U.S. MAIL Mr. Jason Goff City of Carlsbad Planning Department 1635 Faraday Avenue Carlsbad, CA 92008 Re: Muroya Subdivision Dear Mr. Goff: OAKLAND SANTA ROSA WASHINGTON, D.C. My office represents the San Luis Rey Band of Mission Indians. This letter is in response to your request of January 22, 2007 for consultation with the Band pursuant to SB 18. The San Luis Rey Band does wish to enter into formal consultation with the City of Carlsbad regarding the above project and Specific Plan. The Tribe has already received a copy of the cultural resources assessment. In addition, based on the information contained in the cultural resources assessment by Michael Brandman Associates, the project area is considered to be "moderately to highly sensitive with regard to cultural resources." See page 31 of the Phase 1 Cultural Resources Assessment. In addition, the Assessment recommends that Native American monitoring take place during any ground disturbing activities. See page 32. Based on the likelihood that cultural resources may be found and disturbed during the grading process, the San Luis Rey Band specifically requests that a formal Pre-Excavation Agreement be a mandatory requirement for the grading permit in this project. The Agreement will formalize the treatment of human remains and cultural items, as well as describe the monitoring services provided by the Tribe for the project, including compensation for the monitors at the developer's expense. Letter to Mr. Jason Goff Re: Muroya Subdivision April 12, 2007 Page 2 0 ------~~-~--· -·------------- 0 If you have any questions, please feel free to contact me at (760) 746-8941. To schedule the SB 18 consultation, I suggest that you contact Carmen Mojado, Secretary of Government Relations for the Band. She can be reached at (760) 724-8505. I look forward to working with you and the City of Carlsbad on this project. Sincerely, CALIFORNIA INDIAN LEGAL SERVICES ~~ Staff Attorney cc: Carmen Mojado (via facsimile) California Indian Legal Services 609 S. Escondido Blvd. • Escondido, CA 92025 Mr. Jason Goff City of Carlsbad Planning Department 1635 Faraday Avenue Carlsbad, CA 92008 Tribal Council Russell Romo Captain Carmen Mojado Secretary of Gaoernment Relations Charlotte Herrera Secretary of the Treasury Tom Beltran Secretary of Economic Development AI Cerda Secretary of Tribal Ethics and Infonnation OaraGuy Tribal Elder Henry Contreras Council Member Mel Vernon Council Member Mary Lou Beltran Council Member Carrie Lopez Tribal Advisor Merri Lopez, Esq. Tribe Legal Adviser Contact information 1889 Sunset Drive Vista, CA 92081 Tel: (760) 724-8505 Fax: (760) 724-2172 Revised: 01105 RE: The SAN LUIS REY BAND OF MISSION INDIANS 1889 Sunset Drive Vista, Ca 92081 Site Tel: (760) 724-8505 Fax: (760) 724-2172 . c./. does onsultati>on'·' · h ·bhe ~ regarding the above referenced pr Ject and Specific Plan. Please send us a copy of your cultural resources . report. The -----------------------------------------------------------------;;:-('toes not wish to enter into a formal consultat1.on w1.th~e -- regarding the above referenced p~aject and Specific Plan. We understand that this does not limit our ability to comment or claim any arifacts or cultural articles if they are found during excavation or any ground disturbance. The San Luis Rey Band is to a monitor to the project. a~~~~ J/J I February 21 , 2007 Jason Goff, Associate Planner City of Carlsbad 1635 Faraday Ave. Carlsbad, CA 92008 Re: Senate Bill 18 Consultation Re: Muroya Subdivision Dear Mr. Goff: This letter is in response to your request for Native American consultation on the above- referenced project. We respond to these requests on behalf of Robert Smith, Chairman of the Pal a Band of Mission Indians. Because this project takes place outside the traditional areas of residence of the people of Pala, we have a low level of concern regarding possible areas of cultural sensitivity. However, this should not be construed as indicating that no cultural resources or traditional cultural properties are present in this location. Areas of significance may be identified by other concerned bands, or revealed in the course of project construction. The Pal a Band of Mission Indians stands behind any assertions made by other bands that there are significant resources within the project area, should such assertions be made. Furthermore, we feel that any project of this size would benefit from the presence of Native American monitors during any ground-disturbing activities. We appreciate being made aware of this project and having the opportunity to comment. Shasta C. Gaughen, MA, ABD Acting Director 35008 Pala Temecula Road PMB 445 Pala, CA 92059 760-742-1590 [phone] 760-742-4543 [fax] January 31, 2007 0 City Kwaaymil Laguna Band of Mission Indians Carmen Lucas PO Box 775 Pine Valley, CA 91962 0 F ll [,;COPY of Carlsbad lifafllllllli•i•X§.fllll·'4111 SUBJECT: SENATE BILL 18 CONSULTATION RE: MUROYA SUBDIVISION -GPA 06- 09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 Dear Lucas: In accordance with the prov1s1ons of Senate Bill 18, the purpose of this letter is to initiate consultation with the Native American tribes, as identified by the Native American Heritage Commission, regarding the proposed Muroya Subdivision project located in the City of Carlsbad, California. Project Description: The proposed Muroya Subdivision is located on a 20.27 -acre site in the southwest quadrant of the City of Carlsbad, west of Black Rail Road, north of Aviara Parkway and south of Corte Orchidia. A General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit are being requested for a proposed residential subdivision consisting of 37 detached condominium units clustered in the northern and eastern portions of the 20.27-acre site. The project site is currently operating as a palm tree nursery with associated greenhouses and equipment sheds, and the property owner's personal residence. The majority of the site is encumbered by steep slopes and natural habitat. The proposed project intends to subdivide the subject site into 5 lots, with one lot preserving the current property owners existing residence, and the remaining lots for residential development and open space. The current General Plan Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with a Zoning classification of L-C (Limited Control). The General Plan Amendment will change the two (2) proposed open space lots from RLM to OS (Open Space) and the proposed residential lots from RLM to RM (Residential Medium Density, 4- 8 dwelling units per acre). Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots will change from L-C to OS (Open Space) and the zoning for the residential lots will change from L-C to RO-M (Residential Density-Medium). Cultural Resources Assessment: A Phase I Cultural Resources Assessment has been conducted by Michael Brandman Associates for the proposed project (January 4, 2007). The results of their survey indicate a single prehistoric isolated find, a previously known prehistoric site and no historical cultural resources. MBA recommends that cultural resource monitoring take place during all ground-disturbing activities 1635 Faraday Avenue • Carlsbad, CA 92008-7314.,. (760) 602-4600" FAX (760) 602-8559 • www.ci.carlsbad.ca.us @ \ 1 .·SENATE BILL 18 CONSCrATION RE: MUROYA SUBDIVISIO~PA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 JANUARY 31, 2007 PAGE2 associated with the proposed development, and that a monitoring program be developed prior to any grading within the project area. A copy of the cultural resources study has been sent to Mr. Mark Mojado, San Luis Rey Band of Mission Indians. Notice of Completion: The City of Carlsbad is currently in the process of reviewing the proposed Muroya Subdivision project. When the environment review for the project is complete, the City will issue a Notice of Completion in accordance with CEQA Guidelines. Requested Deadline: Pursuant to Government Code §65352.3(a)(2), please respond within 90 days of receipt of this notice in the event your tribe wishes to consult with the City regarding this matter. Please contact: Jason Goff Associate Planner City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 If you have any questions regarding this letter please contact me at (760) 602-4643. Sincerely, ~~ J:h/J .. 1/__l (/" f( JASON GOFF Associate Planner Attachments: Location Map Proposed General Plan and Zone Change Exhibit January 31, 2007 0 City San Pasqua! Band of Mission Indians Allen E. Lawson, Chairperson PO Box 365 Valley Center, CA 92082 8.• I . Df. 0 FILE COPY of Carlsbad IQfUUUI;t~I•X§.Liiii•«§;tl SUBJECT: SENATE BILL 18 CONSULTATION RE: MUROYA SUBDIVISION -GPA 06- 09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 Dear Mr. Lawson: In accordance with the prov1s1ons of Senate Bill 18, the purpose of this letter is to initiate consultation with the Native American tribes, as identified by the Native American Heritage Commission, regarding the proposed Muroya Subdivision project located in the City of Carlsbad, California. Project Description: The proposed Muroya Subdivision is located on a 20.27 -acre site in the southwest quadrant of the City of Carlsbad, west of Black Rail Road, north of Aviara Parkway and south of Corte Orchidia. A General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit are being requested for a proposed residential subdivision consisting of 37 detached condominium units clustered in the northern and eastern portions of the 20.27-acre site. The project site is currently operating as a palm tree nursery with associated greenhouses and equipment sheds, and the property owner's personal residence. The majority of the site is encumbered by steep slopes and natural habitat. The proposed project intends to subdivide the subject site into 5 lots, with one lot preserving the current property owners existing residence, and the remaining lots for residential development and open space. The current General Plan Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with a Zoning classification of L-C (Limited Control). The General Plan Amendment will change the two (2) proposed open space lots from RLM to OS (Open Space) and the proposed residential lots from RLM to RM (Residential Medium Density, 4- 8 dwelling units per acre). Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots will change from L-C to OS (Open Space) and the zoning for the residential lots will change from L-C to RO-M (Residential Density-Medium). Cultural Resources Assessment: A Phase I Cultural Resources Assessment has been conducted by Michael Brandman Associates for the proposed project (January 4, 2007). The results of their survey indicate a single prehistoric isolated find, a previously known prehistoric site and no historical cultural resources. MBA recommends that cultural resource monitoring take place during all ground-disturbing activities 1635 Faraday Avenue • Carlsbad, CA 92008-7314 .. (760) 602-4600"' FAX (760) 602-8559 .. www.ci.carlsbad.ca.us @ -. .. T~·i·~ SENATE ~IL;,L,18 CONSQATION RE: MUROYA SUBDIVISIO~PA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 JANUARY 31, 2007 PAGE2 associated with the proposed development, and that a monitoring program be developed prior to any grading within the project area. A copy of the cultural resources study has been sent to Mr. Mark Mojado, San Luis Rey Band of Mission Indians. Notice of Completion: The City of Carlsbad is currently in the process of reviewing the proposed Muroya Subdivision project. When the environment review for the project is complete, the City will issue a Notice of Completion in accordance with CEQA Guidelines. Requested Deadline: Pursuant to Government Code §65352.3(a)(2}, please respond within 90 days of receipt of this notice in the event your tribe wishes to consult with the City regarding this matter. Please contact: Jason Goff Associate Planner City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 If you have any questions regarding this letter please contact me at (760) 602-4643. Sincerely, . i)/1 j I (5Y~ff , JASON GOFF . Associate Planner Attachments: Location Map Proposed General Plan and Zone Change Exhibit January 31, 2007 0 Cit San Luis Rey Band of Mission Indians Russell Rome, Chairman 12064 Old Pomerado Road Poway, CA 92064 of SUBJECT: SENATE BILL 18 CONSULTATION RE: MUROYA SUBDIVISION -GPA 06- 09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 Dear Mr. Rome: In accordance with the prov1s1ons of Senate Bill 18, the purpose of this letter is to initiate consultation with the Native American tribes, as identified by the Native American Heritage Commission, regarding the proposed Muroya Subdivision project located in the City of Carlsbad, California. Project Description: The proposed Muroya Subdivision is located on a 20.27-acre site in the southwest quadrant of the City of Carlsbad, west of Black Rail Road, north of Aviara Parkway and south of Corte Orchidia. A General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit are being requested for a proposed residential subdivision consisting of 37 detached condominium units clustered in the northern and eastern portions of the 20.27-acre site. The project site is currently operating as a palm tree nursery with associated greenhouses and equipment sheds, and the property owner's personal residence. The majority of the site is encumbered by steep slopes and natural habitat. The proposed project intends to subdivide the subject site into 5 lots, with one lot preserving the current property owners existing residence, and the remaining lots for residential development and open space. The current General Plan Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with a Zoning classification of L-C (Limited Control). The General Plan Amendment will change the two (2) proposed open space lots from RLM to OS (Open Space) and the proposed residential lots from RLM to RM (Residential Medium Density, 4- 8 dwelling units per acre). Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots will change from L-C to OS (Open Space) and the zoning for the residential lots will change from L-C to RO-M (Residential Density-Medium). Cultural Resources Assessment: A Phase I Cultural Resources Assessment has been conducted by Michael Brandman Associates for the proposed project (January 4, 2007). The results of their survey indicate a single prehistoric isolated find, a previously known prehistoric site and no historical cultural resources. MBA recommends that cultural resource monitoring take place during all ground-disturbing activities 1635 Faraday Avenue'" Carlsbad, CA 92008-7314 e (760) 602-4600 ~FAX (760) 602-8559 • www.ci.carlsbad.ca.us @ :~· . ' . ,.,_ • .., • .LJ SENATE BILL 18 CONS~ATION RE: MUROYA SUBDIVISIOrMPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-1 0/HMPP 07-02 JANUARY 31, 2007 PAGE2 associated with the proposed development, and that a monitoring program be developed prior to any grading within the project area. A copy of the cultural resources study has been sent to Mr. Mark Mojado, San Luis Rey Band of Mission Indians. Notice of Completion: The City of Carlsbad is currently in the process of reviewing the proposed Muroya Subdivision project. When the environment review for the project is complete, the City will issue a Notice of Completion in accordance with CEQA Guidelines. Requested Deadline: Pursuant to Government Code §65352.3(a)(2), please respond within 90 days of receipt of this notice in the event your tribe wishes to consult with the City regarding this matter. Please contact: Jason Goff Associate Planner City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 If you have any questions regarding this letter please contact me at (760) 602-4643. Sincerely, c;Y~J) .. ~ JASON GOFF Associate Planner Attachments: Location Map Proposed General Plan and Zone Change Exhibit 0 Cit January 31, 2007 Kurneyaay Cultural Repatriation Committee Steve Banegas, Spokesperson 1 095 Sarona Road Lakeside, CA 92040 of SUBJECT: SENATE BILL 18 CONSULTATION RE: MUROYA SUBDIVISION -GPA 06- 09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 Dear Mr. Banegas: In accordance with the prov1s1ons of Senate Bill 18, the purpose of this letter is to initiate consultation with the Native American tribes, as identified by the Native American Heritage Commission, regarding the proposed Muroya Subdivision project located in the City of Carlsbad, California. Project Description: The proposed Muroya Subdivision is located on a 20.27-acre site in the southwest quadrant of the City of Carlsbad, west of Black Rail Road, north of Aviara Parkway and south of Corte Orchidia. A General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit are being requested for a proposed residential subdivision consisting of 37 detached condominium units clustered in the northern and eastern portions of the 20.27-acre site. The project site is currently operating as a palm tree nursery with associated greenhouses and equipment sheds, and the property owner's personal residence. The majority of the site is encumbered by steep slopes and natural habitat. The proposed project intends to subdivide the subject site into 5 lots, with one lot preserving the current property owners existing residence, and the remaining lots for residential development and open space. The current General Plan Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with a Zoning classification of L-C (Limited Control). The General Plan Amendment will change the two (2) proposed open space lots from RLM to OS (Open Space) and the proposed residential lots from RLM to RM (Residential Medium Density, 4- 8 dwelling units per acre). Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots will change from L-C to OS (Open Space) and the zoning for the residential lots will change from L-C to RO-M (Residential Density-Medium). Cultural Resources Assessment: A Phase I Cultural Resources Assessment has been conducted by Michael Brandman Associates for the proposed project (January 4, 2007). The results of their survey indicate a single prehistoric isolated find, a previously known prehistoric site and no historical cultural resources. MBA recommends that cultural resource monitoring take place during all ground-disturbing activities 1635 Faraday Avenue" Carlsbad, CA 92008-7314 • (760) 602-4600 <>FAX (760) 602-8559 '"www.ci.carlsbad.ca.us @ ,......, ~ SENATE BILL 18 CONStkrATION RE: MUROYA SUBDIVISIO~PA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 JANUARY 31, 2007 PAGE2 associated with the proposed development, and that a monitoring program be developed prior to any grading within the project area. A copy of the cultural resources study has been sent to Mr. Mark Mojado, San Luis Rey Band of Mission Indians. Notice of Completion: The City of Carlsbad is currently in the process of reviewing the proposed Muroya Subdivision project. · When the environment review for the project is complete, the City will issue a Notice of Completion in accordance with CEQA Guidelines. Requested Deadline: Pursuant to Government Code §65352.3(a)(2), please respond within 90 days of receipt of this notice in the event your tribe wishes to consult with the City regarding this matter. Please contact: Jason Goff Associate Planner City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 If you have any questions regarding this letter please contact me at (760) 602-4643. Sincerely, v~ JASON GOFF Associate Planner Attachments: Location Map Proposed General Plan and Zone Change Exhibit January 31, 2007 0 City Pala Band of Mission Indians Robert Smith, Chairperson 12196 Pala Mission Rd.; PMB 50 Pala, CA 92059 0 flLE COP~ J.·l·Ol of Carlsbad I #liFt h h t;t.M •A§ ·fill ilel§ hI SUBJECT: SENATE BILL 18 CONSULTATION RE: MUROYA SUBDIVISION -GPA 06- 09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 Dear Mr. Smith: In accordance with the prov1s1ons of Senate Bill 18, the purpose of this letter is to initiate consultation with the Native American tribes, as identified by the Native American Heritage Commission, regarding the proposed Muroya Subdivision project located in the City of Carlsbad, California. Project Description: The proposed Muroya Subdivision is located on a 20.27 -acre site in the southwest quadrant of the City of Carlsbad, west of Black Rail Road, north of Aviara Parkway and south of Corte Orchidia. A General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit are being requested for a proposed residential subdivision consisting of 37 detached condominium units clustered in the northern and eastern portions of the 20.27 -acre site. The project site is currently operating as a palm tree nursery with associated greenhouses and equipment sheds, and the property owner's personal residence. The majority of the site is encumbered by steep slopes and natural habitat. The proposed project intends to subdivide the subject site into 5 lots, with one lot preserving the current property owners existing residence, and the remaining lots for residential development and open space. The current General Plan Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with a Zoning classification of L-C (Limited Control). The General Plan Amendment will change the two (2) proposed open space lots from RLM to OS (Open Space) and the proposed residential lots from RLM to RM (Residential Medium Density, 4- 8 dwelling units per acre). Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots will change from L-C to OS (Open Space) and the zoning for the residential lots will change from L-C to RO-M (Residential Density-Medium). Cultural Resources Assessment: A Phase I Cultural Resources Assessment has been conducted by Michael Brandman Associates for the proposed project (January 4, 2007). The results of their survey indicate a single prehistoric isolated find, a previously known prehistoric site and no historical cultural resources. MBA recommends that cultural resource monitoring take place during all ground-disturbing activities 1635 Faraday Avenue • Carlsbad, CA 92008-7314" (760) 602-4600 .. FAX (760) 602-8559 "www.ci.carlsbad.ca.us @ ~ .~ S~Mle_,BJLL 18 CONSLMATION RE: MUROYA SUBDIVISJON-......GPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 JANUARY 31, 2007 PAGE2 associated with the proposed development, and that a monitoring program be developed prior to any grading within the project area. A copy of the cultural resources study has been sent to Mr. Mark Mojado, San Luis Rey Band of Mission Indians. Notice of Completion: The City of Carlsbad is currently in the process of reviewing the proposed Muroya Subdivision project. When the environment review for the project is complete, the City will issue a Notice of Completion in accordance with CEQA Guidelines. Requested Deadline: Pursuant to Government Code §65352.3(a)(2), please respond within 90 days of receipt of this notice in the event your tribe wishes to consult with the City regarding this matter. Please contact: Jason Goff Associate Planner City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 If you have any questions regarding this letter please contact me at (760) 602-4643. Sincerely, ~~L~ ~v-~-~~rr JASON GOFF Associate Planner Attachments: Location Map Proposed General Plan and Zone Change Exhibit January 31, 2007 0 City San Luis Rey Band of Mission Indians Carmen Mojado, Co-Chair 1889 Sunset Dr. Vista, CA 92081 4· 1·0":1- 0 FILE COPY of Carlsbad IQ@Uhii;t.i•J§.Iblll,t§;tl SUBJECT: SENATE BILL 18 CONSULTATION RE: MUROYA SUBDIVISION -GPA 06- 09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 Dear Ms. Mojado: In accordance with the prov1s1ons of Senate Bill 18, the purpose of this letter is to initiate consultation with the Native American tribes, as identified by the Native American Heritage Commission, regarding the proposed Muroya Subdivision project located in the City of Carlsbad, California. Project Description: The proposed Muroya Subdivision is located on a 20.27-acre site in the southwest quadrant of the City of Carlsbad, west of Black Rail Road, north of Aviara Parkway and south of Corte Orchidia. A General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit are being requested for a proposed residential subdivision consisting of 37 detached condominium units clustered in the northern and eastern portions of the 20.27-acre site. The project site is currently operating as a palm tree nursery with associated greenhouses and equipment sheds, and the property owner's personal residence. The majority of the site is encumbered by steep slopes and natural habitat. The proposed project intends to subdivide the subject site into 5 lots, with one lot preserving the current property owners existing residence, and the remaining lots for residential development and open space. The current General Plan Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with a Zoning classification of L-C (Limited Control). The General Plan Amendment will change the two (2) proposed open space lots from RLM to OS (Open Space) and the proposed residential lots from RLM to RM (Residential Medium Density, 4- 8 dwelling units per acre). Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots will change from L-C to OS (Open Space) and the zoning for the residential lots will change from L-C to RD-M (Residential Density-Medium). Cultural Resources Assessment: A Phase I Cultural Resources Assessment has been conducted by Michael Brandman Associates for the proposed project (January 4, 2007). The results of their survey indicate a single prehistoric isolated find, a previously known prehistoric site and no historical cultural resources. MBA recommends that cultural resource monitoring take place during all ground-disturbing activities 1635 Faraday Avenue ., Carlsbad, CA 92008-7314 s (760) 602-4600 ., FAX (760) 602-8559 s www.ci.carlsbad.ca.us @ .,.·-· . ... . .. . . . ~ . I"' ~ SENATE BILL 18 CONS~ATION RE: MUROYA SUBDIVISION~PA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 JANUARY 31 , 2007 PAGE2 associated with the proposed development, and that a monitoring program be developed prior to any grading within the project area. A copy of the cultural resources study has been sent to Mr. Mark Mojado, San Luis Rey Band of Mission Indians. Notice of Completion: The City of Carlsbad is currently in the process of reviewing the proposed Muroya Subdivision project. When the environment review for the project is complete, the City will issue a Notice of Completion in accordance with CEQA Guidelines. Requested Deadline: Pursuant to Government Code §65352.3(a)(2), please respond within 90 days of receipt of this notice in the event your tribe wishes to consult with the City regarding this matter. Please contact: Jason Goff Associate Planner City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 If you have any questions regarding this letter please contact me at (760) 602-4643. ~~~ (~SONGOFF ~ Associate Planner Attachments: Location Map Proposed General Plan and Zone Change Exhibit January 25, 2007 c City Jack Henthorn & Associates Bryan Bennett, Senior Planner 5365 Avenida Encinas, Suite A Carlsbad,CA 92008 I ·&v'l 0·7 0 flli ~lJPY of Carlsbad lij@Jelhlei•i•J§.ffiillel§bl SUBJECT: GPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06- 10/HMPP 07-02-MUROYA SUBDIVISION The following is a list of items which are considered to be supplemental to the previous letter of completeness dated January 12, 2007. In that letter it was stated that the Engineering Department comments would follow under separate cover. Please find those comments attached belowt If you should have any questions or wish to set up a meeting to discuss your application, please contact Jason Goff at (760) 602-4643. Sincerely, DON NEU Acting Planning Director c: Gary Barberio, Team Leader Clyde Wickham, Project Engineer File Copy Data Entry 1635 Faraday Avenue • Carlsbad, CA 92008-7314 ~ (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us (i} ,...., '~ ; GPA 06-09/ZC 06-08/LCP):-66-09/CT 06-27/CP 06-19/COP 06-32fl'!i6P 06-10/HMPP 07·02 • Muroya Subdivision January 25, 2007 Pa e2 Issue Items Engineering: Engineering Department staff has completed their review of the above·referenced project for application completeness. The application and plans submitted for this proposed project are from an Engineering perspective considered complete with issues to be resolved prior to support of the application(s). The following issues need to be resolved prior to resubmittal: 1. Complete the project identification numbers (CT, COP, CP, LCPA ... etc on all appropriate sheets and plans of this application. 2. Please add CFS and drainage basin information to the cover sheet (this avoids having to gather additional information for the staff report at the last minute), the project ADT, Water (GPM), and Fire Flow (GPM) demand and sewer information should also be provided. It's easier if all of the data information is in 1 table or group of notes. 3. Please add remedial estimated grading quantities and limits of over excavation as identified in the geotechnical report dated 4/26/2006. 4. The Preliminary Geotechnical Report (dated 4/26/2006) identified several areas of Debris Fill, Undocumented Fill, Colluvium, and generally undesirable geologic conditions requiring remedial grading to support the proposed development. Please show the full extent of over cut, offsite slopes, keys or buttresses anticipated to provide a stable pad and building foundation. 5. The north side of this subdivision should be consistent with City Standard GS-14 & GS· 15. Provide slope setbacks, brow ditches and subdivision boundary condition. Slopes and drainage is usually the main issue with abutting developments. 6. The condominium exclusive use areas should allow for vehicle maneuvering and utility services, without encroachment. The courtyard, access, and utilities should be within the general access and utility portion of the subdivision as opposed to within exclusive use areas. 7. The proposed street and access plan for Units 1-12 is extremely congested and difficult to maneuver. The minimum street section for Street "B" should be 34' within a 56' General Utillity and access Easement, similar to Street "A". Private Street "C" should also be a little wider at the intersection of Black Rail Road and Approach to Private Street "A". Our Hillside Ordinance allows for a 32' wide street, single loaded which would work fine between units 34 and 35. 8. The perpendicular parking and perpendicular RV parking on Street "8" with only 24' AC Pavement (plan view, sheet 4) is difficult to support. 9. Please show water and sewer meters and cleanouts to each unit on the tentative map I site plan. Utility boxes, service locations and gas meters will also be a concern that should be considered in advance of TM approval. The exclusive use areas with this in mind needs to be re-plotted. ' --··------------------------------------ • GPA 06-09/ZC 06-08/LCPAQ-09/CT 06-27/CP 06-19/CDP 06-32/..Q 06-10/HMPP 07-02- Muroya Subdivision January 25, 2007 Pa e 3 10. Please submit support or easement information to aUow the offsite connection to Nightshade road. Also provide calculations to support the size and capacity of the facility downstream to accommodate this project. 11. Please follow proposed drainage downstream to determine capacity or mitigation to accommodate the proposed project. Check-dams or downstream mitigation to address the additional runoff and velocity should be shown. Perhaps a basin (Structural BMP) and safe overflow structure could be provided on Lot 4. 12. Please add SWPP notes and structural BMP's to the Tentative Map. Indicate all BMP's will be maintained by the Property owner or HOA. Provide specific product or design specs for proposed water treatment unit(s). 13. Provide a cross section of the parking and RV parking portion of this site. Identify the typical structural section proposed for truck areas as ~ell as for vehicle and parking areas. 14. The street lights shown on the tentative map appear different than what has been constructed and in place. There are no street lights proposed along the project frontage, please take a look at this and revise if necessary. This review does not constitute a complete review of the proposed project and additional items of concern, as well as comments on technical and design issues, will be identified upon submission of the above items. If you or the applicant has any questions regarding these comments, please contact Clyde Wickham at (760) 602-2742. ~----------·~--------------~,------~I~·~ZL·O~ G LOCAL GOVERNMENT ..: FILE 0 p y TRIBAL CONSULTATION LIST REQUEST NATIVE AMERICAN HERITAGE COMMISSION 915 CAPITOL MALL, ROOM 364 SACRAMENTO, CA 95814 (916) 653-4082 (916) 657-5390 -Fax DATE: January 22,2007 PROJECT TITLE: Muroya Subdivision-GPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06- 19/CDP 06-32/HDP 06-10/HMPP 07-02 LEAD AGENCY: ""'C"-"ityJ._.;!...of,_,C,a~r"""ls"""ba""d'-----­ PHONE: (760) 602-4643 STREET ADDRESS: 1635 Faraday Avenue CITY: Carlsbad CA ZIP: 92008 Specific Area Subject To Proposed Action Carlsbad, CA San Diego County Local Action Type: CONTACT PERSON: Jason Goff FAX: (760) 602-8559 APN: 215-040-03 0 General Plan 0 General Plan Element 0 Specific Plan D Master Plan [gl General Plan Amendment 0 Specific Plan Amendment 0 Pre-planning Outreach Activity Project Description: The proposed Muroya Subdivision is located on a 20.27-acre site in the southwest quadrant of the City of Carlsbad, west of Black Rail Road, north of Aviara Parkway and south of Corte Orchidia. A General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit are being requested for a proposed residential subdivision consisting of 37 detached condominium units clustered in the northern and eastern portions of the 20.27-acre site. The project site is currently operating as a palm tree nursery with associated greenhouses and equipment sheds, and the property owner's personal residence. The majority of the site is encumbered by steep slopes and natural habitat. The proposed project intends to subdivide the subject site into 5 lots, with one lot preserving the current property owners existing residence, and the remaining lots for residential development and open space. The current General Plan Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with a Zoning classification of L-C (Limited Control). The General Plan Amendment will change the two (2) proposed open space lots from RLM to OS (Open Space) and the proposed residential lots from RLM to RM (Residential Medium Density, 4-8 dwelling units per acre). Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots will change from L-C to OS (Open Space) and the zoning for the residential lots will change from L-C to RD-M (Residential Density- Medium). Location Map -Attached NAHC Use Only Date Received:, _________ _ Date Completed ________ _ Native American Tribal Consultation lists are only applicable for consulting with California Native American Tribes per Government Code Section 65352.3. \-- f-- t= f-- 0 GENERAL LAND PLAN ~USE R AC L-C ZONING OS I VAC I 0-S 11.5AC OS I VAC I P-C GENERAL PLAN DESIGNATIONS RLM -Residential Low-Medium RM -Residential Medium RH -Residential High RL-Residential Low OS -Open Space RH/C/0-Mixed Use PI • Planned Industrial MUROY A PROPERTY GENERAL PLAN AMENDMENT & ZONE CHANGE MAP )ACK HENTHORN & ASSOCIATES ZONING CATEGORIES R-1 ·One Family Residential RD-M · Residential Density-Multiple R-E · Rural Residential Estate R·A-Residential Agricultural L-C -Limited Control 0 -Qualified Overlay Zone OS · Open Space M · Industrial -r --r --+ EXISTING LAND USE VAG-Vacant DEV · Developed 01/25/2007 14:05 FAX 916 657 5390 NARC STA71i Qf a&IJfPIMt NATlVE AMERICAN HERITAGE COMMISSION tt& CAPI1'0L MALl.., ROOII S64 SACAAMINTO, CA .a14 (818) 65H251 FU (811) 867-53110 W.b life ~·rl.llh~ot.g.ov -all: da_nahC.paclll:lll.not January 25, 2007 Mr. Jason Goff CITY OF CARUIIAD 1635 Faraday Avenue Carlsbad, CA 92008 Sent by FAX to: 760-602--8559 Number of pages: 2 ~001 Ampfd ,. ........... GfyNnpc Re; Ttibal Consyltf!!tion eer SB 18/Sacre<f llnds File Seirch for Pr<ii91· Muroya Subdlvlelon - QPA 08-0tJZC 06-0IJI.CPA 08::()9/CJ 06:27/CP Q6-11!CDP OH2JHDP 09-1QJHMPP 0'7..02; City of Carlsbad; San Diego County. Califomja Dear Mr. Goff: . Government Code §65352..3 requires ~~ govemments to consuft wilh Callfomla NatiVe American 1rlbes identified by the Native American Heritage Commission (NAHC) for the purpox of protecting, and/or mitigating Impacts to cultUral places. Attached Is a NatiVe Anwrican Tribal Con&uttatlon list of tribes with traditional lands or cultural places locilted within the 111qun18d plan boundaries. NI:Jte the attached form for combining the Sacred Lands file search with SS 18 Tribal Consultation Lists. As a part of conSUltation, the NAHC recommend$ that toc;al gowmrnent$ conduct record searches through the NAHC and Callfomla Historic Resources lnfonnation Syaem (CHRIS) to determine if any cultural places are located within the area(a) affected by the propOsed action. A NAHC Sacred lands File search was conducted based on the 10wnship, range, and section Information included in your request and no sites were found within the area of potential effect yoo id8mltled. However, local governmentS should be awar.1hat r.cord$ maintained by tile NAHC and CHRIS are not exhaustive, and a negative response to these &earches do" not preclude the existence of a cultural place. A tribe may be the only source of • infOrmation regarding the existence of a cultural place. I suggest you ~nsult with all of those on the accompanying Native AmeriCan Contacts liSt, which has been included separately. If they cannot supply information, they might recommend others with specific knowledge about cultural resources in your plan area. If a response has not been received within two weeks of notification, the Commission requests that you follow-up with a telephone call to ensure that the project information has been receiVed. If you receive notification of ._hange of addresses and phone numbers from Tribes, please notify me. With your assistance we are able to assure that our consultation list contains current information. It you have any QU&Itions, please comact me at ram Analyst Attachment: NatiVe American contacts 01/25/2007 14:05 FAX 916 657 5390 NAHC . ... NattW American Tribal Consultation Lis;J San Diego County I San Pasqual Band of Mission Indians Allen E. Lawson, Chairperson POBox365 Valley Center (760) 7 49-3200 ,CA 92082 Oiegueno (760) 749-3876 Fax v Kwaaymii Laguna Band of Mission Indians Carmen Lucas P.O. Box 775 Pine Valley , CA 91982 January 25, 2007 Pala Band of Mission Indians Robert Smith, Chairperson 12196 Pala Mission Rd.; PMB 50 Pala , CA 92059 Lulseno (760) 7 42-3784 Cupeno (760) 742-1411 Fax ~·· Kumeyaay Cultural Repatriation Committee Steve Banegas, Spokesperson 1095 Baron a Road Lakeside , CA 92040 ~002 Diegueno -Kwaaymii Diegueno/Kumeyaay (619) 709-4207 San Luis Rey Band of Mission Indians Russell Romo, Chairman 12064 Old Pomerado Road "'/,/ Poway , CA 92064 Luiseno (858) 748-1586 Thlt IIIDI 1c current onty u of the date of this document. (619) 443-6612 (619) 443-D681 FAX San Luis Rey Band of Mission Indians Carmen Mojado, Co-Chair 1889 Sunset Dr. Vista , CA 92081 Luiseno Dllb'lbUtlon of tid& liSt e10e1 not relieve any pereon of etatutory ~lblllty ae deftmcl In Section 7050.5 Of 'lhe Health and 5llfMy Code, Sedlon 6097.94 of 1M Publlo ~Code and section 5097.98 Df the Public Reaource$ Code. 1'hl8 list Is eppl(ceble only for conaunatlon with Nadve American tribe$ under Government COCio Section 85352.3. SENC"ER: con1PLETE THIS SEC N • Complete items 1, 2, and 3. Alst. _,mplete item 4 if Restricted Delivery is desired. • Print your name and address on the reverse so that we can return the card to you. • Attach this card to the back of the mailpiece, or on the front if space permits. 1. Article Addressed to: SAN LUIS REY BAND OF MISSION INDIANS MR. MARK MOJADO 1889 SUNSET DRIVE VISTA, CA 92083 COMPLETE THIS SECTION ON DEL/II qy A. Slg~nature X //~ ..--::.o. 0Agent r ./ ,,._. .._ D Addressee B. Received by (Printed Name) I C. Date of Dellyery D. Is delivery address different from Item 1? D Yes If YES, enter delivery address below: D No 3.iEType rtlfled Mall 0 Express Mall Registered D Retum Receipt for Merchandise 0 Insured Mall 0 C.O.D. 4. Restricted Delivery? (Extra Fee) 0 Yes 2. Article Number (rransfer from service label) 7005 2570 0001 6685 2965 PS Form 3811, February 2004 Domestic Retum Receipt U.S. Postal ServicerM · CERTIFIED MAlLM RECEI. (Domestic Mail Only; No Insurance Cover. rovided) PS Form 3800, June 2002 See Reverse for Instructions • l • "' January 22, 2007 • c City San Luis Rey Band Of Mission Indians Mr. Mark Mojado 1889 Sunset Drive Vista, CA 92083 I·U.·~ FILE COPY of Carlsbad IQFJellllli•i•J§.f!Jiilei§IJI SUBJECT: SENATE BILL 18 CONSULTATION RE: MUROYA SUBDIVISION -GPA 06- 09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 Dear Mr. Mojado: In accordance with the prov1s1ons of Senate Bill 18, the purpose of this letter is to initiate consultation with the San Luis Rey Band of Mission Indians tribe regarding the proposed Muroya Subdivision project located in the City of Carlsbad, California. Project Description: The proposed Muroya Subdivision is located on a 20.27-acre site in the southwest quadrant of the City of Carlsbad, west of Black Rail Road, north of Aviara Parkway and south of Corte Orchidia. A General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Subdivision Map, Condominium Permit, Coastal Development Permit, Hillside Development Permit and Habitat Management Plan Permit are being requested for a proposed residential subdivision consisting of 37 detached condominium units clustered in the northern and eastern • portions of the 20.27-acre site. The project site is currently operating as a palm tree nursery with associated greenhouses and equipment sheds, and the property owner's personal residence. The majority of the site is encumbered by steep slopes and natural habitat. The proposed project intends to subdivide the subject site into 5 lots, with one lot preserving the current property owners existing residence, and the remaining lots for residential development and open space. The current General Plan Land Use designation for the entire site is RLM (Residential Low-Medium Density, 0-4 dwelling units per acre) with a Zoning classification of L-C (Limited Control). The General Plan Amendment will change the two (2) proposed open space lots from RLM to OS (Open Space) and the proposed residential lots from RLM to RM (Residential Medium Density, 4- 8 dwelling units per acre). Zoning will also be amended to correspond with the associated General Plan Land Use Amendments. The zoning for the open space lots will change from L-C to OS (Open Space) and the zoning for the residential lots will change from L-C to RD-M (Residential Density-Medium). Cultural Resources Assessment: A Phase I Cultural Resources Assessment has been conducted by Michael Brand man Associates for the proposed project (January 4, 2007). The results of their survey indicate a single prehistoric isolated find, a previously known prehistoric site and no historical cultural resources. MBA recommends that cultural resource monitoring take place during all ground-disturbing activities associated with the proposed development, and that a monitoring program be developed prior to 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us <!) \! ; ' ~ • """" ~ .. SENATE BILL 18 CONSU~TATION RE: MUROYA SUBDIVISION'·-'.3PA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 JANUARY 22, 2007 PAGE2 any grading within the project area. A copy of the Phase I Cultural Resources Assessment is enclosed. Notice of Completion: The City of Carlsbad is currently in the process of reviewing the proposed Muroya Subdivision project. When the environment review for the project is complete, the City will issue a Notice of Completion in accordance with CEQA Guidelines. Requested Deadline: Pursuant to Government Code §65352.3(a)(2), please respond within 90 days of receipt of this notice in the event your tribe wishes to consult with the City regarding this matter. Please contact: Jason Goff Associate Planner City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 If you have any questions regarding this letter please contact me at (760) 602-4643. Sincerely, (7~4J JASON GOFF Associate Planner Attachments: Phase I Cultural Resources Assessment Location Map Proposed General Plan and Zone Change Map ., . . January 12, 2007 c City Jack Henthorn & Associates Bryan Bennett, Senior Planner 5365 Avenida Encinas, Suite A Carlsbad, CA, 92008 i·JJ./ v·:1 -'-' Fllt COPY of Carlsbad I#IJFJiJhih.M•X§·LJIII.t§bl· SUBJECT: GPA 06-09/ZC 06-08/LCPA 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02-MUROYA SUBDIVISION Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning Department has reviewed your General Plan Amendment, Zone Change, Local Coastal Program Amendment, Tentative Tract Map, Condominium Permit, Coastal Development Permit, and Hillside Development Permit, application file numbers, GPA 06-09, ZC 06-08, LCPA 06-09, CT 06-27, CP 06-19, COP 06-32 and HOP 06-10, as to their completeness for processing. The application is incomplete, as submitted. Attached are two lists. The first list is information which must be submitted to complete your application. This list of items must be submitted · directly to your staff planner by appointment. All list items must be submitted simultaneously and a copy of this list must be included with your submittals, including five (5) sets of plans. No processing of your application can occur until the application is determined to be complete. The second list is issues of concern to staff. When all required materials are submitted, the City has 30 days to make a determination of completeness. If the application is determined to be complete, processing for a decision on the application will be initiated. In addition, please note that you have six months from the date the application was initially filed, December 13, 2006, to either resubmit the application or submit the required information. Failure to resubmit the application or to submit· the materials necessary to determine your application complete shall be deemed to constitute withdrawal of the application. If an application is withdrawn or deemed withdrawn, a new application must be submitted. Please contact your staff planner, Jason Goff, at (760) 602-4643, if you have any questions or wish to set up a meeting to discuss the application. [e~ DON NEU Assistant Planning Director DN:JAGO:aw c: Gary Barberio, Team Leader Clyde Wickham, Project Engineer File Copy Data Entry 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us @ GPA ta:.(J9/ZC 06..:08/LC; 06-09/CT 06-27/CP 06-19/CDP 06~/HDP 06-10/HMPP 07-02-Muroya Subdivision January 12, 2007 Pa e2 LIST OF ITEMS NEEDED TO COMPLETE THE APPLICATION Planning: A. (City of Carlsbad Application Requirements FORM. 1 -Tentative Tract Maps, Condominium Permits & Coastal Development Permits) 1. Provide Project Compatibility Matrixes, which demonstrate project consistency with Planned Development Tables "C" (C.M.C. 21.45.060) and "D" (C.M.C. 21.45.070). 2. Label Black Rail Road on the vicinity map (revise all exhibits appropriately). 3. Add Habitat Management Plan Permit, file no. HMPP 07-02, to the map exhibits. 4. Provide a full size colored recycled water use area map (all areas proposed to be irrigated with recycled water must be clearly indicated on the map in color). 5. Provide photographs of the property from the north, south, east and west. Additionally, please also provide photographs of the site that are in a digital format. 6. Provide a completed Early Public Notic~ Package (specifically, provide the signed certification of posting form). 7. The Project qualifies as an "lnfill Residential Project" pursuant to Section II (D) of the City of Carlsbad Application Requirements. As such the following is required: a. The project site must be posted with notices pursuant to Planning Department Administrative Policy No. 37 (see attached), and b. Project photo-simulation exhibits must be completed and submitted to the Planning Department upon a determination that the project application is complete. The photo simulation exhibits should be scaled representations of the project, as viewed from adjacent streets and adjacent developed single-family residential properties. B. (City of Carlsbad Application Requirements FORM 2 -General Plan Amendments, Local Coastal Program Amendments & Zone Changes) 8. Provide a 1" = 500' exhibit of the subject property showing the requested General Plan, Zoning, and Local Coastal Program General Plan and Zoning designation(s) with the acreage involved. Also provide the surrounding General Plan, Zoning, and Local Coastal Program General Plan and Zoning designations and surrounding land uses. C. (City of Carlsbad Application Requirements FORM 4-Hillside Development Permits) 9. It is required that both the slope analysis and slope profile exhibits be stamped by either a registered landscape architect, civil engineer or land surveyor indicating the datum, source and scale of topographic data used in the slope analysis and slope profiles, and attesting to the fact that the slope analysis and slope profiles have been accurately .. ,I"'"' f"""', GPA 06-09/ZC 06-08/L~ 06-09/CT 06-27/CP 06-19/CDP 0~2/HDP 06-10/HMPP 07-02 -Muroya Subdivision January 12, 2007 Pa e3 calculated and identified according to the Hillside Development and Design Standards (C.M.C. Section 21.95.120). 10. Provide a Slope Edge Building Setback exhibit demonstrating project consistency with Section 21.95.120(1) of the Carlsbad Municipal Code. D. (Biological Resources Report) 11. In accordance with the recommendation of the Biological Resources Report (Dudek, December 2006), provide the subsequent biological resource surveys for special status plant species. As recommended, these surveys are to be prepared during the months of March and June of 2007 in order to capture the appropriate biological windows for each of the particular special status plant species discussed in the report. 12. The project will be required to pay habitat in lieu mitigation fees for Type "F" Habitat Groups in accordance with Table-11 of the Habitat Management Plan. The bio-report, on Pg. 29 under Section 6.0, indicates'that no mitigation is required for disturbed habitat, agriculture, ornamental planting and developed lands. Please note that "Disturbed Habitat" and "Agriculture" are considered a Group "F" Habitat category and subsequently are required to pay the appropriate habitat in lieu mitigation fee. Ornamental plantings fall under the category of developed land and are therefore not subject to the in lieu mitigation fee. Section 6 (Page 29) of the bio-report must be updated to account for the impacts and mitigation of Group "F" habitats. 13. Provide an additional section, in the bio-report which specifically discusses how the project complies with Management and Conservation Goals for HMP Species (D-97 through D-111). 14. Provide additional sections in the bio-report specifically discussing how the project addresses each of the five adjacency standards that are outlined in Pages F-16 through F-22 of the HMP. 15. The October 1st to April 1st rainy season grading activity prohibition is no longer in place as a result of updates to the NPDES standards and the Carlsbad Local Coastal Program. Please revise the bio-report accordingly. E. (Detailed Soils Testing and Analysis Report) 16. A detailed soils testing and analysis report shall be prepared for the project by a registered soils engineer. The report must be submitted to the City and the San Diego County Health Department for review and approval. The report shall evaluate the potential for soils contamination due to historic use, handling, or storage of agricultural chemicals restricted by the San Diego County Department of Health Services. The report shall also identify a ·range of possible mitigation measures to remediate any significant public health impacts if hazardous chemicals are detected at concentrations in the soil which would have a significant adverse effect on human health. GPA 06-09/ZC 06-08/LC& 06-09/CT 06-27/CP 06-19/CDP 0;?2/HDP 06-1 0/HMPP 07-02 -Muroya Subdivision January 12, 2007 Pa e4 Engineering: Engineering completeness items will follow under separate cover. Please contact Clyde Wickham with any questions regarding Engineering comments. Clyde can be reached by telephone at (760) 602-2742. ISSUES OF CONCERN Planning Department: 1. "Dwelling, Multiple-Family" is defined as a building, or portion thereof, designed for occupancy by three or more families living independently of each other, and containing three or more dwelling units (C.M.C. Section 21.04.135), while "Dwelling, One-Family" is defined as a detached building designed exclusively for occupancy by one family and containing one dwelling unit (C. M. C. Section 21.04 .125). The units proposed within this project do not meet the definition of "dwelling, multiple-family," and as such the City must review the project utilizing the Table "D" (C.M.C. Section 21.45.070) standards. Staffs review of the project against the Table "D" standards has revealed major project shortfalls and deficiencies. Please note that a Planned Development code update was recently recommended for approval by the City's Planning Commission. However, this code update has not yet been adopted by the City of Carlsbad City Council or the California Coastal Commission and therefore cannot be utilized at this time. As such, staff cannot support the project as currently proposed unless the project applicant substantially redesigns the project to meet the Small Lot Single Family and Two-Family Development Standards found in Table "D". Staff is available to further discuss this issue. The following is a list of project shortfalls and also some possible solutions to help achieve your development goals: · a. Planned Development-Table "D" requires a minimum lot size or exclusive use area of 5,000 square feet for each unit. Each unit must have the minimum 5,000 square foot exclusive use area. The Exclusive Use Area Summary listed on Sheet 2 of the Tentative Map identifies 13 units which clearly fall short of meeting the minimum 5,000 square foot area requirement. In addition, many of those units which are, identified by the applicant as meeting or exceeding the 5,000 square foot minimum area requirements also do not qualify as an exclusive use area based on the definition of exclusive. Staff can point to several examples in the project where driveway access for one unit or multiple units are crossing over another. This configuration does not provide for the necessary exclusive use area in order to meet the minimum development standard. b. The project is required to meet a minimum lot coverage percentage based on the Planned Development Table "D" requirements. As presently configured, many of the exclusive use areas do not meet the minimum 5,000 square feet area requirements and thus consistency with lot coverage cannot be ascertained as proposed. With a project redesign and re-submittal, please provide a lot coverage consistency matrix. c. The project is required to meet a minimum lot width requirement of 50 feet. The exclusive use area would need to meet this same requirement. A majority of the r". 0. GPA 06-09/ZC 06-08/LC~ 06-09/CT 06-27/CP 06-19/CDP 06-32/HDP 06-10/HMPP 07-02 -Muroya Subdivision January 12, 2007 Pa e 5 project does not appear to meet this minimum requirement. With a project redesign and re-submittal, please provide a lot width consistency matrix. d. There are opportunities to increase usable pad area and reduce retaining wall heights by better utilizing the minimum front yard setbacks. For example, the front yard setback for a garage along a private drive is 5 feet and the residence is 8 feet. Product type could be redesigned to better accommodate these setbacks and in turn reduce impacts on the site. The project could also utilize Private Drives as opposed to Private Streets to increase lot area and accommodate the proposed product type better. e. Units 11, 13, 32, and 33 are not meeting minimum front yard setback requirements for porches, residences and direct entry garages. Please revise. f. Provide a Planned Development Table ".D" side yard setback consistency matrix. g. Provide a Planned Development Table "D" rear yard setback consistency matrix. h. The 18' x 18' Recreational Space/Private Rear Yard is required to be located to the rear yard. For Units 21, 34 and 35, the private rear yard is oriented to the side of the unit and must be reconfigured to be located to the rear. Also, please plot the 18' x 18' recreational space to the rear of Unit 11. i. Please demonstrate project consistency with Planned Development Table "D" Garage Standards. It does not appear that the project is in compliance with the majority of the units exhibiting garage forward architectural design. j. All the motorcourt areas will need to be revised to include enhanced pavement treatments in addition to the pavement treatments at the driveway entrances. k. Planned Development Table "C" (C.M.C. 21.45.060) allows for a 24 ft. wide driveway with no parking permitted in the travel way. Staff suggests possibly reducing the 30 ft. wide Private Drive "B" in front of Units 1, 2 & 3 down to a 24 ft. width to provide an additional 6 ft. of developable area and allow for a reduction in retaining wall height along Black Rail Road. I. Planned Development Table "C" (C.M.C. 21.45.060) requires that all open parking areas shall be screened from adjacent residences and public rights-of- way by either a view-obscuring wall or landscaping. Please revise the site plan to comply where visitor parking spaces P-14 through P-15 are located. m. The Architectural Plans propose a Plan 1A and 1 B, Plan 2A, 28 and 2C, Plan 3A, 38 and 3C, and Plan 48 and 4C, resulting in 10 architectural combinations, however the Composite Site Plan only shows four floor plans. Please revise the plan to also show the specific architectural style. This may help to clarify Issue Item "n" below. n. City Council Policy 44, Architectural Guideline #5 requires that houses with both the same floor plan and elevation style shall not occur on adjacent lots. Units 2, 3, 5, 6, 13, 14, 18, 19, 25, 26, 28 and 29 all are the same units placed in pairs GPA 06-09/ZC 06-08/LC~ 06-09/CT 06-27/CP 06-19/CDP 0~2/HDP 06-10/HMPP 07-02 -Muroya Subdivision January 12, 2007 Pa e6 directly adjacent to each other. Furthermore, the same floor plan is being placed directly across from each other at many locations. o. With the project site being so constrained, it is suggested that the applicant explore the possibility of trying to meet the reduced second story requirements of Architectural Guideline #6 instead of the wide single-story product type that is being proposed. The proposed single-story unit requires such a large amount of space and is causing the majority of the site constraint problems. A reduced second story unit could free up a lot of additional space and in turn reduce the amount of grading and retaining walls. p. Graphically demonstrate in an exhibit for each Plan how you are complying with City Council Policy 44, Architectural Guideline #9. q. Revise Policy 44 Criteria Compliance Table, Architectural Guideline #10 Comment to reflect "street side" elevation as opposed to "rear" elevation. The sentence should be corrected to read as follows: Plan types 2 & 3 are plotted on a total of 24 lots within the development and meet the minimum number of four building planes on the FeaF street side elevation. r. Plans 3 and 4 are designed to meet the intent of Architectural Guideline #12, however, while the Plan 1 may be configured to have a side yard setback which averages greater then 8.5 feet, the general design of the Plan 1 does not meet the intent of this guideline in that it does not have the "sufficient offsets and cutouts" to qualify. s. The project needs to be designed better to comply with Policy 44 Architectural Guideline #16 pertaining to front entries. The projects current configuration does not meet the intent of this guideline. The majority of the Plan 4 home's front entries are concealed behind the garage and would require someone walking around the side of the garage to access the front of the home. The remaining Plan 4 homes (Units 21 and 24}, which do face the street are then impacted by a 2:1 slope or 5.5 ft. tall retaining wall. The Plan 3 homes as configured also requires walking around the side of the garage and then 33 feet down the side of the house to access the front door. The majority of the Plan 2 homes as configured are concealed between the front of the garage and the neighboring home. Please redesign to more consistent. t. While the project may utilize a combination of front and side-loaded garages to provide variety, the homes have not been designed to feature the residence as the prominent part of the structure in relation to the street. Council Policy 66, Principal #2 requires that a variety of garage configurations should be used to improve the street scene. This project, as configured clearly falls short of this goal and should be redesigned. 2. In general, staff is greatly concerned about the placement and number of retaining walls that are being proposed throughout the project in order to maximize unit yield. It is strongly advised that the number and heights of retaining walls be significantly reduced, or more preferably removed altogether. There are many design options available at the applicant's disposal that could be implemented to reduce or eliminate the need for walls. If other options cannot be positively explored, then staff strongly suggests that the GPA 06-09/ZC 06-08/LC~ 06-09/CT 06-27/CP 06-19/CDP 0~2/HDP 06-10/HMPP 07-02-Muroya Subdivision January 12, 2007 Pa e 7 applicant reduce the number of units, or redesign a new product type to fit the site. This is a topographically constrained site, which may call for topographically designed product types. Furthermore, the proposed grading/pad heights in the northwest and southeast must be more considerate of the adjacent pad heights on the surrounding properties. More specifically, staff would strongly encourage the applicant to redesign the area encompassing Units 35-37 in order to reduce the amount of fill. Staff is available to further discuss this issue. 3. The project is proposing development of natural slopes with over 40% slope gradients. Please update the slope analysis exhibit to demonstrate compliance with Section 21. 95.120(8) of the Carlsbad Municipal Code. 4. The project is proposing to impact 0.24 acres of the total 4.4 acres of dual criteria slopes. Please update the slope analysis exhibit to specifically identify impacts to the dual criteria slopes as they result directly from grading. 5. The 2:1 slope proposed along the west boundary of the project must be contour graded pursuant to Section 21.95.120(F)(1) of the Carlsbad Municipal Code. 6. Provide an additional slope profile detail to the Hillside Development Permit Constraints Map, which crosses through Units 6, 10, 14, and 18 and extends across both Black Rail Road and Nightshade Road. 7. Staff cannot support the double retaining walls being proposed to the rear of Units 9, 10, 11, 13, 14, 15, 35, 36 and 37 as their combined heights exceed the 6 foot maximum height limit allowed by code (C.M.C. Section 21.95.120(C)). Please revise the overall project and·grading to minimize or eliminate the use of all retaining walls. 8. Staff cannot support the retaining walls that are being proposed along Private Street "A", specifically running in front of Unit 24 and within the front yard setback area of Unit 23, as the retaining wall heights exceed the 42 inch maximum height limits allowed for structures within the front yard setback. Please revise the overall project and grading to minimize or eliminate the use of all retaining walls. 9. The intervening slope area between a retaining wall and the property line of an adjacent property must be a minimum of three feet in width in order to provide an adequate plantable area. This three foot width of plantable area cannot include the retaining wall. Please revise the Property Line -Side Yard Plantable Area Detail on Sheet 2 of the Tentative Map, along with all other plans as they apply directly to this requirement. 10. On Tentative Map Sheet 4, please provide a top and bottom elevation of the end portion of the retaining wall near Units 9 and 15. 11. Pursuant to Section 21.85.050 of the Carlsbad Municipal Code, the projects inclusionary housing responsibility would be 7 units as opposed to the 5.5 units discussed in your submittal letter dated December 5, 2006. The 7 units is based on the. applicant interest in providing inclusionary housing offsite through the purchase of affordable housing credits in an approved affordable housing project. The formula for calculating the project's inclusionary housing requirement is as follows: 37 Units+ 0,85 = 43.5 X 0.15 = 6.5 or 7 units (fractional units are required to be round up to the nearest whole number). GPA 06-09/ZC 06-08/LC$;06-09/CT 06-27/CP 06-19/CDP 06~/HDP 06-10/HMPP 07-02 -Muroya Subdivision January 12, 2007 Pa e 8 12. Revise the 60 foot wide fuel modification zones on all the plans to also show each of the three zones. As it relates to the rear yards of Units 22 and 23, it is strongly suggested that the fence line behind Units 22 and 23 be revised such that the exclusive use area is not encroaching into any of the three zones. 13. Please clarify by providing a detailed exhibit describing exactly what is being proposed at the entry of the subdivision specifically at Private Street "A" and Black Rail Road. It cannot be ascertained through the review of the plans if these are decorative entry walls or retaining walls. Either way, in addition to providing the detailed exhibit, the tentative map and other exhibits must also be updated to show the proposed heights of any walls or retaining walls should it be discovered that the entry feature is either of the two. 14. Revise the 8.5" X 11" copy of the General Plan Amendment & Zoning Change Map to also include the existing General Plan Land Use designation, Zone and Land Use information for the neighboring properties to the north located off of Corte Orchidia. 15. Include a detail plan view and sight line perspective from Black Rail Road of the proposed RV Storage area. It is not clear from the proposed plans how effective the screen being proposed will in fact screen the RV storage facility. Please not~ that Planned Development Table "C" standards (C.M.C. 21.45.060) prohibit the storage of recreational vehicles in any location that is visible to the public. 16. Identify and label on all plans as appropriate how much square footage is being allocated to RV storage. Engineering Department: Engineering comments to follow under separate cover. Please contact Clyde Wickham with any questions regarding Engineering comments. Clyde can be reached by telephone at (760) 602- 2742. Landscaping (PELA): The numbers below are referenced on the red line plans where appropriate for ease in locating the area of the comment concern. 1. The plans are very general and therefore a complete review could not be made. Additional comments may be provided once the plans are re-submitted with additional detail. · 2. Provide a shrub and groundcover planting legend for the concept which indicates where plantings are to be used. Coordinate the design and legend of the Concept Plan with the Fire Prevention Plan & Water Conservation Plan. At present the three plans function independently and do not coordinate. All three plans should interface showing the same plantings. 3. Hydroseed Mix "A" is shown in areas such as this that do not seem appropriate for this treatment, where a more manicured landscape is generally found. ..... j • GPA 06-09/ZC 06-08/LCQ 06-09/CT 06-27/CP 06-19/CDP 0~2/HDP 06-10/HMPP 07-02 -Muroya Subdivision January 12, 2007 Pa e9 4. The Hydroseed Mix "B" is shown in areas that are not appropriate, including front yards and parkways strips. 5. Clearly show all ROW lines, property lines and existing easements. 6. Show all planned bio-swales. 7. 50% of the shrubs (except on slopes 3:1 or steeper) must be a minimum 5 gallon size. Indicate this in the legend. Provide a count of shrubs by species or put a note in the legend. 8. Provide a separate full scale colored plan showing potable and recycled water use areas. This is required by the Water Department. 9. Provide a maintenance responsibility plan, clearly showing private homeowner/resident maintenance versus a common maintenance association. 10. Provide full landscaping in all areas except rear yards which are fenced. 11. Provide Carrotwoods as the street tree species along Black Rail Road. This will provide a repetition of this tree from the adjacent properties. 12. Show all existing trees including trees adjacent to Nightshade Road (Eucalyptus and Pines). Clearly indicate on the plans all trees to be retained and those to be removed. 13. Provide shrubs and groundcover in this area. 14. Provide a landscape screening separation between the parking and the perimeter fence. 15. Clearly show all slopes with a distinctive hatch and tie this to the slope note requirements on page 3. Use the hatch pattern selected only for slopes and provide a list of shrubs and groundcovers that will be used in this slope zone. Provide a different hatch pattern for slopes affected by Fire Protection Zone constraints. Show all trees on the plan. 16. Where are columnar shrubs used? Provide a symbol and show them on the plan. 17. Provide a blow up on the entry areas off of Black Rail Road. Provide enhanced planting including more trees and descriptions of the paving and walls to be used. 18. Add large canopy shade trees in the areas indicated with yellow highlighting. Where small trees are shown, select a larger species than the Pinus pineal Arbutus /Cercis now shown. 19. Add two Carrotwood street trees in this location. 20. The Fire Prevention Plan does not show Fire Zone #1 on the plan. Provide a different hatch for Zone 2 (manufactured) and Zone 2 (native). Zone 2 requires irrigation for both manufactured and native conditions. Provide a plant palette tied to each of the zones on the Fire Prevention Plan. This should be consistent with that which is shown on other sheets. .......... GPA 06-09/ZC 06-08/LCf'A'06-09/CT 06-27/CP 06-19/CDP 06~2/HDP 06-10/HMPP 07-02 -Muroya Subdivision January 12, 2007 Pa e 10 21. Return all redlines with the next submittal. Fire Department: 1. All dwelling units shall be provided with Automatic Fire Sprinklers. 2. All streets shall be recorded as Fire Lanes and subject to the restrictions and enforcements afforded to this designation. 3. On-street parking shall not be permitted on Private Streets "B" and "C" as the street width is to narrow to accommodate any on-street parking. The bulb at the end of Private Street "A" shall also be designated as a "No Parking Zone". Police Department: Please find enclosed as a separate document, comments from the City of Carlsbad Police Department dated December 21, 2006. ., ·~ ' .. Raker~ field 661.334.27:55 0 0 ENVIRONMENTALSERVICES • PLANNING • NATIJRALREsOURCESMANAGEMENT MEMORANDUM Date: To: From: Subject: December 11, 2006 Ms. April Tornillo, Taylor Woodrow Homes, Inc Jennifer M. Sanka, M.A., Staff Archaeologist Summary of Cultural and Paleontological Resource Findings for the Taylor Woodrow, Inc. Muroya Project in the City of Carlsbad, San Diego County, California At the request of Ms. April Tornillo, Michael Brandman Associates (MBA) has conducted a Phase I cultural and paleontological resource assessment at the proposed Project Area located in the City of Carlsbad, San Diego County, California. The detailed Phase I Cultural Resources Assessment will be available in the forthcoming document entitled: Phase I Cultural Resources Assessment and Paleontological Records Review Muroya Project City of Carlsbad, San Diego County, California (MBA, 2006). The following information has been adapted from this Phase I report. Project Location and Description Totaling approximately 20 acres, the Muroya Project Area can be found on the Encinitas, California, United States Geological Survey (USGS) 7.5-minute topographic quadrangle map, in the northern half of section 27 ofTownship 12 South, Range 4 West. Specifically, the Project Area is located west of Black Rail Road, north of Aviara Parkway and east of Towhee Lane. The proposed use of the Project Area is for future residential development. Summary of Cultural Resource Findings On November 28, 2006, MBA Consulting Archaeologist Jonathan Wright conducted a records search at the South Coastal Information Center (SCI C), which is located at San Diego State University. According SCIC files, approximately 75 previously known cultural resources are recorded within the 0.75 mile search radius. One ofthese cultural resources is located in the southern portion of the plant nursery, which presently occupies the northern and eastern portions of the overall Project Area. ~'\­Sv..~~ \-\.d_ u.:> I i V\ \ ~,"' \ c:::.....~~\..k~ p:..c.~Q.. DC- 'Dc2-c.., l ~ '2,v0fo I MBA Project Archaeologist Jennifer M. Sanka surveyed the Project Area on December 3 and 5, 2006. As a result of the pedestrian survey, an additional isolated cultural resource was identified. ~"'-:ck ~ ? Fre~no 559.497.0310 Irvine 71 cf.508.+ lUO WW\v.brandman.com Palm Springs 760.322.88-f? Sacramento San Bernardino San Ramon 916.383.09cf4 909.884.2255 925.830.2733 mba@brandman.com Santa Cruz 831.262.1731 Ms. April Tornillo December 11, 2006 Page2 Summary of Paleontological Resource Findings The paleontological review, conducted by Margaret M. Hart, Lab Manager of the San Diego Natural History Museum (SDNHM), showed that the sedimentary rocks mapped in the vicinity of the Project Area are middle Pleistocene Terrace Deposits (approximately 0.5 to 1 million years old) which correlate with the Lindavista Formation, as well as middle Eocene Santiago Formation sediments ( 45 to 49 million years old). Excavation within the Project Area would likely impact deposits of the Lindavista Formation, the Santiago Formation and Torrey Sandstone. While deposits of the Lindavista Formation and Torrey Sandstone have moderate paleontological sensitivity, sediments belonging to the Santiago Formation are assigned high sensitivity.*'Any fossils recovered from these sediments have high potential to be considered scientifically significant. H ... \e.o. ~uecL.. M,'~a.t\ ~ The review additionally revealed that there are 32 known paleontologic resource localities within the 1 mile search radius. Three of these localities are situated directly south of the proposed Project Area. Cultural Resource Recommendations Due to the presence ofthe numerous cultural resources within the 0.75 mile search radius, the known resource within the Project Area boundaries and the previously undocumented isolated cultural resource fmding during the pedestrian survey, MBA finds that the Project Area has a high probability for retaining intact, subsurface cultural resources. Therefor#,"MBA recommends that cultural resource monitonng take place during all ground disturbing activities associated with the proposed development. This monitoring program should be developed prior to any grading within the Project Area. MBA also recommends that Native American monitoring take place if required or recommended by the City of Carlsbad. Paleontological Resource Recommendations Due to the high sensitivity designation of sediments from the Santiago Formation and the presence of the numerous paleontological resource localities within the 1 mile search radius, many of which were recovered from sediments similar to those present within the Project Area, MBA finds that the Project Area has a high probability for retaining significant, nonrenewable paleontological resources. Therefore, MBA recommends that paleontological resource monitoring take place during all ground disturbing activities associated with the proposed development. This monitoring program should be developed prior to any grading within the Project Area and should be consistent with the provisions of CEQA. JMS:ji H:\Ciient (PN-JN)\1617\16170007\Cultural\16170007_Memo to Ms. Tornillo.doc G,..~\~. t-1;~\~C...~ t1~. C .... \t-.xc..\ ev_. M•'-\-~c..~o,f\ M~· -. December 5, 2006 Jason Goff City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 ,Ok Henthorn & AssociatD 5365 Avenida Encinas, Suite A Carlsbad, California 92008 (760) 438-4090 Fax (760) 438-0981 Subject: Muroya Property-Tentative Map and Condominium Permit Submittal Package Dear Mr. Goff: The enclosed materials are submitted on behalf of Taylor Woodrow Homes, Inc., for a proposed residential development of thirty-seven (3 7) detached condominium units located within Local Facilities Management Zone 20 on the west side of Black Rail Road (APN 215-040- 03). The enclosed applications for review include a tentative tract map, condominium permit, coastal development permit, hillside development permit, general plan amendment, zone change and local coastal program amendment. The proposed property has gone through the preliminary review process (PRE 06-07). The following letter gives a detailed project description and addresses the comments received in the City's letter dated March 13, 2006. The approximate twenty (20) acre site is currently being used as a palm tree nursery and a single-family residence for the Muroya family. The site has a current General Plan designation of RLM (Residential Low-Medium density, 0-4 du/ac) and a zoning classification of L-C (Limited Control). These designations are proposed to be modified with the project and will be discussed in further detail below. The site is surrounded by existing residential development on all four sides. The developments to the west and south of the subject property are within the Aviara Master Plcm. The development to the west is a detached single-family neighborhood having lot sizes that range in size from 7,500 to 10,000 square feet. The development to the south is a condominium development located on both sides of Black Rail Road. The residential development to the north contains thirty-two (32) existing detached single family homes on minimum 10,000 square foot lots. The residential developments to the east across Black Rail Road are in different stages of the development process. Some units are constructed and currently occupied, another property is currently graded and the southern most property has an active application in the City for residential development. All of the properties to the east are small-lot developments with minimum lot sizes of 5,000 square feet. 0 0 As mentioned above, the subject property includes an active palm tree nursery and an existing single family residence located in the southeastern portion of the property that is occupied by the Muroya family. The nursery operation includes shade houses, equipment sheds and associated access roads. A 150-foot wide easement for SDG&E transmission lines extends through the central portion of the property. The remaining property is undeveloped and covered with native vegetation. Topographically, the eastern and northern portions of the site, where the existing residence and nursery are located, generally consist of a relatively level to gently sloping mesa. The property in these areas has a total elevation drop of approximately twenty (20) feet from Black Rail Road to the west. The western and southern portions of the property consists of moderately to steeply inclined natural and fill slopes extending from the SDG&E easement south and west into a large canyon. The elevation differential in these areas is approximately eighty (80) feet from east to west. All utilities necessary to serve the proposed project are located within Black Rail Road and Nightshade Road. As shown on the enclosed tentative map, the applicant is proposing thirty-seven (3 7) detached condominium units on a five (5) lot subdivision. As mentioned above, the property is designated with a RLM land use designation that has a Growth Management Control Point of 3.2 dwelling units per acre. The enclosed constraints analysis used the current control point for calculating the maximum number of units allowed on the site, which is thirty-eight (38) dwelling units (11.81 net acres x 3.2 du/ac = 37.8 units). With the existingMuroya residence that is proposed to remain, the total number of units proposed on the property is thirty-eight (38) consistent with the maximum number allowed. A General Plan amendment is proposed as part of the project to reflect the clustering of the development on the northern and eastern portions of the site and to designate the conserved open space consistent with the preservation standards within the City of Carlsbad's Habitat Management Plan (HMP). By designating the proposed open space with an Open Space land use designation along with the clustering of the units in the northern and eastern portions of the site, the density proposed for the development area results in a higher density than that allowed by the RLM land use designation. As a result, the proposed land use designation that is consistent with the density of the development area is Residential Medium (RM -4-8 dwelling units per acre) with an implementing zoning classification of Residential Density-Multiple (RO- M). The proposed open space for the project is proposed with a new General Plan land use designation of Open Space (OS) with an associated zoning classification of Open Space (0-S). Please refer to the enclosed 'General Plan Amendment and Zone Change Exhibit' for details. The subject site is heavily constrained with the large SDG&E easement that bisects the property, the large canyon that contains native vegetation and the sloping topography from east to west. Along with the physical constraints oi1 the property, it is also subject to the preservation standards of the HMP and, as a property that is located within the Coastal Zone, is subject to additional HMP conservation standards. These standards, as applicable to the subject property, 0 0 include avoiding impacts to southern maritime chaparral and narrow endemic plant species, minimizing impacts to coastal sage scrub, providing continuous habitat connectivity within the zone but allowing reasonable development on the lower habitat quality areas. The specific coastal standards for the property include the cluster of the development within the existing disturbed areas and that a maximum of ten percent (10%) impact may occur to coastal sage scrub and southern maritime chaparral. The HMP also identifies the necessity of providing buffers between development and any proposed preserve areas. For the proposed property a buffer of twenty (20) feet is required between the development and the upland native vegetation. Given the above constraints the applicant and their consultant team carefully planned and designed the proposed clustered condominium project to comply with the standards found within the City's HMP as well as the applicable zoning standards found within the Carlsbad Municipal Code. Since the proposal is a condominium project clustered to avoid impacts to the native habitat as required by the HMP, the site was designed to be consistent with the multi- family standards of the Planned Development ordinance. The density of the proposal and the auto courtyard layout of the site plan are more consistent with a multi-family development than a traditional single-family subdivision. The detached nature of the condominiums is for the compatibility of the project with the existing residential neighborhoods adjacent to the subject property. The majority of the existing surrounding neighborhoods were not restricted with the same HMP preservation standards that have been imposed on this property. It is also understood that the Planned Development ordinance is being amended and the project has been designed to be consistent with the new standards for future consistency. As shown on the enclosed plan sets and mentioned above, the design of the project is for thirty-seven (3 7) detached condominiums clustered in the northern and eastern portions of the subject property. The majority of the proposed development is located north of the SDG&E easement with three units proposed south of the easement adjacent to the existing Muroya residence. The proposal is designed with two points of access from Black Rail Road. The main point of access for the project will be Private Street 'A' that is proposed as a cul-de-sac and aligns with the existing intersection of Songbird Avenue. The private street is intersected by two main private driveways, Private Drive 'B' & 'C'. Private Drive 'C' crosses the SDG&E easement and connects to Black Rail Road aligning with the existing intersection of Ocean Crest Avenue providing the secondary point of access for the project. The private driveways are proposed to include enhanced paving where they intersect the private street and Black Rail Road. The auto courtyards are proposed along both the private street and private driveways to access each of the unit's two-car garages. These courtyards will be constructed with concrete as required by the Planned Development Ordinance. Parking for the project is proposed with two-car garages for each unit and visitor parking provided on-street on Private Street 'A' and within parking bays along Private Drives 'B' & 'C'. There is total of twelve (12) visitor parking spaces that are required for the project. As proposed, 0 0 there are seventeen (17) spaces provided throughout the development within walking distance of each unit. A common recreational vehicle storage area is also proposed for the project that will be available to all residents. The location of the storage area is within the SDG&E easement and was conceptually approved by SDG&E pursuant to the enclosed letter dated September 5, 2006. The proposal includes four unit types ranging in size from approximately 2,070 to 2,800 square feet and will utilize three separate architectural styles. Plan type 1 is proposed as a single story unit to comply with the Policy 44 requirement for providing single-story units. The remaining plan types are proposed as two-story units. The architectural styles proposed with the development are Adobe Ranch, Andalusian and Santa Barbara. These styles were speci8lly selected by the applicant and architect to create a cohesive village atmosphere. The Adobe Ranch and Andalusian styles include elements of rustic ranch stylized architecture with such details that include wood kickers and other wood detailing such as shutters and Juliet balconies. The Santa Barbara style is a more refined style from the previous two styles with arches, iron detailing and finished stucco elements such as pot shelves and trim around balconies. To further create a sense of diversity throughout the community, professionally designed color schemes have been created. There are a total of six (6) color schemes for this neighborhood as shown on the enclosed color and material boards. Common recreational space as required by the Planned Development Ordinance is proposed in two areas for the project. The main recreational space for the project is located along Private Drive 'C' and includes a pool and spa facility adjacent to the northern boundary of the SDG&E easement. The area does expand beneath the SDG&E easement by including a passive area with trails, a large grass area and overlook areas for the enjoyment of both the natural open space and views to the west. The second recreational space is located in the western portion of the site at the end of Private Street 'A' and includes a tot lot area with various age play equipment. Per the Planned Development Ordinance the project is required to provide 7,400 square feet of common recreational space. As proposed the project includes a total of 10,290 square feet excluding the area beneath the SDG&E easement well exceeding the minimum required. The City's Inclusionary Housing Ordinance requires that a minimum of 15% of all approved units in any qualified residential subdivision be made affordable to lower income households. The inclusionary housing requirement for this project is calculated to be 5.5 dwelling units. The applicant is requesting to purchase 5.5 affordable housing credits in an approved affordable housing project to satisfy the project's affordable housing requirements. In response to the City of Carlsbad's comments to the preliminary application and subsequent meetings with staff, the project applicant, Taylor Woodrow Homes, Inc., did conduct a community outreach meeting on November 14'h of this year with the surrounding owners. The meeting was to inform the existing neighborhood of the project and elicit their input and • 0 0 concerns. The main concern expressed during the meeting was related to the existing views to the west. In the preparation of the enclosed plans, the applicant and their consultants made the utmost effort to address the concerns that were raised by ensuring that single-story elements of the architecture were situated along the northern boundary to provide some view corridors to the west and lowering the proposed pad heights as much as possible while maintaining a balanced grading operation. Once the City releases the comments to this submittal and they have been addressed by the consultant team, the applicant will follow up with the existing residents to inform them of the status of the application and the necessary modifications to the plan so that a positive relationship with the surrounding owners is maintained. Enclosed with the submittal package is a copy of the sign-in sheet that was used for the November neighborhood meeting. We have included 5 sets of the tentative map, conceptual landscape plans and architecture plans for your review along with all the supporting documentation. This documentation includes all the required executed applications, updated preliminary title report, project description, location map, hydrology study, water quality technical report, compliance tables for City Council Policies 44 and 66, preliminary soils investigation, biological report and environmental impact assessment form. If you have any questions or need any additional information, please feel free to call me at (760) 438-4090 extension 104 or e-mail me at b1'nnc~r(i't jhcnth~ml.Cl2!J1· Sincerely, encl. Tentative Map Submittal Package cc: April Tornillo, Taylor Woodrow Homes, Inc Marybeth Murray, Hunsaker & Associates Roy Capitan, Robert Hidey Architects Christopher Gustard, GMP, Inc. file JHA/BDBffWH -Muroya • Taylor Woodrow November 1, 2006 City of Carlsbad, Planning Department Attn: Jason Goff 1635 Faraday Avenue Carlsbad, CA 92008-7314 PROJECT: Muroya Property APN 215-040-03 Dear Mr. Goff: y· "' .!iC ut:~"ltd~E!t\ L1!y l.t Calls~aa I Taylor Woodrow Homes, Inc. South Division-Southern California 16745 W. Bernardo Dr. Suite 140 San Diego, CA 92127 Tel 858-943-5100 Fax 858-943-5151 taylorwoodrow.com I would like to take this opportunity to invite you to a meeting we have planned with the adjacent homeowners on November 141h at 6:30pm. Attached you will find information related to this neighborhood meeting. Taylor Woodrow Homes is very pleased and excited about the Muroya development and we have prepared a conceptual site plan and architectural streetscenes to help give the adjacent residents an idea about what the development will look like. If you have any questions regarding the meeting or the Muroya property development, please contact me at 858-943-5109. Sincerely, April Tornillo c ~ Taylor Woodrow November 1, 2006 Dear Resident, 0 Taylor Woodrow Homes, Inc. South Division-Southern California 16745 W. Bernardo Dr. Suite 140 San Diego, CA 92127 Tel 858-943-51 00 Fax 858-943-5151 taylorwoodrow.com Taylor Woodrow Homes invites you to a meeting presentation on our proposed single family detached residential development and afterwards a time for questions and answers will be provided. The meeting will be on Tuesday, November 141h located at the Olympic Resort Hotel and Spa in the Savannah room starting at 6:30pm. Taylor Woodrow Homes is pleased to inform you that we are proposing 37 single family residences. We are currently preparing an application to submit to the City of Carlsbad for the 6600 block of Black Rail Road, Carlsbad CA. The homes will be located on a portion of the property that is currently being used as a nursery for palms and other trees. A large portion of the site will remain as hill type terrain covered with native vegetation and left undisturbed as dedicated open space. The homes are designed one-story and two-story diversified with single story elements integrating nicely with the surrounding neighborhood. We are looking forward to meeting you and discussing any questions or concerns you have. Refreshments will be provided. If you can't attend the meeting, or if you have any questions before then, please feel free to contact April Tornillo at Taylor Woodrow Homes at (858) 943-5109. Please join us on: TUESDAY, NOVEMBER 14, 2006 6:30PM -7:30PM AT OLYMPIC RESORT HOTEL AND SPA SAVANNAH ROOM 6111 EL CAMINO REAL CARLSBAD, CA 92011 c ) A~ Sempra Energy utility''' September 5, 2006 April Tornillo Taylor Woodrow Homes, Inc. 16745 W. Bernardo Drive, Suite 140 San Diego. CA 92127 RECEIVED SEP -6 2006 BY: __ Subject Project: Muroya Subdivison-A.P.N. 215-040-03 Dear Ms. Tornillo: San Diego Gas & Electric 8335 Century Park Court San Diego, CA 92123 Please note, this is not a "Permission to Grade & Construct Improvements" letter for the above~mentioned project, but rather a conceptual approval of the Planning Design Map submitted to San Diego Gas & Electric (SDG&E) date stamped August 9, 2006. SDG&E will review and comment on the proposed grading and improvements to be constmcted within and adjacent to SDG&E's 150' Electric & Gas Transmission easement located on said property. The proposed private road, RV parking, a "passive" park, drainage, and other associated improvements are allowed within the easement area. We will continue to review the developing plans for compliance with our design requirements within the easement area and when our requirements are satisfied, SDG&E will issue a "Permission to Grade-& Construct Improvements" letter for this project. Should you have any questions, please call me at the numbers listed below. Sincerely, Land Management Representative Phone (858) 654-1201 Fax (858) 654-1263