HomeMy WebLinkAbout2013-06-19; Planning Commission; ; CT 12-01|PUD 12-08|CDP 12-15 - MILES PACIFIC SUBDIVISION
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 2
III. PROJECT DESCRIPTION AND BACKGROUND
The Miles Pacific Subdivision is a 5.4 acre project site consisting of three separate parcels
generally located on the west side of Pio Pico Drive near the intersection of Pio Pico Drive and
Las Flores Drive. The site is surrounded by existing single family homes on the north, south and east sides of the property, and abuts the I-5 Freeway on the west side of the property. The site is improved with a single-family house that is located at the northeastern most portion of the
property fronting Pio Pico Drive, while the remaining portion of the site is predominately used
for greenhouse agricultural production. Historical photos and other documents show that a
majority of the property has been used for agriculture purposes for over 70 years. Topographically, the site is relatively flat to very gently sloping in a southwesterly direction. On-site elevations range from approximately 82 to 110 feet above mean sea level. Access to the
site will be provided by a new private street located off of Pio Pico Drive. The previously
graded and disturbed site is devoid of any significant or sensitive vegetation.
The project site and surrounding properties have an existing General Plan Land Use Designation of Residential Low-Medium Density (RLM), which allows low to medium density residential
development (0 to 4 du/ac) with a Growth Management Control Point (GMCP) of 3.2 du/ac. The
property and surrounding properties are zoned R-1 (One Family Residential). The proposed
project includes a Tentative Tract Map, Planned Development Permit, and Coastal Development Permit to allow for the demolition of the existing structures and to subdivide and grade the property into 17 single-family lots ranging from 7,509 square feet to 13,626 square feet in size.
Three other non-residential lots will be created; one lot for the private street system, and two bio-
retention lots. The Planned Development Permit is only required to enable the development of a
private internal street (street “A”) and a private drive aisle (street “B”). Project grading requires 9,910 cubic yards of cut and 9,910 cubic yards of fill which will result
in a balanced grading operation. As previously stated, the project site has been historically used
for agriculture purposes for over 70 years. As part of the project’s environmental review, a
limited Phase II site characterization and agricultural residue survey was performed on the project site. Based upon the limited scope of work completed, Toxaphene was detected at the project site well above the maximum limits developed by the California Environmental
Protection Agency (CEPA) that may possibly represent a risk to human health and ground water
if not mitigated. Therefore, the appropriate environmental mitigation measures were
incorporated into the conditions of approval for this project in order to mitigate identified environmental impacts to a level of insignificance. The mitigation measures are listed within the Mitigated Negative Declaration and Mitigation Monitoring and Reporting Program.
IV. ANALYSIS
The project is subject to the following regulations:
A. Residential Low-Medium Density (RLM) General Plan Land Use designation;
B. One Family Residential (R-1) Zone, and Planned Development regulations (Chapters
21.10 and 21.45 of the Carlsbad Municipal Code);
C. Mello II Segment of the Local Coastal Program (Chapter 21.201 of the CMC) and the Coastal Resource Protection Overlay Zone (Chapter 21.203 of the CMC);
D. Subdivision Ordinance (Title 20 of the Carlsbad Municipal Code);
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 3
E. Inclusionary Housing Ordinance (Chapter 21.85 of the CMC); and F. Growth Management Ordinance (Chapter 21.90 of the CMC) and Zone 1 Local
Facilities Management Plan.
The recommendation for approval of this project was developed by analyzing the project’s
consistency with the applicable regulations and policies. The project’s compliance with each of
the above regulations is discussed in detail in the sections below.
A. General Plan Residential Low Medium Density (RLM) Land Use Designation The General Plan Land Use designation for the property is Residential Low-Medium (RLM) density. The RLM Land Use designation allows for the development of single family residential
units within a density range of 0 – 4 dwelling units per acre (du/ac) and at a Growth Management
Control Point (GMCP) of 3.2 du/ac. At the RLM GMCP, 17.28 dwelling units (17 when
rounded down) would be permitted on this site based on 5.40 net developable acres. The
project’s proposed density of 3.14 du/ac is slightly below the Growth Management Control Point density (3.2 du/ac) used for the purposes of calculating the City’s compliance with Government
Code Section 65863. However, consistent with Program 3.2 of the City’s certified Housing
Element, all of the dwelling units, which were anticipated toward achieving the City’s share of
the regional housing needs that are not utilized by developers in approved projects, will be
deposited in the City’s Excess Dwelling Unit Bank. This project will deposit 0.28 dwelling unit into the Excess Dwelling Unit Bank and these fractional excess dwelling units are then available
for allocation to other projects. Accordingly, there is no net loss of residential unit capacity and
there are adequate properties identified in the Housing Element allowing residential development
with a unit capacity, including second dwelling units, adequate to satisfy the City’s share of the
regional housing need.
The project complies with the Elements of the General Plan as outlined in Table A below:
TABLE A – GENERAL PLAN COMPLIANCE
ELEMENT
USE, CLASSIFICATION, GOAL, OBJECTIVE OR PROGRAM
PROPOSED USES & IMPROVEMENTS COMPLIANCE
Land Use Site is designated for
Residential Low-Medium density, (RLM – 0-4 du/ac)
with a GMCP of 3.2 du/ac.
17.28 dwellings units could be
constructed on the site at the
GMCP (5.40 acres x 3.2 du/ac).
17 Single-family units at a
density at 3.14 dwelling units per acre is within the
RLM density range of 0-4
du/ac. 0.28 dwelling unit
will be deposited into the
City’s Excess Dwelling Unit Bank.
Yes
Housing Provision of affordable
housing.
The project is conditioned
to enter into an affordable
housing agreement to provide three (3) Second
Dwelling Units that will be
located on lots 2, 5 and 11.
Yes
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 4
TABLE A – GENERAL PLAN COMPLIANCE
ELEMENT
USE, CLASSIFICATION,
GOAL, OBJECTIVE OR
PROGRAM
PROPOSED USES &
IMPROVEMENTS COMPLIANCE
Public Safety Reduce fire hazards to an
acceptable level
The project will install new
fire hydrant(s) consistent
with Public Safety Requirements
Yes
Open Space
&
Conservation
Minimize the environmental
impacts to sensitive resources
within the City.
Utilize Best Management
Practices for control of storm
water and to protect water quality.
The project will not have
any environmental impacts
to the previously graded site
that is void of sensitive habitat.
The project is conditioned
to conform to all NPDES
requirements and has been designed to include Low
Impact Design (LID)
elements.
Yes
Yes
Noise Comply with the residential exterior noise standard of 60
dB(A) CNEL and interior
noise standard of 45 dB(A)
CNEL.
A project site specific noise study for the Miles Pacific
Subdivision identified that
several lots will exceed the
exterior noise standard of 60 dB(A) and interior noise standard of 45 dB(A)
CNEL. For this reason, the
project site has been
designed with the installation of two foot tall berms and six foot tall
masonry sound walls to
reduce the noise levels,
which even with the noise wall and berm still exceed the residential exterior noise
standard of 60 dB(A)
CNEL, and special
architecture treatments (i.e.
specialized doors and windows) for the future
homes will be required to
mitigate noise levels which
are over the residential
interior noise standard of 45 dB(A) CNEL.
Yes
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 5
TABLE A – GENERAL PLAN COMPLIANCE – CONTINUED
ELEMENT
USE, CLASSIFICATION,
GOAL, OBJECTIVE OR
PROGRAM
PROPOSED USES &
IMPROVEMENTS COMPLIANCE
Noise
(Continued)
Furthermore, the project has
been conditioned for the
applicant to submit a supplemental interior acoustical analysis from the
acoustical consultant stating
that the architectural plans
for the future homes have
been designed in compliance with the
recommendations stated in
the acoustical report to
reduce interior noise
standards to a level of 45 dB(A)CNEL or below.
Since it is impractical to
design the project to comply
with the exterior noise
standard of 60 dB(A) CNEL without the installation of a
14 foot tall perimeter sound
wall (per the acoustical
study), the project has been
conditioned to notify all potential purchasers in
writing along with a deed
disclosure that the property
they are purchasing does not
meet Carlsbad exterior noise standards for residential
property.
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 6
TABLE A – GENERAL PLAN COMPLIANCE – CONTINUED
ELEMENT
USE, CLASSIFICATION,
GOAL, OBJECTIVE OR
PROGRAM
PROPOSED USES &
IMPROVEMENTS COMPLIANCE
Noise
(Continued)
The project site is also
located within the Interstate
5 North Coast Corridor widening project. As part of CalTrans future Interstate
5 North Coast Corridor
widening project, a 10 foot
high sound wall is
tentatively proposed along the project’s freeway
frontage that will help
reduce noise impacts from
Interstate 5. The project
applicant has been conditioned to submit to the
City Engineer written
approval from Caltrans
demonstrating that the
proposed improvements for the project are not in
conflict with the proposed
10 foot high sound wall.
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 7
TABLE A – GENERAL PLAN COMPLIANCE – CONTINUED
ELEMENT
USE, CLASSIFICATION,
GOAL, OBJECTIVE OR
PROGRAM
PROPOSED USES &
IMPROVEMENTS COMPLIANCE
Circulation Construct roadway
improvements needed to serve
proposed development.
The project will take access
off of Pio Pico Drive and
will be required to enter into a Neighborhood Improvement Agreement
(NIA)* because Pio Pico
Drive is designated as an
Alternative Design Street.
The project provides adequate circulation
infrastructure to serve the
projected population; and
provide a circulation system
that promotes safety and livability of residential
neighborhoods while
maintaining adequate
emergency access for
service providers and prompt evacuation
capabilities for residents in
that, primary local access to
the site will be provided via
private Street “A” and private drive aisle “B”. The
circulation system has been
designed in conformance
with Land Development
Engineering Division and Fire Department design
standards. The proposed
circulation system is
designed to provide access
to each of the proposed lots and dwelling units and
complies with all applicable
City design standards.
Yes
*NIA - A Neighborhood Improvement Agreement ensures that the property owner retains financial responsibility for constructing potential future street improvements.
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 8
B. R-1 One-Family Residential Zone (Chapter 21.10 of the CMC)/Planned Development Ordinance (Chapter 21.45 of the CMC)
The proposed project is required to comply with all applicable use and development standards of
the Carlsbad Municipal Code (CMC) including the R-1 Zone (CMC Chapter 21.10) and the private street and private drive aisle are subject to compliance with the private street and private drive aisle standards of the Planned Development Ordinance (CMC Chapter 21.45).
As summarized in Table B below, the project meets or exceeds the requirements of the R-1 Zone
and Planned Development regulations. TABLE B: R-1 ZONE AND PLANNED DEVELOPMENT ORDINANCE COMPLIANCE
Applicable R-1 Zoning Development Standards
Standard Requirement Proposed Comply
Minimum
lot size 7,500 square feet 7,509 SF to 13,626 SF Yes
Minimum
Lot width 60 feet 60 feet to 138 feet Yes
Applicable Planned Development Standards
Standard Requirement Proposed Comply
Private Street width (Street “A”)
56 feet minimum right-of-way width
34 feet minimum curb-
to-curb width
5 feet minimum sidewalk width
5.5 feet minimum
parkway width including curb
58 feet
36 feet
5 feet
5.5 feet
Yes
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 9
TABLE B: R-1 ZONE AND PLANNED DEVELOPMENT ORDINANCE COMPLIANCE CONTINUED
Applicable Planned Development Standards Continued
Standard Requirement Proposed Comply
Private
Drive-aisle
(Street “B”)
20 feet minimum of
right-of-way width and
enhanced with decorative pavement
No parking shall be
permitted within the
minimum required
width of a drive-aisle
A minimum 24-foot
vehicle back-
up/maneuvering area
shall be provided in front of the garages
Parkways and/or
sidewalks may be
required
No more than 24 dwelling units shall be
located along a single-
entry drive-aisle
34 feet and enhanced
with decorative pavement
No parking is proposed
within the drive-aisle
24-foot vehicle backup is
provided
A sidewalk is provided
on the western side of the
drive-aisle and a landscaped parkway is
provided on the eastern
side of the drive-aisle
Only 4 dwellings units are located on the drive-
aisle
Yes
C. Coastal Development Regulations for the Mello II Segment of the Local Coastal
Program (CMC Chapter 21.201) and the Coastal Resource Protection Overlay Zone
(CMC Chapter 21.203)
The project site is located within the Mello II Segment of the Local Coastal Program (LCP)
which contains land use polices for development and conservation of coastal land and water
areas within the Mello II segment boundaries. However, the project is not located within the
appeals jurisdiction area of the California Coastal Commission. 1. Mello II LCP Segment
The LCP Land Use Plan designates the subject site for Residential Low-Medium (RLM) density
development which allows a density of 0–4 du/ac. The project’s proposed density (3.14 du/acre) is consistent with the LCP RLM Land Use Designation as previously discussed in Section A of this report. The proposed 17 lot single family subdivision is consistent with the land use type
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 10
and density regulations for the site and is in compliance with the applicable Mello II LCP policies.
The project site has been used for agriculture purposes for over 70 years. However, the site is
not designated on Map X as a coastal agricultural resource and is not subject to the coastal agricultural preservation policies of the LCP. No sensitive habitat resources are located on the disturbed project site. The proposed subdivision is not located in an area of known geologic
instability or flood hazard. The proposed graded 17 residential lots will not obstruct views of the
coastline as seen from public lands or the public right-of-way, nor otherwise damage the visual
beauty of the coastal zone. No public opportunities for coastal shoreline access are available from the subject site. The residentially designated site is not suited for water-oriented recreation activities.
2. Conformance with public access and recreation policies of Chapter 3 of the Coastal Act
The property is located 1/4 mile from Buena Vista Lagoon and one mile from the Pacific Ocean; therefore, the project will not interfere with the public’s right to physical access to the sea, or
water oriented recreational activities.
3. Coastal Resource Protection Overlay Zone The project is consistent with the provisions of the Coastal Resource Protection Overlay Zone
(CMC Chapter 21.203 of the Zoning Ordinance) in that the project will adhere to the City's
Master Drainage Plan, Grading Ordinance, Storm Water Ordinance, Standard Urban Storm
Water Mitigation Plan (SUSMP) and Jurisdictional Urban Runoff Management Program (JURMP) to avoid increased urban run-off, pollutants and soil erosion. No development is proposed in areas of steep slopes (≥ 25% gradient) and no native vegetation is located on the
development area of the subject property. In addition, the site is not located in an area prone to
landslides, or susceptible to accelerated erosion, floods or liquefaction.
D. Subdivision Ordinance
The project includes seventeen (17) single family residential lots and is therefore subject to the
regulations of Chapter 20.16 of the Subdivision Ordinance. These subdivision regulations
require the project to include required street dedications and improvements (streets, sewer, water, and drainage) to serve the proposed subdivision.
The Land Development Engineering Division has reviewed the proposed Tentative Tract Map
and has concluded that the subdivision, as conditioned, complies with all the applicable
requirements of the Subdivision Map Act and the City’s Subdivision Ordinance. The project
will take access off of Pio Pico Drive and will be required to enter into a Neighborhood Improvement Agreement (NIA), because Pio Pico Drive is designated as an Alternative Design
Street. The developer will be required to install street and utility improvement for proposed
private Street “A” and private drive aisle “B”, including but not limited to curbs, gutters,
parkways, sidewalks, sewer and drainage facilities, fire hydrants, and street lights. General
utility and access easements will be dedicated to allow for the construction of project drainage, sewer, and water facilities on the final map.
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 11
No standards variances are needed to approve the project. Given the above, the proposed subdivision would provide all necessary facilities and improvements without producing land
conflicts; therefore, the project is consistent with the Subdivision Ordinance.
E. Inclusionary Housing Ordinance The proposed project involves the creation of seventeen residential units through a subdivision
and, therefore, must provide affordable housing to lower-income households as specified in the
Inclusionary Housing Ordinance (Chapter 21.85 of the Zoning Ordinance). For residential
development of seven or more units, not less than fifteen percent of the total units approved shall be constructed and restricted both as to occupancy and affordability to lower-income households. This 17 unit project is therefore responsible for providing three inclusionary units. Whenever
reasonably possible, inclusionary units should be built on the residential development project
site. The developer is proposing and the Housing Policy Team is recommending support of the
construction of three Second Dwelling Units to satisfy their inclusionary housing obligations. Therefore, the applicant has been conditioned to satisfy the inclusionary housing requirement for lower-income households by entering into an Affordable Housing Agreement to construct three
(3) Second Dwelling Units, subject to City Council approval. By entering into the agreement
prior to final map recordation the Miles Pacific Subdivision is providing its fair share of housing
affordable to lower income households and, therefore, is consistent with the Inclusionary Housing Ordinance.
F. Growth Management
The proposed project is located within Local Facilities Management Zone 1 in the northwest quadrant of the City. The impacts on public facilities created by the project, and its compliance with the adopted performance standards, are summarized in Table C below.
TABLE C - GROWTH MANAGEMENT COMPLIANCE
STANDARD IMPACTS COMPLIANCE
City Administration 59.10 sq. ft. Yes
Library 31.52 sq. ft. Yes
Waste Water Treatment 17 EDU Yes
Parks .11 acre Yes
Drainage 11.46 CFS Yes
Circulation 170 ADT Yes
Fire Station No. 1 Yes
Open Space 0 acres N/A
Schools Carlsbad Unified School District
E=5.78/M=2.01/HS =1.75)
Yes
Sewer Collection System 17 EDUs Yes
Water 3,740 GPD Yes
The project proposes 17 dwelling units whereas the maximum unit yield at the GMCP of the
property is 17.28 dwelling units. Consistent with the General Plan and Policy No. 43, 0.28 DUs
will be deposited into the City’s excess dwelling unit bank.
CT 12-01/PUD 12-08/CDP 12-15 – MILES PACIFIC SUBDIVISION
June 19, 2013
Page 12
V. ENVIRONMENTAL REVIEW
Pursuant to the California Environmental Quality Act (CEQA) and the Environmental Protection
Ordinance (Title 19) of the Carlsbad Municipal Code, staff has conducted an environmental
impact assessment to determine if the project could have any potentially significant impact on the environment. The environmental impact assessment identified potentially significant impacts to cultural resources, hazards/hazardous materials, and noise, and mitigation measures have been
incorporated into the design of the project or have been included as conditions of approval for
the project such that all potentially significant impacts have been mitigated to below a level of
significance. Based on the above, the City Planner issued a Notice of Intent to adopt a Mitigated Negative
Declaration (MND) for the project on March 14, 2013. Standard comment letters were received
during the 30-day public review (March 14, 2013 – April 15, 2013) from the Native American
Heritage Commission (San Luis Rey Band of Mission Indians), Department of Toxic Substances Control, and Caltrans. Their specific comments and staff’s responses are included as an attachment at the back of the MND. An addendum has also been prepared in accordance with
Section 15164 of CEQA to include clarifying language to mitigation measures CUL-1 and CUL-
2. These additions have no new significant environmental effects not analyzed in the previously
circulated MND, and none of the circumstances requiring recirculation or a subsequent Mitigated Negative Declaration under CEQA Guidelines Section 15162 exist. Furthermore, the minor changes to the EIA Part II do not require recirculation of the Mitigated Negative Declaration
since CEQA Section 15073.5(c)(4) states recirculation is not required if “new information is
added to the negative declaration which merely clarifies, amplifies, or makes insignificant
modifications to the negative declaration.” ATTACHMENTS:
1. Planning Commission Resolution No. 6985 (ND)
2. Planning Commission Resolution No. 6986 (CT 12-01) 3. Planning Commission Resolution No. 6987 (PUD 12-08) 4. Planning Commission Resolution No.6988 (CDP 12-15)
5. Location Map
6. Background Data Sheet
7. Local Facilities Impact Assessment Form 8. Disclosure Statement 9. Reduced Exhibits
10. Exhibits “A” – “I” dated June 19, 2013
Revised 01/06
BACKGROUND DATA SHEET
CASE NO: CT 12-01/PUD 12-08/CDP 12-15
CASE NAME: MILES PACIFIC SUBDIVISION
APPLICANT: bHA, Inc.
REQUEST AND LOCATION: Request for the adoption of a Mitigated Negative Declaration and Mitigation Monitoring and Reporting Program and Addendum, and the approval of a
Tentative Tract Map, Planned Development Permit, and Coastal Development Permit to allow
for the demolition of a single family residence, storage building, and green house structures, and
to subdivide and grade a 5.4 acre site into seventeen (17) single-family residential lots, one
private street lot, and two bio-retention basin lots, on property generally located on the west side of Pio Pico Drive near the intersection of Pio Pico Drive and Las Flores Drive within the Mello
II Segment of the Local Coastal Program and Local Facilities Management Zone 1.
LEGAL DESCRIPTION: A portion of Tract 7 of Laguna Mesa Tracts, in the City of
Carlsbad, County of San Diego, State of California, according to map thereof No. 1719, filed in the office of the County Recorder of San Diego County, June 21, 1921
APN: 156-351-03, 07 & 08 Acres: 5.4 Proposed No. of Lots/Units: 17 Single-family lots; one
private street lot; two bio-retention basin lots
GENERAL PLAN AND ZONING
Existing Land Use Designation: RLM
Proposed Land Use Designation: N/A
Density Allowed: 0 – 4 du/ac Density Proposed: 3.14 du/ac
Existing Zone: R-1 Proposed Zone: N/A
Surrounding Zoning, General Plan and Land Use:
Zoning General Plan Current Land Use
Site R-1 RLM Single-Family/Nursery
North R-1 RLM Single-Family
South R-1 RLM Single-Family
East R-1 RLM Single-Family
West T-C TC I-5 Freeway
LOCAL COASTAL PROGRAM
Coastal Zone: Yes No Local Coastal Program Segment: Mello II
Within Appeal Jurisdiction: Yes No Coastal Development Permit: Yes No Local Coastal Program Amendment: Yes No
Revised 01/06
Existing LCP Land Use Designation: RLM Proposed LCP Land Use Designation: N/A
Existing LCP Zone: R-1 Proposed LCP Zone: N/A
PUBLIC FACILITIES
School District: Carlsbad Unified Water District: Carlsbad Sewer District: Carlsbad
Equivalent Dwelling Units (Sewer Capacity): 17
ENVIRONMENTAL IMPACT ASSESSMENT
Categorical Exemption,
Mitigated Negative Declaration, issued June 19, 2013
Certified Environmental Impact Report, dated
Other,
CITY OF CARLSBAD
GROWTH MANAGEMENT PROGRAM
LOCAL FACILITIES IMPACTS ASSESSMENT FORM (To be Submitted with Development Application)
PROJECT IDENTITY AND IMPACT ASSESSMENT:
FILE NAME AND NO: Miles Pacific Subdivision – CT 12-01/PUD 12-08/CDP 12-15
LOCAL FACILITY MANAGEMENT ZONE: 1 GENERAL PLAN: RLM
ZONING: R-1: 7,500
DEVELOPER’S NAME: bHA, Inc.
ADDRESS: 5115 Avenida Encinas, Suite L, Carlsbad, CA 92008
PHONE NO.: 760-931-8700 ASSESSOR’S PARCEL NO.: 156-351-03, 07 & 08
QUANTITY OF LAND USE/DEVELOPMENT (AC., SQ. FT., DU): 5.4 AC.
ESTIMATED COMPLETION DATE: Unknown
A. City Administrative Facilities: Demand in Square Footage = 59.10
B. Library: Demand in Square Footage = 31.52
C. Wastewater Treatment Capacity (Calculate with J. Sewer) 17 EDU
D. Park: Demand in Acreage = .11
E. Drainage: Demand in CFS = 11.46
Identify Drainage Basin = A
(Identify master plan facilities on site plan)
F. Circulation: Demand in ADT = 170
(Identify Trip Distribution on site plan)
G. Fire: Served by Fire Station No. = 1
H. Open Space: Acreage Provided = N/A
I. Schools: E=5.78/M=2.01/
HS=1.75
(Demands to be determined by staff)
J. Sewer: Demands in EDU 17
Identify Sub Basin = 1D
(Identify trunk line(s) impacted on site plan)
K. Water: Demand in GPD = 3,740
L. The project is 0.28 dwelling units below the Growth Management Dwelling unit allowance. The project proposes 17 dwelling units whereas the maximum unit yield at the GMCP of the property is 17.28 dwelling units. Consistent with the General Plan and