HomeMy WebLinkAboutCT 94-02; Pacific Pointe; Tentative Map (CT) (16)City of Carlsbad
Planning Department
May 19, 1994
Gregory E. Harris
Lucas & Mercier Development, Inc.
29712 Avenida de la Banderas
Rancho Santa Margarita, CA 92688
SUBJECT: CT 94-02/PUD 94-01 - PACIFIC POINTE
Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning Department
has reviewed your Tentative Map and Planned Development Permit, application nos. CT 94-02/PUD
94-01, as to its completeness for processing.
The items requested from you earlier to make your Tentative Map and Planned Unit Development
application nos. CT 94-02/PUD 94-01 complete have been received and reviewed by the Planning
Department. It has been determined that the application is now complete for processing. Although
the initial processing of your application may have already begun, the technical acceptance date is
acknowledged by the date of this communication.
Please note that although the application is now considered complete, there may be issues that
could be discovered during project review and/or environmental review. Any issues should be
resolved prior to scheduling the project for public hearing. In addition, the City may request, in
the course of processing the application, that you clarify, amplify, correct, or otherwise, supplement
the basic information required for the application.
Please contact your staff planner, Terri Woods, at (619) 438-1161 extension 4447, if you have any
questions or wish to set up a meeting to discuss the application.
Sincerely,
MICHAEL J. HOLZMILLER
Planning Director
MJH:TW:vd
c: Gary Wayne
Adrienne Landers
Bobbie Hoder
Bob Wojcik
File Copy
Data Entry
Marjorie/Rich
Rod Bradley, BHA, Inc.
2O75 Las Palmas Drive • Carlsbad, California 92OO9-1576 • (619)438-1161
ISSUES OF CONCERN
No. CT 94-02/PUD 94-01 - PACIFIC POINTE
PLANNING:
1. We have reviewed the revised elevations and floor plans submitted. It appears plans meet
the requirements of the Small Lot Guidelines. Please revise the Architectural Guideline
Compliance Summary to reflect the changes made on the plans. I have enclosed a redline
copy of the summary sheet.
2. Please note that the proposed chain link fencing on the project is not acceptable. Other
fencing materials including wood, block, stucco, wrought iron or other similar fencing
materials should be considered.
3. The noise report submitted concludes that no outside noise mitigation is necessary to meet
City noise standards but that interior noise mitigation would be necessary. The project
would be conditioned to comply with the noise mitigation measures in the noise study.
PACIFIC POINTE
ARCHITECTURAL GUIDELINE COMPLIANCE SUMMARY
GUIDELINE
1. WHERE (3) TWO-STORY UNITS OCCUR IN A ROW AND THEY ARE
SITUATED LESS THAN 15 FEET APART, AT LEAST (1) UNIT MUST
HAVE A SINGLE STORY BUILDING EDGE NOT LESS THAN 10
FEET IN DEPTH.
2. WHERE (3) TWO-STORY UNITS OCCUR IN A ROW AND THEY ARE
SITUATED 1 5 TO 20 FEET APART. AT LEAST (1) UNIT MUST HAVE A
SINGLE STORY BUILDING EDGE NOT LESS THAN 5 FEET IN DEPTH.
3. PER PROJECT, 33% OF ALL UNITS SHALL HAVE A SINGLE STORY
EDGE A MINIMUM OF 40% OF THE TOTAL PERIMETER.
4. PER PROJECT, 50% OF ALL UNITS WITH A LOT FRONTAGE OF
45 FEET OR LESS MUST HAVE (3) SEPARATE BUILDING PLANES
ON THE FRONT ELEVATION.
5. PER PROJECT, 50% OF ALL UNITS WITH A LOT FRONTAGE OF
45 FEET OR LESS MUST HAVE (3) SEPARATE BUILDING PLANES ON
THE REAR ELEVATION.
6. PER PROJECT, 50% OF ALL UNITS SHALL HAVE ONE SIDE
ELEVATION WITH A 7 FEET AVERAGE SIDEYARD SETBACK.
17. THREE-CAR GARAGES LIMITED TO 75% OF THE TOTAL UNITS
WHERE AVERAGE LOT SIZE IS 5,000 SF OR LESS.
8. 50% OF EXTERIOR DOOR AND WINDOW OPENINGS SHALL BE
PROJECTED OR RECESSED A MINIMUM OF 2 INCHES.
9. EACH PRODUCT SHALL EXHIBIT DIRECTIONAL VARIETY
IN ITS ROOF FRAMING.
MINIMUM
STANDARD
10F3
1OF3
33%
50%
50%
50%
75%
50%
100%
PRODUCT
1
10F3
N/A
N/A
100%
^r
100%
100%
100%
100%
PRODUCT
2
N/A
N/A
66%
100%
trr
100%
100%
100%
100%
COMMENT
WE ONLY HAVE 3 UNITS IN A ROW AND PLAN 1 IS THE
UNIT THAT HAS A SINGLE STORY ELEMENT. flW-
THE GUIDELINE DOES NOT APPLY.
ALL OF OUR UNITS ARE LESS THAN 1 5 FEET APART.
WE HAVE FOUR OF THE NO. 2 UNITS PLOTTED.
UN\T (N/o. Z. V~iAs A siMt^lg, -svc-e.^- BundHvffe
ALL OF OUR UNITS SATISFY THIS GUIDELINE
\jNtT Nta>- Z- *~>P>*> ~"W%v^e •Se^AKArfe f<Jttixo(X PtAfit
ON TH"(5, K^AR EA~C\'ATVOhi. \— DVAV^ Of Tl\^ Svx Ve»~t"c
VJ l\\ t>£ ^-^~^VC.JCi \MxtH ^OwF-xVT iNo. $. ^
EACH UNIT HAS ONE SIDE ELEVATION WITH OFFSETS SO
THAT WE MAINTAIN AT LEAST A 7 FOOT AVERAGE
SETBACK.
WE ARE NOT PROPOSING ANY THREE-CAR GARAGES.
ALL OF THE EXTERIOR DOORS AND WINDOWS HAVE
PROJECTIONS.
ALL OF THE ROOFS EXHIBIT DIRECTIONAL VARIETY.