HomeMy WebLinkAboutCT 99-02; Poinsettia Properties Planning Area 7; Tentative Map (CT) (27)05/27/1999 10:32 7604382443 HOFMAN PLANNING PAGE 01
Hofman Planning
Associates
Planning Project Management Rscal Analysis
Date: May 27, 1999
Project Poinsettia Cove
FAX: 438-0894
No. Pages: 3
Attention: Barbara Kennedy
If all pages are not received, please call (760) 436-1465.
Message: The following is the guideline text for the Poinsettia Cove
deck/trellis exhibit. The guidelines are very similar to what was
used in PAS with the exception of #3 of the Specific Development
Standards.
If you have any questions or comments, please feel free to call
me at 438- 1465.
From: Stuart Fisk(JK)
5900 Pasteur Court • StelSO * Carlsbad • CA • 92008 • 760-438-1465 • Fox 760-438-2443
CS
CS
IS
enen
IDo
POINSETTIA COVE
BALCONY/DECK DESIGN GUIDELINES
THE FOLLOWING ARE DESIGN GUIDELINES/STANDARDS FOR BALCONIES AND DECKS WITHIN PLANNING AREA 7 OF THE POINSETTIA PROPERTIES
SPECIFIC PLAN. THE PURPOSE OF THE DESIGN GUIDELINES IS TO PERMIT THE CONSTRUCTION OF BALCONIES/DECKS THAT ARE AESTHETICALLY
PLEASING AND UNOBTRUSIVE. THE DESIGN GUIDELINES ARE ACCOMPANIED BY A BALCONY/DECK EXHIBIT THAT IDENTIFIES WHICH UNITS MAY
HAVE BALCONIES/DECKS AND THE LOCATION OF THE BALCONY/DECK ON A UNIT BY UNIT BASIS.
BASIC REQUIREMENTS-
ALL BALCONIES/DECKS SHALL COMPLY WITH THE REQUIREMENTS OF THE UNIFORM BUILDING CODE.
PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR A BALCONY/DECK, PROOF MUST BE SHOWN THAT THE BALCONY/DECK HAS BEEN
APPROVED BY THE HOMEOWNERS ASSOCIATION. APPROVAL BY THE HOMEOWNERS ASSOCIATION IS DISCRETIONARY AS OUTLINED IN THE
CCAR's {HOA LETTER AND/OR HOA STAMP ON PLANS).
3. A BALCONY/DECK MUST BE OF COLOR AND DESIGN THAT IS COMPATIBLE WITH THE DWELLING UNIT.
4. A BALCONY/DECK MUST MAINTAIN ALL SETBACK REQUIREMENTS AS SPECIFIED IN THE POINSETTIA PROPERTIES SPECIFIC PLAN, THE
PLANNED DEVELOPMENT ORDINANCE OR THE BALCONY/DECK DESIGN GUIDELINES, WHICHEVER IS MOST RESTRICTIVE
5. NO BALCONY/DECK MAY INTRUDE INTO ANY YARD SO AS NOT TO COMPLY WTTH SECTION 21.46.120 OF THE CITY ZONING ORDINANCE.
6. A BALCONY/DECK IS PERMITTED ONLY ON THE UNITS SPECIFICALLY IDENTIFIED AS ALLOWING FOR A BALCONY/DECK PER THE BALCONY/DECK
EXHIBIT.
SPECIFIC DEVELOPMENT STANDARDS -
1. THE OUTSIDE EDGE OF A BALCONY/DECK MUST MAINTAIN A MINIMUM DISTANCE OF TEN (10) FEET FROM ANY ADJOINING DWELLING UNIT OR
OTHER BALCONY/DECK POST.
2. A BALCONY/DECK MUST MAINTAIN A MINIMUM OF FIVE (5) FEET FROM A FENCE. SOUND WALL OR COMMUNITY WALL
3. THE LOCATION OF BALCONIESVDECKS MAY BE MODIFIED FROM THE COVERAGE AREA SPECIFICALLY IDENTIFIED BY THE BALCONY/DECK
EXHIBIT, SUBJECT TO THE APPROVAL OF THE HOMEOWNERS ASSOCIATION AND THE CITY OF CARLSBAD PLANNING DEPARTMENT.
U
POINSETTIA COVE
TRELLIS/PATIO COVER DESIGN GUIDELINES
THE FOLLOWING ARE DESIGN GUIDELINES/STANDARDS FOR TRELLIS/PATIO COVERS WITHIN PLANNING AREA 7 OF THE POINSETTIA PROPERTIES
SPECIFIC PLAN. THE PURPOSE OF THE DESIGN GUIDELINES IS TO PERMIT THE CONSTRUCTION OF TRELLIS/PATIO COVERS THAT ARE
AESTHETICALLY PLEASING AND UNOBTRUSIVE. THE DESIGN GUIDELINES ARE ACCOMPANIED BY A TRELLIS/PATIO COVER EXHIBIT THAT IDENTIFIES
WHICH UNITS MAY HAVE TRELLIS/PATIO COVERS AND THE LOCATION OF THE TRELLISPATIO COVER ON A UN(T BY UNIT BASIS.
SIC REQUIREMENTS-
ALL TRELLIS/PATIO COVERS SHALL COMPLY WITH THE REQUIREMENTS OF THE UNIFORM BUILDING CODE.
PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR A TRELLIS/PATIO COVER, PROOF MUST BE SHOWN THAT THE TRELLIS/PATIO COVER HAS
BEEN APPROVED BY THE HOMEOWNERS ASSOCIATION. APPROVAL BY THE HOMEOWNERS ASSOCIATION IS DISCRETIONARY AS OUTLINED IN
?! THE CC&R'S (HOA LETTER AND/OR HOA STAMP ON PLANS).
a! 3. A TRELUS/PATIO COVER MUST BE OF COLOR AND DESIGN THAT IS COMPATIBLE WITH THE DWELLING UNIT.
z 4. ROOFING MATERIALS FOR A PATIO COVER MUST BE THE SAME OR NEAR THE SAME STYLE AND COLOR AS THE DWELLING UNIT.
i 5. A TRELLIS/PATIO COVER MUST MAINTAIN ALL SETBACK REQUIREMENTS AS SPECIFIED IN THE POINSETTIA PROPERTIES SPECIFIC PLAN, THE
o PLANNED DEVELOPMENT ORDINANCE OR THE TRELLIS/PAT1O COVER DESIGN GUIDELINES, WHICHEVER IS MOST RESTRICTIVE.
6. NO TRELLIS/PATIO COVER MAY INTRUDE INTO ANY YARD SO AS NOT TO COMPLY WITH SECTION 21.46.120 OF THE CITY ZONING ORDINANCE.
7. TRELLIS/PATIO COVERS ARE PERMITTED ONLY ON THE UNITS SPECIFICALLY IDENTIFIED AS ALLOWING FOR TRELLIS/PATIO COVERS PER THE
TRELLIS/PATIO COVER EXHIBIT.
SPECIFIC DEVELOPMENT STANDARDS -
1. THE OUTSIDE EDGE OF A TRELLIS/PAT1O COVER MUST MAINTAIN A MINIMUM DISTANCE OF TEN (10) FEET FROM ANY ADJOINING DWELLING
UNIT OR OTHER TRELLIS/PATIO COVER POST A MAXIMUM OF TWO (2) FEET OVERHANG IS ALLOWED PAST THE POST.
2. A TRELLIS/PATIO COVER MUST MAINTAIN A MINIMUM OF FIVE (5) FEET FROM A FENCE, SOUND WALL OR COMMUNITY WALL
3. THE LOCATION OF BALCONIES/DECKS MAY BE MODIFIED FROM THE COVERAGE AREA SPECIFICALLY IDENTIFIED BY THE BALCONY/DECK
EXHIBIT, SUBJECT TO THE APPROVAL OF THE HOMEOWNERS ASSOCIATION AND THE CITY OF CARLSBAD PLANNING DEPARTMENT.
O
(jO
(N
C")
enenen
<N
tn