HomeMy WebLinkAboutCT 99-14; The Regency; Tentative Map (CT) (28)Date: 17 September 1999
To: Barbara Kennedy
From: Principal Building Inspector
Re: 11 PUD for Bemie Reeder
Barbara - This plan shows real property lines between the dwelling units. The
elevations and roof plans show some architectural features that will not be approved
in building plan check due to proximity to property lines.
Generally, walls next to property line need parapets or other fire-resistive features in
the roof system. This is achievable except at the gables on the front elevations of the
duplexes. That roof overhang at the gables from one property to another property is
essentially a combustible projection over the property line. This is prohibited in the
UBC. A re-design of this elevation is strongly recommended.
The designer may call me directly w/ further questions at (760) 438-1161 , extension
4503.
PAT KELLEY
Principal Building Inspector
' Page 1