HomeMy WebLinkAboutCT 99-20; Carlsbad Airport Center Lot 10; Tentative Map (CT) (17)•
August 11, 1998
TO: Principal Planner DeCerbo
FROM: Associate Engineer Steven Jantz 3. ^-J-
PRE 98-40 - McMAHON DEVELOPMENT GROUP HOTEL
Engineering Department staff have completed a review of the above-referenced. Based on the
contents provided, the following comments are submitted for your and the applicants
consideration for the proposed project:
1. Due to the length of the driveway, the applicant should consider two access points from
Owens Avenue. Dual driveways will provide an additional access for safety vehicles and
reduce the length of a single entrance driveway.
2. The driveways throughout the site must maintain a minimum of 24' clearance. The cul-de-
sac bulb must conform to a 32' radius to the back of the parking spaces.
3. The applicant must secure and show proof of a parking agreement with SDG&E for that
area within the 200' easement.
4. The applicant must ensure that the roof drains do not drain over the slope bank and should
be tied into an approved storm drain system.
5. The plan does not show topography or proposed grading quantities. A grading permit may
be required.
6. The project must comply with the provisions of the National Pollutant Discharge
Elimination System (NPDES) program.
7. The applicant should check with the Fire Department relative to the length of the driveway
access and potential fire hydrant locations
8. The applicant should check with the Carlsbad Municipal Water District for water service
requirements.
If you have any questions or need further clarification, please contact me at extension 4354.