HomeMy WebLinkAboutCUP 154C; Pacific Bell Expansion; Conditional Use Permit (CUP) (31)96050 Bureau of Prevention City of Carlsbad Fire Department Plan Review: Requirements Category: Fire Conditions 1 Date of Report: Monday, March 4,1996 Contact Name Terry Woods Reviewed by: Address City, State Bldg. Dept. No. Job Name Pacific Bell Exp Job Address 2175 Camino Vida Roble - Ste. or Bldg. No. fL hi c a hk,t& - The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. 0 Disapproved - Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this off ice for review. For Fire Department Use Only Review 1st 2nd 3rd CFD Job# 96050 File# Other Agency ID I 2560 Orion Way Carlsbad, California 92008 (619) 931-2121 - - ,- Requirements klre Conditions 96050 Deficiency Item:- 08 Fire lanes Prior to building occupany, private roads and driveways which serve as required access for emergency service vehicles shall be posted as fire lanes in accordance with the requirements of section 17.04.020 of the Carlsbad Municipal Code. Deficiency Item: 09 Brush clearance 7 Native vegetation which presents a fire hazard to structures shall be modified or removed in dccordance‘ with the specifications contained in the City of Carlsbad Landscape Guidelines Manual. Applicant shall submit a Fire Suppression plan to the Fire Department for approval. Proposed new condition Prior to issuance of the building permit, the applicant shall obtain fire department approval of a wildland fuel management plan. The plan shall clearly indicate methods proposed to mitigate and manage fire risk associated with native vegetation growing within 60 feet of structures. The plan shall reflect the standards presented in the fire suppression element of the City of Carlsbad Landscape Guidelines Manual. morebdow Prior to occupancy of buildings, all wildland fuel mitigation activities must be complete, and the condition of all vegetation within 60 feet of structures found to be in conformance with an approved wildland fuel management plan. 10 Fire protection systems- sprinklers, alarms, standpipes specifications for fire alarm systems, fire hydrants, automatic fire sprinkler systems and Deficiency Item: other fire protection systems shall be submitted to the Fire Department for approval prior to P &” construction. groposed language All buildings having an aggregate floor area in excess of 10,000 square feet must be protected by automatic fire sprinkler systems. Plans and specifications must be approved by the fire department, and a permit obtained prior to installation. Proposed multifamily residential buildings must be protected by fire alarm systems. Plans and specifications must be approved, and a permit obtained prior to installation. Deficiency Item: 11 Sprinklers required for buildings over 10,000 sq ft in area An appro d automatic fire sprinkler system shall be installed in buildings having an aggregate floor ”? =ding 10,000 square feet. Delete Deficiency Item: 12 Emergency response maps nt shall provide a street map which conforms to the following requirements: A 400 scale 3-’‘ &\ photo-reduction mylar, depicting proposed improvements and at least two existing intersections or streets. The map shall also clearly depict street centerlines, hydrant locations and street names. fdF Page 3 03/04/96 Requirements Category: I e Conditions 96050 Deficiency Item: 01 Building Permits 1 Prior to the issuance of building permits, complete building plans shall be approved by the Fire Department. Proposed language: Prior to issuance of building permits, the Fire Department shall evaluate building plans for conformance with applicable fire and life safety requirements of the state and local Fire Codes. Additional on-site public water mains and fire hydrants are required. Proposed change for Industrial and multi family: Provide additional public fire hydrants at intervals of 300 feet along public streets and private driveways. Hydrants should be located at street intersections when possible, but should be positioned no closer than 100 feet from terminus of a street or driveway. Proposed change for single family residences: Provide additional public fire hydrants at intervals of 500 feet along public streets and/or private driveways. Hydrants should be located at street intersections when possible, but should be positioned no closer than 100 feet from terminus of a street or driveway. Deficiency Item: 03 Site Plan/Hydrants 1 ApplicanEhall submit a site plan to the Fire Department for approval, which depicts location of required, proposed and existing public water mains and fire hydrants. The plan should include off-site fire hydrants within 200 feet of the project. fbn J Site plan/access - O4 Deficiency Item: tcfi J 1hZ Applicant shall submit a site plan depicting emergency access routes, driveways and traffic circulation for Fire Department approval. Deficiency Item: 05 Access during construction An all weather, unobstructed access road suitable for emergency service vehicles shall be provided and maintained during construction. When in the opinion of the Fire Chief, the access road has become unserviceable due to inclement weather or other reasons, he may, in the interest of public safety, require that construction operations cease until the condition is corrected. fi,J ,hq All required water mains, fire hydrants and appurtenances shall be operational before combustible building materials are located on the construction site. I Pol Deficiency Item: 07 Security gate systems 6 Prior to final inspection, all security gate systems controlling vehicular access shall be equipped with a "Knox", key-operated emergency entry device. Applicant shall contact the Fire Prevention Bureau for specifications and approvals prior to installation. Page 2 Mar 4,1996 I - *- L - 96050 Fire Department Bureau of Prevention City of Carlsbaa General Commeljts: Contact Name. Terry Woods Address City, State CA Bldg. Dept. No. Job Name Pacific Bell Exp Building will have to be sprinklered! Ste. or Bldg. No. 2560 Orion Way Carls bad, California 92008 (619) 931-2121