Loading...
HomeMy WebLinkAboutMCUP 12-03; Olivenhain PCS SD03XC183; Conditional Use Permit (CUP) (2)<<~• ~ CITY OF CARLSBAD LAND USE REVIEW APPLICATION P-1 Development Services Planning Division 1635 Faraday Avenue (760} 602-4610 www.carlsbadca .gov APPLICATIONS APPLIED FOR: (CHECK BOXES) Development Permits (FOR DEPT. USE ONLY) Legislative Permits (FOR DEPT. USE ONLY) 0 Administrative Permit 0 General Plan Amendment 0 Coastal Development Permit (*) 0 Mino r 0 Local Coastal Program Amendment (*) '81 Conditional Use Permit (*) ~ ,,~, 0 Master Plan 0Amendment ~ Minor [] Extension 0 Environmental Impact Assessment 0 Habitat Management Permit 0 Hillside Development Permit (*) 0 Planned Development Permit 0Mino 0 Residential 0 Non-Residential 0 Planned Industrial Permit 0 Planning Commission Determination 0 Site Development Plan 0 Special Use Permit 0 Tentative Tract Map 0 Variance 0 Administrative r D Specific Plan D Zone Change(*) 0Amendment D Zone Code Amendment South Carlsbad Coastal Review Area Permits D Review Permit D Administrative 0 Minor 0 Major Village Review Area Permits D Review Permit D Administrative 0 Minor 0 Major (*) = eligible for 25% discount NOTE: A PROPOSED PROJECT REQUIRING MULTIPLE APPLICATIONS MUST BE SUBMITTED PRIOR TO 3:30P.M. A PROPOSED PROJECT REQUIRING ONLY ONE APPLICATION MUST BE SUBMITTED PRIOR TO 4:00P.M. ASSESSOR PARCEL NO(S).: 255-031-03-00 y~ PROJECT NAME: Oli venhain .,t--"m38JJEC18~ :Net· .. ·erk ViBiea l'4oee::~:;g,ililia:'E:ien PrO) cet BRIEF DESCRIPTION OF PROJECT: Modify existing unmanned telecommunications facility: removing 7 panel antennas; installing 3 new panel antennas. See plans for more details BRIEF LEGAL DESCRIPTION: Portion of lot 10 of the subdivision of the rancho los encinitas in the county of San Diego, according to Map No. 843, filed June 27, 1896. LOCATION OF PROJECT: 1966 Olivenhain Rd., Carlsbad, CA 92009 ON THE: BElWEEN P-1 South (NORTH, SOUTH, EAST, WEST) Amargosa Dr. (NAME OF STREET) SIDE OF AND STREET ADDRESS Olivenhain Rd. (NAME OF STREET) Rancho Santa Fe Rd. (NAME OF STREET) Page 1 of6 Revised 06/12 c OWNER NAME (Print): Olivenhain Muni Water Dist MAILINGADDRESS: 1966 Olivenhain Rd CITY, STATE, ZIP: Carlsbad, CA, 92024 TELEPHONE: 760-753-6466 -------------------------EMAIL ADDRESS: I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOW DGE. MAILING ADDRESS: CITY, STATE, ZIP: TELEPHONE: EMAIL ADDRESS: IN THE PROCESS OF REVIEWING THIS APPLICATION IT MAY BE NECESSARY FOR MEMBERS OF CITY STAFF, PLANNING COMMISSIONERS OR CITY COUNCIL MEMBERS TO INSPECT AND ENTER THE PROPERTY THAT IS THE SUBJECT OF THIS APPLICATION. 1/WE CONSENT TO ENTRY FOR THIS PURPOSE. NOTICE OF RESTRICTION: PROPERTY OWNER ACKNOWLEDGES AND CONSENTS TO A NOTICE OF RESTRICTION BEING RECORDED ON THE TITLE TO HIS PROPERTY IF CONDITIONED FOR THE APPLICANT. NOTICE OF RESTRICTIONS RUN WITH ~TH~E~LA~N;A~N~D~B~IN~D~AiN~Y~S~C~C~E~S!SO~R~S~I~N~IN~T~E~ES~T~·~c;; ee ~ ~ FOR CITY USE ONLY P-1 Page 2 of6 . RECEIVED AUG 0 3 7m2 CITY OF CARLSBAD PLANNING DIVISION DATE STAMP APPLICATION RECEIVED RECEIVED BY: :tl I db Revised 06/12 «~~' ~ CITY OF DISCLOSURE STATEMENT P-1(A) Development Services Planning Division 1635 Faraday Avenue {760) 602-4610 www.carlsbadca.gov CARLSBAD Applicant's statement or disclosure of certain ownership interests on all applications which will require discretionary action on the part of the City Council or any appointed Board, Commission or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print. Note: Person is defined as "Any individual, finn, co-partnership, joint venture, association, social dub, fraternal organization, corporation, estate, trust, receiver, syndicate, in this and any other county, city and county, city municipality, district or other political subdivision or any other group or combination acting as a unit" Agents may sign this document; however, the legal name and entity of the applicant and property owner must be provided below. 1. APPLICANT (Not the applicant's agent) Provide the COMPLETE. LEGAL names and addresses of ALL persons having a financial interest in the application. If the applicant includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separat~may be attached if necessary.) Person ~~ Corp/Part Sprint Spectrum LP Title Authorized Agent for Sprint Title, _____________ _ Address _________ _ Address 6391 Sprint Pkwy, overland PK KS 66251 2. OWNER (Not the owner's agent) P-1(A) Provide the COMPLETE. LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (i.e., partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person, __________ _ Corp/Part Olivenhain Muni Water Dist. Title. ___________ _ Title. _____________ _ Address _________ _ Address 1966 Olivenhain Rd., Carlsbad, CA 92024 Page 1 of2 Revised 07/10 3. NON-PROFIT ORGANIZATION OR TRUST If any person identified pursuant to (1) or (2) above is a nonprofit organization or a trust, list the names and addresses of ANY person serving as an officer or director of the non- profit organization or as trustee or beneficiary of the. Non Profit/Trust Non Profit/Trust. _________ _ Title Title. ____________ _ Address. _________ _ Address. ___________ _ 4. Have you had more than $500 worth of business transacted with any member of City staff, Boards, Commissions, Committees and/or Council within the past twelve (12} months? ___.../ D Yes l::J No If yes, please indicate person(s): __________ _ NOTE: Attach additional sheets if necessary. I certify that all the above information is true and correct to the b See LOA Signature of owner/date ~(Authorized Print or type name of applicant Agent) P-1(A) Page 2 of2 Revised 07/10 «~'' ~ CITY OF CARLSBAD HAZARDOUS WASTE AND SUBSTANCES STATEMENT P-1(C) Development Services Planning Division 1635 Faraday Avenue {760) 602-4610 www.carlsbadca.gov Consultation of Lists of Sites Related to Hazardous Wastes (Certification of Compliance with Government Code Section 65962.5) Pursuant to State of California Government Code Section 65962.5, I have consulted the Hazardous Waste and Substances Sites List compiled by the California Environmental Protection Agency and hereby certify that (check one): lXI The development project and any alternatives proposed in this application are not contained on the lists compiled pursuant to Section 65962.5 of the State Government Code. 0 The development project and any alternatives proposed in this application !!:!. contained on the lists compiled pursuant to Section 65962.5 of the State Government Code. APPLICANT Name.E4'.6tA-(Authorized Agent for Sprint) Address: 37753 Spruce Ct., Murrieta, CA 92562 PROPERTY OWNER Name: Olivenhain Muni Water Dist Address:1966 Olivenhain Rd. Carlsbad, CA 92024 Phone Number: 310-903-864 0 Phone Number: 760-753-6466 AddressofSite: 1966 Olivenhain Rd., Carlsbad, CA 92009 LocaiAgency(CityandCounty): City of Carlsbad, San Diego County, CA Assessor's book, page, and parcel number:_2_5_5_-_0_3_1_-_0_3_-_o_o ____________ _ Specify list(s):____,.:u,_,j;::ilo..--------------------------- Regulatory Identification Number:, _______________________ _ The Hazardous Waste and Substances Sites List (Cortese List) is used by the State, local agencies and developers to comply with the California Environmental Quality Act requirements in providing information about the location of hazardous materials release sites. P-1(C) Page 1 of2 Revised 07/10 «~f' ~ CITY OF CARLSBAD TIME LIMITS ON DISCRETIONARY PROJECTS P-1(E) PLEASE NOTE: Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov Time limits on the processing of discretionary projects established by state law do not start until a project application is deemed complete by the City. The City has 30 calendar days from the date of application submittal to determine whether an application is complete or incomplete. Within 30 days of submittal of this application you will receive a letter stating whether this application is complete or incomplete. If it is incomplete, the letter will state what is needed to make this application complete. When the application is complete, the processing period will start upon the date of the completion letter. If you have any questions regarding application submittal requirements (i.e., clarification regarding a specific requirement or ether requirements are necessary for your particular application) please call (760) 6 '"' Applicant Signature: Staff Signature: Date: To be stapled with receipt to the application P-1(E) Page 1 of 1 Revised 07/10 & ~ CITY OF CARLSBAD STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov To address post-development pollutants that may be generated from development projects, the City requires that new development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMP's) into the project design per the City's Standard Urban Stormwater Management Plan (SUSMP). To view the SUSMP, refer to the Engineering Standards (Volume 4, Chapter 2) at www.carlsbadca.gov/standards. Initially this questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to 'Standard Stormwater Requirements' or be subject to additional criteria called 'Priority Development Project Requirements'. Many aspects of project site design are dependent upon the storm water standards applied to a project. Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by you, this will result in the return of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the City. If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, please seek assistance from Land Development Engineering staff. A separate completed and signed questionnaire must be submitted for each new development application submission. Only one completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently. In addition to this questionnaire, you must also complete, sign and submit a Project Threat Assessment Form with construction permits for the project. Please start by completing Section 1 and follow the instructions. When completed, sign the form at the end and submit this with your application to the city. Examples: single family homes, multi-family homes, Restaurants. Any facility that sells prepared foods and drinks for consumption, including stationary lunch counters and refreshment stands selling prepared foods and drinks for immediate consumption (SIC code 5812), where the land area for development is greater than 5,000 square feet. Restaurants where land development is less than 5,000 square feet shall meet all SUSMP requirements except for structural treatment BMP and numeric sizing criteria and · E-34 Page 1 of 3 REV 1/14/11 X X X X X 6. 7. 8. 9. ~ ~ CITY OF CARLSBAD STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov Hillside development. Any development that creates more than 5,000 square feet of impervious surface and is located in an area with known erosive soil conditions, where the development will grade on any natural slope that is X twenty-five percent (25%) or greater. Envlronmentallv Sensitive Area fESAJ1• All development located within or directly adjacent2 to or discharging directly' to an ESA (where discharges from the development or redevelopment will enter receiving waters within the X ESA), which either creates 2,500 square feet or more of impervious surface on a proposed project site or increases the area of imperviousness of a proposed project site 10% or more of its naturally occurring condition. Parking lot. Area of 5,000 square feet or more, or with 15 or more parking spaces, and potentially exposed to urban X runoff Streets, roads, highways, and freeways. Any paved surface that is 5,000 square feet or greater used for the X transportation of automobiles, trucks, motorcycles, and other vehicles 10. Retail Gasoline Outlets. Serving more than 100 vehicles per day and greater than 5,000 square feet X 11. Coastal Development Zone. Any project located within 200 feet of the Pacific Ocean and (1) creates more than X 2500 square feet of impervious surface or (2) increases impervious surface on property by more than 10%. 12. More than 1-acre of disturbance. Project results in the disturbance of 1-acre or more of land and is considered a X Pollutant-generating Development Project4. .. 1 EnVIronmentally Sensitive Areas Include but are not 11m1ted to all Clean Water Act Section 303(d) 1mpa1red water bodies, areas designated as Areas of Spec1al Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their equivalent under the Multi Species Conservation Program within the Cities and County of San Diego; and any other equivalent environmentally sensitive areas which have been identified by the Copermittees. 2 "Directly adjacent" means situated within 200 feet of the Environmentally Sensitive Area. 3 "Discharging directly to" means outftow from a drainage conveyance system that is composed entirely of flows from the subject development or redevelopment site, and not commingled with flow from adjacent lands. 4 Pollutant-generating Development Projects are those projects that generate pollutants at levels greater than background levels. In general, these include all projects that contribute to an exceedance to an impaired water body or which create new impervious surfaces greater than 5000 square feet and/or introduce new landscaping areas that require routine use of fertilizers and pesticides. In most cases linear pathway projects that are for infrequent vehicle use, such as emergency or maintenance access, or for pedestrian or bicycle use, are not considered Pollutant-generating Development Projects if they are built with pervious surfaces or if they sheet flow to surrounding pervious surfaces. INSTRUCTIONS: Section 1 Results: If you answered YES to ANY of the questions above, your project is subject to Priority Development Project requirements. Skip Section 2 and please proceed to Section 3. Check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3. Additional storm water requirements will apply per the SUSMP. If you answered NO to ALL of the questions above, then please proceed to Section 2 and follow the instructions. E-34 Page 2of3 REV 1/14/11 & ~ CITY OF CARLSBAD STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services land Development Engineering 1635 Faraday Avenue 76Q-602-2750 www .carlsbadca.gov X X you you you subject to PRIORITY PROJECT requirements. Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below. Review SUSMP to find out if SUSMP requirements apply to your project envelope or the entire project site. If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS. Please check the "does not meet PDP requirements" box in Section 3 below. *for definition see Footnote 4 on page 2 D My project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stormwater criteria per the SUSMP and I understand I must prepare a Storm Water Management Plan for submittal at time of application. I understand flow control (hydromodification) requirements may apply to my project. Refer to SUSMP for details. ~ My project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per the SUSMP. As of these I will develo Applicant Information and Signature Box This Box for City Use Only Address: Assessor's Parcel Number(s): City Concurrence: I YES I NO 1966 Olivenhain 255-031-03-00 I I Applicant Title: By: Authorized Agent for Sprint Date: Project 10: E-34 Page 3of3 REV 1/14/11 0 './ -j' SureS1te Transmittal To: City of Carlsbad Planning Division 1635 Faraday Ave. Carlsbad, CA 92024 From: Ed Gala SureSite Consulting Group, LLC (714) 709-1523 e.gala@sure-site.com Date: 7/28/2012 0 Re: Conversion of CUP 99-02 to MCUP and Modification of Existing Facility. Included with this transmittal are the following docs: 1. Completed Land Use Review Application Form 2. Disclosure Statement Form 3. Two (2) copies of Property Profile 4. Two (2) copies of Letter of Authorization signed by underlying property owner. (NA city owned property. Proposed project is in conformance with lease maintenance provisions, no landlord authorization needed.) 5. Two (2) copies of Grant Deed 6. Two (2) copies of Storm Water Standards Questionnaire 7. Completed Project Description Letter 8. Four (4) sets of 11x17 plans showing proposed changes 9. One (1) set of as-built drawings 10. Signed "Notice of Time Limits on Discretionary Applications" SureSite Consulting Group, LLC 5955 DeSoto Ave. Suite 142 1 Woodland Hills, California 91367 1 tel216-593-0400 1 fax 216-593-0401 affiliated with Catalyst Commercial Realty, LLC 0 11. Signed "Hazardous Waste and Substance Statement" form 12. Copy of Conditional Use Permit 99-02 13. Copy of RRH Spec Sheet 14. Copy of new antenna spec sheets (APXVRR13-C-NA20 & 7762.00-A) 15. Documentation of Modernization 16. Photographs/Sims • Page2 c Sprint-Alcatel-Lucent Mal/atop: KSOPHT0101·Z2650 6391 Sprint Parkway Overland Parle, KS 66251 March 1, 2012 RE: Sprint Wireless Broadcast Facilities Subject: Letter of Authorization for Alcatei-Lucent Dear Sir or Madam: 0 Sprint'· t The intent of this letter is to provide notification that Sprint has engaged Alcatei- Lucent to evaluate site conditions and perform construction at multiple Sprint facilities around the country. These services may include performing on-site inspections and studies, and application for, or negotiations of, additional rights and entitlements for the facility. If modifications to our current real estate agreement are necessary, Alcatei-Lucent is authorized to perform these services on behalf of Sprint. This authorization is valid for Sprint "Network Vision" project and is effective until March 1, 2013. Sprint Nextel values its relationships with our landlords and the communities where our facilities are located and has instructed Alcatei-Lucent to protect our good standing in all matters. To that extent, please accept this as our authorization for you allow access to the site and to discuss possible changes that may be proposed at the facility with Alcatei-Lucent. In the event that you have questions related to this project and need to speak with Alcatei-Lucent, please contact Rachael Young at 913-338-8835. If you are dissatisfied with any aspect of the performance of Alcatei-Lucent, please ask them to provide the Sprint representative contact information for the project. For non-project-related issues you may contact the Sprint Landlord Relations Hotline at LandlordSolutions@Sprint.com or 800-357-7641. The Sprint Landlord Relations Hotline group CANNOT help you with work that is being done by the vendors mentioned above, but only deals with routine dally operational issues that arise at our sites. Thank you for your support and consideration. Sincerely, ~#~ Alba Barber Project Manager· SPRINT : 1.: ' I i 'I c Alcatel· Lucent 8 September 16, 2011 To Whom it May Concern: 0 San Dleao Off.ce 9605 Scranton Road, Suite 400 San Diego, CA 92121 Suresite Consulting Group, LLC, its employees and agents (collectively, "Suresite"), are authorized representatives of Alcatel-Lucent and have been contracted to perform real estate leasing, land use entitlements, architectural, and engineering services for development of and modification of SprintNextel communication facilities. As a representative of Alcatei-Lucent, Suresite is authorized to sign, submit, and review land-use applications and permits; provide representation at meetings and hearings; and negotiate leases on Alcatei-Lucent's behalf. All final land-use documents are subject to Alcatei-Lucent's review and approval. Furthermore, all leases, and any other legally binding documents, are contingent upon Alcatei-Lucent's review and the signature of a duly authorized Alcatei-Lucent manager. If there are any questions or comments, please contact me. Best Regards, ArtVos San Diego Market Manager 602-499-3340 '/ G -j' SureSite _______ _ lnfrastrncture Development Services Authorized Agent for Sprint Nextel and Alcatel Lucent Sprint Nextel Project Number: SD03XC183 Sprint Nextel Project Name: Olivenhain City of Carlsbad Minor Conditional Use Permit Application Project Information and Justification Sprint Nextel is requesting approval of a conditional use permit application to allow the maintenance, upgrading and continued operation of an unmanned wireless telecommunications facility on property already authorized for wireless telecommunication use (CUP 99-02) in the City of Carlsbad and presents the following project information for your consideration. Project Location Address: 1966 Olivenhain Road, Carlsbad, CA 92009 APN: 255-031-03-00 Zoning: Commercial Office Project Representative Name: SureSite Consulting Group, LLC Address: 20612 Kelvin Lane, Huntington Beach, CA 92646 Contact Information: Ed Gala, 714-709-1523, e.gala@sure-site.com Sprint Contact Name: Steve Layman Alcatel Lucent 9605 Scranton Road, Suite 400, San Diego, CA 92121 (619) 417-6295 steve.layman@alcatel-lucent.com Project Description Proposed is the removal of seven existing fayade mounted antennas and the reinstallation of one new 4G antenna per sector on the fayade of a mechanical equipment screen wall on the roof of a two story water district office building and the placement of one RRU unit per antenna behind the building parapet wall. The three replacement antennas will be concealed behind new box screen enclosures textured painted to match the building architectural columns. One existing radio equipment and battery cabinet (two cabinets total) will be removed and replaced with a new 4G equipment cabinet and new battery cabinet. The cabinets will be placed within an existing round mounted equipment enclosure. There will be a net reduction in the number of existing antennas on the subject building fayade from seven to three and a net reduction of six SureSite Consulting Group, LLC Corporate Office: 3659 Green Road, Suite 214 * Cleveland, OH 44122 * tel216-593-0400 * fax 216-593-0401 Western Region Office: 5955 DeSoto Avenue, Suite 142 *Woodland Hills, CA 91367 c '/ -j' SureSite _______ _ Infrastructure Development Services antennas from the original CUP entitlement for this property which authorized nine fac;ade mounted antennas. Project Objectives The proposed site maintenance and technology upgrade is intended to provide the residents of Carlsbad who are served by this facility, the latest in wireless technology by improving call quality, data transmission and speed. Alternative Site Analysis The following locations were evaluated for possible locations for the facility: NA. Proposed is the modification and maintenance upgrade to an existing Sprint installation Findings/Burden of Proof The project site is located in an established developed area. Office buildings have proved themselves to be ideal locations for wireless telecommunication facilities because the antenna use can easily be integrated into the operation of the office building, having no negative impact to the functioning of this land use or surrounding land uses. Wireless telecommunication is now an indispensable part of everyday life and wireless customers expect to be provided nearly flawless radio coverage at all locations and at all times. The subject project will provide improved radio coverage, improved data reception and transmission and improved data download speeds within the surrounding area to the benefit of the general health, safety, welfare and convenience of the public in the vicinity of this facility. The proposed project will reduce the number of antennas currently built on site and as such any visual impact that the existing antennas may have generated will be greatly reduced. In addition the three replacement antennas will be screened to match the building architecture. The proposed project is in conformance with all city General Plan goals by furthering the health, safety, welfare and convenience of city residents with the improvement and continued operation of a wireless telecommunication facility in an area of the city currently experiencing diminished wireless service. The proposed project is in conformance with all Federal Communications Commission (FCC) regulations and standards for wireless telecommunication facilities as documented in the attached FCC RF Certification form. All height, site and screening requirements have been met by this project. The installation is emergency 911 compatible with all wireless carriers. Sprint is authorized and regulated by the Federal Communications Commission (FCC) to operate their wireless systems in the Southern California market area. Transmit power is typically between 100 to 500 watts per antenna sector, transmitting and receiving at a frequency of 1850.0 -1865.0, and 1930.0-1945.0 MHz. These levels are well below the safety standards established by the FCC and no health impacts are anticipated with this project in conformance with city goals for telecommunication uses. In addition, Sprint does not oppose co-location on the subject building or project site and has left space for additional wireless carriers. This project design SureSite Consulting Group, LLC Corporate Office: 3659 Green Road, Suite 214 * Cleveland, OH 44122 * tel216-593-0400 * fax 216-593-0401 Western Region Office: 5955 DeSoto Avenue, Suite 142 *Woodland Hills, CA 91367 c 0 '/ -j' SureSite _______ _ Infrastructure Development Services will provide mitigation of future wireless development in the area by allowing for the concentration of additional facilities at one location, thereby minimizing the spread of these facilities throughout the community and providing mitigation of the potential visual impact in more view sensitive locations. The proposed facility will be unmanned requiring approximately one maintenance visit per month and will not have any significant impact to existing roadways and on and off site circulation nor have any impact on the character of existing development in the neighborhood Sprint Nextel Company Information Sprint Nextel is one of the fastest growing nationwide service providers offering all digital voice, messaging and high-speed data services to nearly 30 million customers in the United States. Sprint Nextel is a "telephone corporation", licensed by the Federal Communications Commission (FCC) to operate in the 1850.0 -1865.0, and 1930.0-1945.0 MHz frequencies, and a state- regulated Public Utility subject to the California Public Utilities Commission (CPUC). The CPUC has established that the term "telephone corporation" can be extended to wireless carriers, even though they transmit signals without the use of telephone lines. Sprint Nextel will continue to operate this facility in full compliance with the regulations and licensing requirements of the FCC, Federal Aviation Administration (FAA) and the CPUC, as governed by the Telecommunications Act of 1996, and subsequent modifications, the Middle Class Tax Relief and Job Creation Act of2012 (Section 6409) and other applicable laws. The enclosed application is presented for your consideration. Sprint Nextel requests a favorable determination and approval of a substantial conformance to modify its existing base station. Please contact me with any questions or requests for additional information. Respectfully submitted, Edward Gala Authorized Agent for Sprint Nextel and Alcatel Lucent SureSite Consulting Group, LLC Corporate Office: 3659 Green Road, Suite 214 * Cleveland, OH 44122 * tel216-593-0400 * fax 216-593-0401 Western Region Office: 5955 DeSoto Avenue, Suite 142 *Woodland Hills, CA 91367 Market San Diego cascadeiD SD03XC183 SECTOR 1 SECTOR 2 SECTOR 3 I~Pllt sector present NO NO NO 1900MHz_Azimuth 30 115 253 1900MHz_No_of Antennas 1 1 1 1900MHz_RADCenter(ft) 52.1 52.1 52.1 1900MHz_Antenna Make Powerwave RFS Powerwave 1900MHz_Antenna Model 7762.00-A APXVRR13-C-NA20 7762.00-A 1900MHz_Horizontal Beamwidth 93 67 93 1900MHz_Vertical Beamwidth 6.7 7 6.7 1900MHz_AntennaHeight (ft) 4.3 4.6 4.3 1900MHz_AntennaGain(dBd) 14.1 15.4 14.1 1900MHz_E Tilt 0 0 0 1900MHz _M_ Tilt 0 0 0 1900MHz_Carrier_ForecasLYear 2013 2 2 2 1900MHz_RRH Manufacturer ALU ALU ALU 1900MHz_RRH Model RRH 1900 4X45 65MHz RRH 1900 4X45 65MHz RRH 1900 4X45 65MHz 8 1900MHz_RRH Count 1 1 1 0\ 1900MHz_RRH Location Top of the Tower/Pole Top of the Tower/Pole Top of the Tower/Pole - 1900MHz Combiner Model No Combiner needed No Combiner needed No Combiner needed 1900MHz Top Jumper #1 Length (RRH or Combiner-to-Antenna, ft) 10 10 10 1900MHz_Top Jumper #1 Cable_Model (RRH or Combiner-to-Antenna) LCF12-50J LCF12-50J LCF12-50J 1900MHz Top Jumper #2 Length (RRH-to-Combiner, ft) N/A N/A N/A 1900MHz_Top Jumper #2_Cable Model (RRH-to-Combiner) N/A N/A N/A 1900MHz Main Coax_Cable Length (ft) N/A N/A N/A 1900MHz_Main Coax Cable_Model N/A N/A N/A 1900MHz_Bottom_Jumper #1_Length (Ground-based-RRH-OR_Combiner-to- Main-Coax, ft) N/A N/A N/A 1900MHz_Bottom_Jumper #1_Cable_Model (Ground-based-RRH- OR._Combiner-to-Main-Coax) N/A N/A N/A 1900MHz_Bottom Jumper #2 Length (Ground-based-Combiner-to-Main-N/A N/A N/A 1900MHz_Bottom_Jumper #2_Cable_Model (Ground-based-Combiner-to- Main-Coax) N/A N/A N/A SOOMHz_Azimuth N/A N/A N/A 800MHz No of_Antennas N/A N/A N/A SOOMHz RADCenter(ft) N/A N/A N/A SOOMHz AntennaMake N/A N/A N/A 800MHz_AntennaModel N/A N/A N/A 800MHz_Horizontal Beamwidth N/A N/A N/A SOOMHz Verticai_Beamwidth N/A N/A N/A SOOMHz_AntennaHeight (ft) N/A N/A N/A SOOMHz_AntennaGain (dBd) N/A N/A N/A 800MHz_E_ Tilt N/A N/A N/A 8 800MHz_M_ Tilt N/A N/A N/A 00 800MHz_RRH Manufacturer N/A N/A N/A 800MHz_RRH Model N/A N/A N/A 800MHz_RRH Count N/A N/A N/A 800MHz_RRH Location N/A N/A N/A SOOMHz_Top Jumper #1 Length (RRH or Combiner-to-Antenna, ft) N/A N/A N/A SOOMHz Top Jumper Cable Model (RRH or Combiner-to-Antenna) N/A N/A N/A SOOMHz_Main Coax_Cable Length (ft) N/A N/A N/A 800MHz_Main_Coax_Cable Model N/A N/A N/A 800MHz_Bottom_Jumper #1 Length (Ground-based-RRH-Main-Coax, ft) N/A N/A N/A SOOMHz_Bottom_Jumper #1_Cable_Model (Ground-based-RRH- OR_ Combiner-to-Main-Coax) N/A N/A N/A .. 5/2212012 c Ill 0 E E 0 0 u Alcatei·Lucent 6 DRAFT Product: 1900MHz RRH (65MHz) Product Description: This Remote Radio Head (RRH) supports the 1900MHz spectrum with a Quad Transmit and Quad Receiver configuration supporting 4x45W of output power in a dual head configuration Features I Benefits: Supports up to 6 carriers of CDMA in the 1900MHz spectrum and is hardware ready for 4x4 LTE MIMO (dual technology) Supports up to 8 carriers ofCDMA (single technology) Suppotts AISG -48V DC may be powered from Alcatei-Lucent cabinet Supports Hybriflex fiber I power cable bundle Technical Specifications: Physical Dimensions (HxWxD): 25" X 11.1" X 11.4" Weight: 60 pounds Output Power: 4x45W ( 180W Total) -··-Frequency Range: 1930-1995MHz Tx I 1850-1915 Rx Consumed Power (Typ): 680W Instantaneous Bandwidth: 65MHz Rx Noise fig_ure: _______ 3.0dB Antenna Interface : 7/16 DIN Female Operating Temperature Range: -40C to +55C Supports AISG 2.0 ---------·---------~----· ----·------------------------~ c 0 ._O......:....pt_im_i_ze_r®_S_id_e_-b_,y'--S_i_de_D_ua_I_P_o_la_ri_ze_d_A_n_t_en_n_a..:..., _17_1_0_-2_2_0-'0,'-6_5_d-'eg='-1_8_.0_d_Bi..:...., _1._3_m..:...., V_ET-',_0_-1_0_d_eg.:...... _ __.l a Product Descrrptror1 A combination of two X-Polarized antennas in a single radome, the RFS Quad- Pol antennas are designed for applications requiring a minimum number of antennas at a cell site and reduced tower loading. They offer the rugged construction of our new H Series of high band antennas that feature both high RF performance and energy efficiency. They are ideal for GSM1800, PCS, UMTS and Mobile TV networks where high gain is required. These antennas are especially well suited for.MIMO applications. Featu1 es;Bc llCftb •Two xoopolarlzecl broadband panels In a single radome -reduced tower loading •Rugged construction -high reliability •Superior gain tracking-difference between ULand DL <1dB •Stable azimuth horizontal bearnwidth -difference <&deg between UL and DL •Low PIM-no system down-time, high call quality and reduced number of dropped calls •Excellent upper sidelobe suppression -allows strong mechanical tilt •High gain -provides better coverage •Wldeband frequency performance -enables future growth and Increases flexibility •High front~ck ratio o()ptlonal remote tilt-can be retrofitted •AISG compatible remote tilt available -Add suffix -NA20 to the model number Tcciln1cal Specifications Electrical Specifications F!!Quency Ranae. MHz Horizontal Beamwidth, d!g Vertical Bellmwklth, d!g Eleetrical Downti!t. deg Gain, dBi (dBc:l) Upper Sidelobe Suppression, dB Front-To-Back Ratio, dB Polarization VSWR Isolation between Ports dB 3nl Order IMP «<! 2 x 43 dBm, dBc 7th Order IMP 0 2 x 38 dBm, dBc Impedance. Ohms Maximum Power Input, w Uqhtning Protection Connector Type 1710-1880 68 7.4 17.2 (15.1) 1850-1990 67 7 0-10 17.5 (15.4) > 18 (typically > 20) Typically 30 Dual pol +/-45' < 1.5:1 < 1.4:1 < 1.4:1 > 30 > 150, >150, NIA NIA, N/A, >170 50 300 Direct Ground (4) 7·16 Long Neck Female 1900-2200 65 6.5 18.0 (15.9) ·E Mechanical Specifications f Dimensions· HxWxD, mm (in) 1391 X 350 X 110 (54.6 X 13.8 X 4.3) VV!ight w/o Mta Hardware, ka Qb) Survivai'Mnd S!!!!d. kmlh (mph) Rated Vlllnd S!!!!d, kmlh Cmph) Max Vlllnd Loading Area, m' (It') Front Thrust A Rated \Nind, N (lbf) Maximum Thrust A Rated IMnd, N (lbf) Vlllnd Load. Side A Rated IMnd, N (lbf) S Vlllnd Load-Rear 0 Rated IMnd, N Qbfl i Radome Material ~ Radome Color .!! Mounting Hardware Material I Shipping Vl!!iaht. kp (!b) Packing Dimensions, HxWxD, mm (in) Ordering lnfonnatlon i Mounting Hardware 1 Mounting Pipe Diameter, mm (in) ~ Mounting Hardware Weight, kg (lb) .5 ~ APM40 Series Datasheet § APM40 Series Installation Instructions Other Doc LrrnenUt1on 14.5 (32.0) 200 (125) 160 (100) 0.49 (5.27) 640 (143.9) 640 (143.9) 147 (33.0) 491 (110.4) PVC Lillht Grey RAL7035 Diecasl8d Aluminum and Stainless Steel 22.5 (49.6) 1492x435 X 243 (58.7 X 17.1 X 9.6) APM40-2 60-120 (2.38-4.72) 3.4 (7.5) Vertical Pattern • t • ' I ~ ~ ~ I I ~~~~~~~~----~~~~----~~~~~~~~ ~~~R~F~S~T~h~e~C~I~e~ar~C~ho~i~c~e~®~~~---~A~P~XV~R~R~1~3~-C~----~------~---Pr_lm~oa~teF.:~03~.1mc1.~~5y1·1~ PleaH Yld ua on the 1m.met at b!!p·ttwww rflwprld cqml Radio Fntquency SyRen~s • c 7762.00-A Specifications ~ ...,., RADIO FREQUENCY SYSTEMS -=LWl FJW T h e C I e a r Choice'' 8 November 2011 7762.00 Dual High Broadband Cross Polarized POLARIZATION: XX-Pol FREQUENCY (MHz): 1710.2170 HORIZONTAL BEAM WIDTH('): 80 Frequency range (MHz) FNqllllt1ey blind (MHzl Gain {dBUdBd) ~ Nominal Impedance {0) VSWR Horizontal beam width, -3 dB (') Vel1ical beamwldlh,.-3dB (') Electrical down tiH (') Side lobe~. vel!k;al1at upper (dB) laolalion be'-! Inputs (dB) Tracking, horizontal plane :1:60' (dB) Fnt null. {dB) Vertical beam squint (') Front to bec:k.lll1io (dB) 180':1:30' c:opalar Front ID back ratio (dB) 180':1:30' IDtal power c-pa.,.~(XPO) 0" (dB) Crosa polar diacriminalion {XPD) :1:60' {dB) F.-field ccupllng 1M3, 2xTx@43dBm {dBc) IM7, 2xTX043dBftl(d8c) Power handNng, average per input (W) ~ - r,lll.HANILAL Sl'lCII ILA .IONs Connector Ccnnac:lar PQIIItlon Dimensions, HxWxD, mm (ft) Molllding Weight. with brackets, kg {lbs) w..,... .wfthout ...... kg (tilt) Wind la..t. -lide42 mls Cd•1.6 (N) Mllxilnwn opntionll wind epeed, mla (qlh) Survival wind speed, mla {mph) Lighlnlng praeectian Operating Temperature Radome nllllrill Radome colour ~-· HltWxD, mm (ft) Shipping weight, kg (lbs) RET Brackets 1710-1880 16.1/14.0 89 7.0 >17,17,16, 15. 14@0,2,4,6,8' >30 <2.0 >-25,typical>-18 <0.5 >24 >23 >17 >7 <-153 c-180 4 x 7/16 DIN Female lloiiDm 1320x343x100 {4'4'x1'1'x3') PAl-mounted heew duty brackets 23.5 {51.8) 18(39.6) 520 42(93) 55{123) DC~ -40'C 1D +60'C ASA Light Grey 1430x400x200 (4'8"x1'3'x7") 27.5 (60.6) 8110.40. 8110.10 7256.00, 7454.00 1710-2170 1850-1990 16.2/14.1 Dual linear :1:45' 50 <1.4:1 93 6.7 0-8 GAIN (dllildBd): 16.1/14.0.16.2114.1.16.5/14.4 TILT: G-6' LENGTH: 1.3m (4'3") 1920-2170 16.5/14.4 90 6.3 >17,17,16,15,14@0,2,4,6,8' >30 >20,18,17,16.15@0,2,4,6,8' >30 <2.0 >-25.typical>-18 <0.5 "25 >23 "17 >7 <-153 <-180 250 1000 i j__~ <2.0 >-25.typical>-18 <0.5 "26 >23 >12 >7 <-153 <-160 'All opec:ilicaliono IUbjocllo cl1ange wilhout nolico. Please c:antact ycur "'-Wave repesentative fer complete performlnce dll8. For deliiUed Plltlemll visit htlp:Jiwww.powerwave.com/rpa/. Radio Frequency Systems 200 Pondview Drive Meriden, CT 06450, USA Phone: (203) 630-3311 x1809 Fax: (203) 634-2155 www.rbworld com c OLIVENHAIN MUNICIPAL WATER DISTRICT 1966 Olivenhain Road Encinitas, CA 92024 (760) 753-6466 LETTER OF AUTHORIZATION 0 The Olivenhain Municipal Water District ("District") is the owner of the real property ("Property") described below, and hereby authorizes, consents, and agrees with Sprint PCS Assets, LLC, a Delaware Limited Liability Company, DBA SPRINT NEXTEL as follows: 1. .full:y. District consents and agrees that SPRINT NEXTEL, its employees, agents and independent contractors ("Authorized Parties") may enter upon the Property to conduct and perform some or all of the following activities ("Permitted Activities"): surveys, geotechnical soil borings and analysis, Phase I environmental audits, boundary surveys, radio propagation studies, and such other tests and inspections of the Property which SPRINT NEXTEL may deem necessary and advisable. SPRINT NEXTEL agrees to be responsible for any and all costs related to the Permitted Activities, including installation on and operation and removal of equipment on the Property. SPRINT NEXTEL also agrees to give a minimum of 48 hours notice in advance of performing any of the Permitted Activities at the site. 2. Filings. District consents and agrees that the Authorized Parties may make and file applications to such local, state and federal governmental entities whose approval SPRINT NEXTEL may consider necessary or advisable to have the Property approved as a tower or antenna site, including, but not limited to, governmental approvals for zoning variances, rezoning applications, building permits and wetland permits. District hereby agrees that a copy of this Agreement is as effective as the original. However, if requested by the Authorized Parties, District agrees to execute such other and further documents as may be required by the governmental entity in question to evidence District's consent to the action which is proposed to be taken. SPRINT NEXTEL understands and agrees that the District, in its sole discretion, may withdraw this Letter of Authorization at any time without cause. Property Address: 1966 Olivenhain Road, Encinitas, CA 92024 (99AGR043) Assessor's Parcel Number/Property Description: 255-031-03-00/0iivenhain Municipal Water District HQ Admin Parking Lot/SD03XC183 Olivenhain Municipal Water District By: ~~ f(S-. s4 Title: Engineering Manager TAX lO#: 95-6006689 Date: July 31,2012 George R. Driest rngineering Manager I l ' Main (760) 753-6466 Direct (760) 632-4640 Fax (760) 753-1578 gbriest@olivenhain.com OL~ ~ Municipal Water District 1966 Olivenhain Road Encinitas, CA 92024 . www.omwd.com CALIFORNIA ALL-PURPOSE CERTIFICATE OF ACKNOWLEDGMENT State of California County of ----=-~;;_;;.~~b==-l'""'etfL:Lllp"---- On JoiM \1 2012.-before me, ~tl\N ('AJ-'IidE"1 b>1AJM 11ltl,\C, .. _...,'-&.!+-,~---"'---='---(Here insert name and title of th~JC~ personally appeared ___ _,,K.!fOe(b"-===-=---.:'a:.......::... _ _.1,.....,2.=\ ...... ~.....,._Cf"-----------------' who proved to me on the basis of satisfactory evidence to be the person(J1 whose name¢) is/~ subscribed to the within instrument and acknowledged to me that he/s~e/t~ey executed the same in hislhJr/thq1r authorized capacity(i{s ), and that by hi~r/thiir signature~) on the instrument the person(J1, or the entity upon behalf of which the person~ acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. DESCRIPTION OF THE ATTACHED DOCUMENT (Title or description of attached document) (Title or description of attached document continued) Number of Pages __ Document Date ____ _ (Additional information) CAPACITY CLAIMED BY THE SIGNER 0 Individual (s) 0 Corporate Officer (Title) 0 Partner(s) 0 Attorney-in-Fact 0 Trustee(s) 0 exher ____________________ _ (Notary Seal) OPTIONAL INFORMATION INSTRUCTIONS FOR COMPLETING THIS FORM Any acknowledgment completed in California must contain verbiage exactly as appears above in the notary section or a separate acknowledgment form must be properly completed and attached to that document. The only exception is if a document is to be recorded outside of California. In such instances, any alternative acknowledgment verbiage as may be printed on such a document so long as the verbiage does not require the notary to do something that is illegal for a notary in California (i.e. certifying the authori=ed capacity of the signer). Please check the document carefully for proper notarial wording and attach this form if required. • State and County information must be the State and County where the document signet(s) personally appeared before the notary public for acknowledgment. • Date of notarization must be the date that the signer(s) personally appeared which must also be the same date the acknowledgment is completed. • The notary public must print his or her name as it appears within his or her commission followed by a comma and then your title (notary public). • Print the name(s) of document signer(s) who personally appear at the time of notarization. • Indicate the correct singular or plural forms by crossing off incorrect forms (i.e. l!elsheMey, is !&Ee ) or circling the correct forms. Failure to correctly indicate this information may lead to rejection of document recording. • The notary seal impression must be clear and photographically reproducible. Impression must not cover text or lines. If seal impression smudges, re-seal if a sufficient area permits, otherwise complete a different a~owledgment form. • Signature of the notary public must match the signature on file with the office of the county clerk. <• Additional information is not required but could help to ensure this acknowledgment is not misused or attached to a different document. <-Indicate title or type of attached document, number of pages and date. + Indicate the capacity claimed by the signer. If the claimed capacity is a corporate offJCet, indicate the title (i.e. CEO, CFO, Secretary). • Securely attach this document to the signed document 2008 Version CAPA vl2.10.07 800-873-9865 www.NotaryCiasses.com , City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 1111~11111111111111!11111111111111111~1111111111111111!1111 Applicant: SPRINT NEXTEL Description Amount MCUP1203 714.90 1966 OLIVENHAIN RD CBAD Receipt Number: R0090620 Transaction ID: R0090620 Transaction Date: 08/03/2012 Pay Type Method Description Amount Payment Check 714.90 Transaction Amount: 714.90 City of Carlsbad Faraday Center Faraday Cashiering 001 1221601-1 08/03/2012 34 Fri, Aug 03, 2012 11:12 AM Receipt Ref Nbr: R1221601-1/0021 PERMITS -PERMITS Tran Ref Nbr: 122160101 0021 0024 Trans/Rcpt#: Rll090620 SET #: MCUP1203 Amount: Item Subtota 1 : Item Tot a 1: ITEM(S) TOTAL: Check (Chk# 0889) Cash Total Received: CHANGE: we a nice day! 1 @ $714.90 $714.90 $714.90 $714.90 $705.00 $10.00 $715.00 $0' 10 .... , 0 0 FILE COPY /0. :3·/CJ (t~ CITY OF ¥CARLSBAD Community & Economic Development www.carlsbadca.gov NOTICE OF REQUEST FOR A MINOR CONDITIONAL USE PERMIT Notice is hereby given that a Minor Conditional Use Permit (MCUP) has been applied for to allow the continued operation of a Wireless Communication Facility on property generally located at, 1966 Olivenhain Road, Carlsbad, California, and more particularly described as: Portion of lot 10 of the subdivision of the Rancho Los Encinitas in the County of San Diego, according to Map No. 843, filed June 27, 1896. If you have any objections to the granting of this MCUP or wish to have an informal hearing to discuss the requested MCUP, please notify the Planning Division, 1635 Faraday Avenue, Carlsbad, California 92008, in writing within 1 0 days of the date of this notice. If you have any questions, please call Austin Silva in the Planning Division at (760) 602-4631. CASE NO.: MCUP 12-03 CASE NAME: Olivenhain PCS DATE: October 3, 2012 CITY OF CARLSBAD PLANNING DIVISION · · · ·: Planning Division ~~-~--~---------------------------------------------------.:1:: · 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 ------------~-~-----~~·····~-·- 75 65 ® CITY OF CARLS:'BAD II 2. .. ,, ~·:.·.~20' TRAIL ESMT 30 ... . . . . @ 15.14 AC fOR BRG PG 300' RADIUS MAP GC MAPPING SERVICE INC 3055 WEST VALLEY BOULEVARD ALHAMBRA CA 91801 OFF (626) 441-1080, FAX (626) 441-8850 gcmapping@radiusmaps.com LEGEND 2. OWNERSHIP NO. t OWNERSHIP HOOK CASE NO. DATE: 05-31-2012 SCALE: 1' = 1 00' OWNERSHIP MAP I HEREBY CERTIFY THAT THE PROPERTY OWNERS LIST AND LABELS SUBMITTED TO THE CITY OF CARLSBAD ON THIS DATE REPRESENT THE LATEST AVAILABLE iNFORMATION FROM THE EQUALIZED ASSESSOR'S ROLES. APPLICATION NAME AND NUMBER l1lp(p OL i Vb +tA; l\J R-J · CANT'S REPRESENTATIVE BY: . Cut-LJ/(t DATE: tQ~'i 3\ ,l,DIL RECEIVED BY DATE:----------- CITY OF CARLSBAD REVIEW AND COMMENT MEMO DATE: AUGUST 3, 2012 PROJECT NO(S): _M~C-=-U.:....P--=1=-2---=-0-=-3 ____________ REVIEW NO: _1 __ ---1 PROJECT TITLE: OLIVENHAIN PCS SD03XC183 APPLICANT: SURE SITE ----------------------------------------------------~ TO: [8J Land Development Engineering 0 Police Department-J. Sa sway [8J Fire Department-Greg Ryan 0 Building Department-Will Foss 0 Recreation -Mark Steyaert 0 Public Works Department {Streets)-Nick Roque 0 Water/Sewer District 0 Landscape Plancheck Consultant-PELA 0 School District 0 North County Transit District-Planning Department 0 Sempra Energy-Land Management 0 Caltrans {Send anything adjacent to 1-5) 0 Parks/Trails -liz Ketabian *ALWAYS SEND EXHIBITS FROM: PLANNING DEPARTMENT Please review and submit written comments and/or conditions to the PLANNING TRACKING DESK in the Planning Department at 1635 Faraday Avenue, by 08/24/2012. If you have "No Comments," please so state. If you determine that there are items that need to be submitted to deem the application "complete" for processing, please immediately contact the applicant and/or their representatives (via phone or e-mail) to let them know. Signature Date PLANS ATTACHED Review & Comment 05/11 CARLSBAD FIRE DEPARTMENT FIRE PREVENTION BUREAU Discretionary Review Checklist PROJECT NUMBER: MCUP 12-03 ------------------------------------------------------------ BUILDING ADDRESS: 1966 Olivenhain ~~~--~~------------------------------------------------ PROJECT DESCRIPTION: Modify existing unmanned telecommunication facility ASSESSOR'S PARCEL NUMBER: FIRE DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. By: D. Fieri Date: 8-27-12 ATTACHMENTS COMMENTS DENIAL Please see the attached report of deficiencies marked with . Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: ---------------Date: By: ---------------Date: By: ---------------Date: FIRE DEPARTMENT CONTACT PERSON NAME: ADDRESS: 1635 Faraday Ave Carlsbad, CA 92008 PHONE: (760) 602-4665 Fire Department has reviewed this project as requested and has no comments and/or conditions to submit. ** A comprehensive Plan Check will be completed prior to permit issuance and additional technical code requirements may be identified and changes to this submittal and comments based upon this submittal may be required. D. Fieri «~~ CITY 0 F ~'CARLSBAD Memorandum August 7, 2012 To: Austin Silva, Project Planner From: David Rick, Project Engineer Via: Glen Van Peski, Senior Civil Engineer Re: SUBJECT: MCUP 12-03 OLIVENHAIN PCS SD03XC183 CONDITIONS 0 Land Development Engineering has completed its review of the above referenced project for application completeness and has determined that the application and plans submitted for this project are complete and suitable for continued review. Engineering staff does not have any comments to add to the project. Please add the following conditions to the approving resolution/letter: 1. Developer shall comply with the City's Stormwater Regulations, latest version, and shall implement best management practices at all times. Best management practices include but are not limited to pollution treatment practices or devices, erosion control to prevent silt runoff during construction, general housekeeping practices, pollution prevention and educational practices, maintenance procedures, and other management practices or devices to prevent or reduce the discharge of pollutants to stormwater, receiving water or stormwater conveyance system to the maximum extent practicable. Developer shall notify prospective owners and tenants of the above requirements. If you or the applicant has any questions regarding the above, please either see or call me at extension 2781. David Rick Associate Engineer-Land Development Engineering ~ ~ Community & Economic Development 1635 Faraday Ave. I Carlsbad, CA 92008 I 760-602-2710 I 760-602-8560 fax I www.carlsbadca.gov CITY OF CARLSBAD REVIEW AND COMMENT MEMO DATE: AUGUST 3, 2012 PROJECT NO(S): MCUP 12-03 REVIEW NO: 1 -----------------------------------------~ PROJECT TITLE: OLIVENHAIN PCS SD03XC183 APPLICANT: SURE SITE ~~~~--------------------------------------------~ TO: [8J Land Development Engineering D Police Department-J. Sasway [8J Fire Department-Greg Ryan D Building Department-Will Foss D Recreation -Mark Steyaert D Public Works Department (Streets)-Nick Roque D Water/Sewer District D Landscape Plancheck Consultant-PELA D School District D North County Transit District-Planning Department D Sempra Energy-Land Management D Caltrans (Send anything adjacent to I-'S) D Parks/Trails-Liz Ketabian *ALWAYS SEND EXHIBITS FROM: PLANNING DEPARTMENT Please review and submit written comments and/or conditions to the PLANNING TRACKING DESK in the Planning Department at 1635 Faraday Avenue, by 08/24/2012. If you have "No Comments," please so state. If you determine that there are items that need to be submitted to deem the application "complete" for processing, please immediately contact the applicant and/or their representatives (via phone or e-mail) to let them know. Thank you COMMENTS:·----------------------------------------------------- Signature Date PLANS ATTACHED Review & Comment 05/11 Planning Division October 16, 2012 Sure Site Attn: Ed Gala 20612 Kelvin lane Huntington Beach, CA 92646 ~ W\\uhtz- F\LE COPY www.carlsbadca.gov SUBJECT: MINOR CONDITIONAL USE PERMIT NO. MCUP 12-03 -OLIVENHAIN PCS SD03XC183 - Request for approval of a Minor Conditional Use Permit (MCUP 12-03; replaces CUP 99-02X1) to allow for the modification to an existing WCF (removal of seven existing fa~ade mounted antennas and the installation of 3 new 4G antennas on the fa~ade which are concealed behind new box screen enclosures textured and painted to match the building's architectural columns) at 1966 Olivenhain Road, in the Office (0) Zone and local Facilities Management Zone 11. Dear Mr. Gala, The City Planner has completed a review of your application for a Minor Conditional Use Permit 12-03 for the modification to an existing wireless communication facility at 1966 Olivenhain Road. A notice was sent to property owners within a 300' radius of the subject property requesting comments regarding the above request. No <:omments were received within the ten day notice period (ending on October 12, 2012). After careful consideration of the circumstances surrounding this request, the City Planner has determined that the four findings required for granting a Minor Conditional Use Permit can be made and therefore, APPROVES this request based on the following findings and conditions. Findings: 1. That the requested use is necessary or desirable for the development of the community, and is in harmony with the various elements and objectives of the general plan, including, if applicable, the certified local coastal program, specific plan or master plan in that (a) the use is necessary and desirable for the development of the community because of the benefit and demand for digital communication and data transmissions for businesses, individuals, public agencies and emergency service systems in this part of the city; (b) the proposed use is consistent with the General Plan in that the Government Facilities (G) Land Use designation does not preclude the provision of Wireless Communication Facility (WCF) use. The proposed WCF is consistent with City Council Policy No. 64, (Office Zone) and has a stealth design. The project's location and stealth design comply with General Plan objectives that seek to maintain and enhance Carlsbad's appearance. 2. That the requested use is not detrimental to existing uses or to uses specifically permitted in the zone in which the proposed use is to be located in that the WCF is located in a preferred location (Office Zone) as listed in Location Guideline A.l.c of City Council Policy Statement No. 64, and all aspects of the WCF exhibit stealth design as the replacement antennas are concealed behind box screen enclosures that will be textured and painted to match the existing building. The WCF use is not precluded by the project site's Office (O) Zone. Furthermore, the modification to the WCF will 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602--8559 ,.... """"""' MCUP 12-03-OLIVENHAIN PCS SD03XC183 October 16, 2012 Page 2 not result in any additional building coverage,. does not visually impact the existing site or building design as the box screen enclosures are designed so that they blend in with the building architecture. The project has been conditioned to comply with FCC RF Exposure Guidelines. 3. That the site for the proposed conditional use is adequate in size and shape to accommodate the yards, setbacks, walls, fences, parking, loading facilities, buffer areas, landscaping and other development features prescribed in this code and required by the City Planner in order to integrate the use with other uses in the neighborhood in that all of the proposed replacement antennas are mounted behind box screen enclosures and the equipment is located in an existing enclosure outside the building. The minor modifications (removal of seven existing fa~ade mounted antennas and the installation of 3 new 4G antennas on the fa~ade which are concealed behind new box screen enclosures textured and painted to match the building's architectural columns) will not impact the appearance of the building as the RF panel screens are designed to blend in with the existing building texture and color. 4. That the street system serving the proposed use is adequate to properly handle all traffic generated by the proposed use in that the modified WCF requires, on average, one monthly maintenance visit and occasional visits in response to operational problems. 5. That the existing and proposed WCF is consistent with City Council Policy No. 64 in that it is located in a preferred location (Office Zone) as listed in location Guideline A.1.c of City Council Policy Statement No. 64 and exhibits stealth design, as the three replacement antennas are mounted behind box screen enclosures textured and painted to match the building thereby exhibiting stealth d~sign techniques. The equipment is located in an existing enclosure outside the building that is textured and painted to match the existing building. 6. That the City Planner has determined that the project belongs to a class of projects that the State Secretary for Resources has found do not have a significant impact on the environment; and it is therefore categorically exempt from the requirement for the preparation of environmental documents pursuant to Section 15301 -(Existing Facilities), of the state CEQA Guidelines. Additionally, as AT&T Mobility must comply with FCC regulations, radio frequency emissions from the proposed facility are below levels established as acceptable by the FCC, and are therefore not considered a health hazard. In making this determination, the City Planner has found that the exceptions listed in Section 15300.2 of the state CEQA Guidelines do not apply to this project. 7. The City Planner has reviewed each of the exactions imposed on the Developer contained in this resolution, hereby finds, in this case that the exactions are imposed to mitigate,the impacts caused by or reasonably related to the project, and the extent and the degree of the exaction is in rough proportionality to the impact caused by the project. Conditions: 1. Approval is granted for MCUP 12-03 as shown on Exhibits "A-J'' dated October 16, 2012 on file in the Planning Division and incorporated herein by reference. Development shall occur substantially as shown unless otherwise noted in these conditions. 2. If any of the following conditions fail to occur, or if they are, by their terms, to be implemented and maintained over time, if any of such conditions fail to be so implemented and maintained according to their terms, the City shall have the right to revoke or modify all approvals herein granted; deny or further condition issuance of all future building permits; deny, revoke, or further condition all . '· .. "'-"' MCUP 12-03-OLIVENHAIN PCS SD03XC183 October 16, 2012 Page 3 certificates of occupancy issued under the authority of approvals herein granted; record a notice of violation on the property title; institute and prosecute litigation to compel their compliance with said conditions or seek damages for their violation. No vested rights are gained by Developer or a successor in interest by the City's approval of this Minor Conditional Use Permit. 3. Staff is authorized and directed to make, or require the Developer to make, all corrections and modifications to the MCUP 12-03 documents, as necessary to make them internally consistent and in conformity with the final action on the project. Development shall occur substantially as shown on the approved Exhibits. Any proposed development different from this approval shall require an amendment to this approval. 4. The Developer/Operator shall and does hereby agree to indemnify, protect, defend and hold harmless the City of Carlsbad, its Council members, officers, employees, agents, and representatives, from and against any and all liabilities, losses, damages, demands, claims and costs, including court costs and attorney's fees incurred by the City arising, directly or indirectly, from (a) City's approval and issuance of this Minor Conditional Use Permit, (b) City's approval or issuance of any permit or action, whether discretionary or non-discretionary, in connection with the use contemplated herein, and (c) Developer/Operator's installation and operation of the facility permitted hereby, including without limitation, any and all liabilities arising from the emission by the facility of electromagnetic fields or other energy waves or emissions. 5. The Developer shall comply with all applicable provisions of federal, state, and local ordinances in effect at the time of building permit issuance. 6. This project shall comply with all conditions and mitigation measures, which are required as part of the Zone 11 Local Facilities Management Plan and any amendments made to that Plan prior to the issuance of building permits. 7. MCUP 12-03 shall be reviewed by the City Planner on a yearly basis to determine if all conditions of this permit have been met and that the use does not have a substantial negative effect on surrounding properties or the public health, safety and general welfare. If the City Planner determines that: 1) the minor conditional use permit was obtained by fraud or misrepresentation; or 2) the use for which such approval is granted is not being exercised; or 3) the conditions of approval have not been met; or 4) the minor conditional use permit is being or recently has been exercised contrary to any of the terms or conditions of approval; or 5) the use for which such approval was granted has ceased to exist or has been suspended for one year or more; or 6) the use is in violation of any statute, ordinance, law or regulation; or 7) the use permitted by the minor conditional use permit is being or has been so exercised as to be detrimental to the public health, safety or welfare or so as to constitute a nuisance, the City Planner shall hold an informal public hearing and after providing the permittee the opportunity to be heard, the City Planner may revoke and terminate the minor conditional use permit in whole or in part, reaffirm the minor conditional use permit, modify the conditions or impose new conditions. 8. This Conditional Use Permit is granted for a period of 10 years from October 16, 2012 through October 16, 2022. This permit may be revoked at any time after a public hearing, if it is found that the use has a substantial detrimental effect on surrounding land uses and the public's health and welfare, or the conditions imposed herein have not been met. This permit may be extended for a reasonable period of time not to exceed ten (10) years upon written application of the permittee made no less than 90 days prior to the expiration date. The Planning Commission may not grant such extension, unless it finds that there are no substantial negative effects on surrounding land uses -MCUP 12-03-OLIVENHAIN PCS SD03XC183 October 16, 2012 Page 4 or the public's health and welfare. If a substantial negative effect on surrounding land uses or the public's health and welfare is found, the extension shall be denied or granted with conditions which will eliminate or substantially reduce such effects. There is no limit to the number of extensions the Planning Commission may grant. 9. Prior to the issuance of a building permit, owner/applicant shall submit to the City a Notice of Restriction to be filed in the office of the County Recorder, subject to the satisfaction of the City Planner, notifying all interested parties and successors in interest that the City of Carlsbad has issued a Minor Conditional Use Permit on the real property owned by the owner/applicant. Said Notice of Restriction shall note the property description, location of the file containing complete project details and all conditions of approval as well as any conditions or restrictions specified for inclusion in the Notice of Restriction. The City Planner has the authority to execute and record an amendment to the notice, which modifies or terminates said notice upon a showing of good cause by the owner/applicant or successor in interest. 10. Developer shall report, in writing, to the City Planner within 30 days, any address change from that which is shown on the permit application. 11. Developer/Operator shall comply with the Federal Communication Commission's guidelines on limits for human exposure to radio frequency (RF) electromagnetic fields. Within six (6) months after the issuance of occupancy, and with any time extension or amendment request, the Developer/Operator shall submit to the City Planner either (1) verification that the project is categorically excluded from having to determine compliance with the RF exposure guidelines per 47 CFR §1.1307(b)(1); or (2) a project implementation report which provides cumulative field measurements of RF emissions of all antennas installed at the subject site. The report shall quantify the RF emissions and compare the results with the exposure limits established by the FCC guidelines. Said report shall be subject to review and approval by the City Planner for consistency with the Project's preliminary report on RF exposure submitted with the initial project application and for consistency with the FCC guidelines. If, on review, the City finds that the Project does not meet the FCC guidelines, the City may revoke or modify this conditional use permit. Engineering: 12. Developer shall comply with the City's Stormwater Regulations, latest version, and shall implement best management practices at all times. Best management practices include but are not limited to pollution control practices or devices, erosion control to prevent silt runoff during construction, general housekeeping practices, pollution prevention and educational practices, maintenance procedures, and other management practices or devices to prevent or reduce the discharge of pollutants to stormwater, receiving water or stormwater conveyance system to the maximum extent practicable. Developer shall notify prospective owners and tenants of the above requirements. Code Reminders: 13. Approval of this request shall not excuse compliance with all applicable sections of the Zoning Ordinance and all other applicable· City ordinances in effect at time of building permit issuance, except as otherwise specifically provided herein. 14. Premise identification (addresses) shall be provided consistent with Carlsbad Municipal Code Section 18.04.320. '-" MCUP 12-03-OLIVENHAIN PCS SD03XC183 October 16, 2012 Page 5 NOTICE Please take NOTICE that approval of your project includes the "imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to for convenience as "fees/exactions." You have 90 days from the date of final approval to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedure set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity charges, nor planning, zoning, grading or other similar application processing or service fees in connection with this project; NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. This decision may be appealed by you or any other member of the public to the Planning Commission within ten days of the date of this letter. Appeals must be submitted in writing to the Planning Division at 1635 Faraday Avenue in Carlsbad, along with a payment of $638.00 (plus noticing costs). The filing of such appeal within such time limit shall stay the effective date of the order of the City Planner until such time as a final decision on the appeal is reached. If you have any questions regarding this matter, please feel free to contact Austin Silva at (760) 602-4631. Sincerely, CHRIS DeCERBO Principal Planner CD:AS:bd c: Sprint Nextel, 9605 Scranton Rd. #400, San Diego, CA 92121 Olivenhain Municipal Water District, 1966 Olivenhain Rd., Carlsbad, CA 92024 Don Neu, City Planner Michele Masterson, Senior Management Analyst Principal Planner Project Engineer File Copy OMS/Data Entry _,Jf~.A._ C I T Y 0 F VcARLSBAD Planning Division August 21, 2012 Sure Site Attn: Ed Gala 20612 Kelvin Lane Huntington Beach, CA 92646 SUBJECT: 1st REVIEW FOR MCUP 12-03-OLIVENHAIN PCS SD03XC183 www.carlsbadca.gov Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning Division has reviewed your Minor Conditional Use Permit, application no. MCUP 12-03, as to its completeness for processing. The application is complete, as submitted. Although the initial processing of your application may have already begun, the technical acceptance date is acknowledged by the date of this communication. The City may, in the course of processing the application, request that you clarify, amplify, correct, or otherwise supplement the basic information required for the application. In addition, you should also be aware that various design issues may exist. These issues must be addressed before this application can be scheduled for a hearing. The Planning Division will begin processing your application as of the date of this communication. In order to expedite the processing of your application, you are strongly encouraged to contact your Staff Planner, Austin Silva, at (760) 602-4631, to discuss or to schedule a meeting to discuss your application and to completely understand this letter. You may also contact each commenting department individually as follows: • Land Development Engineering Division: David Rick, Associate Engineer, at (760) 602-2781. • Fire Department: Greg Ryan, Fire Inspections, at (760) 602-4661. Sincerely, CHRIS DeCERBO Principal Planner CD:AS:bd c: Olivenhain Municipal Water District, 1966 Olivenhain Road, Encinitas, CA 92024 Don Neu, City Planner David Rick, Project Engineer Chris DeCerbo, Principal Planner File Copy Data Entry 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 MCUP 12-03-OUVENHAIN PCS SD03XC183 August 21, 2012 Page 2 ISSUES OF CONCERN Planning: 1. Please either remove the existing Sprint pipe mounts, or install stealth antenna boxes to screen the pipe mounts.