RELOCATION CORRECTION LIST
RLRMITTEE: . Jose Rico _ ADDRESS: 910 Vyoodlake Drive RHONE
BUILDING LOCATION: 2815 Jefferson PROPOSED LOCATION: 3171 Jefferson
Carlsbad Carlsbad
This is a copy of the corrections and work to be accomplished to the building you have
proposed to relocate. It will serve to inform you of the required work to be done before
said building can be occupied at the new address. These corrections are the terms and
conditions of the Relocation Permit, and are required to be completed within 1^0 days
from the date the permit is issued.
NOTE: This is not a petMTiit. Do not move the building or start any work until you
have posted the required bond, obtained the Relocation Permit and Planning Commission
approval. ITEMS CHECKED ARE YOUR CORRECTIONS.
BUILDING:
X 3
N/A 4
N/A 5
Provide two(2) copies
foundation and pro-
posed site plans.
Provide underfloor ventilation,
access and clearance as per code.
Underfloor structure to be altered
meet Code requirements as follows:
Continuous foundation with
3dequate_spaced^^p^^^
approved girder span
Replace existing roof covering with
fire retardant material.
Ceiling joists, rafters and other
structural members to be altered
to meet code as follows:
N/A 6 Exterior surfaces to be repaired,
painted, restuccoed, or otho'wise
corrected as follows to provide
adequate weather protection:
N/A 7
•X 8
Reroofing
weather "
required to provide
protection. weather protection.
All broken doors, windows and
screens to be repaired, replaced,
and/or repainted as required.
Fireplace, chimney and/or other
masonry units to be corrected ^
fol lows:
as
N/A 10 One hour fire resistive construc-
tion to be provided
N/All Repair or replace floors, walls
and/or ceilings to match existing
as follows:
N/A 12 Inadequate room size in
NXA_13 Inadequate ceiling height in
N_/_A 14 Inadecjuate l iglit and vefiti I a t ion
in
N/A..^5 Provide access to attic.
N/_A_J6 Correct dampness in
X 17 Provide landings and/or steps as
fol 1 ows : front and rear entrys
PLUMBING
X 18
N/A 19
20
'21
Separate plumbing and sewer permits
requi red.
All abandoned sewers, cesspools,
and septic tanks to be filled and/
or capped.
Connect house drain to sewer.
Drain and vent lines to be altered
to meet code as follows: cast
j.roO^ to be replaced_wj.th. A, B ,.S. .
X 22
X 23
Install backfiow device on all hose
bibs.
24
25
26
Provide water test on drainage and
vent system to roof.
Water lines to be corrected as
fol 1 ows : Remove galvanized water .
pipe and re place with a ppr ov e_d
copper tubing
Following plumbing fixFureCsl to
be corrected as rioted:JKJJ^chen__
sink waterlines and drains
X 27
X
X
28
"29
Repair shower compartiiioiit to \)V0"
vido water|)roofing.
Correct gas system as follows: Jo
accommodate. in5talJation_-of heating
units _
Iprovide gas test.
Heating corrections to be made as
fol 1 ows : Replace flopr_furnace with
apprqyedLfprced air or wall unit
30 Provide new water heater or correct
existing unit as follows: