HomeMy WebLinkAboutPIP 93-01; Republic Tool & Manufacturing Bldg. No. 2; Planned Industrial Permit (PIP) (14)March 11,1993
Republic Tool
Am: Mike Ramsey
6212 Corte del Abeto Carlsbad, CA 92009
SU'RJECX PR 93-07 - REPUBLIC TOOL AND MANUFACX"NG BUILDING %2
APN: 213461-02
Preliminary review of your project was conducted on March 11, 1993. Listed below are the issues
raised by staff. Please note that the purpose of a preliminary review is to provide you with
direction and comments on the overall concept of your project. The DTC~UMIV revl 'ew does not raresent an indmth anahis of vow miect Additional issues of concem mav be raised aft= vow
mlication is submitted and ~rocessed for a more dc and detailed review.
..
1. Because the proposed building is located in the PM Zone, a planned industrial permit will
need to be processed prior to application for building permit. Application materials for the
permit are located at the front counter of the planning department. Refer to Chapter 21.34
of the Zoning Ordinance regarding standards.
2. 4,815 square feet of outdoor eating area is needed. Rder to Zoning code section
21.34.070(3) and Administrative Policy No. 19 for pertinent regulations. The southwest
comer of the lot appears to be the best location for the eating area.
3. The architecture of the building facing the cul-de-sac needs improvement. PossLbilities
include using various textures, adding more windows, and recessing the building to
eliminate the "boxy" appearance.
4. Visibility of the loading bays on the north elevation from Palomar Airport Road and the lots
on the north side of Palomar Airport Road.is a concern. Additional landscaping and/or a
decorative wall will need to be added in order to screen the bays. In your PIP application,
provide a cross section of the property from the north side of Palomar Airport Road -to the
proposed building to indicate the buildings visibility from the road.
5. Relocate the trash dumpster so that it is less visible from Corte Del Abeto.
6. A minimum of 10 percent of the lot inclusive of driveways but exclusive of required building setbacks needs to be landscaped.
7. Additional drainage slopes are needed (1% instead of .5%).
8. The driveway (off Corte Del Abeto and adjacent lot) should be designed with vexticle cur~e~ at 36' maximum width.
2075 Las Palmas Drive - Carlsbad. California 92009-1 576 (61 9) 438-1 161
A
Republic Tool
Am: Mike Ramsey March 11,1993
Pane 2
9. The driveway to the adjoining lot appears to be extremely steep (approximately 20% by our
estimate). A redesign there is recommended or show sufficient detail indicating a lesser
slope.
Please contact me at (619) 438-1161, extension 4328 if you have any questions.
Sincerely,
DAWD RICK Planning Technician
DRlh
c: File Copy
Adrienne Landers Tem Woods