HomeMy WebLinkAboutPIP 94-01; Innovative Time; Planned Industrial Permit (PIP) (6)October 21, 1993 6 S H A Design Group, Inc. Bill Bocken 919 Fourth Avenue, Suite 200 San Diego CA 921 01 SUBJECT: INNOVATIVE TIME - PRE 93-29 APN: 212-092-23 Preliminary review of your project was conducted on 10-13-93. Listed below are the issues raised by staff. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. The preliminary review does not represent an in-depth analvsis of your proiect. Additional issues of concern mav be raised after vour application is submitted and processed for a more specific and detailed review. Overall, The project is of good design and meets or exceeds the requirements of Specific Plan 181 (A). The project does not have any major design issues that would keep the Planned Industrial Permit from being approved. What follows are a few minor items that should be addresses prior to the submittal for a Planned Industrial Permit. 1. 2. 3. 4. 5. 6. The parking figures should be rounded up to the next highest whole number, and the truck loading area does not qualify as a parking space. Provide handicap parking at a ratio of 1 space per 40 parking spaces and label location on plans. The parking space exterior of the security gate should be eliminated or redesigned as not to conflict with cars backing out of the space. Drive isles shall maintain a minimum width of 24 feet. The parking as stated is at the minimum requirement for the building. Any future conversions of floor area to a more intensive use (i.e. warehouse to office or manufacturing) will require additional parking. Show treatment for outdoor eating area (i.e. turf/hardscape, furniture, etc.) 2075 Las Palmas Drive - Carlsbad, California 92009-1 576 - (61 9) 438-1 161 @ B S H A Design Group, Inc. October 21, 1993 Paae 2 7. Provide topographic information on the site plan or if the submittal includes grading plans, the grading plans will be sufficient. There was a question raised regarding fencing for the site. Fencing is allowed but the materials used should be wrought iron or of a similar material and of open design. Chain link fencing is not acceptable. Any screen wails for storage areas should be masonry walls, such as for trash enclosures. Please find attached a red-lined check print for your review. Please contact Van Lynch af (61 9) 438-1 161, extension 4325 if you have any questions. ,7 Assistant Planning Director GEW:VL:lh PRE9329.VL attachment C: Bobbie Hoder File Copy Data Entry Ken Quon