Loading...
HomeMy WebLinkAboutPIP 95-10; Carlsbad Airport Centre Lot 48; Planned Industrial Permit (PIP) (3)September 7, 1995 TO: VAN LYNCH, PLANNING TECHNICIAN II FROM: Associate Engineer VIA: Principal Civil Engineer /t fl LOT 48 CARLSBAD AIRPORT INDUSTRIAL, PRE 95-30 We offer the following comments: 1. Truck turning radii should be plotted on the site plan to indicate that adequate space is provided for a 60’ turning radius, in accordance with Caltrans Highway Design Manual, Figure 407D. 2. The width of the parking lot aisle proposed for the north side of the site should be a minimum of 32’, as it also serves as a parking area for the two loading doors. For those parking lot aisles that serve parking stalls on one or both sides, the minimum required aisle width is 24’. 3. Please note that this project is be subject to the City’s requirements of the National Pollutant Discharge Elimination System (NPDES) permit. This permit requires a project to provide best management practices to reduce surface pollutants to an acceptable level prior to discharge. The site plans or grading plans should indicate how this requirement will be met. Other industrial projects have utilized methods such as directing runoff from paved parking areas towards a landscaped swale prior to reaching the storm drain; or installing a drainage inlet which has been modified to remove pollutants prior to discharge into the storm drain. Attached is a red lined check print. If you have any questions regarding the comments above, please contact me at extension 4380. KENNETH W. QUON Associate Engineer