HomeMy WebLinkAboutPIP 95-11; P.E.D.I.; Planned Industrial Permit (PIP) (7)Ken Smith Architect and Associates, Inc. 435 West Bradley Avenue, Suite C El Cajon, CA 92020 SUBJECT PRE 9541 APN: 209681 -20 Preliminary review of your project was conducted on November 9, 1995. Listed below are the issues raised by staff. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. The prelimlnarv review does not represent an in-depth analvsis of vour proiect. Additional issues of concern mav be raised after vour afmlication is submitted and processed for a more specific and detailed review. Plannina: 1. 2. 3. 4. 5. Withstanding comments listed below, the proposed development complies with the City's General Plan, Zoning Ordinance, and the Carlsbad Airport Business Center Specific Plan. All setbacks, building height, parking, lot coverage, architectural and driveway standards are in compliance, and the proposed use is appropriate for this property. The proposed development is in the PM (Planned Industrial) Zone. Development in the PM Zone requires a Planned Industrial Permit subject to the Planning Director's discretion. Application materials can be obtained at the Planning Department front counter. Staff could not determine with accuracy if the amount of outdoor employee eating area provided satisfies the minimum requirements. A minimum of 2,978 square feet of outdoor eating area is required per the PM Zone. We estimate the proposed employee eating area at 1,700 square feet. The refuse/recycling bin enclosure is not designed per City standards. City standards require pedestrian access through the rear of the enclosure. Add dense foliage where ever possible to screen and/or soften the loading bay fronting Loker Avenue. Do not, however, add plants in locations which will impede safe movement of vehicles and pedestrians (i.e. interfering with safe site distance). 2075 Las Palmas Drive - Carlsbad, California 92009-1 576 - (61 9) 438-1 161 @ Enalneerlng: 1. The location of driveways opposite the site are not shown and this makes support of the proposed locations uncertain for this preliminary review. a. The southerly driveway location is potentially acceptable since there would be no left turn conflicts into the opposite driveway across the street. b. The northerly driveway will need to be located a minimum of 150 feet from the driveway on the opposite side of Loker Avenue in order to avoid left turn conflicts. The distance is measured along the centerline of the street and ends at the midpoint of each driveway. 2. The site plan does not show proposed topography or surface elevations. Therefore, only general comments can be made concerning drainage. a. The project will need to meet the City National Pollution Drainage Elimination System (NPDES) requirements. b. The City Standard minimum grade is one percent. c. Because the building is proposed to be close to the connection to the public storm drain system, a storm drain channel or piping system around the building may be required. Drainage from the parking lot must flow through earth or vegetated swales for NPDES purposes. Please contact David Rick at (619) 438-1 161, extension 4328 if you have any questions. Sincere GARYP/ WAYNE Assistant Planning Director / GEW: DR: kr C: Bobbie Hoder Dee Landers Bob Wojcik Ken Quon File Copy Data Entry