Loading...
HomeMy WebLinkAboutPIP 96-03; Hunsaker Carlsbad I; Planned Industrial Permit (PIP) (5)1 City of Carlsbad September 17, 1996 Brian Hunsaker PO Box 2423 Santa Ana, CA 92707 SUBJECT: HUNSAKER INDUSTRIAL BUILDING - PRE 96-40 APN: 209-082-08 A preliminary review of your project was conducted on September 12, 1996. Listed below are the issues raised by staff. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. The preliminary review does not represent an in-depth analysis of vour proiect. Additional issues of concern may be raised after your application is submitted and processed for a more specific and detailed review. Plannina: 1. The project site is zoned Planned Industrial (P-M) and designated Planned Industrial (PI) in the City’s General Plan. The proposed manufacturing and distribution use is allowed under these designations. The P-M zone requires the processing and approval of a Planned Industrial Permit (PIP) prior to issuance of grading or building permits. A copy of the PIP application materials are enclosed. 2. The project site is located within the Carlsbad Airport Business Center Specific Plan (SP 200) and subject to the provisions contained therein (copy enclosed). Following are a list of aspects of the proposal that do not appear to conform to provisions of SP 200: a. Front and street-side yard setbacks of 35 feet are required. Only walkways, driveways serving the parking areas, architectural walls and monument signs are allowed within the setback areas. No parking can intrude into the setbacks areas. b. Except for the approved driveways and sidewalk locations, the entire area from the curb to a point 29 feet beyond the right-of-way line shall be landscaped. The proposed walkway along Sea Otter Place must be outside of this 25 foot landscaping area. In addition, berming is required between the public streets and the parking area. Since no topographic 2075 Las Palmas Dr. Carlsbad, CA 92009-1576 (619) 438-1161 - FAX (619) 438-0894 @ PRE 96-40 - HUNSAKER uqDUSTRIAL BUILDING SEPTEMBER 17,1996 PAGE 2 information is given, the size of the berm cannot be established. Please refer to page 10 of the enclosed specific plan document for details on berming requirements. c. Outdoor employee eating areas, a minimum of 300 square feet per 5,000 square feet of building area, are required. The eating area shall be landscaped, equipped with outdoor furniture, located such that a sense of privacy is apparent and easily accessible to the employees of the building. Please indicate where this eating area will be located. 3. Parking requirements are based upon the total square footage of each proposed use. Since no breakdown of uses was provided, no specific comments can be made. Office uses require one space per 250 square feet of gross floor area, manufacturing uses require one space per 400 square feet of gross floor area and warehousing uses require one space per 1,000 square feet of gross floor area. A deed restriction limiting the square footages of uses to ensure adequate parking will be a condition of approval for the project. Please also identify the location of all parking for physically challenged individuals. 4. No architectural elevations were submitted therefore no comments on architecture can be made. Maximum building height is 35 feet to the peak of the roof. According to the Specific Plan, plain tilt-up and box-like structural forms shall be avoided. 5. No landscaping plans were submitted therefore no specific comments on landscaping can be made. The City’s Landscape Manual does require a minimum eight (8) foot landscaped perimeter around open parking areas. The submitted plan appears to meet this requirement. One tree is required for every four (4) parking stalls, therefore they will need to be located in the parking islands as well as the landscaped perimeter. Ennineerinn: 1. The proposed driveways need to consider the required minimum spacing (300 feet) and conflicts with adjacent driveways. Attached is a driveway plan that shows the accepted locations of driveways within the Specific Plan for this site. The idea of sharing a driveway on Loker Avenue East may resolve one driveway issue. Additional driveways on lots adjacent to this development should be shown. If the lot is vacant, please assume the location will correspond to the approved Specific Plan driveway plan. 2. The width of the driveways is 30 feet minimum. A width of 36 feet should be used for the proposed use considering the volume and type of traffic anticipated. " PRE 96-40 HUNSAKER AI qDUSTRTAL BUILDING SEPTEMBER 17,1996 PAGE 3 3. The multiple loading bays should be striped and identified. 4. Onsite drainage systems should incorporate NPDES standards. 5. Proposed grading, including cut and fill or export quantities, should be shown. 6. Although the proposed parking dimensions appear to be satisfactory, a standard detail for typical parking dimensions should be shown. 7. The existing sewer and drainage easements should be shown. The access holes or cleanouts should also be shown. Enclosed is a red-lined checkprint. Please return this checkprint with any future resubmittals. Feel free to contact Mike Grim at (619) 438-1 161, extension 4499 if YOU have any questions. GARY E. WAYNE Assistant Planning Director GEW:MG:kr C: Bobbie Hoder Chris DeCerbo Bob Wojcik Clyde Wickham File Copy Data Entry