HomeMy WebLinkAboutPS 00-75; Hoehn Honda; Sign Permits/Programs (PS)ClTY OF CARLSBAD COMlY DE
Crty of Carisbad
2075 &s Palmas Drive
Carisbad, CA Y2009
(760) 43&116I
SIGN PROGRAM FEE RECEIPT NO.
REVIEW FOR SIGN PERMIT
PSanning Department
All plans submitted for sign ptrmits/sign pmgraxns shaH consist of a minimum of a site plan and sign
elevations wntaining the fallowing infurmation:
1. Northamnvandscalc.
2.
3.
4.
5.
Location of existing buildisgs or structures, parking m, and vehicular access points to
Location of all existing and proposed signs for the property.
Distance to the property Wds) for all proposed hestanding sign($).
Provide an eIevation for dl proposed sign(s) which specifics the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Matttiah the sign@) will bc constructed of
C. Proposed sign copy.
the PNPntY.
APPLICANT MUST SUBMJ" THREE (3) SETS OF SIGNlSlTE PLANS, A COMplLETED
APPLICATION FORM, AND THE APPLICATION FZE.
The amlieation mud bt submitted prior to 4:OO b.m, Average processin~) time: 2 wccks
NAME OF PROJECT:
ASSESSOR PARCEL EJUMBER; 2 [ I - 060 - 141 0 a
RELATED PLANNING CASE NUMBER(S):
S1GN TYPE: (*fGammercial (b) Industrial (c) Residential
(g) Community identity (h) Service Sm. Prices (i) Campaign (d) RealEstaze (4 F-Y (0 Mwu-
SIGN PROGRAM AND/OR
SPEClFIC PLAN CRITERIA Yes0 No 0 SpificPhNurnber
SIGN ORDINANCE:
COASTAL ZONE: YCS~ NO ~oasta~pennit Yes NO 0
EXISTTNG SIGNS: Type Number Size (In Square Feci)
(a) Pole
(b) Monument
(c) Wall 5
PERMITS ISSUED FOR EXISTING SIGNS: Yes & No0 Date ;-s-ef bs qyg/
p5 42-N TOTAL BUILDING STREET FRONTAGE 134 fi.
TOTAL SIGNAGE AI.OWANCE 27 3 q. ft.
REMAINING SIGN ALLOWANCE AT PRESENT 172- sq. fi.
PROPOSED SIGNAGE (SQ. Ff.) 117.7 sq. fi.
V6J EXISTMG SIGNAGE (SQ. FT.) */06 - sq. ti. WdwflQ3’
KEMAINMG SIGN ALLOWANCE AFTER PROPOSED SIGN kv.3 4. ft.
ALL THE ABOVE INFORMATION IS TRUE AND LEGALOWNERANDT€iATALLTHEABOvElNFORMA- CORRECT’KTHEBJ3TOFMYKNOWLEDG€ TlON IS TRUE AND CORRECT TO TI4E BES’I’ OF MY R
PLANME R CHECK LIST:
M Field check by planner.
YZ. Within maximum lengih, area
v3.
W Location: + In right-of-way
Style consistent with Sign Program ador Specific Plan criteria, if applicable.
In visibility triangle at corner -3
0 on roof
&+&b. 6.
Pole and monument signs to be checked by Bob Johnson, Traffic Engineer, for visibility issues.
When approved routc cypy to Data Entry
APPROVED Planner: _. L&c/ I Date: 6-23 ....* t~*..**t.*~o...?tttt*t*.**t*t**t~*
Form 10 09/97 Pagc2of2
City of Carlsbad
1635 Faraday Avenue Carlsbad CA 92008
Applicant: PLASTI-LINE WEST
Description
PSO 0 0 07 5 30.00
Receipt Number: ROO13215
Transaction Date: 06/23/2000
Transaction Amount: 30.00
14-9 1/L’ I .“oehn L
Honda
before after
I I Fllswms: HO Hoehn Elevations
WIasti-Lin e, In cm Oate
Photo Card Post Office Box 59043 Knoxville, Tennessee 37950-9043
(423) 938- 1 5 1 1
Customer
Street Address
City / State
Hond
I
- ------ - ---
2-5-99 I AG I RTP LUIIL n ~larcmc - DATE INI IT^ ECN DESCRIPTION OF CHANCE cu-
F DU =.015 R SU.03 JxI401s mar PI ICATFD. UWPECIfIED RAD11 ~0~~s: a - - - - - lOPERTY OF PIASTI-LINE. INC mTT
3 f
SCALE: --- I DATE: 2-3-99 IDATE: --- - HONDA
5x5 SW FLUSH MT INSTALL DpomDb
SHT 1 OF21mm"yLs B20685
71 65
r3
65
SI
7 7' I
3/6 BOLE MRU WALL x X
3/8 LAC BOLTS w/wau, x ----- I-----
J/C UG BOLTS ----- )( I----- . 3/tT TOCCLE BOLTS --- -----I X
INSTALI ATION INSTRUCTION$
(SEE "INSTALLATION FIELD MANUAL' DWC# A15552 FOR FOUNOATION AN0 INSTALLATION STANDAROS)
1. TEST LIGHT SIGN UPON DELIVERY & NOTIFY PIASTI-LINE OF ANY PROBLEMS. 2. UNCWTE SIGN AND REMOVE TOP AND BOTTOM CAP. 3. LIFT SIGN AND POSITION ON WALL. MARK POSITIONS OF MOUNTING AND ELECTRICAL HOLES THROUGH BACK PER DIMENSIONS GIVEN ON INSTALL DRAWING. 4. DRILL MOUNTING AND ELECTRICAL HOLES 1N WALL. 5. MOUNT SIGN ON WALL. (SEE HARDWARE TABLE) 6. RUN ELECTRICAL TO SIGN AND TEST LIGHT. 7. REMOVE EYEBOLTS AND REPLACE WITH BOLTS. 8. CLEAN FACE AND CABINET. 9. CLEAN JOBSITE OF ANY INSTALLATION DEBRIS. 10. INSTALLATION SHALL CONFORM TO THE NATIONAL ELECTRIC CODE AND ANY OTHER APPLICABLE LOCAL CODES. THE SIGN SHALL BE GROUNDED IN A MANNER SPECIFIED BY THE N.E.C.
SPFCIFICATIONS:
LAMPS: (5 -F64T12/CW/HO BALLAST: )I )-JEFF. 256-672
VOLTAGE: 120 VAC 60 HZ
LOAD: 4.0 AMP CIRCUITS: (1)-20 AMP SERVICE: REMOVABLE TOP/BOTTOM CAPS CRATED WT: 210 LBS UNCRATED W: 172 LBS WINDLOAD: 30 PSF.
P/N: 00-00-005-8189 I PLASTI-LINE, INC.
P.O. Box 59043- KNOXVILLE. TN 37950-9043
DSGNR: KES IDWG.BY: KES )CH#K BY: ---
0 0 a N
UJ
I
3
REMOVE LIFTING ANGLES 35 1/16 J
h REPLACE HARDWARE (SEAL TO PRNENT WATER LEAKS) 8
I1
68 29/32
..
t
ELECT. ENTRANCE f
BLOCKING AS REQUIRED TYP. f
b
HARDWARE
SEF CHART
ELECT. SERVICE r BY INSTALLER
. /
MOUNTING HOLE
LOCATIONS MP. I P.O. BOX 5904.3- I PLASTI-LINE, INC. I
KNOXVILLE, TN 37950-9043
DSGNR: KES IDWG.BY: KES ICH'K BY: ---
SCALE: --- I DATE: 2-3-99 I DATE: ---
5x5 SW FLUSH MT INSTALL DcsQmw
15MM 6500- WHITE NEON
BY VOLTARC
WALL SECTIOI.1 m.
LETTERS SHIPPED WITH 1/2- STR. EMT CONNECTOR WD 36' LEADS IN PLACE.
- LETTERS RIVNUTS SHIPPED WITH 3/8 IN PLACE. +
MOUNTING DETAIL
1.
2.
3.
4.
5.
6.
7.
-15- EMT AND ALL FLEX COFlOUlT AND CONNECTORS SUPPLIED IN FIELD KIT
1 N STALLATIO N IN ST R UCTlO N S
UNCRATE SIGN COMPONENTS AND INSPECT FOR DAMAGE. NOTbY
~LASTI-L!NE. Of ANY PROBLEMS.
pO'jlTlON FUCL SIZE TEMPLATE ON WALL PER ELEVATIONS. USING THE FULL SIZE TEMPLATE LOCATE POSITION Of MOUNTING
HOLES AND ELECTRICAL HOLES. DRILL 1-0 HOLES fOR THE
CONDUIT AND BACKBORE I - 1/2"0 FOR THE FITTINGS, ON THE BACK OF THE LETTERS. DRILL HOLES FOR THE MOUNTING sTUoS(SEE MOUNTING DETAIL).
INSTALL LETTERS ON '1HE WALL WITH THE CONDUIT AND THE
STUDS' PENETRATING THE WALL COMPLETELY. SILICONE ALL PENETRATIONS.
BLOCKING ONLY IF REOUIRED.
SECURE LETTERS ON THE BACKSIDE OF THE WALL USING
MAKE UP THE PRIMARY CIRCUIT AND THE FINAL CONNECTION
TEST LIGHT THE SIGN AND CLEAN SITE OF ALL INSTALIATION
TO POWER BY 1HE WIRING DIAGRAM SHOWN ABOVE.
DEBRIS. TAKE PHOTOGRAPIiS 0f"ltlE FRONT AND BACKSlOE OF TtlE WALL PER THE FIELD SERVICE MANAGERS INSTRUCTIONS.. '
e- -
0- =s
CUSTOM BLUE ACRYSTEELJ FACES WITH JEWELITE
CD
.
5: -=c W cu
0 0
0 cu
n -, .
NQTES:
VOLTAGE: 120 V, 60 HZ . TOTAL CONN LOAD: 2.1 AMPS PER LTR CIRCUJTS: AS REOUIRED MAX DESIGN WIND LOAD: 30 PSF
I PLASTI -LINE, INC.