Loading...
HomeMy WebLinkAboutPS 04-76; Threads Cleaners; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4600 SIGN PROGRAM FEE RECEIPT NO. - REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. 3. 4. 5. Location of existing buildings or structures, parking areas, and vehicular access points to the property. Location of all existing and proposed signs for the property. Distance to the property line(s) for all proposed freestanding sign(s). Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. C. Source of Illumination. D. Proposed sign copy. Materials the sign(s) will be constructed of. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGNBITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:OO P.m. Average processing time: 2 weeks NAMEOFPROJECT: -3% -\ ADDRESS OF PROJECT: ss\.c \6hf ASSESSOR PARCEL NUMBER: 2-/a -/ab- oy RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential (e) Service Station (i) Public Park jj+Commercial (0 Prof. Care 0) Produce Stand (c) Officehdustrial (g) Theater (k) Nursery (d) HoteVMotel (h) Govt/Church (1) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes* No 0 Specific Plan Number VILLAGE REDEVELOPMENT AREA Yeso No 0 Requires VR Approval SIGN ORDINANCE: Yeso No 0 COASTAL ZONE: Yeso No Form 10 Revised 01/04 Page 1 of3 ....................................... EXISTING SIGNS: TYPE Construction For Sale Banner I TYPE MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM NUMBER PROPOSED SIGN SIGN SIGN ALLOWED AREA AREA HEIGHT I NUMBER SIGN AREA I SIGNHEIGHT I Pole Monument Wall Suspended I I Directional I Canopy I I' Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: PROPOSED PERMANENT SIGNS: ALLOWED I Monument 1 yc Wall. I I , I I Suspended I I I Directional I Freestanding (Project Identity) PROPOSED TEMPORARY SIGNS: Yes 0 No 0 Date MAXIMUM SIGN AREA PROPOSED MAXIMUM PROPOSED HEIGHT HEIGHT PROPOSED SIGN HEIGHT **************************t***~******** Form 10 Revised 01/04 Page 2 of3 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) / sq. ft. sq. A. / REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) /7\u_ sq. ft. REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN # sq. ft. ! Y I APPLICANT OWNER ' NAME(PRINT0RTYPE) I NAME (PRINT OR TYPE) H MAILING ADDRESS CITYANDSTATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE MFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE SIGNA- DATE MAILING ADDRESS u CITY AND STATE ZIP TELEPHONE 1 I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE MFORMA- TION IS TRUE AN-T TO THE BEST OF MY KNOWLEDGE& \ II PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program andor Specific Plan criteria, if applicable. 4. Location: *:* In right-of-way 5. 0 In visibility triangle at comer Pole and monument signs to be checked by Traffic Engineering, for visibility issues. 6. When approved ro APPROVED: Planner: Date: s- zs-oy Y ....................................... Form 10 Revised 01/04 Page 3 of 3 05128/2%04 13: 56 6192318389 . PAGE 01/02 1660 Union Street 4m Flm slanDisg0,cA 92101 Tei: 61923 1.9606 Fax: 619.231.8389 Facsimile Transmittal Sheet To: Phone: Paw: 2 (includiq this cover sheet) Fu: 858-549- 1654 Date: May20,2004 Re: Island@c&bed - Submarina cc: EncIoscd is the sign apvd for T)rreads, If you have any comments or questions, pk- do not hesitate to dl myofXi~ at 61 9-243-51 17. 05/20/2004 13: 56 6192318389 PAGE 02/02 EMORANDUM Date: Uay20,2004 To: AI - Alcw Signs From: JohnHurtz Re: THREADS - SIGN APPROVAL This rnmorandum hereby servcs as landlord approval of the sign drawings mtntly submitted fm tbe abow-mentioned tenant at the Island@carlsbad. If you have any comments or questions. pk do not hesitate to contact my office at 61 9-2434 1 17. Thank you. 1 f ~ voltage 1001to5000 !, ~~ A B C D 1Rinch 1Rinch none 3411-1 Listed sign sedion (consisis of insulating boots, insulating sleeves, mounting plates and reverse channel tube supports) indoor only. Sheet metal mew Reverse channel (any materii 5001 to 1 oo00 1oOnto15ooo isling marks: LISTED 314 inch 3/4 inch 1 /4 inch if linch linch 7WWt Li& mark sign section label shall be on each letter and transfnrrner enclosure. fhe M blank space identifies the number of each sign section. The socond bhnk space indicates ihs total number of sign sections. All ryhk reserved. Wo pari of ths work mered by Le wpyn(lM hereon may ba reprodud or usad m any form 01 by any means anphR, sbdmnle. or msekamwl, lndudiw ph-, mdlng, taptng, 01 nfomrhon storao6 and rctnsvai systems - mthout wnttsn psnntEslon of "J publisher, cxcspt bat copies of mdndnrdual pagas may be made by a bWfi abetncal ygn mbllabon hrm for the soh pupm of provdng pw OR ths nshUahon of electmall slgm or outW Ilghtmg, hout the petmn of the publuha Fasteoers as required by the bar jurisdiction. Primary electrical source (112 in. minimum conduit, metal shown). NEC600-6Q600-21. Listed disconnect switch in primary to be (Many interpret transformer enclosure to 38 in. minimum lied Rex (metal shown) and lied GTO cable (secondary side only and to the next sedion letter). NEC 110-3@) & NEC 600-31. sight (meximum 50 ft.1 of sign. be ptt Of sip.) NEC 110-3(b), 600-2,6004. HALO-ILLUMINATED (REVERSE CHANNEL) LETTER, INSULATED BOOT AND SLEEWNG - Date: October 1994 - Scale IAEl None Dwg. Na ULm-MB SPACING TABLE A Between primarywiring and insulated high vobv3 Wiring. B. Between insulated high voltage wiring and dead metal where mnng parallels dead metal for more than l'within sign sections. C. Between neon tube (if over 7500volt circuit) and nearest surface. D. Between uninsukaed high vdtage conductors or components. (Mid- point-grounded transformer)and dead metal (ground), low voltage circuit conductors and high vdtage conductors of opposite polarity. spacings maintained per spacing table. Listed sign section (consists of transformer urdess marked for indoor only. Accessible. NEC 600-32(e). Grounded endowre. - and endosure) suitable for outdoor kcations Fasteners as required by focal jurisdicbon. / eOnding jumpers (minimum No. 14 copper) required (1) flexible metal conduit in gmund return path exceeds 6 ft. (NW: 350-5 Exc. No. 2), (2) conduit is nonmetallic, andlor (3) receptac(e uses gaskets that will impair grwnd return path or dired metal-to-metal contact NEC HO-l4(a), 250-43@), 25@79(f), WE97,25&113 & W5. Installation of signs listed per UL48 Note: Installation requirements only. Manufacturing requirements contained in UL48. r ~~ ~ by qualified electrical testing laboratory ELECTRIC SIGN SECTION NO. XX-123456 L_I of m 3 I% I z d z P 4 s-toref-ron-t; 1ent;gh 29 9ee.t; 4 inches 113,in 22c f Client threads cleaners LICEN4E NO. 726492 Location 8535 ARJONS DRIVE $AN DlEGO CALIFORNIA 921 26