Loading...
HomeMy WebLinkAboutPS 05-145; Den The; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760)602-4610 PLANNING APPLI REC'D BY _ DATE SIGN FEE _J SIGN PROGRAM FEE. RECEIPT NO. /(L REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: ~ ADDRESS OF PROJECT: ASSESSOR PARCEL NUMBER: RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential (c) Office/Industrial (d) Hotel/Motel (e) (0 (g) (h) Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes VILLAGE REDEVELOPMENT AREA YesdJ SIGN ORDINANCE: YesQ COASTAL ZONE: Form 10 Revised 12/04 YesD No No No No Specific Plan Number Requires VR Approval Page 1 of4 EXISTING SIGNS: TYPE Pole Monument Wall li Suspended fr1 Directional Canopy Freestanding (Project Identity) NUMBER • SIGN AREA SIGN HEIGHT PERMITS ISSUED FOR EXISTING SIGNS: Yes PROPOSED PERMANENT SIGNS: NO n Date TYPE Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) MAXIMUM NUMBER ALLOWED £Lv\J2_ NUMBER PROPOSED (SU\S— MAXIMUM SIGN AREA 7^* PROPOSED SIGN AREA lUfe* MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Ib" PROPOSED TEMPORARY SIGNS: TYPE Construction** For Sale** Banner MAXIMUM NUMBER ALLOWED v\\fc\ \\ NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing bow the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Form 10 Revised 12/04 Page 2 of4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building /s P/L v../ Show all property lines ] /P/L . • i £ / S curb line •* / Sight Visibility 1 1 Sight Distance Requirem 1 1 1 1 how setbacks from all cu I 1 1 Street Name(s) 1 i ent irbs North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. » » » » « Form 10 Revised 12/04 Page 3 of4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. 11 . sq. ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. OWNER APPLICANT NAME (PRINT OR TYPE)NAME (PRINT OR TYPE) MAILING ADDRESS MAILING ADDRESS CITY AND STATE ZIP QOEJQctJd, TELEPHONE CITY AND STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: »J* In right-of-way <• In visibility triangle at corner 5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues 6. When approved route copy to Data Entry (AelchAPPROVED: Planner:Date:// Form 10 Revised 12/04 Page 4 of4 City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 Applicant: FORD SIGNS Description PS050145 Amount 45.00 Receipt Number: R0053991 Transaction Date: 11/21/2005 Transaction ID: R0053991 Pay Type Method Description Amount Payment Check 13142 45.00 Transaction Amount: 45.00 DEhe den 8'-9" 1166 sq. Ft. INTERNALLY ILLUMINATED REVERSE CHANNEL LETTERS LETTERS: INTERNALLY ILLUMINATED VW ALUMINUM FACES PAINTED DURANODIC BRONZE. HALOILLUMINATEDW/WHITENEON/30MATRANSFORMERS Reverse Channel Letter Schematic 16" tall Internally illuminated aluminum channel letters with halo light. Aluminum faces painted duranodlc bronze and white halo illumination to read "the den". Signs will be powered by (2) 12.000/ 30 ma (UL 2161) electrical transformers with 6500 white neon, GTO wiring. A disconnect switch Is mounted to side of self contained transformers. Primary's are existing from building, Letter fronts will be .063 aluminum, letter returns will be 3" x .063 aluminum. Attachment 1/4" x 2" pan head screws with plastic anchors (4 per letter) min. All signs are UL approved. 27'storefront ? LANN1N 3UILBJNG amM.r9rAOfftu.eoat 1310-A North Meboie Dr. Vlsl»,CaHfomU 92083 760-631-1936 Fix 760-631-4987 .' Bill Gray ftatawnKB! Stacy F. Bf, StacvF. the den 2744 Carlsbad Blvd. #114 Carlsbad, CA planned project and & nor fo be etfifcfled,aopftd or reproduce wffliotrt fne Mfffenptrmteton ofFonJ j/gni (ncocfft oufflorttedogenf. O IVumlxr 7591 Dau:: 11-04-08 Sheet Number: 1 of 1 Exhibit A (Site Plan) Proposed Community Identification Sign Proposed— Community Identification Sign Washington Slreel " o Store front signs along Carlsbad Blvd. SIGN PLAN THE BY THE SEA PLANNING I^^I^Sl uSJi^i'V/sl'iiPFc- _£^™^£_JLJL^HI ''S'S;MM-'1;':L.'r;