HomeMy WebLinkAboutPS 05-148; Flowers Forever; Sign Permits/Programs (PS)City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-4610
PLANNING APPLICATION # PS
REC'D
SIGN FEE
SIGN PROGRAM FEE
RECEIPT NO.
REVIEW FOR SIGN PERMIT
Planning Department
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
NAME OF PROJECT:
ADDRESS OF PROJECT:
ASSESSOR PARCEL NUMBER:
RELATED PLANNING CASE NUMBER(S):
TYPE OF DEVELOPMENT:
(a) Residential
(b) Commercial
(c) Office/Industrial
(d) Hotel/Motel
(e)
(f)
(g)
(h)
Service Station
Prof. Care
Theater
Govt/Church
(i) Public Park
(j) Produce Stand
(k) Nursery
(1) P-U/OSZone
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA Yes D No Specific Plan Number
VILLAGE REDEVELOPMENT AREA YesQ No D Requires VR Approval
SIGN ORDINANCE: YesQ No Q
COASTAL ZONE: YesQ No D
Form 10 Revised 12/04 Page 1 of 4
EXISTING SIGNS:
TYPE
Pole
Monument
Wall
Suspended
Directional
Canopy
Freestanding (Project Identity)
NUMBER SIGN AREA SIGN HEIGHT
PERMITS ISSUED FOR EXISTING SIGNS: Yes
PROPOSED PERMANENT SIGNS:
No Date
TYPE
Pole**
Monument**
Wall
Suspended
Directional
Canopy
Freestanding**
(Project
Identity)
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
/
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
/?,*>$
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
PROPOSED TEMPORARY SIGNS:
TYPE
Construction**
For Sale**
Banner
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for
potential sight distance and visibility issues. Additional information must supplement this application
showing how the proposed signage will not encroach into the public right-of-way or present a traffic
hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs.
Form 10 Revised 12/04 Page 2 of 4
SITE PLAN REQUIREMENT FOR POLE. MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Traffic Engineering Department, which will not allow signs to be
approved over the counter. Additional time will be required for on-site inspection.
Showbuilding/s
P/l
\.J.i ^i •
Show all prop erty lines j /
i •
| »
•
••
S
curb line •*•
Sight Visibility
1
i
Sight Distance Requirem
1
1
1
how setbacks from all en
l
1
1
Street Name(s)
1
i
ent
irbs
North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
Form 10 Revised 12/04 Page 3 of 4
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
TOTAL BUILDING STREET FRONTAGE
TOTAL SIGNAGE ALLOWANCE
EXISTING SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AT PRESENT
PROPOSED SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN
ft.
tf f/}
, 3
. sq. ft.
. sq. ft.
sq. ft.
sq. ft.
. sq. ft.
OWNER APPLICANT
NAME (PRINT OR TYPE)NAME (PRINT OR TYPE)
—P*
MAILING ADDRESS MAILING ADDRESS
CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHONE
I CERTIFY THAT I AM THE LEGAL OWNER AND THAT
ALL THE ABOVE INFORMATION IS TRUE AND
CORRECT TO THE BEST OF MY KNOWLEDGE.
I CERTIFY THAT I AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE INFORMA-
TION IS TRUE AND CORRECT TO THE BEST OF MY
KNOWLEDGE.
SIGNATURE DATE SIGNATURE/DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: »J* In right-of-way
•J* In visibility triangle at corner
5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner Date:
Form 10 Revised 12/04 Page 4 of 4
City of Carlsbad
1635 Faraday Avenue Carlsbad CA 92008
Applicant: FORD SIGNS
Description Amount
PS050148 .00
Not valid unless validated by Cash Register
PLEASE RETAIN RECEIPT FOR REFUNDS OR ADJUSTMENTS
Receipt Number: R0054250 Transaction ID: R0054250
Transaction Date: 12/02/2005
Pay Type Method Description Amount
Payment Check 7542 45.00
Transaction Amount: .00
P R O P O / -F L O UJ -E R S O R -E V -E R I I - ID 5 I G N PI
1310 North Melrose Suite A
Vista California 92083
Phone (760) 631-193$ Fox (760) 631-4987
FLOWERS FOREVER
Account Rep: _ A. GELBMAN
619-300-3422
Project Manager^ ___
Drawn By: A. GELBMAN
Project / Location:
POINSETTIA VILLAGE,
CARLSBAD, CA.
Thfc original drawing Is prov/aeo as part of a
,planned.pfoieciand Is not lobe exhibited,
or reproduced without the written
of ford Signs he or Its authorizedSIGN FSSMUT NO. PS
i-LANNJNG
BUILDING
D-ETRILS
11'-5"
10
SQ. FOOTAGE
5.8
FLOWERS FOREVER B 10. SQ'
TttScSQ. FT
A- ALUMINUM CABINET, W/ ,090 FACE, PAINTED MATTE BLACK, W/ y2" PUSH-THRU ACRYLIC FACES (TRANSLUCENT WHITE
B- 3" DEEP REVERSE CHANNEL LETTERS, ALUMINUM, PAINTED MATTE BLACK, W/ WHITE NEON TO VHALO' AT NIGHT.
LTR. -3".1.5" SPACE
(6) EA.- 3" SCREWS
THRU SPACERS
TO WALL ANCHORS
3/16" CLR. LEXAN BACKS
24g SHT. METAL LTR.
ATTACHED TO LEXAN
GLASS TUBE SUPPORT
NEON
UL APPROVED INSULATING
GTO WIRE TO ELECTRODE
1/4" DRAINAGE HOLE
SHT. METAL ENCLOSURE
SCREWED TO WALL
EMERG. DISC. SWITCH
GTO CABLE TO TRANSF.
110 POWER.
TO TRANSF.
TRANSFORMER BOLTED TO
ENCLOSURE
METALLIC SLEEVINGTHRU WALL
(jYP.REVERSE CHANNEL LETTER)
ALL COMPONENTS UL APPROVED
110 PWR SUPPLY
ALUM. CABINET W/
LIGHTING WITHIN
y SCREWS INTO
WALL ANCHORS
0 11 -3/4" ACRYLIC LTRS
PUSHED THRU FACE, GLUED
W/ TRANSL. FACE
\090ALUM. FACE W/
LETTER OPENINGS
ROUTED OUT
(jTYP.CABINET W/ PUSH-THRU'S^)
ALL COMPONENTS UL APPROVED
INCORPORATED
1310 NctthMetrose Suite A
vwaccdfomta 92083
Phone (760) 631-1936 Fax (760) 631 -4987
C-48Uc.*7171S7
Account Bep: A, GELBMAN
Project Manager:
Drawn By; A. GELBMAN
Project / Location:
POINSETTIA VILLAGE,
CARLSBAD, CA.
This original drawing Is provided as part of aplanned protect and is not to be exhibited,
copied or reproduced without the written
permission of Ford Signs Incortts authorized
agent.
Job Number:
File Name: FLOWERS FOREVER
Date:
Sheet Number:Of
X
";^,.-^'S^^'.^^^'3??i^F'} /C^x
,j ^x^^t^^QlllW'f^-Q, •-•</ s.£-.*!&^ ^ScMiiSaMiiiMiu-^ ^ .-^ ^ .-? # .w y/ifc/iV^-^ ^^ .-^^ *& -^. ^V*>«%A *-'*
»~, •* f ic- ;5P^" '? £T v/ •^ • -%.^' f / $ I
fa^m^r^w^v^^:.-m::^ //i M^^S^^^^to^A'i^y//,-'J // &£• M .e^P.^^& -=P.^'S=: %> "-• ("^<A\\ \V_-^ ./^ / /.
VI
nz
I
•8
SIQN LOCATION MAP - POINSETTIA VILLAGE