HomeMy WebLinkAboutPS 05-153; Hampton Inn; Sign Permits/Programs (PS)City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-4610
PLANNING
REC'D BY
DATE
SIGN FEE
SIGN PROGRAM FEE.
RECEIPT NO.
REVIEW FOR SIGN PERMIT
Planning Department
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy. "*""'
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4;00 p.m. Average processing time: 2 weeks
NAME OF PROJECT: /-/*i*yr/i>4
ADDRESS OF PROJECT: ^
ASSESSOR PARCEL NUMBER:
RELATED PLANNING CASE NUMBER(S):
TYPE OF DEVELOPMENT:
(a) Residential
(b) Commercial
(c) Office/Industrial
Ca^Hotel/Motel
(e)
(f)
(g)
(h)
Service Station
Prof. Care
Theater
Govt/Church
(i) Public Park
(j) Produce Stand
(k) Nursery
(1) P-U/OSZone
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA Yes
VILLAGE REDEVELOPMENT AREA YesQ
SIGN ORDINANCE: YesQ
COASTAL ZONE: YesQ
Form 10 Revised 12/04
No
No
No
No
Specific Plan Number
Requires VR Approval
Page 1 of 4
EXISTING SIGNS:
TYPE
Pole
Monument
Wall
Suspended
Directional
Canopy
Freestanding (Project Identity)
NUMBER SIGN AREA SIGN HEIGHT
PERMITS ISSUED FOR EXISTING SIGNS: Yes
PROPOSED PERMANENT SIGNS:
No Date
TYPE
Pole**
Monument**
Wall
Suspended
Directional
Canopy
Freestanding**
(Project
Identity)
MAXIMUM
NUMBER
ALLOWED
/
2
NUMBER
PROPOSED
/
^
MAXIMUM
SIGN
AREA
-30 4=>
^1.54.-i
PROPOSED
SIGN
AREA
t1&
• --££>'*
MAXIMUM
SIGN
HEIGHT
<$'
•zy"
PROPOSED
SIGN
HEIGHT
f
W"
PROPOSED TEMPORARY SIGNS:
TYPE
Construction**
For Sale**
Banner
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for
potential sight distance and visibility issues. Additional information must supplement this application
showing how the proposed signage will not encroach into the public right-of-way or present a traffic
hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs.
Form 10 Revised 12/04 Page 2 of 4
SITE PLAN REQUIREMENT FOR POLE. MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Traffic Engineering Department, which will not allow signs to be
approved over the counter. Additional time will be required for on-site inspection.
Show building /s
P/L
\~J.•
! /i •
Show all prop erty lines ] •P/L : S.
i •
1 /
/
*••
S
curb line •"
•
Sight Visibility
1
i
Sight Distance Requirem
1
1
1
how setbacks from all cu
l
1
-J
Street Name(s)
1
i
ent
crbs
North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
Form 10 Revised 12/04 Page 3 of 4
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
TOTAL BUILDING STREET FRONTAGE
TOTAL SIGNAGE ALLOWANCE
EXISTING SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AT PRESENT
PROPOSED SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN
ft.
ttt.
. sq. ft.
. sq. ft.
. sq. ft.
sq. ft.
. sq. ft.
OWNER
NAME (PRINT OR TYPE)
MAILING ADDRESS
CITY AND STATE ZIP TELEPHONE
/^i^fr/y-/^*^, <Z/\ I2&6o fYf-ff/Q-V"*
\ CERTIFY THAT /AM THE LEGAL OWNER AND THAT
ALL THE ABOVE INFORMATION IS TRUE AND
CORRECT TO THE BEST OF MY KNOWLEDGE.
SIGNATURE DATE
APPLICANT
NAME (PRINT OR TYPE)
MAILING ADDRESS
CITY AND STATE ZIP TELEPHONE
I CERTIFY THAT7! AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE INFORMA-
TION IS TRUE AND CORRECT TO THE BEST OF MY
KNOWLEDGE.
SIGNATURE DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: •> In right-of-way
*S« In visibility triangle at corner
5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner:Date:
Form 10 Revised 12/04 Page 4 of 4
SIGN SPECIFICATIONS:
LIGHT-COLORED BUILDING:
• .040" THK. ALUMINUM RETURNS PAINTED
TO MATCH #313 DARK BRONZE.
• .050" THK. ALUMINUM CAD CUT LETTER
BACKS.
• LETTER INTERIORS PAINTED STARBRIGHT
LIGHT ENHANCING PAINT.
• .187" #2283 RED LEXAN FACES.
• 1" THK. DARK BRONZE JEWELITE.
• RED GELCORE TETRA L.E.D. ILLUMINATION.
• REMOTE POWER SUPPLIES.
• LETTERS TO BE MOUNTED FLUSH TO
BUILDING WALL.
NOTE:
SPACING BETWEEN LETTER SETS HAS BEEN
INCREASED.
END VIEW
CHANNEL LETTER LAYOUT (REMOTE)
SCALE: 1/2" = 1'-0"
;fiyjK£^7.-^ait06^&»5Mf!Hfl¥ftB5!>i»K»fe '&ti^mr£n'A*Mx&w3c& ti>?m&ti3£S!*> Hrltfe.jgdiS
WEST ELEVATION
SCALE: 3/32" = 1'-0"
Chandler
Signs
3201 Manor Way
Dallas.TX 75235
12106 Valliant Drive
San Antonio, TX 78216
. . P.O. Box 43123www.chandlersigns.com uuisviiie, nr 40251
REVISION / DATE
214-902-2000 750 E. Hwy. 24 - Bldg. 2, Ste. 200 719-487-1507
Fax 214-902-2044 Woodland Park. CO 80863 Fax 719-687-2506
210-349-3804 1335 Park Center Drive - Ste. 200 760-967-7003
Fan 210-349-8724 Vista, CA 92081 Fax 760-967-7033
502-489-3660 Ttib drawing b the property of Chjndter Signs, UR and alrighti
Fax 502-254-3843 to to use for reproduction »™ re«r™) by Chandler Signs. LR
R1:10/26/05:JC: REVISED LAYOUT
R2:10/28/05:JC: REVISED LAYOUT
R3:11/04/05:JC: REVISED LAYOUT
R4:11/18/05:JC: REVISED SIGN4
APPROVAL / DATE
Sales
Estimating
Art
Engineering
landlord
Design* C55874R4 Sheet 1 of 4
Sales/Coordinator R. HANSON / R. KIRSCH
Designer J. CASTILLO Date 10/07/05
(Jfamptotu Client HAMPTON INN
Street YARROW DRIVE &
PALOMAR AIRPORT ROAD
FINAL ELECTRICAL
CONNECTION
BY CUSTOMER
City/State CARLSBAD, CA
END VIEW
CHANNEL LETTER LAYOUT (REMOTE)
SCALE: 1/2" = 1'-0"
SIGN SPECIFICATIONS:
LIGHT-COLORED BUILDING:
• 040" THK ALUMINUM RETURNS PAINTED
TO MATCH #313 DARK BRONZE.
• .050" THK. ALUMINUM CAD CUT LETTER
RACKS• LETTER INTERIORS PAINTED STARBRIGHT
LIGHT ENHANCING PAINT.
• 187" #2283 RED LEXAN FACES..'TTHK DARK BRONZE JEWELITE.• RED GELCORE TETRAL.E.D. ILLUMINATION.
• REMOTE POWER SUPPLIES.
• LETTERS TO BE MOUNTED FLUSH TO
BUILDING WALL.
SPACING BETWEEN LETTER SETS HAS BEEN
INCREASED.
NORTH ELEVATION
SCALE: 3/32" = 1-0"
••••^^
••
r>
WWW.
••••MChandler
Signs
chandlersigns.com
i^^am
3201 Manor Way
Dallas.lX 75235
12106 Valliant Drive
San Antonio. TX78II6
RO. Box 43123
Louisville, Kf 40253
••••1214-902-2000
Fax 214-902-2044
210-349-3804
Fax 210-349-8724
502-489-3660
Fax 502-254-3843
-^^— •"
•••^-••i^fc^^^™
750 E. Hwy. 24 - Bldg. I, Stt. 200 ™-**™S°7Woodland Park. CO 808*3 Fax 719-687-2506
1335 Park Center Drive -St.. 200 ™°-»*"°,03
Virta.CA 92081 Fax 760-967-7033
^te^to^Uictloo « «er«l by Chimjer Slgm. LR
^
R1"IO/26/05:JC: REVISED LAYOUT
R2'10/28/05:JC: REVISED LAYOUT
R3"I1/04/05:JC: REVISED LAYOUT
R4-11/18/05:JC: REVISED SIGN0
Client
<ile>
fsOnaOne
•rt
Engineerinf;
1 anfllonl
Design #
u^^^^fm
C55874R4
m^^^—^^^
Sheet 2 of 4
Sales/Coordinator R. HANSON / K. IMKSUM
Desiener J. CASTILLO Date 10/07/05
Client
YARROW DRIVE &
Street PALOMAR AIRPORT ROAD
FINAL ELECTRICAL |
HAMPTON INN «SSSS
City/State CARLSBAD, CA
040" THK ALUM PETUPN
1" JEWELITE RETAINER \
V
.1ST THK. LEXAN, VIVAK HT,
OR SOLAREX K FACES.
SEE PREVIOUS SHEET FOR
COLOR TREATMENT.
CUT BACKS
GELCORE TETRA RED
L.E.D. (5 PER FOOT)
PAINT LETTER INTERIOR
wift STARBRITE L.E.R
1
t
!
, J\
jj
p
Mkn
WEEP HOLES IN LOW POINTS
OF LETTERS. (2) MIN. LISHT
SHIELD REQUIRED AT EA. HOLE.
.375' C
] — AS RE
CONS!
mnpanig)
2"x2"
LETTE!
^i
IA HARDWARE
aUIRED PER WALL
"RUCTION.
SALV.
N BACK OF
?.
ALL-THREAD CONDUIT
PASS-THRU WALL.
j*-— SPLICE CONNECTOR
GECLPS-3 POWER
SUPPLY BEHIND WALL.
(MUST BE SHIELDED FROM
1 THE ELEMENTS.)
0
Q - — J-BOX with PRIMARY
O ELECTRICAL (BY OTHERS)
040" THK ALUM RETURN
\
OR SOLAREX K FACES.
SEE PREVIOUS SHEET FOR
COLOR TREATMENT.
CUTBACKS
OELCORE TETRA RED
LE.D. (5 PER FOOT)
PAINT LETTER INTERIOR
with STARBRITE LE.P.
i
T
, A.
1
WEEP HOLES IN LOW POINTS
OF LETTERS. (2) MIN. LISHT
SHIELD REQUIRED AT EA. HOLE.
.375" DIA. HARDWARE
-AS REQUIRED PER WALL
CONSTRUCTION.
SPLICE CONNECTOR
SECLPS-3 POWER
SUPPLY BEHIND WALL
(MUST BE SHIELDED FROM
THE ELEMENTS.)
- J-BOX with PRIMARY
ELECTRICAL (BY OTHERS)
Revised 9/30/04 KM
uc i i cis sc^ i iwrN-Kcriw i c ru wcis surru 2" = f-0"
3S" LETTERS and ABOVE
ue i i CK scu i luiVKsn v i c ru WEIS »urru 2' = r-o-
30" ond 24" LETTERS
MATERIAL LIST
X xxxxxxxxxx
Hilton
Corporate Office:
755 Crossover Lane
Memphis, Tennessee, 38117
3fl'-3"
24" CHANNEL LTRS
SELCORE TETRA RED-RED L.E.D. (5 PER FOOT)
TOTAL FT.: 3S'-3
TOTAL AMPS = 0.9 AMPS,
(1)120V.,20ACIR.
OA STRETCH = 13'-T (STRAIGHT LINE)
OA. STRETCH : S'-113/4" (STACKED)
L.E.D. DIAGRAM
MFR.(x) SET AS SHOWN
INSTALL PRIMARYOES) PER N.E.C.
U.L. LABELS REQUIREDINSTALL SIGNAGE PER N.E.C.
U.L. 21S1 COMPLIANT
SELCORE TETRA
RED-RED LE.D.
(5) PER FOOT.
" = T-O'
TETRA™ L.E.D.
ILLUMINATION
(PER SET) MATERIAL LIST
40'
1
1
•
SELCORE TETRA RED L.E.D. (5 PER FOOT)
(SECLPS-3 POWER SUPPLY
TRANSF. BOX.
END CAPS and SPLICE CONNECTORS
DRAWN 6-9-04
REVISED 4-4-05 JCH
REVISED 6-4-05 JCH
Hilton
Corporate Office:
755 Crossover Lane
Memphis, Tennessee, 38117
AS NEEDED
SIGN SPECIFICATIONS:
D/F INTERNALLY-ILLUMINATED .063" ALUMINUM
MONUMENT SIGN.
"HOMEWOOD SUITES" CABINET FILLER & RETAINER
SIDE PAINTED PMS 425 GREY. RETAINER FACE
PAINTED TO MATCH #3630-6949 TEAL GREEN VINYL.
(INSIDE OF CABINET TO BE PAINTED STARBRIGHT
LIGHT ENHANCING PAINT).
.150" WHITE LEXAN FACES TO HAVE VT-7201 TEAL
GREEN VINYL BACKGROUND w/ WEEDED
GRAPHICS TO BE SHOW-THRU WHITE.
"DUCK" & RULE TO HAVE #3630-131 METALLIC
GOLD VINYL APPLIED TO 1st SURFACE.
"HAMPTON INN" CABINET FILLER & RETAINER
PAINTED PMS 425 GREY.
.150" WHITE LEXAN FACES w/ 1st SURFACE
APPLIED VINYL:
BACKGROUND - VT1937 BLUE
OUTER BORDER - VT1936 RED
INNER BORDER - VT1935 GREY
CARTOUCHE - VT1935 GREY
COPY - SHOW-THRU WHITE
FABRICATED .063" ALUMINUM BASE & REVEAL TO
BE PAINTED TO MATCH PMS 425 GRAY.
SIGN INTERNALLY-ILLUMINATED w/ 800mA H.O.
FLUORESCENT LAMPS.
STEEL POLE SUPPORTS / FOUNDATION TO BE
DETERMINED BY ENGINEERING.
END VIEW
D/F MONUMENT SIGN
SCALE: 1"= 1'-0"
REVISION / DATE APPROVAL / DATE
£
WWW.
Chandler
Signs
chandlersigns.com
3201 Manor Way
Dallas.TX 75235
12106 Valliant Drive
San Antonio, IX 78216
RO. Box 43123
Louisville, Iff 40253
2I4-902-2OOO
Fax 2I4-902-2O44
210-349-3804
Fax 2IO-349-8724
502-489-3660
Fax 502-254-3843
750 E. Hwv. 24 - Bldg. 2. Ste. 200 719-687-2507
Woodland Park. CO 80863 Fax 719-687-2506
1335 Park Center Drive - Ste. 200 760-967-7003
Vista. CA 92081 Fax 760-967-7033
Tib drnirg bite property of Oumller Signs, Utind in rights
to to IB* for reproduction am fwerwdbf Chandler SgiB.L.P.
R1:10/26/05:JC: REVISED LAYOUT
R2:10/28/05:JC: REVISED LAYOUT
R3:11/04/05:JC: REVISED LAYOUT
R4:11/18/05:JC: REVISED SIGN
Client
Sales
Estimating
Art
Engineering
Landlord
Design # C55874R4 Sheet 3 of 4
Sales/Coordinator R. HANSON / R. KIRSCH
Designer J.CASTILLO Date 10/07/05
Client HAMPTON INN
Street YARROW DRIVE &
PALOMAR AIRPORT ROAD
FINAL ELECTRICAL
CONNECTION
BY CUSTOMER
City/State CARLSBAD, CA
12/9/2005
11:12AM
Structural Engineering Calculations for:
HAMPTON INN/HOMEWOOD SUITES
Carlsbad, CA
6' x 4' D/F Monument Sign
Index
Title 1
Specifications 2
Wind Loads 3
Supports 4
Footing 5
Prepared by:
Tom Holden, Technical Director
Chandler Signs, LP
1335 Park Center Drive, Suite B
Vista, CA 92081
Sheet 1 of 5
12/9/2005
11:12AM
SPECIFICATIONS
Project: HAMPTON INN/HOMEWOOD SUITES
Descript: 6' x 4' D/F Monument Sign
Steel...
Design and fabrication according to AISC-ASD, 9th edition.
Plate, angle, channel, tee and wide flange: ASTM A36.
Round pipe: ASTM A53 Grade B or equivalent.
Square and rectangular tube: ASTM A500 Grade B.
High strength bolts: ASTM A325, bearing type connections (snug tight).
Machine bolts: ASTM A307.
Anchor bolts or threaded rod: ASTM A36.
Steel for reinforced concrete: Grade 60.
Welding...
Design and fabrication according to AWS D1.1.
AWS certification required for all structural welders.
E70XX electrodes for SMAW processes.
F7X-EXXX electrodes for SAW processes.
Concrete...
Design and construction according to ACI 318-89, revised 1992.
Compressive strength at 28 days, fc= 2,500 psi minimum.
Concrete poured into constrained earth excavations must cure under proper
conditions for 4 days prior to sign box installation. ( Exception: if the overall height
of the sign is less than 20 feet and the sign pole is adequately braced against wind
loads for a minimum of 4 days, the box may be installed the same day as the
footing is poured.)
For pier and caisson footings, concrete must be poured against undisturbed earth.
Maintain a minimum 3" concrete cover over all embedded steel.
Sheet 2 of 5
12/9/2005
11:12AM
WIND & SEISMIC LOADS
Project: HAMPTON INN/HOMEWOOD SUITES
Descript: 6' x 4' D/F Monument Sign
Ref: Uniform Building Code 1994
Basic Wind Speed= 90
Exposure= c
Cq= 1.4
mph, UBC figure 16-1
flat terrain, generally open for 1/2 mile.
signs, flagpoles and lightpoles, UBC table 16-H
Calculation of Design Wind Pressures
Height (ft):(qs)(Ce)(Cq) = Wind Pressure
15
20
25
30
40
60
80
100
120
160
200
300
400
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
1.06
1.13
1.19
1.23
1.31
1.43
1.53
1.61
1.67
1.79
1.87
2.05
2.19
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
30.8
32.8
34.5
35.7
38.0
41.5
44.4
46.7
48.5
52.0
54.3
59.5
63.6
psf
psf
psf
psf
psf
psf
psf
psf
psf
psf
psf
psf
psf
Seismic Load Comparison
Seismic Zone= 1
Z= 0.1
l= 1.0
Cp= 2.0
Wp= 15.0
Fp= (Z)(l)(Cp)(Wp)= 2.3
UBC figure 16-2
standard structures
UBC table 16-P, signs
psf, typical sign box with structure
psf
Sheet 3 of 5
12/9/2005
11:12AM
COLUMN LOADS & DESIGN
Project: HAMPTON INN/HOMEWOOD SUITES
Descript: 6' x 4' D/F Monument Sign
Ref: Manual of Steel Construction, AISC 9th Edition
Areas Subject to Wind Forces
Section
1
2
3
4
5
6
7
8
Description
Sign Box #1
Height Width Centroid
Feet Feet (Feet)
643
Area
(sqft)
24.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Wind
Pressure,
psf
30.8
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Load
#
739
0
0
0
0
0
0
0
Total Load 739
Calculation of Design Forces at Critical Heights
y(ft)o.oo
M(#')V(#)
2,216 739
Calculation of Bending Stress in Supports
y(ft)
0
#0f
Supports
1
Support
Type
Steel Pipe
Tube
Width or
Diameter
3.5
Tube
Depth
(N/A for
pipe, rod)
Wall
Thickness
0.216
Allowable
Fb (ksi)
30.70
Sx Used
1.7241
Sx
Required
0.8660
Actual
Stress
(ksi)
15.42
Check
OK
Column
Type
Column
Size
Allowable Bending Stresses
Criteria Stress increase factor= 1.33
Steel Pipe 3.50 d/t <3300/Fy so... Fb= 0.66Fy= 30.7 ksi
Sheet 4 of 5
12/9/2005
11:12AM
LATERAL BEARING PIER AND CAISSON FOOTINGS
Project: HAMPTON INN/HOMEWOOD SUITES
Descript: 6'x 4'D/F Monument Sign
Ref: Uniform Building Code 1994 (Sec. 1806.7)
Round Pier Design
Top of Basic Lateral
Concrete Total Load Average Arm Moment per Load per Soil Stress Depth Used
Elevation # (feet) # of Piers Pier(#') Pier(#) (psf) (feet)
0 739 3.00 1
Diameter, b=
Minimum Depth, D= (A/2)(1+ SQR(1 + (4.36h)/A))=
S1=(q)(4/3)(2)(D/3)=
A=(2.34P)/(S1)(b)=
2,216 739 150 4.00
18.00 in, round augered hole
3.94 ft OK,< depth used
535 psf
2.15
Foundation Bearing Check
Allowable Bearing Pressure= 1,300 psf, 1994 UBC table 18-1-A, at grade
Approximate Sign Wt per pier=
Base Wt=
Projected Base Area=
q max=
123
1,060
1.8
670
OK
Ib
Ib
sqft
psf.soil
Reinforcement Check
Concrete compressive strength:
Max Tensile Stress (psi):
Min Steel for temp, shrinkage:
2,500 psi
46 <0.3Fc, No steel reinforcement required for bending
0.3563 sq in
Volume of Concrete per Footing=
Total Order Volume of Concrete=
Concrete Volume
0.26 cubic yards (+-) or
0.26 cubic yards (+-) or
7.07
7.07
cubic feet (+-)
cubic feet (+-)
Sheet 5 of 5
R A L O M A AIR f» O JR
181'-3" SETBACK TO CENTERLINE OF DRIVEWAY
2'-0" SETBACK FROM PROPERTY
LINE.
SITE PLAN
SCALE: 1/64" = 1'-0"
Chandler
Signs
3201 Manor Way 214-902-2000 750 E. Hwv. 14 - Bldg. 2, Ste. 200 719-687-2507
Dallai,IX 7S2JS Fax 2I4-9O2-2044 Woodland Park, CO S08« Fax 7I9-4S7-2506
12106 Valliant Drive 210-349-3804 I33S Park Center Drive - Ste. 200 760-967-7003
San Antonio. TX 78216 Fax 210-349-8724 Vista. CA 92081 Fax 760-967-7033
. .. . P.O. Box 43123 502-489-3660 Thij drawing b the property rf dundler Sigra, LR and »B rights
WWW.CnanaierSlgnS.COin Louisville, Kr 402S3 Fax 502-254-3843 tpbiatfarrepr<KluctionarartKn«ItyChai«»erSte».LP.
REVISION / DATE
R1:10/26/05:JC: REVISED LAYOUT
R2:10/28/05:JC: REVISED LAYOUT
R3:11/04/05:JC: REVISED LAYOUT
R4:11/18/05:JC: REVISED SIGNS
APPROVAL / DATE
Estimating
Art
Engineering
Design^ C55874R4 Sheet 4 of 4
Sales/Coordinator R. HANSON / R. KIRSCH
Designer J. CASTILLO Date 10/07/05
Client HAMPTON INN
Street
YARROW DRIVE &
PALOMAR AIRPORT ROAD
FINAL ELECTRICAL
CONNECTION
BY CUSTOMER
City/State CARLSBAD, CA