HomeMy WebLinkAboutPS 05-159; West Inn & Suites; Sign Permits/Programs (PS)City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-4610
PLANNING APPLICATION #
RECi'D BY /JzL,
DATE
SIGN FEE 4[
SIGN PROGRAM FEE.
RECEIPT NO.RECEIVED
REVIEW FOR SIGN PERMIT
Planning Department CITY OF CARLSBAD
All plans submitted for sign permits/sign programs shall consist of a minimul
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
NAME OF PROJECT: (AJJJ-f"
ADDRESS OF PROJECT:~t Q
ASSESSOR PARCEL NUMBER: g/D- QJ / - OJ
RELATED PLANNING CASE NUMBER(S): f>0f
TYPE OF DEVELOPMENT:
(a) Residential
(b) Commercial
(c) Office/Industrial
lolel/Motel
(e)
(f)
(g)
(h)
Service Station
Prof. Care
Theater
Govt/Church
(i) Public Park
(j) Produce Stand
(k) Nursery
(1) P-U/OSZone
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA
VILLAGE REDEVELOPMENT AREA YesQ
SIGN ORDINANCE:
COASTAL ZONE: Yes@"
Form 10 Revised 12/04
No
No
No
No
Specific Plan Number
C
Requires VR Approval
of
Page 1 of 4
EXISTING SIGNS:
TYPE y
Pole
Monument
Wall
Suspended
Directional
Canopy
Freestanding (Project Identity)
NUMBER SIGN AREA SIGN HEIGHT
PERMITS ISSUED FOR EXISTING SIGNS: Yes
PROPOSED PERMANENT SIGNS:
No Date
TYPE
Pole**
Monument**
Wall
Suspended
Directional
Canopy
Freestanding**
(Project
Identity)
MAXIMUM
NUMBER
ALLOWED
3
NUMBER
PROPOSED
£
MAXIMUM
SIGN
AREA
-ten ^
PROPOSED
SIGN
AREA
n*f.nv
MAXIMUM
SIGN
HEIGHT
frsfjto r*v(
saua^ ^
J/lJ S'Vio
PROPOSED
SIGN
HEIGHT
3'V>i"
t>'6"
PROPOSED TEMPORARY SIGNS:
TYPE
Construction**
For Sale**
Banner
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
f*Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for
potential sight distance and visibility issues. Additional information must supplement this application
showing how the proposed signage will not encroach into the public right-of-way or present a traffic
hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs.
Form 10 Revised 12/04 Page 2 of 4
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
TOTAL BUILDING STREET FRONTAGE Ht)4e(
TOTAL SIGNAGE ALLOWANCE \ LP/& £ -M*£
EXISTING SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AT PRESENT
PROPOSED SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN
ITERIA
Ht)4e( '• "1(0*- ""1" \f
1^.7 _
«
""] *f- ^ "7
\ • ft
-P
. sq. ft.
_ sq. ft.
. sq. ft.
. sq. ft.
. sq. ft.
OWNER APPLICANT
NAME (PRINT OR TYPE)NAME (PRINT OR TYPE)
MAILING DDRESS MAILING ADDRESS
CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHONE
I CERTIFY THAT I AM THE LEGAL OWNER AND THAT
ALL THE ABOVE INFORMATION IS TRUE AND
CORRECT TO THE BEST OF MY KNOWLEDGE.
SIGNATURE
I CERTIFY THAT I AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE INFORMA-
TION IS TRUE AND CORRECT TO THE BEST OF MY
KNOWLEDGE.
D^TEV /SIGNATURE DA
PLANNER CHECK LIST:
1 . Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: •> In right-of-way
•J* In visibility triangle at corner
5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner:Date:},£ )
Form 10 Revised 12/04 Page 4 of 4
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Traffic Engineering Department, which will not allow signs to be
approved over the counter. Additional time will be required for on-site inspection.
Show building Is
P/L
\ ..../.~ •i oi •
Show all prop erty lines ! JfP/L . •
i •i •
•
S
curb line •"
•
Sight Visibility
1
i
Sight Distance Requirem
1
1
how setbacks from all cu
l
1
1
1
Street Name(s)
1
i
ent
irbs
North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
Form 10 Revised 12/04 Page 3 of 4
City of Carlsbad
1635 Faraday Avenue Carlsbad CA 92008
Applicant: SWAIN SIGN
Description Amount
PS050159 .00
Not valid unless validated by Cash Register
PLEASE RETAIN RECEIPT FOR REFUNDS OR ADJUSTMENTS
Receipt Number: R0054579 Transaction ID: R0054579
Transaction Date: 12/21/2005
Pay Type Method Description Amount
Payment Check 13738 45.00
Transaction Amount: .00
(JOo RECEIVED
CVTY OF CARLSBAD
J1EPT
t
INN & SUITES
Carlsbad, California / Exterior Building Signage
S5
*•fH
-f-t
§
HFEDERAL
HEATH
S1GW COMPANY
Ol••-i
I
INN <Sc SUITES
Carlsbad, California / Exterior Building Signage
SIGNPE1RMITNO.PS
FEDERAL
HEATH
L.
DATE RECEIVED
DEC 2 12005
CITY OF CARLSBAD
PLANNING DEPT
SIGN COMPANY
CANNOJ ROAO
SITE PLAN
NOT TO SCALE
33.75 SQ.FT.
41.12 SQ.FT.
74.87 TOTAL SQ.FT.
FEDERAL
HEATH
SIGN COMPANY
www.FederalHeath.com
4602 North Avenue
Ocearuide, CA 92056
|760] 631-5050 Fax (760) 631 -5065
Other Office Locations:
Ocearaide - Los Angeles - Las Vegas
Tacoma - Kansas City - Willowbrook
Milwaukee - Euless - San Antonio
Atlanta - Tampa - Daytona Beach
Bunding Quality Slgnage For American Business
Revisions:
1-BW-Nov 9/05 - Delete sign "A3* from south elev.
2-BW-Dec 5/05 - Delete sign "A1" from north elev.
Account Rep: David Garner
Project Manager:
Drawn By: Brian W00(l
Project / Location:
West
Carlsbad, CA
Client Approval/Date:
Landlord Approval/Date:
This original drawing is provided as part of a
planned project and Is not to be exhibited, copied or
reproduced without the written permission of
Federal Heath Sign Company LLC or its
authorized agent.
Job Number:
File Name:
Date: Opt 1 0, 2005
Sheet Number: 1 Of 4
U Design Number 23-57173
1 0'-O"
3'-4 VST 4 6'-7 %"
6'-3 W
C\J
INN «Sc SUIT j
i
L33/8"r 51
MANUFACTURE & INSTALL 1 SET OF HALO-ILLUMINATED REVERSE CHANNEL LETTERS W/ LETTERBOX & INTERNALLY ILLUMINATED CHANNEL LOGO / 33.75 SQ.FT.
"West":
REVERSE CHANNEL LETTERS FABRICATED FROM ALUMINUM & PAINTED SATIN BLACK ON ALL EXTERIOR SURFACES.
LETTER RETURNS TO BE 31/2U DEER
INTERNAL WHITE NEON ILLUMINATION POWERED BY REMOTE TRANSFORMERS.
MOUNT LETTERS 1 W OFF OF FASCIA FOR HALO ILLUMINATION.
"INN & SUITES":
LETTERBOX TO BE FABRICATED FROM ALUMINUM & PAINTED SATIN BLACK ON ALL EXTERIOR SURFACES.
COPY TO BE ROUTED OUT AND IN-FILLED W/ 1/2n THICK, CLEAR ACRYLIC W/ 2500-20 WHITE VINYL APPLIED 1ST SURFACE.
INTERNAL ILLUMINATION PROVIDED BY WHITE NEON POWERED BY REMOTE TRANSFORMER.
LETTERBOX TO BE FLUSH MOUNTED TO FASCIA.
LOGO:
FACE TO BE FABRICATED FROM WHITE ACRYLIC W/ DIGITALLY PRINTED GRAPHIC APPLIED 1ST SURFACE.
RETURNS TO BE PRE-FINISHED SATIN BLACK ALUMINUM W/MATCHING TRIMCAR
INTERNAL ILLUMINATION PROVIDED BY WHITE NEON POWERED BY REMOTE TRANSFORMERS.
LOGO TO BE FLUSH MOUNTED TO FASCIA.
SCALE: 1" = 1'-0"
SIGNAGE AS SEEN AT NIGHT
SOUTH ELEVATION
SCALE : 1/32" = 1'-0"
FEDERAL
HEATH
SIGN COMPANY
www.FederalHeath.com
4602 North Avenue
Oceanslde, CA 92056
(760| 63! -5050 Fax (760) 631 -5065
Other Office Locations:
Oceanside - Los Angeles - Las Vegas
Tacoma - Kansas City - Wlllowbrook
Milwaukee - Euless - San Antonio
Atlanta - Tampa - Daytona Beach
Bunding Quality Slgnage For American Business
Revisions:
1-BW-Nov 9/05 - Revise sizes of "A1* & "AT &
delete sign "A3"
2-BW-Dec 5/Q5 - Increase size of "A2"
Account Rep. David Garner
nqiect Manager: Sandra Ramirez
Drawn By: Brian WOOd
Project / Location:
West
Carlsbad, CA
Client Approval/Date:
Landlord Approval/Date:
This original drawing is provided as part of a
planned project and is not to be exhibited, copied or
reproduced without the written permission of
Federal Heath Sign Company LLC or its
authorized agent.
Job Number:
Rle Name:
Date: OctIO, 2005
Sheet Number: 2 Of 4
Design Number: 23"57 173
35/8"INN & SUITE
SIGNAGE AS SEEN AT NIGHT
MANUFACTURE & INSTALL 1 SET OF HALO-ILLUMINATED REVERSE CHANNEL LETTERS W/ LETTERBOX & INTERNALLY ILLUMINATED CHANNEL LOGO / 41.12 SQ.FT.
"West":
REVERSE CHANNEL LETTERS FABRICATED FROM ALUMINUM & PAINTED SATIN BLACK ON ALL EXTERIOR SURFACES.
LETTER RETURNS TO BE 3 V4" DEER
INTERNAL WHITE NEON ILLUMINATION POWERED BY REMOTE TRANSFORMERS.
MOUNT LETTERS 1 W OFF OF FASCIA FOR HALO ILLUMINATION.
"INN & SUITES":
LETTERBOX TO BE FABRICATED FROM ALUMINUM & PAINTED SATIN BLACK ON ALL EXTERIOR SURFACES.
COPY TO BE ROUTED OUT AND IN-FILLED W/V4" THICK, CLEAR ACRYLIC W/ 2500-20 WHITE VINYL APPLIED 1ST SURFACE.
INTERNAL ILLUMINATION PROVIDED BY WHITE NEON POWERED BY REMOTE TRANSFORMER.
LETTERBOX TO BE FLUSH MOUNTED TO FASCIA.
LOGO:
FACE TO BE FABRICATED FROM WHITE ACRYLIC W/ DIGITALLY PRINTED GRAPHIC APPLIED 1ST SURFACE.
RETURNS TO BE PRE-FINISHED SATIN BLACK ALUMINUM W/ MATCHING TRIMCAR
INTERNAL ILLUMINATION PROVIDED BY WHITE NEON POWERED BY REMOTE TRANSFORMERS.
LOGO TO BE FLUSH MOUNTED TO FASCIA.
SCALE :1"=1'-0"
EAST ELEVATION
SCALE : 1/32" = 1'-0"
FEDERAL
HEATH
SIGN COMPANY
www.FederalHeath.com
4602 North Avenue
Oceanslde, CA 92056
[7601631-5050 Fax (760) 631-5065
Other Office Locations:
Oceanside - Los Angeles - Las Wegas
Tacoma - Kansas City - Wltlowbroc*
Milwaukee - Euless - San Antonio
Atlanta - Tampa - Daytona Beach
Building Quality Slgnage For American Business
Revisions:
1-BW-Nov 9/05 - Revise sizes of "A1" & "A2" S
delete sign "A3"
2-BW-Dec 5/05 - Increase size of "A4"
Account Rep. David Garner
project Manager. Sandra Ramirez
prawn By Brian Wood
Project / Location:
West
Carlsbad, CA
Ciient Approval/Date:
Landlord Approval/Date:
This original drawing is provided as part of a
planned project and is not to be exhibited, copied or
reproduced without the written permission of
Federal Heath Sign Company LLC or its
authorized agent.
Job Number:
file Name:
Date: Oct 1 0, 2005
Sheet Number: 3 Of 4
Design Number 23-57 173
1 %" MIN. SPACERS
OFF WALL
PAINT INSIDE
OF LETTER WHITE
1 3/4" TUBE SUPPORT
(TYP)
ELECTROBITS
ELECTRODE BOOT
NEON TUBING
3/16" CLEAR
POLYCARBONATE BACK
ELECTROBITS
ELECTRODE BOOT
1/2-LIQUIDTITE
CONNECTOR
LETTER TO
LETTER JUMP
'/z-EMTORFLEX
CONDUIT
TRANSFORMER
BOX
SGFP NEON
TRANSFORMER(S)
EXIST. WAtt
NOTES:
ALUMINUM FACE& LETTER RETURN
1 - All seams to be placed for min. visibility.
2- Install to conform w/ section 600 of NEC.
3- Letters fabricated to UL standards.
4- Transformer mounting TBD. in field.
5- Letters to be const, to prevent light leaks.
6- Min. 2 mounting bolts per letter.
DISCONNECT
SWITCH
(1 PER CIRCUIT)
EXISTING
ELECTRICAL
PANEL
J-BOX
(BY OTHERS)
BRANCH CIRCUIT(S) (BY OTHERS)
FOR SIGN
See notes for requirements
[HiHiiiuii^imiiiituiiimuiuii^/iimiiiiiiiiiuiiiiimiiiiiniBiiiiiiiiiu
DETAIL FOR TYPICAL REVERSE CHANNEL LETTER ("West")
Branch Circuit: NOT TO SCALE
A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit).
B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment,
c. Properly sized ground wire that can be traced back to the breaker panel must be provided.
D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement.
1 3/4" TUBE SUPPORT
(TYP)
3/16° ACRYLIC WITH
PLASTIC RETAINER
ELECTROBITS
ELECTRODE BOOT
NEON TUBING
.063 ALUM. BACK
ELECTROBITS
ELECTRODE BOOT
LETTER TO
LETTER JUMR
y/EMTORFLEX
CONDUIT
TRANSFORMER
BOX
SGFP NEON
TRANSFORMER(S)
1/2' NIPPLE WITH
BUSHING
.040 ALUM. RETURNS
YV WEEP HOLES
(2 MIN.)
EXIST. WALL
NOTES:
DISCONNECT
SWITCH
(1 PER CIRCUIT)
EXISTING
ELECTRICAL
PANEL
J-BOX
(BY OTHERS)
BRANCH CIRCUIT(S) (BY OTHERS)
FOR SIGN
See notes for requirements
1- All seams to be placed for min. visibility.
2- Install to conform w/ section 600 of NEC.
3- Letters fabricated to UL standards.
4- Transformer mounting TBD. in field.
5- Letters to be const, to prevent light leaks.
6- Min. 2 mounting bolts per letter.
DETAIL FOR TYPICAL CHANNEL LETTER WITH ILLUMINATED PLEX FACE (LOGO)
Branch Circuit: NOT TO SCALE
A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit).
B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment,
c. Properly sized ground wire that can be traced back to the breaker panel must be provided.
D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement.
FEDERAL
HEATH
SIGN COMPANY
www.FederalHeath.com
4602 North Avenue
Oceamlde, CA 92056
|760| 631 -5050 Fax (7601 631 -5065
Other Office Locations:
Oceanside - Los Angeles - Las Vegas
Tacoma - Kansas City - Willow/brook
Milwaukee - Euless - San Antonio
Atlanta - Tampa - Daytona Beach
Building Quality Sgrtage For American Business
Revisions:
Account Rep: David Garner
project Manager Sandra Ramirez
prawn By. Brian Wood
Project / Location:
West
Carlsbad, CA
Client Approval/Date:
Landlord Approval/Date:
This original drawing is provided as pan of a
planned project and is not to be exhibited, copied or
reproduced without the written permission of
Federal Heath Sign Company LLC or its
authorized agent.
Job Number:
File Name:
Date: Oct 1 0, 2005
Sheet Number:4 of 4
Design Number: 23-571 73