Loading...
HomeMy WebLinkAboutPS 05-163; Citifinancial; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760)602-4610 PLANNIN REC'D B DATE/ SIGN FEE SIGN PROGRAM FEE RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: I AjQ^ \\ \ ADDRESS OF PROJECT:'A ASSESSOR PARCEL NUMBER:-"77 RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential c) Office/Industrial (d) Hotel/Motel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesQ VILLAGE REDEVELOPMENT AREA YesQ SIGN ORDINANCE: YesQ COASTAL ZONE: YesQ «»«»««••««»«•»»«•« Form 10 Revised 12/04 (e) (f) (g) (h) Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone No D NO n NO n NO n Specific Plan Number . Requires VR Approval Page 1 of4 EXISTING SIGNS: TYPE Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) NUMBER SIGN AREA SIGN HEIGHT PERMITS ISSUED FOR EXISTING SIGNS: Yes PROPOSED PERMANENT SIGNS: No Date TYPE Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) MAXIMUM NUMBER ALLOWED NUMBER PROPOSED 1 MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT tq" PROPOSED TEMPORARY SIGNS: TYPE Construction** For Sale** Banner MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Form 10 Revised 12/04 Page 2 of4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building /s Show all prop erty line s P/L \ J i • i /*. ; / i / / • > S curb line •* Sight Visibility 1 Sight Distance Requiren 1 1 how setbacks from all cu i 1 1 1 Street Name(s) 1 i ent irbs North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. Form 10 Revised 12/04 Page 3 of4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. . sq. ft. . sq. ft. sq. ft. sq. ft. sq. ft. OWNER APPLICANT NAME (PRINT OR TYPE)NAME (PRINT OR TYPE) MAILING ADDRESS CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP TELEPHO I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE SIGNATURE DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •> In right-of-way •J* In visibility triangle at corner 5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: Form 10 Revised 12/04 Page 4 of4 12/29/2035 15:07 4104790237 Dec-13-35 14)29 Freu-HUGWS INVESMNTS MULHOLLAND HARPER PA<^ 04/05 W8TSMS31 T-9Ti P,34/38 F-822 citifinancial Ofljt 5, F rDO.. C<MtHM"**i* >APPROVED Q APPROVED AS NOTED. RESUBMIT, CORRECT A&NOTED. INVESTMENTS C...O.-..,,,-.-. 26i!4 A b (; C..- , CA __12/29/2005 15:07 <U04790207 Dsc-U-05 14:i8 FrenrHUGHES MULHOLLAND HARPER RAGE 02/05 t94»7598531 T-97Z P-M/M P-822 citifinancial .12/29/2005 15:07 4104790207 9BS-I3-OB 14:21 FrrarHUSKES INVESTMENTS citi financial APPROVED Date APPROVED AS NOTED. Q RESUBM1T, COBfl MLLHOLLAND HARPER PAGE 01/05 r-orc is pHo-fco shows •the new store front. citifinancial CITIFINANC'.AL RFLPCATlr>N Photo Number Typo N.~ ?;,„„ i Height 36" Width 14' - SulM S.,. F« Overall Height OQL I—I i yton/ Monument U Directional I I Channel Letters I I Olngle Tocc '—I Illuminated D Wall Mo^nt D Vlny, • Othor L-i Double Face I Non-1 llumlna ted Comments I Kis..| the too el* In »teen* Photo Numbor _QQ2 Type J9! Width 11' 0-1/4" So, Ft 1413 Overall Height Pylon/Monun^ent Directional Channel Letters lluminated a D (Wr I—I Double I ace Q Non-Illuminated Oommcnt * it.ifinancial " New Branch 2624 - A El Camlno R—mulholland harper company 18"P< APPROVED Date Q APPROVED AS NOTED. 0 flESUBMIUORRECTft NOTED."*tffr<&%ggy HUCMS INVESTMENrS «thj£5lii«d hireir camp Citifuuincial Carlsbad, CA Raceway Mounted Channel Loiters FRONT VIEW tkawlngScal* Not to scats inK> in f2<2«« BEJfTtEPL6M » a:LU <E Q d (NCSDenr- G> \r> inCD K a - DAVIS 8 8 - SBPEBCUn C - KARA1E SnifllU 0 - TRAVEL HLUSt__JiUJi.DJiinc ]jf|_'^p id Laates cn CM HH o o WHITE DAY AND WHITE AT NIGHT DIMENSION TABLE 16" 18" 21" 24" 2'-0" 2'-l 5/8" 2'-5" 3'-2 1/2' 13'-2E/B' 16'-5 1/8" 17'-7 1/2' 71/2" 10 1/2' 12' Z 1/8' 21/4' 21/2" 31/2" 33/8" 35/0' 43/4" 51/2' 27" 3'-7 1/2' 1?'-1Q' T-1 1/2' 315/16" 63/16" 2X3 7/8" 121/4" 3'-l 1/3" 8' 5" 71.90 V-3 1/2" l'-4 1/2" r-6 1/2" l'-9 5/8" 2'O 3/4' 63/4" 7 3/16' 8 1/8" 91/2" 10 7/6" l'-8 5/8" V-10' 2'-03/4" 2'-9"5' mulholland harper company 24776 Meeting House Joad Po«0!IK»BoxC Dor/on, MaiylaKl 21625-COT8 Totaphnne: (410) 47M300(EOO) 99S-3062 i (410) 479-0207 CltlFlnanclal 14.13 22.04 25.09 31.93 43.7 56.54 RACEWAY MOUNT CHANNEL LETTERS FACES FACE UECOBAT10N CHANNEL LETTER COLOR SPECIFICATIONS IBANSFOKMEBS Acamrrs»ois-a WHITE SCOTCHCAL }U 1230-43 TOMATO BED VINYL OVHttAY .050 ALUMINUM. PMS 485 USD .063 ALUMINUM, PMS 4B5 HED RED r JEWEUTE ACRYlim* 015-2 WHITB 3M BLUB PEBFOBATBD VINYL (COLOR TO EE DETEIMINEU) .050 ALUMINUM TO MATCH PMS 288 BLUE .063 ALUMINUM TO MATCH PMS 289 SLUE DK. BLUE T JEWUTE ACHYWTB1D16-2 WHITE .050 ALUMINUM COLOK WHITE .063 ALUMINUM C010E WHITE WHITE 1'JEWEIITE 30 M.A. 6500 WHITE 120 VOLT. 30 M.A. SMART SEBIES UL 2161 1/4' DIAMETER HOLE MQJ PES LETTER STIOKE COLOR TO MATCH FASCIA BA.\'U (AS CLOSE AS POSSIBLE) OK AS PER UNDLOB1) SEN CRHEHIA NON-FERROUS AS REQUIRED f\ luminum raceway painted to match fascia n/lounting angle is built in to raceway J/O Stainless Steel Threaded Rod Z x Z x 7/4 Anglo I ron strips to span studs onC. I r^> surfaces all thickness varies per location mulholland harper oompnny 24778 MEETINOHOUSE ROAD POST OPHOB BOX 0DENTON, MARYLAND Z1S29-02J8 TELEPHONE: <410) 479-1JOO FAX: (410) 479-0207 Vjenerlc Ixaceway Mounting Detail Raceway Mounted Channel Letters FRONT VIEW Drawing Scale: Not to scale DATE: 11/2/05 PAGE: 1of 1 «2620R CEIfflf DENTW. 2SE08 PLAZA Si CLEANEAS il to - DAVIS I IWWIEL OPTBBEM i 8 - SkJPEflC'JTS j C - KA8ATI SFWMByf 0 ~ TRAVEt PtUSc—s—ma fttftcs wiua-J2610 FC CLUE 12612-2616 FiTSESS EL 7E #26C4A RUBIO'S jPropoaals / Negofiations .easas CXrt fo? SignatureCWJTAL 8ft«K QF K0RTH C