Loading...
HomeMy WebLinkAboutPS 06-08; Staples; Sign Permits/Programs (PS)City of Carlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING APPLICATION # REC'D BY <J<L0 ' DATE I — ( <? - SIGN FEE SIGN PROGRAM FEE _ RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: ADDRESS OF PROJECT: ASSESSOR PARCEL NUMBER:: L&\- D&( '~®\ °°&F RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential (•bT'Commercial (c) Office/Industrial (d) Hotel/Motel (e) (f) (g) (h) Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes VILLAGE REDEVELOPMENT AREA YesQ SIGN ORDINANCE: YesfJ COASTAL ZONE: YesQ Form 10 Revised 12/04 No No No NO Specific Plan Number Requires VR Approval Page 1 of 4 EXISTING SIGNS: TYPE Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) NUMBER 1 f SIGN AREA ^ ill fwkfcJT SIGN HEIGHT <£' i -p /•-— j.O — ^ PERMITS ISSUED FOR EXISTING SIGNS: Yes PROPOSED PERMANENT SIGNS: No Date TYPE Pole** Monument** Wall Suspended Directional Canopy Freestanding** (Project Identity) MAXIMUM NUMBER ALLOWED NUMBER PROPOSED / MAXIMUM SIGN AREA PROPOSED SIGN AREA 4d.ig MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT •3f PROPOSED TEMPORARY SIGNS: TYPE Construction** For Sale** Banner MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. Form 10 Revised 12/04 Page 2 of 4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building /s P/L \ / i / Show all property lines | ; i •, •i • / S curb line •* 1 i Siglit Distance Requirem 1 1 how setbacks from all cu l 1 1 -'Srafb"Q^SS^ Siglit Visibility Street Name(s) 1 i ent trbs Q North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. Form 10 Revised 12/04 Page 3 of 4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. sq. ft. sq. ft. sq. ft. sq. ft. sq. ft. OWNER NAME (PRINT OR TYPE) MAILING ADDRESS CITY AND STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. L$-^\&^£ LA-^^JL/ SIGNATURE \ DATE APPLICANT NAME (PRINT OR TYPE) MAILING ADDRESS ^2.6"11 1>LU£ ST^V^. CITY AND STATE ZIP TELEPHONE I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •> In right-of-way *J« In visibility triangle at corner 5. Pole and monument signs to be checked by Traffic Engineering, for visibility issues. 6. When approved route copy to Data Ento APPROVED: Planner:Date: Form 10 Revised 12/04 Page 4 of 4 City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 Applicant: CSG CORP Description Amount PS060008 45.00 Receipt Number: R0054997 Transaction ID: R0054997 Transaction Date: 01/18/2006 Pay Type Method Description Amount Payment Check 7422 45.00 Transaction Amount: 45.00 THE SIGN ORDINANCE (TABLE B) ALLOWS ONLY ONE (1) SIGN PER BUILDING OR TENANT ALL SIGN LOCATIONS WERE PICKED AT RANDOM. FINAL LOCATIONS TO BE DETERMINED BY OWNER/LANDLORD. - Letters may be either illuminated or non-illuminated standard five (5) inch thick channel letters, or three (3) inch deep reverse letters, fabricated out of aluminum, or 3/4" Sintra® letters if non-illuminated. - Each tenant will be permitted only one (1) sign. The sign shall be positioned at a single location as shown on this exhibit. = PROJECT ENTRY MONUMENT SIGNS = AUTO DIRECTIONAL 20.000 S.F. Retail GBOUP M OCCUR Vicinity Map VICINITY MAP & SITE PLAN AUTO DIRECTIONAL SIGN'B' PROJECT MONUMENT 'A'AUTO DIRECTIONAL SIGN'A PROPOSED 3 FT. "STAPLES" REVERSE ILLUMINATED CHANNEL LETTERS - SSGN A SCALE: 1/2" = 1'-0" ONE(1) SET REQUIRED COLOR & MATERIAL SCHEDULE LETTERS: FACES & RETURNS: 3" DEEP FABRICATED ALUMINUM CHANNEL LETTERS PAINTED WHITE. BACKS: CLEAR LEXAN. LIGHTING: INTERNAL 8300° WHITE NEON, REVERSE ILLUMINATION. BACK PANEL: ALUMINUM PANEL 1" LARGER BEYOND LETTER. TRANSFORMERS: TO BE VERIFIED 46.1 87 SO. FT. \ AI i livyilKII llVfl DAPl^ALUMINUM L5AUr\ ' 1" BEYOND SQUARE FOOTAGE: ALLOWED: 50.00 PROPOSED: "STAPLES" LETTERS: 46.187 « ^5 j> O S5 Q ;° FT. .FT. ^\ <xj iAPPROVED BYI §ia i 33 ? ! i i 155'-9" JVOTE: RED TILE BACKGROUND BY OTHERS 40" KNEE WALL BOLLARDS EXHIBIT E1 (1 OF 1) RED ALUMINUM STORE-FRONT MULLIONS FRONT/SOUTH ELEVATION SCALE: 1/16" = 1' STAPLES Facility Identification Program Location: Carlsbad Kieffer IHI IS «N Clltlllll IINFI1USHEO WUIK SIlUiniD 101 M11 (OHiaiH «I1H 1noiia IEINS mm foi von 11 utm i a we. u 'i HOI TO IE traDiico, win01 umiin! i« <«r Ftiaioi minim HI »tnrc> m«iiiio< 01 IILIFB i <o. i«c B52347 IS ZOOS KIEFFEU St CO- INC. 585 Bond Street Lincolnshire, IL 60069 PHONE: (847) 520-1255 FAX: (847) 520-1543 FIELD SURVEY REQUIRED BEFORE MANUFACTURE 1 '-6" "STAPLES" MONUMENT PANEL W/ ROUTED-OUT BACKED-UP COPY - SIGN B SCALE: 3/4" = 1 '-0" COLOR & MATERIAL SCHEDULE PANEL: ALUMINUM PANEL WITH ROUTED-OUT "STAPLES" LETTERS. BACKGROUND PAINTED TO MATCH 3M #3630-53 CARDINAL RED VINYL. "STAPLES" COPY: "STAPLES" TO BE BACKED UP WHITEACRYLIC. NOTE: "STAPLES" MONUMENT CABINET SECTION TO BE PAINTED TO MATCH 3M #3630-53 CARDINAL RED VINYL. VERIFY ALL MEASUREMENTS BEFORE MANUFACTURE TWQ(2) PANELS REQUIRED 5'-0" STAPLES 2'-0" it, I PROPOSED "STAPLES" PANEL ON D/F MONUMENT SIGN EXHIBIT E2 (1 OF 1) SCALE:3/8" = 1'-0" STAPLES Station Program Location: Carlsbad, CA ACCOUNT: STAPLES LOCATION: Carlsbad. CA ACCT.REP. L.C. REVISION: A A- OATE: 11/17/05 DESIGNER:JMAK_ aLa A Kfefffer B52347A THIS IS IN OIKIIM UK WISHED 1UMISSliltlTTED 101 J',l II (OHHIIIS KITH IniiKi iw rum 101 vn iv KIEFIEI i en. inc. IT is HOI TO IE unman, WIED 01 raillED IN INT ttSHIOI WTH1UTT1E VliniN PltSISilOl Of Ill-ffI IM. lie C ZOOS KIEFFEH & CO. INC? 585 Bond Street Lincolnshire, IL 60069 PHONE; (847) 520-1255 FAX: (847) 520-1543 1 1/2"1/4" LAG SCREWS IN SHIELDS OR TOGGLE-BOLTS AS NEEDED (TYR) (MIN. FOUR(4) PER LETTER) ANGLE CLIP TO LEXAN BACK .090 (MIN.) ALUMINUM LETTER RETURN NEON SUPPORT 15 mm NEON LEXAN BACK G-CUP OR ELECTROBITS BOOT GTO WIRE TO TRANSFORMER PASSTHRU CONDUIT GROUNDED METAL TRANSFORMER BOX DISCONNECT SWITCH 277 VOLT REMOTE TRANSFORMER (TO BE VERIFIED) 1/4" WEEP HOLES AS NEEDED ALUMINUM BACKER PANEL 1" BEYOND LETTER CONDUIT TO PRIMARY SOURCE WALL TYPICAL U. L. APPROVED REVERSE ILLUMINATED LETTER SECTION SCALE: 1 1/2" = 1 '-0" i -. i SIGN(S) TO BE MANUFACTURED TO U.L. SPECIFICATIONS AND WILL BEAR THE U.L. LABEL(S). INSTALL IN ACCORDANCE WITH NATIONAL ELECTRICAL CODES. Facility Identification Program Location: Carlsbad, CA IMS B111 BIIEWil IINim OUMIE SUUIIITtD 101 IIS! in (OHKIiON Will J Html IMS PUTO101VIIII IIEEFEI t (9. IK. II IS NOT TO I! ««UCE1, WIGoi Biiin» IK m Him* romn TII wumi Mission 01 iiiffin > (o. INC. 2OO5 KIEFFEFt 8r CO. INC. 585 Bond Street Lincolnshire, IL 60069 PHONE: (847) 520-1255 FAX: (847) 520-1543 1 - — — ~ — — (B Undeveloped Parcel ^ \ \ ^~ k^CVVlA^^-^Al^' \j>L^ac^Crv\^ — I I; MT> \^^\^c^*& WA^) **- (-&-<>& <, I i SITE PLAN NOT TO SCALE STAPLES Station Program Location: Carlsbad, CA Kfefffer B52347C THIS IS All CllfilNM UKMIBIISHtO BmVUG SUIUiniD FOIUM III (ONHEniBN WITH Anoun IEIHE mm loiygg <.i «um i a.»,(. n« HOT TO i! miwm, (oriED01 mniim IN ANT FAiiiiimiiiBiuiniii nmm HUIHIOI OFIIFJIKitojii. C ZOOS KIEFFER S. CO. INC. S85 Bond Street Lincolnshire, IL 60069 PHONE: (847) 520-1255 FAX: (847) 520-1543