HomeMy WebLinkAboutPS 06-60; Regents Bank; Sign Permits/Programs (PS)City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-4610
PLANNED
REC'DB
DATE
SIGN FEE _
SIGN PROGRAM FEE
RECEIPT NO.
REVIEW FOR SIGN PERMIT
Planning Department
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks
NAME OF PROJECT:
ADDRESS OF PROJECT:NIL
ASSESSOR PARCEL NUMBER:2i \ Q~ O ^ N
RELATED PLANNING CASE NUMBER(S):
f?PE OF DEVELOPMENT:
(a) Residential
(b) Commercial
(c) Office/Industrial
(d) Hotel/Motel
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA YesQ
VILLAGE REDEVELOPMENT AREA YesQ
SIGN ORDINANCE: YesQ
COASTAL ZONE: YesQ
Form 10 Revised 12/04
(e)
0)
(g)
(h)
Service Station
Prof. Care
Theater
Govt/Church
(i) Public Park
(j) Produce Stand
(k) Nursery
(1) P-U/OSZone
No
NO
NO
NO
Specific Plan Number
Requires VR Approval
Page 1 of 4
TYPE
Pole
Monument
Wall
Suspended
Directional
Canopy
Freestanding (Project Identity)
INUMBER^
^ , **«*•':>
* it' • *"*
SIGN AREA SIGN HEIGHT
PERMITS ISSUED FOR EXISTING SIGNS: Yes
PROPOSED PERMANENT SIGNS:
No Date
TYPE
Pole**
Monument**
Wall
Suspended
Directional
Canopy
Freestanding* *
(Project
Identity)
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
f
1
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
H *
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
PROPOSED TEMPORARY SIGNS:
TYPE
Construction**
For Sale**
Banner
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
*, fc
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for
potential sight distance and visibility issues. Additional information must supplement this application
showing how the proposed signage will not encroach into the public right-of-way or present a traffic
hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs.
Form 10 Revised 12/04 Page 2 of 4
SITE PLAN REQUIREMENT FOR POLE. MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Traffic Engineering Department, which will not allow signs to be
approved over the counter. Additional time will be required for on-site inspection.
Showbuihling/s
P/L
\.J-i ;i •
Show all property lines [ •
i •
i •
•
*•
S
curb hne •*
-*i~-
Siglit Visibilitj'
1
i
Siglit Distance Requirem
' »' - *
how setbacks from all cu
i
1
1
Street Name(s)
1
i
ent
Vr, <-s
irbs
North
r^*
21.41.080 Sign design standards
fv.
Relationship to S'treets: Signs shall be designed and located so as nbt'to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
Form 10 Revised 12/04 Page 3 of 4
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
TOTAL BUILDING STREET FRONTAGE *
TOTAL SIGNAGE ALLOWANCE
EXISTING SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AT PRESENT
PROPOSED SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN
ft.
. sq. ft.
_ sq. ft.
. sq. ft.
sq. ft.
. sq. ft.
OWNER
NAME (PRINT OR TYPE)
5€e attacked
MAILING ADDRESS
CITY AND STATE ZIP TELEPHONE
I CERTIFY THAT I AM THE LEGAL OWNER AND THAT
ALL THE ABOVE INFORMATION IS TRUE AND
CORRECT TO THE BEST OF MY KNOWLEDGE.
SIGNATURE . DATE
APPLICANT
NAME (PRINT OR TYPE)
-}t>ry "Allegro
MAILING ADDRESS
wt klL 4-c < xi - w-nt
CITY AND STATE ZIP TELEPHONE
Jfe. /?y CA ?;?/?-?
I CERTIFY THAT I AM THE REPRESENTATIVE OF THE
LEGAL OWNER AND THAT ALL THE ABOVE INFORMA-
TION IS TRUE AND CORRECT TO THE BEST OF MY
KNOWLEDGE.
/ ^ ' ?-// tf// / ^-^ '^ H*
SldflforfURE ^-- DATE
PLANNER CHECK LIST:
1.
2.
3.
4.
5.
6.
Field check by planner.
Within maximum length, area.
Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
Location: «> In right-of-way
»J* In visibility triangle at corner
Pole and monument signs to be checked by Traffic Engineering, for visibility issues.
When approved route copy to Data Entry
APPROVED: Planner:Date:,
«««««*««»
Form 10 Revised 12/04 Page 4 of 4
City of Carlsbad
1635 Faraday Avenue Carlsbad CA 92008
Applicant: ULTRASIGNS
Description Amount
PS060060 45.00
Not valid unless validated by Cash Register
PLEASE RETAIN RECEIPT FOR REFUNDS OR ADJUSTMENTS
Receipt Number: R0056144 Transaction ID: R0056144
Transaction Date: 03/16/2006
Pay Type Method Description Amount
Payment Check 45.00
Transaction Amount: 45.00
December 13, 2005
Mr. Ron Green
Ultra Signs, Inc.
9025 Balboa Avenue, Ste #150
San Diego, Ca. 92123
Re: Regents Bank Signage Package
Plaza I - 1921 Palomar Oaks Way, Carlsbad, CA.
To Whom It May Concern:
We the Landlord (Prentiss Properties) of the above-mentioned property, hereby approve
Ultra Signs to proceed with procuring signage permits for Regents Bank.
Please feel free to contact me should you have any questions.
Regards,
PRENTISS PROPERTIES ACQUISITION PARTNERS, L.P.
Kiffibcrl> D. Sabre, RPA
Property Manager
PRENTISS PROPERTIES
705 PALOMAR AIRPORT ROAD, SUITE 320 CARLSBAD, CALIFORNIA 92011
760438-4242 FAX: 760438-0046
18'-3
2'-8"
SECTION A SECTION B
AMK r-41/4"
NEW SINGLE FACED INTERNALLY ILLUMINATED WALL DISPLAY
SCALE 1/2"=1'-0"
USE STANDARD ALUMINUM CONSTRUCTION WITH MATTHEWS SATIN ACRYLIC POLYURETHANE FINISH,
SYMBOL USE REVERSE PAN CHANNEL CONSTRUCTION WITH THROUGH FACE AND HALO ILLUMINATION,
ROUTE OUT AND PUSH THROUGH GOLD COLORED GRAPHICS, USE TRANSLUCENT GOLD VINYL OVERLAYS,
PAINT SYMBOL FACE PER COLOR LEGEND BELOW, RETURNS GREEN PMS #342C,
LETTERS USE REVERSE PAN CHANNEL CONSTRUCTION WITH LED HALO ILLUMINATION,
PAINT LETTER FACES AND RETURNS BLUE PMS #288C,
ILLUMINATE ALL GRAPHICS WITH WHITE LED'S,
VERIFY EXACT TRANSFORMER LOCATION PRIOR TO INSTALLATION.
MAPT/M BLUE PMS #288C
MAPT/M GREEN PMS #342C
MAPT/M GOLD PMS#117C
MAPT/M REDPMS#187C
POWER SUPPLY
1/2" PVC SLEEVES
.063 ALUMINUM RETURNS
WELDED AT SEAMS
1/4" TOGGLE OR EQUIV
MINIMUM THREE PER LETTER
1/2" ON CENTER LED LOW VOLTAGE LIGHTING
USE ONE ROW PER 5" OF LETTER WIDTH
PUSH THROUGH PLEX GRAPHICS
HEYCO STRAIN RELIEF BUSHING
1/8" WHITE LEXAN
.090 ALUMINUM FACE
DRAINAGE HOLE WITH LIGHT BAFFLE
WALL
GROUNDED POWER CORD
POWER SUPPLY
1/2" PVC SLEEVES
.063 ALUMINUM RETURNS
WELDED AT SEAMS
23/4'13/8"
CLASS TWO CIRCUITS UP TO THREE REGULATORS PER CIRCUIT
POWER SUPPLY
LEADS FROM OTHER LETTERS
REGULATOR
OUTLET FOR ADDITIONAL
REGULATORS
DAISY CHAIN UP TO
THREE PER CIRCUIT
SECTION A
REVERSE PAN CHANNEL
WITH LED ILLUMINATION
THROUGH FACE AND HALO
PUSH THROUGH GRAPHICS
SIGN TO BE UL APPROVED AND BEAR UL LABEL
1/4" TOGGLE OR EQUIV
MINIMUM THREE PER LETTER
1/2" ON CENTER LED LOW VOLTAGE LIGHTING
USE ONE ROW PER 5" OF LETTER WIDTH
HEYCO STRAIN RELIEF BUSHING
1/8" WHITE LEXAN
.090 ALUMINUM FACE
DRAINAGE HOLE WITH LIGHT BAFFLE
WALL
PLANNING
BUILDING
"/ ~-~™ ~
APPROVED BY
3u^ cVy/^DATE
^^^ _ ^^^5- / 4> ** z>
j
GROUNDED POWER CORD
CLASS TWO CIRCUITS UP TO THREE REGULATORS PER CIRCUIT
POWER SUPPLY
LEADS FROM OTHER LETTERS
REGULATOR
OUTLET FOR ADDITIONAL
REGULATORS
DAISY CHAIN UP TO
THREE PER CIRCUIT
JOB INFORMATION
REGENTS BANK
1921 PALOMAR OAKS WY
CARLSBAD, CA
SALESPERSON
RON BREEN
DESIGNER
DAVID GREEN
SKETCH NO
REGENTS01
DATE
11-03-2005
REVISION DATES
<3> 11 -04-2005 DAG
® 11-30-2005 DAG
<D 12-05-2005 DAG
<3>
<§>
VOLTAGE
120 VOLTS
PRIMARY ELECTRICAL
TO SIGN LOCATIONS IS TO BE
PROVIDED BY OTHERS.
A 20 AMP DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS
AND A GROUND RETURNING TO
THE PANa IS REQUIRED FOR
ALL INSTALLATIONS.
COLORS REPRESENTED
IN THIS DRAWING ARE FOR
PRESENTATION PURPOSES ONLY.
THEY WILL NOT MATCH YOUR
FINISHED PRODUCT PERFECTLY
COLOR CALLOUTS ARE FOR A
MATCH AS CLOSE AS POSSIBLE.
THIS ORIGINAL DESIGN IS THE
SOLE PROPERTY OF ULTRASIGNS.
IT CANNOT BE REPRODUCED,
COPIED OR EXHIBITED, IN WHOLE
OR PART, WITHOUT FIRST
OBTAINING WRITTEN CONSENT
FROM ULTRASIGNS.
Page 1 of 5
TO PRODUCTION
>ecember 21, 2005
CLIENT APPROVAL
SECTION B
REVERSE PAN CHANNEL
WITH LED ILLUMINATION
SIGN TO BE UL APPROVED AND BEAR UL LABEL
TEL: 858-569-1400 FAX: 858-569-1453
9025 BALBOA AVENUE, STE 150
SAN DIEGO, CA 92123-1520
EGENTS BANK
JOB INFORMATION
REGENTS BANK
1921 PALOMAR OAKS WY
CARLSBAD, CA
SALESPERSON
RON BREEN
DESIGNER
DAVID GREEN
SKETCH NO
REGENTS01
DATE
11-03-2005
REVISION DATES
(D11-04-2005 DAG
<2> 11 -30-2005 DAG
<t> 12-05-2005 DAG
CD
VOLTAGE
120 VOLTS
PRIMARY ELECTRICAL
TO SIGN LOCATIONS IS TO BE
PROVIDED BY OTHERS.
A 20 AMP DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS
AND A GROUND RETURNING TO
THE PANEL IS REQUIRED FOR
ALL INSTALLATIONS.
COLORS REPRESENTED
IN THIS DRAWING ARE FOR
PRESENTATION PURPOSES ONLY.
THEY WILL NOT MATCH YOUR
FINISHED PRODUCT PERFECTLY.
COLOR CALLOUTS ARE FOR A
MATCH AS CLOSE AS POSSIBLE.
THIS ORIGINAL DESIGN IS THE
SOLE PROPERTY OF ULTRASIGNS.
IT CANNOT BE REPRODUCED,
COPIED OR EXHIBITED, IN WHOLE
OR PART WITHOUT FIRST
OBTAINING WRITTEN CONSENT
FROM ULTRASIGNS.
PROPOSED ELEVATION SCALE 1/8"=1'-0"
Page 2 of 5
TO PRODUCTION
)ecember 21, 2005
CLIENT APPROVAL
AS-IS ELEVATION
TEL: 858-569-1400 FAX: 858-569-1453
9025 BALBOA AVENUE, STE 150
SAN DIEGO, CA 92123-1520
JOB INFORMATION
REGENTS BANK
1921 PALOMAR OAKS WY
CARLSBAD, CA
SALESPERSON
RON BREEN
DESIGNER
DAVID GREEN
SKETCH NO
REGENTS01
DATE
11-03-2005
REVISION DATES
1 1-04-2005 DAG
-30-2005 DAG
12-05-2005 DAG
VOLTAGE
120 VOLTS
PRIMARY ELECTRICAL
TO SIGN LOCATIONS IS TO BE
PROVIDED BY OTHERS.
A 20 AMP DEDICATED CIRCUFT
WITH NO SHARED NEUTRALS
AND A GROUND RETURNING TO
THE PANEL IS REQUIRED FOR
ALL INSTALLATIONS.REGENTS BANK
COLORS REPRESENTED
IN THIS DRAWING ARE FOR
PRESENTATION PURPOSES ONLY.
THEY WILL NOT MATCH YOUR
FINISHED PRODUCT PERFECTLY
COLOR CALLOUTS ARE FOR A
MATCH AS CLOSE AS POSSIBLE.
THIS ORIGINAL DESIGN IS THE
SOLE PROPERTY OF ULTRASIGNS.
IT CANNOT BE REPRODUCED,
COPIED OR EXHIBITED, IN WHOLE
OR PART, WITHOUT FIRST
OBTAINING WRITTEN CONSENT
FROM ULTRASIGNS.
Page 5 of 5
December 21, 2005
CLIENT APPROVAL
TEL: 858-569-1400 FAX: 858-569-1453
9025 BALBOA AVENUE, STE 150
SAN DIEGO, CA 92123-1520