HomeMy WebLinkAboutPS 06-68; Pick Up Stix; Sign Permits/Programs (PS)MflR-27-2006 13=41 CflRLSON RESTftRUflNTS 972662558B P.03/06
City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
(760)602-4610
PLANNING APPLH
REC'DBY
DATE
SIGN FEE
SIGN PROGRAM FEE
RECEIPT NO. ^>
REVIEW FOR SIGN PERMIT
Planning Department
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property Hne(s) for all proposed freestanding sigrt(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign{s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE.
The application must be submitted prior to 4:00 n.m.
NAME OF PROJECT: T\Cr~ ~~ U *Q\
ADDRESS OF PROJECT: /'^O fTv£
s^
^ni^
Average processing time: 2
T'X?
^ &OcJru3<s
weeks
ASSESSOR PARCEL NUMBER: *• ' ^^ ~~ &&- / ~~?
RELATED PLANNING CASE NUMBER(S):
TYPE OF DEVELOPMENT:
(a) Residential
V\b<«»rv\»«A SC ^) Commercial
(c) Office/Industrial
(d) Hotel/Mote)
(c)
(0(g)
(h)
Service Station
Prof. Care
Theater
Govt/Church
(0(i)
00
(»)
Public Park
Produce Stand
Nursery
P-U/OS Zone
SIGN PROGRAM AND/OR
SPECIFIC PLAN CRITERIA Yes NoD
VILLAGE REDEVELOPMENT AREA YesQ >
SIGN ORDINANCE: Yesjg? No Q
COASTAL ZONE: YesQ ^
Form 10 Revised 12/04
Specific Plan Number
Requires VR Approval
I of 4
MflR-27-2006 13=43 CflRLSON RESTfiRUfiNTS 9726625588 P.06/06
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
TOTAL BUILDING STREET FRONTAGE
TOTAL SIGNAGE ALLOWANCE
EXISTING SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AT PRESENT
PROPOSED SIGNAGE (SQ. FT.)
REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN
K//M
\o'
bb.b'/
sq. 11
sq. ft.
sq. ft.
set. ft.
sq.ft.
OWNER APPLICANT
NAME (PRINT OR TYPE)NAME (PRINT OR TYPE)
MA 1LING ADDRESS
'Zoo £-
MAILING ADDRESS
}1VUt>Dr.
CITY AND STATE ZIP TELEPHONE C3TY AND STATE ZIP TELEPHONE
09
\ CERTIFY THAT i AM TH1! LKGAL OWNER AND THAT
AU. THE ABOVE INFORMATION IS TRUE AND
CORRECT TO TMKffii-ST OF MY KNOWLEDGE.
1 CERTiPY THAT i AM THE REPRESENTATIVE OP "!H1IA-:GAI, OWNER AND THAT AIL n IE ABO vr INFORMA-
TfON IS TRUE AND CO8RRC/' TO TIIG BIJST Ol" MY
KNOWI,eDGE.
->M*t
DATE SIGNA DATE
PLANNER CHECK LIST:
1.
2.
3.
4.
Field check by planner.
Within maximum length, area.
Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
Location: <» In right-of-way
»> In visibility triangle at corner
Pole and monument signs to be checked by Traffic Engineering, for visibility issues
When approved route copy toData Entry
APPROVED: Planners Date:
»»«»»»»«•«««»*
Form 10 Revised 12/04 Page 4 of 4
TOTftL P.06
MflR-27-2006 13:42 CRRLSDN RESTflRUfiNTS 9726625588 P.04/06
EXISTING SIGNS:
NUMBER
Pole
SIGN AREA SIGN HEIGHT
Monument
Wall
Suspended
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes Q No D
PROPOSED PERMANENT SIGNS:
Date
TYl'E
Pole**
Monument**
Wall
Suspended
Directional
Canopy
Freestanding**
(Project
Identity)
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
^"3
MAXIMUM
SIGN
AREA
T6/Z/
PROPOSED
SIGN
AREA
M*.^
MAXIMUM
SIGN
HEIGHT
^-*-
PROPOSED
SIGN
HEIGHT
!_«• "
PROPOSED TEMPORARY SIGNS:
TYPE
Construction**
For Sale**
Banner
MAXIMUM
NUMBER
ALLOWED
NUMBER
PROPOSED
MAXIMUM
SIGN
AREA
PROPOSED
SIGN
AREA
MAXIMUM
SIGN
HEIGHT
PROPOSED
SIGN
HEIGHT
j
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for
potential sight distance and visibility issues. Additional information must supplement this application
showing how the proposed signage will not encroach into the public right-of-way or present a traffic
hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs.
Form 10 Revised 12/04 Page 2 of4
MfiR-27-2006 13:43 CRRLSON RESTflRUflNTS 9726625588 P.05/06
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SI«N
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Traffic Engineering Department, which will not allow signs to be
approved over the counter. Additional time will be required foron-site inspection.
Show building /s
Show all property lines
P/L
^4
] /i .•
>/L J /
i/
curb line
•
r
s
•*
*
Sight Visibility
ii
Sight Distance Requirem
1
I
j
1
how setbacks from all CD
i
i
i
Street Name(s)
1
i
tent
trbs
jj
i
|
i
North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
Form 10 Revised 12/04 Page 3 of4
City of Carlsbad
1635 Faraday Avenue Carlsbad CA 92008
Applicant: LOREN ELECTRIC SIGN
Description
PS060068
Amount
45.00
Receipt Number: R0056471
Transaction Date: 04/03/2006
Transaction ID: R0056471
Pay Type Method Description Amount
Payment Check 22626 45.00
Transaction-Amount: 45.00
MflR-27-2006 13:39 CftRLSON RESTftRUftNTS 972G625588 P.01/06
DONAHUe
SCHRIB€R
March 23, 2006
General Counsel
PICK UP STIX, INC.
c/o Carlson Restaurants Worldwide inc.
4201 Marsh Lane
Carroilton, Texas 75007
RE: Sign Response for Pick-Up Stix
Poinsettia Village
Carlsbad, California
The sign re-submittal received at our office for the above-referenced project has been
reviewed and approved. Please use the comments noted on the drawings and the
guidelines listed below to make the necessary adjustment to your documents.
1. Alt signs shall be reviewed for conformance with the sign criteria and overall
design quality and is not a plan check for dimensional errors, code violations or
any other restrictions to the property. Approval or disapproval of sign submittals
based on aesthetics of design shall remain the sole right of the
Landlord/Manager.
2. Prior to the installation and manufacture of any sign, the Tenant shall provide
Landlord with a copy of the sign permit from the governmental agency having
jurisdiction.
3. Each tenant shall be responsible to repair any damage to any surface caused by
the signage or its' installation.
4. Landlord reserves the right to periodically hire an independent electrical
engineer, at Tenant's sole expense, to inspect the installation of all Tenants'
signs. Tenants shall be required to have any discrepancies and/or code
violations corrected at Tenant's expense. Any code violations, requests for sign
removals, or discrepancies not corrected within fifteen (15) days of notice, may
be corrected by the Landlord at Tenant's expense.
5. Upon vacancy, Tenant shall remove sign and restore fascia to original condition
at Tenant's sole cost and expense within fifteen (15) days of expiration of term or
earlier termination of Tenant's lease.
200 'i. £-<f.'!l '••>•':-:•'.
:'..,hu: I'.''.'
'.o^t-i iMo.j. s.'.A '.')"•:».•: i j
MfiR-27-2006 13=40 CfiRLSON RESTPRUftNTS 972662558B P.02/06
March 23, 2006
Pick-up Stix - Poinsettia Village
Page 2
6. Exposed junction boxes, transformers, lamps, tubing, conduit, raceways or neon
crossovers of any type are NOT PERMITTED.
7. Sign manufacturer's names, stamps, or decals may not be visible from the street
or normal viewing angles.
8. Tenant's sign contractor shall install and connect sign display and primary wiring
at sign location approved by Landlord. Signs are to be connected to the J-box
provided by the Landlord, which is connected to the Landlord's house panel, and
shall be wired to Landlord's control at Landlord's timer for uniform control of
hours of illumination unless otherwise directed by Landlord.
9. Prior to sign installation, we require the following:
a. A copy of your sign contractor's insurance certificate naming "Donahue
Schriber Realty Group. L.P.; Donahue Schriber Realty Group, Inc.: and
Poinsettia Associates", as additional insured (with additional insured
endorsement page attached).
b. A copy of the permit and the contractor's license
Should any other contractor provide installations or other work on the site,
please call the Property Manager, Pat Snow, 858.793.5757 to coordinate
insurance requirements.
10. Submit acrylic cover color samples for approval.
Should you have any questions, please let me know.
Sincerely,
DONAHUE SCHRIBER
Scott Lawrence
Director of RE IT Construction
cc: Pat Snow, DSRG
July 25, 2006 DONAHUG
5CHRIBER
General Counsel
PICK UP STIX, INC.
c/o Carlson Restaurants Worldwide Inc.
4201 Marsh Lane
Carrollton, Texas 75007
RE: Sign Response for Pick-Up Stix
Poinsettia Village
Carlsbad, California
The sign re-submittal received at our office for the above-referenced project has been
reviewed and approved. Please use the comments noted on the drawings and the
guidelines listed below to make the necessary adjustment to your documents.
1. All signs shall be reviewed for conformance with the sign criteria and overall
design quality and is not a plan check for dimensional errors, code violations or
any other restrictions to the property. Approval or disapproval of sign submittals
based on aesthetics of design shall remain the sole right of the
Landlord/Manager.
2. Prior to the installation and manufacture of any sign, the Tenant shall provide
Landlord with a copy of the sign permit from the governmental agency having
jurisdiction.
3. Each tenant shall be responsible to repair any damage to any surface caused by
the signage or its' installation.
4. Landlord reserves the right to periodically hire an independent electrical
engineer, at Tenant's sole expense, to inspect the installation of all Tenants'
signs. Tenants shall be required to have any discrepancies and/or code
violations corrected at Tenant's expense. Any code violations, requests for sign
removals, or discrepancies not corrected within fifteen (15) days of notice, may
be corrected by the Landlord at Tenant's expense.
5. Upon vacancy, Tenant shall remove sign and restore fascia to original condition
at Tenant's sole cost and expense within fifteen (15) days of expiration of term or
earlier termination of Tenant's lease.
200 E. Baker Street
Suite 100
Costa Mesa, CA 92626
(714) 545-1400
FAX: (714) 545-4222
http://www.donahueschriber.com
July 25, 2006
Pick-up Stix - Poinsettia Village
Page 2
6. Exposed junction boxes, transformers, lamps, tubing, conduit, raceways or neon
crossovers of any type are NOT PERMITTED.
7. Sign manufacturer's names, stamps, or decals may not be visible from the street
or normal viewing angles.
8. Tenant's sign contractor shall install and connect sign display and primary wiring
at sign location approved by Landlord. Signs are to be connected to the J-box
provided by the Landlord, which is connected to the Landlord's house panel, and
shall be wired to Landlord's control at Landlord's tinner for uniform control of
hours of illumination unless otherwise directed by Landlord.
9. Prior to sign installation, we require the following:
a. A copy of your sign contractor's insurance certificate naming "Donahue
Schriber Realty Group. L.P.: Donahue Schriber Realty Group. Inc.; and
Poinsettia Associates", as additional insured (with additional insured
endorsement page attached).
b. A copy of the permit and the contractor's license
Should any other contractor provide installations or other work on the site,
please call the Property Manager, Pat Snow, 858.793.5757 to coordinate
insurance requirements.
10. Submit acrylic cover color samples for approval.
Should you have any questions, please let me know.
Sincerely,
DONAHUE SCHRIBER
Scott Lawrence
Director of REIT Construction
cc: Pat Snow, DSRG
SIG> PERMIT No.ps
• .—_
^PROVED BY
37'
PICK UP STIX RESHIZirS"
ASIAflLAVORS
22'-Q"
I I I
NORTHEAST ELEVATION (FRONT)
PUSSL16/5 - ILLUMINATED WALL SIGN (22.2 SQ. FT.)Scale: 1/4" = 1'-0"
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whlttler, CA 90601
Tel: (562) 946-7545
Fax:(562)949-5707
CA. St. Lie.: 455415
DBAWNGfflEVSION NQ:
06-01 -1782R7
RftGENQ:
CLIENT!
PICK-UP STIX
ADCHBSS/STDHE NQ :
7150 AVENIOA ENCINAS
CARLSBAD, CA
CONTACT
DATE:
1/20/2006
SALES HER:
DOUG MALO
DESIGNER:
NICK MORA
REVISION DATE:
03^21/06
REVISION BY:
NICK MORA
ALL IDEAS. PLANS. AMD ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BVLOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OH Dl SCLOSE D TO ANY PERSONS.
FIRM Cfl CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LCflEN ELECTRIC
SIGN CORPORATION.
LEASE LINE BEYOND
32'-0"
16 PICK UP STIX ASIAH
FLAVORS
22'-0"
TTT
Til NORTHWEST ELEVATION (REAR)
J
PUSSL16/5 - ILLUMINATED WALL SIGN (22.2 SQ. FT.)Scale: 1/4" = 1'-0"
[i
IDR34
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whittler, CA90601
Tel: (562) 946-7545
Fax:(562)949-5707
CA. St. Lie.: 455415
DBAWINGmEVISION NQl
06-01-1782R7
PAGENQ:
2 CP 7
CLIENT:
PICK-UP STIX
ADCHESSfSTORE NQ:
7150 AVENIDA ENCINAS
CARLSBAD, CA
CONTACT
fifiJE,
1/20/2006
DOUG MALO
DESIGNER:
NICK MORA
BB/ISICN DATE:
REVSIONBY:
NICK MORA
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BVLOREN
ELECTRIC SIQN CORPORATION AND
SHALL NOT BE REPRODUCED. USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN ELECTRIC
SIGN CORPORATION.
LEASE LINE BEYOND
I I II I I I I I I I I I I I I I I I I I I I I I I I I I I !
NORTHWEST ELEVATION (REAR)
PUSSL16/5 - ILLUMINATED WALL SIGN (22.2 SO. FT.)Scale: 1/4" = 1'-0"
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whlttler, CA 90601
Tel: (562) 946-7545
Fax:(562)949-5707
CA. St. Lie.: 455415
DRAWINGl'HBdSIOM NQ;
06-01-1782R7
PAGENQ:
2^7
CLIENT:
PICK-UP STIX
ADCRESS/STDRE IMQ:
7150AVENIDAENQNAS
CARLSBAD, CA
CONTACT!
DATE:
1/20/2006
DOUG MALO
DESIGNER:
NICK MORA
REVISION DATE:
0^21/06
REMSIONBY:
NICK MORA
ALL IDEAS, PLANS. AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BYLOHEN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR Dl SCLOSE D TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOR EN ELECTRIC
SIGN CORPORATION.
N AS.JUI- A FLAVC
—
SOUTHWEST ELEVATION (REAR)
PUSSL16/5 - ILLUMINATED WALL SIGN (22.2 SO. FT.)Scale: 1/4" = 1'-0"
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whlttler, CA 90601
Tel: (562) 946-7545
Fax: (562)949-5707
CA. St. Lie.: 455415
DRAW Mff REVISION NQ:
06-01 -1782R7
FAGENQ:
3 CF 7
CLIENT;
PICK-UP STIX
7150AVENDAENCINAS
CARLSBAD, CA
CONTACT
1/20/2006
DOUG MALO
DESIGNER:
NICK MORA
REVISION! DATE:
REWSIONBY:
NICK MORA
ALL IDEAS. PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BYLOREN
ELECTRIC SIQN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
3YOR DISCLOSED TO ANY PERSONS,
FIRM OH CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN ELECTRIC
SIGN CORPORATION.
16'
200"
>ICK WP ASIAN
FLAVORS
PUSSL16/5 - ILLUMINATED WALL SIGN
TOTAL: 22.2 SQ. FT.Scale: 3/4" = 1 '-0"
.040 Aluminum
Returns painted Semi-gloss black
'/*" Push Through Acrylic
Digital printed graphic
.QBQAiuminurriBacKs
6500 White Neon
Letter Interior Painted White
Glass Stand
GTO
Electrode Boot
Drain Hole
Wall (varies)
(or other accredited testing laboratory)
ELECTRIC SIGN SECTION
NOTE: GIF TRANSFORMERS
ACCORDANCE WITH 2161
Mechanical Fasteners w/Spacers T.B.D.
Minimum (4) Per Letter
Primary Electrical Source
(1/2'Condiit Minimum, Metal Shown)Ret Nee 600-6 & soo-21
Listed Disconnect Switch In Primary
TO Be Within Sight or Sign (sign
Includes TransforrnerEnclosureJ
Ref: Nee 110-3 (b), 600-2,600-4
3fl3" minimum listed Conduit (metal shown)
& Listed gto cable (secondary side only &
to the next section letter)
110-3 (b) 8600-31
i(y—Listed Sign Section
(consists Of Transformer
And Enclosure) Suitable For
Outdoor Locations Unless
Marked For indoors only
Bonding Jumpers (#WAwg Cu Mln) With Listed Connection
Device Or Fitting Required !f(1) All Flexible Metal Conduit In
Installation U sed As A Ground Return Path Exceeds 6 Ft. (ref
Nee 350-5 Exc. 2), or (2) Channel Letter is Non Metallic, Per.
MEC250^13 (G), 250-113,AMD 600-5
SPACING TABLE
A Between Primary Wiring And insulated High Voltage Wiring
B. Between Insulated High Vclage Wiring And Dead Metal
Where Wring Parallels Dead Metal For More Than 1" WithinSign Sections.
C. Between Neon Tube (if Over 75000 Volt Circuil) And Dead Metal
D. Between Uninsulated High Voltage Conductors Or
Components, (midpoint-grounded Transformer) And
Metal (ground), Low Voltage Circuil Conductors And HighVortagg Conductors Of Opposite Polarity
.040 Aluminum
Returns Painted To Match Red #2793 Aery Ic
r Red Trim cap
AcryBc Face Red #2793 Acrylic
(day/night Clack vinyl
on white acrylic for down stroke of x)
.060 Aluminum Backs
Red IMeon illumination - (6500 White Neon for down stroke or x)
Letter interior Painted wnite
Glass Stand
GTO
Electrode Boot
Drain Hole
Wall (varies)
Mechanical Fasteners w/1 Spacers T.B.D.
Minimum (4) Per Letter
Primary Electrical Source
(1 /2" Conduit Minimum, Metal Shown)
RefNec 600-6 & 600-21
Listed Disconnect Switch In Primary
To Be Wiiftin Sight Of Sign (sign
Includes Transformer Enclosure)
Ref Mec 110-3 (b], 600-2, 600-4
3/8" minimum fisted Conduit (metal shown)
a Listed gto cable (secondary side only &
to the next section letter)
Ref nee 11 0-3 (b}& 600-31
MjLISTH)
(or other accredited testing laboratory)
ELECTRIC SIGN SECTION
NOTE: GIF TRANSFORMERS IN
ACCORDANCE WITH 2161
>— Listed Sign Section
(consists Of Transformer
And Enclosure) suita&fe For
Outdoor Locations Unless
Marked For Indoors Only
:onding Jumpers (#14 AwgCuMin) With Listed Connection
Device Or Fitting Required tf(l)AH Flexible Metal Conduit in
Installation Used As A Ground Return Path Exceeds 6 Ft. (ref
Nee 350-5 Exe. 2), Or (2) Channel Letter is Non Metallic, Ref.
NEC 250-43 (G), 250-113. AN D 600-5
SPACING TABLE
A Between Primary Wiring And Insulated High Voltage Wiring
B. Between Insulated High Voltage Wiring And Dead Metal
Wiere Wiring Parallels Dead Metal For More Tfi an 1" Within
Sign Sections.
C. Between Neon Tube (if Over 75000 Vott Circuit) And Dead Metaf
D. Between Uninsulated High Voltage Conductors Or
Components, (midpoint-grounded Transformer) And
Metal (ground) Low Vhtsge Circuit CcnductorsAnd HighVoltage Conductors Of Opposite Polarity
VOLTAGE
1001 TO 6000
A
'' "^H 1
TON"-
1 1 ""rM |
£
7500V. 1
-s$mr
natioil
3" deep returns painted black
Aluminum face pairted biack
White i.e.d.s
Clear lexan Backs
Letter interior painted white
Flexible conduit
Low voltage power supply
Angleclips pop riveted to iexan oacKs
Drain Hole
Wall (vari es)
O|Lj LISTED
(or other accredited testing laboratory}
ELECTRIC SIGN SECTION
Mechanical Fasteners wf 1-1/2" Spacers
Minimum (4) Per Letter
Primary Electrical source
(1/2" Conduit Minimum, Metal Shown)
Ret: Nee 600-6 & 600-21
Listed Disconnect Switch tn Primary
To Be Within Sight OT Sign (sign
Includes Transformer Enclosure)
Ref: Nee 110-3 (b),600-2. 600-4
3/8" minimum listed Conduit (metal shown)
S IJsted gto cable (secondary side only a
to tne next section letter)
Ref nee 110-3(5) £600-31
ILLUMINATED CHANNEL CABINET DETAILS CHANNEL LETTER DETAILS
Scale: N.T.S.
L.E.D. ILLUMINATED REV. CHANNEL LETTER
Scale: N.T.S.
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whlttter, CA 90601
Tel: (562) 946-7545
Fax:(562)949-5707
CA. St. Lie.: 455415
DRAWING/REVISION NQ:
06-01-1782R7
PAQENQ:
4 cr 7
CLIENT:
PICK-UP STIX
ADmEBSfSTDHENQ:
7150AVENIDAENCINAS
CARLSBAD, CA
CONTACT!
1/20/2006
DOUG MALO
DESIGNS*
NICK MORA
REVISION DATE:
03/21/06
NICK MORA
ALL IDEAS. PLANS. AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BYLOREN
ELECTRIC SIQN CORPORATION AND
SHALL NOT BE REPRODUCED. USED
BY OR Dl SCLOSE D TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN ELECTRIC
SIQN CORPORATION.
SERVICE CORD
• DISCONNECT SWITCH
ALUMINUM CHANNEL
W/ COVER PLATE
.050 RETURNS (BLACK GLOSS PRE-COAT)
EXTERIOR FACE TO BE CLEAR PLEX
W/ RED/YELLOW
AND BLACK VINYL APPLICATION
INTERIOR FACE TO BE OPAQUE WHITE PLEX
W/ RED/YELLOW
AND BLACK VINYL APPLICATION
CLEAR PLEX
%"BLACKT/C«
%"BLACK P.V.C.
.UMINATED INTERIOR SIGN
HEIGHT
VARIES
24"~36"
Scale: 3" = 1 '-0"
LDR34
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
Whlttier, CA 90601
Tel: (562) 946-7545
Fax: <562)949-5707
CA. St. Lie.: 455415
DRAW MO/REVISION NQ:
06-01 -1782R7
CUEMT!
PICK-UP STIX
AOmESS/STORE NO:
7150AVENIDAENCINAS
CARLSBAD, CA
CONTACT-
DATE:
1/20/2006
DOUG MALO
DESIGNER:
NICK MORA
REVISION DATE:
03/21/06
HEM SIGN BY:
NICK MORA
ALL IDEAS. PLANS, AMD ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED E(V LOREN
ELECTRIC SIQN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TOANY PERSONS,
FIRM OR CORPORATION FOR ANYPURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOR EN ELECTRIC
SIGN CORPORATION.
JACK CHAIN
NYLON STRAP
VENTEX TRANSFORMER W/ POWER CORD & ON/OFF SWITCH
15mm YELLOW
13mm CLEAR PUMPED RED
8mm CLEAR
INTERIOR - ILLUMINATED OPEN SIGN
Scale: 3" = 1 '-0
IDR3M
LOREN ELECTRIC
SIGN CORPORATION
12226 Coast Drive
WMttler, CA 90601
Tel: (562) 946-7545
Fax:(562)949-5707
CA. St. Lie.: 455415
DRAW IMG/HEM SION NQ:
06-01-1782R7
FAGENQ:
6 OF 7
CLIENT:
PICK-UP STIX
ADCRB^S/STCfiE NQ:
7150AVENIDAENCINAS
CARLSBAD, CA
CONTACT!
PATE:
1/20/2006
DOUG MALO
DESIGNER:
NICK MORA
REVISION! DATE:
03^21/06
REVISION BY:
NICK MORA
ALL IDEAS PLANS. AND ELECTRONIC
ART INDICATED ON THIS DRAWING ABE
COPYRIGHTED AND OWNED BYLOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS.
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN ELECTRIC
SIGN CORPORATION.
/""\ SITE MAP
Scale: N.T.S.oSIGN LOCATIONS
Scale: N.T.S.
ICRiJ
LOREN ELECTRIC
SIGN CORPORATION
12226 Cpast Drive
Whlttler, CA 90601
Tel: (562) 946-7545
Fax:(562)949-5707
CA. St. Lie.: 455415
DRAWIMQffEVSIQN NO.:
06-01-1782R7
RAGE NO:
7 OF 7
CLIENT.
PICK-UP STIX
ADCRESS/STOHE NQ:
7150AVENIDAENQNAS
CARLSBAD, CA
CONTACT:
1/20/2006
DOUG MALO
DESIGNER:
NICK MORA
REVISION DATE:
03/21/06
REVSPNBY:
NICK MORA
ALL IDEAS. PLANS. AND ELECTRONIC
AHT INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BYLOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR Dl SCLOSED TO ANY PERSONS.
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOHEN ELECTRIC
SIGN CORPORATION,