Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PS 08-05; North County Pontiac GMC; Sign Permits/Programs (PS)
1-5% ·-_____:___:.., 2o/o 11-1Y's 21'is ~-c-~--H- <D ;;:;:::: r.o ' cD s:cinless Steel Cladding. 128428311 (Ship Loose) I I I I I I I I I I I ~Block AnodiLed Aluminum / Face Retailler. 1--------Product Signbox Asser"bly 128426901 1--------Stainless Steel Cladding. ELECTRICAL SUMMATION 14 -F96T12/DSGN 50/110 Lamps 6 F72T12/D::JGN 50/HO Lamps 4 -F36T12/DSGN 50/HO Lamps VA~MONT C:Lt.Cl RIC EOUIPMEN: (SEE JWG. 2845730) 3 Ballast for 12 -96" Lamps © 3.90 Amps. Each -Rollast for 2 72" l_onps & ? 96" lamps © 3.90 Amps. Each -Ballast for 4 -72" Lamps © 3.90 Amps. l:.oc~ -Ballast for 4 -36" Lam;:>s © 1.90 Amps. Each -20 Amp. Circuit: 3x3. 90 Anps. " 11.70 Amps. ~ n ------Division lnsigna and Copy Panel. 1-20 Anp. Circuit: 2 x 3.90 Amps.+ 1.90 At"1ps. = 9.70 Arr;:>s. II I ~ -a Q) .0 E Q) Ul ;{ ' I ~I ~ 0 ~ ' N I> ' I I I +-----cc::-::-::"- 1 I I I 1,......-YI "T I I I I I I I I I I I Hinged for service. --j__W~-----Dealer Name Panel. ..... Hinged for service. Outside Corner Trim I 2/772' Escutc eon Face Left 28,f2B 4 Escutcheon Face Right 128428331 Esculc eon Cladding 284 08 7 II II :: Escutcheo1 Face Center 128428351 -LO I ' I ~ago Support Plate 1840805. II II II II II II II II II II II II II II II Install 1" E.M.T. Conduit---I be"ind cladding for I I II electrical service to 11 I illur'linatcd sign boxes. II l q Logo Signbox 128438301 :3-1 Y'16 Square / Column and Cladd:ng Assembly. 12840770] (See Drawing 2840770 for Assembly Details ) 1.0 II II II II II II I Touch up column ~lange faces and Escutcheon faces. Refer to Llstallation Specs. (Paint s1ipped • Q. ' N1 ' 101/2 " _jjl:_ ..,.._ 'I II: II' II' II II II II II II II II II II II II II II II II II II II II 4-4 8-0 I I 1 10 1/z ---i~li-- j II I I ~ I I I I _f.Lf\ with s1gn.l NEMA 3R Pull Box 128400951 See Crcwing 2845730 or 2845740. Bose Cover Assembly 128{0430] lauch up as required. (Point shbped with sign.) Caulk top joir,ts. Finished Grode ·'--)I ..J.L lj__ I I ~--'-IHI+-1 ---r---·---------r T1-II -II illl I II It other s1gns os required. I --Y IT ll ----TTTT---I II 1r --------c ,a I 1 11 11 1111 11 11 11 /To ' II II II 1111 II II II I _L __ ____ ::-_ _ ~ ~ = = = = = = = = =~ = ~~ ~~ == = == )L = = = = ~~ ~~~ = ~= = = == ==== =r==-= == I II II 11 II II --J--~ I I II II ,j II II Rigid electrical conduit fro·ll building. I c;s=;s=i;.r• co=<S=v' ~I See Elec:rical Installation Specs. and I ~ & Anchor Bolt Deta Is. See Dwg. 2840320. Dwg. 2845810. I I Foundation L _____________________ ~ SIGN PART INSTALLATION NO. 2840050 North County ='ontiac GMC Carlsbad, California. MAG\IETEK ELECTRIC EOUIP1v1ENT (SEE DWG. 2845740) 3 -Ballast for '•2 -96" Lamps © 3.50 Amps. Ecch -Ballas\ for 2 -72" Lamps & 2 -96" Lcr'lPS © 3.50 Amps. Each -Ballast for 4 -72" Lamps © 2. 70 Amps. Eac1 -Ballast for 4 -36" lamps © 2.40 All'ps. Each -20 Amp. Circuit: 3x3.50 Amps.= 10.50 Arrps. 1-20 Amp. Circuit: 3.50 Amps.+ 2.70 Am;:>s. +2.40 Amps.= 8.60 Arrps. USE WITH CRAWINGS 2810770 2840320 28404.30 2845730 2845810 2845740 2840850 INSTALLATION SEQUENCE Column & Cladding Assembly Moster F oundo\ion Details Base Cover Assembly Electrical Drowi1g, Volrront [quiprlent Typical Electrical Installation Electrical Drawing, lv1ognetek Equipr1ent Typical Sections llstollotion manual shall be supplied by the seller (subject :o approval by GM-Dil. 1. Install foundation and anchor bolts for columns and bose cover in accordance with Dwg. 28~0320 incorporating elecricol stub up. 2. Erect Column And Cladding Assy. 2840770 on anchor bolls and temporarily secure by tightening anchor bolt nuts. 3. Level and plumb Column And Cladding Assy., fully tighten anchor bolts one grout under base plates as per Sect. 6/0850. 4. Erect Signbox Assy. 2842690 on columns. Con'1ect ports with 8 -Y4 dio. H. S. bolts 2840055, 2840082 and 2840083. Tor que to proof locd as per specifications. 5. Install stainless steel cladding 2842831 on sig.1box ossy. 6. Touch up black point on colunn flcnges, cross member covers ord signbox as necessary using paint furnished w th sign. 7. Install Logo Support Strut 2843833 and Center Escutcheon Cladding 2840818 to underside of signbox .. 8. Install Logo S:gnbox 2843830. Feed wires through nipple. Connect logo signbox to support strut 2844833 with bo!ts, nuts and lockwashers 2840196, 2840198 and 2840086. 9. Extend electrical service U? the column in EIVT conduit to upper junction ')ox and connect to primary circuit leads from logo sigrbox and product signbox. 10. Test all eleclricol circuits for conti1uity and ground. 11. lns:ol; right & left Escutcheon Faces 2842833, 281,2834. Install Center Escutcheon 2842835. 12. Apply Escu:cheon Cladding 2840817. (2-places.l 13. Assemble Close Cover. See Dwg. 2840430 for details and Section 3/0770 on Dwg. 2840770. 14. Caulk top joint betwee~ bose cover and co'umn and clodd:ng ossemb'y. 15. Touch up bose cover using grey point furnished with sign. Expires Dec 31, 2009 PARTS LIST Mark GM Part No. Quant. GM part Name Remarks 2840770 1 Col. & Col. Clad. Assy. See Dwg. 2840770 2842690 1 Product Signbox Assy. 2842831 1 Stain. Stl. Signbox Clod. Ship with 2842690 2840851 4 Y2" Dio. x 1Y2" Hex. Hd. Bol A307 Galv. f----+-------+---+-''-~ ~-~---------- 284 7133 4 #10 Flat Washer Type 304 S.S. Natural 2840086 12 Y2" Split Lock Washer Type 304 S.S. Natural ~------+--------------+------~~~. 2840984 16 •10xY2" P.Hd. T e F Phill 304 S.S. Natural ~---+---~--- 2840055 8 %" Dia. x 3" Hex. Hd. Bo \ A307 Golv. 2840082 8 %" f-'ex. Nut A307 Galv. 2840083 8 %" Flat Washer, Hard A307 Galv. 2843830 1 Logo Sigrbox Assenbly 2840817 (2) Escutcheon Clad. Outer . Shipped with 2840770 2842833 2 Right Escutcheon Face 2840430 1 Bose Cover Assemb y See Dwg. 2840430 2840806 4 Anchor Bolt Assembly See Dwg. 2840320 2842834 2 Left Escutcheon Face 1-----+-------+---+---------+-----------~--------~---~ 2842835 2 Certer Escutcheon Face 1--------+---------l-------~~------------------r----------------Tffi~-i 2840461 6 1i2''Dio.x8" Sq.Hd.Moch.Bolt See Dwg. 2840430 2840462 12 112'' S l~ut See Dwg. 2840430 28404 77 12 See Dwg. 2840430 2840805 art Plate 2843062 24 •10xY'2" Pon.Hd.Moch.Screw 304SS Black ---· ---------- 2843063 24 •10 Split Lock Washer 304SS Natural 2813064 24 •10 Hex. Nut 304SS Natural ' ..f 2840985 12 •10 Flat Wash. Neoprene Type 304SS Natural ----+--------------+--------r~------~----~----r-----~---------------l 18-60CI"-0016 Y2" Dia. x 1Ya" Nipple r----~--+-- 2843061 Yz" Flex Steel Conduit 2-0 Long 2810032 2 Y2" x 90' Flex Connector Appleton *7381V 18-200-0010 2 Outlet Box Raintite L -14 18-300-0004 1" Flex Roinlite Conduit 3· 0 Long r------+------+-------+~----------------~----~------------~ 18-340-0015 1 Yz" Flex Raintite Connect Straight 18-340-003' 2 1" Str. Flex Coll'pression 18-425-0050 2 Outlet Box Gang Blank 2840196 8 2840198 8 2840095 1 Touch Up Point, Block G.I~.D.I. Spec. •2-5o4 Touch Up Point, Grey G.I~.D.I. Spec. •2-5o4 Yz"Dio.x1%"Hex.Hd. M.Bolt Y2" Hex. Nut ----------+----~------~~~ NMEA 3R Pull Box [------+---~-___ l ____ _ 2840146 3 1" T. W. Conduit Coupling Appleton •93T -100 284014 7 28-0 1" I:..M.T. l hnwall CondJit 18-550-0002 4 " Locknut, Golv. 2840149 4 1" E.M.T. Clomp Appleton •TWCL-100M 18-600-0038 2 %" Dio. x 1Y2" Ni le Toggle Switch 1------f----- 18-750-0060 1 30 . 2 Pole CORPORATE IDENTITY General Motors NORTH COUNTY PONTIAC GMC CARLSBAD, CALIFORNIA of Revls'on Supersede::! No. ECR No, Dn, Ch. Ap. ECN No. Corporate Identity Dept., General Motors Corp., 3044 'Nest Gro1d Blvd., Detroit Mich. 48202 Unless ot11erwise spocifloC, oil diJOOn~ions ± .010" or 1'32"• all angles± lj' 1J1 Dcte Drown DRS Dote Des:gn l-~by~--------------.o~_-~/,08/ _0~~8 _____ A~p~pr_ov_o_l ------------------------~ Checked by HWS Date Depart100nt Approva I ERN lh Date Project Work Order No. 074636 Sign Model l~o. P137 CRAWl NG T1 TLE INSTALLATION DETAILS 36-0 MOUNTING HEIGHT 90 lv1PI1 WINO GUST per 2001 C.B.C. Date Latest Revision Dote Code DRAWING NUMBER 28~27"5 R f, ~ e n I 2840082 28LJ0083 2BLJ0055 I I I I I I I I LLU 0 '-~ ~28LJ0799 R ' "' ef. ... 2840981 Ref 2840982 Ref 2840983 Ref I 2 3 1/2 2 n SECTION ~ SCALE:3"=1'-0" 2840', 95 28~0198 1_(3_ 400 85 J [_ See Sections 1 & 2 0 r1 J wg. 2 8 4.) 8 50 . :28408051 28<:0195 28'i0198 28'10085 2840851 28LJ0198 28LJ0085 ::: "' N "' "' r-- N Ref Ref Ref <1) -' ~ I n 0 0 I II 0 . /2 I 0 • N.P.T. Ref. 0 0 SECTION A SCALE:3"=1'-0" 18-340-0015 18-200-0010 18-340-0031 "' I I _S_E_C_T_I_O_N_ A 3-5 , ____________ _,~ 2847130 I2B4LJ026f-j ==-~========~~~g.; __ ~.~ L------------------------------------------~ --- 2840832 Ref. 28-'10831 Ref. SECTION A FULL SCALE 284083~ SECTION ~ FULL SCALE #10 Stainless Steel Pan Head Screw with Washer. 2840984 ond 2840985 Ref. SCALE:3"=1 '-O" _c IJ) 0 3= ~ N ' +- =:1 0 L (') ' N I 'rr, / _" j--------1--------'--------1, ~ I lr:r \ N 0 ~ I N / ~-Dry pock co I umn bose ond seat 18-300-0004 COUIP I i rlQ 28410145 Anchor Bolts Ref. 2840806 ~ angles with 1:2 cement-sand I I II I II I II I II I II I I II 111 Ill Ill 1~'111 Ill I ,1-] Ill ~ Ill I Ill ~ N ' II 11:1 I Ill lu_ l!i _ _ _ _!il --'- 1 I' I I I II I I I I I I _D_E_T_A_I_L_@ FUU .. SCA_ E I grout or premixed non shrink grout. Condui-t 2840147 I I:! '-16rJ SECTION A SC/\LE:1"=1'-0" 2842833 Ref.--_,~1 2843087 Ref.-- 7 SECTION A SCALE:3"=1'-o" 2840811 Ref. Clomp. Screw & Washer. 28401LJ9 2840984 2847133 NORTij COUNTY PO'JT I AC GMC CARLSBAD. CALIFORNIA Expires Dec 31, 2009 118 550 CORPORATE IDENTITY Gan~ral Motors 18-500-0038 18-200-0010 18-750-0060 18-425-0050 I II 0 /2X90 Flex. Connector 2840032 ---1/{x2·-0 Flex Steel Conduit 12843061] 18-600-0016 #1 6 ( . 1 77" D i o. ) hoI e for 28LJ098LJ Screw as required. DETAIL ~8~~ SCALE:3"=1 '-0" om:t Logo Si~n~ox Rotator Descript:on of Revision ECR No. Dn. Ch. Ap. ECN No. No. Superseded No. Corporate cden-tity Dept., General ~otors Corp., 3044 West Grand Blvd., Jetroit '1ich. 48202 , Checked by Unless othe-wise specif.ed~ all dimensions± .010'' or DRS clWS Date 011 o 8108 Design J u Approval Deportment Approval Dote Dote Dote ~~~~~~-~0~7~46~3~6~--~SI~gn~M~od~ei~N=o· __ ~P1.37 -------------~ INSTALLATION SECTIONS TYPICAL ALL HEIGHTS 90 MPH VviND GUST per 2001 C.B.C latest Revisi::m Date Code DRAW! NG NUMBER 2840850 California . c: Finished Grode [J~:: Bose Cover 11~J-#5x9'-5"@ 12" o.c. Top & Bottom I 11 ) -#5 X 1 2 I -5 " @ 1 2 " 0. c . Top & Bo+tom ------------------------------------------------------------" " II 0 I 0 II .c +-u N ' -r-- 1 ,- .,._______ __ _ ---- II II " ,, ' Lerogth = 13-0 ELEVATION • • • • • Wo sh L i ne -e---r----r__,~ • • • • • 1-8 1/4 1-8'/4 -_,... Length = 13-0 <.0 I Electrical Conduit See Anchor Bolt Setting 'leta i I . Electrical Conduit PLAN VIEW SPREAD FOUNDATION Q) ::J .c u ,_ (]) 0. .c Q) 0 0 Vl 0 I L() 0 I L() Q) Q) Vl 0 ::J 1J w .c +-u 0 ::J 1J w Model i"u'Tlber : P137 IQ Height -3 Secord Wind Gust MASTER SPREAD FOUNDATION GLOCK FOUNDATION . c: 2 II II " Bose Cover Fir. Grode r--~ -~~ I • i•! • • • " II \\ ----::,._:::fr::=-:==':: Electrical Conduit ~·-~·---': --· (15) '*6 X 11' 6" (Q 10'' O.C. ?£ •Top & 0Bo\\o~ eoch~w_a_y~·~~·- ·--' N ' lD I r--- ,._. I Length See Schedule ELEVATION • • See Anchor Bolt Setting Detoi 1. I ~--+-----+-~,~!~1· 1. Was I • L i :~e -+---..1--+-~ Electr-ical Conduit Equa I 3-4 1/2 Equa I r---~~--.., I_ Length PLAN VIEW BLOCK FOUNDATION FOUNDATION SCHEDULE VERTICAL SLAB FOUNDATION • 2-#5 Mk.SOO . c: 2 Fin. Grode ~~----------------~---~ " I CD II .c +-u 3 4--~--~·-.. -H~Iul~~h· I' I, Q) ::J .C D +-Q) 0. .c 0 Q) Vl 0 N ' LO I r-- Q) Q) l/) cniC I 1·-~ 2 t • • • • • " II \\ ,, • ------------- -------------· • • • • Electrical Conduit ~---~~--ff5 Vertical • See Scr1edu I e • • l.J..---?,.----ff5 H o 1 i z on t a I See Schedule • • • 3 11 Clr. 3 11 Clr. r-- 1 C'-I I • • • Length ~ 2-6 ELEVATION • • I I I I See Anchor-Bolt Setting Deta i I . 1 1 E I ect1 i co I Conduit ~~-~~~========~~===== I 1: ... 1 o---+---t-:'--1-'II ash L i n e I '.-t--'. I • 1 • • I I I I 5 1/4 Length 5 1/4 2-6 PLAN VIEW VERTICAL SLAB FOUNDATION CAISSON FOUNDATIOI~ ~-#5@11"T&B Mk.SOO 'II II ·~ 0 L o_ Wash 9 3 II /~ Wash Fir. Grode +-::J 0 L '-" Q) ::J .C D +-Q) 0. .c Q) 0 0 Vl • I I • c:+--l~·rffi·d:f:,3·ff~J_~-;_;_LJ_ T----- :2 ':::.- CD u . 0. , )--, rn f- Electrical Co'!duit 1//' D i a. x 8 11 Machine Bolt Wiih double nuis. 16 reqd. J -------- 2840451 /840462 28404 n 1 I " /4 ~~ ~----------~ Q) 3jj Q) -::-:---1---11--t-3" Anchor-Bolt I 284oao5l Assemb I y ___/ E L EVA T I 0 N N ' lD I r-- l/) Clr. Clr. r-- 1 ~ ' r-- 1 1 .. Diameter .. I 3-0 ELEVATION r-- 1 I --r---- ' 1 9 I -----r N ' _::. I N --1--------t See Anchor-Bolt Sett i no De to i I • j__ __ • I ---- '\ \ \ / I Electr-ical Conduit 1 f-+-4...,'\-+--Wash L i ne I , '.--+---.. \ ~ \ . . \ i'-+-__j ""'----I ~ --:-I \ J I 2 1/4 D iometer-2 1/4 --let--------t-- 3-0 PLAN VIEW ' I ' -+---- PLAN VIEW ' . ---{])--------$- N ' - N f:---c-J-.-___ Bose PI ate 1 1 /~x17x18 t----+---+t----+-1--Wash Line ' _____ .___ ~-;ymm. about L \,------'-----'- OF CONCRETE SILL ANCHOR BOLT SETTING DETAILS FOUNDATION NOl E_S: 1. All concrete shall be 2500 psi compressive slrenglh at 28 days. 2. Reinforcing steel shall corform to ASTM A615, grade 60. 3. Foundations are designed for a 11oximum soil bearing pressure of 1000 psf . Factor of safety against overturning is 1.5 for 90 psi wind velocity. 4. Concrete foundation depth for Horizontal Slab must conform to local codes. Adjust depth of footing to correct depth and lengthen sill reinforcing as required. COI~STR'JCTION SEQUENCE: CAISSON FOUNDATION 1. Excavate footirg to dimensions shown on schedule for type and model number selected on sJrvey. 2. Tie, place and support reinforcing mats as shown on drawing. J. r orm silllo dimer,s:ons shown tor casting monolithic with footing. Full size sill template to be furnished by sign manufacturer to hsure fit of base cover. 4. Set anchor bolts to elevation shown and in correct position using template furnished by sign manufacturer. Template mcy be removed after sill is formed and anchor bolts are secured. Model Number Length Width Depth Cu. Yd. nc. Cu. Yd. Length Deplh Wid:h 5. Install electrical conduit at correct depth and stub up beneath base cover at location shown. role in template locates electrical condui:. Reinf. Lbs. Caisso.1 Diorrdcr Width Depth Length Dep':.h P!37@35-90 13-0 1 0-0 3-9 1 8 . 1 12-0 12-D 7-3 38.7 2-6 8-4 10-6 9 116@12 MK511 2-1 D1/2 1.. "I 12#5@11" ~K502 ~[I III 9-#6 MK402 Length = 6-01/2 562.8 8.5 lvsoo 7-10 MK502 10-6 MK 511 2 3-0 13-6 8 #7 .~K702 ; 0-#3 MK301 ~COl MK301 L eng I r. = 8-7 1/4 619.0 7.8 7-01/2 lvSOO "'"'-:---c-:--c---~ ... 2-10 1/2 MK515 13-6 fiK 702 Expires Dec 31, 2009 6_ Cast concrete cgainst cut bank consolidating into place by rodding. 7. Allowable lateral pressure musl not be less than 150 psf/ft of depth. B. All construction must conform to General Motors Corp. contract specs. CORPORATE IDENTITY teneral Motors ~--~------------~--~~~~~ Date Description of Revision No. ECR No. Dn. Ch. Ap. ECN .~o. No. C:x-porate Identity Dept., Genera I Motors Corp .. 3044 West Grand B I vd. , Detroit Mich. 48202 Unless otherwise specified, all dimensions± .010H or 1,3{. oil O'iQies± (j' 151 Drown >j DRS Cl1ecked H W S by ~ark Jrder No. Date Date 074-636 Design Deportment Approva I Dote Sign Madel No. P137 MASTER FOUNDATION DETAILS Date Dote Lates-t Revision Date RTH COUNTY PONTIAC GlviC CARLSBAD, CALIFORNIA DRAWING NUMBER 90 MPH WIND VELOCITY per 2001 C.B.C. 1 Cooe . 2841078 & . 2841079 ce Only. g. *2840770 Pert No Port No Referen See Dw for QJo ntities. a. Holes-~ Wz 'I II II II II II II II II II II II II II II 1'. II II II 1: II 1', II I' II II II II II :I II II II II II II II II II II II II il II II II II II II II II II II II II II II II II II I'\ II ft ff ! Ill 'JL' Typ. All Figs. 1'!6 "" / '/z I"" 45" -~- 1'16V N ~·-1-Piote ""'--"';-, 10 x 1x 10 1213:± 0 7 9 7] --_] . ----+ -~ 10 :.{~--'*- 1 , ' I . --:..=_IT'-T'l I I ' 2 ! 6 '2- oC ~~ ~ +c-~ = ~-~- "' O'l II I S:l · ---------b-~----urr----------- I ~ ~----------~-~ ,.'-Wz ! ! ! -! I I ' I I ' ' I I ' n ' I I ' ' ! _! r-(30)~6Dia. Holes I I/ 0 ' ~ --~ --- 0 ' :£ " U1 "' <D ' ~ N -~-------- 0 ' ~ i/ -f-+-----·-- ' ' -r--r· ' ' I I I I ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I ' ' ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I i i I I ' I I ' ' I I ' I ' rn Ol. ~I 00 N ~ "' -:::::: ~ --; N ~ ' " 00 ~ X Ol ~ X 0 I I I --~---1f:rF:ip:j, 0 ' ~ ' ' I I ' ' I I ' ' I I ' ' I I ' ' I I Typ. Sti"f. 1'/zDia. Hole '----1/zx 1/zCip Corner C .. C' ---1 I ' ' t:t +-+ ,-1' ' ' Surface to be Flat & Square w·t'1 Axis of Column within ~2 (4)~ o· H les 16 10. 0 -· 1-Piale 7x1/4x7'/z 12840801 See Note ''A'' 2840 866 Ref. (2)1 Dia. Holes 2840866 Ref. G ->. ,..... "'t;' ;::::::: --~ --- (8)';116Dio. Holes_y Part No. 2840866 Reference Ooly Fabricator's lden':. Stamp, Both Sides of Web, Under Conduit Hole [fTAIVf:45=9 5] (Week ~--1 -Plate %x3%x8 128410051 1-6 1-Plate 17x11/4x1-6128407941 2 1-2 2 '--~+ ___ _,_ lf) ,.'-1 .n lD ' .. ---·-. -·-----·- ->. o/lo N COLUMN WELDMENT NO. 2840791 Finish Note: Remove Sca'e from Completed Welcment, Sandblast Indicated Faces See Point ecification •2-2. Finished Face and Edges of Flange 1 7 1 5 1 ' ' ""· I I ' 12Yzi I N ' ;;;::'.: I~ I ;;;: I ~ ' m\1 i·~ ot =o=o <D ·m· N I I ' 'T -·-- ~·'I' ~-:t --f--- I N f-·-~ l-N 7 1-6 13;16 1-+---...,·4-----.. ·- 1-P'ate r---l2841008l See Note -+--------------------~--------·------------r------ ->.I ·-·-' ~ See Note "A" -%Dia. Holes 1-C3 x 4.1 x 4-3Ys 2840797 Surface to be Flat & Square w/ Axis of Col. within 1/16. CROSS MEMBER WELDMENT NO. 2840796 Finish No:e: Remove Scale and See Paint Specification •2-2. 4 3%(+~z) : • I • 4YzDia. Hole II I ! i 3fsTyp .. !i ct ;;;v ;;;: - ·-·-·-.. ~:-_::-_ _cc-_~=-- I ! ' I ! • I !,.4 1/4•1 ,;+1/4.,! ·~~ (8l';II~Dia. Holes "------2840804 Ref. 2Yz 2 ' ' I 2 1/z 1 1 71 [ i ~518 1 6 5/~ \ Y8 ' I 10 - 7 ~~~~ ~/~EB~•r,~I,.~~/~E~.,JI~ ~~~M· ~ -.. i ... -1-31-' :;:;~,6~ _ __,'. ___ 1_-_3_13~/1=6--~-.. --_10 __ ... 1 / [2:)28fi24[QOB]80~3}-I ~/ 1_-t+i.l -~j!j 28~047~ ~,,-c-+ ~~--< T y p. /8 LOGO SUPPORT ASSEMBLY PART NO. 2840799 Finish Note: Completed Part to Part No. 2843068 be Hot Dip Golvan:zed After F abricotion and Before Assembly of & 2840474. See Paint Spec. •2-3. 2840802 Ref. 2 I 2 2 8 4 3 0 6 8 Ref.-""Y,"'4~+~•'/~4i~-1/4 1.Ji_ r-cy-:-8-,-< T Y P · 2 i ! T1 ~ ~ I i I ~ 4 %' --- 1 1 ' I I ' I .---T N ~--· ' / I~ ~ %.U1'A ---- I -C"'--Y!sD:a Hole 2-J --+---- 4YzDio. Hole 2840803 Ref. Fabricated Part No. + c 0 " 0 BILL OF MATERIAL Port l<cme Material Spec. Material Description 28L0791 --1-Co I umr1 We I dment Spec. #8-3, #2-2 2840792 281:0793 f---t- 2840794 2841005 2840866 Strop 0 284.3068 10 T i nnerman Nut 2840474 4 2840805 1 Logo Support PI at ss #5-3 A-36 Fob. Part Size or Dimension f---j-------r-··-1--··--· -----+----+----------1-------j 2840806 2840795 ' 2840807 3 Anchor Bo It 2840508 A-325 2840809 ASA 627.2 Caiv. 2840796 2840797 1 Si rut A-36 2841008 2 End PI ate A-36 - 1 ... 7 ' ' I I ' ' I I I I ' ' ' I I I ---• U BRACKET PART NO. 2840804 NORTH COuNTY PONTIAC CiviC CARLSBAD, CALIFORNiA ' ' ' I I I ' ' ' ;;;: I I I 1/s & Year) -----(2l%zDia. Holes SECTION A SECTION& 1 Finished Face and Edges of Flange SECTION~ Expired Deo 31, ~~009 Ys . 4 1/4 4 1/4 Ys ~~~~~·~-n~ I~ (4lo/sDia Holes _______ rr_~_c.~_t_~-~.~- 1 i i i I LOGO PART i---t--t-1 I i-·i+ i--t- ' ________ _._ I I SUPPORT PLATE NO. 2840805 Finish Note: Completed Port to be Hot Dip Galvanized After Fabrication. See Point Spec. ~2-3. "II" 1'!4_Di=-c. --12§±QJ~ /' 284080:8 284080'9 ~ N u z ]'-.. n ' n ' ~ u L f- 1o/16Dio. Hole ©(];,of !I: (3 req'd.l 128407951 Tack nut \o 1!: md Rod to nut. ANCHOR BOLT ASSEMBLY PART NO. 2840806 I ' I I ' I ' ' I % !lY~) , I 1 % Drill (2)•18(0.169) Undersized Ho'es for •10 Self Topping Screws ' ' I ' I I . Wz ~ 1%_! .. sYz ' -'l. -;+----·-···-.-! ' I"'· . ' I I ~sDia. H oles(2l ~ % ~ Ws ;;;: 1-·--·-· ->. ~ ;;;: STRAP PART NO. 2840866 Finish Note: See Paint Specification •2.4. CORPORATE IDENTITY Gen~ral Motors Sigrbox Rotator E:R No. Dn. Ch. Ap. No. No. 'Corporate Identity Dept .• General Motors Corp., 3044 West Grand Blvd .. Detroit Mich. 48202 Un1ess otherwise s;:.eci-'ied. all dimensions± .010" or 1'32", all angles± (1' 151 Dro~~ DRS Date Che~:ed HWS Dole Design Approval Cepor-lment Approva 1 Wort~.. 0:-der No. 4636 COLUMN F /\BRICATED PART DETAILS 36-0 VTG. HT. 90 VPH WIND GUST per 2001 C.B.C. Date ~atest Revision Date Code DRAWING NUMBER