Loading...
HomeMy WebLinkAboutPS 09-06; Capstone Advisors; Sign Permits/Programs (PS)City ofCarlsbad 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-4610 PLANNING REC'D BY _ DATE PLICATION # SIGN FEE ^^fe? - SIGN PROGRAM FEE RECEIPT NO. REVIEW FOR SIGN PERMIT Planning Department AU plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4;00 p.m. Average processing time: 2 weeks NAME OF PROJECT: CQ/?S\CK .;^Jniar5 ADDRESS OF PROJECT: ASSESSOR PARCEL NUMBER: RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential (b) Commercial (c) Office/Industrial (d) Hotel/Motel SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA (e) (f) (g) (h) Service Station Prof. Care Theater Govt/Church (i) Public Park (j) Produce Stand (k) Nursery (1) P-U/OSZone YesD VILLAGE REDEVELOPMENT AREA YesQ SIGN ORDINANCE: YesD COASTAL ZONE: YesQ No • No • No • No • Specific Plan Number . Requires VR Approval • • • • • *********** * * * * * Form 10 Revised 3/08 ****** Page I of 4 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument WaU Suspended Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes • No • Date PROPOSED PERMANENT SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Pole** 1 1 Monument** 1 w WaU I I Suspended Directional Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Construction** For Sale** Banner **Prior to approval, aU proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibUity issues. Additional information must supplement this appUcation showing how the proposed signage wiU not encroach into the public right-of-way or present a traffic hazard. Page 3 of 4 iUustrates an example for what would be required for such proposed signs. *************************************** Form 10 Revised 3/08 Page 2 of 4 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Traffic Engineering Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. Show building/s P/L Show all property lines P/L I , Sight Distance Requirement Show setbacks from all curbs curb line Sight Visibility Street Name(s) 0 North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. Form 10 Revised 3/08 Page 3 of 4 EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) MAILING ADDRESS MAILING ADDRIESS CITY AND STATE ZIP' TELEPHONE CITY AND STATE ZIP TELEPHONE 5, D. cJ\ nm I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THAT I AM THE REPRESENTATfVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMA- TION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE SICjf^ATtJgE-^ ^'•^ DATfe PLANNER CHECK LIST 1. 2. 3. 4. Field check by planner. Within maximum length, area. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. Location: *t* In right-of-way •J* In visibility triangle at comer Pole and monument signs to be checked by Traffic Engineering, for visibility issues. When approved route copy to Data Entry /^lUA- ^Ul^ Date: ^I^I^M 5. 6. APPROVED: Planner: • •••••••••••••••••••••••••••••••••••••• Form 10 Revised 3/08 Page 4 of 4 Carlsbad /\rchitectural Research Center Review Committee 7 October 2008 Mr. Mark Hayden Capstone Advisors 1545 Faraday Avenue Carisbad, Califomia 92008 Re: Lot 104 Capstone Advisors Sign Review Dear Mark: The Architectural Review Committee (ARC) of the Carlsbad Research Center (CRC) has reviewed the sign plans proposed for Capstone Advisors, located at J545 Faraday Avenue. The proposed plans for a smgle wall monument sign and two small tenant identification signs are consistent with the CRC Design Guidelines and therefore the submitted plans are considered APPROVED. Sign construction may begin once a Si^ Pennit is obtamed from the City of Carlsbad and a copy of that permit is forwarded to the CRC. The ARC understands that you would like to use external lighting on the monument. Such lighting is not allowed under the current Design Guidelines, however that aspect of the DGs is currently being considered for revision. The ARC understands that you would like to install the in-ground infrastructure and utilities at the time of sign construction. Please provide plans for the external lighting. The ARC approves the installation ofthe in-ground components with two conditions: the sign may not be illuminated until the DGs are changed and the in-ground infrastructure cannot interfere with mowing of the turf. Note that in the event the DGs are not modified the sign may not be externally lit. Please feel free to call me if you have any questions or require additional information. Sincerely, Seth Schulberg cc: A. Blackmore, C. Blackmore, T. Hageman, W. Beckman and A. Ferris 1S30 Faraday Avenue Suite 100 • Carlsbad, CA 92008 • (760) 931-0780 • (760) 931-S744 Fax CARLSBAD RESEARCH CENTER - ARCHITECTURAL REVIEW COMMITTEE Sign Evaluation Matrix fon Capstone Advisors Monument Sign (10/7/2008) Applicant Address; 1545 Faraday Avenue Building Area: NA Lot No; 104 Sign Criteria CRC Design Guidelines Proposed Dimensions Number per lot Building area < 35,000 ff = 1 wall or 1 monument Building area 35,000 - 60,000 ft^ = 2 wall or 1 monument Building area > 60,000 ft^ = 3 wall 1 monument Number per elevation Monument Sign: 1 per lot. Wall Sign: Building area <35,000 ft^ = 1 Building area > 60,000 f^= 2 1 monument Sign dimensions Not specified 6ft.X3ft=1Sft' 3 ft. X 1.5 fi.=A.5te 0.6 ft X 1.5 ft =1.0 ft^ Area 50.0 ft^ maximum (monument or wall) Total Area= 23.5 ft'' Sign Height Monument sign; > 3 feet, sign must observe building setback of 30 ft. s 3 feet, at least 20 feet from curb Wall Sign; Below eave line 3 ft. Sign Depth Monument signs must be at least 8 inches in depth No standard for wail signs 1 ft. Size of lettering/logo Monument Sign: 18 inches maximum Monument Sign: Address lettering s 7inches (Helvetica) Wall Sign: 24 inches maximum if building area is < 35,000 fl^ 36 inches maximum if building area is > 35,000 ft^ 10 inches 6.75 inches Area of Lettering & logo Capstone ~ 3.3 fl* Advisors = 1.2 ft' WMG --= 0.75 Address = 0.17 ft^ Total Area = 5.4 ft^ Percent coverage of lettering and logo Logo/logtype area may not exceed 1/3 of total sign area. No standard for wall signs 23% Lighting Must be internally lit No Lighting^ Location Monument sign: Near Bie primary access point to the lot. Wall sign: May not be mounted on any architectural projection, parapet, equipment enclosure or on glass portions of building elevations 20 ft. The CRC Design Guidelines allow one wall or monument sign for buildings with an area of under 35,000 square feet. 1. applicant would like to install in-ground utilities to support extemaHighUng in the event the DGs are modified to allow externa! lighting. Items in bold face are not In conformance with the Design Guidelines of ttw ORG. CARLSBAD RESEARCH CENTER - ARCHITECTURAL REVIEW COMMITTEE Sign Evaluation Matrix for: Capstone Advisors Tenant Identification Signs (10/7/2008) Applicant Address; 1545 Faraday Avenue Building Area: NA Lot No: 104 Sign Criteria CRC Design Guidelines Proposed Dimensions Number per lot Building area < 35,000 ft^ = 1 wall or 1 monument Building area 35,000 - 60,000 ft^ = 2 wall or 1 monument Building area > 60,000 ft^ = 3 wall Number per elevation Monument Sign: 1 per lot. Wall Sign: Building area <35,000 ft^ = 1 Building area > 60,000 ft^ = 2 2 Suite I D. Sign dimensions Multi-tenant buildings are allowed Suite I.D. signs no greater than eft' in area with a maximum text height of 6 inches and maximum logo height of 9 inches. 2 ft. X 3 ft. Area 50.0 ft^ maximum (monument or wall) Total Area= 6.0 fi' Sign Height Monument sign: > 3 feet, sign must observe building setback of 30 ft. £ 3 feet, at least 20 feet from curb Wall Sign: Below eave line NA. Sign Depth Monument signs must be at least 8 inches in depth No standard for wall signs NA Size of lettering/logo Multi- Tenant I.D. Sign: Text 6 inches max. Logo 9 inches max. Monument Sign: 18 inches maximum Monument Sign: Address lettering s /inches (Helvetica) Wall Sign: 24 inches maximum if building area is < 35,000 ft^ 36 inches maximum if building area is > 35,000 ft^ 6 inches Area of Lettering & logo NA Percent coverage of lettering and logo Logo/logtype area may not exceed 1/3 of total sign area. No standard for wall signs Lighting Must be internally lit No Lighting Location Multi-Tenant I.D. signs to be located over or adjacent to the office entrance. Adjacent to doors The CRC Design Guidelines allow one wall or monument sign for buildings with an area of under 35,000 square feet. Items in bold face are not in conformance witti the Design Guidelines of the CRC. 4^ CAPSTONE ADVISOR.S LANDLORD AUTHORIZATION TO PERFORM SERVICES AND WORK Date: December 11,2008 Landlord: Capslono Advisors Inc. 1545 Faraday Avonue Carisbad. CA9200B Re: Signage for Canslone Advisors. 1545 Faraday Avenue. Carisbad CA 92D08 To Whom It May Concern: Mark Hayden, Capstone Advisors Inc. hereby grants permission to ULTRASIGNS ELECTRICAL ADVERTISING, INC. or agent to acquire sign permits, manufocture and install signage for Capstono Advisors Inc.. 1545 Faraday Avenuo. Carlsbad CA 92008 Please contact me at ITMI B04-e90o Ext. 12s If ypu should have any questions or need assistance or contact Joey ^iano at UJ^r^lgns, Permit Department (858) 569-1400 Ext. 110. Sincerely, g .14 > i'AH A IIA V AVI •! ur CAm.siiAn CA 'loon T (7«ii)iiii4 <i«i>u p (7>o) aoj i>90 i 1 City of Carlsbad Faraday Center Faraday Cashiering 001 0901501-1 01/15/2009 75 Thu, Jan 15, 2009 03:25 PM Receipt Ref Nbr: R0901501-1/0042 PERMITS - PERMITS Tran Ref Nbr; 090150101 0042 0048 Trans/Rcpt#; R0073284 SET #: PS090006 Amount: 1 i $56.00 Item Subtotal: $56.00 Item Total: $56.00 1 ITEM(S) TOTAL: $56.00 Check (Chk# 3351) $56.00 Total Received; $56.00 Have a nice day! :t:*+*t*+**:)::f:;*:^;*CLJS I OMER COPY************* City of Carlsbad 163 5 Faraday Avenue Carlsbad CA 92008 III Applicant: ALIANO JOEY Description PS090006 1545 FARADAY AV CBAD Amount 56 . 00 Receipt Number: R0073284 Transaction Date: 01/15/2009 Transaction ID: R0073284 Pay Type Method Description . Amount Payment Check 56.00 Transaction Amount: 56.00 I 10 SISllAIL NOSCAU JOB IIIFOIIMATION CVSTOIEUnSORS 1545nUUIMT CAIIISB«D,C« SALESPIRSO* JOHN HUAYA DUIDHER {(.fiERMAR »nCH HO CAPn002 DATE 1IMII-200a REVISIDH MTEI O) 1146-2008 RLS W n'20.^ainu ^ 12-05-2000 nu nam VERIFY '3 i£3l IKAltlC S tf) t* RfOLKD TO* fal MTfcUUSC It r-a KM£ MS KU t>f t KtL KIT MA;SI ran frees 13 era «pcari nmnn or arnuuNi n UMCt nen?. HKMcif DtMT. UTAM.a vwrnw ccuur TK ten a hnwiEi! TO K Pago 1 of 4 CLIENT APPROVAL TEU85fl-SSB-1400 FAX; 898-569-1493 902S BAIBOA AVENUE. STE 150 SAN DIEQO. CA 92123-1520 I—r-) 1/2'—I lO'-fl- r ALUMINUM FRAMINGS STAND-OFF SUPPORTS PIANWCW 1/4-THK. ALUMINUM BACKGROUND PANa UPUGHTS GRAPHICS ALUMINUM CABINET SQUARE TUBE FRAFJIE r THK. SWTRA PANELS CONCRETE BASE SeCTIOHVIEW CAPSTONE ADVISORS BBUSMED ALUMH* 1/8" THK. FLAT CUT OUT ALUMINUM GRAPHKS WTIH PAINTED FINISK GRAPHKS TO BE PEGGED-OFF 1/4" FROM FACE OF SIGN PANEL laUMimTED WITH EmBHAL GROUND UBHTS AS flf OUWffl. |— I'-O" • B'-O-3'-0' OPmiTC FACC LAYOUT 1/2- THX. ALUMINUM BACKGROUND PANEL WITH BRUSHED ALUMINUM FINISH- ALUMINUM STRUCTURE Wrm PAINTED RNISH TO MATCH CONCRETE BASE VA' THK. FLAT CUT OUT ALUMINUM GRAPHKS WITH PAWTED RMSH. GRAPHICS TO BE PINNED-OFF1/4' FROM TOP OF BASE STRUCTURE. lUUMINATEO WITH BACK UttHTS ASREaUIRBD. S 3/4-41/4-3 7/1B' t'-8- =S= ^~ ALUM. 5 3/4- 5- 2'.2' CAB. _i_ ADVISORS 1/8- THK. FLAT CUT OUT ALUMINUM GRAPHICS WITH PAINTED RNISH. GRAPHICS TO BE PEGGED-OFF 1/4' FROM FACE OF SIGN mNEL laUMINATED WITH EXIERKAL GROUND UGHTS AS REOUIRED. 6 3/4-1'.fl- — r-41/2-— STBEHSIDE COfJCRETE BASE wrm TEXTURED FINISH TO MATCH BUILDING soiQ NEW DOUBLE FACED MONUMENT DISPLAY - 1/2- THK. SINTRA PANELS VTHH RNISH TO MATCH -OILED TEAK-. SINTRA BVNELS TO BE WRAPPED AROUND STRUCTURAL FRAMMG AS REQUIRED SCALE: 3/4" = 1'-0" JOf IIIFIIIIMATIOH CAPSTONE ADVISORS 154S FARADAY CARLSBAD, CA SKLESPEnSOn JOHN HADAYA DESIDIIEB R. GERMAR SKnCH UD CAPSTa02 DATE 10-30-2008 HEVISIOII DATES ' 11-00-2008 RLE ' 11-20-2008 RLE ' 12-05-2008 RLE VOLTAC; VERIFY 'Rare tt diRi «**• KTCAHD (KJTiy ccj» cmixr; ico A UA-CI K CJ-Z JU KZX^L (rarijiTT a iL-wcc-n n av.;t Tz-'tjzv.'trvi ezjctw T>f CEh b ^Tisas tc K riixae-r-. a tr.tii MD P c;::t; rcjcsi ni;.-n Pago 2 of 4 CLIENT APPROVAL TEL: 858-569-1400 FAX: 85B-569-1453 9025 BALBOA AVENUE. STE 150 SANDtEGO.CA 92123-1520 31/2-21/2-CAPSTONE NEW SINGLE FACED N0N-ILLUN5NAtED FABRICATED ALUMINUM SIGN PANEL WITH APPLIED -OIL TEAKEQ- LAMINATE 1/8- THK. FUT CUT OUT ALUMINUM GRAPHBS WITH BRUSHED ALUMINUM RMSH. GRAPHICS TO BE PEGGED-OFF 1/4-FROM FACE OF SIGN WMEL OLEOTiAK BRUSHED ALUMMIU siGii NEW SINGLE FACED NON-ILLUMINArED WALL DISPLAY SCALE: 3/4" = I'-O" <0 JOB IIIFORMATIOU CAPSTONE ADVISORS 154B FARADAY CARLSBAD, CA SAlESPERtOII JOHN HADAYA DESIGNER R. GERMAR SKETCH HO CAPST002 DATE 10-30-2008 • 11-05-2008 RIG 11-20-2008 RLG ' 12-05-2008 RLG VOLTAGE VERIFY Tj,t£; EY crsKi MI VXX Id KATtI YCU1 IfCIt; li ca;::« p;::rLi. Kcn? fl r'or ca fisi r,r. -.T rc.:- -yi aai a h-vsa ti "•iirsjtvs Cf tr-rai (3i V IC taifw nicrcAi crt Ajoai orpii AFTucjvu uxJi CKrti. nc Kiijnc:: rram PHOTO LAYOUT SCALE: 3/8" = r-a" Pago 3 of 4 CLIENT APPROVAL TEL: 858-569-1400 FAX: 858-589-1453 9025 BALBOA AVENUE, STE 150 SAN DIEGO, CA 92123-1520 51/2- r-0- WMG - NEW SINGLE FACED NQN-ILLUMINAIED FABRICAIED ALUMINUM SIGN PANEL WITH APPLIED -oa. TEAKEQ- UMINATE, -1/8- THK. RM! CUT OUT ALUMINUM GRAPHICS WriH BRUSHED ALUMINUM RNISH. GRAPHICS TO BE PEGGED-Off 1/4-FROM FACE OF SIGN MN EL I 0ILH)1EAIt IBRUSHEAAUJMHUM 10 NEW SINGLE FACED NON-ILLUMINATED WALL DISPUY JDS IIIFORMATIOU CAPSTONE ADVISORS 1545 FARADAY CARLSBAD, CA SALESPERSOII JOHN HADAYA DESIONER R. GERMAR SKETCH 110 CAPST002 DATE 10-30.2008 REVISIOH DATES ' 11-OS-2008 RLG 11- 20-2008 RLE 12- 05-2008 RLG VOLTAGE VERIFY rra-ca ti cr-cRi .1 AJ.P ::rt:i':D (TCJT • *r>i c:^s fi«m.Tu n •-!. yv^rz (ca n:nz^ n^iir-.Y Casi cwiioi »Rf »y» A uAt 4 i: c-jti A: rr-z-i. IU !jfju nasi c nf air rrofiBTv cr U!,TA;»-,'J*, rl way u «"rn/r_-> rwET w rem: » war pi rAAr r;-»r*.3 ttTTUi r.- .i rt« acji E t.n\oiB In H rrtium rt A3.-^va Tirv T C -iiiriMLvi a Jir.13! (jo IE ittiUW. UCTCA;. CE- /JCCT ir-ct awjimL UJCAL cciis. Tie rcojcxi myv* (scctc i.'o cnff^ c; n-r SCALE: 3/4"^ I'-O" PHOTO LAYOUT SCALE: 1/4- = V-fl" Pago 4 ol 4 CUENT APPROVAL TEL: 858-569-1400 FAX: 858-569-1453 9025 BALBOA AVENUE, STE 150 SANDIEGO, CA 92123-1520 December 17, 2008 rCAP.STONE ADVISORS " HG CAPSTONE SIGN 0 JOB INFORMATION CAPSTONE ADVISORS 1545 FARADAY CARLSBAD, CA SALESPERSON JOHN HADAYA DESIGNER R. GERMAR SKETCH NO CAPST002 DATE 10-30-2008 REVISION DATES 11-06-2008 RLG 11- 20-2008 RLG 12- 05-2008 RLG 12-18-2008 RLG VOLTAGE VERIFY PRIMARY ELECTRCAl TO SIGN LOCATKINS IS TO BE PROVIDEO BY OTHERS 20 AMP DEDKATID CIRCUITIS) WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR ALL INSTALUTKINS COLORS REPRESENTED IN THIS DRAWING ARE FDR PRESENTATKIN PURPOSES ONIY THEY WILL NOT MATCH YDUR HNISHED PRODUCT PERFECTLY COLOR CALL0UT5 ARE FOR A MATCH AS CLOSE AS POSSIBLE THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF ULTRASIGNS IT CANNOT BE REPRODUCED. COPIED DR EXMBITEO IN WHOLE OR PART WFTHOUT RRST OBTAINING WRRTEN CONSENT FROM ULTRASIGNS THE SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICIE 600 OF TRE NATXINAL ELECTRK^AL CODE AND/OR OTHER APPLKyVBLE LOCAL CODES THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN Page 1 of 3 CLIENT APPROVAL TEL: 858-569-1400 FAX: 858-569-1453 9025 BALBOA AVENUE, STE 150 SAN DIEGO, CA 92123-1520 10'-0" LIGHT SOURCE WITH CLEAR PLEX LENS 1" THK. SINTRA PANELS 1'-41/2" 1" ALUMINUM FRAMING & STAND-OFF SUPPORTS WITH PAINTED BRUSHED ALUMINUM FINISH • 11 1 1 ^ 1 r—^ §1— [1 ^ PLAN VIEW 1" THK. ALUMINUM BACKGROUND PANEL. PAINT MATTHEWS BRUSHED SILVER UPUGHTS F.C.O. GRAPHICS ALUMINUM CABINET PAINT MAHHEWS BRUSHED SILVER SQUARE TUBE FRAME. PAINT MATTHEWS BRUSHED SILVER 1" THK. SINTRA PANELS CONCRETE BASE December 17, 2008 TO MATCH PMS 300 BLUE WHITE PAINT TO MATCH "OILED TEAK" ON SIGN "Cl: PAINTED BRUSHED SILVER SECTION VIEW 10'-0" CAPSTONM VJVIG: ADVISORS VJVIG: 1/8" THK. FLAT CUT OUT ALUMINUM GRAPHICS WITH PAINTED FINISH. GRAPHICS TO BE PEGGED-OFF 1/4" FROM FACE OF SIGN PANEL. ILLUMINATED WITH EXTERNAL GROUND LIGHTS AS REQUIRED. - V-O" 6'-0" 3'-0" OPPOSITE FACE LAYOUT ALUMINUM STRUCTURE WITH PAINTED FINISH TO MATCH CONCRETE BASE 1/4" THK. FLAT CUT OUT ALUMINUM GRAPHICS WITH PAINTED FINISH. GRAPHICS TO BE PINNED-OFF 1/4" FROM TOP OF BASE STRUCTURE. ILLUMINATED WITH BACK LIGHTS AS REQUIHED. JOB INFORMATION CAPSTONE ADVISORS 1545 FARADAY CARLSBAD, CA SALESPERSON JOHN HADAYA DESIGNER R. GERMAR SKETCH NO CAPST002 DATE 10-30-2008 REVISION DATES 11-06-2008 RLG 11- 20-2008 RLG 12- 05-2008 RLG 12-18-2008 RLG VOLTAGE VERIFY PRIMARY ELECTRICAL TO SIGN LOCATIOfIS IS TO BE PROVIDED BY OTHERS 20 AMP DEDKATEO CIRCUIT(S) WITH NC SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR ALL INSTALLATXINS COLORS REPRESENTED IN THIS DRAWING ARE KIR PRESENTATION PURPOSES ONIY THFY WIU NOT MATCH YOUR RNISHED PRODUCT PERFECUY COLOR CAUOUTS ARE FOR A MATCH AS CLOSE AS POSSIBIF THIS ORIGINAL DESIGN IS THE SOLE PROPERTY OF ULTRASK3NS II CANNOT BE REPRODUCED, COPIED OR EXHIBTTED. IN WHOLE OR PART. WITHOUT RRST OBTAINING WRRTEN CONSENT FROM ULTRASKiNS THE sm IS INTENDED TO BE INSTALLED IN ACCORDANCE WRH THE REQUIREMENTS OF ARTXU 600 OF THE NATIONAL ELECTRKML CODE AND/OR OTHER APPlKmE LOCAL CODES THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SH5N. Page 2 of 3 CLIENT APPROVAL STREETSIDE CONCRETE BASE WITH TEXTURED FINISH TO MATCH BUILDING SIGN 0 NEW DOUBLE FACED MONUMENT DISPLAY 1/2" THK. SINTRA PANELS. FWNTTO MATCH "OILED TEAK" ON SIGN "Cl". SINTRA PANELS TO BE WRAPPED AROUND STRUCTURAL FRAMING AS REQUIRED SCALE: 3/4" = 1'-0" •=n=i^j=ii^.w.i-mjrhjiHiJu TEL: 858-569-1400 FAX: 858-569-1453 9025 BALBOA AVENUE, STE 150 SAN DIEGO, CA 92123-1520 December 17, 2008 1 1/2" 2'-0" 1'-9" 3'-0" 1 5/8" 3 1/4" 21/2" I^SOB" CAPSTONE ADXISORS I'-O" NEW SINGLE FACED NON-ILLUMINATED FABRICATED ALUMINUM SIGN PANEL WITH APPLIED "OIL TEAKED" LAMINATE 1/8" THK. FLAT CUT OUT ALUMINUM GRAPHICS WITH BRUSHED ALUMINUM FINISH. GRAPHICS TO BE PEGGED-OFF 1/4" FROM FACE OF SIGN PANEL 4'-2" OILED TEAK BRUSHED ALUMINUM SIGN 0 NEW SINGLE FACED NON-ILLUMINATED WALL DISPLAY SCALE: 3/4" = I'-O" PHOTO LAYOUT JOB INFORMATION CAPSTONE ADVISORS 1545 FARADAY CARLSBAD, CA SALESPERSON JOHN HADAYA DESIGNER R. GERMAR SKETCH NO CAPST002 DATE 10-30-2008 REVISION DATES 11-06-2008 RLG 11- 20-2008 RLG 12- 05-2008 RLG 12-18-2008 RLG VOLTAGE VERIFY SCALE: 3/8" = I'-O" PRIMARY ELECTRICAL TO SIGN LOCATIONS IS TO BE PROVIDED BY OTHERS 20 AMP DEDICATED CIRCUIT(S1 WTRI NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR ALL INSTALLARONS COLORS REPRESENTED IN THIS DRAWING ARE FOR PRESENTAOON PURPOSES ONOf THEY WIU NOT MATCH YOUR RNISHED PRODUCT PERFECTLY COLOR CALLOUTS ARE EOR A MATCH AS CLOSE AS POSSIBLE THIS ORKjINAL DESIGN IS THE SOLE PROPERTY OF ULTRASK3NS R CANNOT BE REPRODUCED, COPIED OR EXHIBREO, IN WHOLE OR PART, WITHOUT RRST OBTAINING WRRTEN CONSENT FROM ULTRASKSNS THE SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WRH THE REQUIREMENTS OF ARTKLE 600 OF THE NATWNAL ELECTRICAL CODE AND/OR OTHER AFPLKMBLE LOCAL CODES THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN Page 3 of 3 "OIL TEAK" SPECIFICATIONS: VENEER FROM "FROST HARD WOODS" 6565 MIRAMAR ROAD, SAN DIEGO, CA (858) 455-0455 NOTE: CONFIRM WITH FROST THE TYPE OF GLUE ADHESIVE REQUIRED TO MOUNT THE VENEER TO ALUMINUM CLIENT APPROVAL mm j^Jrii^-i^ i.ifjd.LJMiJi^ TEL: 858-569-1400 FAX: 858-569-1453 9025 BALBOA AVENUE, STE 150 SAN DIEGO, CA 92123-1520