Loading...
HomeMy WebLinkAboutPS 10-45; Chase; Sign Permits/Programs (PS)CITY Of CARLSBAD REVIEW FOR SIGN PERMIT P-11 Development Services Planning Department 1635 Faraday Avenue, (760) 602-4610 www.carlsbadca.gov PUNNING APPLICATION # P3 REC'D BY (2f^ DATE g^'ll-jO SIGN FEE SIGN PROGRAM FEE RECEIPT NO. All plans submitted for sign permits/sign programs shall consist of a minimum of a site plari and sign elevations containing the following Information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(5). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be conslructed of. C. Source of Illumination. D. Proposed sign copy. APPUCANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT:. ADDRESS OF PROJECT: 9\ (klXU.nn NkfllJ. ASSESSOR PARCEL NUMBER: RELATED PLANNING CASE NUMBER(S): TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel (g) Theater (b) Commercial (e) Service Station (h) Gov't/Church (c) Office/Industrial (f) Prof. Care (1) Public Park SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Ye; (I) Produce Stand (k) Nursey <l) P-U/OS Zone VILUi^GE REDEVELOPMENT AREA YesD NoD Specific Plan Number NoQ Requires VR Approval p-11 page 1 of 4 Revised 04/09 SIGN ORDINANCE: YesQ NoD COASTAL ZONE: YesD NoQ EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended Directional Canopy Freestanding (Project Identity) PEFlMiTS ISSUED FOR EXISTING SIGNS: YesD NoD PROPOSED PERMANENT SIGNS: Date TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Pole" Monument** - Wall \ Suspended Directional Canopy Freestanding'* (Project Identity) PROPOSED TEMPORARY SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Construction** For Sale** Banner **Prior to approval, ali proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this appiication showing how the proposed signage wili not encroach into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. p-11 Page 2 of 4 Revised 04/08 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for ail pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signft-must be reviewed for potential issues by the Traffic Engineering Department, which wiii not allow stons to ba approved over the counter. Additional lime will be required for on-site inspection. Show building/$ P/L V Shaw all property lines , Sight Distance Requirement Show setbacks from all curbs curb line Sight Visibility Street Nam8($) ® North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that It Impairs tlie sight distance requirements at any pubiic or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN_ p-11 Page 3 of 4 _sq. ft. .sq. ft. . sq. ft. . sq. ft. . sq. ft. . sq. ft. Revised 04/06 PROPERTY OWNER APPLICANT "1 NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) MAILING ADDRESS MAILING ADDRESS CITY AND STATE ZIP TELEPHONE CITY AND STATE ZIP ^0-?5&t> TELEPHONE > ll5i>r^Df€ (Ik 1 CERTIFY THAT 1 AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. 1 CERTIFY THAT 1 AM THE REPRESENTATIVE 1 OF THE LEGAL OWNER AND THAT ALL THE f ABOVE INFORMATION IS TRUE AND t CORRECT TO THE BEST OF MY KNOWLEDGE. | 1 SIGNAIWE OATE •STGNATURE " / DATE | PLANNER CHgCK LIST: 1. 2. 3. 4. 6. 6. Field check by planner. Within maximum length, area. Style consistent wrfth Sign Program and/or Specific Plan criteria, if applicatrfe. Location: • In right-of-way • In visibility triangle at corner Pole and monument signs to be checked by Traffic Engineering, for visibility Issues. When approved route copy to Data Entry APPROVED: Plannei^ (^^^ Date:_^l!4lP p.11 page 4 of 4 Revteed 04/09 06/03/^10 06:32 CITY OF S.D./D.S. CflSHIERS 917607966360 N0.B59 P001 THE CITY OF SAN DIECSO Temporary Service Guidelines The City of San Diego liispcotion Services Division has generated this list of )»immu a requiiements for providing tenspoaiy power to a building's pennansnt cJecfrical servie« eqdpiiient in&wn aS 'TSPB" meter release for residential projects and Test" meter release fbr commercial projects. Other conditions for approval may be required depending on the imique circumstances of the projecL 1. A letter is required &<m thc general contractor aild the owner or tenant that ir sludes tibe following items: a. The system or equipment that requires tcmporaiy electridal power and th ? reason tiiat the eariy release for power is necessary, b. The vmderstanding that tbis moter.rt>leafie is not an approval for any type | f occiqjanoy; o. The understanding that no electrical ciimit or feeder is to be energized T)i^£mt the prior written approval ofthe elcohSoal inspeotOT. 2. Tho buildmg or Structure coostruction must be in at thc following stage: a. The roof and all exterior waU coverings must be complete (tiie building ^r structure is "dried-in") b. The elcotrioal utility service room must be oomplete and capable of bein^ secured ftom unauthorized access; o. All rooms or aiieae containing ener^ed electrical equipment must be cai^le of being secured fiom unauthorized personnel,- d. All lequiied fire suppression systems m the area to be energized must be |ipcxational or a construction fire plan shall be in place 3. Hie following parts of the electrical system must be completely installed an^ inspected: a. The main electrical service equipment including any required approved tfiird-pariy testing of the equipment aad submittal ofthe report to the electrical inspector Q^Jot<; testing is required for required gtound-feult protection for eqttip)»e»t and for phase testhigx f service bus and unmetered feeder bus); b. The elecbical wMng tqr the system or equipment that will be emeigiaed; 4. Any electrical equipment that will be euergized must be capable of being se 5. A written loclc-oirtitag-out procedure must be ill place 6. Any required inspections ofthe specified areas by Stmctural, Mechanical, Fife and State Elevator Inspectors must bo approved. This Is a generic list and may not contahl all of the requirements for your p complete list can be generated when the project drawhigs have been reviewed by inspector or by tho senior electrical inspector. Refer to the Municipal Code for Xmpomy electrical pennit legulatioas. Inspection Services • Development Services Deporhne «01 Wilselmw court, $«» m, MS 1102-8 • SM Ofejo, ^ Id l$$8) 492-5070 Fw (858) 4n-5l)9a •project. A more le electrical nf City of Carlsbad Faraday Center Faraday Cashiering 001 1016501-3 06/14/2010 96 Mon, Jun 14, 2010 02:33 PM Receipt Ref Nbr: Rl016501 -3/0032 PERMITS - PERMITS Tran Ref Nbr: 101650103 0032 0034 Trans/Rcpt#: R0079764 SET #: CB101061 Amount: 1 § $109.28 Item Subtotal; $109.28 Item Total: $109.28 PERMITS - PERMITS Tran Ref Nbr; 101650103 0032 0035 Trans/Rcpt#; R0079763 SET #; PSI00045 Amount; 1 1 $56.00 Item Subtotal; $56.00 Item Total: $56.00 2 ITEM(S) TOTAL; $165,28 Check (Chk# 101018) $165,28 Total Received: $165,28 Have a nice day! **************CUSTO!«]ER COPY************* City of Carlsbad 163 5 Faraday Avenue Carlsbad CA 92008 liiiiiniiiiiiiiiiiiiiii Applicant: AKC SERVICES Description PS100045 766 0 EL CAMINO REAL CBAD Amount 56 . 00 Receipt Number: R0079763 Transaction Date: 06/14/2010 Transaction ID: R0079763 Pay Type Method Description Amount Payment Check 56.00 Transaction Amount: 56.00 CHASE O Sign Legend page 3 Site 14862 - Carlsbad Albertsons 7660 El Camino Real Carlsbad, CA Sign Type Description 1 LIF-BLK-20 20"llluminated Channel Letterset 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Land Lord Approval Initial Here Additional Comments SIGN PERMIT NO. PS jf) 'M^ PLANNING BUILDING APPROVED BY DATE SignResource Buildino vour coroorale idenlilv.. alwavson laroel Building your corporate idenlily always on target 6135 District Blvd. • Maywood, CA 90270 800.423.4283 • Fax 323.560.7143 Website; www.signresource.com CHASE O Site Overview page 4 Site 14862 - Carlsbad Albertsons 7660 El Camino Real Carlsbad, CA West Elevation LIF-BLK-20 / Illuminated Black Letterset with Octagon Land Lord Approval Initial Here Additional Comments SignResource 6135 District Blvd. • Maywood, CA 90270 800.423.4283 • Fax 323.560.7143 Website: www.signresource.com CHASE O 4.5" n ?0' ITS 1/2" CHASE LIF-BLK-20 / Illuminated Black Letterset with Octagon 25.61 sq. ft. used - 35 sq. ft. Allowable 1/2" 2'-2 1/4' Sign Details page 6 Site 14862 - Carlsbad Albertsons 7660 El Camino Real Carlsbad, CA 37'-3 3/76 West Elevation - Current Condition West Elevation - Proposed Recommendation Land Lord Approval Initial Here Additional Comments SignResource ^^^^ Riiildina vnur corttoratt* idantitv nlwava on taraat Building your corporate identity. . . always on target 6135 District Blvd, • Maywood, CA 90270 800.423.4283 • Fax 323.560.7143 Website: www.signresource.com ir-81/2' 8'-ll' MOINTING LOCATION TYP. 7/ ^ 1/4' ELEVATION < MOUNTING LOCATIONS ALUMINUM RETURNS PAINT TO MATCH MATTHEliJS -MP-18101 CHASE NICKEL, GLOSS .IIT ATOGLAS •3(2>63 P85tn ("MATTE FACE OUT; li)/ (2) LAYERS OF 3M •SfeSS-IO UJHITE DIFFUSER FILM APPLIED SECOND SURFACE ALUMINUM BACK PAINT TO MATCH MATTHEIUS •MP-18I01 CHASE NICKEL, GLOSS .125' THERMO-FORMED ARISTECH •6046 TRANSLUCENT BLUE ACRYLIC LUEDGE FACE TYP. ALUMINUM RETURNS < BACK PAINT TO MATCH MATTHEIUS •MP-I8I01 CHASE NICKEL, GLOSS NOTES: 1. Design is based on 90 mph 3 sec gust design oiind speed per IBC 2006. Exposure C. 2. No additional mind catching surfaces are added to the building structure, the customer's building engineer is to determine the adequacy of the supporting structure. 3. Aluminum shapes shall be extruded from 6061-T6 alloy. Aluminum sheet shall be 3003-HI4 alloy. Aluminum plate shall be &052-M34 alloy. 4. All fasteners shall be stainless steel or otherwise coated to prevent corrosion. b. All luall penetrations shall be sealed to prevent mater intrusion. b. This design is prototypical and should not be used for site specific applications unless deemed suitable by a competent i=tofessional Engineer. 3D VIEIU OF OCTAGON SIDE VIEIU OF CHANNEL LETTER SIDE VIEIU OF OCTAGON CHASEO These documents represent protot)pical design drawings erected specifically for use by J.P. Morgan Chase. Use of this unpublished work for any purpose other than the intended application is strongly discouraged. Disclosure or reproduction of any of the information contained within these documents without the written consent of the owner is strictly prohbited SHT. OF BY: TMD DATE: 1/28/09 Project No. 08-1218 Drawing No. B24404E. REV. 5/14/09 4/24/09 4/23/09 4/15/09 DATE ADDED 8ECCM3 LATBR CF DFRJSB! HU1TOl£nERF»CE CHW Mca » <n>u* om. Aun Mac oiu..air men «w TO JU*. ow <un pnm e«i.aiT ncn M-lojw, o«p—cwcitinf''imwiiLiiiaiw^cwn tOOBS 6ECaO UTIR CF DmesK TO •cHAgF i£nBgr>>ca OmSED TOTAL OTT CF POlBt SUPPLB A>0 lUKHi DUflRAM CHAN3ED WnW BAOC PAMT COLCR won w-BBM TO ty-wa DESCRIPTION TRR TMD TRR TMD TMD BY: APR- GRAPHICS DEPICTED ARE FOR ILLUSTRATIVE PURPOSES ONLYI USE ONLY APPROVED ARTUJORK FOR PRODUCTION. ALL EXPOSED FASTENER HEADS SHALL BE PAINTED TO MATCH THE EXTERIOR CABINET FINISH DESIGNATION: LIF-BLK-20-LED m B] Bl B] B] BIOEI V a i 7 MOUNTING LOCATION TYPICAL ELECTRICAL ENTRANCE TYP. B] Bl B] Bl Bl BlOB Bl El Bl B Bl B B Bl B B B BO 7 B] B B B BOB B B B B B B B Bl B B B B B 32) B B B B B B B ^ Bl Bl Bl Bl Bl BIO m \B m m BE K B m o BE GB QS DS OS OS IBS . B BB Bi m m IB 23 LED'S 21 LED'S 21 LED'S PERMLIGHT 1&3-IUHT TIUISTER STAR LED 29 LED'S TYPICAL 30 LED'S 84 LED'S . ELECTRICAL REQUIREMENTS: LEDS: C220; PERiLlGHT 1&3-UJHT TUJISTER STAR POUER SUPPLY: (2) PERMLIGHT 60-I2DA « OJhbA TOTAL LOAD: 13A fi 120V CIRCUITS: ri; 20 AMP REO'D. LED LAYOUT CFACES REMOVED FOR CLARITY; ALL PRIMARY 4 SECONDARY LUIRING MUST BE GROUNDED PER ALL APPLICABLE UL AND NEC GUIDLINES 1/2' SEAL-TITE ELECTRICAL CONNECTOR THROUGH UJALL BUILDING UJALL POLUER SUPPLY IN ENCLOSURE TYPICAL 1/2' STRAIGHT CONDUIT CONNECTOR TYP. 20 AMP DISCONNECT SUJITCH UJITH UJEATHERPROOF GANG LEVER COVER 1/2' ELECTRICAL CONDUIT TYP. UJIRING DIAGRAM o These documents represent prototypical design drawings created specifically for use by J.P. Morgan Chase. Use of this unpublished work for any purpose other than the intended application is strongly discouraged. Disclosure or reproduction of any of the information contained within these documents without the written consent of the owner is strictly prohibited. SHT. OF BY: TMD DATE: 1/28/09 Project No. 08-1218 Drawing No. B244045 A 1/20/09 ADDED aeCCM? UTER CF DRuee? FUJI TO LETtW FACE TRR K A 6/14/09 o<K> MX ro AroauM oan Jun Bioc oiu.-air nm t^jomr.amMmmtmcju.-aBmcnMmme: oac ucMcJL eoMcno) ncn uoB ro aiiL Ttni «t«D <* BouL ro <au.<»ir < ADWP •Mew Mon TMD K A 4/24/09 ADDED «ECCK> LATD! CF DFHISER TO-cmarLETiBeFAca TRR K A 4/23/09 CHANGED TOTAL OTT CF |>CU« eum.E6 AND UnC DiAQRAM TMD K A 4/15/09 OIANQED renw MC BACK P»AWr COLOR FNCM tp-«e9i TO n'-tewi TMD HC REV. DATE DESCRIPTION BY: APR: GRAPHICS DEPICTED ARE FOR ILLUSTRATIVE PURPOSES ONLYI USE ONLY APPROVED ARTUJORK FOR PRODUCTION. DESIGNATION: L1F-BLK-20-LED 1' JEUJELITE METALLIC SILVER TRIMCAP .IIT ATOGLAS •3063 P9&m CMATTE FACE OUT; Wi/ (2) LAYERS OF 3M •3635-10 UJHITE DIFFUSER FILM APPLIED SECOND SURFACE .063' ALUM. LETTER BACK PERMLIGHT 153-UJHT TUJISTER STAR LED TYPICAL 1/2' SEAL-TITE STRAIGHT CONDUIT CONNECTOR 1/4" DIA. DRAIN HOLE TYP. 3' •8xl/2'PAN-PHILLIPS HEAD THREAD ROLLING SCREUJ fi 12' O.C. MAX. 0bO' ALUM. RETURN UJELDED TO LETTER BACK .111' ATOGLAS •3063 P95m CMATTE FACE OUT; UJ/ (2) LAYERS OF 3M ^3635-10 UJHITE DIFFUSER FILM APPLIED SECOND SURFACE J063' ALUM. LETTER BACK 0 .125' THERMO-FORMED ARISTECH •6046 TRANSLUCENT BLUE ACRYLIC UJEDGE FACE CHEMICALLY BONDED TO 3/4' CLEAR ACRYLIC FACE TYP. 3/4' CLEAR ACRYLIC FACE CHEMICALLY BONDED TO UJEDGE FACE FABRICATE FROM i2)90' ALUM. (4 REO'D; tl FORMED .050' ALUM. DRAIN HOLE COVER TYP. 1/4' DIA. DRAIN HOLE TYP. TYPICAL SECTION THROUGH CHANNEL LETTER 1/2' ' 2 1/8' LOGO CABINET BRIDGE DETAIL These documents represent prototypical design drawings created specifically for use by J.P. Morgan Chase. Use of this unpublished work for any purpose other than the intended application is strongly discouroged. Disclosure or reproduction of any of the information contained within these documents without the written consent of the owner is strictly prohtoited. SHT. OF BY: TMD DATE: 1/28/09 Project No. 08-1218 Drawing No. B244045 A 1/20/09 ADDED eECOO LATER CF DFTUSa nr\ TO LETTW FAC« TRR IK A 6/14/09 oav Ud m AKOLM am. MJti •*« ciuoir men tfmrroMr.am Minmum cJti.<ui wen 0W10 mf, ow ucmon emaenai ncn UHD » m < «c<s> CK •OUL ro i«.n cia^ui 1 jooB> mimest Ncn TMD IK A 4/24/09 ADDED eeCCN3 LATER CF OfKBEK TO xmee- LETTER FACES TRR K A 4/23/09 aVMED TOTAL OTT CF POUeR aUPTLES AK? une DUURAM TMD IK A 4/15/09 CH4N3ED RETIHN MO BACK PAMT COLOR FROM ^r-isas TO *r-w« TMD IK REV DATE DESCRIPTION BY: APR: .063' ALUM. BACK •8x1/2' COUNTERSUNK FLAT- PHILLIPS HEAD THREAD ROLLING SCREUJ fi 12' O.C. MAX. iZ)90' ALUM. RETURN 3/4' CLEAR ACRYLIC FACE SHOULDER CUT AS SHOUN CHEMICALLY BONDED TO UJEDGE FACE .125' THERMO-FORMED ARISTECH 6046 TRANSLUCENT BLUE ACRYLIC UJEDGE FACE CHEMICALLY BONDED TO 3/4' CLEAR ACRYLIC FACE TYP. FABRICATED J2>90' ALUM. BRIDGE UJELDED TO CABINET RETURNS C4 REO'D; 1/2' SEAL-TITE STRAIGHT CONDUIT CONNECTOR ALL ACRYLIC ASSEMBLIES SHALL EMPLOY A SOLVENT TYPE CEMENT FOR INITIAL RAPID ASSEMBLY FOLLOUJED BY A MONOMER-POLYMER-SOLVENT CMPS; TYPE CEMENT AROUND ALL BONDED EDGES. INTERIOR SURFACES OF ALL ALUMINUM RETURNS < BACKS SHALL BE PAINTED 6PRAYLAT STARBRITE UJHITE UNLESS OTHERUJISE NOTED. J050' ALUM. RETURN UELDED TO j050' ALUM. BACK SECTION THROUGH OCTAGON GRAPHICS DEPICTED ARE FOR ILLUSTRATIVE PURPOSES ONLYI USE ONLY APPROVED ARTUJORK FOR PRODUCTION. DESIGNATION: LIF-BLK-20-LED 3 1/2' 4 5/8' 3 1/2' SECTIONS FOR FRAMED UJALL INSTALLATION NOTE: PIPE SPACER MAY BEAR ON UJALL SHEATHING ONLY IF THE SHEATHING IS 1/2' THICK PLYUJOOD OR GREATER IF THE UJALL SHEATHING IS PLYUJOOD THAT IS LESS THAN 1/2' THICK OR IS ANYTHING OTHER THAN PLYUJOOD, THE PIPE SPACER SHALL BE EXTENDED TO BEAR ON THE UJOOD BLOCKING BEHIND. 4 5/8' SECTIONS FOR BRICK UJALL INSTALLATION 1/2' DIA. PIPE SPACER FROM BACK OF LETTER TO FACE OF BLOCKING TYP. 3/8' DIA. A301 BOLT UJITH NUT, FLAT I LOCK UJASHERS TYP. EXTERIOR FINISH UJALL SHEATHING 2x4 UJOOD BLOCKING BETUIEEN STUDS. ATTACH BLOCKING AT EACH END TO STUDS. n UJALL STUD ON 16' CTRS. BRICK EXTERIOR UJALL SHEATHING UJALL STUD ON 16' CTRS. TYPICAL FRAMED UJALL MOUNTING DETAIL 3/8' DIA. HILTI HLC-HX SLEEVE ANCHOR OR EOUAL UJITH 1 1/4' MINIMUM EMBEDMENT TYP. TYPICAL BRICK UJALL MOUNTING DETAIL CHASE O These documents represent prototypical design drowings created specifically for use by J.P. Morgan Chose. Use of this unpublished work for any purpose other than the intended application is strongly discouraged. Disclosure or reproduction of any of the informotlon contained within these documents without the written consent of the owner is strictly prohibited. SHT. OF BY: TTiD DATE: 1/28/09 Project No. 08-1218 Drawing No. B244045 A 1/20/09 ADDED tecac LATER OF DIWSER FUJI TO LETTER FACE TRR IK A 6/14/09 CMK> Mf* ro «naiAt MU oac 4un Booc oia.aff moi mfmmy,aupMmmtmeMi.-aamenMrmme: cw> mjcnacM. coMcnoi mi LMUD ro »«. tm < Ol MM. ro c«i.<ur < «c«x> pn aucai Non TMD IK A 4/24/09 ADDED «eCOM? UTW CF DP«0! TO •CHA8E' LETIW FACES TRR IK A 4/23/09 CU*eED TOTAL OTT CF POIW SUPTLES AH3 UlRWa DlAflRAM TMD IK A 4/16/09 CWANSED RETUW A^O BACK PAHT COLOR FKXi <tr-Ke^ TO vp-te^ TMD IK REV DATE DESCRIPTION BY: APR: GRAPHICS DEPICTED ARE FOR ILLUSTRATIVE PURPOSES ONLYI USE ONLY APPROVED ARTUJORK FOR PRODUCTION. HILTI SLEEVE ANCHOR SYSTEM OR EQUAL SHALL BE INSTALLED IN STRICT ACCORDANCE UJITH THE MANUFACTURER'S SPECIFICATIONS 4 RECOMMENDATIONS DESIGNATION: L1F-BLK-20-LED