Loading...
HomeMy WebLinkAboutPS 11-85; Viet Grill; Sign Permits/Programs (PS)~ t .. .. (,. .. , ···~CITY OF CARLSBAD REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS· OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks NAME OF PROJECT: \} te± ~-Q \ ' ADDRESS OF PROJECT: .:2_'7 08 loQu~/C f\L~. # (04; ((·, f( S}y-~_&1 (/} ASSESSOR PARCEL NUMBER:~:::;.;;....;;;.O__,.q_-_0_0----"1_-_4#.....;..__4:(....._ _______ _ RELATED PLANNING CASE NUMBER(S): --------------- TYPE OF DEVELOPMENT: (a) Residential (b) Commercial (c) Office/Industrial SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA (d) Hotel/Motel (e) Service Station (f) Prof. Care (g) Theater (h) Gov't/Church (i) Public Park 0) Produce Stand (k) Nursey (I) P-UlOS Zone Ye~ NoD Specific Plan Number ____ _ VILLAGE REDEVELOPMENT AREA Yes0 Nf~ Requires VR Approval P-11 Page 1 of4 Revised 07/1 0 SIGN ORDINANCE: YesD NoD COASTAL ZONE: YesD NoD EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall \ _2l .~C9.. ·r \ 'FS {l Suspended Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: YesD NoD Date ------- PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT .· :.Poe~· Monument** Wall \ l ,;2\ ,~iJLr;: .;2\,S~~ \~('I \ c, {/( {-'"<}l Suspended Directional Canopy Freestanding** (Project Identity) PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Construction** For Sale** Banner **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of4 Revised 07/10 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I I I PIL • Sight Distance Requirement • I • • I Show building/ s • • : I • • I , 4 I • • • ,_ ---l Show setbacks from all curbs --- I • • I • I I • • I • I Show all property lines I • • PIL I • • I • ' • I I • • curb line • • • • • • • ----------~-- Sight Visibility I Street Name(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any p~destrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA TOTAL BUILDING STREET FRONTAGE ____ d.~A=--) ___ sq. ft. TOTAL SIGNAGE ALLOWANCE ---------sq. ft. EXISTING SIGNAGE (SQ. FT.) ---------sq. ft. REMAINING SIGN ALLOWANCE AT PRESENT ---------sq. ft. PROPOSED SIGNAGE (SQ. FT.) ---------sq. ft. REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN ________ sq. ft. P-11 Page 3 of4 Revised 07/10 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) ~\\ l\ ··ye_\ \e~(_"l''/ ·t ,, \~.t :s~~u C<:s~rr~ MAILING ~-!>DRESS f.i2£~o MAILING ADDf:l.~SS . #-~l-1 9'l(l'1 Wb:-YL. ~ '7c1Z.'.3> lUc:LHW·-f1-."(_ ~ CITY AND STATE ZIP TELEPHONE CITY AN~ sr~TE. z~~~~ TELC1'/$~ 1 ~:t.~ (ke"'\13 ) CA-l~sca)~\~s '-' +lLLv'Cl'l·~~tJ)) Gea..G.<L-1 cf\ )·· .. 72(;~ I CERTIFY THA t-1 AM THE LEGAL OWNER I CERTIFY r-FfAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION IS OF THE LEGAL OWNER AND THAT ALL THE TRUE AND CORRECT TO THE BEST OF MY ABOVE INFORMATION IS TRUE AND KNOWLEDGE. CORRECT TO THE BEST OF MY KNOWLEDGE. f ~-cr.:{~~Lo&-) c~-==~=~-=~--~; \ J \J SIGNATURE / DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consjstent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: •!• In right-of-way •!• In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry Dateft -/-U P-11 Page 4 of4 Revised 07/10 City of Carlsbad Faraday Center Faraday Cashiering 001 1124401-1 09/01/2011 32 Thu, Sep 01, 2011 01:49PM Receipt Ref Nbr: R1124401-1/0017 PERMITS -PERMITS Tran Ref Nbr: 112440101 0017 0019 Trans/Rcpt#: R0086182 SET#: CB111900 Amount: Item Subtotal : Item Total: ITE~1(S) TOTAL: Cash Total Received: CHANGE: Have a nice day! 1 @ $92.29 $92.29 $92.29 $92.29 $100.00 $100.00 $7. "11 **************CUSTOMER COPY************* City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 11111111111111111111111111111111111111111111111111111111111111111 Applicant: I2I SIGNS CORP Description Amount PS110085, 57.00 2708 PALOMAR AIRPORT RD CBAD Receipt Number: R0086180 Transaction ID: R0086180 Transaction Date: 09/01/2011 Pay Type Method Description Amount Payment Check 57.00 Transaction Amount: 57.00 I2iSigns Corp. Mail-FW: Viet GRILL Signage Approval https://mail.google.cotrlmail/u!O/?ui=2&ik=Ob7ba633ef&view=pt& ... i2i5igns Info <info@i2isigns.com> FW: Viet GRILL Signage Approval 1 message Kelly Telleson <ktelleson@spectrummgt.com> To: info@i2isigns.com Wed, Aug 24, 2011 at 6:15PM You have Landlord approval for this sign subject to our receipt of a copy of the approved City sign permit. Please forward a copy to me for my files at your earliest convenience. Thank you, Kelly Telleson Property Manager Spectrum Property Management 8799 Balboa Avenue #260 San Diego, CA 92123 858-569-8799 X 16 Fax: 858-569-8781 ktelleson@spectrummgt.com From: i2iSigns Info [mailto:info@i2isigns.com] Sent: Sunday, August 14, 2011 8:48PM To: Kelly Telleson Cc: Henry Nhan Subject: Viet GRILL Signage Approval Hi Kelly, Please fmd the attached Viet GRILL signage layout for your review & approval. If you have any questions, please feel free to contact Andrew T. at (714)91-7267. Best Regards, AndrewT. CLIENT Viet Grill ADDRESS 2708 Loker Ave. #1 04 Carlsbad, CA 92010 LOCATION ELEVATION 24' DATE: 08-15-11 I CONCEPT. A 1234 I SALES AQTf DRAWN BY KL SIGN PERMIT NO.-s"t f--.-as- CUSTOMER APPROVAL LANDLORD APPROVAL SIGNATURE DATE SIGNATURE DATE WE HAVE REVIEWED AND APPROVED THE SIGN DETAILED HEREIN TO BE FABRICATED PER THE SPECIFICATIONS SHOWN ON THE DRAWING 'TMIIQn iS ~k)be mtdtd n eecor~ Wlf'l lhtr~tld A.rk .. 501 of the NJitional EIKtric:al Codt .,...Ot ot. applcable local codes 1M flck.ldn proper groundtng 1nd _ ..... _ Contractors Lie. #917099 ~~~~~IGNS Cr®~~iV® ur~PhiC ~C9LU~1<9n& 7923 Warner Ave. #M Huntington Beach, CA 92647 {714)848-9616 Phone (714)203-9690 Fax PAGE 1 OF 2 Website: www.ilisigns.com Email: ilisigns@gmail.com COMMENTS: [JJ 62-\. 8-S f [I] lil SCALE: 1 /8" = 1' NOTE: This is an original drawing, created by i2i Signs Corp. It is submitted for your personal use in connection with a project being planned for you by i2i Signs. It is not to be show to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion. Any printed colors on drawing are approximate. 18"x30" R 14' SPECIFICATIONS 1. MANUFACTURE AND INSTALL ONE SET OF ILLUMINATED CHANNEL LETIERS 2. FACES: -COLOR "Viet" TO BE 1 /8" WHITE ACRYLIC W/ TRANSLUCENT GREEN VINYL -COLOR "OVAL LOGO" TO BE 1/8 WHITE ACRYLIC W/ DIGITAL PRINTED VINYL -COLOR "GRILL" TO BE 1 /8" WHITE ACRYLIC W/ TRANSLUCENT ORANGE VINYL -3/4 RED & BLACK TRIM CAP 3. RETURN: -5" DEEP PAINTED GLOSS BLACK 4. ILLUMINATION: WHITE 12 vdc LED LIGHT UNITS-SPACING: 2.5 UNITS/STROKE INCH 5. CHANNEL LETIERS SHALL BE MOUNTED DIRECTLY ON THE EXISTING STUCCO WALL WITH NON-FERROUS FASTENERS LAG BOLTS 1 /4" x 1-1 /2" PER LETIER (4) MIN. -i2 f- 6. ALL WIRING AND COMPONENTS TO BE UL APPROVED. 7. TRANSFORMER TO BE UL LISTED 12-500 WATI AS NEEDED-DISCONNECT SWITCH ~ 8. UL LISTED 18AW G WIRE 9. EXISTING STUCCO WALL 5'x24' -i4 CLIENT Viet Grill CUSTOMER APPROVAL LANDLORD APPROVAL AOORESS 2708 Loker Ave. #1 04 Carlsbad, CA 92010 LOCATION ELEVATION 24' SIGNATURE DATE SIGNATURE DATE DATE: 08-15-11 l CONCEPT A 12341 SALES: AQT ~WN BY KL WE HAVE REVIEWED AND APPROVED THE SIGN DETAILED HEREIN TO BE FABRICATED PER THE SPECIFICATIONS SHOWN ON THE DRAWING i a:aa i~I GN S Gr@~~iV@ ~r~PhiC ~@li.UMC9:n& L 7923 Warner Ave. #M Huntington Beach, CA 92647 (714)848-9616 Phone (714)203-9690 Fax . (7) ~} (s} Thrss.gn•~IObe iMialod In occonlonco -I PAGE lhe ~ oi Attk. .. IOioflheN~Eiectrk.al c--..---2 klc:M codes Thcs lnc.lodes proper ground•ng end OF _ ........... Contractors lie. J I 2 #917099 Website: www.i2isigns.com Email: i2isigns@gmail.com COMMENTS: OJ ~l~ m [[) SCALE: 1 /8" = 1 I NOTE: This is an original drawing, created by i2i Signs Corp. It is submitted for your personal use in connection with a project being planned for you by i2i Signs. It is not to be show to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion. Any printed colors on drawing are approximate. - File Edit View Favorites Tools Help