Loading...
HomeMy WebLinkAboutPS 2016-0010; MAXLINEAR; Sign Permits/Programs (PS). , REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PLANNING APPLICATION# ~ 2.0fl.,(1' I 0 . REC'D BY Avrrto,1 z1l,,f, DATE 114·1At1b SIGN FEE b~ -"° SIGN PROGRAM FEE ________ _ RECEIPT NO. __________ _ All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks Name of Project: t1,A)( l, I fJ tA R.. Address of Project: 59(,a <a V\, PLAa Cr, Assessor Parcel Number: _______________________ _ Related Planning Case Number(S): ___________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel (g) (El Commercial (e) Service Station (h) ~ Office/Industrial · (f) Prof. Care (i) SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Theater Gov't/Church/School Public Park U) . Produce Stand (k) Nursery (I) P-U/OS Zone Yes □ NoC81 Specific Plan Number ____ _ VILLAGE REVIEW AREA (If ves. please complete information on page 3) Yes D SOUTH CARLSBAD COASTAL REVIEW AREA Yes □ No □ No □ SIGN ORDINANCE: Yes □ No □ COASTAL ZONE: Yes □ No □ P-11 Page 1 of4 Rev. 10/13 , 4 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole . Monument Wall I ~40 z. .... _ 6 Q Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes~ No O Date ------'---- PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Pole** Monument** Wall I zo.o z---~'/ Suspended/Projecting Directional C!l.nopy Freestanding*' (Project Identity) Digital Display PROPOSE.D TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 10/13 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I ' I ' PIL • Sight Distance Requirement • I l I Show building ls : i I I ' I ! '---~i Show setbacks from all curbs ---: ' I I ' ' I I Show all property lines ' PIL , I : I • I curb line . I ----------~--- • • Si,ht Vin'bility Street Name(s) (i) I ' North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: _________ sq. ft. Total Building Street Frontage: linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: ________ sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 10/13 • PROPERTY OWNER NAME PRINT OR TYPE MAILING ADDRESS CITY STATE . ZIP I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. APPLICANT NAME PRINT OR TYPE MAILING ADDRESS CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF Y KNOWLEDGE. l. IZ. DATE 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route cop'f1Jf.8YJ Ent!)' APPROVED: Planner: ~t; Date: 1r(~/;. L P-11 Page 4 of 4 Rev. 10/13 ► AXLINEAR Design # 16-262 Date: 4-21-16 R1 -6/1/16 SMC R2 -6/29/16 SMC DATE - NANMNG~ tit£ fl \'~11\ BUILDING {.__ ----------:::::j Carlsbad, CA Sierra West Company 2958 Ceylon Dr. Costa Mesa, CA 92626 Telephone: 714-227-7891 I ·r-r-rr: ··-t I j t i I ':t •~-t • . • l,f--, f • • . -... .. . . /1 / I .. :1 ~ ~ . l ····l!.!.A, .' •• ,k;. ,.~ ' . . lilCJ I I ! ' 1 l ' • ~ n;-i ! ':i liiJ I I I I I I , I' . l I I I • I i I r ; lml [ I f I I ' I fi~'dl ~:..c.l~_I , •• ..:.._ F~~~; FLOOR PLAN /N" Site Plan CLIENT/ JOB SITE Maxlinear 5966 La Place Ct. Carlsbad, CA PROJECT Date: 4-21-16 scale: Noted designer: SMC account rep: SMC E DES~_GN# ? _ 16 ---) ~::::=== 262 --REVISIONS R1 -6/1/16 SMC R2 -6/29/16 SMC APPROVALS Customer: _______ _ Salesperson: ______ _ Landlord: _______ _ NOTE: By signing the above line, you are approving all color, size, and materials as well as location of all said signs. This is an original unpublished design created by Sierra West It is NOT to be shown or exhibited to anyone outside your organization Reproduction or construction of displays based on this design is subject to legal actions. Sierra West Company 2958 Ceylon Dr. Costa Mesa, CA 92626 Telephone: 714-227-7891 NOTE: Existing electrical will be extended using weather tight connections and conduits to new sign location. NOTE: Any repairs needed to building where existing sign is to be done by others after new sign work is completed. Existing Sign Location to be removed Superimposed Photo Elevation of New Location Scale: 3/32" = 1 '-0" CLIENT/ JOB SITE Maxlinear 5966 La Place Ct. Carlsbad, CA PROJECT Date: 4-21-16 scale: Noted designer: SMC account rep: SMC E DESIGN# 16-262 REVISIONS ~ R1 -6/1/16 SMC R2 -6/29/16 SMC APPROVALS Customer: _______ _ Salesperson: ______ _ Landlord: _______ _ NOTE: By signing the above line, you are approving all color, size, and materials as well as location of all said signs. This is an original unpublished design created by Sierra West It is NOT to be shown or exhibited to anyone outside your organization Reproduction or construction of displays based on this design is subject to legal actions. Sierra West Company 2958 Ceylon Dr. Costa Mesa, CA 92626 Telephone: 714-227-7891 8" Ill :: ' _; .., ~ ~ C ~ .2 ~ Total Sign Sq. Ft. = 60.00 [tl 16'-0" ,_0,, ... I +--Top of Roof b -· ,,, I I l -·~ .. _ l ~ _ _ H _ . , _ · 11 ~ _ _ _ _ _ II I _ _ _ _ i ~ N-Alumlnum .o:¥4---. I ==~~KP-&-r :--. ·w»:~:J.,Wj{,· f I··· ~~~ --"44,-,k;;,,~ fc:-L';_., '. -0 .i)1<~. ~ ~~in~~s~~-~- MAXLINEAR} INC.~~ < -, •· "" 0 o_.,_ WWW db """"" ~-™2, ™ """"""' .. , ' . t ii N Non Vision Glass ,_ ___ New Bru■hed Aluminum Background Window Mulllon L :-7 ~~-;.-)•-~~--.,;. f:-_....., -g.-. ,.,.--:-:.. ., -~_,.--~"1,v:-· # .. _.-r""?'i'-~, :-:~~::-. ._ \ . . . . Vision GIHS Existing Sign to be reused New Fabrication to be added to match existing sign 1rabricate and Install One set Halo Lit Channel Letters on a Parapet Frame Brushed Aluminum Background 1511'1!1: Scale: 3/8" = 1'-0" Use standard aluminum construction with Matthews satin acrylic polyurethane finish "MAXLINEAR, INC+ Logo" (Reverse Pan Channels) Paint faces & Returns black illuminate with white LED halo .125" thick flat cut out aluminum backer with brushed aluminum laminate overlay. Install on aluminum Sq tube frame painted silver NOTE: see next page for side detail CLIENT/ JOB SITE Maxlinear 5966 La Place Ct. Carlsbad, CA PROJECT Date: 4-21-16 scale: Noted designer: SMC account rep: SMC ( o~:~GN# ) 262 --REVISIONS R1 -6/1/16 SMC- R2 -6/29/16 SMC APPROVALS Customer: _______ _ Salesperson: ______ _ Landlord: _______ _ NOTE: By signing the above line, you are approving all color, size, and materials as well as location of all said signs. This is an original unpublished design created by Sierra West It is NOT to be shown or exhibited to anyone outside your organization Reproduction or construction of displays based on this design is subject to legal actions. Sierra West Company 2958 Ceylon Dr. Costa Mesa, CA 92626 Telephone: 714-227-7891 Sign B Details LINE THE INSIDE OF TUBE FRAME WITH 2 3/4" . 3M ANTI CORROSION TAPE TO 7-1 }~ 112J PREVENT METAL ON METAL CONTACT 9" ~ ACCESS DOOR @ TOP OF RACEWAY W I 1~ POWER SUPPLIED MOUNTED IN TOP I '( _L PORTION OF RACEWAY NOTE: LOW VOLTAGE TRANSFORMER INSIDE HOUSING / RACEWAY SIGNAGE TO BE INSTALLED w/ WATERTIGHT ROOF MOUNTING MATERIAL HARDWARE & EPOXY. --1 1/411 x 1 1/411 x 1 1/4" DIA. END VIEW RUBBER BUMPERS w/ THREADED STUD ALL COMPONENTS -UL APPROVED PRIMARY POWER TO BE PROVIDED WITHIN (5) FEET OF EACH SIGN LOCATION. <i ■ a:1•1111 l:l • ·I· (1) 120 Volt Circuit 20 AMP CLIENT/ JOB SITE Maxlinear 5966 La Place Ct. Carlsbad, CA PROJECT Date: 4-21-16 scale: Noted designer: SMC account rep: SMC E DES~_GN# ? _ 16 ---) --~=== 262 --REVISIONS R1 -6/1/16 SMC R2 -6/29/16 SMC APPROVALS Customer: ______ _ Salesperson: ______ _ Landlord: _______ _ NOTE: By signing the above line, you are approving all color, size, and materials as well as location of all said signs. This is an original unpublished design created by Sierra West It is NOT to be shown or exhibited to anyone outside your organization Reproduction or construction of displays based on this design is subject to legal actions. Sierra West Company 2958 Ceylon Dr. Costa Mesa, CA 92626 Telephone: 714-227-7891