Loading...
HomeMy WebLinkAboutPS 97-62; East Coast Bagel; Sign Permits/Programs (PS)JUL-23-97 WED 10 : 40 CITY OF CARLSBAC COTIM DE FAX NO, 4380894 P, 02 ,c City of Carlsbd 2075 tas Palmas Drive Carlsbad, CA 92009 (619) 438-1 161 MFEE -- c All plans submitted for sign pc-rinidsign program shall hmsisi uf a minimum of a site plan and sign elevations cofitaininp the %ikmiq ixlfkixatiGiL. 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas. and vehicular RCCW. points to the property. 3. Locatiori of all. existing and pmposed sips for the property. 4. Distance to the propeq linc(s> for dl proposed frerstanding signs. 5. Provide an elevation fcr all proposed signs which specifies the foliowing: , A. B. C. Prvpvsed sign copy. Dirnensiom ar;d area for all existing and proposed signs. Materials the sip(s) wil! be ccmstmcted of, APPLICANT hlGST SUBMIT THREE (3) SET’S OF SIGNISTII’E PLANS, A COMPLETED APPLICATION FORM, Aha THE APPLICATION FEE. SIGN TYPE: @ Commercial (b) Industrid (c) Residential (d) Real Estate (e) Freeway (f) Marquee (g) Comrnuniry identity (h} Service Stn. Prices (i} Campaign SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes YO - SPECIFIC PLAN NUMBER SIGN ORDINANCE: Yes- NOJ COASTAL ZONE: - NU AOASTAL. PERMIT Yes - KO / FRMOOO 1 0 2/96 Page 1 of 2 JUL-23-97 WED 10: 40 CITY OF CARLSBAD COMM !jE 'FAX NO, 4380894 P, 03 EXISTING SIGNS: 'Ttpc Number - Size (in square feet] - - (a) Pole (b) Monument - (e) Wall - - - PERMITS ISSUED FOR EXISTING SIGNS: Yes .L- No - Aare TOTAL BUILDING STREET FRQNTAGL: TOTAL SIGNAGE ALLOWANCE EXISTING SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AT PRESENT PROPOSED SIGNAGE (SQ. FT.) REMAINING SIGN ALLOWANCE AFTER PROPOSED SIGN e- sq. ft. 13 .E5 sq. ft. 12. sq. ft. IT. 6 sq. ft. KAME (PRINT OR TYPE) NAME PFUNT OR TYPE) MAILING ADDRESS MAILING ADDRESS CI?3 AND STATE ZIP I CERTIFY THAT I AM THE RFPRESENTATNE OF THE LEGAL. OWNER ANn THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT M WE BEST OF AND mri~ .u riiE MOVE INWRXATCN 15 TRUE rvJU CORREt.3 TO Tklb BEST OF MY KriOwLEDGE MY ICFiOwLEDGE SIGNATURE DATE PLANNER CHECK LIST: 1. Ficld check by planner. W 2. Within iim.imurn lengrh, area. 3. 4. Location: In right-of-way Style consisrent with Sign Picgram anS'c; Specific Plan criteria, if applicable. In visibility triangle at corner On rvvf 5. 6. Pole and monurneni signs to be checked by Sob Jchson, Traffic Engineer, for visibility issues, When approved route copy ro Data Entry APPROVED: Planner: Date; 7-a=-57 FRMOOOXO 8/92 Pagc 2 of 2 I I I , ! I I ~ I I I ! i ~ 1 I '.',. Listed sign section (consists of channel leller, plaslic face, tube supports, and glass cup or insulating bool, if provided) suilable lor outdoor location unless marked for indoor only. --+ 7 Recognized component. Plastic face provided with sign. c\ Tube support ~ I Neontube. I .,.. per NEC 600-33(b). Spacings maintained per spacing table. I: Mechanical connedion (lwisled , ', surface lo lube connection. Letter OK, See dwg C2 for assembly , height instructions). I-? in. minimum varies clearance through air or across cup shown, no required spacing). I See dwg C3 for assembly inslructions. NEC 600-34(b) glass cup or insdating boot (glass Or 1 SPACING TABLE A. Between primarywiring and insulated high vollaw wiring. B. Between insulated high voltage wiring and dead metal where wiring parallels dead metal for more than l'wilhin sign sections. C. Between neon tube (il over 75OOvolt circuit) and nearesl suiface. 0. Between uninsulated high vollaue conductors or components. (Mid- point-groiinded transformer) and dead metal (ground), low voltage circuit conductors and hih voltacie conduclors of omosite oolaritv. Fasteners as required by the local jurisdiction. Primary electrical source (1/2 in. minimum conduit, metal shown) NEC 600-6 L 600-2 1. Depth varies 14- Drain holes if used outdoors. Wall varies in thickness and material / isting marks: Listing mark siun section leltol shall be on each leller and transformer enclosure. The first blank space identifies the I number of each sign seclion. The second blank space Indicates I Ihe Iota1 number of sign sections. - - .. .. - Listed disconnect switch in primary to be within sight (maximum 50 It.) of sign. mrrI (Many interpret transformer enclosure 1001 to5000 1Rincii 1Rinci- none 3/4in to be part of sign.) NEC 110-3(b), 600-2,600-4 5001 loloo00 34inch 3/4inch 1Minchil l-l@in 3/8 in. minimum listed flex (metal loo01 to 15000 1 inch 7500Vt 1-1R in shown) and listed GTO cable (secondary A- side onlv and to the next section letter). . NEC lli)-3(b) 8 600-31. Spacings maintained per spacifig table. Lislodaign seclion (consists 01 transformer and enclosure) suilable lor outdoor locations unless marked for indoor only. Accessible. NE0 600-32(e). Grounded enclosure. , , '- Fasteners as requi[@d by local jurisdon., V Bonding jumpers (minimum No. 14 copper) required if; (1) flexiblq metal conduit in ground return path exceeds 6 H. (NEC 350-5 Exc. No. 2), (2) conduit is nonmetallic, and/or (3) electrode receptacle uses gaskets NEC 110-14(a), 250-43(g), 250-79(f), 250-97,250-113 & 600-5. / that will impair ground return path or direct melal-to-metal contact. All iylhls ieserverl. No pail ul 1111s work cuvared by 11ie cnpyiwhl hereon niay be laproduced or used in any foini ui by any iiieaiis . arapliic. sleclicins. 01 LISTED by qualified electrical .. .. testing laboratory ELECTRIC SIGN SECTION NO. XX-123456 ~--, , ... . ..-, .. .- .- -. Diiblisher. iiachantal, including pholocopyiiig. recording. laping. or .iiiforiiialion slotage aiid reliirval sysleriis . williaul wiilleii perinissioii of Ihs publisher. excepl lhal siiigk cnpiis of iidivitlual pwss inay be matla by a bona lie elediical sign installalion firiii lor Ilie sols piiposa of providing guidance on llie iiislallalion of elecliical sipiis ai oulliiie lighliiiy. without the periiiissioii 01 llie lnslallation of siuns listed per U148 Nole lnslallaliori requirements only. ManufacturinU requirements contained in UL48 __ __ I -- ILLUMINATED CHANNEL LETTER WITH ENCLOSURE SIGN FACE Scale None . . - - . - - ____ ____ Date: October 1994 c Dwg. IAEl No. u44e-T1A I n'-2 1/2" I I I I iTi"t 12'-0" 1 I SIDE VIEW ELEVATION: STOREFRONT RACEWAY CHANNEL LETTERS & LOGO. * CUSTOM FABRICATED STANDARD S/M CHANNEL LETTERS & U3GO 5" DEEP MOUNTED ON RACEWN PLATFORM 5 1/2" DEEP HOUSING ALL ELECTRICAL COMPONENTS, WIRING, TRANSFORMERS & ELECTRODE HOUSINGS. RACEW!! PAINED TO MATCH BEAM ABOVE. * LETTER, LOGO RETURNS & TRIMCAPS PAINTED MATTHEW ACRYLIC POLYURETHANE DARK BRONZE ANODIZED FINISH. * LETTER FKES TO BE WHITE ACRWTE ACRYLIC W/ SURFACE APPLlED 3M TRANSLUCENT TEAL #230-246 OVERLAYS. * LOGO FACE TO BE WHITE ACRYUTE ACRYLIC W/ SURFACE APPLIED 3M SCOTCHCAL COLOR VINYL FILMS W/ AIRBRUSHED YELLOW BACKGROUND TO MATCH ESliSBUSHMENT. * LIGHT SOURCE TO BE 13MM 6500 WHITE U/L LISTED NEON GAS SYSTEM ON 30MA N.P.F. REMOTE TRANSFORMERS. DRAWING #A6273 CUSTOMER APPROVAL 8IoEI-mPs 9743. I II II - f / H H / ! / R R i i 1 I T1